Loading...
Pierce Permit AppsThe Commonwealth of Massachusetts Board of Building Regulations and Standards Massachusetts State Building Code, 780 CMR Building Permit Application To Construct, Repair, Renovate Or Demolish a One- or Two-Family Dwelling FOR MUNICIPALITY USE Revised Mar 2011 This Section For Official Use Only Building Permit Number: _____________________ Date Applied: ______________________________ ___________________________________ ____________________________________________ ___________ Building Official (Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: ____________________________________________ 1.1a Is this an accepted street? yes_____ no_____ 1.2 Assessors Map & Parcel Numbers _____________________ ____________________ Map Number Parcel Number 1.3 Zoning Information: _______________ ___________________ Zoning District Proposed Use 1.4 Property Dimensions: _____________________ ____________________ Lot Area (sq ft) Frontage (ft) 1.5 Building Setbacks (ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c. 40, § 54) Public † Private † 1.7 Flood Zone Information: Zone: ___ Outside Flood Zone? Check if yes† 1.8 Sewage Disposal System: Municipal †On site disposal system † SECTION 2: PROPERTY OWNERSHIP1 2.1 Owner 1 of Record: ________________________________________ _________________________________________________ Name (Print) City, State, ZIP _____________________________________________ _________________ ___________________________________ No. and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2 (check all that apply) New Construction †Existing Building †Owner-Occupied †Repairs(s) †Alteration(s) †Addition † Demolition †Accessory Bldg. †Number of Units_____ Other †Specify:________________________ Brief Description of Proposed Work2:_________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials)Official Use Only 1. Building $1. Building Permit Fee: $_______ Indicate how fee is determined: †Standard City/Town Application Fee †Total Project Cost3 (Item 6) x multiplier _______ x _______ 2. Other Fees: $_________ List:_________________________________________________ ____________________________________________________ Total All Fees: $_______________ Check No. ______Check Amount: _______Cash Amount:______ †Paid in Full †Outstanding Balance Due:__________ 2. Electrical $ 3. Plumbing $ 4. Mechanical (HVAC) $ 5. Mechanical (Fire Suppression)$ 6.Total Project Cost:$ SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License (CSL) ________________________________________________________ Name of CSL Holder _________________________________________________________ No. and Street _________________________________________________________ City/Town, State, ZIP _________________________________________________________ __________________ ______________________________________ Telephone Email address _____________________ ______________ License Number Expiration Date List CSL Type (see below) _______________ Type Description U Unrestricted (Buildings up to 35,000 cu. ft.) R Restricted 1&2 Family Dwelling M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances I Insulation D Demolition 5.2 Registered Home Improvement Contractor (HIC) ______________________________________________________________ HIC Company Name or HIC Registrant Name ______________________________________________________________ No. and Street ________________________________________ ____________________ City/Town, State, ZIP Telephone _____________________ ______________ HIC Registration Number Expiration Date _______________________________________ Email address SECTION 6: WORKERS’ COMPENSATION INSURANCE AFFIDAVIT (M.G.L. c. 152. § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ……….  No ………..  SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER’S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property, hereby authorize_____________________________________________________ to act on my behalf, in all matters relative to work authorized by this building permit application. ______________________________________________________ ______________________ Print Owner’s Name (Electronic Signature) Date SECTION 7b: OWNER1 OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. _____________________________________________________________ ______________________ Print Owner’s or Authorized Agent’s Name (Electronic Signature) Date NOTES: 1.An Owner who obtains a building permit to do his/her own work, or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor (HIC) Program), will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2.When substantial work is planned, provide the information below: Total floor area (sq. ft.) _________________________ (including garage, finished basement/attics, decks or porch) Gross living area (sq. ft.) __________________ Habitable room count ______________________ Number of fireplaces______________________ Number of bedrooms _____________________ Number of bathrooms ____________________ Number of half/baths ______________________ Type of heating system ___________________ Number of decks/ porches __________________ Type of cooling system_____________________ Enclosed ______________Open _____________ 3.“Total Project Square Footage” may be substituted for “Total Project Cost” Phil SmithPhil Smith 6 Torrey St6 Torrey St Easthampton, MA 01027Easthampton, MA 01027 413-203-9088 applications.westma@trinity-solar.com CS CS-108025 9/29/20234/22/2024 U Trinity Solar Inc DBA Trinity Solar 20 Patterson Brook Road - Unit 10 West Wareham MA 02576 413-203-9088 170355 10/11/202110/11/2023 applications.westma@trinity-solar.com Please See Attached X X X x x City of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ● Municipal Building Northampton, MA 01060 CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number ________________ is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: ___________________________________________________ The debris will be transported by: Name of Hauler: ______________________________________________________ Signature of Applicant: __________________________________Date: ___________ Casella- 295 Forest Street, Peabody, MA 01960 Trinity Solar 7/13/2023 Northampton, MA July 10, 2023 212 Main St. Northampton, MA 01060 Trinity Solar No. 16 Mountain Street 2023-06-890931 Florence, MA 01062 MA License No. 56687 RE: LABOUNTY, KERRY D; PIERCE, MARJORIE A Trinity Solar | 4 Open Square Way, Suite 410 | Holyoke, MA | (413) 203-9088 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic [PV] system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing at Roof R3 is 2x6 at 16 o.c.; existing rafter span= 7' 8"; (horizontal projection) Conventional roof framing at Roof R4 is 2x6 at 16 o.c.; existing rafter span= 12' 0"; (horizontal projection) 2. Roof Loading: • 3.0psf dead load (pounds per square foot - PV panels, mounting rails & hardware) • 5.7psf - existing roof loads (1.7 psf - 2x6 framing, 1.5psf roof sheathing, 2.5 psf shingles) • Ground Snow Load - 40psf • Wind criteria - Exposure Category B, 117 mph wind 3. Existing Roof modification - none required; existing roof framing is acceptable for PV installation. This installation design is in general conformance with the manufacturers’ specifications and complies with all applicable laws, codes, and ordinances – specifically the International Building Code (2015 edition) and the International Residential Code (2015 edition), including all Massachusetts regulations and amendments. The spacing and fastening of the mounting brackets is a maximum of 48” o.c. between mounting brackets (staggered) and is secured using 5/16” diameter corrosive-resistant steel lag bolts. A minimum of 2½” of penetration (embedment) per lag bolt is required, which will resist all stated loads above – including wind shear. Per NDS Section 12.1.4, clearance holes - equal to the diameter of the shank - need to be bored into a primary framing member for the full-length of the threaded portion of the bolt to avoid splitting of the framing member. Regards, Ihor Bojcun, PE Structural Engineer - Trinity Solar NJ, ElectricalContractor business permit number34EB01547400 NJ, HIC reg. #13VH01244300 For other jurisdictions, please visit: http://www.trinity-solar.com/about-us/locations-and-licenses HOMEOWNERS AUTHORIZATION FORM I,, (print name) am the owner of the property located at address: . (print address) I hereby authorize Trinity Solar Inc. (“Trinity Solar”)and its employees, agents, and subcontractors, including without limitation,, to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System, Battery System, roofing or other Trinity Solar offerings located on my property, applying and obtaining permission and approval for interconnection with the electric utility company, and registration with any state and/or