Loading...
Smith, Scott Planset 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com July 6, 2023 Current Insight 2852 W. Amini Way South Jordan, UT 84095 Re: Engineering Services Smith Residence 62 West Parsons Lane, Northampton MA 5.840 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed s ystem including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x8 dimensional lumber at 16” on center. Roof Material: Composite Asphalt Shingles Roof Slope: 22 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 IRC, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non - uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE MA License No. 50507 Massachusetts COA # 1629764 GENERAL NOTES1.1.1PROJECT NOTES:1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICCODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATIONINSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITYHAVING JURISDICTION’S (AHJ) APPLICABLE CODES.1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEMINSPECTED PRIOR TO PARALLEL OPERATION1.1.4 GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATEDWITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B)1.1.5 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, ANDSOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE INPHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4:PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIREINVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY1.1.6 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMPCOEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATEDACCORDING TO NEC 690.7.1.1.7 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCECIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILLBE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BEINSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC110.3].1.1.8 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IFEXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGEWILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.1.2.1 SCOPE OF WORK:1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OFTHE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BERESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN,SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT.1.3.1 WORK INCLUDES:1.3.2 PV ROOF ATTACHMENTS - IRONRIDGE FLASH VUE1.3.3 PV RACKING SYSTEM INSTALLATION - IRONRIDGE AIRE RAIL A11.3.4 PV MODULE AND INVERTER INSTALLATION - REC SOLAR REC365NP2 BLK / ENPHASEIQ8PLUS-72-2-US1.3.5 PV EQUIPMENT GROUNDING1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED SOLADECK JUNCTION BOX1.3.7 PV LOAD CENTERS (IF INCLUDED)1.3.8 PV METERING/MONITORING (IF INCLUDED)1.3.9 PV DISCONNECTS1.3.10 PV GROUNDING ELECTRODE & BONDING TO (E) GEC1.3.11 PV FINAL COMMISSIONING1.3.12 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV1.3.13 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE*NEC2020MSCOPE OF WORKSYSTEM SIZE: STC:16 X 365W+ 22X365W = 13.870KWPTC:16 X 343.7W+22X343.7W = 13.060KW(N) (16)REC SOLAR REC365NP2 BLK(E) (22) REC SOLAR REC365NP2 BLK(N) (16) ENPHASE IQ8PLUS-72-2-US(E) (22) ENPHASE IQ8PLUS-72-2-USATTACHMENT TYPE: IRONRIDGE FLASH VUEPROJECT INFORMATION:SERVICE PHASE: SINGLESERVICE SIZE (AMPS): 200ACONNECTIVITY TYPE: OVERHEADUTILITY METER NUMBER: #72026453SCOPE OF WORK:INVERTER: (16) ENPHASE IQ8PLUS-72-2-USPANELS:(16) REC SOLAR REC365NP2 BLACKDC-STC RATING OF SYSTEM: 5.840 KWPAC SYSTEM DESIGN CAPACITY (NOMINAL): 4.640 KWPAC SYSTEM