Loading...
42-078 (7) BP-2023-1525 92 GLENDALE RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 42-078-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-1525 PERMISSION IS HEREBY GRANTED TO: Project# 2023 SOLAR Contractor: License: Est.Cost: 62884 PLUGPV LLC 1 1 161 1 Const.Class: Exp.Date: 11/30/2024 Use Group: Owner: STEVEN CLAYBAUGH, JOSEPH &JOHN Lot Size (sq.ft.) Zoning: WSP Applicant: PLUGPV LLC Applicant Address Phone: insurance: 630 7TH AVE (518)948-5316 WC 4241376-00 TROY, NY 12182 ISSUED ON: 10/30/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 35 PANEL 14.175 KW ROOF MOUNT SOLAR SYSTEM (NO STRUTURAL NO BATTERY) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: ♦' 9 TO • 1 Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner ........,z�.�........,....................ter.-...�....�....-... . �..��.......�.-.�..... The Commonwealth of Massachus tts ' . Board of Building Regulations and anda i s I FOR Massachusetts State Building Code 780 • RC v, J UN1C1 ALITY USE f)� l? Avise' ar 2011 Building Permit Application To Construct,Repair, e vvt ; Or Demo a i One-or Two-Family Dwelling 9'tig(4 o This Section For Official Use Only l04, /A,S.p Building Permit Number: b P• -/5.?5 Date Applied: �4°1 %,kt Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 92 Glendale Rd Florence MA 01062 1.1a Is this an accepted street?yes no Parcel ID 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 8 Private 0 Zone: j] Outside Flood Zone? Municipal B On site disposal system 0 Check ifyesil SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Joseph Claybaugh Florence MA 01062 Name(Print) City,State,ZIP 92 Glendale Rd 323-828-0992 globetrekkerjoe@yahoo.com No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other El Specify:Solar panels Brief Description of Proposed Work2: safe and code compliant installation of 35 rooftop solar photo voltaic modules 14.175kW SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) I.Building $ 57,884.16 1. Building Permit Fee: $ Indicate how fee is determined: 0 Standard City/Town Application Fee 2. Electrical $ 5000.00 0 Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Total All Fees: Suppression) I,�� 62 884.16 Check No. heck Amount: -I Cash Amount: 6.Total Project Cost: $ 0 Paid in Full 0 Outstanding Balance Due: Treasurer's Approval: Board of Health DPW Conservation Comm Approval: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-111611 11/30/2027 Sheldon Keck License Number Expiration Date Name of CSL Holder List CSL Type(see below) u 57 Wachusett St No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft.) Franklin MA 02038 R Restricted I&2 Family Dwelling City/Town,State,ZIP M Masonry S/_ - f) RC Roofing Covering l L�'W WS Window and Siding Signature SF Solid Fuel Burning Appliances 518-391-8636 permits@plugpv.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 205087 4/18/2024 PlugPV LLC HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 630 7th Ave '/LlL�Z� N96.dt- projects@plugpv.com No.and Street Signature Email Troy NY 12182 518-948-5316 City/Town, State,ZIP Telephone SECTION 6: WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ® No ❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. DottcuppSiignedd by Joseph Claybaugh .i,SEc�s8F3o�<Alc - 10/19/23 5 Print Owner's Name atguuiuic Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Chanelle Williams ChajreUe 10/19/23 Print Owner's or Authorized Agent's Name Signature Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" I IIC 1.vnefni/fl rlCUIIlI of /r1UJ.lU4RUJC!/J Department of Industrial Accidents • Office of Investigations -F' Lafayette City Center == 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/lndividual):PlugPV, LLC Address:630 7th Ave City/State/Zip:Troy, NY 12182 Phone #:518-948-5316 Are you an employer? Check the appropriate box: Type of project(required): 1.❑� I am a employer with 20 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition workingfor me in anycapacity. employees and have workers' P tY 9. [' Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 1 I.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no q ] employees. [No workers' 13.❑■ Other Solar comp. insurance required.] *Any applicant that checks box#1 must also till out the section below showing their workers'compensation policy information. Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for m1'employees. Below is the policy and job site information. Insurance Company Name: Liberty Mutual Fire Ins Co Policy#or Self-ins. Lic. #:WC233SB21 Q79012 Expiration Date:2/14/2024 Job Site Address: 92 Glendale Rd City/State/Zip: Florence MA 01062 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury'that the information provided above is true and correct. Signature: 5W4 44642, Date: 10/18/23 Phone#: 518-948-5316 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): 10Board of Health 20 Building Department 3.DCity/Town Clerk 4.0 Electrical Inspector 5E1Plumbing Inspector 60Other Contact Person: Phone#: ACo CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD YYVY) 10/03/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Linda Abodeely NAME: Hughes Insurance Agency,Inc. (A IC, Eat): (518)793-3131 IA c.No) (518)793-3121 328 Bay Road E-MAIL Linda@HughesInsurance.com ADDRESS: PO BOX 4630 INSURER(S)AFFORDING COVERAGE NAIC# Queensbury NY 12804 INSURER A: Southwest Marine&General Insurance Company 12294 INSURED INSURER B: Travelers Casualty Ins Co of America 19046 PLUGPV LLC INSURER C: 630 7th Avenue INSURER D: INSURER E: Troy NY 12182 INSURER F: COVERAGES CERTIFICATE NUMBER: 23-24 MA Master 1 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RETED CLAIMS-MADE [X OCCUR PREMISES(Ea occurrence) $ 100,000 MED EXP(Any one person) $ 5,000 A PK202300016943 03/15/2023 03/15/2024 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY X PRO LOC PRODUCTS-COMP/OPAGG $ 2.000,000 ECT OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) X ANY AUTO BODILY INJURY(Per person) $ B - OWNED SCHEDULED BA-3S444689-22-42 05/17/2023 05/17/2024 BODILY INJURY(Per accident) $ - AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE $ _ AUTOS ONLY _ AUTOS ONLY (Per accident) X UMBRELLA LIAR X OCCUR EACH OCCURRENCE $ 1,000,000 A - EXCESS LIAR CLAIMS-MADE EX202300001804 03/15/2023 03/15/2024 AGGREGATE $ 1,000,000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Subject to all policy terms,limitations and conditions: Certificate Holder is Additional Insured when required by written contract,agreement or permit. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN City of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. 212 Main St, AUTHORIZED REPRESENTATIVE Northampton MA 01060 �),�/�• GP.cu I / � ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD ACOREI CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) 10/05/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lily Martin United States Insurance Services (A/C.(HN.E>tt): 866-405-5498 FAX No): 1190 Winterson Road,Suite 100 E-MAIL : osc@nysif.com ADDRESS INSURER(S)AFFORDING COVERAGE _ NAIC# Llnthicum MD 21090 INSURER A: Zurich American Insurance Company INSURED INSURER B: PLUGPV LLC INSURER C: 630 7TH AVE INSURER D: INSURER E: _ TROY NY 12182 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP W M/ LIMITS LTR INSD VD POLICY NUMBER (MM/DD/YYYY),(MDD/YYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCEDAMAGE TO $ CLAIMS-MADE OCCUR PREMISES(EaENTED occurrence) $ MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY (Per accident) UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTIONS $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY STATUTE ER Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE EACH ACCIDENT $ 1,000,000 A E.L.OFFICER/MEMBER EXCLUDED? n N/A WC 4241376-00 04/21/2023 04/01/2024 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN City of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. 