Loading...
31B-046 (5) BP-2023-0739 15 SUMMER ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 31B-046-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0739 PERMISSION IS HEREBY GRANT D TO: Project# 2023 SOLAR Contractor: License: Est. Cost: 31000 EMPOWER ENERG i SOLUTIONS 019944 Const.Class: Exp.Date: 12/01/202: Use Group: Owner: A ARO STEIN JONATHAN D&MN Lot Size (sq.ft.) Zoning: URC Applicant: EMPO ' R ENERGY SOLUTIONS Applicant Address phone: Insurance: 30 OLD KINGS HWY S#1001 (475)221-2356 WC533SB2191Q011 DARIEN, CT 06820 ISSUED ON: 06/06/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 27 PANEL 10.94 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature:g I • >9 1 • I Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner '/1/ 7JUN _ 6 . , The Commonwealth of MassacIusetts, c 3 I° I Board of Building Regulations and Slannt�ax,& 'r..u,� F R �y '. Massachusetts State Building Code, 780 CMi 'a"`n i"',y a UNI IPALIT�' , N� E�r� JSE Building Permit Application To Construct,Repair, Renovate Or Demo '� '' '*evil,d Mar 2011 One-or Two-Family Dwelling This Section For Official Use Only Building ermit Number: 812- 1.,3 7 3 9 Date Applied: L111h��yS ///.2 6-6-zoz3 Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map& Parcel Numbers 15 Summer Street Northampton MA 01060 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private❑ Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Jonathan Aronstein Northampton MA 01060 Name(Print) City.State,ZIP 15 Summer Street (413)210-4800 jonaron29@gmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition gl Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify: Brief Description of Proposed Work'-: Installation of a safe and code compliant,grid-tied PV solar system on an existing residential roof.27 Panels/10.94 kw(dc) SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 4,000 I. Building Permit Fee: $ Indicate how fee is determined: 2. Electrical S 27,000 ❑ Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire S Suppression) Total All Fees` {�, Check No. heck Amount: 16 Cash Amount: 6.Total Project Cost: $ 31,000 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CSL-1099 12/1/2023 Lando Bates License Num Expiration Date Name of CSL Holder List CSL Type(see below) 51 Assabet Dr No.and Street Type Description Northborough MA 01532-2600 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted I&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 774-249-1687 permits@empowerenergy.co I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(MC) HIC-198351 4/5/2024 Empower Energy Solution Inc HIC registration Number Expiration Date HIC Company Name or HIC Registrant Name 30 OLD KINGS HWY S 81001Type your text permits@empowerenergy.co No.and Street Email address DARIEN CT 06820-4551 (203)-493-2977 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes O No O SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Empower Energy Solution Inc to act on my behalf,in all matters relative to work authorized by this building permit application. Jonathan Aronstein 05/31/2023 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Lando Bates 'a�+<saLr +C3a.' ca► 05/31/2023 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed_ Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD SIDE YARD SIDE YARD FRONT SETBACK FRONTAGE City of Northampton Massachusetts .A�,� tII 1.411 DEPARTMENT OF BUILDING INSPECTIONS „t 212 Main Street • Municipal Building , �D cc,* Northampton, MA 01060 ss'Njy CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: 720 S Washington street North Attleboro,MA 02760 The debris will be transported by: Name of Hauler: Empower Energy Solution Inc Signature of Applicant: Wita) Date: 05-31-2023 ._,..r..________.,.............,_ The Commonwealth of Massachusetts Department of Industrial Aceitle nts 1 Congress Street.Suite 100 Ilip ,..4,.., . 4, 44 Boston.MA0114-2017 *:,,N.,\--.7.•'..-e_J" www.mass.goridia ..