DESIGN CAPACITY (MAXIMUM): 4.800 KWP62 W PARSONS LN.,NORTHAMPTON, MA 01062ASSESSOR'S #: 35 -262-001SCOTT SMITH RESIDENCENEW PV SYSTEM: DC 5.840 kWPEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPOWNERNAME: SCOTT SMITHPROJECT MANAGERNAME: PATRICK RONDEAUPHONE: 413-588-8185CONTRACTORNAME: VALLEY SOLAR LLCPHONE: 413-584-8844AUTHORITIES HAVING JURISDICTIONBUILDING: CITY OF NORTHAMPTONZONING: CITY OF NORTHAMPTONUTILITY: NATIONAL GRIDDESIGN SPECIFICATIONSRISK CATEGORY: IICONSTRUCTION: SINGLE-FAMILYZONING: RESIDENTIAL GRID-TIEDGROUND SNOW LOAD: 40 PSFWIND EXPOSURE: CWIND SPEED: 117 MPHAPPLICABLE CODES & STANDARDSBUILDING: MASSACHUSETTS BUILDING CODE,9TH EDITION, AS AMENDED (780 CMR)MASSACHUSETTS RESIDENTIONAL BUILDING CODE,9TH EDITION, AS AMENDED (780 CMR)ELECTRICAL: NEC 2023FIRE: MASSACHUSETTS COMPREHENSIVE FIRE SAFETY CODE(527 CMR 1.00); NFPA 1 FIRE CODE - 2021PROJECT INFORMATIONBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPT-001.00COVER PAGE(SHEET 1)PLAT MAP02SCALE: NOT TO SCALEAERIAL PHOTO01SCALE: NOT TO SCALENEWSSHEET LIST TABLESHEET NUMBERSHEET TITLET-001COVER PAGEG-001NOTESA-101SITE PLANA-102ELECTRICAL PLANA-103SOLAR ATTACHMENT PLANA-104ROOF PLANE-601LINE DIAGRAME-602DESIGN TABLESE-603PLACARDSS-501ASSEMBLY DETAILSR-001RESOURCE DOCUMENTR-002RESOURCE DOCUMENTR-003RESOURCE DOCUMENTR-004RESOURCE DOCUMENTR-005RESOURCE DOCUMENTR-006RESOURCE DOCUMENTW PARSONS LN.Signed 7/06/2023 2.1.1SITE NOTES:2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITYINTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDINGROOF VENTS.2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICALEQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26.2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITHTHIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOFCOVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE.2.2.1EQUIPMENT LOCATIONS:2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26.2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATINGTEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLE 310.15 (B)(1).2.2.4 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC690.34.2.2.5 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHINSIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TONEC APPLICABLE CODES.2.2.7 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHENAPPROPRIATE.2.3.1STRUCTURAL NOTES:2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANTINSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THEARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS.2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IFROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS.2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVEDCHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR.2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCESPECIFIED BY THE RACKING MANUFACTURER.2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGSTTHE ROOF FRAMING MEMBERS.2.4.1WIRING & CONDUIT NOTES:2.4.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT ANDWIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANTTO LIMIT UP-SIZING.2.4.3 CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.2.4.4 VOLTAGE DROP LIMITED TO 1.5%.2.4.5 DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BELOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS.2.4.6 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS:PHASE A OR L1- BLACKPHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASEPHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTIONNEUTRAL- WHITE OR GRAYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKEDORANGE [NEC 110.15].2.5.1GROUNDING NOTES:2.5.