local incentive program(s). This authorization includesthe transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Without limitation to the generality of theforegoing Ispecifically authorize Trinity Solar et al. to populate technical details, fill-in, edit, compile, attach drawings, plans, data sheets and other documentation to, date, submit, re-submit, revise, amend and modify application, submission and certificationdocuments(“ApprovalsPaperwork”),includingthoseforwhichsignaturepagesareincluded herewith for my signature, in furtherance of the relatedtransaction, and I am providing any signatures to Approvals Paperwork for purposes of the foregoing. Trinity Solar will provide copies of Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force and effect until revoked. I acknowledge that theseauthorizations are not required to proceed withthe transaction andare not a condition of the related agreement included herewith but are being given for my own convenience and benefit in order to expedite the approvals processes. ElectricUtility Company: ElectricUtilityAccount No.: Name on Electric Utility Account: Customer Signature PrintName Date CorporateHeadquarters1-877-SUN-SAVES 2211AllenwoodRoadPh:732-780-3779 Wall,NewJersey07719Fax:732-780-6671 www.trinity-solar.com  FORINFORMATIONABOUTCONTRACTORSANDTHECONTRACTORS’REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. Marjorie Pierce June 15, 2023 16 Mountain Street Florence, Massachusetts 01062 United States National Grid 0365033049 Marjorie Pierce Marjorie Pierce INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 16 MOUNTAIN STREET FLORENCE, MA 01062 42.345252,-72.669150 MOUNTAIN STREET P1 ISSUED TO TOWNSHIP FOR PERMIT 7/11/2023 NO.DESCRIPTION DATE PIERCE, MARJORIE TRINITY ACCT #: 2023-06-890931 16 MOUNTAIN STREETFLORENCE, MA 01062 42.345252,-72.669150 PROPOSED PV SOLAR SYSTEM DRAWING DATE:7/11/2023 DRAWN BY: RM REVISED BY: DC SYSTEM SIZE:6.075kW AC SYSTEM SIZE:5kW MODULE COUNT:15 MODULES USED: HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY: NAT'L GRID UTILITY ACCT #: 0365033049 UTILITY METER #: 78799210 DEAL TYPE: SUNNOVA P1 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 0 PITCH: 40° ORIENTATION: 55° ROOF 2 MODULES: 0 PITCH: 43° ORIENTATION: 325° ROOF 3 MODULES: 10 PITCH: 43 ORIENTATION: 145 ROOF 4 MODULES: 5 PITCH: 40 ORIENTATION: 235 ROOF 5 MODULES: 0 PITCH: 37° ORIENTATION: 235° ROOF 6 MODULES: 0 PITCH: 37° ORIENTATION: 55° ROOF 7 MODULES: 0 PITCH: 28° ORIENTATION: 325° ROOF 8 MODULES: 0 PITCH: 28° ORIENTATION: 145° ***NOTE: 2021 NFPA 1 - 11.12.3.2.4.1PLAN VIEW TOTAL ROOF AREA: 1896.3 FT²PHOTOVOLTAIC ARRAY TOTAL AREA: 242.5 FT²ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 12.8% DC ACUD ep M N S270 9013522545315 42.345252,-72.669150 15 HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) 1 SE5000H-US000BEi4 BASEMENT OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. P1 ISSUED TO TOWNSHIP FOR PERMIT 7/11/2023 NO.DESCRIPTION DATE PIERCE, MARJORIE TRINITY ACCT #: 2023-06-890931 16 MOUNTAIN STREETFLORENCE, MA 01062 42.345252,-72.669150 PROPOSED PV SOLAR SYSTEM DRAWING DATE:7/11/2023 DRAWN BY: RM REVISED BY: DC SYSTEM SIZE:6.075kW AC SYSTEM SIZE:5kW MODULE COUNT:15 MODULES USED: HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY: NAT'L GRID UTILITY ACCT #: 0365033049 UTILITY METER #: 78799210 DEAL TYPE: SUNNOVA P1 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS E SQUARE DDU222RB 60A UNFUSEDDISCONNECT ISOLATED NEUTRAL 240V 1Ø B NOTE:INTERNAL REVENUE GRADE MONITORINGCONTAINED WITHIN SOLAR EDGE INVERTERSOLAR EDGE PN. RWND-3D-240-MB INVERTER #1 - SE5000H-US000BEi4 DC AC Imp 13.5 Pout 5000 Vmp 380 Imax 21 Voc 480 OCPDmin 26.25 Isc 30 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) Imp 10.83 Vmp 37.39 Voc 45.34 Isc 11.17 A #6 THWN-2 GEC TO EXISTING GROUND ROD B 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-D SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 15 - 405W MODULES W/ 1 SOLAR EDGE S500B PER MODULE15 ADC MAX PER STRING 1 STRING OF 7 MODULES IN SERIES - 380 Vmax1 STRING OF 8 MODULES IN SERIES - 380 Vmax *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 f 8"x8"JUNCTION BOX NEUTRALEXISTING MAIN BREAKER / METER PAN COMBO M EXISTING 120/240VUTILITY METERMETER MAIN COMBO 200A MAIN BREAKER200A BUSBAR 240V 1Ø NEUTRAL240V 1Ø 200 MAIN BREAKER200A BUSBAR 2p200A 2p200A EXISTING MAIN BREAKER LOADCENTER 2p30A BACK FEED BREAKER