Loading...
PlansSHEET # T-1 T-2 PV-1 & 1.1 PV-2 PV-3 E-1 E-2 S-1 S-2 S-3 S-4 S-5 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET COORDINATES: 42.318640, -72.665424 SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR T1 COVER SHEET AERIAL VIEW SCOPE OF WORK TYPE OF SYSTEM: ROOF MOUNT SYSTEM SIZE: STC: 39 X 380 W = 14.820kW PTC: 39 X 348.9 W = 13.607kW (39)SOLARIA POWER X-380R-2B (380W) [BLK] MODULE (39)ENPHASE IQ8PLUS-72-2-US MICROINVERTERS (1)60A KNIFE AC DISCONNECT (1)60A FUSED AC DISCONNECT WITH 60A FUSES (1) 125A ENPHASE IQ COMBINER 4/4C BOX MSP UPGRADE: NO MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: UNIRAC FLASHLOC FOR COMP SHINGLE ROOF RACKING TYPE: UNIRAC SOLARMOUNT - ROOF MOUNT RACKING HARDWARE PAUL ST LAURENCE JR RESIDENCE NEW PHOTOVOLTAIC ROOF MOUNT SYSTEM PROJECT - 14.820 kW DC / 11.310 kW AC PROJECT INFORMATION PROPERTY OWNER NAME:PAUL ST LAURENCE JR CONTRACTOR NAME: COMPLETE SOLAR DESIGN SPECIFICATIONS OCCUPANCY:R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL WIND EXPOSURE: B PHONE:NORTHAMPTON UTILITY:NATIONAL GRID APPLICABLE CODES & STANDARDS 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2021 INTERNATIONAL PLUMBING CODE (IPC) 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2020 NATIONAL ELECTRICAL CODE (NEC) 2021 INTERNATIONAL FIRE CODE (IFC) TYPE OF INTERCONNECTION: LINE SIDE TAP IN THE MSP 1.1.PROJECT NOTES: 1.2.THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4.GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.5(A) 1.5.ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.7.ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.8.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.9.SCOPE OF WORK: 1.10.PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11.WORK INCLUDES: 1.12.PV ROOF ATTACHMENTS - UNIRAC FLASHLOC FOR COMP SHINGLE ROOF. 1.13.PV RACKING SYSTEM INSTALLATION - UNIRAC SOLARMOUNT ROOF MOUNT RACKING HARDWARE 1.14.PV MODULE AND INVERTER INSTALLATION - SOLARIA POWER X-380R-2B (380W) [BLK] MODULES / ENPHASE IQ8PLUS-72-2-US MICROINVERTERS. 1.15.PV EQUIPMENT GROUNDING 1.16.PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17.PV LOAD CENTERS (IF INCLUDED) 1.18.PV METERING/MONITORING (IF INCLUDED) 1.19.PV DISCONNECTS 1.20.PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21.PV FINAL COMMISSIONING 1.22.(E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23.SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24.SITE NOTES: 1.25.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 1.27.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 1.29.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 1.30.EQUIPMENT LOCATIONS: 1.31.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 1.32.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 1.34.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 1.35.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 1.36.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37.STRUCTURAL NOTES: 1.38.RACKING SYSTEM 1.39.PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40.A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44.WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45.WIRING & CONDUIT NOTES: 1.46.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47.CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 1.48.VOLTAGE DROP LIMITED TO 1.5%. 1.49.DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15 1.51.GROUNDING NOTES: 1.52.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 1.54.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 1.55.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. 