Loading...
31B-030 (6) BP-2023-1746 43 SUMMER ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 31B-030-001 CITY OF NORTHAMPTON Permit: New Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-1746 PERMISSION IS HEREBY GRANTED TO: Project# NEW 2 FAMILY HOUSE 2023 Contractor: License: Est.Cost: 950000 NU-WAY HOMES INC 013693 Const.Class: Exp.Date: 07/20/2025 Use Group: Owner: INC NU-WAY HOMES, Lot Size (sq.ft.) Zoning: URC Applicant: NU-WAY HOMES INC Applicant Address Phone: Insurance: 10 WHITE AVE (413)563-0085 EAST LONGMEADOW, MA 01028 ISSUED ON: 12/20/2023 TO PERFORM THE FOLLOWING WORK: NEW 2 FAMILY HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: fY ' Y .. � bi � I Fees Paid: $2,223.60 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner File #BP-2023-1746 - d i<. APPLICANT/CONTACT PERSON:NU-WAY HOMES INC 10 WHITE AVE EAST LONGMEADOW, MA 01028(413)563-0085 PROPERTY LOCATION 43 SUMMER ST MAP:LOT 31B-030-001 ZONE THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE. ZONING FORM FILLED OUT Building Permit Filled out Fee Paid $2,223.60 Type of Construction: NEW 2 FAMILY HOUSE New Construction Non Structural Renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 3 sets of Plans/Plot Plan Driveway Grade% THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION PRESENTED: )( Approved Additionalpermits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:* Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* • Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay I i I 'ill/ Sigh:ture of Building Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning&Development for more information. The Commonwealth of Massachusetts Board of Building Regulations and Standards FOR MUNICIPALITY /-•-','1Vt: Massachusetts State Building Code,780 CMR USE 't ‘\ Building Permit Application To Construct,Repair,Renovate Or Demolish a Revised Mar 2011 ���r", One-or Two-Family Dwelling 4�c ��• , This Section For Official Use Only O 4`49 L..�� ,,. Building Permit Number: _ea-J•�^ 7 �' Date Ap 'ed: ��O� >� \fi. Building Official(Print Name) I Signature I I � "9,4):). iy �{T SECTION 1:SITE INFORMATION O,Y�2S,A 1. a Address: 1. Asse ors Map&Parcel N mbers �90).Ci.. 1.1a Is this an accepted street?yes x no Map Num r Parcel Number 1. .RitInformation• tj 1. 2rop nsions: ^ / c/ �f�, a ��se /yAl (s o!, (c) Zoning District Proposed Use Lot ea(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided /0 ' /0 ' '4 /0 ao /ID ao as 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Food Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: — Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: - NU—!ala eC��c. 643, r1 p-G/ow-- iv7s 0io.2 Name(Print) City,State,ZIP /0 6)4 e /i(>c. (Y/4) S63 -O6$5-- ,VQwil/- ,./es l : ans.9.'I,44-,, No.and Street Telephone Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.0 Number of Units Other 0 Specify: Brief Description of Proposed Work': '' '/ SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ WI 001 GOO 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee Sv/000 0 Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ �O OOO 2. Other Fees: $ 4.Mechanical (HVAC) $ oOo List: ,5L', 5.Mechanical (Fire $ _�1. ra O Suppression) Total All Fees:Ail •V Check No. 1t Wtheck Amount: ,t O Cash Amount: 6.Total Project Cost: $ 5SQ/Min— 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) --_�C/ /c <' ' -3 cense Number Expirati ate Name of CSL Holder / , /O W 1 i ? ve List CSL Type(see below) o.and Street Description C4O.ST Me`4 '10W.—ill StDYd.2� Unrestricted(Buildings up 35,000 Cu.ft.) Restricted 18E2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering (etire 1 WS Window and Siding 5LTT!/�jJ �+ / SF Solid Fuel Burning Appliances �J 0-1v u w i S(�D Q , I Insulation Telephone Email address ( pt/W 1 D Demolition 5.2 Registered Holly Improve ent Contractor(HIC) /Qa�aZ HIC Registration Number Co on Date HIC Company Name ' u y or HIC Registrant Name N (,s.tC{ 1 16 Airs l �/Y� ( 7 No.and Street `/ Email address// City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes i)igr...._ No 0 SECTION 7a:0 R AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the informati contained in this application is true and accurate to the best of my knowledge and unde 40.•;(_. A/Cr z� /�aa CAA/ ill• Print Owner's or A ' d Agent's Name(Electro • Signature) / / Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c.142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.eov/dvs 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) 3)y t q F Habitable room count /2 Number of fireplaces Number of bedrooms $' Number of bathrooms L Number of half/baths Type of heating system .7" Number of decks/porches I Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD �jg G Gt.t oen SIDE YARD Cj/U`d SIDE YARD FRONT SETBACK FRONTAGE City of Northampton oµYM�Mvio ... ...