NEC 705.12 2p30ASUPPLYING UTILITY 1Ø 120/240VP1 ISSUED TO TOWNSHIP FOR PERMIT 7/11/2023 NO.DESCRIPTION DATE PIERCE, MARJORIE TRINITY ACCT #: 2023-06-890931 16 MOUNTAIN STREETFLORENCE, MA 01062 42.345252,-72.669150 PROPOSED PV SOLAR SYSTEM DRAWING DATE:7/11/2023 DRAWN BY: RM REVISED BY: DC SYSTEM SIZE:6.075kW AC SYSTEM SIZE:5kW MODULE COUNT:15 MODULES USED: HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY: NAT'L GRID UTILITY ACCT #: 0365033049 UTILITY METER #: 78799210 DEAL TYPE: SUNNOVA P1 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ARRAY CIRCUIT WIRING NOTES1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS ANDEXECUTING INSTALLATION IN ACCORDANCE WITHNEC 2023 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULBTEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP =33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAICSOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH:POSITIVE CONDUCTORS = REDNEGATIVE CONDUCTORS = BLACKNEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITYNEC 705.12(B)(3)(2) 13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVEA NEMA 3R RATING CALCULATIONS FOR CURRENT CARRYING CONDUCTORSREQUIRED CONDUCTOR AMPACITY PER STRING[NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITYAMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 4 CCC: 0.80(40*.96)0.80 = 30.72A 30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY21.00A*1.25 = 26.25A AWG #10, DERATED AMPACITYAMBIENT TEMP: 30°C, TEMP DERATING: 1.0RACEWAY DERATING <_ 3 CCC: N/A40A*1.0 = 40A 40A >_ 26.25A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTIONTOTAL INVERTER CURRENT: 21.00A21.00A*1.25 = 26.25A--> 30A OVERCURRENT PROTECTION IS VALID SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 5/26/2023 Arthur J. Gallagher Risk Management Services, LLC 4000 Midlantic Drive Suite 200 Mount Laurel NJ 08054 856-482-9900 856-482-1888 CherryHill.BSD.CertM@AJG.com Gotham Insurance Company 25569 TRINHEA-03 National Union Fire Insurance Company of Pittsburg 19445Trinity Solar Inc. 4 Open Square Way, Suite 410 Holyoke, MA 01040 Endurance American Specialty Ins Co 41718 Liberty Insurance Underwriters Inc 19917 129732996 A X 2,000,000 X 100,000 5,000 1,000,000 2,000,000 X GL202100013378 6/1/2023 6/1/2024 2,000,000 B 2,000,000 X CA 2960145 6/1/2023 6/1/2024 A C D X 5,000,000 X EX202100001871 ELD30006989101 1000231834-06 6/1/2023 6/1/2023 6/1/2023 6/1/2024 6/1/2024 6/1/2024 5,000,000 Limit x of $5,000,000 19,000,000 B XWC 13588107 6/1/2023 6/1/2024 1,000,000 1,000,000 1,000,000 B Automobile Comp/ Collusion Ded.CA 2960145 6/1/2023 6/1/2024 All Other Units Truck-Tractors and Semi-Trailers $250/500 $250/500 Evidence of Insurance Evidence of Insurance JOB NAME:PIERCE, MARJORIE ADDRESS:16 Mountain Street Florence, MA 0106242.345252,-72.669150 42.095 ESTIMATED PERSONNEL HOURS 1.75 DAYS 1.32 DAYS 0.88 DAYS •15 HANWHA 405's (6.075KW)(CREW OF 3) (CREW OF 4) (CREW OF 6) •2 SEPARATE ARRAYS • 21' PEAK TO GROUND •4 PORTRAIT & 11 LANDSCAPED •1 INVERTERS INSTALLED OUTSIDE • NO TRENCH ESTIMATED SENT TO JOB USED □HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405)15 ______ □S500B SE OPTIMIZERS 15 ______ □ SE5000H-US000BEi4 1 ______ □LEVITON 2p30A BACKFEED BREAKER 1 ______ □ 60A OUTDOOR NON-FUSED DISCONNECT 1 ______ □SOLADECK BOX(ES) & HAYCO CONNECTOR(S)2 ______ □ PV LEAD WIRE 100'______ □CASE(S) OF BLACK SPRAY PAINT 1 ______ □CASE(S) OF TAR 1 ______ □ ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 14 ______ □ECOFASTEN 2012013 CF RAIL SPLICE 9 ______ □ ECOFASTEN 2099017 CF END CLAMP 32MM BLK 20 ______ □ ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 20 ______ □ECOFASTEN 4011011 MODULE JUMPER 3 ______ □GROUNDING LUG (NOT PROVIDED BY ECOFASTEN)2 ______ □ ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 52 ______ □ ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 52 ______ □ ECOFASTEN 2012019 CF MLPE MOUNT 15 ______ □ ECOFASTEN 2012020 CF WIRE MGMT CLIP 15 ______ □ ECOFASTEN 2012024 CF END CAP 20 ______ MATERIAL LIST (FOR INTERNAL USE ONLY) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 16 MOUNTAIN STREET PIERCE, MARJORIE 16 MOUNTAIN STREET FLORENCE, MA 01062 42.345252,-72.669150 APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNTobelocatedonallDCjunctionboxes and every 10'on DC conduit WARNING:PHOTOVOLTAIC POWER SOURCE NEC 690.31(D)(2) NEC 690.56(C) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PHOTOVOLTAIC