1.56.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 1.59.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 1.60.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.5 IN GENERAL AND NEC 690.5 (A)(1) SPECIFICALLY. 1.61.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64.RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [NEC 690.12]. LOCATION OF LABEL ACCORDING TO AHJ 1.65.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 1.66.MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 1.67.IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. 1.68.ELECTRICAL INTERCONNECTION NOTES: 1.69.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF THE BUSBAR RATING. 1.70.WHEN THE SUM OF THE PV SOURCES EQUALS >100% OF THE BUSBAR RATING, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD. 1.71.AT MULTIPLE PV OUTPUT COMBINER PANEL, THE TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED. 1.72.SUPPLY-SIDE TAP INTERCONNECTION SHOULD BE WITH SERVICE ENTRANCE CONDUCTORS. 1.73.BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING. SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR T-2 PLAN NOTES N 3'3' 3'3' 3' 3' 371'-1" 64'-1" 266'-4" 35'-4" 153'-4" 191'-8" LEGEND CONSTRUCTION NOTES PV INTERCONNECTION POINT. LOCATION OF MAIN SERVICE PANEL & AC DISCONNECT 2 MOUNTED ON INTERIOR WALL & UTILITY METER, AC DISCONNECT 1 & COMBINER BOX MOUNTED ON EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE. NEW SOLAR PANELS (39) SOLARIA POWER X-380R-2B (380W) [BLK] WITH AN ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS MOUNTED TO THE BACK OF EVERY MODULES MOUNTED ON COMP SHINGLE ROOF SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR PV-1 SITE PLAN LAYOUTSCALE: 1/64" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 14.82 kW DC LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 ROOF OBSTRUCTIONS JB (N)CONDUIT RUN CB COMBINER BOX Roof Azimuth: 70° Roof Tilt: 20° Roof Section 1 ACD AC DISCONNECT MSP MAIN SERVICE PANEL UM UTILITY METER 1.SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2.THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE IBC SECTION 1609 TO WITHSTAND A BASIC WIND EXPOSURE B. 3. THE ROOF MEMBERS ARE 2"X 6" TRUSSES AT 16" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4.THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5.ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6.ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (IRC R324.6, IBC 3111.3.4) 6.1.LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2.LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. 7.SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN COMPLIANCE WITH IBC/ IFC 1205.2.1.2 TOTAL PLAN VIEW AREA = 2026.2 SQFT TOTAL PV AREA = 39(67.8 IN)(44.7 IN)/(144 IN^2) = 820.80 SQFT (820.80 SQFT/ 2026.2 SQFT)100 = 40.51% TOTAL PV AREA POPULATES 40.51% OF TOTAL PLAN VIEW AREA AND IS NOT WITHIN THE 33% REQUIREMENT. FIRE SETBACK ROOF LADDER ACCESS POINT Roof Azimuth: 70 ° Roof Tilt: 20 ° Roof Section 2CBUMMSPACD1ACD2 (E) UNPERMITED SHED (NO ELECTRICAL)54 CLEMENT STRoof Azimuth: 250 ° Roof Tilt: 20 ° Roof Section 3 N 3'3' 3'3' 3' 3' 266'-4" SCALE: 3/32" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 14.82 kW DC LEGEND CONSTRUCTION NOTES PV INTERCONNECTION POINT. LOCATION OF MAIN SERVICE PANEL & AC DISCONNECT 2 MOUNTED ON INTERIOR WALL & UTILITY METER, AC DISCONNECT 1 & COMBINER BOX MOUNTED ON EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE. NEW SOLAR PANELS (39) SOLARIA POWER X-380R-2B (380W) [BLK] WITH AN ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS MOUNTED