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDINGDEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE.2.5.3 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE250.122.2.5.4 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDEREDGROUNDED IN ACCORD WITH 250.134 AND 250.136(A).2.5.5 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 ANDMICROINVERTER MANUFACTURERS' INSTRUCTIONS.2.5.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLESPER THE MANUFACTURERS' INSTALLATION REQUIREMENTS.2.5.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVALOF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE.2.5.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN ORMARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]2.5.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODESYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ.2.5.10 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) THROUGH (3) TO REDUCEFIRE HAZARDS2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THECONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINESIDE” (TYPICALLY THE UPPER TERMINALS).2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE AVISIBLE-BREAK SWITCH2.6.4 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWNFUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH690.12(A) THROUGH (D).2.6.5 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240.2.6.6 MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES INACCORDANCE WITH NEC 110.3(B).2.6.7 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TONEC 690.11 AND UL1699B.2.7.1INTERCONNECTION NOTES:2.7.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH NEC 705.122.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THERATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BELOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(3)(2)].2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALLOVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THECOMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(3)(3).2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (B)(1) AND (2)2.7.6 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.11 WITH SERVICE ENTRANCECONDUCTORS IN ACCORDANCE WITH NEC 230.422.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROMADDITIONAL FASTENING [NEC 705.12 (E)].*NEC2020M *NEC2020M BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPG-001.00NOTES(SHEET 2)Signed 7/06/2023 GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGEPROPERTY LINEBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPA-101.00(SHEET 3)01/32" = 1'-0"SITE PLAN0116' 32'NEWSAREA OF WORKSITE PLANENTRANCEUTILITY METERW PARSONS LN.AC DISCONNECT36'-9"43'-3"74'-5"109'-5"Signed 7/06/2023 MODULE STRINGINGABMODULE STRINGINGFIRE CLEARANCETOTAL ROOF AREA: 1833.64 SQ. FTNEW SOLAR PANELS AREA: 311.72 SQ. FTPERCENTAGE OF ROOF COVERED BY THE NEW ARRAY: 17%EXISTING SOLAR PANELS AREA: 428.61 SQ. FTPERCENTAGE OF ROOF COVERED BY THE EXISTING ARRAY: 23.4%TOTAL PERCENTAGE OF ROOF COVERED BY THE ARRAYS: 40.4%GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGE40.6"69.1"MODULE:REC SOLARREC365NP2 BLK365 WATTS40.6"69.1"MODULE:REC SOLARREC365NP2 BLK365 WATTSBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPA-102.00(SHEET 4)01/8" = 1'-0"ELECTRICAL