DC DISCONNECT DC Junction Box 690.56(C)(2)NEC 690.4(B) MAXIMUM DC VOLTAGEAWARNING ELECTRICAL SHOCK HAZARD OF PV SYSTEMFLAPIDSHUTDOWN SWITCH FOR SOLAR PV SYSTEM DO NOT TOUCH TERMNALSHMMNALSONBOTHUNtANDLOWSOLSMAYattNLROIZED.M THE C«*N POSITION NEC 690.53 Service Disconnect NEC 690.13 (B)690.56(C)(2) Soladeck A WARNING DUAL KMftn SOURCEMtxmommanmorovoimcam?A WARNING PHOTOVOLTAIC DC DISCONNECT SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN Utility ELECTRICAL SHOCK HAZARO DO NOT TOUCH TERMNALSiRABNALSONBOTHUNEAND DES MAY NEC 690.4(B)LOAD SI BE ENERGIZEDINTHEOPENPOSITIONIRNRAPIDSHUTDOWN SWITCH TO THE "OFF"POSITION TO PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SHU XJWN NEC 690.13(B) MAXIMUM DC VOLTAGENEC690.56(C)PHOTOVOLTAIC AC DISCONNECT VAXIAM AT 0^3*3l>f,QjPBrNT CAY\.0^*'SO AC V0 _ WGd OF PV SYSTEM NEC 690.53IfSystemisBackfedBreakerNEC690.54 DOI NEC 705.12(B)(3)(2) PHOTOVOLTAIC AC DISCONNECT DC DisconnectNEC690.54 Utility Meter Socket A WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TEHMMALSTERMINALSONBOTHUNCANDLOADSIDESMAYBEENERGIZED^IN THE OPEN POSITIONAWARNINGPHOTOVOLTAICACDISCONNECT VAXfcLM x a=R«wj ••KAr.X.M3 AC V0.WG; ELECTRICAL SHOCK HAZARD NEC 690.13(B)oo NOT TOUCH nTERWALSONBOR LOAD Slots MAY^IN THE OPEN I LINE UC LNEROIANDIZEO NEC 690.54 NEC 690.13 (B) DC Conduit Load Center (To Combine Inverters) Enphase Envoy BoxMainServicePanelPhotovoltaic AC Disconnect Inverter (s)Solar Meter Socket NOTES: 1.) COMPLIES WITH NEC 2023 2.) REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.) STICKERS, LABELS, AND PLACKARDS SHALL BE OF SUFFICIENT DURRABILITYTO WITHSTAND THE ENVIROMENT INVOLVED solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules POWER OPTIMIZER 25 YEAR WARRANTY * Functionality subject to inverter model and firmware version © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: November 8, 2022 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 S500B UNIT INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 125 Vdc MPPT Operating Range 8 – 60 12.5 – 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight (including cables) 655 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) For ambient temperatures above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6) See(6) 13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. * 45mm for S500B APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC), 527 CMR 12.00 City or Town of: __________________________________ Date: ___________________ To the Inspector of Wires: By this application, the undersigned gives notices of his or her intention to perform the electrical work described below. Location (Street & Number): ____________________________________________ Unit No.: ________________________ Owner or Tenant: __________________________________________ Email: ____________________________________ Owner’s Address: ____________________________________________________ Phone No.: ______________________ Is this permit in conjunction with a building permit? (Check appropriate box) Yes No Permit No.:_________________ Purpose of Building: _____________________________________ Utility Authorization No.: ___________________ Existing Service: _____________ Amps _____/_____ Volts Overhead Underground No. of Meters: _____ New Service: _____________ Amps _____/_____ Volts Overhead Underground No. of Meters: _____ Description of Proposed Electrical Installation: _____________________________________________________________ ______________________________________________________________________________________________________ Completion of the following table may be waived by the Inspector of Wires. No. of Receptable Outlets: No. of Switches: Generator KW Rating: Type: No. Luminaires: No. of Recessed Luminaires: No. Wind Generators: Wind KW Rating: No. Appliances: KW: No. Water Heaters: KW: No. Transformers: Total KVA: Space Heating KW: Heating Equipment KW: No. Motors: Total HP: Total KW: No. Heat Pumps: Total KW: Total Tons: Fire Alarm System No. of Devices: Swimming Pool: In-Grnd. Above-Grnd. Hot-Tub No. of Self-Contained Detection/Alerting Devices: No. Oil Burners: No. Gas Burners: Video System No. of Devices: No. Air Conditioners: Total Tons: Telecom System No. of Outlets: No. Energy Storage Systems: KWH Storage Rating: Security System No. of Devices: Solar PV KW DC Rating: Solar PV KW AC Rating: No. of Modules: Roof-Mount