Loading...
87 Henry St - Updated DesignsINSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 87 HENRY STREET NORTHAMPTON, MA 01060 42.315669074,-72.619364686 HENRY STREET R1 SYSTEM SIZE DECREASE / LAYOUT REVISION 1/4/2024 P1 ISSUED TO TOWNSHIP FOR PERMIT 11/14/2023 NO.DESCRIPTION DATE EWALL, WILLIAM TRINITY ACCT #: 2023-07-906546 87 HENRY STREET NORTHAMPTON, MA 01060 42.315669074,-72.619364686 PROPOSED PV SOLAR SYSTEM DRAWING DATE:11/14/2023 DRAWN BY:RM REVISED BY:DMR DC SYSTEM SIZE:4.86kW AC SYSTEM SIZE:3.8kW MODULE COUNT:12 MODULES USED:HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:6266266019 UTILITY METER #:95000913 DEAL TYPE:SUNNOVA R1 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 0 PITCH: 37° ORIENTATION: 218° ROOF 2 MODULES: 0 PITCH: 37° ORIENTATION: 38° ROOF 3 MODULES: 12 PITCH: 18 ORIENTATION: 218 ROOF 4 MODULES: 0 PITCH: 18° ORIENTATION: 38° ROOF 5 MODULES: 0 PITCH: 34° ORIENTATION: 223° ROOF 6 MODULES: 0 PITCH: 34° ORIENTATION: 43° ROOF 7 MODULES: 0 PITCH: 23° ORIENTATION: 308° ROOF 8 MODULES: 0 PITCH: 30° ORIENTATION: 128° ROOF 9 MODULES: 0 PITCH: 30° ORIENTATION: 308° ***NOTE: 2021 NFPA 1 - 11.12.3.2.4.1 PLAN VIEW TOTAL ROOF AREA: 1713.9 FT² PHOTOVOLTAIC ARRAY TOTAL AREA: 247.2 FT² ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 14.4% DC ACUD ep M ***NOTE: ROOF R3 ABUTS AN EXTERIOR WALL WITH A 24" HEIGHT DIFFERENTIAL N S2709 0 13522545 31542.315669074,-72.619364686 12 HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) 1 SE3800H-US000BEi4 BASEMENT OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. R1 SYSTEM SIZE DECREASE / LAYOUT REVISION 1/4/2024 P1 ISSUED TO TOWNSHIP FOR PERMIT 11/14/2023 NO.DESCRIPTION DATE EWALL, WILLIAM TRINITY ACCT #: 2023-07-906546 87 HENRY STREET NORTHAMPTON, MA 01060 42.315669074,-72.619364686 PROPOSED PV SOLAR SYSTEM DRAWING DATE:11/14/2023 DRAWN BY:RM REVISED BY:DMR DC SYSTEM SIZE:4.86kW AC SYSTEM SIZE:3.8kW MODULE COUNT:12 MODULES USED:HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:6266266019 UTILITY METER #:95000913 DEAL TYPE:SUNNOVA R1 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITY AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 2 CCC: 1.00 (40*.96)1.00 = 38.40A 38.40A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 16.00A*1.25 = 20.00A AWG #10, DERATED AMPACITYAMBIENT TEMP: 30°C, TEMP DERATING: 1.0 RACEWAY DERATING <_ 3 CCC: N/A 40A*1.0 = 40A 40A >_ 20.00A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL INVERTER CURRENT: 16.00A 16.00A*1.25 = 20.00A --> 20A OVERCURRENT PROTECTION IS VALID ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2023 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP = 33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTEDTO OPERATE WITH UNGROUNDED PHOTOVOLTAICSOURCE AND OUTPUT CIRCUIT PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤ 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.) DISCONNECTS FED BY SUPPLY-SIDE SOURCE CONDUCTORS SHALL BE BONDED AND CONNECTED TO GROUNDING SYSTEM IN ACCORDANCE WITH NEC 250.24 12.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BELOCATED WITHIN 10' OF THE POINT OF CONNECTIONNEC 690.9(A)(3)(2) 13.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(B)(2) 14.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 15.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING NEUTRALM 2p200AMAIN240V 1Ø 200A MAIN BREAKER 200A BUSBAR NEW 120/240V UTILITY METER NEW MAIN BREAKER LOAD CENTER 2p20A BACK FEED BREAKER NEC 705.12 E SQUARE D DU222RB 60A UNFUSED DISCONNECT ISOLATED NEUTRAL 240V 1Ø B NOTE: INTERNAL REVENUE GRADE MONITORING CONTAINED WITHIN SOLAR EDGE INVERTER SOLAR EDGE PN. RWND-3D-240-MB INVERTER #1 - SE3800H-US000BEi4 DC AC Imp 10.5 Pout 3800 Vmp 380 Imax 16 Voc 480 OCPDmin 20 Isc 15 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) Imp 10.83 Vmp 37.39 Voc 45.34 Isc 11.17 A #6 THWN-2 TO GEC B 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C NEW 4/0 ALU SEU CABLE D 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-D SOLAR MODULES MOUNTED TO ROOF ON 1 ARRAY 12 - 405W MODULES W/ 1 SOLAR EDGE S440 PER MODULE 15 ADC MAX PER STRING 1 STRING OF 12 MODULES IN SERIES - 380 Vmax *TERMINATED INSIDE INVERTER 1 f 8"x8" JUNCTION BOX NEW 120/240V SERVICE RISER C R1 SYSTEM SIZE DECREASE / LAYOUT REVISION 1/4/2024 P1 ISSUED TO TOWNSHIP FOR PERMIT 11/14/2023 NO.DESCRIPTION DATE EWALL, WILLIAM TRINITY ACCT #: 2023-07-906546 87 HENRY STREET NORTHAMPTON, MA 01060 42.315669074,-72.619364686 PROPOSED PV SOLAR SYSTEM DRAWING DATE:11/14/2023 DRAWN BY:RM REVISED BY:DMR DC SYSTEM SIZE:4.86kW AC SYSTEM SIZE:3.8kW MODULE COUNT:12 MODULES USED:HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY:NAT'L GRID UTILITY ACCT #:6266266019 UTILITY METER #:95000913 DEAL TYPE:SUNNOVA R1 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com