212 Main St AUTHORIZED REPRESENTATIVE Northampton MA 01060 ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD Pzs structural ENGINEERS October 16, 2023 PIugPV LLC 630 7th Avenue Troy, NY 12182 Subject: Structural Certification Letter Job Number: PZSE Portal# P23-116101702X Project Name: Claybaugh,Joseph Client PO: SD6250 Address: 92 Glendale Rd, Northampton, MA 01062 Attn.:To Whom It May Concern Re: Residential Flush-Mount Solar Photovoltaic Installation PZSE's scope of work is limited to performing a structural evaluation of loading at the address above. After review, PZSE certifies that the alteration to the existing structure by installation of the PV system meets the requirements of the applicable codes and criteria shows below: Design Criteria • Applicable Codes: 780 CMR,ASCE 7-10 and NDS-15 • Ground Snow Load: 40 lb/sqft • Basic Wind Speed: 117 mph, Exposure Category B • Existing Roof Dead Load: 7 lb/sqft • Existing Roof Live Load: 20.00 lb/sqft The existing structure is adequate to support the PV alteration per Code Sections 402.3 and 402.4 Residential PV Module Assembly The PV module assembly including structural supporting components shall be installed in accordance with the manufacturers specifications and meets or exceeds all requirements set forth by the referenced codes above. Residential Installation Requirements The PV system shall be mounted flush to the existing roof surface. The contractor shall notify PZSE of any signs of damage to the roof framing prior to commencing the installation. PZSE shall then determine if the existing roof is adequate to support the applied loads. The electrical engineering and waterproofing system shall be addressed by others. If you have any questions on the above, do not hesitate to call. ,Iv\OF A4,1, i cS Prepared By: •1 ZACHERPAULK. PZSE, Inc. -Structural Engineers Roseville, CA STRUCTURAL o,FSS/ONALelG 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 1 916.961.3960 F 916.961.3965 W www.pzse.com Experience I Integrity I Empowerment THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: LLC Registration. 205087 PLUGPV, LLC Expiration 04118/2024 875 BROADWAY ALBANY, NY 12207 • Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:i.LC Office of Consumer Affairs and Business Regulation gegistraaLan Expiration 1000 Washington Street -$uite 710 205087 04/18/2024 Boston,MA 02118 PLUGPV.LLC SHANE NOLAN 375 BROADWrA „r^0( ��+.ALBANY NV 12207Undersecretary alld without signature 10/23/21 11:30AM CSL-Sheldon Keck 2024.jpg Commonwealth of Massachusetts Division of Occupational Licensure Board of Building Regulations and Standards Constry n (S errvisor CS- 111611 ► spires: 1113012024 4i SHELDON K§CK :f 57 WACHUSETT ST. 1 r 3 UNIT 1 FRANKLIN MA'..02038 . �•. ' ;! et . ) 11 Commissioner cji 0, f . (Aluita, if https://drive.google.com/drive/folders/18UbJEbe2FoUnOGh8zKXtLCXh5wCxjQgb 1/1 Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card Registration: 205087 PLUGPV, LLC Expiration: 04/18/2024 875 BROADWAY ALBANY, NY 12207 Update Address and Return Card. Office of Consumer Affairs &Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE: Supplement Card before the expiration date. If found return to: Registration Expiration Office of Consumer Affairs and Business Regulation 205087 04/18/2024 1000 Washington Street -Suite 710 PLUGPV, LLC Boston, MA 02118 SHELDON KECK 875 BROADWAY ��s"j°' � l ALBANY, NY 12207 Undersecretary Not valid without signature PHOTOVOLTAIC SYSTEM >- 1: •SYSTEM SIZE: g / /A NAMEPLATE: 14.175 KW DC 110 KW AC 3 0am.A VaRN• ' V� EQUIPMENT: pJ (35)REC SOLAR REC405AA PURE BLACK SERIES I !.L PV MODULES: ••••••Ir (405W) SOLAR MODULES ..1' PV OPTIMIZER(S): (35)S440 SOLAREDGE POWER OPTIMIZER CL # 92 Glendale Rd, INVERTER(S): (1)SOLAREDGE SE10000H-US INVERTER A NorMImllon MA I'O- l �`°'"^n, 01062.United SAWN AC a • COMPONENT(S): (1)60A FUSED AC DISCONNECT _p • • W TYPE OF INTERCONNECTION: LOAD SIDE TAP INTO MMD ., O,-Y i? • SCOPE OF WORK: ;'�>v. ,, - d 5 g. INSTALLATION OF A CODE COMPLIANT,UTILITY INTERACTIVE / _-I PHOTOVOLTAIC ELECTRIC SYSTEM. - 0 0• AERIAL VIEW 42.295358,-72.716207 VICINITY MAP fig 2020 NATIONAL ELECTRIC CODE • 2015 PORTION OF THE INTERNATIONAL FIRE CODE JOSEPH CLAYBAUGH: 92 GLENDALE RD, NORTHAMPTON, MA 01062, USA J\ 2015 INTERNATIONAL RESIDENTIAL CODE •N� in ` 2015 INTERNATIONAL BUILDING CODE �- o GENERAL NOTES: ELECTRICAL NOTES: Y w- APPLICABLE CODE PER LOCAL AUTHORITY HAVING 1. DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF 1. ALL EQUIPMENT IS LISTED FOR USE. `` + RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE 2 MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. JURISDICTION NOTED OR STANDARDIZED. 3. ANY EQUIPMENT OR ELECTRICAL MATERIALS USED FOR THIS INSTALLATION S ��,••• V 8 � 2. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. SHALL BE NEW AND LISTED BY A RECOGNIZED ELECTRICAL TESTING W < ! 3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT.WIRE.EQUIPMENT LABORATORY. Qi DEVICES.OVER-CURRENT PROTECTION.GROUNDING SYSTEMS.ETC.(ALL 4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY EQUIPMENT AND MATERIALS)THE CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION 0 V ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE NETWORK VOLTAGE HAS BEEN RESTORED. LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. S. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. 4. ALL OUTDOOR EQUIPMENT SHALL BE MIN.NEMA 3R RATED. 6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT - - V I . APPLICABLECODES 5. METAL CONDUIT AND ENCLOSURES SHALL BE USES IIMERE PU SOURCE OR CALCULATED AT THAT COMPONENT.OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SHALL ` p N 6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS AND AT LEAST 8. BE PROPERLY GROUNDED. 0 ( ABOVE FLUSH VENTS. I. DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM. '0 V. COVER PAGE 7, THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL B MARKINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE Q Z REQUIREMENTS GIVEN BY UTILITY COMPANIES. DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. 8. FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEETS. 10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL PV2 SITE PLAN 9, ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO BOXES OR JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE %. 60 /' REQUIREMENTS BY NEC AND THE LOCAL MU.THE AHJ MAY HAVE SPECIAL JURISDICTIONAL REQUIREMENTS. • / 1 LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT.THIS MAY 11. FOR ANY UNGROUNDED PV SYSTEM.A LABEL READING:WARNING- DATE PV3 MOUNTING PLAN ENCOMPASS LANGUAGE INCLUDING,BUT NOT LIMITED TO.THAT FOUND IN NEC ELECTRICAL SHOCK HAZARD.THE DC CONDUCTORS OF THIS PHOTOVOLTAIC - ARTICLES 690.5(C),690.14(CXZ).690.17.690.53.690.35(F).690.54.890.64(BX7)+RO SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED.'SHALL BE PLACED AT 10/14/2023 705.10. EACH JUNCTION BOX,COMBINER BOX.DISCONNECT AND DEVICE WHERE PV4 STRUCTURAL DETAILS 10. ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC ENERGIZED,UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE. REFERENCES. 12. INVERTER(S)SHALL CONTAIN AGROUND FAULT DETECTION AND INTERRUPTION / DESIGNED BY'. 1 DEVICE. • PVS-5.1 MOUNTING DETAILS 13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND OMV STRUCTURAL NOTES: ELECTRICALLY CONTINUOUS. jl{OF,L[q�C� 14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CECNEC. LPL V' 1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY CHANGE,BUT SHALL 15. BACKFED SOLAR BREAKER(S)SHALL BE INSTALLED AT THE OPPOSITE END OF "9�1� PV6-6.1 ELECTRICAL DIAGRAMS THE CIRCUIT OR FURTHEST AWAY FROM THEMNN BREAKER PAUL K. 'ryGBE ACCURATELY SPACED. 16. ALL`IRE.VOLTAGES.AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO 2. MOUNTS SHALL BE STAGGERED WHEN NECESSARY TO EVENLY DISTRIBUTE e.1 ZACHER % PV7 MARKING S LABELS TEMPERATURE DEBATING AND LOCATION. I -1 3. DO NOT SPNICETRNLSEN MIDDLE 50'h OF SPAN BEM'EEN TWO MOUNTS. 1T. ONLY COPPER(GU)DCONDUCTORS SHALL BE USED.CONDUCTORS SHALL BF STRUCTURAL y STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. 555n ' 'ATTACHMENTS I DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. \ Q 1N 9. ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS. ` _ 20.ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF SSIONAL MANUFACTURERS SPECIFICATIONS RAIL INDEX GENERAL NOTES PV1 2 / ` ARRAY 1 X ARRAY 2 1 0 Ix TILT:39° T1LT:18' Q. y AZIMUTH:265' AZIMUTH:85' lJ,n J ff DRIVE WAY y 45'_e• 4 a 1 O a____ 1 ril \ 0 Z m a ARRAY SPECIFICATIONS Q ,-0) TM I"I I METER MAIN COMBO d z 01- Z C7 AC DISCONNECT FUSED UJ = 0 o Q INVERTER 0_ < �� r COMBINER PANEL w 0 • 1 1 MAIN SERVICE PANEL 0 Z rn t'v: _ ] 18°VENTILATION SETBACK 0 c� -,� j�/ 3At ' 'WIDE FIRE ACCESS PATHWAY it Q' M3'x3'GROUND LADDER ACCESS POINT n �� r LEGEND , Lu Lu W I— r Y CA Y p O 1111111111 NOTES _ N U Q 2 1. LOCATION OF JUNCTION BOX(ES), AC p J DISCONNECTS(S).AC COMBINER PANEL(S),AND / OTHER ELECTRICAL EQUIPMENT(S) RELEVANT / > 95'-11" _ TO PV INSTALLATION SUBJECT TO CHANGE 0 U w < BASED ON SITE CONDITIONS. U w 0 - 2.SETBACKS AT RIDGES CAN BE REDUCED TO g d Q m 18 INCHES IN COMPLIANCE WITH IBC 1204a. .2.1.2.: 0 = N ! TOTAL PLAN VIEW AREA=1827.36 SQFT 1 Z -, TOTAL PV AREA=35(74 IN)(41.1 IN)/(144 IN^2) 0 a M 1 =739.2 SQFT �V w / 1 (739.2 SOFT/1827.36 SQFT)100=40.45% '' DATE TOTAL PV AREA POPULATES 40.45%OF TOTAL 10/14/2023 PLAN VIEW AREA AND IS NOT WITHIN THE 33% VVIMMI�I'`� REQUIREMENT. c DESIGNED BY S OMV POOL kFS jH OF ASS y /0.i PAUL . c., ZACHERK `fn _ (STRUCTURAL y PROPERTY LINE \ a SQJs .�i PV2 9s,DNAL 3' WIDE FIRE ACCESS PATHWAY 21_3' a ,I. r~ 13'-5" - 27'-4" (9 1 i I T 1 , ff If J^ 1 . I • ._—i .-F---.--1-• • • / 1 -F-1---0- -fir- -•- -.-- ---•---4---• -d-•-•i = p �i • I �Ii i 1 F- . —LI-- . • 1 z M I- _ m i s ern 0 _ Z� Z 0 0 o I II Q w D 0 N 0 MP1 2 O0 w TILT: 39° 0 AZIMUTH:265° a J r"- 38'-2" 1 jl . • I- w • I tlliI1 .: + • • • • CO y Y Y p C3 Q / , • . _ _Ilr 1 I a J. + 0 v uQi II .l ! Ti i!IIIt -•'i of WD ' • • • •. t. • • '---III —� • 1- a x N 0.0\4 OF Z j MP2 Oi PAUL K. C�Y� 0 a- o Z TILT: 16° ZACHER (n �V J. SOLAR MODULE `PZSE advises that best AZIMUTH:85° STRUCTURAL practice in snow load areas is ,.1 / DATE to install staggered \/�'4-g`��7o 10/14/2023 TYPE DESCRIPTION QUANTITY attachments" °� yt•► \ / SS/ONAL / DESIGNED AB`Y:, MODULE REC SOLAR REC405AA PURE BLACK SERIES(405W), 35 ROOF SPECIFICATION O'V,V i SOLAR MODULE DC OPTIMIZER S440 SOLAREDGE POWER OPTIMIZER 35 ROOF MATERIAL ASPHALT SHINGLE • Applicable Codes: 780 CMR,ASCE 7-10 and NDS-15 k . • Ground Snow Load: 40 lb/sgft INVERTER SOLAREDGE SE10000H-US INVERTER 1 RAFTERS 2•X 10"@ 16"O.C. • Basic Wind Speed: 117 mph,Exposure Category B DISCONNECT 60A FUSED AC DISCONNECT 1 ROOF CONDITION GOOD PV3 J r C IRONRIDGE XR10 IRONRIDGE L FOOT J a Q IRONRIDGE FLASH FOOT 0 < zz N WOOD SHEATHING—� SHINGLE FLASHING CD z 0 ci o 2 0 \- 5/16"x4"STAINLESS z w RAFTERS STEEL LAG SCREW 0 0O z 0 \ N / M eri W ; o LLJ IRONRIDGE XR10 0 Y 0 IRONRIDGE L FOOT 0 0 w g J ~ SOLAR MODULE c� N z - r Y WOOD SHEATHING O o z U CD ' � \�IRONRIDGE FLASH FOOT i � 4 SHINGLE FLASHING_— :_____--------------- - DATE 10/14/2023 ''' l DESIGNED BY: -5/16"x4"STAINLESS s � pa-jNoF'�q,,6 \ OMV J RAFTERS STEEL LAG SCREW AI PAUL K.ZACHER STRUCTURAL ti FSS/ p Eta'. STRUCTURAL ATTACHMENT DETAILS PV4 / 1 , > g d (7 w t Project Details a Name eep',C eMtat D Date 10/160023 Bill of Malmo,. U .b Location 92 Glenda.Road.NerManloton.MA01062 Total nl0dole. 35 Pert SP.= Total(By Moms. W REC So -.REC405AA Pore(30mm) Total welts 14.175 Rails6 Splices / Z Dimensions ()mereims:T1.69-x40.0-x1.1W(18210mmx10160mmx30.Omm) Attachments TI AR-10-1688 0 a 0 ASCE 2.10 Rails per row 2 xo1.0.R.r taa heo I F ARID MRBaeeaD sSena1 0 12 —I Q Clomps t ptae1M19 OH Gep lip Le Z a J Q Attachments = LU <2 QMLM-Vi•Ol 0 11 nnve C0 O Z .Mae G , J BMW-S 2-A1 0 11 C) Soave-.Soesv mamas N 03 Auessories QM-RUG-01M1 \ D 4—.— -.--. ...... . BVG Coma want ma // t`\\System Vhpht Load Assunptens W O LV Total'swam weight 1.709 0 es Wnd exposure B I- j Weightlanachlnent 252Ms Wtnaspeed 117mM >Iw Y Y 0 R.Cam3 wwOht 207918. Ground snort bed ppl vI /. < c0 Dap M lriawl septa 25ps1 AOacbl9 .p.c MW ap po 4.0' \ 0 Roof Information /jy Sea O /\ ' Roof Material Sanely Como 5tiuple Root maternal Comp Sham. 0 U Cr Budding hepnt 10 ti Roof.lamea che L-M0a. p(L Bo.) V J w D Stoppered attachments yes g a Q,_ N Roofabpe 19 Ranee hardware e () tb 7 = CN Risk cNeyoryZ J F- SpecifiC gravity 0.5 0 d a Z `V DD Span Details AR10 Peruse DATE Zoo. Max span Max Cantilever 1 s'3 O r 10/14/2023 5 3 21- / DESIGNED By. 5- 77 �,-"0`4,�59 OMIV (14 , PAUL K. ZACHER ----- -- STRUCTURAL 44, 5p PV5 w �� D % (E)200A g 200A METER MAIN - MAIN SERVICE COMBO a t PANEL 120/240V 3 SOLAREDGE 60 AC 120/240V \ 1 STRING OF SE10000H-US DISCONNECT 0 z 11 MODULES INVERTER FUSED (E)200A (r)• = a W/OPTIMIZERS "1 °C "�R° °E° 4 Q _ _ 60A/2P • • ¢Q m 1 a 1 STRING OF �Q �i% • • o } O 12 MODULES n� U o_o LOAD SIDE TAP J tO W/OPTIMIZERS41 • • u 2 „ wQ • E w o� 1 STRING OF �- O © ; U Lu z 12 MODULES O W O d W/OPTIMIZERS © © © © rn , /-- GEC ( U) . � M W o W I- w V O tx > \ O J ce a I-0 J LU g z a0 I- j = N CONDUCTORS AND CONDUIT ` MODULES ` INVERTER(S) J ; OTHER EQUIPMENT J 0 a zl (35)REC SOLAR REC405AA PURE SOLAREDGE SE10000H-US DATE O (6)#10 PV WIRE 60A FUSED AC DISCONNECT (1)#6 THHN GND BLACK SERIES(405W)SOLAR MODULE MAX AC OUTPUT:42 A 10/14/2023 3/4"EMT \ J \ J WATTS STC:405W INVERTER OCPD CALC:(42)X 1.25=52.5A STRUCTURAL ONLY P DESIGNED BY O (1)#6THHN OMV#6 THHN GND ISC:10.14A MIN OCPD:60A �PytHOFMq�� ` OMV J 3/4"EMT IMP:9.56A WIRE AMPACITY:65A @75°C TERMINAL ) PAUL K. 3 #6 THHN VOC:48.9V TEMPERATURE CORRECTION FACTOR: /,STRUCTURAL k O ( ) 31°-35°C=0.94 �� v© (1)#6 THHN GNDVMP:42.4V CORRECTED WIRE AMPACITY:61.10A ` a?Al , 1"EMT off " 'Y 'ss/ONAL PV6 \ l \ l \ } /o- i (E)200A V 200A METER MAIN MAIN SERVICE COMBO a PANEL 120/240V 120/240V / \ SOLAREDGE 60A AC LOAD SIDE TAP / z 1 STRING OF SE10000H-US DISCONNECT - 011 MODULES INVERTER FUSED 2 I d W/OPTIMIZERS_1�T TT OCN "DEG 6oa2P I (E)200A^ LF -r- _ _ 0✓�a •: j (E)200A� C9 m H w • 1 STRING OF �J •^ . ' J o z N 12 MODULES I PI P1 - P ail . ' Q U i • W/OPTIMIZERS — — J =-I--� I � • � W Q� 1 STRING OF �_ L O 4 C• ~) zz 12 MODULES . • • J W/OPTIMIZERS — — �a 4 © kN W ..