`..SAC -r Massachusetts �r s:. e (� a 5 DEPARTMENT OF BUILDING INSPECTIONS a: .01) ; 212 Main Street • Municipal Building J�.. ,Ci Northampton, MA 01060 Sp`f . CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40,S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: C � ��GcJ �i„ � � aV/09/( gt"C7 1 The debris will be transported by: Name of Hauler: I}S /4 /7 G- Signature of Applicant: ate: /.• "-- d �aa3 \ The Commonwealth of Massachusetts 1C s_�� Department of Industrial Accidents _"io'tr= s1 1 Congress Street,Suite 100 `:=t.tihs�j Boston,MA 02114-2017 '?;,.N..„ ' N'ww.mass.got/dia 1Swkers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumber.. TO BE FILED Ss ITt!'FEE PERMITTING AUTHORITY. AnDlicanl Information / Please Print Leeibls Name(Business,'Organization Inch%t dual I: NU— Ca.) '4 _1S r 2.C2. Address: /0 4)I'lrrre /91.1i pv1 Fi 0/0.7-? Q City/State/Zip: Fq„ST Lame Phone#: C(//31 sG 3-OO O-- Are yes an employ er?('herb the appropriate boa: Type of jest(required): 1. am a employct with employees(full and part-timel-' ❑I 7. ew construction 2.0I am a sole proprietor or partnership and hose nu employes,working forma is .❑Remodeling any rapacity_[No workers'comp.insurance rcqun it) 9. ❑Demolition 3LI 1 am a homeowner doing all wur►myself.[No wort era'comp.uaaia n e required.]' 4.0 lam a homeowner and will be hiring curler&iura to conduct all work on my property. I will 10 ID Building addition ensure that all comm.-tors tither hate worker.'eu pctlsution nsurance in are sole I I.O Electrical repairs or additions propnctors with no employees. 12.0 Plumbing repairs or additions 50 I am a general contractor and I have hired the sob-contractor.listed un the attached ahem_ 13❑Roof repairs [hose sub-contractors fate employees and has a workers'coop.insurance.; h. ' arc a poration and inofficers have mortised them nght of exemplum per h1GL c. 14, ()the!ef c ror 1.2.$1141.and we have no employees[No workers'comp.insurance required.] shy applicant that cheeks bow al must also fill out the section hell.showing their workers'compensation policy information. Homeowners,who submit this aflldatlt Oldieavne they are doing all work and then hue outside contractors must subnut a new affidasit indimling such. kCunvaetun that check this box must attached an additional sheet show ing the name of the suk-contractor and state%bother or not Moot:crltrties late employees- if the sub-contractors hate employees.ti-y must provide their workers'comp.pukes.number. I am an employer that is providing n'orkers•compensation insurance for m.employees. Below is the Indio.and job site information. Insurance Company Name:_ — Policy#or Self-ms.Lie.#: Expiration Date: Job Site Address: City/State/Zip: Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152.§25A is a criminal violation punishable by a fine up to S1,500.00 an d'or one-year impnsonmcnt,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to S250.00 a dad against the violator.A copy of this statement may be forwarded to the Office of investigations of the DIA for insurance coo crake verif-a'n. i do here y certify it er a.reins and penaltie- r jury that th reformation provided above is true and correct Signature: _� Date. (�A ,�d Phone#: CY/3) 5(O 00 7° ( !Official use only. Do not'.'rite in this area,to be completed by city or town official ('its or-town: Permit/License Or Issuing Authorus Icircle one): I. Board of Health 2.Building Department 3.Cityfrown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6,Oiler ' Contact Person: Phone#: City of Northampton , PI _ ?° .. N.. Sj--i.: SAC r Massachusetts ��? ''•��� Mil �`" ;t, k•,; d� DEPARTMENT OF BUILDING INSPECTIONS � 1y �" - "' 212 Main Street • Municipal Building y�, C'� O""`";`"� Northampton, MA 01060 ft'yh`+ . Fee Calculator for New Residential Construction ONLY 3 iU Location : n �7 li Square Footage Amount I/ Basement @ .20 /8?2-. 378. 7 o 1ST Floor @ .50 9;, -/ q — 2nd Floor @ .50 /7/.