Loading...
11C-027 126_Florence_St_ SPD permit packetPV SOLAR ARCHITECTURAL DRAWINGSSHEETSHEET INDEXSATELLITE IMAGEJOB NOTESPV SOLAR ELECTRICAL DRAWINGSPVE-1ELECTRICAL SINGLE -LINE DIAGRAM &PVE-2ELECTRICAL CALCULATIONPVE-3ELECTRICAL DATA & SPECIFICATIONSSPECIFICATIONSPVE-4PLACARD / CONDUCTOR & OCPD SIZING TABLEPVE-5BRANCH DIAGRAMPV SOLAR STRUCTURAL DRAWINGSPVS-1MOUNTING DETAILSCOVER SHEETPVA-0DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-2019PROJECT LOCATIONNTSPVA-0COVER SHEETPVA-1ARRAY LAYOUT1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0GRID-TIED PHOTOVOLTAIC SYSTEMSOLAR INDIVIDUAL PERMIT PACKAGEJAMES CHARLES FERGERSON126 FLORENCE STREET(507) 213-8065NORTHAMPTON / LEEDS, MASSACHUSETTS 010537.25 kWAHJ: NORTHAMPTONUTILITY: NATIONAL GRID - MASSACHUSETTSCODE INFORMATIONAPPLICABLE CODES, LAWS AND REGULATIONS2015 INTERNATIONAL BUILDING CODE (IBC)2015 INTERNATIONAL RESIDENTIAL CODE (IRC)2015 INTERNATIONAL FIRE CODE (IFC)2014 NATIONAL ELECTRIC CODE (NEC) ROOF ACCESSPOINT(E) POOL(E) GARAGE9:12ROOF 1: 15 MODULES8.5:12ROOF 2: 3 MODULES7:12ROOF 3: 3 MODULESTO ELECTRICUTILITY GRIDACDPV M N-LC M 74'-11"49'-2"NNNNSHEETARRAY LAYOUTPVA-1DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-2019NOTE:1.FIELD ADJUSTMENTS OF FEWERTHAN 6” MAY BE ALLOWED BASED ON SITECONDITIONS AND MEASUREMENTS.ROOF TYPECONTRACT MODULEINVERTER TYPESTORYSYSTEMROOF PITCH& QUANTITYAND QUANTITYHOME TYPEORIENTATIONCONSUMPTIONMONITORINGTBDROOF ATTACHMENTQUANTITYCOMPOSITION9:12 & 8.5:12 & 7:12 & 3.5:123 - STORY195° & 15°SPR-X21-345-D-AC (240) (21)SPR-X21-345-D-AC (240) (21)481/16" = 1'-0"L E G E N DJUNCTION BOXEXISTING SERVICE POINTPROPERTY LINEEXISTING UTILITY METERCONDUITACDAC DISCONNECTN-LCNEW LOAD CENTERUTILITY REVENUE METERMA SMARTPVMM1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0VENT PIPEROOF VENTSKYLIGHT FIGURE 3: MOUNTING CLAMPPOSITIONING DETAILSPV MODULEPV MODULEFIGURE 2: INVISIMOUNT ROOF ATTACHMENT DETAILS @ TRUSS / RAFTERSTABLE 2: PENETRATION GUIDE FOR INSTALLSTACKEDSTAGGEREDFULLY STAGGEREDSTACKED/STAGGEREDFULLY STAGGERED*CHECK TABLE 1 FOR MAX.. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY.TWO OR MORE ROWS OF MODULESONE ROW OF MODULES96 CELL MODULE·INVISIMOUNT RAILS SHALL BE POSITIONED IN THENON-CROSS HATCHED REGIONSTABLE 1 – ARRAYS INFORMATIONROOFPITCHROOFINGTYPEATTACHMENTTYPENO. OFSTORIESFRAMINGTYPEFRAMINGSIZEOCSPACINGMAX.SPANPENETRATIONPATTERNMAX.PENETRATIONSPACINGMAX. RAILOVERHANGROOF 137°Comp ShingleSunModo L-foot1Wood Rafter2x61.33'11.58'Fully Staggered4'1.33'ROOF 235°Comp ShingleSunModo L-foot1Wood Rafter2x62'7.08'Staggered4'1.33'ROOF 330.5°Comp ShingleSunModo L-foot1Wood RafterTRUE 2x42'5.75'Staggered4'1.33'ROOF 4----------------------ROOF 5----------------------ROOF 6----------------------CHECK TABLE 2 FOR PENETRATION PATTERN GUIDEFIG 1.1: ROOF 1 STRUCTURAL FRAMING DETAILFIG 1.2: ROOF 2 STRUCTURAL FRAMING DETAILFIG 1.3: ROOF 3 STRUCTURAL FRAMING DETAILTOP CHORD2x6 @ 16" O/CBOTTOM CHORD2x6 @ 16" O/CBOTTOM CHORDTOP CHORD11'-7"9'-7"FLASHINGPV MODULE3.5"MAX2"MIN INVISIMOUNTRAILL-FOOTLAG BOLTCOMPOSITESHINGLE1 