- GEC \ W ,• c, W I- J p • U N O /Q 2/ O o c[ < ✓ J ui D j ~ CONDUCTORS AND CONDUIT ` MODULES ` IN VERTER(S) ` OTHER EQUIPMENT Z p a o > • J \_ 2 l / V o z` ` O (35)REC SOLAR REC405AA PURE SOLAREDGE SE10000H-US (6)#10 PV WIRE 60A FUSED AC DISCONNECT i• �� (1)#6 THHN GND BLACK SERIES(405W)SOLAR MODULE MAX AC OUTPUT:42 A 3/4"EMT �__ ____I 10/14/2023 WATTS STC:405W INVERTER OCPD CALC:(42)X 1.25=52.5A STRUCTURAL ONLY c DESIGNED By C). (1)#6THHN (1)#6 THHN GND ISC:10.14A MIN OCPD:60A 3/4"EMT IMP:9.56A WIRE AMPACITY:65A @75°C TERMINAL eP`jHOF s64 • OMV TEMPERATURE CORRECTION FACTOR: I PAUL K. O (3)#6 THHN VOC:48.9V 31°-35°C=0.94 / ZACHER (1)#6 THHN GND VMP:42.4V CORRECTED WIRE AMPACITY:61.10A \STRUCTURAL y 1-EMT \ ,81. 50i� , k 0 0 ',,SS CMG , ..., ... J .. PV6.1 r INVERTER AC DISCONNECT MAIN SERVICE PANEL > NEC 705.12(D)(4)),690.56(B) /n w NEC 690.17(4)GROUNDED SYSTEMS NEC 690.14(C)(2) — W m PHOTOVOLTAIC DISCONNECT WARNING J WARNING POWER IS BEING SUPPLIED TO THIS 0_ELECTRIC SHOCK HAZARD. FOR UTILITY OPERATIONS PANEL FROM THE UTILITY AND A o DO NOT TOUCH TERMINALS. NEC 690.54 SOLAR PV SYSTEM. TERMINALS ON BOTH LINE AND NEC 705.12(D)(7) i. z LOAD SIDES MAY BE ENERGIZED IN RATED AC OUTPUT CURRENT: 42 Al Io THE OPEN POSITION. NOMINAL AC VOLTAGE: 240 V WARNING 0OL lil-- �_ INVERTER OUTPUT CONNECTION m m ?< NEC 690.14(C)(2) NEC 690.56 DO NOT RELOCATE THIS g } o OVERCURRENT DEVICE 06 g Z EMERGENCY RESPONDER 0cc PHOTOVOLTAIC DC DISCONNECT THIS SOLAR PV SYSTEM LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED Y d J a BREAKER.IF INSTALLED ANYWHERE ELSE ON DEADFRONT no W EQUIPPED THEN A PERMANENT ARROW FROM LABEL POINTING TO 4 O w WITH RAPID SHUTDOWN PVBACKFEEDBREAKERREQUIRED. M —, C7 TURN RAPID SHUTDOWN m PHOTOVOLTAIC SWITCH TO THE lk NEC690.54 OFF'POSITION ONLY CONDUCTORS INSIDE \ r- l0 SYSTEM EQUIPPED WITH BUILDING OR OFF THE RATED AC OUTPUT CURRENT: 42 A iO ROOF WILL SHUT DOWN 0 RAPID SHUTDOWN ■ NOMINAL AC VOLTAGE: 240 V w — 3Lu NEC 690.14(C)(2) CI) U U O CONDUIT, RACEWAYS, ,�� NEC sso.s3 #INVERTER 1 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC ARRAY O o w a DC ENCLOSURES CABLE OPERATING CURRENT:T27 A g Q g OPERATING VOLTAGE: 400 ASSEMBLIES Z J n MAX. SYSTEM VOLTAGE: 480.0 V 0 o_ . SHORT-CIRCUIT CURRENT: 45.0 A & JUNCTION BOXES 2i DATE NEC 690.31(E)(3)CONDUIT 10/14/2023_ Warning: Photovoltaic Power Source STRUCTURAL ONLY DESIGNED BY s OMV NEC 690.35(F)UNGROUNDED SYSTEMS JUNCTION BOX ACH 94�P`(H OFMq� /1 ZER �� WARNING I STRUCTURAL ti ELECTRIC SHOCK HAZARD. F„so,10 . THE DC CONDUCTORS OF THIS �`PHOTOVOLTAIC SYSTEM ARE SSIONAL� UNGROUNDED AND MAY BE ENERGIZED. PV7 I 1 PHOTOVOLTAIC SYSTEM SYSTEM SIZE: i ///'''\�� a NAMEPLATE: 14.175 KW DC 110 KW AC 7 't EQUIPMENT: J "" J - • PV MODULES' (35)REC SOLAR REC405AA PURE BLACK SERIES - • Cl. (405W) SOLAR MODULES 0 880 4- _J PV OPTIMIZER(S): (35)S440 SOLAREDGE POWER OPTIMIZER o 4 * 92Gle0dale INVERTER(S). (1)SOLAREDGE SE10000H-US INVERTER A •�li• Northampton,MA ZN n AC 33 0I062,U deE SHIeF O n = ~ COMPONENT(S): (1)60A FUSED AC DISCONNECT - a_- W m v, TYPE OF INTERCONNECTION: LOAD SIDE TAP INTO MMD 0 >- p D Q SCOPE OF WORK: CL U ,D INSTALLATION OF A CODE COMPLIANT,UTILITY INTERACTIVE E W = w `PHOTOVOLTAIC ELECTRIC SYSTEM. l O W --I< U (n C1 2020 NATIONAL ELECTRIC CODE AERIAL VIEW 42.295358,-72.716207 VICINITY MAP ° N 2015 PORTION OF THE INTERNATIONAL FIRE CODE JOSEPH CLAYBAUGH: 92 GLENDALE RD, NORTHAMPTON, MA 01062, USA �/ . �\ 2015 INTERNATIONAL RESIDENTIAL CODE / Le. \ .- o 17 efi 2015 INTERNATIONAL BUILDING CODE W GENERAL NOTES: ELECTRICAL NOTES: W APPLICABLE CODE PER LOCAL AUTHORITY HAVING 1. DRAWINGS ARE DIAGRAMMATIC ONLY.THE LOCATION AND ROUTING OF 1. ALL EQUIPMENT IS LISTED FOR USE. CO .7 Y RACEWAYS SHALL BE DETERMINED BY THE CONTRACTOR UNLESS OTHERWISE 2. MAXIMUM VOLTAGE DOES NOT EXCEED 600VDC. Y U o JURISDICTION NOTED OR STANDARDIZED. 3. ANY EQUIPMENT <A P 2. ALL EQUATIONS ACCOUNT FOR WORST CASE CONDITIONS. I�ABLL BOR BEN W AND LISTED BY A RECOGNIZED ELECTRICAL TESTING Q 4= 2J 3. IF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT.WIRE.EQUIPMENT DEVICES.OVER-CURRENT PROTECTION,GROUNDING SYSTEMS,ETC.(ALL 4. AN INVERTER IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY EQUIPMENT AND MATERIALS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR OE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AM PROVIDING AND INSTALLING ALL MATERIALS AND SERVICES REQUIRED BY THE DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL / } STRICTEST CONDITIONS IN THE SPECIFICATIONS OR NOTED ON THE PLANS TO REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION O ENSURE COMPLETE COMPLIANCE WITH ALL CODES AND TO ENSURE THE NETWORK VOLTAGE HAS BEEN RESTORED. 0 U Ce Q LONGEVITY AND SAFETY OF THE OPERABLE SYSTEM. 5. ALL PV ARRAYS SHALL BE EQUIPPED WITH DC GROUND FAULT PROTECTION. f. J F (n APPLICABLE CODES 4. ALL OUTDOOR EQUIPMENT SHALL BE MIN NEMA SR RATED 5, 6. ANY AC COMPONENT SHALL MEET OR EXCEED THE AVAILABLE FAULT CURRENT V J LL METAL CONDUIT AND ENCLOSURES SHILL BE USED WHERE PV SOURCE OR CALCULATED AT THAT COMPONENT. OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING. 7. ALL MODULES AND ANY RELATED ROOF MOUNTED METALLIC EQUIPMENT SWILL D- Q co 6. MODULES SHALL NOT BE PLACED OVER ANY PLUMBING VENTS MID AT LEAST 8• BE PROPERLY GROUNDED, LC 0CN ABOVE FLUSH VENTS, S DC EQUIPMENT SHALL BE 600VDC RATED MINIMUM. 1— J I IN PV1 COVER PAGE T. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH ANY AND ALL 9. MARINGS SHALL BE PROVIDED TO INDICATE THAT ALL CONTACTS OF THE Z - I"- Z REQUIREMENTS GIVEN BY UTILITY COMPANIES. DISCONNECT EQUIPMENT MIGHT BE ENERGIZED. Q 0 8, FOR ADDITIONAL EQUIPMENT SPECIFICATIONS,SEE PROVIDED CUT SHEER. 10. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL V [O PV2 SITE PLAN 9, ALL LABELS AND MARKINGS SHALL BE ATTACHED ACCORDING TO BOXES OR JUNCTION BOXES/COAIBINER BOXES PER APPROPRIATE ` 1D J REQUIREMENTS BY NEC AND THE LOCAL All.).THE NU MAY HAVE SPECIAL JURISDICTIONAL REQUIREMENTS, LABEL REQUIREMENTS BEYOND THE SCOPE OF THIS DOCUMENT.THIS MAY 11, FOR ANY UNGROUNDED PV SYSTEM,A LABEL READING.WARNING- DATE PV3 MOUNTING PLAN ENCOMPASS LANGUAGE INCLUDING,BUT NOT IMBED TO,THAT FOUND IN NEC ELECTRICAL SHOCK HAZARD.THE DC CONDUCTORS OF THIS PHOTOVOLTAIC ARTICLES 690.51C).055 II(C121.690.11,690.53,690.35(F).890.54.890.84(BX7)And SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED•SHALL BE PLACED AT 10/14/2023 705.10. EACH JUNCTION BOX.COMBINER BOX.DISCONNECT AND DEVICE WHERE J PV4 STRUCTURAL DETAILS 10, ALL NEC REFERENCES SHALL BE DIRECTLY INTERCHANGEABLE WITH CEC ENERGIZED,UNGROUNDED CIRCUITS MAY BE EXPOSED WRING SERVICE. REFERENCES. 12,INVERTER(S)SHALL CONTAIN A GROUND FAULT DETECTION AND INTERRUPTION r DESIGNED BY. DEVICE. PVS-S.1 MOUNTING DETAILS 13. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND 0^A\/ STRUCTURAL NOTES: ELECTRICALLY CONTINUOUS. ZH OF,l4,1 '�/'v 14. THE POINT OF CONNECTION COMPLIES WITH APPLICABLE CECINEC. P� 45,^+1�� 1. MOUNTS ARE DIAGRAMMATIC AND EXACT LOCATION MAY GRANGE.BUT SHu L 15, BACKFED SOLAR BR E AKER(S(SHALL BE INSTALLED AT THE OPPOSITE END OF L PV6-6.1 ELECTRICAL DIAGRAMS THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN BREAKER (ti PAULK. 1BE ACCURATELY SPACED. II. ALL N1RE.VOLTAGES AMPERAGES AND EQUIPMENT IS SIZED ACCORDING TO l/)Lyry-L{/2. MOUNTS SHALL BE STAGGERED WIZEN NECESSARY TO EVENLY DISTRIBUTE TCHERNTEMPERATURE DEBATING AND LOCATION. PV7 MARKINGBLABELS LOAD AMONGST RAFTERS. 17. ONLY COPPER(CU')CONDUCTORS SHALL BE USED.CONDUCTORS SHALL BE STRUCTURAL 3. DO NOT SPLICE RAILS IN MIDDLE 50%OF SPAN BETWEEN TWO MOUNTS. N STRANDED OR SOLID WITH PROPERLY RATED CONNECTORS. 