�--• 8.S. 1/2 Floors, Finish Attic, Garage @ .20 Deck/ Porches @ .20 - a `7' /3, 10 Total : ),' ' 2)-- '6 DATE(MM/DD/YYYY) �wxv CERTIFICATE OF LIABILITY INSURANCE 12/08/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Anne Brunk NAME: Crimmins-Graveline Insurance (A/O No,Ext): (413)283-8378 �AAic,No): (413)283-2556 1382 Main Street E-MAIL abrunk@cgins.com ADDRESS: P O.Box 905 INSURER(S)AFFORDING COVERAGE NAIC# Palmer MA 01069 INSURER A: United States Liability Ins Co INSURED INSURER B: Nu-Way Homes Inc INSURER C: 10 White Avenue INSURER D: INSURER E: East Longmeadow MA 01028 INSURER F: COVERAGES CERTIFICATE NUMBER: 2023 GL 43 Summer St REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP LTR INSD WVD POLICY NUMBERPOLICY EFF POLICY EXP LIMITS TYPE OF INSURANCE (MM/DD/YYYY) (MM/DD/YYYY) X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1'000,DAMAGE T000 REND CLAIMS-MADE X OCCUR PREMISESO(Ea occu r nce) $ 100,000 MED EXP(Any one person) $ 5,000 A CP2661419A 10/06/2023 10/06/2024 PERSONAL&ADVINJURY $ 1,000,000 GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY PET LOC PRODUCTS-COMP/OP AGG $ eXCI OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY (Per accident) UMBRELLA LIAB _ OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ li yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) 43 Summer Street Northampton,MA 01060 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN City of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. 210 Main Street AUTHORIZED REPRESENTATIVE Northampton MA 01060 ^ �� ( Ffill C i � L ©1988-2015ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD N if /3 Su ( , f17-C4 , °..tn' / >' Home Energy Rating Certificate Rating Date: 2023-11-15 Projected Report Registry ID: Based on Plans Ekotrope ID:vyJjgzo2 HERS® Index Score: Annual Savings Home: 48 Your home's HERS score is a relative 43 Summer St Unit-A performance score.The lower the number, $ 5 7 8 5 Northamton,MA 01060 the more energy efficient the home.To Builder: learn more,visit www.hersindex.com *Relative to an average U.S.home John Handzel -Nu-Way Homes Inc Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu) Annual Cost criteria of the following: Heating 19.5 $1,604 Massachusetts Stretch Code Cooling 0.5 $37 2021 International Energy Conservation Code Hot Water 2.2 $177 Lights/Appliances 22.1 $1,810 Service Charges $120 Generation(e.g.Solar) 0.0 $0 Total: 44.2 $3,748 HERS'Index Home Feature Summary: Rating Completed by: "--," n Home Type: Duplex,single unit Model: John Handzel Custom Duplex-left-A Energy Rater:Paul DellaTorre :so RESNET ID:8776762 Existing Community: Florence NOT`: w Conditioned Floor Area: 2,838 ft2 Rating Company:Energy Compliance Services 1O Number of Bedrooms: 3 27 Hudson Dr.Southwick MA 01077 10 413-427-2423 Reference Primary Heating System: Air Source Heat Pump•Electric•95 HSPF Home 9° Primary Cooling System: Air Source Heat Pump•Electric•16 SEER Rating Provider.Building Efficiency Resources so Primary Water Heating: Residential Water Heater•Electric•3.88 UEF PO Box 1769 Brevard,NC 28712 '0 House Tightness: 3 ACH50(Adjusted Infiltration:2.29 ACH50) 800-399-9620 :•-_ so Ventilation: 120 CFM•54 Watts•ERV \ sow � �1�i��� Duct Leakage to Outside: 17 CFM @ 25Pa(0.6/MOW) This Moro Above Grade Walls: R-23 io Ceiling: Attic R-60 Paul V-/1/z�� . , Zero Energy to Window Type: U-Value:0.28,SHGC:0.28 �(,(,� �(" Hone ° Foundation Walls: R-13 Paul DellaTorre,Certified Energy Rater s,,,,,K, ...Ewa Framed Floor: N/A Digitally signed:11/15/23 at 7:46 AM ekotro a EkotropeRATER-Version:4.0.23281 P The Energy Rating Disclosure for this home is available from the Approved Rating Provider. This report does not constitute any warranty or guarantee. Energy savings cakulated without modifications to the energy model.(As Modeled) 43 Summer St Unit-A Northamton MA HERS*Index Score: Rating Date:Nov 15,2022 48 HERS Registry ID: Annual Estimates: Rating Company: Electric(kWh): 12,957.1 Energy Compliance Services CO2(Tons): 8.3 Rating Provider. Building Efficiency Resources Approx.Energy Cost: $3,748 Rating Provider Address: PO Box 1769 Brevard,NC 28712 HERS'Index Home Feature Summary: Duplex,single unit,3 bedrooms, 2,838 ft' I w Heating:95 HSPF . Cooling:16 SEER ner. NEI a Ventilation: 0 120 CFM•54 W•ERV w et Duct LTO: nos"ear 17 CFM @ 25Pa(0.6/100 ft2) Above Grade Walls:R-23 ° Ceiling:Attic,R-60 Window:U:0.28•SHGC 0.28 Foundation Walls:R-13 Ekotrope RATER-Version: I ekotrope 4.0.23281 Thrs report does not comtitute any warranty or guarantee. IECC 2021 Performance Compliance Property Organization Inspection Status 43 Summer St Unit-A Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple: Community:Florence Builder John Handzel-Nu-Way 0631 John Handzel_43 Summer St Homes Inc Unit-A_Northampton_DP-231115 This report is based on a proposed design and does not confirm field enforcement of design elements. Annual Energy Cost Design IECC 2021 Performance As Designed Heating $853 $771 Cooling $56 $56 Water Heating $87 $87 Mechanical Ventilation $54 $70 SubTotal-Used to determine compliance $1,050 $984 Lights&Appliances w/out Ventilation $882 $882 Onsite generation $0 $0 Total $1,932 $1,867 R405.3 Source Energy Exception:The proposed home uses 4.77 MBtu LESS source energy than the reference home. Requirements ® R405 2 