107 Franklin St - Beam CalcsBase Cascade Triple 1-3/4" x 9-1/2" VERSA -LAM® LVL 2.1E 3100 SP [PASSED 1st Floor Deck - Basement Walls\Dropped Beams\DB1-3(i319) (Dropped Beam) BC Design Engine Member Report Dry 12 spans I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St 1 Description: 1st Floor Deck - Baseme... loped Beams\DB1-3(i319) City, State, Zip: Northampton , Ma ` Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles B 1 ' 0-05-0A B2 09-06-08 B3 Total Horizontal Product Length = 20-00-00 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1. 5-1/2" 2292 / 261 617 / 0 B2. 8" 6096 / 0 1696 / 0 B3, 2-1/2" 2077 / 340 486 / 0 Load Summary Live Dead Snow Wind Roof Tributary Tag Description Load Type Ref. Start End Loc. 100% 90% Live 115% 160% 125% 0 Self -Weight Unf. Lin. (lb/ft) L 00-00-00 20-00-00 Top 14 00-00-00 1 Smoothed Load Unf. Lin. (lb/ft) L 01-03-00 19-09-08 Top 508 127 n\a 2 Rim 1(i395) Conc. Pt. (Ibs) L 00-05-08 00-05-08 Top 440 158 n\a Controls Summary Value %Allowable Duration Case Location Pos. Moment 5949 ft-Ibs 28.7% 100% 2 04-07-00 Neg. Moment -7445 ft-Ibs 67.5% 100% 1 10-05-08 End Shear 2355 Ibs 24.9% 100% 3 19-00-00 Cont. Shear 3439 Ibs 36.3% 100% 1 09-04-00 Total Load Deflection L/866 (0.139") 27.7% n\a 2 05-02-04 Live Load Deflection L/999 (0.117") n\a n\a 5 05-02-04 Total Neg. Defl. L/999 (-0.027") n\a n\a 2 13-05-14 Max Defl. 0.139" n\a n\a 2 05-02-04 Span / Depth 12.7 Bearing Supports Dim. (LxW) Value % Allow % Allow Support Member Material B1 Wall/Plate 5-1/2" x 5-1/4" 2908 Ibs 1.4% 13.4% Unspecified B2 Column 8" x 5-1/4" 7792 Ibs 2.7% 24.7% Unspecified B3 Wall/Plate 2-1/2" x 5-1/4" 2563 Ibs 2.8% 26.0% Unspecified Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. Calculations assume unbraced length of Top: 01-01-12, Bottom: 19-04-00 Page 14 of 15 so secascede Triple 1-3/4" x 9-1/2" VERSA -LAM® LVL 2.1E 3100 SP PASSED 1st Floor Deck - Basement Walls\Dropped Beams\DB1-3(i319) (Dropped Beam) BC Design Engine Member Report Dry 12 spans I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 1st Floor Deck - Baseme... pped Beams\DB1-3(i319) City. State, Zip: Northampton , Ma Specifier: Customer: 1) Designer: DH Code reports: ESR-1040 Company: rk Miles Connection Diagram: Full Length of Member b 4 — d a c e o 0 0 a minimum = 2" c = 4-1/2" b minimum = 3" d = 24" e minimum = 3" Calculated Side Load = 0.0 Ib/ft Nailing applies to both sides of the member Connectors are: 3-1/4 in. Pneumatic Gun Nails Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM, ALLJOIST®, BC RIM BOARD TM", BCI® , BOISE GLULAMT'", BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 15 of 15 2nd Floor Deck - 1st Floor Walls\Flush Beams\FB1-3 i BasecawacW Triple 1-3/4" x 14" VERSA -LAM® 2.0 3100 SP PASSED ( 308) (Flush Beam) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1 st Flo...\Flush Beams\FB1-3(i308) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles B1 20-04-00 B2 Total Horizontal Product Length = 20-04-00 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1.. 