TO THE BACK OF EVERY MODULES MOUNTED ON COMP SHINGLE ROOF SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR PV-1.1 SITE PLAN LAYOUT LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 ROOF OBSTRUCTIONS JB (N)CONDUIT RUN CB COMBINER BOX Roof Azimuth: 70° Roof Tilt: 20° Roof Section 1 ACD AC DISCONNECT MSP MAIN SERVICE PANEL UM UTILITY METER 1.SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2.THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE IBC SECTION 1609 TO WITHSTAND A BASIC WIND EXPOSURE B. 3. THE ROOF MEMBERS ARE 2"X 6" TRUSSES AT 16" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4.THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5.ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6.ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (IRC R324.6, IBC 3111.3.4) 6.1.LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2.LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. 7.SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN COMPLIANCE WITH IBC/ IFC 1205.2.1.2 TOTAL PLAN VIEW AREA = 2026.2 SQFT TOTAL PV AREA = 39(67.8 IN)(44.7 IN)/(144 IN^2) = 820.80 SQFT (820.80 SQFT/ 2026.2 SQFT)100 = 40.51% TOTAL PV AREA POPULATES 40.51% OF TOTAL PLAN VIEW AREA AND IS NOT WITHIN THE 33% REQUIREMENT. PRO P E R T Y LI N E FIRE SETBACK ROOF LADDER ACCESS POINT Roof Azimuth: 70 ° Roof Tilt: 20 ° Roof Section 2WALKWAY ROOF LADDER ACCESS POINTCBUM MSP ACD1ACD2 (E) UNPERMITED SHED (NO ELECTRICAL)54 CLEMENT STROOF LADDER ACCESS POINT Roof Azimuth: 250 ° Roof Tilt: 20 ° Roof Section 3 ROOF LADDER ACCESS POINT ROOF LADDER ACCESS POINT 4'4'4'4'4' 4'4'4' 4'4'4' 4'4'4'4'4'4'4'4'4'4'4'NNNSCALE: 1/8" = 1'-0" PV SYSTEM MOUNTING DETAILSPROPOSED UNIRAC SOLARMOUNT RACKING EXISTING 2"X 6" ROOF TRUSSES @ 16"O.C SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR PV-2 ATTACHMENT DETAILS PROPOSED SOLARIA POWER X-380R-2B (380W) [BLK] PV SOLAR MODULES Roof Azimuth: 70° Roof Tilt: 20° Roof Section 1 EXISTING COMP SHINGLE ROOF UNIRAC FLASHLOC FOR COMP SHINGLE @ 48" O.C. MAX Roof Azimuth: 70 ° Roof Tilt: 20 ° Roof Section 2 Roof Azimuth: 250 ° Roof Tilt: 20 ° Roof Section 3 ROOF SLOPE910 10 6 21 7 S-5 D5 20 11 121413151822 S-5 D4 3 1 54 252423 8 26 2 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR 1.ROOF MATERIAL: COMP SHINGLE 2.ROOF STRUCTURE: TRUSSES 3.ATTACHMENT TYPE: UNIRAC FLASHLOC 4.MODULE MANUFACTURER: SOLARIA 5.MODULE MODEL: POWER X-380R-2B (380W) [BLK] 6.MODULE LENGTH: 67.8'' 7.MODULE WIDTH: 44.7" 8.MODULE WEIGHT: 48.7 LBS. 9.SEE SHEET S-1 FOR DIMENSION(S) 10.MIN. FIRE OFFSET 11.TRUSSES SPACING: 16" O.C. 12.TRUSSES SIZE: 2"X 6" NOMINAL 13.LAG BOLT DIAMETER: 5/16 IN. 14.LAG BOLT EMBEDMENT: 2.5 IN. 15.TOTAL # OF ATTACHMENTS: 94 16.TOTAL AREA: 820.80 SQ. FT. 17.TOTAL WEIGHT: 1899.30 LBS. 18.WEIGHT PER ATTACHMENT: 20.21 LBS. 19.DISTRIBUTED LOAD: 2.31 PSF 20.MAX. HORIZONTAL STANDOFF: 48 IN. 21.MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 43 IN. 22.STANDOFF STAGGERING: YES 23.RAIL MANUFACTURER AND MODEL (OR EQUIV.):UNIRAC SOLARMOUNT 24.RAIL WEIGHT: 0.436 PLF. 25.MAX. TRUSSES SPAN: 12 FT. 26.MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. PV-3 MOUNTING DETAILS 3 M POINT OF DELIVERY AND INTERCONNECTION 200A N (E) GROUNDING ELECTRODE OR (UFER) 60A (N) 60A FUSED AC DISCONNECT 2 SUPPLY-SIDE SOLAR TAP NEC 705.11 EXISTING 240V/200A MAIN SERVICE PANEL SINGLE PHASE EXISTING WIRE (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT 1 3 AC DISCONNECT TO BE LOCATED WITHIN 10' OF METER 3 13 PV CIRCUIT 1: 13 MODULES/PARALLEL ROOF TOPGROUND LEVEL -HOUSE EXTER IOR 13 PV CIRCUIT 2: 13 MODULES/PARALLEL 