Performance-based compliance passes by 6.2% The proposed house meets the IECC 2021 Performance reference energy bill requirement by S65.13(4 77 MBtu) • R405.2 Item 2 Total UA alternative compliance passes by 14 0% The proposed home meets the UA requirement by 14.0% R405 2 Item 2 Glazed Fenestration SHGC R402 4.1 2 Air Leakage Testing Air sealing is 3.00 ACH at 50 Pa and 0.21 CFM50/ft'Shell Area It must not exceed 5 00 ACH at 50 Pa or 0 28 CFM50 I ft'Shell Area. ® R403 3 1 Duct Insulation All ducts are inside the thermal envelope or outside and insulated to at least R8 0 • R403 3.5 Duct Testing R404 1 Lighting Equipment At least 100 0%of fixtures shall be high-efficacy lamps,currently 100 0%are high- efficacy. Mandatory Checklist Mandatory code requirements that are not 2021 IECC Required Items must be checked as complete checked by Ekotrope must be met ® R403 6 2 Mechanical Ventilation Efficacy • R403 6.1 Mechanical Ventilation Energy Recovery O R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 28 The maximum allowed value is (No Limit] e R402 5 Area-weighted average fenestration U-Factor ® R401 2 5 Option 2 Additional energy efficiency R401 2 5 2 2-95%Threshold Met Design exceeds requirements for IECC 2021 Performance compliance by 6.2%. As a 3rd party extension of the code jurisdiction utilizing these reports I certify that this energy code compliance document has been created in accordance with the requirements o1 Chapter 4 of the adopted International Energy Conservation Code based on HAMPSHIRE County If rating is Projected,I certify that the building design described herein is consistent with the building plans specifications and other calculations submitted with the permit application If rating is Confirmed.I certify that the address referenced above has been Inspectednested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will De verified as such by another party. Name: Paul DellaTorre Signature: /�tu4f%)el(a re to Organization: Energy Compliance Services Digitally signed: 11/15/23 at 7:46 AM Ekotrope RATER-Version 4.0.2.3281 IECC 2021 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report IECC 2021 Building UA Compliance Property Organization Inspection Status 43 Summer St Unit-A Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple: Community:Florence Builder John Handzel-Nu-Way 0631 John Handzel_43 Summer St Homes Inc Unit-A_Northampton_DP-231115 This report is based on a proposed design and does not confirm field enforcement of design elements. Building UA Elements IECC Reference As Designed Ceilings 22.8 16.3 Above-Grade Walls 55.0 68.1 Windows,Doors and Skylights 61.5 56.4 Slab Floor: 22.8 22.8 Framed Floors 0.0 0.0 Foundation Walls 35.0 38.1 Rim Joists 6.5 6.3 Overall UA(Design must be equal or lower): 203.6 208.0 Requirements A R402 1 5 Total UA alternative compliance fails by 2 2% Specified envelope UA is 208 BTU/hF This exceeds the maximum of 204 BTU i hF by 2 2% 402 3.2 Average SHGC 0 28 Max SHGC 0.40 Average SHGC of 0.28 is greater than the maximum of 0 40 R402 4 1 2 Air Leakage Testing Air sealing is 3 00 ACH at 50 Pa and 0 21 CFM50/ft'Shell Area It must not exceed 5.00 ACH at 50 Pa or 0 28 CFM50/ft'Shell Area ® R403 3 1 Duct Insulation All ducts are inside the thermal envelope or outside and insulated to at least R8 0 R404.1 Lighting Equipment At least 100 0%of fixtures shall be high-efficacy lamps,currently 100.0%are high- efficacy Mandatory Checklist Mandatory code requirements that are not 2021 IECC Required Items must be checked as complete checked by Ekotrope must be met ® R403 6.2 Mechanical Ventilation Efficacy OR403,6.1 Mechanical Ventilation Energy Recovery R403 3 6 Duct Leakage Testing ® R403 5 2 Hot water pipe insulation Hot water pipes at least 3/4 in diameter must be insulated to R-3 at minimum is R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0.28 The maximum allowed value is INo Limit] • R402 5 Area-weighted average fenestration U-Factor R402 4 1 3 Prescnptive Air Leakage Air sealing is 3 00 ACH at 50 Pa It must not exceed 3 00 ACH at 50 Pa IRC M1505 4.3 Mechanical Ventilation Rate ® R408 2 Additional efficiency package options ✓R408 2 3-Reduced energy use in service water-heating Design fails to meet the requirement for IECC 2021 Prescriptive compliance by 2.2%. Name: Paul DellaTorre Signature: J- (Deffli.T Lie Organization: Energy Compliance Services Digitally signed: 11/15/23 at 7:46 AM Ekotrope RATER-Version 4.0.2.3281 IECC 2021 Prescriptive compliance results calculated using Ekotrope RATER's energy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report 1111:iii -• . . .. 