'ATTACHMENTS 16 DISCONNECT SHALL BE WIRED SO NO BLADES ARE ENERGIZED. ,\', SACIPAI • L J 19. ALL MODULES SHALL BE GROUNDED AS PER MANUFACTURER SPECIFICATIONS, O 20,ALL EQUIPMENT SHALL BE GROUNDED,INCLUDING BONDING JUMPERS WHERE �.�C NECESSARY ACROSS RAIL SPLICE PLATES TO BOND INDIVIDUAL PIECES OF �SS/ONALT MANUFACTURERS SPECIFICATIONS RAIL INDEX GENERAL NOTES PV1 1 i ARRAY 1 X ARRAY 2 8 TMLT:39• TILT:16° a w It AZIMUTH:285' AZIMUTH:85` In i V DRIVE WAY W J j a45 5• - a _ -. (._ 0 = a G--) r---.. ARRAY SPECIFICATIONS Q mMP , Z CO o Z :11 ; �'I METER MAIN COMBO J Z f] AC DISCONNECT FUSED W U K o Q i 1-1 INVERTER w o F 2® COMBINER PANEL Na J a W Qo�I— 1 MAIN SERVICE PANEL O W rn :.. 18"VENTILATION SETBACK 0 73 � 3'WIDE FIRE ACCESS PATHWAY m 3'x3'GROUND LADDER ACCESS POINT ^ M LEGEND W 5 w J N Y 0 O 111111111111111 NOTES: 1 U < 1. LOCATION OF JUNCTION BOX(ES), AC 0 J DISCONNECTS(S),AC COMBINER PANEL(S),AND 95,_ll. OTHER ELECTRICAL EQUIPMENT(S) RELEVANT }O TO PV INSTALLATION SUBJECT TO CHANGE 0 v re BASED ON SITE CONDITIONS. U w D 2.SETBACKS AT RIDGES CAN BE REDUCED TO g Q m 18 INCHES IN COMPLIANCE WITH IBC 12044. .2.1.2.: . 0 = N ! TOTAL PLAN VIEW AREA=1827.36 SOFT Z � TOTAL PV AREA=35(74 IN)(41.1 IN)/(144 IN^2) O a =739.2 SOFT V oo (739.2 SQFT/1827.36 SQFT)100=40.45% / DATE TOTAL PV AREA POPULATES 40.45%OF TOTAL ���4�2�23 PLAN VIEW AREA AND IS NOT WITHIN THE 33% 1. SWIMMING REQUIREMENT. i DESIGNED BY POOL onnv k�\,SH OF�SSq i PAUL K. QY�� -_- —-- I �STRUCTURAL PROPERTY LINE "�ONo.So'°° PV2 FSSALt`' w 1 — 3' WIDE FIRE ACCESS > $ PATHWAY- 2'-3" l.— 13'-5" 27'-4" -I +� l / Z \ 1-� III- .-�-r-. z °' f Q c �g '-F�--0---0----0=-0-' a. Q O� J Z N D • ( 011111 ! Z wa 1 1 1 0 CO ap MP1 2 O J TILT: 39• o AZIMUTH:265' I' 38'-2" )I [ I i ! j _j -I W ,_ w u� �I • • --�•- -} _--4- -•• �� -- -�- - • >" Y o Q j 01 ! o Q 2J TO • • -+ �� -• - lam♦ 1-•-Li t• /� >-- • • i♦ rtl + mot +-ttti l 0 0 CC a II III 1 _i V (1)ui D • • • • •——-•- - • • • • g > a - 0.0H OFMgss9 Z J I- MP2 PAUL K. O R ca Z TILT: 16° e.i ZACHER �V01 J SOLAR MODULE "PZSE advises that best I •,...._ AZIMUTH:85° STRUCTURAL / 1 practice in snow load areas is R 9 DATE to install staggered irt•� � " 3"2i 10/14/2023 attachments" %� >V"\' J TYPE DESCRIPTION QUANTITY `SS/OVALS" / DESIGNED BY: MODULE .REC SOLAR REC405AA PURE BLACK SERIES(405W) 35 ROOF SPECIFICATION '- OMV J SOLAR MODULE DC OPTIMIZER S440 SOLAREDGE POWER OPTIMIZER 35 ROOF MATERIAL ASPHALT SHINGLE N • Applicable Codes: 780 CMR,ASCE 7-10 and NDS-15 111) • Ground Snow Load: 40 lb/sqft INVERTER SOLAREDGE SE10000H-US INVERTER 1 RAFTERS 2"X 10"@ 16"O.C. • Basic Wind Speed: 117 mph,Exposure Category B DISCONNECT 60A FUSED AC DISCONNECT 1 ROOF CONDITION GOOD PV3 \ IRONRIDGE XR10 __ IRONRIDGE L FOOT ,,- J a r. \ \ \ / ~ co = W - IRONRIDGE FLASH FOOT a g z N WOOD SHEATHING SHINGLE FLASHING z = o /� 5/16"x4"STAINLESS z w ¢2 RAFTERS STEEL LAG SCREW 0 O z \ 01 N .. / w .- w F J IRONRIDGE XR10 N Y 0 0 a IRONRIDGE L FOOT a 4 o s 0 o ix g SOLAR MODULE _ 0 N DI- D IN WOOD SHEATHING 0 J 0 d o z /'*11111ide - IRONRIDGE FLASH FOOT c DATE IH111 1 -/11110 SHINGLE FLASHING 10/14/2023 ''' c DESIGNED EiY 1 5/16"x4"STAINLESS 0,01-kOFAW,o9 ` OMV RAFTERS STEEL LAG SCREW /) ZA CH ER Y� STRUCTURAL y STRUCTURAL ATTACHMENT DETAILS PV4 s d ..•.......... %sr - -- ... D. Project Detaile 8 O Name .%rcp0h CleyMwQI Date 1011b202:! Bill of MaterialsU Louunn 92 Glendale Road.Noram mlen.MA 01062 To.modules OS pN / Module NEC Sobs REGUSAA Cue(9Gnml Total wens 1a.115 Rails L Splices - T01/I QXI / Z Olmensiorrs Dimensions.11.69"2400'k 1.1r(18210mm.1015.8mm%].(mein) Anecnments 71 %R-101685 0 0 22 am,. ' _ ASCE t.10 Rails psr,pw 2 am WO r^ Q_ Be.R.ao-s.ap.R10 1 0 12 Q Clamps&Grounding � m I-.L UFO-CL-0I-BILLI D ..2) Z V ...sr S ..30FBl ...sr aaae.,mAiM en.a 0 20 Z U o O LWAi-AI Ct Gm..Lib LoL.P.. ° 5 = Z;%R Z ...1Q AR.[amMds = W <2 (NmawUvi'BS 0 0 Z 0 1 .p. 2 -D J BIOW SQ02-A1 0 11 0 Swat eEa 6aaa.q..i,.e N Aaaagde \ m / QOO-00181 0 4 Q0 \ / .. System weight Load assumptions W > W Tal.l system weight 1.789.6las Wind exposure B 0 Wei0hdM m tachent 26.2 Ns wind speed 117 mph >" Y Y a R.ckmg weight 2019 Ms 0,000 l snow load a0 0s1 (1) Q O Dist...weight 2s Pa Attachment spacing porous A0- • \ 0 / Pool Information • Roo,Wp Al Faintly Comp Stonple Rrrot m n Comp riteal Co SI- e �0 V Q Q Building.pat 306 Pool alpr5ment L-0ofe(LAO BOX) I . J D MI S00nered enrichments yes5 a0 > > N Roof slope 29' atpcment hardware Square 0 Q ,- I—Z Risk cM II Specific�ry 0_/5 0 Q. 0 Z (U _✓ Span Details%R10-POrttae DATE 2mn. M..SP. Al.[.ntllewer 10/14/2023 • \ J 2 5 3 z 1 /DESIGNED BY ) 5 3- z l- �P`tHDF�,�9 ` 0 M V , /� PAUL K. ZACHER 1 - ___...__�_..,,_,._ �STRUCTURAL• m ` 8 W1 oei k -,S510NAL 1 PV5 1- 1 I C (E)200A J E$ 200A METER MAIN d MAIN SERVICE COMBO PANEL 120/240V SOLAREDGE 60 AC 120/240V r- 1 STRING OF SE10000H-US DISCONNECT 11 MODULES INVERTER FUSED (E)200A410 co 0 • 2�nn a DC UNGROUNDED Q V M W/OPTIMIZERS -EH-1- 1 • IX D a 60A/2P r . U' m F 1 STRING OF ¢II • .)E)200A u z N 6 12 MODULES �I � ° • � LOAD SIDE TAP -I• C0 o W/OPTIMIZERS P'I PI 01 • •/ V = w • , Lail o 2 1 STRING OF 12 MDULES O O O . J q iuz W/OPTIMIZERS — © 11 IT w --GEC I ' �� M I- J U) Y U O O J ce a U J ui 7 I.." 7 = N_ Z d } CONDUCTORS AND CONDUIT N \ MODULES ` INVERTERS) ` OTHER EQUIPMENT J \8 z CD l O (35)REC SOLAR REC405AA PURE SOLAREDGE SE10000H-US DATE 10/14/202 (6)#10 PV WIRE 60A FUSED AC DISCONNECT (1)#6 THHN GND BLACK SERIES(405W)SOLAR MODULE MAX AC OUTPUT:42 A \. 60A 3 3/4"EMT WATTS STC:405W INVERTER OCPD CALC:(42)X 1.25=52.5A STRUCTURAL ONLY t DESIGNED BY \ O (3)#6 THHN ISC:10.14A MIN OCPD:60A ,jHOFKi OMV (1)#6 THHN GND ky \ 1 3/4"EMT IMP:9.56A WIRE AMPACITY:65A @75°C TERMINAL PAUL K. TEMPERATURE CORRECTION FACTOR: /I ZACHER Yn VOC:48.9V O (3)#6 THHN 31°-35°C=0.94 STRUCTURAL, k FA(1)#6 THHN GND VMP:42.4V CORRECTED WIRE AMPACITY:61.10A `` •o S,M ��. %srEC�' PV6 l \ / \ l a1 (E)200A 9 200A METER MAIN -J MAIN SERVICE COMBO a, PANEL 120/240V 120/240V \ SOLAREDGE 60A AC LOAD SIDE TAP \ 1 STRING OF SE10000H-US DISCONNECT UM / z 11 MODULES INVERTER FUSED 2 2 ~a W/OPTIMIZERS_ 1I DC UNGROUNDED f 60A/2P t (E)200A g (9 4 — — ■—■ ry 1 STRING OFIII �� , • Z 12 MODULES r �� Ir , • Q U w o W/OPTIMIZERS • • U ¢ f—L I—� o W ¢2 1 STRING OF L 6. ; • (� Q z 12 MODULES O © J W/OPTIMIZERS — — { © L © t1 W O N cn GEC \ 1 M\ W o W I— J N Y U 0 O (W > ' O U 2 ¢ U - ui D 1— _ /- CONDUCTORS AND CONDUIT ` MODULES ` INVERTER(S) ` ' OTHER EQUIPMENT p a o > ` J ` ) I ) ) c) r, z O (35)REC SOLAR REC405AA PURE SOLAREDGE SE10000H-US co J DATE (6)#10 PV WIRE 60A FUSED AC DISCONNECT / ` (1)#6 THHN GND BLACK SERIES(405W)SOLAR MODULE MAX AC OUTPUT:42 A 3/4"EMT ` / 10/14/2023 WATTS STC:405W INVERTER OCPD CALC:(42)X 1.25=52.5A STRUCTURAL ONLY / DESIGNED By \ © (1)#6THHN (1)#6 THHN GND ISC:10.14A MIN OCPD:60A O�A\ ZN�FM IVI V 3/4"EMT IMP:9.56A WIRE AMPACITY:65A @75°C TERMINAL gssq TEMPERATURE CORRECTION FACTOR: (.1 PAUL K. C5% VOC:48.9V ZACHER (3)#6 THHN 31°-35°C=0.94 (1)#6 THHN GND VMP:42.4V CORRECTED WIRE AMPACITY:61.10A STRUCTURAL y k O 1"EMT .\ ,N. ;Mig11°� °- ONAL / e/ PV6.1 INVERTER AC DISCONNECT MAIN SERVICE PANEL NEC 705.12(D)(4)),690.56(B) NEC 690.17(4)GROUNDED SYSTEMS NEC 690.14(CX2) 40 PHOTOVOLTAIC DISCONNECT WARNING J ,o WARNING POWER IS BEING SUPPLIED TO THIS a ii ELECTRIC SHOCK HAZARD. FOR UTILITY OPERATIONS PANEL FROM THE UTILITY AND A o DO NOT TOUCH TERMINALS. NEC 690.54 SOLAR PV SYSTEM. TERMINALS ON BOTH LINE AND NEC 705.12(D)(7) Z LOAD SIDES MAY BE ENERGIZED IN RATED AC OUTPUT CURRENT: 42 A -— _ NOMINAL AC VOLTAGE: 240 V THE OPEN POSITION. WARNING ' INVERTER OUTPUT CONNECTION ea m i N NEC 690.14(C)(2) NEC 690.56 DO NOT RELOCATE THIS o OVERCURRENT DEVICE °6 _1 Z PHOTOVOLTAIC DC DISCONNECT EMERGENCY RESPONDER z = o THIS SOLAR PV SYSTEM LABEL TO BE INSTALLED DIRECTLY NEXT TO PV BACKFEED Y a Lu< BREAKER.IF INSTALLED ANYWHERE ELSE ON DEADFRONT a, w a0 EQUIPPED THENAPERMANENTARROWFROMLABELPOINTINGTO a N z WITH RAPID SHUTDOWN PVBACKFEEDBREAKERREQUIRED. 