5-1/2" 4394 / 0 3624 / 0 2123 / 0 B2. 4" 3388 / 0 1347 / 0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100 % 90 % 115 % 160 % 125% 0 Self -Weight Unf. Lin. (lb/ft) L 00-00-00 20-04-00 Top 21 00-00-00 1 BM1-2(i415) Conc. Pt. (Ibs) L 00-01-12 00-01-12 Back 924 2112 1983 n\a 2 E9(i115) Conc. Pt. (Ibs) L 00-02-12 00-02-12 Top 101 140 n\a 3 Rim1(i382) Conc. Pt. (Ibs) L 00-05-08 00-05-08 Front 108 52 n\a 4 Rim 1(i384) Conc. Pt. (Ibs) L 00-05-08 00-05-08 Back 128 61 n\a 5 J12(i399) Conc. Pt. (Ibs) L 01-09-08 01-09-08 Front 216 72 n\a 6 J14(i403) Conc. Pt. (Ibs) L 01-09-08 01-09-08 Back 257 86 n\a 7 J12(i377) Conc. Pt. (Ibs) L 03-01-08 03-01-08 Front 216 72 n\a 8 J14(i378) Conc. Pt. (Ibs) L 03-01-08 03-01-08 Back 257 86 n\a 9 J12(i387) Conc. Pt. (Ibs) L 04-05-08 04-05-08 Front 216 72 n\a 10 J14(i376) Conc. Pt. (Ibs) L 04-05-08 04-05-08 Back 257 86 n\a 11 J12(i373) Conc. Pt. (Ibs) L 05-09-08 05-09-08 Front 216 72 n\a 12 J14(i402) Conc. Pt. (Ibs) L 05-09-08 05-09-08 Back 257 86 n\a 13 J12(i371) Conc. Pt. (Ibs) L 07-01-08 07-01-08 Front 216 72 n\a 14 J14(A14) Conc. Pt. (Ibs) L 07-01-08 07-01-08 Back 257 86 n\a 15 J12(i409) Conc. Pt. (Ibs) L 08-05-08 08-05-08 Front 216 72 n\a 16 J14(1370) Conc. Pt. (Ibs) L 08-05-08 08-05-08 Back 257 86 n\a 17 J12(i367) Conc. Pt. (Ibs) L 09-09-08 09-09-08 Front 216 72 n\a 18 J14(i368) Conc. Pt. (Ibs) L 09-09-08 09-09-08 Back 257 86 n\a 19 J12(i365) Conc. Pt. (Ibs) L 11-01-08 11-01-08 Front 216 72 n\a 20 J14(i406) Conc. Pt. (Ibs) L 11-01-08 11-01-08 Back 257 86 n\a 21 J12(i392) Conc. Pt. (Ibs) L 12-05-08 12-05-08 Front 216 72 n\a 22 J14(i364) Conc. Pt. (Ibs) L 12-05-08 12-05-08 Back 257 86 n\a 23 J12(i385) Conc. Pt. (Ibs) L 13-09-08 13-09-08 Front 216 72 n\a 24 J14(i362) Conc. Pt. (Ibs) L 13-09-08 13-09-08 Back 257 86 n\a 25 J12(i359) Conc. Pt. (Ibs) L 15-01-08 15-01-08 Front 216 72 n\a 26 J14(i360) Conc. Pt. (Ibs) L 15-01-08 15-01-08 Back 257 86 n\a 27 J12(i357) Conc. Pt. (Ibs) L 16-05-08 16-05-08 Front 216 72 n\a 28 J14(i398) Conc. Pt. (Ibs) L 16-05-08 16-05-08 Back 257 86 n\a 29 J12(i394) Conc. Pt. (Ibs) L 17-09-08 17-09-08 Front 216 72 n\a 30 J14(i356) Conc. Pt. (Ibs) L 17-09-08 17-09-08 Back 257 86 n\a 31 J12(i353) Conc. Pt. (Ibs) L 19-01-08 19-01-08 Front 216 72 n\a 32 J14(i354) Conc. Pt. (Ibs) L 19-01-08 19-01-08 Back 257 86 n\a Page 3 of 15 Boise �Triple 1-3/4" x 14" VERSA -LAM® 2.0 3100 SP PASSED' iYGIMf, tNFv Y.Y 3J VNf)1UC:.'. __. 2nd Floor Deck - 1st Floor Walls\Flush Beams\FB1-3(i308) (Flush Beam) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St I Description: 2nd Floor Deck - 1 st Flo ... \Flush Beams\FB1-3(i308) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles Controls Summary Value %Allowable Duration Case Location Pos. Moment 23893 ft-Ibs 54.9% 100% 1 09-09-08 End Shear 4545 Ibs 32.5% 100% 1 18-10-00 Total Load Deflection L/341 (0.692") 70.4% n\a 1 10-01-08 Live Load Deflection L/476 (0.496") 75.7% n\a 4 10-01-08 Max Defl. 0.692" n\a n\a 1 10-01-08 Span / Depth 16.9 % Allow °% Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 5-1/2" x 5-1/4" 8512 Ibs 4.2% 39.3% Unspecified B2 Wall/Plate 4" x 5-1/4" 4735 Ibs 3.2% 30.1% Unspecified Cautions Concentrated side load(s) 1,3,4,31,32 are closer than 18" from end of member. Please consult a technical representative or Professional of Record. Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. 1-3/4" x 14" VERSA-LAM(E) 2.0 3100 SP is a discontinued product. Discontinued products are not available for purchase. Calculations assume unbraced length of Top: 00-00-00, Bottom: 19-06-08. Connection Diagram: Full Length of Member C ° Disclosure e ° Use of the Boise Cascade Software is -- -- subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input a minimum = 2" c = 4-1/2" must be reviewed and verified by a b minimum = 3" d = 12" qualified engineer or other appropriate e minimum — 3" expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular Calculated Side Load = 343.0 Ib/ft application. The output here is based on Nailing applies to both sides of the member building code -accepted design Connectors are: 3-1/4 in. Pneumatic Gun Nails properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJST" ALLJOISTC . BC RIM BOARD T-, BCI aV , BOISE GLULAMT'^, BC FloorValue® , VERSA -LAW, VERSA -RIM PLUS®, Page 4 of 15 Boise cascw Triple 1-3/4" x 18" VERSA -LAM® 2.0 3100 SP LPASSED, Etim;tNEEHED'Nf/JD PROd1CTS 2nd Floor Deck - 1 st Floor Walls\Flush Beams\FB2-3(i249) (Flush Beam) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1 st Flo ... \Flush Beams\FB2-3(i249) City, State, Zip: Northampton , Ma Specifier: Customer: & Designer: DH Code reports: ESR-1040 Company: rk Miles B 1 20-05-08 62 Total Horizontal Product Length = 20-05-08 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1. 5-1 /2" 1518 / 0 4704 / 0 6064 / 0 3467 / 85 B2, 5-1 /2" 1483 / 0 4057 / 0 4630 / 0 2731 / 84 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self -Weight Unf. Lin. (Ib/ft) L 00-00-00 20-05-08 Top 27 00-00-00 1 E7(i111) Unf. Lin. (lb/ft) L 00-00-00 01-02-04 Top 636 1463 835 n\a 2 E7(i111) Unf. Lin. (lb/ft) L 00-00-00 2C-05-08 Top 74 n\a 3 E7(i111) Conc. Pt. (Ibs) L 00-00-04 00-00-04 Top 69 147 n\a 4 E7(i111) Conc. Pt. (Ibs) L 00-00-12 00-00-12 Top 3 11 12 n\a 5 E7(i111) Conc. Pt. (Ibs) L 00-00-12 00-00-12 Top -6 n\a 6 Rim1(i382) Conc. Pt. (Ibs) L 00-05-08 OC-05-08 Back 103 50 n\a 7 E7(i111) Conc. Pt. (Ibs) L 01-04-00 01-04-00 Top 6 22 24 n\a 8 E7(i111) Conc. Pt. (Ibs) L 01-04-00 01-04-00 Top -11 n\a 9 E7(i111) Unf. Lin. (Ib/ft) L 01-06-04 13-06-04 Top 258 450 257 n\a 10 J12(i399) Conc. Pt. (Ibs) L 01-09-08 01-09-08 Back 207 69 n\a 11 E7(i111) Conc. Pt. (Ibs) L 02-08-00 02-08-00 Top 6 22 24 n\a 12 E7(i111) Conc. Pt. (Ibs) L 02-08-00 02-08-00 Top -11 n\a 13 J12(i377) Conc. Pt. (Ibs) L 03-01-08 03-01-08 Back 207 69 n\a 14 E7(i111) Conc. Pt. (Ibs) L 04-00-00 04-00-00 Top 6 22 24 n\a 15 