43 Summer St Unit-A `. ., Northamton, MA 01060 ABuilder: John Handzel -Nu-Way Homes Inc Model: John Handzel Custom Duplex-left-A Community: Florence This report is based on a proposed design and does not confirm field enforcement of design elements. THIS HOME IS CERTIFIED TO MEET THE (.'� 2021 INTERNATIONAL ENERGY CONSERVATION CODE A _:. Building Features Ceiling Attic,R-60 Duct Supply R-8.0, Return R-8.0 1 Above Grade Walls R-23 Duct Leakage to Outside 17 CFM @ 25Pa(0.6/100 ft') Foundation Walls R-13 Total Duct Leakage 87 CFM @ 25Pa(Post-Construction) '_' 1111 Framed Floor N/A Heating Air Source Heat Pump•Electric•9.5 HSPF Slab R-0.0 Perimeter, R-0.0 Under Cooling Air Source Heat Pump•Electric• 16 SEER (::i III Infiltration 3 ACH50 Window U-Value:0.28, SHGC.0.28 Water Heating Residential Water Heater•Electric•3.88 UEF •c• As a 3rd party extension of the code Jurisdiction utilizing these reports.I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on HAMPSHIRE County.If rating is Projected.I certify that the building design descnbed herein is consistent with ' the building plans,specifications,and other calculations submitted with the permit application.If rating is Confirmed.I certify that the address referenced above has been inspected/tested (=:.1, and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party 3 Name: Paul DellaTorre Signature: Y (�Veff�Tazte Organization: Energy Compliance Services Digitally signed: 11/15/23 at 7:46 AM Ekotrope RATER-Version 4.0.2.3281 2021 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool.All results are based on data entered by Ekotrope users Ekotrope disclaims at liability for the information shown on this report (,..:•:::".." IECC 2021 Label 43 Summer St Unit-A Model:John Handzel Custom Duplex-left-A Ekotrope RATER-Version:4.0.2.3281 Ceiling:R-60 Above Grade Walls: R-23 Foundation Walls: R-13 Exposed Floor:N/A Slab:R-0 Infiltration:3 ACH50 Duct Insulation:Supply:R8,Return:R8 Duct Lkg to Outdoors: 17 CFM @ 25Pa(0.6/100 ft2) &Door Specs U-Value:0.28,SHGC:0.28 Door:R-6 Heating:Air Source Heat Pump•Electric•9.5 HSPF•22.8 kBTU/h Cooling:Air Source Heat Pump•Electric• 16 SEER•24 kBTU/h Hot Water:Residential Water Heater•Electric• 3.88 UEF•45 gal. Average Mechanical Ventilation: 120 CFM Signature: Air Leakage Report Property Organization Inspection Status 43 Summer St Unit-A Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple; Community:Florence Builder John Handzel-Nu-Way 0631_John Handzel_43 Summer St Homes Inc Unit-A_Northa mpton_DP-231115 General Information Conditioned Floor Area[ft2] 2,838 Infiltration Volume Iftl 22,920 Number of Bedrooms 3 Air Leakage Measured Infiltration 3 ACH50 ACH50(Calculated) 3.00 ELA[sq.in.](Calculated) 62.87 ELA per 100 s.f.Shell Area(Calculated) 1.142 CFM50(Calculated) 1,146 CFM50/s.f.Shell Area(Calculated) 0.208 HERS Rated Home Adjusted Infiltration 2.29 ACH50 Duct Leakage System 1 Leakage to Outdoors 17 CFM @ 25Pa(0.6/100 ft2) Total Leakage Test Type Post-Construction Total Leakage[CFM @ 25 Pa] 87.0 Total Leakage[CFM25/100 s.f.] 3.1 Total Leakage[CFM25/CFA] 0.031 Mechanical Ventilation Rate[CFM] 120 CFM Hours per day 24.0 Fan Power 54 Watts Recovery Efficiency% 65.0 Runs at least once every 3 hrs? true Average Rate[CFM] 120.0 CFM 2010 ASHRAE 62.2 Req.Cont.Ventilation 58.4 2013 ASHRAE 62.2 Req.Cont.Ventilation 115.1 2016 ASHRAE 62.2 Req.Cont.Ventilation 85.8 Ekotrope RATER-Version 4.0.2.3281 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report Building Specification Summary Property Organization Inspection Status 43 Summer St Unit-A Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple; Community:Florence Builder John Handzel-Nu-Way 0631 John Handzel_43 Summer St Homes Inc Unit-A_Northampton_DP-231115 Building Information Rating Conditioned Area[ft2] 2,838.00 HERS ERI 48 Conditioned Volume[IV] 22,920.00 HERS ERI w/o PV 48 Thermal Boundary Area[ft1) 5,504.00 Number Of Bedrooms 3 Housing Type Duplex,single unit Building Shell Ceiling w/Attic R-60 Blown Attic 2x8 16;U-0.017 Windows(largest) U-Value:0.28,SHGC:0.28 Vaulted Ceiling None Window/Wall Ratio 0.07 Above Grade Walls I R-23 rock wool:U-0.056 Window/Floor Ratio 0.07 Found.Walls I R-13.1 Thermax Insulation;R-13 Infiltration 3 ACH50 Framed Floors None Duct Lkg to Outside 17 CFM @ 25Pa(0.6/100 ft2) Slabs I Uninsulated 1;R-0 Total Duct Leakage 87 CFM @ 25Pa(Post-Construction) Mechanical Systems Heating Air Source Heat Pump•Electric•9.5 HSPF Cooling Air Source Heat Pump•Electric•16 SEER Water Heating Residential Water Heater•Electric•3.88 UEF Programmable Thermostat Yes Ventilation System 120 CFM•54 Watts•ERV Whole House Fan N/A Lights and Appliances Percent Interior LED 100% Clothes Dryer Fuel Electric Percent Exterior LED 100% Clothes Dryer CEF 3.7 Refrigerator(kWh/yr) 