2 O, r . TURN RAPID SHUTDOWN PHOTOVOLTAIC SWITCH TO THE NEC690.54 m "OFF"POSITION ONLY CONDUCTORS INSIDElail' SYSTEM EQUIPPED WITH BUILDING OR OFF THE 'RATED AC OUTPUT CURRENT: 42 A ROOF WILL SHUT DOWN M v RAPID SHUTDOWN • ,„,�„WI NOMINAL AC VOLTAGE: 240 V w w NEC 690.14(C)(2) N U U 00 NEC 690.53 #INVERTER 1 CONDUIT, RACEWAYS, PHOTOVOLTAIC AC DISCONNECT / o a PHOTOVOLTAIC ARRAY p o a DC DISCONNECT ENCLOSURES, CABLE -- W OPERATING CURRENT: 27 A g c ¢ g OPERATING VOLTAGE: 400 ASSEMBLIES Z J r .- MAX. SYSTEM VOLTAGE: 480.0 V O a ci z SHORT-CIRCUIT CURRENT: 45.0 A & JUNCTION BOXES �" - J DATE NEC 690.31(E)(3)CONDUIT 10/14/2023 r l Warning: Photovoltaic Power Source STRUCTURAL ONLY r DESIGNEDBV NEC 690.35(F)UNGROUNDED SYSTEMS JUNCTION BOX yytHOFMq�9�i OMV (*iACH ZER WARNING 1 STRUCTURAL m ELECTRIC SHOCK HAZARD. ` .MR194 THE DC CONDUCTORS OF THISk oZsSD : -� PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. PV7 7 1 STATE OF NEW YORK WORKERS'COMPENSATION BOARD CERTIFICATE OF INSURANCE COVERAGE UNDER THE NYS DISABILITY BENEFITS LAW PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier I a. Legal Name and Address of Insured(Use street address only) lb.Business Telephone Number of Insured PLUGPV LLC (518)948-5316 630 7th Avenue I c.NYS Unemployment Insurance Employer Registration Troy,NY 12182 Number of Insured ld.Federal Employer Identification Number of Insured or Social Security Number 820674758 2. Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) Standard Security Life Ins. Co. of NY 3b. Policy Number of entity listed in box"I a": R89233-000 City of Northampton 212 Main St, 3c. Policy effective period: Northampton, MA 01060 3/28/2023 to 3/28/2024 4. Policy covers: a. ❑x All of the employer's employees eligible under the New York Disability Benefits Law b. ❑ Only the following class or classes of the employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insufi3nce coverage as desc 'bed above. Date Signed October 3,2023 By rr (A ZN (Signature of in urance carver's authorized re sentative or NYS Licensed Insurance Agent of that insurance carrier) 518-793-3131 President Telephone Number Title IMPORTANT: If box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If box"4b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability Benefits Law.It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,20 Park Street,Albany,New York 12207. PART 2. To be completed by NYS Workers'Compensation Board(Only if box "4b"of Part 1 has been checked) State Of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title _ Please Note:Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (5-06) I Additional Instructions for Form DB-120.1 By signing this form,the insurance carrier identified in box"3"on this form is certifying that it is insuring the business referenced in box "la"for disability benefits under the New York State Disability Benefits Law.The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed as the certificate holder in box"2". This Certificate is valid for the earlier of one year after this form is approved by the insurance carrier or its licensed agent,or the policy expiration date listed in box"3c' Please Note:Upon the cancellation of the disability benefits policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of NYS Disability Benefits Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Disability Benefits Law. DISABILITY BENEFITS LAW §220. Subd. 8 (a) The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in employment as defined in this article,and not withstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits for all employees has been secured as provided by this article. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any disability benefits to any such employee if so employed. (b) The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in employment as defined in this article, and notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an insurance carrier is produced in a form satisfactory to the chair,that the payment of disability benefits for all employees has been secured as provided by this article. DB-120.1(5-06)Reverse SOLAR'S MOST TRUSTED R E C " , t r_ Fli I ' s rr ! Ir f . REE ALpH FUR iiiiiii, oc ., ,_ . B : . . -RODUET SPEDFl A II EXPERIENCE REC Ilk\' tit 400 WP1r, 25 YEAR PRoTRUST I WARRANTY 20.0 WFT '4'= LEAD-FREE ELIGIBLE ROHS COMPLIANT PERFORMANCE 411 REC PRODUCT SPECIFICATIONS ..� SOLAR'S MOST TRUSTED . 1azl 1[71.7t0.n .- 'CERTIFICATIONS �28 11.11 90 901[35.5] 460 118.11 ° - ✓, IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) + • 15014001:2004,ISO9001:2015,OHSA518001:2007,IEC 62941 ��� noo[a3.31 i-- ) °® C E D 6.0±0.2 [0.24±0.01] S 'WARRANTY s o II " Standard RECProTrust so Installed by an REC Certified No Yes Yes c 11t0.2 Solar Professional - *4[0.43±0.011 System Size All c25 kW 25-500 kW i; zostos Product Warranty(yrs) 20 25 25 i _.v,. Power Warranty(yrs) 25 25 25 1200[47.21 Labor Warrant (yrs) 0 25 10 r, [o.amo.ozl l �w a Y IY ) 1 Power in Year 98% 98% 98% a t f Annual Degradation 025% 025% 0.25% 22.5[0.91 671±3[26.4±0.121 ....g _._.__.. ............... as[t s] Power in Year 25 92% 92% 92% i i 30[1.21 See warranty documents for details.Conditions apply Measurements in mm(in) 'GENERAL DATA 'MAXIMUM RATINGS 132ha1f-cut RECheterojunctioncells Staubli MC4PV-KBT4/K5T4,12AWG(4 mm2) Operational temperature: -40...+185°F(-40...+85°C) Cell type: with lead-free,gapless technology Connectors: In accordance with IEC 62852 Maximum system voltage' 1000V 6 strings of 22 cells in series IP68 only when connected Maximum test load(front): +7000Pa(146lbs/sgft)° Glass: 0.13 in(3.2 mm)solar glass with Cable: 12AWG(4mm2)PV wire,43+47in(1.1+1.2m) anti-reflection surface treatment accordancewithEN50618 Maximum testload(rear): -4000Pa(83.51bs/sgft). Backsheet: Highly resistant polymer(black) Dimensions: 71.7 x 40 x1.2 in(1821 x 1016 x 30 mm) Max series fuse rating: 25 A Max reverse current: 25A .o Frame: Anodized aluminum(black) Weight: 45 lbs(20.5 kg) 'See installation manual for mounting instructions. 3-part,3bypassdiodes,IP67rated Designload-Testload/1.5(safetyfactor) Junction box: in accordance with IEC 62790 Origin: Made in Singapore N ' ELECTRICAL DATA Product Code':RECxxxAA Pure Black 'TEMPERATURE RATINGS' o Power Output-PMAX(Wp) 385 390 395 400 405 Nominal Module Operating Temperature: 44°C(±2°C) Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 Temperature coefficient of PMAX: -0.26%/°C » S Nominal Power Voltage-VM,p(V) 41.2 41.5 41.8 42.1 42.4 Temperature coefficient ofVoc: -0.24%/°C F Nominal Power Current IMpv(A) 9.35 9.40 9.45 9.51 9.56 Temperature coefficient of Isc: 0.04%/°C N tit Open Circuit Voltage-Voc(V) 48.5 48.6 48.7 48.8 48.9 'The temperature coefficients stated are linear values Short Circuit Current-Isc(A) 9.99 10.03 10.07 10.10 10.14 Power Density(W/sq ft) 19.3 19.6 19.8 20.1 20.3 'LOW LIGHT BEHAVIOUR Panel Efficiency(%) 20.8 21.1 21.3 21.6 21.9 Typical low irradiance performance of module at STC: RI -___. - _.