LAYER1'PITCH37°WALLLIVE-IN ATTICTOP CHORD2x6 @ 24" O/CBOTTOM CHORDTOP CHORD7'-1"5'-5"FLASHINGPV MODULE3.5"MAX2"MIN INVISIMOUNTRAILL-FOOTLAG BOLTCOMPOSITESHINGLE1 LAYER9"PITCH35°TOP CHORDTRUE 2"x4" @ 24" O/CBOTTOM CHORDTOP CHORD5'-9"3'-11"FLASHINGPV MODULE3.5"MAX2"MIN INVISIMOUNTRAILL-FOOTLAG BOLTCOMPOSITESHINGLE1 LAYER1'PITCH30.5°3'-4"2'-2"ATTICSHEETSTRUCTURAL INFORMATION AND MOUNTING DETAILSPVS-1DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-2019NTS1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0 WITH EGC#12TYPE-ER, PERBRANCH CIRCUITELECTRICAL NOTESCHECK BOX FOR WHETHER SYSTEM IS GROUNDED ORUNGROUNDED:GROUNDED (INCLUDE GEC)UNGROUNDEDFOR UNGROUNDED SYSTEMS:·DC OCPD DISCONNECT BOTH CONDUCTORS OF EACHSOURCE CIRCUIT.·UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER210.5(C). WHITE FINISHED CONDUCTORS ARE NOTPERMITTED.üTAG123456789DC / DC CONVERTERSSOURCE CIRCUIT JUNCTION BOXSEPARATE DC DISCONNECTINTERNAL INVERTER DC DISCONNECTSTRING INVERTERSOLAR LOAD CENTERPV PRODUCTION METERSEPARATE AC DISCONNECTDESCRIPTIONNONOYES--1SOLAR AC MODULE / BRANCHACMSUNPOWER PROVIDED AC MODULES EXTENSIONCABLE, LISTED AS AN ASSEMBLYNONO#1221ROOFTOPARRAY WIRINGADCACDCAC1SUNPOWER MODULESSPR-X21-345-D-AC (240)Branch Circuit # 112 AC MODULESBranch Circuit # 29 AC MODULESNOEXISTINGGROUNDHINCOMING SOURCE FEED , 120/240V, 1PH, 3WTO EXISTINGLOADSPV BREAKER: TO BEINSTALLED ON THE OPPOSITE SIDEOF THE MAIN OCPD OF THE BUSSTOP FEDMCB *MSP MAX PV BREAKER (A) = X 120% - =LOCATION:MANUF:METER #:(E) MAIN SERVICE PANELLOCATION:EXTERIOR WALL(E) UTILITYBIDIRECTIONAL METER120/240V, 1PH, 3W200A200A, 2P40A, 2P200A40A, 2P200A, 2PINSIDE HOMEMURRAY62722327BRANCH CIRCUIT SUMMARYBRANCH #ROOF LOCATION123456ROOF 1- -ROOF 1, 2, 3 & 4- -- -- -NOTE:BELOW ARE OPTIONAL OFFERINGS AND SHALLONLY BE INSTALLED IF THE HOMEOWNER SIGNSA SPECIFIC CONTRACT WITH SUNPOWER:·SUNPOWER MONITORING SYSTEMBJUNCTION BOX,NEMA-3R,HOFFMAN A12R106OR EQUIVALENT3THWN-2EGC: THWN-214#10#10EMT3/4"15A, 2PETHERNETCONNECTION TODSL/CABLE MODEMCAT5eCCT12#14#14#22THWNAWG TWISTED PAIR (per CT)EGC: THWN#14#14#22EMT1/2"3EMT1/2"CDPCTPVS5XWITH VISIBLE KNIFE BLADESSQUARE D 9EYES3THWN-2EGC: THWN-21LOCATED OUTSIDEEDU222RB OR EQUIVALENTUTILITY-LOCKABLE SAFETY SWITCH 60A, 240VAC#8#10EMT3/4"CONDUCTOR / CONDUIT SCHEDULEDESCRIPTION &CONDUCTOR TYPECONDUCTOR SIZE(AWG)CONDUIT/CABLE TYPEATAGCONDUIT SIZENUMBER OFCONDUCTORSBCD (N) SOLAR LOAD CENTER MIN., 120/240 V,M.L.O, NEMA-3RMLOYES7LOCATION:20A, 2P20A, 2PNEAR METER100 A1.PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC.2.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS.3.MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED.4.EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS.5.