Loading...
24A-166 (7) BP-2024-0511 319 PROSPECT ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24A-166-001 CITY OF NORTHAMPTON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2024-0511 PERMISSION IS HEREBY GRANTED TO: Project# chimney liner 2024 Contractor: License: Est. Cost: 3480 CORY MCGILL 107658 Const.Class: Exp.Date: 05/25/2025 Use Group: Owner: BIXBY BIXBY NATALIE A&GEORGE F Lot Size(sq.ft.) Zoning: URA Applicant: CORY MCGILL DBA DONE RIGHT CHIMNEY Applicant Address Phone: Insurance: PO BOX 1054 (413)340-1399 WCV 01525601 WILLIAMSBURG, MA 01096 ISSUED ON: 04/26/2024 TO PERFORM THE FOLLOWING WORK: INSTALL CHIMNEY LINER POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: 1,4"2. Fees Paid: S65.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner The Commonwealth of Massachuse is I* . Board of Building Regulations and St. 'd FOR MU Massachusetts State Building Code, 780 CIAS c902 NICIP LITY Building Permit Application To Construct,Repair,` .ete Or Demol}'Sh a Revised Mar 2011 One- or Two-Family Dwelling'' n''''�,n R._ / This Section For Official Use Only ._n,,,F0CNs Building Permit Number: ge''.2`f� J�// Date Applied: 7,1Z5 //7 26-2ozy Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map& Parcel Numbers 319 Prospect Street, Northampton, MA 01060 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private CI Municipal_ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: George Bixby Northampton, MA 01060 Name(Print) City,State,ZIP 319 Prospect Street (413) 345-8626 georgebixby@comcast.net No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition ❑ Accessory Bldg. 0 Number of Units Other 1E1 Specify:Chimney re-line Brief Description of Proposed Work2:To install(1)5"316 stainless steel liner kit in existing masonry chimney to vent existing oil burner.Level 2 inspection completed on 03/11/2024. SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $3,480.55 1. Building Permit Fee: $ Indicate how fee is determined: ❑Standard City/Town Application Fee 2. Electrical $ ❑Total Project Costa(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Suppression) Total All Fees: Check No. 1O' (Check Amount: W-' Cash Amount: 6.Total Project Cost: $3,480.55 0 Paid in Full 0 Outstanding Balance Due: • SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-107568 05/25/2025 Cory McGill License Number Expiration Date Name of CSL Holder P.O. Box 1054 List CSL Type(see below) U No.and Street Type Description Williamsburg, MA 01096 U Unrestricted(Buildings up to 35,000 cu.ft.) City/Town,State,ZIP R Restricted 1&2 Family Dwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances (413)340-1399 ContactDoneRight@gmail.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) Cory McGill #178722 08/27/2024 HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name P.O. Box 1054 ContactDoneRight@gmail.com No.and Street Email address Williamsburg. MA 01096 (413)340-1399 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ® No .0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Cory McGill to act on my behalf,in all matters relativeiv to work authorized by this building permit application. Leo txb Jo 7 s i3,2t 20:59 CDT) 04/23/2024 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER1 OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this appli tion is true and accurate o the best of my knowledge and understanding. Cory McGill 04/23/2024 Print Owner's or Authorized Agent's e(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" JNSTALLATION INSTRUCTIONS Phone:888-900-8106 FOR BEST-Flex Models "L", "H", "S", & "E" Fax:888 392 4432 STAINLESS STEEL CHIMNEY LINERS Web:www.NewEnglandChimneySupply.com 34 Commerce Street,Williston VT 05495 BEST-Flex Models I LiH19 ii�7! & LLE7! HEST FLEX New England Supply PRODUCTS STAINLESS STEEL CHIMNEY LINERS BEST-Flex Models"L","H","S",&"E"Stainless Steel Chimney Liners are manufactured by New England Supply Inc.Located in Williston,VT. The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys.BEST-Flex liners are used to vent the gases and by-products produced by appliances that bum oil,gas,or solid fuels. All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance. The installer must contact the local building and fire code officials for a variety of reasons: • The installation may require special inspection requirements. • Building permits may be required before installation. • Compliance with local building codes.