-------- ni Power Output-PMAx(Wp) 293 297 301 305 309 » < _ ae s i- Nominal Power Voltage-VMp,(V) 38.8 39.1 39.4 39.7 40.0 c xNominal Power Current-IMp,(A) 7.55 7.59 7.63 7.68 7.72 - .- .-----_ 4 Z it Open Circuit Voltage-Voc(V) 45.7 45.8 45.9 46.0 46,1 °.. . .. .- - -- ,» a Short Circuit Current-Isc(A) 8.07 8.10 8.13 8.16 8.19 Irradiance(W/m') a Values at standard test conditions(STC:air mass AM 1.5,irradiance 10.75 W/sq ft(1000 W/m2),temperature 77°F(25°C),based on a production spread with a tolerance of PM,.,Voc 8/Is,t3%within one watt class.Nominal nodule operating temperature(NMOT:air mass AM 1.5,irradiance 800 W/ma,temperature 68°F(20°C),windspeed 3.3 ft/s(1 m/s).`Where xoc indicates the nominal power class(P„A„)at STC above. Founded in 1996,REC Group is an international pioneering solar energy ®\ ^EC company dedicated to empowering consumers with clean,affordable I� solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www.recgroup.com panels it manufactures. Headquartered in Norway with operational Qa , 1 headquarters in Singapore,REC also has regional hubs in North America, i Europe,and Asia-Pacific. ii `1 Power Optimizer O For Residential Installations S440 / S500 / S500B 25 YEAR WARRANTY O mt, 70 Enabling PV power optimization at the module level / Specifically designed to work with SolarEdge / Mitigates all types of module mismatch loss,from residential inverters manufacturing tolerance to partial shading / Detects abnormal PV connector behavior, / Faster installations with simplified cable preventing potential safety issues* management and easy assembly using a single bolt I Module-level voltage shutdown for installer / Flexible system design for maximum space and firefighter safety utilization I Superior efficiency(99.5%) / Compatible with bifacial PV modules 'Functionality subject to inverter model and firmware version solaredge.com solar • / Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 5500B UNIT INPUT Rated Input DC Powerl'1 440 I 500 W Absolute Maximum Input Voltage(Voc) 60 125 Vdc MPPT Operating Range 8-60 12.5-105 Vdc Maximum Short Circuit Current(Isc)of Connected PV Module 14.5 I 15 Adc Maximum Efficiency 99.5 Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer I 1±0.1 I Vdc STANDARD COMPLIANCE(Z) EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3,CISPR11,EN-55011 Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions(W x L x H) 129 x 155 x 30 I 129 x 155 x 45 mm Weight(including cables) 655 gr Input Connector MC4131 Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+)2.3,(-)0.10 m Operating Temperature Range141 -40 to+85 -C Protection Rating IP68 Relative Humidity 0-100 % (1)Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power.Modules with up to+5%power tolerance are allowed. (2)For details about CE compkance,see Declaration of Conformity-CE. (3)For other connector types please contact SolarEdge. (4)For ambient temperature above+70°C power de-rating is appked.Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge SolarEdge Home Three Phase Three Phase for Three Phase for Inverter' Wave Single Phase SExxI<-RWB 230/400V Grid 277/480V Grid Minimum String Length S440,SSOO 8 9 16 18 (Power Optimizers) S500B 6 8 14 Maximum String Length(Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is See141 See161 13500 15000 W less than 2,000W) Parallel Strings of Different lengths or Orientations Yes (5)h is not allowed to mix S-series and P-series Power Optimizers in new installations. (6)If the inverter's rated AC power s maximum nominal power per string,then the maximum power per string wiN be able to reach up to the inverters maximum input DC power. Refer to Application Note:Sinale Strina Design Guidelines. ^ uss r 4 �s� ' r O ' . -4 c � , or El-II C' I- C Elt '45mm for 550011 &�SolarEdge Technologies,Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE we trademarks or registered trademarks of SolarEdge Technologies,Inc. C E RoHS All other trademarks mentioned herein are trademarks of their respective owners.Date:September 22,2022 DS.000091-ENG.Subject to change without notice. Single Phase Inverter Z •with HD-Wave Technology m for North America 75_1 SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR 711:11 0 WARRANTY O O 0 0 O 0 • solar= ,.}j� solar,5i.7 _}{a U a . O O O 0 0 0 Optimized installation with HD-Wave technology / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring I Fixed voltage inverter for longer strings / Optional: Faster installations with built-in consumption metering (1% accuracy) and / Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5%accuracy, for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com solar • • / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US I SE7600H-US SE10000H-US SE11400H-US • APPLICABLE TO INVERTERS 1 SEXXXXH-XXXXXBXX4 WITH PART NUMBER OUTPUT Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V ! VA 3300 @ 208V 5000 @ 208V 10000 @ 208V Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA 3300 @ 208V 5000 @ 208V 10000 @ 208V AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac (211-240-264) AC Output Voltage Min.-Nom.-Max. - ✓ - ✓ - _ ✓ Vac (183-208-229) AC Frequency(Nominal) 59.3-60-60.50i Hz Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current @240V Maximum Continuous Output - 16 24 48.5 A Current @208V Power Factor 1,Adjustable-0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V° 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V14 - 9 - 13.5 - - 27 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V Nighttime Power Consumption <2.5 W (1)For other regional settings please contact SolarEdge support (2)A higher current source may be used;the inverter will limit its input current to the values stated / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Metering,ANSI C12.20 Consumption metering OptionalD' Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020,690.12 STANDARD COMPLIANCE Safety WW1' Grid Connection Standards IEEE1547,Rule 21,Rule 14(HO Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to+140/-40 to+60i4) 'F/'C Protection Rating NEMA 4X(Inverter with Safety Switch) (3)Inverter with Revenue Grade Meter P/N:SE mxH-US000BNC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SE000tH-US000BNI4.For consumption metering,current transformers should be ordered separately:SEACT0750-200NA-20 or SEACT0750-400NA-20.20 units per box (4)Full power up to at least 50'C/122'F;for power de-rating information refer to:https://wwwsolaredge.com/sites/default/flles/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring 1\ 1 1 Grid CT L1 N L2 i l► Shielded CAT5e cable i►_4 L1 • 410.'/ \` AC Conduit O SolarEdge Technologies,Inc.At rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BR SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.AR Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date.12/2020N01/ENG NAM.Subject to change without notice. Tech Brief Zalli IRONRIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing t enough to buckle a panel frame. ,l` { XR Rails are the structural backbone preventing f these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability -,_ requires fewer roof attachments, - reducing the number of roof s 1 , IliII penetrations and the amount ! : .,--- of installation time.,., ..414.77, �. el T. (00--- ,_ Force-Stabilizing Curve Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails is specially designed to increase strength in both ....o."..'