11-022 (2) BP-2023-1518
42 RUSTLEWOOD RIDGE COMMONWEALTH OF MASSACHUSETTS
Map:Block:Lot:
11-022-001 CITY OF NORTHAMPTON
Permit: Solar Build
PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
BUILDING PERMIT
Permit # BP-2023-1518 PERMISSION IS HEREBY GRANTED TO:
Project# 2023 SOLAR Contractor: License:
PIONEER VALLEY
Est. Cost: 37812 PHOTOVOLTAICS CS106329
Const.Class: Exp.Date: 03/14/2024
WASHINGTON-OTTOMBRE, CAMILLE&
Use Group: Owner: GARRETT WASHINGTON
Lot Size (sq.ft.)
Zoning: WSP Applicant: PIONEER VALLEY PHOTOVOLTAICS
Applicant Address Phone: Insurance:
311 WELLS ST - SUITE B (413)772-8788 375928710105
GREENFIELD, MA 01301
ISSUED ON: 10/26/2023
TO PERFORM THE FOLLOWING WORK:
INSTALL 30 PANE 12.15 KW ROOF MOUNT SOLAR SYSTEM (NO STRUCTURAL NO BATTERY)
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter: Footings:
Rough: Rough:/(- (2 House # Foundation:
Final: Final: //- / j-as Final: Rough Frame:
Gas: Fire Department Driven ay Final: Fireplace/Chimney:
Rough: Oil: Insulation:
Smoke: Final: ( I< II-IN-23 IL,Q
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature:
I ,
Fees Paid: 575.00
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
�2 j2u,57-Z�-�)Oc1 7i7iD&E- /21)
Commonwealth of Massachusetts Official Use Only
Permit No.: Et- Zp2•.a--1.73
=� = Department of Fire Services Occupancy and Fee Checked:7 /t/2tJ2
BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/2023] pv
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
cam' All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
City or Town of: Northampton Date: 10/25/2023
To the Inspector of Wires:By this application,the undersigned gives notices of his or her intention to perform the electrical work described below.
Location(Street&Number): 42 Rustlewood Ridge, Northampton,MA 01062 Unit No.:
Owner or Tenant: Garrett Washington Email: washington_garrett@yahoo.com
Owner's Address: 42 Rustlewood Ridge, Northampton, MA 01062 Phone No.: (440)984-8647
Is this permit in conjunction with a building permit?(Check appropriate box)Yes O No®Permit No.:
Purpose of Building: Res. Utility Authorization No.:
Existing Service: 400 Amps 120 / 240 Volts Overhead❑ Underground❑✓ No.of Meters: 1
New Service: Amps / Volts Overhead❑ Underground❑ No.of Meters:
Description of Proposed Electrical Installation: Wire in a 30 panel roof mounted PV array.System size 12.15kW DC/
10kW AC. b M-v .AA/ a4 no bj .,
Completion of the following table may be waned by the Inspector of Wires. /
No.of Receptable Outlets: No.of Switches: Generator KW Rating: Type:
No.Luminaires: No.of Recessed Luminaires: No.Wind Generators: Wind KW Rating:
No.Appliances: KW: No.Water Heaters: KW: No.Transformers: Total KVA:
Space Heating KW: Heating Equipment KW: No.Motors: Total HP: Total KW:
No.Heat Pumps: Total KW: Total Tons: Fire Alarm System❑ No.of Devices:
Swimming Pool:ln-Grnd.❑ Above-Grnd.❑ Hot-Tub❑ No.of Self-Contained Detection/Alerting Devices:
No.Oil Burners: No.Gas Burners: Video System ❑ No.of Devices:
No.Air Conditioners: Total Ions: Telecom System❑ No.of Outlets:
No.Energy Storage Systems: KWH Storage Rating: Security System ❑ No.of Devices:
Solar PV KW DC Rating:12.15 Solar PV KW AC Rating: 10 No.of Electric Vehicle Supply Equipment:
No.of Modules: 30 Roof-Mount❑✓ Ground-Mount❑ Level 1 ❑ Level 2❑ Level 3❑ Rating:
OTHER:
Solar
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $24,577.80 (When required by municipal policy)
Date Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
FIRM NAME: Pioneer Valley Photovoltaics Coop A-1 ®or C-1 ❑LIC.No.: 3877
Master/Systems Licensee: Pablo Revelo LIC.No.: 22381 A
Journeyman Licensee: LIC.No.:
Security System Business requires a Division of Occupational Licensure"S".IC. S-LIC.No.:
Address: 311 Wells Street,Suite B,Greenfield, Mass.,01301
Email: buildingpermits@pvsquared.coop Telephone No.: 413-772-8788
I certify,under the pains an enalties of perjury,that the information on this application is true and complete.
Licensee: C P �, ' c1, rint Name: Pablo Revell() Cell.No.: 413-834-3232
INS CE CERA E: Unless waived by the owner,no permit for;the performance of electrical work may issue unless the licensee
provides proof of liability including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE❑✓ BOND❑ OTHER❑ Specify: Workers Comp
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law.By my signature below,I hereby waive this requirement.I am the: (Check one)Owner❑ Owner's agent❑
Owner/Agent: Tel.No.:
Signature: Email.:
`-19 rIve/ ce - (f )I
-,a9 1 n(1) is - 1 /