32C-017 (7) °1pT°ti City of Northampton REQUIRED INSPECTIONS ��'-'•1` )A 1 . Footings and Walls it,"-� BUILDING DEPARTMENT 2 . Structural Components in Place 3 . Complete Building No. 538 Office of the Building Inspector Date Septmeber 20, 1991 19 BUILDING PERMIT THIS MAY CERTIFY THAT VRC ASSOCIATES/David Fogel Insp. on Site — Foundations has permission to Repair existing steel fire escape Insp. of Plumbing — Rough situated on 78 Main Street Insp. of Plumbing — Finish provided that the person accepting this permit shall in every re- Insp. of Wiring — Rough spect conform to the terms of the application on file in this office, and to the provisions of the Statutes and the Ordinances relating Insp. of Wiring — Finish to the Construction,Maintenance and Inspection of Buildings in Insp. of Health (Septic Tanks) the City of Northampton. Any violation of any of the terms above noted is an immediate revocation of this permit. Expires six Building Insp. — Rough months from date of issuance, if not started. Building Insp. — Finish c "- ,_ Note: A certificate of occupancy will be issued by this office upon return of this card signed by the Plumbing,Wiring and Building Smoke Detectors (Fire Dept.) Inspectors. Gas Inspection THIS CARD MUST BE DISPLAYED IN A CONSPICUOUS LA E 0 pT E PREMISES Certificate of Occupancy. / r Building Inspe POP o o City of NorthamptonREQUIRED INSPECTIONS $� ,;.„r:k - 1 . Footings and Walls 'fed:;. BUILDING DEPARTMENT 2 . Structural Components in Plac:===h e 3 . Complete Building No. 538 Office of the Building Inspector Date Septmeber 20, 1991 19 BUILDING PERMIT THIS MAY CERTIFY THAT VRC ASSOCIATES/David Fogel Insp. on Site — Foundations Repair existing steel fire escape has permission to Insp. of Plumbing — Rough situated on 78 Main Street Insp. of Plumbing — Finish provided that the person accepting this permit shall in every re- Insp. of Wiring — Rough spect conform to the terms of the application on file in this office, and to the provisions of the Statutes and the Ordinances relating Insp. of Wiring — Finish to the Construction,Maintenance and Inspection of Buildings in Insp. of Health (Septic Tanks) the City of Northampton. Any violation of any of the terms above noted is an immediate revocation of this permit. Expires six Building Insp. — Rough months from date of issuance, if not started. Building Insp. — Finish Note: A certificate of occupancy will be issued by this office upon return of this card signed by the Plumbing, Wiring and Building Smoke Detectors (Fire Dept.) Inspectors. Gas Inspection THIS CARD MUST BE DISPLAYED IN A CONSPICUOUS LA E O .T E PREMISES Certificate of Occupancy Building Inspe pep UDate Filed September 11, 1991 File No. ZONING PERMIT APPLICATION (§10 . 2 ) , 1. Name of Applicant: V.R.C. Associates Address : 78 Main Street, Northampton, MA 01060 Telephone: (413) 582-1225 2 . Owner of Property: V.R.C. Associates • Address : 78 Main Street, Northampton, MA 01060 Telephone: (413) 582 1225 3 . Status of Applicant: X Owner Contract Purchaser ' Lessee Other (explain: ) 1 ! 4 , Parcel Identification: Zoning Map Sheet# 32C Pa; eel t_17 Zoning District (s) (include overlays) CB Street Address 78 Main Street, Northampton, MA 01060 Required 5 . Existing Proposed by.,_s,ar ing Use of Structure/Property Office/Commercial Office/Commercial (if project is only interior work, skip to #6) Building height 5 Floors 5 Floors %Bldg. Coverage (Footprint) 100% 100% Setbacks - front None None - side None None - rear None None _ �~ Lot size _ Existing Existing -,.. Frontage 58 58 Flocr, Area Ratio N/A N/A %Open Space (Lot area minus building and parking) None None __ _ Parking Spaces None None Loading None None Signs Existing Existin• • Fill (volume & location) N/A N/A _ 6 . Narrative Description of Proposed Work/Project: (Use addit:ici; l .meets if necessary) The existing steel fire escape would be repaired and repainted to ensure that it is in structurally good condition. 