E7(i111) Conc. Pt. (Ibs) L 04-00-00 04-00-00 Top -11 n\a 16 J12(i387) Conc. Pt. (Ibs) L 04-05-08 04-05-08 Back 207 69 n\a 17 E7(i111) Conc. Pt. (Ibs) L 05-04-00 05-04-00 Top 6 22 24 n\a 18 E7(i111) Conc. Pt. (Ibs) L 05-04-00 05-04-00 Top -11 n\a 19 J12(i373) Conc. Pt. (Ibs) L 05-09-08 05-09-08 Back 207 69 n\a 20 E7(i111) Conc. Pt. (Ibs) L 06-08-00 06-08-00 Top 6 22 24 n\a 21 E7(i111) Conc. Pt. (Ibs) L 06-08-00 06-08-00 Top -11 n\a 22 J12(i371) Conc. Pt. (Ibs) L 07-01-08 07-01-08 Back 207 69 n\a 23 E7(i111) Conc. Pt. (Ibs) L 08-00-00 08-00-00 Top 6 22 24 n\a 24 E7(i111) Conc. Pt. (Ibs) L 08-00-00 08-00-00 Top -11 n\a 25 J12(i409) Conc. Pt. (Ibs) L 08-05-08 08-05-08 Back 207 69 n\a 26 E7(i111) Conc. Pt. (Ibs) L 09-04-00 09-04-00 Top 6 22 24 n\a 27 E7(i111) Conc. Pt. (Ibs) L 09-04-00 09-04-00 Top -11 n\a 28 J12(i367) Conc. Pt. (Ibs) L 09-09-08 09-09-08 Back 207 69 n\a 29 E7(i111) Conc. Pt. (Ibs) L 10-08-00 10-08-00 Top 6 22 24 n\a 30 E7(i111) Conc. Pt. (Ibs) L 10-08-00 10-08-00 Top -11 n\a 31 J12(1365) Conc. Pt. (Ibs) L 11-01-08 11-01-08 Back 207 69 n\a 32 E7(i111) Conc. Pt. (Ibs) L 12-00-00 12-00-00 Top 6 22 24 n\a Page 5 of 15 ASN Boise Casc" kN�NEF.RLD YgoD PRCDULI'$ Triple 1-3/4" x 18" VERSA -LAM® �----- 2.0 3100 SP PASSED 2nd Floor Deck - 1st Floor Walls\Flush Beams\FB2-3(i249) (Flush Beam) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1 st Flo ... \Flush Beams\FB2-3(i249) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles Load Summary Live Dead Snow Wind Roof Tributary Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% Live 125% 33 E7(i111) Conc. Pt. (Ibs) L 12-00-00 12-00-00 Top -11 n\a 34 J12(i392) Conc. Pt. (Ibs) L 12-05-08 12-05-08 Back 207 69 n\a 35 E7(i111) Conc. Pt. (Ibs) L 13-04-00 13-04-00 Top 6 22 24 n\a 36 E7(i111) Conc. Pt. (Ibs) L 13-04-00 13-04-00 Top -11 n\a 37 J12(i385) Conc. Pt. (Ibs) L 13-09-08 13-09-08 Back 207 69 n\a 38 E7(i111) Unf. Lin. (lb/ft) L 13-10-04 15-02-04 Top 467 956 546 n\a 39 E7(i111) Conc. Pt. (Ibs) L 14-08-00 14-08-00 Top 6 22 24 n\a 40 E7(i111) Conc. Pt. (Ibs) L 14-08-00 14-08-00 Top -11 n\a 41 J12(i359) Conc. Pt. (Ibs) L 15-01-08 15-01-08 Back 207 69 n\a 42 E7(i111) Unf. Lin. (lb/ft) L 15-10-04 17-02-04 Top 390 686 392 n\a 43 E7(i111) Conc. Pt. (Ibs) L 16-00-00 16-00-00 Top 6 22 24 n\a 44 E7(i111) Conc. Pt. (Ibs) L 16-00-00 16-00-00 Top -11 n\a 45 J12(i357) Conc. Pt. (Ibs) L 16-05-08 16-05-08 Back 207 69 n\a 46 E7(i111) Conc. Pt. (Ibs) L 17-04-00 17-04-00 Top 6 22 24 n\a 47 E7(i111) Conc. Pt. (Ibs) L 17-04-00 17-04-00 Top -11 n\a 48 J12(i394) Conc. Pt. (Ibs) L 17-09-08 17-09-08 Back 207 69 n\a 49 E7(i111) Unf. Lin. (lb/ft) L 17-10-04 19-02-04 Top 384 665 380 n\a 50 E7(i111) Conc. Pt. (Ibs) L 18-08-00 18-08-00 Top 6 22 24 n\a 51 E7(i111) Conc. Pt. (Ibs) L 18-08-00 18-08-00 Top -11 n\a 52 J12(i353) Conc. Pt. (Ibs) L 19-01-08 19-01-08 Back 207 69 n\a 53 E7(i111) Conc. Pt. (Ibs) L 20-00-00 20-00-00 Top 4 15 16 n\a 54 E7(i111) Conc. Pt. (Ibs) L 20-00-00 20-00-00 Top -7 n\a 55 