596.0 Clothes Washer LER(kWh/yr) 400.0 Dishwasher Efficiency 240 kWh Clothes Washer Capacity 3.0 Ceiling Fan(CFM/Watt) 79.0 Range/Oven Fuel Electric Ekotrope RATER-Version 4.0.2.3281 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report y' SUnviki7e4 ST— ;Tee Home Energy Rating Certificate Rating Date:2023-11-15 Projected Report Registry ID: Based on Plans Ekotrope ID: LbpAm9Nv HERS® Index Score: Annual Savings Home: 48 Your home's HERS score is a relative 43 Summer St Unit-B performance score.The lower the number, $5 788 Northdmton,MA 01060 the more energy efficient the home.To Builder: learn more,visit www.hersindex.com 'Relative to an average U.S.home John Handzel Nu Way Homes Inc Your Home's Estimated Energy Use: This home meets or exceeds the Use[MBtu] Annual Cost criteria of the following: Heating 19.5 $1,601 Massachusetts Stretch Code Cooling 0.5 $37 2021 International Energy Conservation Code Hot Water 2.2 $177 Lights/Appliances 22.1 $1,810 Service Charges $120 Generation(e.g.Solar) 0.0 $0 Total: 44.2 $3,745 HERS'Index Home Feature Summary: Rating Completed by: •w.•'"'" Home Type: Duplex,single unit ,s0 Model: John Handzel Custom Duplex-right-IIEnergy Rater.Paul DellaTorre Community: Florence RESNET ID:8776762 Eris,�ne 149 ty Homes 1O Conditioned Floor Area: 2,838 ft2 RatingCompany:En�EnergyCompliance Services 10 Number of Bedrooms: 3 27 Hudson Dr.Southwick MA 01077 11O 413-427-2423 Reference 10o Primary Heating System: Air Source Heat Pump•Electric•93 HSPF Home 90 Primary Cooling System: Air Source Heat Pump•Electric•16 SEER Rating Provider.Building Efficiency Resources eo Primary Water Heating: Residential Water Heater•Electric•3.88 UEF PO Box 1769 Brevard,NC 28712 'o House Tightness: 3 ACH50(Adjusted Infiltration:2.29 ACH50) 800-399-9620 °0 Ventilation: 120 CFM•54 Watts•ERV 4 1 50 1riI� Duct Leakage to Outside: 17 CFM @ 25Pa(0.6/100 ft2) sa N01"e Above Grade Walls: R-23 :o Ceiling: Attic,R-60 Pau/V_Q// I..u/ Zero Ener '" Window Type: U-Value:0.28,SHGC:0.28 �'�Q, Home G Foundation Walls: R-13 Paul DellaTorre,Certified Energy Rater .211011M1 ,..t•.."r. Framed Floor. N/A Digitally signed:11/15/23 at 7:53 AM I e ko t ro r1 e Ekotrope RATER-Version:4.0.23281 F' The Energy Rating Disclosure for this home is available from the Approved Rating Provider. This report does not constitute any warranty or guarantee. Energy savings calculated without modifications to the energy model.(As Modeled) 43 Summer St Unit-B Northamton MA HERS'Index Score: Rating Date:Nov 15,2023 48 HERS Registry ID: Annual Estimates: Rating Company: Electric(kWh): 12,9475 Energy Compliance Services CO2(Tons): 8.3 Rating Provider. Building Efficiency Resources Approx.Energy Cost: $3,745 Rating Provider Address: PO Box 1769 Brevard,NC 28712 HERS Index Home Feature Summary: �r ,,,, ,, D,838 uplexft',single unit,3 bedrooms, 2 ,,j Heating:95 HSPF Home Cooling:16 SEER �ehe«w Hot Water�pg+���gm 141 o Air Leakage 3 Ventilation: 120CFM•54W•ERV Duct LTOnth Nome17 CFM a 25Pa(0.6/100 ft') Above Grade Walls:R-23 eocuer Ceiling:Attic,R-60 Window:U:0.28•SHGC 0.28 ern long "'" Foundation Walls:R-13 Ekotrope RATER Version: I)ekotrope 4.0.23281 This firmer does not mnhaerte any. enntyory,wmtee. IECC 2021 Performance Compliance Property Organization Inspection Status 43 Summer St Unit-B Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple: Community:Florence Builder John Handzel-Nu-Way 0631_John Handzel_43 Summer St Homes Inc Unit-B_Northampton_DP- This report is based on a proposed design and does not confirm field enforcement of design elements. Annual Energy Cost Design IECC 2021 Performance As Designed Heating S853 $770 Cooling S56 $56 Water Heating S87 $87 Mechanical Ventilation $54 $70 SubTotal-Used to determine compliance $1,050 $983 Lights&Appliances w/out Ventilation $882 $882 Onsite generation $0 $0 Total $1,932 $1,866 R405.3 Source Energy Exception:The proposed home uses 4.86 MBtu LESS source energy than the reference home. Requirements e) R405 2 Performance-based compliance passes by 6.3% The proposed house meets the IECC 2021 Performance reference energy bill requirement by S66.42(4.86 MBtu) ® R405 2 Item 2 Total UA alternative compliance passes by 14 2% The proposed home meets the UA requirement by 14 2% ® R405 2 Item 2 Glazed Fenestration SHGC ® R402.4.1 2 Air Leakage Testing Air sealing is 3.00 ACH at 50 Pa and 0.21 CFM50/ft'Shell Area It must not exceed 5 00 ACH at 50 Pa or 0 28 CFM50 I ft'Shell Area O R403.3.1 Duct Insulation All ducts are inside the thermal envelope or outside and insulated to at least R8 0 O R403 3 5 Duct Testing • R404.1 Lighting Equipment At least 100 0%of fixtures shall be high-efficacy lamps.currently 100 0%are