PLAN014' 8'NEWSELECTRICAL PLANEXTERIOR PV EQUIPMENT(E) (1) UTILITY METERINTERIOR PV EQUIPMENT(E) (1) MAIN ELECTRICAL PANEL(E) (1) AC COMBINER BOX(E) (1) AC DISCONNECT(N) (1) BREAKER BOX3 FT. FIRE ACCESS PATH3 FT. FIRE ACCESS PATH3 FT. FIRE ACCESS PATH3 FT. FIRE ACCESS PATHAAAAAAAAABBBBBBBARRAY 1 - 5.840 kW[x16] (N) MODULESTILT: 22 DEGREESROOF PITCH: 5:12AZIMUTH: 90 DEGREES(E) PV ARRAY 40.6"69.1"MODULE:REC SOLARREC365NP2 BLK365 WATTSROOF RAFTERSGENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGE40.6"69.1"MODULE:REC SOLARREC365NP2 BLK365 WATTSBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPA-103.00(SHEET 5)01/8" = 1'-0"SOLAR ATTACHMENT PLAN014' 8'SOLAR ATTACHMENT PLANNEWSROOF MATERIAL IS ASPHALT SHINGLEFLUSH MOUNT SOLAR MODULESATTACHED TO ROOF SURFACE (SEESHEET S-501 FOR MOUNTING DETAILS)13'-8"17'-1"Signed 7/06/2023 GENERAL NOTES1. FIELD VERIFY ALL MEASUREMENTS2. ITEMS BELOW MAY NOT BE ON THIS PAGEBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPA-104.00(SHEET 6)ROOF PLAN01SCALE: NOT TO SCALEROOF PLANSigned 7/06/2023 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONSID TYPICALCONDUCTORCONDUITCURRENT-CARRYINGCONDUCTORS IN CONDUITOCPDEGCTEMP. CORR.FACTORCONDUIT FILLFACTORCONT.CURRENTMAX. CURRENT(125%)BASE AMP.DERATEDAMP.TERM. TEMP. RATINGAMP. @ TERMINAL1 110 AWG THWN-2, COPPER0.75'' DIA EMT820A10 AWG THWN-2, COPPER0.96 (32.7 °C)0.713.31A 16.64A40A 26.88A75°C35A2 16 AWG THWN-2, COPPER0.75'' DIA EMT2N/A10 AWG THWN-2, COPPER0.96 (32.7 °C)145.98A 57.48A75A72A75°C65A3 16 AWG THWN-2, COPPER0.75'' DIA EMT260A10 AWG THWN-2, COPPER0.96 (32.7 °C)145.98A 57.48A75A72A75°C65A4 16 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.7 °C)145.98A 57.48A75A72A75°C65ANEW PV SYSTEM 5.840KW EXIST. PV SYSTEM 8.030KW TOTAL PV SYSTEM 13.870KWMODULE STRINGINGAMODULE STRINGINGBNG(E)MAIN200A(E)UTILITYMETER# 072026453L1L2TAPNL2NL1TO UTILITYGRID (OH)(E) GROUNDINGELECTRODEGROUNDRODTO (E)LOADSL1 N L2GENPHASE ENVOYCOMMUNICATIONSGATEWAYETHERNET CABLETO BROADBANDROUTERCB120ACB220AEx20AEx20AEx15A(E) 125A AC LOAD CENTERENPHASE IQ COMBINER 4120/240V, 1Ø, 3WMAX. CONTINUOUS CURRENT: 65AMAX. OCPD: 90AREDBLACK(E) (22) REC SOLARREC365NP2 BLK365W(E) (22) ENPHASEIQ8PLUS-72-2-USMICROINVERTERPV SYSTEM EQUIPPED WITH RAPIDSHUTDOWN DISCONNECT PER NEC 690.12SYSTEM COMPLIANT WITH NEC 690.13IN BRANCHA9SOLADECK JUNCTION BOX2G(E) AC DISCONNECT 60A1READILY ACCESSIBLE OPEN BLADE AC SYSTEMDISCONNECT VISIBLE FROM APPROACH TORESIDENCE 60A 240V LOCATED EXTERIOR ON WALLNEAR METER NEMA 3RREDBLACK(E) MAIN ELECTRICAL PANEL240/120V, 1Ø, 3WMAIN BUSS: 200AIN BRANCHB7REDBLACKREDBLACKIN BRANCHEx11IN BRANCHEx11GCB360A/2P43(N) (16) REC SOLARREC365NP2 BLK365W(N) (16) ENPHASEIQ8PLUS-72-2-USMICROINVERTER(N) 70А BREAKER BOXCOMPLIES WITH NEC 240.21BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPE-601.00(SHEET 7)LINE DIAGRAM BILL OF MATERIALSCATEGORYMAKEMODEL NUMBERREFQTYUNITQTY/UNITDESCRIPTIONMODULEREC SOLARREC365NP2 BLKPM1-3838PIECES1REC SOLAR REC365NP2 BLK 365W 72 CELLS, MONOCRYSTALLINE SILICONINVERTERENPHASEIQ8PLUS-72-2-USI1-3838PIECES1ENPHASE IQ8PLUS-72-2-US 290W INVERTERMISC ELECTRICAL EQUIPMENTGEN-CABLE-CLIPHDWR41-231190PIECES1GENERIC CABLE CLIPWIRINGENPHASEQ-12-17-240EN1-3838PIECES1ENPHASE ENGAGE (TM) TRUNK CABLEWIRINGENPHASEQ-TERM-10EN391BUNDLE10ENPHASE ENGAGE (TM) BRANCH TERMINATORWIRINGENPHASEQ-SEAL-10EN401BUNDLE10ENPHASE ENGAGE (TM) WATERTIGHT SEALING CAPWIRINGGEN-10-AWG-THWN-2-CU-RDWR1180FEET110 