E7(i111) Conc. Pt. (Ibs) L 20-04-12 20-04-12 Top 1 4 4 n\a 56 E7(i111) Conc. Pt. (Ibs) L 20-04-12 20-04-12 Top -2 n\a Controls Summary Value %Allowable Duration Case Location Pos. Moment 44022 ft-Ibs 54.7% 115% 4 10-08-00 End Shear 9308lbs 45.1% 115% 4 01-11-08 Total Load Deflection L/392 (0.601") 61.2% n\a 4 10-08-00 Live Load Deflection L/730 (0.323") 49.3% n\a 11 10-08-00 Max Defl. 0.601" n\a n\a 4 10-08-00 Span / Depth 13.1 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 5-1/2" x 5-1/4" 10768 Ibs 5.3% 49.7% Unspecified 132 Wall/Plate 5-1/2" x 5-1/4" 8687 Ibs 4.3% 40.1% Unspecified Cautions Concentrated side load(s) 6,52 are closer than 18" from end of member. Please consult a technical representative or Professional of Record. Page 6 of 15 Boise Cascade Triple 1-3/4" x 18" VERSA -LAM® 2.0 3100 SP PASSED 2nd Floor Deck - 1st Floor Walls\Flush Beams\FB2-3(i249) (Flush Beam) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1 st Flo ... \Flush Beams\FB2-3(i249) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. 1-3/4" x 18" VERSA -LAM® 2.0 3100 SP is a discontinued product. Discontinued products are not available for purchase. Calculation based on user input of unbraced length of Top: 00-00-00 and Bottom: 00-00-00. Connection Diagram: Full Lenqth of Member �h— —ri; a minimum = 2" c = 6-1/2" b minimum = 3" d = 24" e minimum = 3" Calculated Side Load = 276.0 Ib/ft Nailing applies to both sides of the member Connectors are: 16d Common Nails Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMERC , AJSTM, ALLJOISTC , BC RIM BOARD TM, BCI® , BOISE GLULAMTI^, BC FloorValue® , VERSA -LAME, VERSA -RIM PLUSO , Page 7 of 15 Boise cascade` mameraeoow;on accoxrs Double 1-3/4" x 11-7/8" VERSA -LAME 2.0 3100 SP PASSED ---. -...-- �� 2nd Floor Deck - 1st Floor Walls\Dropped Beams\BM1-2(i415) (Dropped Beam) BC Design Engine Member Report Dry 11 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1st Flo ... opped Beams\BM1-2(i415) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles ♦ : . : . . : : : : . 2 o 12-09-06 B1 B2 Total Horizontal Product Length = 12-09-06 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1. 2" 926 / 0 2125 / 0 1998 / 0 82, 5-1/2" 980 / 0 2232 / 0 2092 / 0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self -Weight Unf. Lin. (lb/ft) L 00-00-00 12-09-06 Top 12 00-00-00 1 E8(i114) Unf. Lin. (lb/ft) L 00-00-00 12-09-06 Top 229 320 n\a 2 User Load Unf. Lin. (lb/ft) L 00-00-14 12-09-06 Top 150 100 n\a Controls Summary Value % Allowable Duration Case Location Pos. Moment 13083 ft-Ibs 53.5% 115% 3 06-02-15 End Shear 3531 Ibs 38.9% 115% 3 01-01-14 Total Load Deflection L/405 (0.364") 59.2% n\a 3 06-02-15 Live Load Deflection L/798 (0.185") 45.1 % n\a 6 06-02-15 Max Defl. 0.364" n\a n\a 3 06-02-15 Span / Depth 12.4 Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Hanger 2" x 3-1/2" 4318 Ibs n\a 82.2% Hanger B2 Wall/Plate 5-1/2" x 3-1/2" 4536 Ibs 3.4% 31.4% Unspecified Cautions Hanger model Hanger was not found.Hanger has not been analyzed for adequate capacity. Notes Design meets Code minimum (L/240) Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. 