Loading...
Structural Calculation - Signed (22) (1)RE:CERTIFICATION LETTER Project Address: BARRY GRUBER 128 BROOKSIDE CIR NORTHAMPTON, MA 01062 Design Criteria: - Applicable Codes = 2015 IBC/IEBC W/(780 CMR) 9th Edition, 2015 IRC W/(780 CMR) 9th Edition, ASCE 7-10 and 2015 NDS - Risk Category = II - Wind Speed = 117 mph, Exposure Category B, Partially/Fully Enclosed Method - Ground Snow Load = 40 psf - ROOF 1 & 2: 2 x 4 @ 24" OC, Roof DL = 9 psf, Roof LL/SL = 35 psf (Non-PV), Roof LL/SL = 27.4 psf (PV) To Whom It May Concern, July 18, 2023 This document is the property of Barun Corp and cannot be reproduced without prior consent.It is site specific and shall not be transferred to any other property, property owner,person(s),or entity.This document may include an expression of professional opinion by the engineer of record,which is based on his or her best knowledge,information provided by others,and belief.Other professionals may have different opinions.Barun Corp reserves the right to amend and/or supplement this document in the event additional information be uncovered or made available. A structural evaluation of loading was conducted for the above address based on the design criteria listed above. Existing roof structural framing has been reviewed for additional loading due to installation of Solar PV System on the roof. The structural review applies to the sections of roof that is directly supporting the Solar PV System. Based on this evaluation, I certify that the alteration to the existing structure by installation of the Solar PV System meets the prescriptive compliance requirements of the applicable existing building and/or new building provisions adopted/referenced above. Additionally, the Solar PV System assembly (including attachment hardware) has been reviewed to be in accordance with the manufacturer’s specifications and to meet and/or exceed the requirements set forth by the referenced codes. Sincerely, Barun Corp | Design and Engineering | 610.202.4506 | chrisk@baruncorp.com | www.baruncorp.com 1/4 ROOF PITCH 23° Limits of Scope of Work and Liability: The existing structure has been reviewed based on the assumption that it has been originally designed and constructed per appropriate codes.The structural analysis of the subject property is based on the provided site survey data.The calculations produced for this structure's assessment are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were made according to generally recognized structural analysis standards and procedures.All PV modules,racking and attachment components shall be designed and installed per manufacturer’s approved guidelines and specifications.These plans are not stamped for water leakage or existing damage to the structural component that was not accessed during the site survey.Prior to commencement of work,the PV system installer should verify that the existing roof and connections are in suitable condition and inspect framing noted on the certification letter and inform the Engineer of Record of any discrepancies prior to installation.The installer should also check for any damages such as water damage,cracked framing,etc.and inform the Engineer of Record of existing deficiencies which are unknown and/or were not observable during the time of survey and have not been included in this scope of work.Any change in the scope of the work shall not be accepted unless such change, addition, or deletion is approved in advance and in writing by the Engineer of Record. BARUN CORP RESULTS SUMMARY BARRY GRUBER, 128 BROOKSIDE CIR, NORTHAMPTON, MA 01062 MOUNTING PLANE STRUCTURAL EVALUATION MOUNTING PLANE ROOF 1 & 2 GOVERNING ANALYSIS IEBC IMPACT CHECK RESULT OK MOUNTING PLANE STANDOFF HARDWARE EVALUATION FOR WIND UPLIFT WIND UPLIFT DCR Barun Corp | Design and Engineering | 610.202.4506 | chrisk@baruncorp.com | www.baruncorp.com 2/4 PV Panels Weight =2.50 psf Hardware Assembly Weight =0.50 psf PV-DL =3.00 psf Existing Roofing Material Weight 2 Layer(s)=5.00 psf Underlayment Weight =0.50 psf Plywood/OSB Sheathing Weight =1.50 psf Framing Weight =0.73 psf No Vaulted Ceiling =0.00 psf Miscellaneous =1.50 psf Total Roof Dead Load R-DL =9.20 psf Roof Live Load Lo =20.00 psf Member Tributary Area At <200 ft2 ROOF 1 & 2 Pitch 23° or 5/12 Tributary Area Reduction Factor R1 =1.00 Roof Slope Reduction Factor R2 =0.95 Reduced Roof Live Load, Lr = Lo (R1) (R2)Lr =19.00 psf Ground Snow Load pg =40.00 psf Effective Roof Slope 23° Snow Importance Factor Is =1.00 Snow Exposure Factor Ce =1.00 Snow Thermal Factor Ct =1.10 Minimum Flat Roof Snow Load pf-min =35.00 psf Flat Roof Snow Load pf =35.00 psf Roof Slope Factor Cs-roof =1.00 Sloped Roof Snow Load on Roof ps-roof =35.00 psf Roof Slope Factor Cs-PV =0.78 Sloped Roof Snow Load on PV Panels ps-PV =27.40 psf BARUN CORP ROOF 1 & 2 LOAD CALCULATION BARRY GRUBER, 128 BROOKSIDE CIR, NORTHAMPTON, MA 01062 PV PANELS DEAD LOAD (PV-DL) ROOF DEAD LOAD (R-DL) Total PV Panels 2 x 4 @ 24 in. O.C. REDUCED ROOF LIVE LOAD (Lr) SNOW LOAD SLOPED ROOF SNOW LOAD ON ROOF (Non-Slippery Surfaces) Composite Shingle Roof SLOPED ROOF SNOW LOAD ON PV PANELS (Unobstructed Slippery Surfaces) Barun Corp | Design and Engineering | 610.202.4506 | chrisk@baruncorp.com | www.baruncorp.com 3/4 psf psf psf psf psf psf -10.41%OK WITH PV PANELS 13.56 34.43 Roof Live Load (Lr) = ROOF 1 & 2 EXISTING 9.20 WITH PV PANELS BARRY GRUBER, 128 BROOKSIDE CIR, NORTHAMPTON, MA 01062 EXISTING 12.20 0.00 BARUN CORP IEBC IMPACT CHECK Roof Snow Load (SL) =27.40 Roof Dead Load (DL) = 19.00 35.00 The requirements of section 807.4 of 2015 IEBC are met and the structure is permitted to remain unaltered. Load Increase (%) = (DL + Lr)/Cd = (DL + SL)/Cd = Maximum Gravity Load = 22.56 38.43 38.43 34.43 Barun Corp | Design and Engineering | 610.202.4506 | chrisk@baruncorp.com | www.baruncorp.com 4/4