high- efficacy. o Mandatory Checklist Mandatory code requirements that are not 2021 IECC Required Items must be checked as complete checked by Ekotrope must be met • R403 6 2 Mechanical Ventilation Efficacy • R403 6 1 Mechanical Ventilation Energy Recovery O R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 28 The maximum allowed value is (No Limit] ® R402 5 Area-weighted average fenestration U-Factor • R401 2 5 Option 2 Additional energy efficiency R401 2 5 2 2-95%Threshold Met Design exceeds requirements for IECC 2021 Performance compliance by 6.3%. As a 3rd party extension of the code Jurisdiction utilizing these reports I certify fiat this energy code compliance document has been created m accordance win the requirements of Chapter 4 of the adopted International Energy Conservation Code based on HAMPSHIRE County If rating is Projected.I certify tnat the building design descnbed herein is consistent with the building plans.specifications,and other calculations submitted with the permit application If rating is Confirmed,I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will De verified as such by another party. Name: Paul DellaTorre Signature: Pad Delta Toile Organization: Energy Compliance Services Digitally signed: 11/15/23 at 7:53 AM Ekotrope RATER-Version 4.0.2.3281 IECC 2021 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report IECC 2021 Building UA Compliance Property Organization Inspection Status 43 Summer St Unit-B Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple: Community: Florence Builder John Handzel-Nu-Way 0631_John Handzel_43 Summer St Homes Inc Unit-B_Northampton_DP- This report is based on a proposed design and does not confirm field enforcement of design elements. Building UA Elements IECC Reference As Designed Ceilings 22.8 15.9 Above-Grade Walls 55.0 68.1 Windows,Doors and Skylights 61.5 56.4 Slab Floor: 22.8 22.8 Framed Floors 0.0 0.0 Foundation Walls 35.0 38.1 Rim Joists 6.5 6.3 Overall UA(Design must be equal or lower): 203.6 207.6 Requirements a R402 1 5 Total UA alternative compliance fails by 2 0% Specified envelope UA is 208 BTU/hF This exceeds the maximum of 204 BTU/hF by20% ® 402 3.2 Average SHGC 0 28 Max SHGC 0 40 Average SHGC of 0 28 is greater than the maximum of 0 40. • R402 4 1 2 Air Leakage Testing Air sealing is 3 00 ACH at 50 Pa and 0 21 CFM50/ft'Shell Area It must not exceed 5 00 ACH at 50 Pa or 0 28 CFM50/ft Shell Area R403 3 1 Duct Insulation All ducts are inside the thermal envelope or outside and insulated to at least R8 0 ® R404.1 Lighting Equipment At least 100 0%of fixtures shall be high-efficacy lamps,currently 100 0%are high- efficacy Mandatory Checklist Mandatory code requirements that are not 2021 IECC Required Items must be checked as complete checked by Ekotrope must be met ® R403.6.2 Mechanical Ventilation Efficacy ® R403.6.1 Mechanical Ventilation Energy Recovery ® R403 3 6 Duct Leakage Testing ® R403 5 2 Hot water pipe insulation Hot water pipes at least 3/4 in diameter must be insulated to R-3 at minimum • R402 5 Area-weighted average fenestration SHGC Area-weighted average fenestration SHGC is 0 28 The maximum allowed value is [No Limit' • R402 5 Area-weighted average fenestration U-Factor aR402 4 1 3 Prescnptive Air Leakage Air sealing is 3 00 ACH at 50 Pa It must not exceed 3 00 ACH at 50 Pa IRC M1505 4 3 Mechanical Ventilation Rate ® R408 2 Additional efficiency package options ✓R408 2 3-Reduced energy use in service water-heating Design fails to meet the requirement for IECC 2021 Prescriptive compliance by 2%. Name: Paul DellaTorre Signature: Pau(%)effaTezte Organization: Energy Compliance Services Digitally signed: 11/15/23 at 7:53AM Ekotrope RATER-Version 4.0.2.3281 IECC 2021 Prescriptive compliance results calculated using Ekotrope RATER's energy and code compliance algorithm Ekotrope RATER is a RESNET Accredited HERS Rating Tool All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report 43 Summer St Unit-B �` �•'' Northamton, MA 01060 Builder: John Handzel -Nu-Way Homes Inc Model: John Handzel Custom Duplex right B Community: Florence This report is based on a proposed design and does not confirm field enforcement of design elements. THIS HOME IS CERTIFIED TO MEET THE `.'::. 