Loading...
23A-146 (19) BP-2022-011 1 130 PINE ST COMMONWEALTH OF MAS ACHUSETTS 2N A-146-(01 ot. CITY OF NORTHAM ON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTE ED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARAN FUND (MGL c.142A) BUILDING PERMIT • Penult t HP-2022-011I PERMISSION IS HEREBY GRANTED TO: Project+ Contractor: License: Est.Cost: 15000 JOEL ZIMMERMAN 07431E Cons!.Class: Exp.Date:02'1111 2023 Use Group: Owner: FLORENCE CONGREGATIONAL CHURCH Lot Size(sq.11.1 Zoning: URr3 .dpplicant: JOEL ZIMMERMAN CARPENTRY Applicant Address Phone: Insurance: 341)WEST STREET NORTH FIATFIELD. MA 01066 ISSUED ON:02/03/2022 TO PERFORM THE FOLLOWING WORK: reinforcing floor structure POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: !louse# Foundation: Gas: Final: Final: Rough Frame: Rough: Fire Department Driveway Final: Fireplace/Chimney: Final: Oil: Insulation: Smoke: Final: 1-Iq-23 g% THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTH MPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. tii;.tnature: if (N3, Fees Paid: $195.00 Final Construction Con of Document qi,tti V To be submitted at completion o construction by a Registered Design Pro essional for work per the ninth ed'tion of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Sanctuary Floor Reinforcement Date: 11 July 20 3 Property Address: Florence Congregational Church, 130 Pine St eet, Florence MA Project: Check(x) one or both as applicable: X Existing Construction Project description: Reinforce Existing First Floor System for Assembly Live Load I, Ryan S. Hellwig, MA Registration Number: 37300 ST,Expiratio i, date: 30 June 2024,am a registered design professional, and I have prepared all design plans,computati o ns and specifications concerning': Architcctural X Structural Firc Llkctikal for the above named project and that to the best of my knowledge, i iormation, and belief such plans, computations and specifications meet the applicable provisions of th- Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I was present on the construction site on a periodic basis to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its respo ibility for the work performed on this project regarding the provisions of 780 CMR 107. Enter in the space to the right a "wet" or ;} `�\ electronic signature and seal: F YA i S.FELL1c STRUCTURAL No 37300 -„f , r a Phone number: 413-744-7444 Email: rh@rshpe.com Building Official Use Only Building Official Name: Permit No.: Date: Version 01 01 2018