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED.6.TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC REQUIREMENTS.7.IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY.8.AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%.9.RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT.10.EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE.11.AS DC POWER IS INTERNAL TO THE MODULE, GROUNDING ELECTRODE CONDUCTOR (GEC) FOR THE MODULE OR ARRAY IS NOT REQUIRED.MMA SMARTUTILITY REVENUE METERNOTE:MA SMART UTILITY REVENUEMETERS ARE BI-DIRECTIONAL,NET METER AND UTILITYOWNED. METER LOCATIONSDETERMINED BY UTILITY FORAMR ACCESS REQUIREMENTS.YES8SHEETELECTRICAL SINGLE-LINE DIAGRAM & SPECIFICATIONSPVE-1DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BYFIGURE A: SINGLE LINE DIAGRAM - 03-05-2019JBERNALES03-05-20197.25 kWNTS1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF SUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0 ELECTRICAL CALCULATIONSAC, BRANCH 1AC, BRANCH 2AC, SUBPANELROOF JCT BOX TO SUB-PANEL WIRING - BRANCH 1#10NUMBER OF MODULES PER BRANCH CIRCUIT12VOLTAGE240 VBRANCH CURRENT: IOUT =15.96 AMINIMUM WIRE AMPACITY: IMAX = IOUT x 1.2519.95 ACONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE36°CTEMPERATURE ADDER22°CTEMPERATURE USED FOR AMPACITY DE-RATING58°CTEMPERATURE DE-RATING COEFFICIENT0.58FILL DE-RATING COEFFICIENT0.80IWIRE_MIN = IMAX / TEMP_COEFF / FILL_COEFF34.40 AWIRE SIZE AMPACITY = MAX OF (Imax OR Iwire_min)34.40 AWIRE SIZE SELECTED BASED ON AMPACITY#10AMPACITY AT TERMINATION (>WIRE SIZE AMPACITY)35 ACONDUCTOR SIZE#10CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP#101.40%OVERCURRENT PROTECTION20A, 2PMINIMUM OCPD = IOUT x 1.2519.95 ANEXT LARGER OCPD SIZE20 AROOF JCT BOX TO SUB-PANEL WIRING - BRANCH 2#10NUMBER OF MODULES PER BRANCH CIRCUIT9VOLTAGE240 VBRANCH CURRENT: IOUT =11.97 AMINIMUM WIRE AMPACITY: IMAX = IOUT x 1.2514.96 ACONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE36°CTEMPERATURE ADDER22°CTEMPERATURE USED FOR AMPACITY DE-RATING58°CTEMPERATURE DE-RATING COEFFICIENT0.58FILL DE-RATING COEFFICIENT0.80IWIRE_MIN = IMAX / TEMP_COEFF / FILL_COEFF25.80 AWIRE SIZE AMPACITY = MAX OF (Imax OR Iwire_min)25.80 AWIRE SIZE SELECTED BASED ON AMPACITY#10AMPACITY AT TERMINATION (>WIRE SIZE AMPACITY)35 ACONDUCTOR SIZE#10CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP#101.05%OVERCURRENT PROTECTION20A, 2PMINIMUM OCPD = IOUT x 1.2514.96 ANEXT LARGER OCPD SIZE20 ASUB-PANEL TO GRID-TIE WIRING#8VOLTAGE240 VSUM OF BRANCHES: IOUT_TOTAL =27.93 AMINIMUM WIRE AMPACITY: IMAX = IOUT x 1.2534.91 ACONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE36°CTEMPERATURE USED FOR AMPACITY DE-RATING36°CTEMPERATURE DE-RATING COEFFICIENT0.96FILL DE-RATING COEFFICIENT1IWIRE_MIN = IMAX / TEMP_COEFF / FILL_COEFF29.09 AWIRE SIZE AMPACITY = MAX OF (Imax OR Iwire_min)34.91 AWIRE SIZE SELECTED BASED ON AMPACITY#8AMPACITY AT TERMINATION (>WIRE SIZE AMPACITY)50 ACONDUCTOR SIZE#8CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP#81.40%OVERCURRENT PROTECTION40A, 2PMINIMUM OCPD = IOUT x 1.2534.91 ANEXT LARGER OCPD SIZE40 AVOLTAGE DROP AT 85 FT DISTANCEVOLTAGE DROP AT 85 FT DISTANCEVOLTAGE DROP AT 10 FT DISTANCESHEETELECTRICAL CALCULATIONPVE-2DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-2019NTS1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF SUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0 