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-10-AWG-THWN-2-CU-BLKWR1180FEET110 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-10-AWG-THWN-2-CU-GRWR1-365FEET110 AWG THWN-2, COPPER, GREEN (GROUND)WIRINGGEN-6-AWG-THWN-2-CU-RDWR2-430FEET16 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-6-AWG-THWN-2-CU-BLKWR2-430FEET16 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-6-AWG-THWN-2-CU-WHWR2-430FEET16 AWG THWN-2, COPPER, WHITE (NEUTRAL)WIRINGGEN-6-AWG-THWN-2-CU-GRWR410FEET16 AWG THWN-2, COPPER, GREEN (GROUND)WIREWAYENPHASEET-SPLK-05EN71BUNDLE5ENPHASE ENGAGE (TM) ENGAGE COUPLERWIREWAYGEN-EMT-0.75'' DIAWW1-475FEET1EMT CONDUIT, 0.75'' DIAOCPDGENERIC MANUFACTURERGEN-CB-20A-240VACCB1-22PIECES1CIRCUIT BREAKER, 20A, 240VACOCPDGENERIC MANUFACTURERGEN-CB-60A-240VACCB31PIECE1CIRCUIT BREAKER, 60A, 240VACTRANSITION BOXGENERIC MANUFACTURERGEN-AWB-TB-4-4XJB11PIECE1TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKSSYSTEM SUMMARY(E) BRANCH #1(E) BRANCH #2(N) BRANCH #3(N) BRANCH #4INVERTERS PER BRANCH111188MAX AC CURRENT13.31A13.31A9.68A9.68AMAX AC OUTPUT POWER3,190W3,190W2,320W2,320WARRAY STC POWER13,870WARRAY PTC POWER12,991WMAX AC CURRENT45.98AMAX AC POWER11,020WDERATED (CEC) AC POWER11,020WINVERTERSOCPDSMODULESASHRAE EXTREME LOW-25.9°C (-14.6°F), SOURCE: BARNES MUNI (42.16°; -72.72°)ASHRAE 2% HIGH32.7°C (90.9°F), SOURCE: BARNES MUNI (42.16°; -72.72°)REF.QTY.RATED CURRENTMAX VOLTAGECB1-2220A240VACCB3160A240VACREF.QTY.MAKE AND MODELPMAXPTCISCIMPVOCVMPTEMP. COEFF. OF VOCFUSE RATINGPM1-1616REC SOLAR REC365NP2 BLK365W341.88W11.36A10.65A40.9V34.3V-0.106V/°C (-0.26%/°C)25AREF.QTY.MAKE AND MODELACVOLTAGEGROUNDOCPDRATINGRATEDPOWERMAX OUTPUTCURRENTMAX INPUTCURRENTMAX INPUTVOLTAGECEC WEIGHTEDEFFICIENCYI1-1616ENPHASE IQ8PLUS-72-2-US240VFLOATING20A290W1.21A20A60V97.0%BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPE-602.00(SHEET 8)DESIGN TABLES BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPE-603.00(SHEET 9)PLACARDS!CAUTION!POWER TO THIS BUILDING IS ALSO SUPPLIED FROMROOF MOUNTED SOLAR ARRAYS WITH SAFETYDISCONNECTS AS SHOWN:NEWSFRONTBACKPV ARRAYLABELING NOTES1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z5351.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED.1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND;“WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND.[ANSI Z535]LABEL 3AT POINT OF INTERCONNECTION, MARKEDAT DISCONNECTING MEANS (4" X 3").[NEC 690.54]LABEL 4AT EACH AC DISCONNECTING MEANS(4" X 1").[NEC 690.13(B)].PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICEDISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTINGMEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8").[NEC 690.56(B)]WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, ADIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PVSYSTEM DISCONNECTING MEANS.PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED INBATHROOMS[NEC 690.4(D),(E)]PHOTOVOLTAIC POWER SOURCELABEL 9AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRINGMETHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERESEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS,OR FLOORS (5 3/4" X 1 1/8").[NEC 690.31(G)]LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND;REFLECTIVE[IFC 605.11.1.1]SOLAR PV SYSTEMEQUIPPED WITHRAPID SHUTDOWNTURN RAPID SHUTDOWN SWITCH TOTHE "OFF" POSITION TO SHUT DOWNPV SYSTEM AND REDUCE SHOCKHAZARD IN ARRAYLABEL 6AT RAPID SHUTDOWN SYSTEM(3 3/4" X 5 1/4"). [NEC 690.56(C)(1)(A)].WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLARELECTRIC SYSTEMLABEL 7AT POINT OF INTERCONNECTION(2 3/4" X 1 5/8").