7 . Attached Plans : X Sketch Plan Site Plan 8 . Certification: I hereby certify that the information contained herein - is true and accurate to the best of my knowledge./ 41 � eitKe9 •Date: September 11, 1991 Applicant ' s Signature: ! £�/1f aeh=-- THIS SECTION FOR OFFICIAL USE ONLY: JApproved as presented/based on information presented Denied as presented Reason for Denial: • 9 -ao-9/ __ Sigh off" i g Ins or Date NOTE: Issuance of a zoning pc ' oes not relieve an applicant's burden to comply with all zoning requirements and obtain al!ruquircd permits from the Board of Health, naervation Commission,Department of Public Works and other applicable permit granting authoritks. b 70 IIZ 0 A. C MI IW d b 0. r" a © ° n E. - 0 8 G') z °° 7d o b Z EiO CD y tri ~ C Zoning CB Miscellaneous Additions,Repairs,Alterations,etc. Tel.No. Alterations N/A t""""T NORTHAMPTON, MASS. September 11 , 19 91 Additions N/A WV f'I N Repair Fire Escape APPLICATION FOR PERMIT TO ALTER sy Garage N/A 1. Location 78 Main Street, Northampton, MA 01060 Lot No. 32C Parcel 17 2. Owner's name V.R.C. Associates Address 78 Main Street, Northampton, MA 01060 3. Builder's name Ralph's Blacksmith Shop Address 36 Smith Street, Northampton, MA 01060 Fdwarcl L. denary — Architect O6 �3o��gg3 Mass.Construction Supervisor's License No. ( -3- n 33I I 1 Expiration Date 4. Addition N/A 5. Alteration N/A 6. New Porch N/A 7. Is existing building to be demolished? None 8. Repair after the fire N/A 9. Garage N/A No.of cars N/A Size N/A 10. Method of heating N/A 11. Distance to lot lines None 12. Type of roof N/A 13. Siding house N/A 14. Estimated cost:- goy() 1 The undersigned certifies that the above statements are true to the best of his, her knowledge and belief. loge ao-40-deilted I if,;/, ,_,/9„,",,,,7 55" Sig lure o responsibl applicant Remarks The existing steel fire escape would repai ed d r inted to ensure that it is in structurally good condition. Plibil;SIRIP \t7.�Zi� f I AR(:II►TI:(;T INC. August 26, 1991 DIHI CI uH' µR, hnrw❑ AIA l.da'erd I h ndr MA I'HI`l.u'AI' Scope of Work for the Re it of the Existing Fire Escape 1e,1rn.1 bucker.A.LA (1 u,,,,,,;,,,, at 78 Main Street, Northampton, Massachusetts SENII)H AS"K.IATI Srccc.1 Uulwhch.A.I.A AS�UCIAT! Huhard I. Ae�anu Ann Irw'rcn“ Knox Item No. 1 A. The outside edge angle at the fifth landing has rusted badly and should be replaced. The intermediate angle framing to this angle should be welded in place. Item No. 2 A. Additional bolting needs to be added to the main landing knee braces. An additional 3/4-inch (3/4") Hilti ("Hit System C-20") anchor shall be added near the top of each one of these knee braces at an appropriate space from the existing bolts. Item No. 3 A. A new knee brace should be added near midspan of all of the walkways between landings. A new knee brace should also be added to the main second floor landing. The intermediate angles which span to this edge angle which span to this angle which are bolted should be welded at each end due to the poor condition of the existing bolts. Item No. 4 A. The existing horizontal straps from the building to the stair stringers should be replaced with new straps in order to brace the stair stringers, as per the Massachusetts Building Code. 1 of 2 78 MAIN STREET!NORTHAMPTON,MASSACHUSETTS 01060 (-113)58A-722A A 109 CONCORD STREET!FRAMINGHAM,MASSACHUSETTS 01701 (508)872.8373 Item No. 5 A. The bolts of the tread support angles are in bad condition at various locations. To assure safe support, these angles should be welded to the stair stringers. Item No. 6 A. The tread hold-down anchors have rusted out in a number of locations and should be welded in place. Item No. 7 A. The existing railings of the stair sections should be reinforced with new one and thrcc-quarters inch (1-3/4") by three-eighths inch (3/8") vertical bars at eleven inches (11") center to center. Item No. 8 A. The ladder from the ground to the first floor landing shall be replaced with a new ladder that will be mounted to the wall of the building. Item No. 9 A. After all of the structural repairs have been completed, the fire escape should be scraped free of loose paint and rust, and should be repainted with one (1) coat of ferrous metal primer and two (2) coats of oil- based enamel (semi-gloss). 2 of 2