1-3/4" x 11-7/8" VERSA -LAM® 2.0 3100 SP is a discontinued product. Discontinued products are not available for purchase. Calculation based on user input of unbraced length of Top: 00-00-00 and Bottom: 00-00-00. Page 1 of 15 Boise cascade Double 1-3/4" x 11-7/8" VERSA-LAM(g) 2.0 3100 SP cnvhkf:%EU'rv,OU PFt(;l„�YS —�- 2nd Floor Deck - 1st Floor Walls\Dropped Beams\BM1-2(i415) (Dropped Beam) PASSED BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1st Flo ... opped BeamslBM1-2(415) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles Connection Diagram: Full Length of Member a minimum = 2" c = 7-7/8" b minimum = 3" d = 24" Calculated Side Load = 0.0 Ib/ft Connectors are: 3-1/4 in. Pneumatic Gun Nails Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMERG , AJSTM ALLJOISTC , BC RIM BOARDT"", BCI® , BOISE GLULAMTM, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 2 of 15 Boise Cascade° Double 1-3/4" x 9-1/2" VERSA-LAMO LVL 2.1E 3100 SP PASSED 2nd Floor Deck - 1 st Floor Walls\Wall Headers\E4_Hd3(i238) (Wall Header) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St� Description: 2nd Floor Deck - 1 st Flo ... all Headers\E4_Hd3(i238) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles 61 04-02-06 B2 Total Horizontal Product Length = 04-02-06 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1, 3" 72410 2638 / 0 3390 / 0 1655 / 41 B2, 3" 796 / 0 2606 / 0 3337 / 0 1833 / 44 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self -Weight Unf. Lin. (lb/ft) L 00-00-00 04-02-06 Top 10 00-00-00 1 E10(i116) Unf. Lin. (lb/ft) L 00-00-00 01-11-06 Top 239 320 n\a 2 FB2-3(i249) Conc. Pt. (Ibs) L 02-02-04 02-02-04 Top 1520 4710 6075 3472 n\a 3 FB2-3(i249) Conc. Pt. (Ibs) L 02-02-04 02-02-04 Top -85 n\a Controls Summary Value % Allowable Duration Case Location Pos. Moment 10722 ft-Ibs 70.4% 115% 4 02-02-04 End Shear 5911 Ibs 81.4% 115% 4 03-01-14 Total Load Deflection L/999 (0.079") n\a n\a 4 02-02-04 Live Load Deflection L/999 (0.044") n\a n\a 11 02-02-04 Max Defl. 0.079" n\a n\a 4 02-02-04 Span / Depth 4.8 D/ Allow D/ Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 3" x 3-1/2" 6028 Ibs 8.2% 76.5% Unspecified B2 Wall/Plate 3" x 3-1/2" 5943 Ibs 8.1% 75.5% Unspecified Notes Design meets User specified (L/240) Total load deflection criteria. Design meets User specified (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALC® analysis is based on IBC 2009. Calculations assume unbraced length of Top: 04-02-06, Bottom. 