12 12 13 PV CIRCUIT 3: 13 MODULES/PARALLEL 12 1 1 1 (N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE 2 20A 20A N 15A 20A (N) 39 SOLARIA POWER X-380R-2B (380W) [BLK] MODULES WITH AN ENPHASE IQ8PLUS-72-2-US MICRO-INVERTER ATTACHED TO THE BACK OF EVERY MODULE. (N) 125A/240V AC COMBINER BOX WITH ENPHASE IQ ENVOY COMM. GATEWAY ENPHASE IQENVOYCOMMUNICATIONSGATEWAYNOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH END OF THE EMT CONDUIT WITH THE WIRE THEN FREE AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL 2A SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR E-1 ELECTRICAL DIAGRAM METER # 74567722 Inverter Ratings Inverter Make/Model ENPHASE IQ8PLUS-72-2-US Max DC Volt Rating 60V Max. Continous Output Power 290W Max Nominal Voltage 240V Max Continuous Output Current 1.21A Max OCPD Rating 20A DESIGN TEMPERATURES ASHRAE EXTREME LOW -17°C ASHRAE 2% HIGH 32°C PV Module Ratings @ STC Module Make/Model SOLARIA POWER X-380R-2B (380W) [BLK] Max Power-Point Current (Imp)12.44A Max Power-Point Voltage (Vmp)30.59V Open-Circuit Voltage (Voc)36.45V Short-Circuit Current (Isc)13.34A Max Series Fuse (OCPD)25A Nominal Maximum Power at STC (Pmax)380W Maximum System Voltage 1000V Voc Temperature Coefficient -0.28%/°C Conduit and Conductor Schedule Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 Enphase Q cable - THWN-2 10 AWG 3 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 10 AWG 6 EMT 3/4" 2 THWN-2 - Ground 10 AWG 1 EMT 3/4" 2A THWN-2 10 AWG 3 N/A - Free Air N/A - Free Air 3 THWN-2 6 AWG 3 EMT 3/4" 3 THWN-2 - Ground 6 AWG 1 EMT 3/4" MAIN SERVICE PANEL SUPPLY SIDE TAP NEC 705. 11 SUPPLY SIDE. POWER PRODUCTION SOURCES SYSTEM SUMMARY BRANCH #1 BRANCH #2 BRANCH #3 INVERTERS PER BRANCH 13 13 13 MAX CONTINUOUS OUTPUT CURRENT 15.73A 15.73A 15.73A MAX CONTINUOUS OUTPUT POWER 3770W 3770W 3770W ARRAY STC POWER 14820W ARRAY PTC POWER 13607.1W MAX CONTINUOUS OUTPUT CURRENT 47.19A MAX CONTINUOUS OUTPUT POWER 11310W DERATED (CEC) AC POWER 13198.89W N1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE 3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: (N) SOLAR PANELS AND MICRO-INVERTERS ON ROOF MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 47.19 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC2020 : 690.54 SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR E-2 WARNING LABELS WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. PV INTERCONNECTION POINT. LOCATION OF MAIN SERVICE PANEL, UTILITY METER, TWO AC DISCONNECTS & COMBINER BOX. ELECTRICAL SHOCK HAZARD WARNING! TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): NEC2020 : 690.13(B) & 706.15(C)(4) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC2020 : 690.56(c)(2) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER AND ESS OCPD (IF APPLICABLE). PER CODE(S): NEC2020 : 705.12(B)(3)(2), SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC2020 : 690.56(C), NEC 2017: 690.56(C)(1)(a) LABEL LOCATION: MAIN SERVICE PANEL (IF APPLICABLE). PER CODE(S): NEC2020 : 705.12(B)(3)(3) LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS 54 CLEMENT ST SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR S-1 SPEC SHEET SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR S-2 SPEC SHEET SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR S-3 SPEC SHEET SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR S-4 SPEC SHEET SHEET PAUL ST LAURENCE JR RESIDENCE 54 CLEMENT ST, FLORENCE, MA 01062 APN:3719522 DATE:8/31/2023 3000 EXECUTIVE PKWY, STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 DESIGNER: OSR S-5 SPEC SHEET