Ground-Mount No. of Electric Vehicle Supply Equipment: Level 1 Level 2 Level 3 Rating: OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: _________________________________ (When required by municipal policy) Date Work to Start: _________________ Inspections to be requested in accordance with MEC Rule 10, and upon completion. FIRM NAME: ___________________________________________________ A-1 or C-1 LIC. No.: ____________ Master/Systems Licensee: __________________________________________ LIC. No.: __________________________ Journeyman Licensee: _____________________________________________ LIC. No.: __________________________ Security System Business requires a Division of Occupational Licensure “S” LIC. S-LIC. No.: __________________________ Address: ____________________________________________________________________________________________ Email: __________________________________________________________ Telephone No.: ________________________ I certify, under the pains and penalties of perjury, that the information on this application is true and complete. Licensee: ____________________________Print Name: ________________________________Cell. No.: _______________ INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability including “completed operation” coverage or its substantial equivalent. The undersigned certifies that such coverage is in force and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND OTHER Specify: _____________________________________ OWNER’S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the: (Check one) Owner Owner’s agent Owner / Agent: _______________________________________________ Tel. No.: ________________________________ Signature: ____________________________________________________ Email.: _________________________________ Commonwealth of Massachusetts Department of Fire Services BOARD OF FIRE PREVENTION REGULATIONS Official Use Only Permit No.: __________________________ Occupancy and Fee Checked: ____________ [Rev. 1/2023] Residential X TBD Trinity Solar Inc.4434 A1 Brian K. Macpherson Brian K. Macpherson 21233 A 32 Grove St, Plympton, MA 02367 applications.westma@trinity-solar.com 413-203-9088 508-577-3391Brian Macpherson X X 12525 B Install kW solar on roof. () panels INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 16 MOUNTAIN STREET FLORENCE, MA 01062 42.345252,-72.669150 MOUNTAIN STREET P1 ISSUED TO TOWNSHIP FOR PERMIT 7/11/2023 NO.DESCRIPTION DATE PIERCE, MARJORIE TRINITY ACCT #: 2023-06-890931 16 MOUNTAIN STREETFLORENCE, MA 01062 42.345252,-72.669150 PROPOSED PV SOLAR SYSTEM DRAWING DATE:7/11/2023 DRAWN BY: RM REVISED BY: DC SYSTEM SIZE:6.075kW AC SYSTEM SIZE:5kW MODULE COUNT:15 MODULES USED: HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY: NAT'L GRID UTILITY ACCT #: 0365033049 UTILITY METER #: 78799210 DEAL TYPE: SUNNOVA P1 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ROOF 1 MODULES: 0 PITCH: 40° ORIENTATION: 55° ROOF 2 MODULES: 0 PITCH: 43° ORIENTATION: 325° ROOF 3 MODULES: 10 PITCH: 43 ORIENTATION: 145 ROOF 4 MODULES: 5 PITCH: 40 ORIENTATION: 235 ROOF 5 MODULES: 0 PITCH: 37° ORIENTATION: 235° ROOF 6 MODULES: 0 PITCH: 37° ORIENTATION: 55° ROOF 7 MODULES: 0 PITCH: 28° ORIENTATION: 325° ROOF 8 MODULES: 0 PITCH: 28° ORIENTATION: 145° ***NOTE: 2021 NFPA 1 - 11.12.3.2.4.1PLAN VIEW TOTAL ROOF AREA: 1896.3 FT²PHOTOVOLTAIC ARRAY TOTAL AREA: 242.5 FT²ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 12.8% DC ACUD ep M N S270 9013522545315 42.345252,-72.669150 15 HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) 1 SE5000H-US000BEi4 BASEMENT OUTSIDE. OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE. P1 ISSUED TO TOWNSHIP FOR PERMIT 7/11/2023 NO.DESCRIPTION DATE PIERCE, MARJORIE TRINITY ACCT #: 2023-06-890931 16 MOUNTAIN STREETFLORENCE, MA 01062 42.345252,-72.669150 PROPOSED PV SOLAR SYSTEM DRAWING DATE:7/11/2023 DRAWN BY: RM REVISED BY: DC SYSTEM SIZE:6.075kW AC SYSTEM SIZE:5kW MODULE COUNT:15 MODULES USED: HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY: NAT'L GRID UTILITY ACCT #: 0365033049 UTILITY METER #: 78799210 DEAL TYPE: SUNNOVA P1 NOTES: 1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. M UD SP P DC AC ep D DC 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SD TS E SQUARE DDU222RB 60A UNFUSEDDISCONNECT ISOLATED NEUTRAL 240V 1Ø B NOTE:INTERNAL REVENUE GRADE MONITORINGCONTAINED WITHIN SOLAR EDGE INVERTERSOLAR EDGE PN. RWND-3D-240-MB