(Authorities with local jurisdiction such as Inspectors,Municiple Building Departments,Fire Departments,and Fire Bureau's have precedence over national codes). For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials not specified may result in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not followed BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories. • In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys. • In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys. PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS • The BEST-Flex Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new construction. Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation.BEST-Flex can be used to vent wood,wood pellet,coal,non- condensing gas and oil,making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available in 3"to 12"diameters (13"above is not listed)to cover a wide range of requirements found in the field today. • The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel,7-ply interlocked and crimped to produce a gas and water tight lining system of superior strength and durability.BEST-Flex can be curved to go around offsets in chimneys and can be factory ovalized to custom sizes to fit most any installation requirement.Unless specified by the manufacturer,the liner is not to be field ovalized. The corrugated construction allows for expansion&contraction during the heat-up&cool-down periods,which removes any stresses on the system. • BEST-Flex can be insulated with either a vermiculite based poured insulation or with a foil-faced ceramic wool blanket to meet UL 1777&ULC S635 standards for chimney exteriors with zero clearance to combustibles. • BEST-Flex Stainless Steel Chimney Liner comes with a Life Time Warranty for all fuels,with appliance efficiencies at 83 percent or lower. MATERIALS REQUIRED FOR BEST-Flex STAINLESS STEEL LINER INSTALLATION: Liner Model-"L","H","S",&"E" • TT/TB-Two piece or one piece tee TEC-Tee Cap EA/EF-15°-90°elbow C/CC-Coupler ; • Screws/Rivets z OPTION A OPTION B TP-Top Plate TPCC-Liner Cap TC-Top Clamp 10Ir 0 OR TPC-Top Plate OR SC-Storm Collar CL-Liner Cap(square/round) INSULATION MATERIALS REQUIRED(if applicable) Part# Description LI2 Liner Insulation 1/2"Foil Faced Ceramic Wool Blanket LM Liner Mesh Protective Wire Mesh Sleeve FT(2",3") Aluminum Foil Tape Cjd► -. +r,> LMC(large/small) Mesh Clamp BMIX BEST Mix Phone:888-900-8106 -, Fax:888-392-4432 � ; Web:www.NewEnglandChimneySupply.com New England Supply 34 Commerce Street,Williston VT 05495 1.)CHIMNEY PREPARATION&INITIAL INSPECTION Before any liner can be installed the existing chimney must meet proper construction and code requirements: • The chimney must be between 10-ft high(min)and 100-ft(max)in height. • The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit. • The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius. • If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any combustible material.If the chimney is constructed on the outside of the structure,1-in of unobstructed air space must be maintained between the chimney mass and all other combustible materials. • When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used. • The installer must verify the above with at local&national codes as required. • If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material. • Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance. • The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence. • The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full inspection must be done to determine if the chimney is structurally sound. If the existing system is found not to be in compliance with applicable building code and/or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring the chimney or vent into compliance with the applicable code and/or manufacturer's instructions. Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any applications that require a vent or chimney of a higher temperature handling capability,an alternative fuel,or any other more sever service than the original chimney or vent in which it is installed. CHIMNEY CONNECTORS AND VENT CONNEcwIms 2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER • kYdmen:7....amass•_• Syshem A.Wm.3 5".(90 mm)0ee*brew masonry stab I,anwl.10 Any heating appliance connected to the lining system must not bleardmo-aelw,� ,,tapt gena-elnel0012n1305maoreseora 2te.(st rant es..aa eYrnxn deem. hnm Coy finer b c;ni>,rsteees Poeday Ina 10.5TIA C 015 have a flue outlet size larger than the liner area at its smallest h. re ae ^* StaWarasc x�0010,ClayFluebatesariac mney�.oraa,n�1). point,unless aqualifiedperson has sized the liner to suit the .ot n arum t,"a6naruwa20 ram Winn.horn cuter T aere�eaan but ndbooed the inner so edv..�w. appliance �' , _...... .end woeerr.,wmented.,baee • For sizing a liner used for gas and oil burning appliances refer L " au, is des m 12n t305o n1 to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the „r,.,2b/xsaml es ' Raw appliance manufacturer's instructions.Liners that are incorrectly bwnmete. r aoeetoSFR%Tit sized for the appliance can lead to poor draft,excessive condensation,and creosote build-up inside the lining system. 1AYii...dimes Ow Sy.umB.SoaTins.:aroe Peed fact«rboalchnvay of the see. \ ..�>.e es awl OW swore we erreras aside 2enek'ast Wnne,'CGn M✓and twins 1 i; m.oaiees1e.(51mr I•1.' tang: 125sw)sr mare d:ns,:aton rt..a mnenurr 9 to r229 arm) Please call New England Supply Inc.should you have any ■ sr xaa..m spec odwe0n to cuter coos of me dam00V length and questions about sizing a liner. (i.Nm.y� "'""O1i -r .my cont„s,.*s daanl'lar�l dead / WradA The inner end Oldie chimney length stag be rush.Yarn me • For sizing a liner used for solid fuel burning appliances the cross ewe a Use maanmaemneynua and shall be sealed todlenae section area of the liner shall not be less than the cross section mr r are. andtothebc masonry penehaeanwa'non'oate`saa,le i d Ia. I use Barley tdretary cement Supports anal be secvdy twinned to wall i•.:•.•i..':•. ,.mya.temb .url0M,on es odes. area of the appliance outlet collar.Unless specified by the r� a ,\ eleneamemr Fasteners Cense. .Poorts and taasrw,eylengtsnadnot appliance the cross section area of the flue shall not be more than (, Se Mg mends i \yy. penetrate me wnrey bran three(3)times the cross section area of the appliance outlet collar. „efin, tam i.yearvirt a•.4m:3 in.(Ma mm) Solid fuel burning fireplace liners should be a minimum of one- geerrrwrte twelfth(1/12)the square inches compared to the square inches of the fireplace opening.This one-twelfth(1/12)number can i.Mwmdenay amerce br,M Mn—i, sy.a nromle mc.Sneelsteel ,.onneotns mows M 24 gauge 9.024 i, .mr.rgwrbad,nIt tles le.51 marl)In twckre55.with a ventilated tumble.Thorium vary based on height of the chimney along with other calculating zn tsle.nl a I twee sawed 24 gauge 1002am f061 no0 m eadmess hay yMo 1 n factors.Call New England Supply Inc.ifyou have anyquestions. r "e "'�""' 25mm1 a separatedbo " ".>�^ -.mum 9 PP Y ry `� IJ and 52 t0 glass She a. .n1.ins~gbeco.er19 F/ ,t aims and hr..supported Y, sneer ,eelsaWo ,2d ga.ga / 1 m"'" 10 Ala g6t 1 POCK,. \S /// �l Supports anal be securely fastened.o wag sur•aces on ae des 3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT INTO y andsnal oesizedtoStandhuldenm,,,eysor Fasteners .a1 THE CHIMNEY ,' Ye In le secure cremes sonbo snoun«oanpmaroeennayapama ie..r1a.ar °00 nreron Our e,rn.e.ere 1 le Geaasre Sin.(152 fret) • The BEST-Flex Stainless Steel Chimney Liner can be installed tei25e.e1: rrre+y inside the existing flue tile or the flue tile can be removed.It e;n s"ao d °° tl"b "211 Slueleatpoo,t• is critical that the correct size liner will actually fit into the flue. Chimney construction and flue offsets may change the physical ,.,ame.s..yderrr,b.reetsnel swan in/ System D.Sokl4roulalid,mod tactory-buActsmnsyleng9..wehanmsde m*0 e2n.ts1 em). darner 2M.