[NEC 705.12(B)(3)]WARNINGSOLAR ELECTRICCIRCUIT BREAKERIS BACKFEDLABEL 8AT POINT OF INTERCONNECTION(2" X 1").[NEC 705.12(B)(3)]CAUTIONSOLAR ELECTRIC SYSTEM CONNECTEDLABEL 10AT UTILITY METER (5 3/4" X 1 1/8")[NEC 690.56(B)]RAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL 5AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2").[NEC 690.56(C)(3)].AC DISCONNECTPHOTOVOLTAIC SYSTEMPOWER SOURCERATED ACOUTPUT CURRENTNOMINAL OPERATINGAC VOLTAGEAMPSVOLTSPHOTOVOLTAIC SYSTEMDISCONNECTELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL 1AT EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT (2" X 4").[NEC 690.13].POWER SOURCEOUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNINGLABEL 2AT POINT OF INTERCONNECTIONOVERCURRENT DEVICE (2" X 4").[NEC 705.12(B)(2)(3)(B)].INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTEDPHOTOVOLTAIC SYSTEM DISCONNECT LOCATEDSOUTH SIDE OF THE HOUSE45.98240SOLAR ELECTRICPV PANELSDIRECTORYPV ARRAYEXTERIOR PV EQUIPMENT(E) (1) UTILITY METERINTERIOR PV EQUIPMENT(E) (1) MAIN ELECTRICAL PANEL(E) (1) AC COMBINER BOX(E) (1) AC DISCONNECT(N) (1) BREAKER BOX 2011121413151822S-501D523154827S-501D4242325SHEET KEYNOTES1.ROOF MATERIAL: ASPHALT SHINGLE 2.ROOF STRUCTURE: COLAR TIE3.ATTACHMENT TYPE: IRONRIDGE FLASH VUE4.MODULE MANUFACTURER: REC SOLAR 5.MODULE MODEL: REC365NP2 BLK 6.MODULE LENGTH: 69.1 IN. 7.MODULE WIDTH: 40.6 IN. 8.MODULE WEIGHT: 44.1 LBS. 9.SEE SHEET A-103 FOR DIMENSION(S)10.MIN. FIRE OFFSET: 36" FROM RIDGE, 36" FROM EDGE11.RAFTER SPACING: 16 IN. O.C. 12.RAFTER SIZE: 2X8 IN. 13.LAG BOLT DIAMETER: BOLT/SCREW SUPPLIED WITH RACKING14.LAG BOLT EMBEDMENT: 2.5 IN.15.TOTAL # OF ATTACHMENTS: 3616.TOTAL AREA: 311.72 SQ. FT.17.TOTAL WEIGHT: 790.88 LBS.18.WEIGHT PER ATTACHMENT: 21.97 LBS.19.DISTRIBUTED LOAD: 2.54 PSF.20.MAX. HORIZONTAL STANDOFF: 48 IN. 21.MAX. VERTICAL STANDOFF: IN ACCORDANCE WITH MODULEMANUFACTURER'S INSTRUCTIONS22.STANDOFF STAGGERING: YES23.RAIL MANUFACTURER (OR EQUIV.): IRONRIDGE24.RAIL MODEL (OR EQUIVALENT): AIRE RAIL A125.RAIL WEIGHT: 0.436 PLF.26.MAX. RAFTER SPAN: N/A27.MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX1.FIELD VERIFY ALL MEASUREMENTSGENERAL NOTESROOF SLOPE 910106217BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWP(SHEET 10)ASSEMBLY DETAILSD4DETAIL (TRANSVERSE)NOT TO SCALED5DETAIL (LONGITUDINAL)NOT TO SCALED1RACKING DETAIL (TRANSVERSE)NOT TO SCALED3RACKING DETAIL (TOP)NOT TO SCALED2RACKING DETAIL (LONGITUDINAL)NOT TO SCALES-501.00Signed 7/06/2023 BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPR-001.00(SHEET 11)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPR-002.00(SHEET 12)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPR-003.00(SHEET 13)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPR-004.00(SHEET 14)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPR-005.00(SHEET 15)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: DC 5.840 kWPENGINEER OF RECORDDESIGN BY:PAPER SIZE: 11" x 17" (ANSI B)ACDEGHBCFGH1456CONTRACTORPHONE:LIC. NO.:DATE:CHECKED BY:HIC. NO.:ELE. NO.:ADDRESS:VALLEY SOLAR LLC116 PLEASANT ST STE 321EASTHAMPTON, MA 0102762 W PARSONS LN.,NORTHAMPTON, MA 01062APN: 35 -262-001SCOTT SMITHRESIDENCE 186338664A1413-584-8844A.L.M.M.06.04.2023REVISIONSEXISTING PV SYSTEM: DC 8.030 kWPTOTAL PV SYSTEM: DC 13.870 kWPR-006.00(SHEET 16)RESOURCE DOCUMENT