-'/ directions while resisting the twisting.This unique feature ensures greater security during extreme weather and a longer system lifetime. \\444444:48.04, -- Compatible with Flat& Pitched Roofs Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series 16. compatible with r). �� a range of tilt leg aluminum alloy,then protected with an FlashFoot and n options for flat anodized finish.Anodizing prevents surface other pitched roof I 1 roof mounting and structural corrosion,while also providing attachments. applications. a more attractive appearance. 01111 Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. rl■ — XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail. It supports a range of solar mounting rails. It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF) Wind (MPH) 4' 5' 4" 6' 8' 10' 90 120 None • 140 XR10 XR1000 160 90 • 120 20 140 160 90 30 160 90 40 160 80 160 120 160 table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. ©2020 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.20 ,��� Cut Sheet IRONRIDGE L-Foot • 0 <C ITEM NO DESCRIPTION QTY IN KIT 1 FOOT, EXTRUDED L-SLOTTED 4 PART NUMBER DESCRIPTION FM-LFT-003 Kit, 4Pcs, Slotted L-Foot, Mill FM-LFT-003-B Kit, 4Pcs, Slotted L-Foot, Black 1) Foot, Extruded L -Slotted .42 (7`, 1.92 .35 - - - .94 H- .40i .11 1.22 3.00 ` T .31 1.92-�- �1.88-e- v1.11 DocuSign Envelope ID:C3045769-DC37-4CF3-987C-899A2489036F REVISED SOLAR SYSTEM WORK ORDER THIS WORK ORDER AGREEMENT("Work Order")to the Channel Partner Agreement between Sunnova Energy Corporation("Sunnova")and PlugPV LLC("Contractor")is made and entered into by and between Sunnova and Contractor for the design,engineering, procurement,construction,installation,and testing of the Solar System described in this Work Order. Each Party represents that the representations and warranties of such Party in Article 19 of the Channel Partner Agreement are true and correct in all material respects as of the date of signature by such Party,as indicated below and that Contractor is not in default in any respect. Capitalized terms used in this Work Order have their respective meanings set forth in the Channel Partner Agreement. REVISED on: Sunnova and Contractor agree as follows: The Solar System that is the subject of this Work Order shall be designed,engineered,procured, constructed,and installed as follows: Sunnova System ID GK006686895 Customer Name JOSEPH CLAYBAUGH Total Job Amount $62,884.16 Sunnova Purchased Equipment $0.00 Amount Contract Amount($) $62,884.16 Job Site Address 92 GLENDALE RD,NORTHAMPTON,MA,01062,United States Job Site Utility Company National Grid-Massachusetts System Size(STC DC kW) 14.175 kW Incentives(Rebate)Authority Incentives(Rebate)Amount $0.00 Equipment Arrays REC Solar REC405AA Pure(17) SolarEdge Technologies Inc.SE10000H-US000BN14(Inverter)(1) Equipment Arrays REC Solar REC405AA Pure(18) SolarEdge Technologies Inc. SE10000H-US000BN14(Inverter)(0) Monitor Model and Count SolarEdge Technologies Inc.SolarEdge Built-in Consumption Monitor(BE14, BNI4,BNC4,BBL14)(1) Racking IronRidge Year 1 Annual Production 10,565.48 kWh Contractor shall achieve Substantial Completion by the Guaranteed Substantial Completion Date and achieve Final Completion promptly thereafter unless otherwise excused under the Channel Partner Agreement. Should Contractor fail to achieve Substantial Completion or Final Completion, Sunnova shall provide Contractor with written notice of such failure and request for action. Contractor shall acknowledge such notice in writing to Sunnova within one (1) business day of receipt of such notice and complete the Work within ten(10)days of receipt of such notice. If Contractor fails to deliver such acknowledgement to Sunnova or perform such Work within such time,Sunnova or its designated contractors shall have the right, but not the obligation,to complete such Work for Contractor and charge or set off Sunnova's costs and expenses for performing such Work. If Customer's Solar System produces energy over twenty-four (24) consecutive hours before the permission to operate being issued by the utility, Contractor will within seventy-two (72) hours after notification from Sunnova, either: (1) provide Sunnova with acceptable documentation that permission to operate has been issued by the utility; or (2) turn off Customer's Solar System to eliminate such pre-permission-to-operate Copyright©2015 by Sunnova Energy Corporation All rights reserved. DocuSign Envelope ID:C3045769-DC37-4CF3-987C-899A2489036F production. If Contractor fails to take either of these actions, Contractor will be liable to Sunnova for Customer's monthly charges from Sunnova for the month in which such unauthorized production occurs. • Contractor will have Customer's Solar System turned on and successfully reporting in the Sunnova monitoring platform within seven (7) days of the issuance of the permission to operate by the utility. If Contractor fails to do so, Sunnova or its designated contractor may, in its sole discretion, have the Customer's System turned on,and Contractor will pay Sunnova's costs and expenses for such completion. If Sunnova or its designated contractors, at Sunnova's discretion, perform the following or similar actions during any Inspection, Sunnova may charge Contractor a flat fee, not to exceed $200: minor general repairs, re- secure PV Conductors, replace/ repair screws at J-box, BOS, install stress relief on conductors, re-secure module clamp, re-secure racking component, repair/reseal roof penetration, repair/replace flashing, replace fuses/circuit breakers, troubleshoot inverter, replace/install NEC placards, rodent removal, repair minor roof damage, secure conduit to structure. If Customer notifies Sunnova of an emergency requiring Warranty Services, Sunnova will provide Contractor with notice of such Warranty Services request. Contractor will provide such Warranty Services as promptly as reasonably practicable. If Contractor is unable or unwilling or otherwise fails to provide such Warranty Services to Sunnova's satisfaction, Sunnova may, in its sole discretion, have another designated contractor perform such Warranty Services and may charge Contractor for any costs, fees, or expenses of such Warranty Services. If Customer notifies Sunnova of a non-emergency requiring Warranty Services, Sunnova will notify Contractor of such request. Contractor will acknowledge in writing to Sunnova within two (2) days (except in the case of an interruption or loss of service,and then one(1)day)and perform such Warranty Services promptly, but in no event more than ten (10)days (except for loss or interruption of service, which shall be within three (3) days). If Contractor fails to perform such Warranty Services by such time, Sunnova or its designated contractors will may, in its sole discretion, have such Warranty Services completed by another contractor and charge or set off Sunnova's costs and expenses for having such Warranty Services performed. The remedies provided for in this Work Order shall be in addition to all other rights and remedies Sunnova may have under the Channel Partner Agreement (including, without limitation, Liquidated Damages) or any other agreement with Contractor,or under law or equity. IN WITNESS WHEREOF,the Parties have caused this Work Order to be executed as of the respective dates set forth below. SUNNOVA ENERGY CORPORATION PlugPV LLC By: Shane,NoLa.w liA43-11C Name: Shane Nolan Date: October 18, 2023 John Santo Salvo Authorized Signatory Sunnova Energy Corporation Copyright©2015 by Sunnova Energy Corporation All rights reserved.