04-02-06. Connection Diaaram: Full Lenath of Member Page 12 of 15 Boi" cascw Double 1-3/4" x 9-1/2" VERSA -LAM® LVL 2.1E 3100 SP PASSED EN.;iNlEH[b 1NYJP Riful1C15 �----- 2nd Floor Deck - 1 st Floor Walls\Wall Head ers\E4_Hd3(i238) (Wall Header) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1 st Flo ... all Headers\E4_Hd3(i238) City, State, Zip: Northampton , Ma Specifier: Customer: (:iDesigner: DH Code reports: ESR-1040 Company: rk Miles Connection Diagram: Full Length of Member a minimum = 2" c = 5-1/2" b minimum = 3" d = 24" Calculated Side Load = 0.0 Ib/ft Connectors are: 3-1/4 in. Pneumatic Gun Nails Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALCO, BC FRAMER@ , AJSTM, ALLJOISTO , BC RIM BOARD TM, BCIO , BOISE GLULAMT", BC FloorValue@ , VERSA -LAM®, VERSA -RIM PLUS@ , Page 13 of 15 Boise CaseW ENviNE[iED WOOD PNCD'JCiS Double 1-3/4" x 9-1/2" VERSA -LAM® 2.0 3100 SP l---_- PASSED 2nd Floor Deck - 1st Floor Walls\Wall Headers\E1_Hd1(i396) (Wall Header) BC Design Engine Member Report Dry 11 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: VV 2nd Floor Deck - 1st Flo ... all Headers\E1_Hd1(i396) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles ♦ • • • ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ i i + i i i i 10-02-00 B1 B2 Total Horizontal Product Length = 10-02-00 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B 1. 3" 1003 / 0 1950 / 0 1923 / 0 1099 / 0 B2, 3" 1003 / 0 1943 / 0 1903 / 0 1087 / 0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self -Weight Unf. Lin. (lb/ft) L 00-00-00 10-02-00 Top 10 00-00-00 1 Rim 1(A05) Unf. Lin. (lb/ft) L 00-00-00 10-02-00 Top 307 376 215 n\a 2 Smoothed Load Unf. Lin. (lb/ft) L 00-00-00 10-02-00 Top 197 66 n\a Controls Summary Value %Allowable Duration Case Location Pos. Moment 9757 ft-Ibs 60.8% 115% 5 05-01-00 End Shear 3699 Ibs 50.9% 115% 5 01-00-08 Total Load Deflection L/349 (0.337") 68.8% n\a 5 05-01-00 Live Load Deflection L/660 (0.178") 54.6% n\a 10 05-01-00 Max Defl. 0.337" n\a n\a 5 05-01-00 Span / Depth 12.4 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 3" x 3-1/2" 4144 Ibs 5.6% 52.6% Unspecified B2 Wall/Plate 3" x 3-1/2" 4122 Ibs 5.6% 52.3% Unspecified Notes Design meets User specified (L/240) Total load deflection criteria. Design meets User specified (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALCO analysis is based on IBC 2009. 1-3/4" x 9-1/2" VERSA -LAM& 2.0 3100 SP is a discontinued product. Discontinued products are not available for purchase. Calculation based on user input of unbraced length of Top: 00-00-00 and Bottom: 00-00-00. Page 8 of 15 Ak Boise casca Double 1-3/4" x 9-1/2" VERSA -LAM® 2.0 3100 SP PASSED 2nd Floor Deck - 1st Floor Walls\Wall Headers\E1_Hd1(i396) (Wall Header) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St b Description: 2nd Floor Deck - 1st Flo ... all Headers\E1_Hd1(i396) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles Connection Diaqram: Full Lenqth of Member a minimum = 2" c = 5-1/2" b minimum = 3" d = 24" Calculated Side Load = 0.0 Ib/ft Connectors are: 3-1/4 in. Pneumatic Gun Nails Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC@, BC FRAMERO , AJSTM, ALLJOISTO , BC RIM BOARD TM, BCIO , BOISE GLULAMTM, BC FloorValue@ , VERSA -LAM@, VERSA -RIM PLUS@ , Page 9 of 15 Boise Cascade' � Double 