-'-5-P-''' II in kers l'omprnsation Insurance Affidavit:Builders/Contractors/ElearicianstPlumbers. TO RE l'ILED Vill'H I DE PERMI l'[INC AllfillORITV. Applicant Information Please Print Leoihiv Name(Business;OrgatuzationlIndividual): Empower Energy Solutions Inc. Address: 30 OLD KINGS HWY S#1001 I City Statciir DARIEN CT 06820-4551 Phone#: 1i 203-493-2977 Are yea an Molloy re it b.i k the apprirpriats,Inn: Type of project(required) i 1M I am a employee with 10 doyees MIR autos part-urnai 7. []New construction 20 I ant a auk pruptletut or paristerstup and have no empluvreci onsrking for me an II. Ci Remodeling any c-zpaoty.[Nu skortert"comp.insurance si-mttinztli 9. 0 Demolition 3E31 ant a humeownet doimg all work neyself.(No workers'cony,imam:net reaps:rug' 10 El Building addon 4.C:3 i am a horneostmer sind will be hinnu contractors to inwiduct all work on inv property. I will ensure that all contractors either have ssusters:`compertsation insurance or am sole 11 a Electrical repairs or additions prophet's's with no employees.. 12.1:Plumbing repairs or additions SE:I I era a wizefa!cosi:tame and I Moe tweed the 14111.4.10121111COOtli listed on the attaihoil sheet i 30 ROO,f repairs These sub-cantractins Noe employexs and hoc workers'wrap.insurance:: 14.clOther PV Solat Installation +LC]We are a corporation acid its officer,have extacised their mitt of CittenritUrt pa MA,i.e. 152,4 1(4).and iwc hat,r?iii,employees.[Nis workers'eonm ttudzatice ictit.iiteJ.1 •Any apphcana that chocks Inn a I aunt alley fell out the acction below show ems thou-vx Luta"'couttpoMttab' an polity information Homenwireas who submit this aftisdniru indicating they are doing all work and then hire onisidec;tractors must submit a new atlidavii indicating s uch !Contractors that chock this box mod attached an additional where showing =en the oldie soh- tort anti date whether or not those conics ... ..lover:, tithe Ash-cuntraettes,have r..41,14.rytx_they nista pail-id,:mete workers' amp roliecy ratiedve I am an employer that is prodding workers'coimpensation insorance for no'employees. Below is the policy and job site information. Insurance Company Name: IN Insurance Corporation Policy#ot Self-ins.1.:,:. tt: WC533582191Q012 lExpiration Date: 11J03/2023 Job Site Address: 15 Summer Street City:StateZip: Northampton MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number arid expiration date). Failure to secure coverage as required under MC L e. 152,*25A is a criminal vicilation punishable by a tine up to SI,500.00 anilior one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a tine of up to S250.00 a day against die violator.A copy of this statement nary be lOrwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the:mins and penalties of perjury.that the information provided above is true and correct. 54,.... a , „ 1)„, 05-31-2023 Signature: . , Phone#: 203-493-2977 Official use only% Do not write in this area,to be completed by city or town official City or Town: Permit/license# Issuing A n thori t:i lc ircle oiler ! 1.Board of Health 2. Buildiip.:Department 3.Cityfforin Clerk 4.Electrical Inspector S.Plumbing Inspector 6.Other t:ontiii-i Person: Phone a: . ... ...... . Commonwealth of Massachusetts ,i! division of Occupational Licensure Board of Building Regulations and Standards '' i 11 TS ' * rvisc)r Cons v ion m CS109944 i , „..,,,. - Aires: 2 0 12 23 "°III ( 5 « LANDO BAT ` 5N1OASAETDy.,..„, IVE ' ` ` HBORo-- GA153 ` K E ir- ` > . / if r:54y1Litik,, Commissioner ,. A ® DATE(MMIDD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 11/07/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT 144ME: Brandy Jenkins WORLD INSURANCE ASSOCIATES LLC PHONE ); (508)699 7511 FAX No): ADDRESS: brandyjenkins@worldinsurance.com 656 Shrewsbury Ave suite 200 INSURER(S)AFFORDING COVERAGE NAIC f Tinton Falls NJ 07701 INSURERA: LM INS CORP 33600 INSURED INSURER B EMPOWER ENERGY SOLUTIONS INC INSURERC: INSURER D: 30 OLD KINGS HWY S 1001 INSURERE: _ DARIEN CT 06820 INSURERF: COVERAGES CERTIFICATE NUMBER: 832847 