INVERTER #1 - SE5000H-US000BEi4 DC AC Imp 13.5 Pout 5000 Vmp 380 Imax 21 Voc 480 OCPDmin 26.25 Isc 30 Vnom 240 PV MODULE SPECIFICATIONS HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405) Imp 10.83 Vmp 37.39 Voc 45.34 Isc 11.17 A #6 THWN-2 GEC TO EXISTING GROUND ROD B 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND C 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND D 3/4'' CONDUIT W/ 4-#10 THWN-2, 1-#10 THWN-2 GROUND E 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2, 1-#8 THWN-2 GROUND NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS INVERTER #1 PV+L1 L2 N PV-D SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS 15 - 405W MODULES W/ 1 SOLAR EDGE S500B PER MODULE15 ADC MAX PER STRING 1 STRING OF 7 MODULES IN SERIES - 380 Vmax1 STRING OF 8 MODULES IN SERIES - 380 Vmax *2 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 f 8"x8"JUNCTION BOX NEUTRALEXISTING MAIN BREAKER / METER PAN COMBO M EXISTING 120/240VUTILITY METERMETER MAIN COMBO 200A MAIN BREAKER200A BUSBAR 240V 1Ø NEUTRAL240V 1Ø 200 MAIN BREAKER200A BUSBAR 2p200A 2p200A EXISTING MAIN BREAKER LOADCENTER 2p30A BACK FEED BREAKER NEC 705.12 2p30ASUPPLYING UTILITY 1Ø 120/240VP1 ISSUED TO TOWNSHIP FOR PERMIT 7/11/2023 NO.DESCRIPTION DATE PIERCE, MARJORIE TRINITY ACCT #: 2023-06-890931 16 MOUNTAIN STREETFLORENCE, MA 01062 42.345252,-72.669150 PROPOSED PV SOLAR SYSTEM DRAWING DATE:7/11/2023 DRAWN BY: RM REVISED BY: DC SYSTEM SIZE:6.075kW AC SYSTEM SIZE:5kW MODULE COUNT:15 MODULES USED: HANWHA 405 MODULE SPEC #:Q.PEAK DUO BLK ML-G10+ 405 UTILITY COMPANY: NAT'L GRID UTILITY ACCT #: 0365033049 UTILITY METER #: 78799210 DEAL TYPE: SUNNOVA P1 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com ARRAY CIRCUIT WIRING NOTES1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS ANDEXECUTING INSTALLATION IN ACCORDANCE WITHNEC 2023 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP = -16°C 3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULBTEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP =33°C 4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS (ALL OF UNITED STATES) 5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(A) THROUGH (D) 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAICSOURCE AND OUTPUT CIRCUIT AS PER NEC 690.41 (A)(4) 7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH:POSITIVE CONDUCTORS = REDNEGATIVE CONDUCTORS = BLACKNEC 210.5(C)(2) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12” IF USED OUTDOORS 11.)OVERCURRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OF THE POINT OF CONNECTION NEC 690.9(A)(3)(2) 12.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITYNEC 705.12(B)(3)(2) 13.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED POSITIONS OR LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVEA NEMA 3R RATING CALCULATIONS FOR CURRENT CARRYING CONDUCTORSREQUIRED CONDUCTOR AMPACITY PER STRING[NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A AWG #10, DERATED AMPACITYAMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96 RACEWAY DERATING = 4 CCC: 0.80(40*.96)0.80 = 30.72A 30.72A >_ 18.75A, THEREFORE WIRE SIZE IS VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY21.00A*1.25 = 26.25A AWG #10, DERATED AMPACITYAMBIENT TEMP: 30°C, TEMP DERATING: 1.0RACEWAY DERATING <_ 3 CCC: N/A40A*1.0 = 40A 40A >_ 26.25A, THEREFORE AC WIRE SIZE IS VALID CALCULATION FOR PV OVERCURRENT PROTECTIONTOTAL INVERTER CURRENT: 21.00A21.00A*1.25 = 26.25A--> 30A OVERCURRENT PROTECTION IS VALID SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY 5/26/2023 Arthur J. Gallagher Risk Management Services, LLC 4000 Midlantic Drive Suite 200 Mount Laurel NJ 08054 856-482-9900 856-482-1888 CherryHill.BSD.CertM@AJG.com Gotham Insurance Company 25569 TRINHEA-03 National Union Fire Insurance Company of Pittsburg 19445Trinity Solar Inc. 4 Open Square Way, Suite 410 Holyoke, MA 01040 Endurance American Specialty Ins Co 41718 Liberty Insurance Underwriters Inc 19917 129732996 A X 2,000,000 X 100,000 5,000 1,000,000 2,000,000 X GL202100013378 6/1/2023 6/1/2024 2,000,000 B 2,000,000 X CA 2960145 6/1/2023 6/1/2024 A C D X 5,000,000 X EX202100001871 ELD30006989101 1000231834-06 6/1/2023 6/1/2023 6/1/2023 6/1/2024 6/1/2024 6/1/2024 5,000,000 Limit x of $5,000,000 19,000,000 B XWC 13588107 6/1/2023 6/1/2024 1,000,000 1,000,000 1,000,000 B Automobile Comp/ Collusion Ded.CA 2960145 6/1/2023 6/1/2024 All Other