Loading...
CS 30ft 4in Ridge Beam CalcCS Beam 2021.5.0.8 kmBeamEngine 2018.9.0.1 Materials Database 1587 31 Carolyn St Northampton Ma 3-16-23 9:45am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2018 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description:Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: 0.00 Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 10 PLF Deck Connection: Nailed Member Weight: 14.2 PLF Filename: Beam1 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 30' 4.00" 12' 1.00" 35 15 Snow 1 2 3 17 9 0 12 7 0 30 4 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 5.500" 1.975" 4494# -- 2 17' 9.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 8.000" 5.149" 11713# -- 3 30' 4.000" Wall SPF #3/Stud 2x or 4x End-Grain (650psi) 5.500" 1.500" 3028# -52# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Snow Dead 1 3133# 1361# 2 8011# 3702# 3 2313# 714# Design spans 17' 4.375" 12' 2.375" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS NOTE: Connection schedule for member requires special design consideration, consult a professional engineer. Design assumes continuous lateral bracing along the top chord. Design assumes maximum unbraced length of 0.00' along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 16299.'# 33390.'# 48% 7.33' Odd Spans D+S Negative Moment 18436.'# 33390.'# 55% 17.75' Total Load D+S Negative Unbrcd 18436.'# 33966.'# 54% 17.75' Total Load D+S Shear 5709.# 10706.# 53% 16.88' Total Load D+S Max. Reaction 11713.# 18200.# 64% 17.75' Total Load D+S TL Deflection 0.4851" 0.8682" L/429 8.2' Odd Spans D+S LL Deflection 0.3517" 0.5788" L/592 8.2' Odd Spans S Control: Max. Reaction DOLs: Live=100% Snow=115% Roof=125% Wind=160%