1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,WEATHER RESISTANT AND SUITABLE FOR THEENVIRONMENT.2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITHMINIMUM 38" LETTER HEIGHT, WHITE ON RED BACKGROUND.3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACEDADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATIONCLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER ISOPERATED.4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DCCONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES,AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TOAVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS,AND AT ALL DC COMBINER AND JUNCTION BOXES.5.DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USEONLY APPROVED ADHESIVE.SIGNAGE NOTESELECTRICAL DATA & SPECIFICATIONSPHOTOVOLTAIC SYSTEM EQUIPPEDWITH RAPID SHUTDOWNAMPSVOLTSPHOTOVOLTAIC POINT OFINTERCONNECTIONWARNING: DUAL POWER SOURCE.SECOND SOURCE IS PHOTOVOLTAICSYSTEM··MAXIMUM RATED AC OUTPUT CURRENT:MAXIMUM OPERATING AC VOLTAGE:·PV SOLAR BREAKERDO NOT RELOCATE THISOVERCURRENT DEVICE···PHOTOVOLTAIC SYSTEMAC DISCONNECTRATED AC OUTPUT CURRENT:NOMINAL OPERATING AC VOLTAGE:·AMPSVOLTS27.93 A240 V27.93 A240 VSHEETELECTRICAL DATA & SPECIFICATIONSPVE-3DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-2019NTS1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0 ACDPVMN-LC MFIGURE 1: CONDUCTOR AND OCPD SIZING TABLEFILE: RP-69532-IP-PLSOLAR-PVE-4.dwg, USER: jbernales, DATE/TIME: Mar 12, 2019 - 1:27pm SHEETPVE-4DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-2019NTS1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OFSUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0POWER TO THIS BUILDING IS ALSOSUPPLIED FROM THE FOLLOWINGSOURCES WITH DISCONNECT(S)LOCATED AS SHOWN:CAUTION:ACDISCONNECTPHOTOVOLTAICARRAY ON ROOFSERVICE POINT &UTILITY METERINGSOLAR LOADCENTERFIGURE 2: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCESPLACARD SIGNAGE / CONDUCTOR AND OCPD SIZING TABLEPLACARD / CONDUCTOR AND OCPD SIZING TABLE126 FLORENCE STREETUTILITY REVENUEMETER MA SMART NNNN9:12ROOF 1: 15 MODULES8.5:12ROOF 2: 3 MODULES7:12ROOF 3: 3 MODULESPPPRRRACD PV M N-LC M PPPRRRPPPPPPPPPPPPPPPRRRRRRRRRRRRRRRSHEETBRANCH DIAGRAMPVE-5DRAWN BYDATE DRAWNDATE CHECKEDSCALECHECKED BY03-05-2019JBERNALES03-05-201927/256" = 1'-0"INSTALLER NAME:_____________________BRANCH VOLTAGES:1.2.3.4.5.6.1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. REPRODUCTION,DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF SUNPOWER CORPORATION IS STRICTLY FORBIDDEN.R E V I S I O N SSOLAR INDIVIDUAL PERMIT PACKAGE GRID-TIED PHOTOVOLTAIC SYSTEMREV DESCRIPTIONDATEDBCBPROJECTOPPORTUNITYJAMES CHARLES FERGERSON 126 FLORENCE STREET NORTHAMPTON / LEEDS, MASSACHUSETTS 01053 RP-695327.25 kW VIRIDIS ENERGYAPATEL1 5 L A N C A S T E R A V E. R E V E R E, M A 0 2 1 5 1 L I C. #: 1 8 5 9 2 5 V I R I D I S E N E R G Y S O L U T I O N S L L C E X P D A T E: 0 9 / 0 1 / 2 0 2 0LEGEND & SYMBOLS:6.5', RECEPTACLE/RECEPTACLE3.3', PLUG/PLUG5', PLUG/RECEPTACLE10', PLUG/PLUG10', RECEPTACLE/RECEPTACLE10', PLUG/RECEPTACLEEND CAPSDAISY CHAIN