(51 ram)laver Man Me&lorey connector and haying size of the interior of the chimney.It is best to test the smallest ,et(2s mm)pmlmae apeson se pas apasam wgn bra sex}e point of the chimney interior before trying to install the chimney womb as•ez+rar..ame.r.m2"(s'"" lee'm)i*°'"eo."yaaosmium241 t I an)airgpoeuar i0b1 mmll ,we,a osmium 2+,.(St an)as space barmen the 'ps..ml.or. outer well elAierney 0*a anm rs, 0lbosa liner.Lower a short piece of the correct size liner down the ,ra ==�• "�-•� *me mlmpofarm eysects. Obe12n.1306 rent Clymer/ chimney to see if it will fit through,or a liner guide cone.If the s.pr"'canoed.wie'and spaced I (25mrel away bow a"oed.by ' Calmat mans d sleet steel supper!,Metes on born ends d deanery secaon chimneyliner needs to be insulated extras ace around the liner 0.....0. —t °prom° be covered.and dstmesstrew supported on both sales eh P mnrw Wool Msd supports of mamba.24 gauge 10024 in(001 Mtn Insides, Supports anal to sec/rats ladoned to set s,:r'aces on al s des is required.If a round liner configuration will not fit the liner can be ,y�e2in(51me) e. _y manor— and War be sired te01 and bolo Onnaysect,n Fasteners us. formed into an oval shape to fit at the factory. However an oval te.rwtra Saw as"stew. re secure crerrs,sew,.sh,t rornetale thresh fins ane' liner will change the cross section area and a larger liner may be rr tea, 2'1 Ceara,.2 n 151mra needed.Please call New England Supply Inc.with any questions. Note Alt deanrms and art messes are mmomass,larger clearances and M,cknesses are peaked. 4.)INSTALLING THE BEST-FLEX STAINLESS STEEL CHIMNEY LINER • Thimbles must be in the proper location to maintain the required clearance to combustibles from the connector pipe to the appliance. The liner length is determined by measuring from the lowest thimble(if more than one)to the top of the chimney.Add approximately Six(6)inches to attach the crown and top hardware.Cut the liner to the desired length. • If a liner is not long enough a coupler may be used to join two pieces of liner.Attach the Coupler to the liner with the affixed band,or stainless steel screws(Male end down when applicable). • Attach the Tee Body to the liner with the affixed band,or stainless steel screws. If the liner needs to be insulated with a ceramic wool blanket,install the blanket at this point. Attach the Tee Cap to the Tee Body at this point. • Expand the draw band on the Tee Snout completely,slide the Tee Snout into the thimble with the draw band centered in the flue.Lower the liner The Commonwealth of Massachusetts r Department of Industrial Accidents — Office of Investigations 1 Congress Street, Suite 100 • 1i{= Boston,MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name: Done Right Chimney Address:P.O. Box 1054,49 Main Street,#4 City/State/Zip:Williamsburg, MA 01096 Phone#:(413)340-1399 Are you an employer?Check the appropriate box: Business Type(required): 1.D I am a employer with 9 employees (full and/ 5. ❑■ Retail or part-time).* 6. ❑ Restaurant/Bar/Eating Establishment 2.❑ I am a sole proprietor or partnership and have no 7. ❑Office and/or Sales(incl.real estate,auto,etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8. El Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4),and we have 10.❑ Manufacturing no employees. [No workers' comp. insurance required]** 11 ❑Health Care 4.❑ We are a non-profit organization, staffed by volunteers, with no employees. [No workers' comp. insurance req.] 12.0 Other Services: Chimney&Hearth *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name:Atlantic Charter Insurance Company Insurer's Address:49 Main Street,#4 City/State/Zip: Williamsburg, MA 01096 Policy#or Self-ins. Lic. #_ \(Y C�O 15 p►3 Z OO Expiration Date: NI i i 011,0 i 5 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify,under the pains andC penalties of perjury that the information provided above is true and correct. Signature: qiY1YVl/ Date: C Li)/Si?y Phone#:(413) aj\ --1399 UUU ___ Official use only. Do not write in this area,to be completed by dry or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.mass.gov/dia