2021 INTERNATIONAL ENERGY CONSERVATION CODE • Building Features ==s( Ceiling Attic,R-60 Duct Supply R-8.0,Return R-8.0 Above Grade Walls R-23 Duct Leakage to Outside 17 CFM @ 25Pa(0.6/100 ft2) Foundation Walls R-13 Total Duct Leakage 87 CFM @ 25Pa(Post-Construction) '_ Framed Floor N/A Heating Air Source Heat Pump•Electric•9.5 HSPF Slab R-0.0 Perimeter, R-0.0 Under Cooling Air Source Heat Pump•Electric• 16 SEER , Infiltration 3 ACH50 Water Heating Residential Water Heater•Electric•3.88 UEF Window U-Value:0.28,SHGC:0.28 As a 3rd party extension of the code jurisdiction utilizing these reports,I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on HAMPSHIRE County.If rating is Projected.I certify that the building design described herein is consistent with ' the building plans,specifications.and other calculations submitted with the permit application.If rating is Confirmed,I certify that the address referenced above has been inspected/tested ( 'rs and that the mandatory provisions Of the IECC have been installed to meet or exceed the intent of the IECC or will be venned as such by another party • Name: Paul DellaTorre Signature: /a.uf 1.)elfaT lie Organization: Energy Compliance Services Digitally signed: 11/15/23 at 7:53 AM Ekotrope RATER-Version 4.0.2.3281 2021 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm •• Ekotrope RATER is a RESNET Accredited HERS Rating Tool.At results are based on data entered by Ekotrope users C) Ekotrope disclaims at liability for the information shown on this report (• 1 • '•1..1.•.♦'•11i•.�•k,••'.. ••..•A•.....;:".t ,:b...••/•'111.1/4", ,• ' ♦ ".r:.1- ,•. S . .•�,�♦•,'• • i1•• '•', IECC 2021 Label 43 Summer St Unit-B Model:John Handzel Custom Duplex-right-B Ekotrope RATER-Version:4.0.2.3281 Ceiling:R-60 Above Grade Walls: R-23 Foundation Walls: R-13 Exposed Floor:N/A Slab: R-0 Infiltration:3 ACH50 Duct Insulation:Supply:R8,Return:R8 Duct Lkg to Outdoors: 17 CFM @ 25Pa(0.6/100 ft2) endow&Door SpeallIMINIMIll U-Value:0.28,SHGC 0.28 Door.R-6 111111111111111WPMAIMINIMMINI Heating:Air Source Heat Pump•Electric•9.5 HSPF•22.8 kBTU/h Cooling:Air Source Heat Pump•Electric•16 SEER•24 kBTU/h Hot Water:Residential Water Heater•Electric• 3.88 UEF•45 gal. Average Mechanical Ventilation: 120 CFM Signature: Air Leakage Report Property Organization Inspection Status 43 Summer St Unit-B Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple; Community:Florence Builder John Handzel-Nu-Way 0631 John Handzel_43 Summer St Homes Inc Unit-B_Northa mpton_DP- General Information Conditioned Floor Area[ft2] 2,838 Infiltration Volume[ft'] 22,920 Number of Bedrooms 3 Air Leakage Measured Infiltration 3 ACH50 ACH50(Calculated) 3.00 ELA[sq.in.](Calculated) 62.87 ELA per 100 s.f.Shell Area(Calculated) 1.142 CFM50(Calculated) 1,146 CFM50/s.f.Shell Area(Calculated) 0.208 HERS Rated Home Adjusted Infiltration 2.29 ACH50 Duct Leakage System 1 Leakage to Outdoors 17 CFM @ 25Pa(0.6/100 ft') Total Leakage Test Type Post-Construction Total Leakage[CFM @ 25 Pa] 87.0 Total Leakage[CFM25/100 s.f.] 3.1 Total Leakage[CFM25/CFA] 0.031 Mechanical Ventilation Rate[CFM] 120 CFM Hours per day 24.0 Fan Power 54 Watts Recovery Efficiency% 65.0 Runs at least once every 3 hrs? true Average Rate[CFM] 120.0 CFM 2010 ASHRAE 62.2 Req.Cont.Ventilation 58.4 2013 ASHRAE 62.2 Req.Cont.Ventilation 115.1 2016 ASHRAE 62.2 Req.Cont.Ventilation 85.8 Ekotrope RATER-Version 4.0.2.3281 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the Information shown on this report Building Specification Summary Property Organization Inspection Status 43 Summer St Unit-B Energy Compliance Servic Results are projected Northamton,MA 01060 Paul DellaTorre Model:John Handzel Custom Duple; Community: Florence Builder John Handzel-Nu-Way 0631 John Handzel_43 Summer St Homes Inc Unit-B_Northampton_DP- Building Information Rating Conditioned Area[ft2] 2,838.00 HERS ERI 48 Conditioned Volume[ft3] 22,920.00 HERS ERI w/o PV 48 Thermal Boundary Area[ft2] 5,504.00 Number Of Bedrooms 3 Housing Type Duplex,single unit Building Shell Ceiling w/Attic I R-60 Blown;U-0.017 Windows(largest) U-Value:0.28,SHGC:0.28 Vaulted Ceiling I None Window/Wall Ratio 10.07 Above Grade Walls R-23 rock wool;U-0.056 Window/Floor Ratio 10.07 Found.Walls I R-13.1 Thermax Insulation:R-13 Infiltration 13 ACH50 Framed Floors I None Duct Lkg to Outside 117 CFM @ 25Pa(0.6/100 ft2) Slabs I Uninsulated 1;R-0 Total Duct Leakage 187 CFM @ 25Pa(Post-Construction) Mechanical Systems Heating Air Source Heat Pump•Electric•9.5 HSPF Cooling Air Source Heat Pump•Electric•16 SEER Water Heating Residential Water Heater•Electric•3.88 UEF Programmable Thermostat Yes Ventilation System 120 CFM•54 Watts•ERV Whole House Fan N/A Lights and Appliances Percent Interior LED 100% Clothes Dryer Fuel Electric Percent Exterior LED 100% Clothes Dryer CEF 3.7 Refrigerator(kWh/yr) 596.0 Clothes Washer LER(kWh/yr) 400.0 Dishwasher Efficiency 240 kWh Clothes Washer Capacity 3.0 Ceiling Fan(CFM/Watt) 79.0 Range/Oven Fuel Electric Ekotrope RATER-Version 4.0.2.3281 All results are based on data entered by Ekotrope users Ekotrope disclaims all liability for the information shown on this report