Units Truck-Tractors and Semi-Trailers $250/500 $250/500 Evidence of Insurance Evidence of Insurance JOB NAME:PIERCE, MARJORIE ADDRESS:16 Mountain Street Florence, MA 0106242.345252,-72.669150 42.095 ESTIMATED PERSONNEL HOURS 1.75 DAYS 1.32 DAYS 0.88 DAYS •15 HANWHA 405's (6.075KW)(CREW OF 3) (CREW OF 4) (CREW OF 6) •2 SEPARATE ARRAYS • 21' PEAK TO GROUND •4 PORTRAIT & 11 LANDSCAPED •1 INVERTERS INSTALLED OUTSIDE • NO TRENCH ESTIMATED SENT TO JOB USED □HANWHA 405 (Q.PEAK DUO BLK ML-G10+ 405)15 ______ □S500B SE OPTIMIZERS 15 ______ □ SE5000H-US000BEi4 1 ______ □LEVITON 2p30A BACKFEED BREAKER 1 ______ □ 60A OUTDOOR NON-FUSED DISCONNECT 1 ______ □SOLADECK BOX(ES) & HAYCO CONNECTOR(S)2 ______ □ PV LEAD WIRE 100'______ □CASE(S) OF BLACK SPRAY PAINT 1 ______ □CASE(S) OF TAR 1 ______ □ ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 14 ______ □ECOFASTEN 2012013 CF RAIL SPLICE 9 ______ □ ECOFASTEN 2099017 CF END CLAMP 32MM BLK 20 ______ □ ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 20 ______ □ECOFASTEN 4011011 MODULE JUMPER 3 ______ □GROUNDING LUG (NOT PROVIDED BY ECOFASTEN)2 ______ □ ECOFASTEN 2012022 CF UNIV L-FOOT MLL 3 52 ______ □ ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 52 ______ □ ECOFASTEN 2012019 CF MLPE MOUNT 15 ______ □ ECOFASTEN 2012020 CF WIRE MGMT CLIP 15 ______ □ ECOFASTEN 2012024 CF END CAP 20 ______ MATERIAL LIST (FOR INTERNAL USE ONLY) 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 16 MOUNTAIN STREET PIERCE, MARJORIE 16 MOUNTAIN STREET FLORENCE, MA 01062 42.345252,-72.669150 APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS 2211 Allenwood Road Wall, New Jersey 07719 877-786-7283 www.Trinity-Solar.com SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNTobelocatedonallDCjunctionboxes and every 10'on DC conduit WARNING:PHOTOVOLTAIC POWER SOURCE NEC 690.31(D)(2) NEC 690.56(C) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PHOTOVOLTAIC DC DISCONNECT DC Junction Box 690.56(C)(2)NEC 690.4(B) MAXIMUM DC VOLTAGEAWARNING ELECTRICAL SHOCK HAZARD OF PV SYSTEMFLAPIDSHUTDOWN SWITCH FOR SOLAR PV SYSTEM DO NOT TOUCH TERMNALSHMMNALSONBOTHUNtANDLOWSOLSMAYattNLROIZED.M THE C«*N POSITION NEC 690.53 Service Disconnect NEC 690.13 (B)690.56(C)(2) Soladeck A WARNING DUAL KMftn SOURCEMtxmommanmorovoimcam?A WARNING PHOTOVOLTAIC DC DISCONNECT SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN Utility ELECTRICAL SHOCK HAZARO DO NOT TOUCH TERMNALSiRABNALSONBOTHUNEAND DES MAY NEC 690.4(B)LOAD SI BE ENERGIZEDINTHEOPENPOSITIONIRNRAPIDSHUTDOWN SWITCH TO THE "OFF"POSITION TO PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SHU XJWN NEC 690.13(B) MAXIMUM DC VOLTAGENEC690.56(C)PHOTOVOLTAIC AC DISCONNECT VAXIAM AT 0^3*3l>f,QjPBrNT CAY\.0^*'SO AC V0 _ WGd OF PV SYSTEM NEC 690.53IfSystemisBackfedBreakerNEC690.54 DOI NEC 705.12(B)(3)(2) PHOTOVOLTAIC AC DISCONNECT DC DisconnectNEC690.54 Utility Meter Socket A WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TEHMMALSTERMINALSONBOTHUNCANDLOADSIDESMAYBEENERGIZED^IN THE OPEN POSITIONAWARNINGPHOTOVOLTAICACDISCONNECT VAXfcLM x a=R«wj ••KAr.X.M3 AC V0.WG; ELECTRICAL SHOCK HAZARD NEC 690.13(B)oo NOT TOUCH nTERWALSONBOR LOAD Slots MAY^IN THE OPEN I LINE UC LNEROIANDIZEO NEC 690.54 NEC 690.13 (B) DC Conduit Load Center (To Combine Inverters) Enphase Envoy BoxMainServicePanelPhotovoltaic AC Disconnect Inverter (s)Solar Meter Socket NOTES: 1.) COMPLIES WITH NEC 2023 2.) REFER TO SHEET PV-3 FOR SITE SPECIFIC VALUES REQUIRED BY NEC 690 3.) STICKERS, LABELS, AND PLACKARDS SHALL BE OF SUFFICIENT DURRABILITYTO WITHSTAND THE ENVIROMENT INVOLVED solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules POWER OPTIMIZER 25 YEAR WARRANTY * Functionality subject to inverter model and firmware version © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: November 8, 2022 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 S500B UNIT INPUT Rated Input DC Power(1) 440 500 W Absolute Maximum Input Voltage (Voc) 60 125 Vdc MPPT Operating Range 8 – 60 12.5 – 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight (including cables) 655 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) For ambient temperatures above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Inverter Single Phase SolarEdge Home Short String Inverter Three Phase Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6) See(6) 13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. * 45mm for S500B