1-3/4" x 9-1/2" VERSA -LAM® 1.7 2650 SIP etvkF[etf.D'MYJD aftC�'�CiS �- -- 2nd Floor Deck - 1 st Floor Walls\Wall Headers\E3_Hd2(i413) (Wall Header) BC Design Engine Member Report Dry 11 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg File name: Greenburg.mmdl Address: 107 Franklin St Description: 2nd Floor Deck - 1 st Flo ... all Headers\E3 — Hd2(i413) City, State, Zip: Northampton , Ma Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles 1 1 1 1 0 Oft-07-12 B1 B2 Total Horizontal Product Length = 08-07-12 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live 61,3" 195/0 383/0 217/0 B2, 3" 195/0 383/0 217/0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self -Weight Unf. Lin. (lb/ft) L 00-00-00 08-07-12 Top 10 00-00-00 1 W6(i118) Unf. Lin. (lb/ft) L 00-00-00 08-07-12 Top 36 89 50 Ma Controls Summary Value %Allowable Duration Case Location Pos. Moment 1143 ft-Ibs 12.2% 115% 2 04-03-14 End Shear 438 Ibs 6.0% 115% 2 01-00-08 Total Load Deflection L/999 (0.033") n\a n\a 2 04-03-14 Live Load Deflection L/999 (0.022") n\a n\a 4 04-03-14 Max Defl. 0.033" n\a n\a 2 04-03-14 Span / Depth 10.4 % Allow % Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 3" x 3-1/2" 578 Ibs 0.8% 7.3% Unspecified B2 Wall/Plate 3" x 3-1/2" 578 Ibs 0.8% 7.3% Unspecified Notes Design meets User specified (1-1240) Total load deflection criteria. Design meets User specified (L/360) Live load deflection criteria. Design based on Dry Service Condition. BC CALCO analysis is based on IBC 2009. 1-3/4" x 9-1/2" VERSA-LAMO 1.7 2650 SP is a discontinued product. Discontinued products are not available for purchase. Calculations assume unbraced length of Top: 08-07-12, Bottom: 08-07-12. Connection Diagram: Full Length of Member b �d a I c Page 10 of 15 8oiseCascade . Double 1-3/4" x 9-1/2" VERSA -LAM® 1.7 2650 SIP PASSED 2nd Floor Deck - 1 st Floor Walls\Wall Head ers\E3_Hd2(i413) (Wall Header) BC Design Engine Member Report Dry 1 1 span I No cant. August 8, 2023 15:27:30 Build 8765 Job name: Greenburg "_J Address: 107 Franklin St City, State, Zip: Northampton , Ma File name: Greenburg.mmdl Description: 2nd Floor Deck - 1 st Flo ... all Headers\E3_Hd2(i413) Specifier: Customer: Designer: DH Code reports: ESR-1040 Company: rk Miles Connection Diagram: Full Length of Member a minimum = 2" c = 5-1/2" b minimum = 3" d = 24" Calculated Side Load = 0.0 Ib/ft Connectors are: 3-1/4 in. Pneumatic Gun Nails Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement (EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy, prior to anyone relying on such output as evidence of suitability for a particular application. The output here is based on building code -accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes. To obtain Installation Guide or ask questions, please call (800)232-0788 before installation. BC CALC®, BC FRAMER®, AJSTM, ALLJOIST®, BC RIM BOARD TM, BCID BOISE GLULAMT'f, BC FloorValue® , VERSA -LAM®, VERSA -RIM PLUS®, Page 11 of 15