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP UNITS LTR INSD WVD POUCY NUMBER (MMIDDM'YY) (MM/DD/YYYY) COMMERCIAL GENERAL LIABIUTY EACH OCCURRENCED $ D CLAIMS-MADE OCCUR PR M SES(Ea ocAGE TO currence) $ MED EXP(My one person) $ N/A PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY E T LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ - OWNED SCHEDULED AUTOS ONLY AUTOS N/A BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY _ AUTOS ONLY (Per accident) $ UMBRELLA UAB _ OCCUR EACH OCCURRENCE $ - EXCESS LAB CLAIMS-MADE N/A AGGREGATE $ DED RETENTIONS $ WORKERS COMPENSATION X PERTUTE EH R AND EMPLOYERS'LABILITY ANYPROPRIETOR/PARTNER/EXECUTIVE Y/N EL EACH ACCIDENT $ 500,000 A OFFICER/MEMBEREXCLUDED? N/A NIA N/A WC533SB21910012 11/03/2022 11/03/2023 (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 500,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L DISEASE-POLICY LIMIT $ 500,000 N/A DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Workers'Compensation benefits will be paid to Massachusetts employees only.Pursuant to Endorsement WC 20 03 06 B.no authorization is given to pay claims for benefits to employees in states other than Massachusetts if the insured hires,or has hired those employees outside of Massachusetts. This certificate of insurance shows the policy in force on the date that this certificate was issued(unless the expiration date on the above policy precedes the issue date of this certificate of insurance). The status of this coverage can be monitored daily by accessing the Proof of Coverage-Coverage Verification Search tool at www.mass.gov/lwd/workers-compensation/investigations/. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Empower Energy Solutions Inc 10 Ramblewood Drive AUTHORIZED REPRESENTATIVE Rocky Hill NJ 06067 Daniel M.Crowley,CPCU,Vice President—Residual Market—WCRIBMA ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD DATE(MM/DD/YYYY) A `Ot ' CERTIFICATE OF LIABILITY INSURANCE ' 0S/08t2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY.CND CONFERS NO RIGHTS UPON THE CERTIFICATE MILDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSI7RA.NCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER'S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER IMPORTANT:If the certificate ladder is an ADDITIONAL INSURED.the polky(ies)most have ADDITIONAL INSURED provision or be endorsed If SUBROGATION IS WAIVED.subject to the terms and conditions of the policy,certain policies ma) require an endorsement.A saneeateat on this certificate toes ant mete rights to the reAakote balder ie Sou of such eadarseetenl(s). PRODUCER CONTACT NAME: Millennial Specialty Insurance LLC dbn Founder Shield PHONE(A/C No.Est):646-8S4-1058 I FAX(A/C No): 114E 25th St,Floor 4 EMAIL ADDRESS:coi[o.'Auedenhield.eoa New York New fork,10810 INSURER(S)AFFORDING COVERAGE NAIL a INSURER A:Wilshire Insurance Company INSURED INSURER B:Hartford Underwriters Ins Ca(Hartford) 3(1104 INSURER C:Discos Insurance Company tee. 10201) Empower Energy Solutions 30 OLD KINGS HWY S INSURER D: Darien,Connecticut,06820 INSURER E: INSURER.F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT.TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIF/CATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SI BR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD WA'D ( MM/DD/YYYY) (MM/DDVYYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE S1,0011,0011.04) ,CLAIMS MADE OCCUR DAMAGE TO RENTED SI00,000.00 PREMISES(Ea occurrence) MED EXP(Any one person) S5,000.00 A GEN'L AGGREGATE LIMIT APPLIES PER: BN➢0000550 02 12 iltir2022 12/06/2/123 PERSONAL&ADV INJURY S1,000.0110.00 POLICY„ PROJECT LOC GENERAL AGGREGATE S2,000.000.00 PRODUCTS-COMP;OPAGG S2.000.000.00 ,,.,.. OTHER AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) ANY AUTO BODILY INJURY(Per person) OWNED AUTOS ;SCHEDULED ONLY BODILY INJURY(Per accident) HIRED AUTOS ONLY NON-OWNED AUTOS PROPERTY DAMAGE(Per ONLY accident) UMBRELLA LIAB =EXCESS LIAB Each occurence OCCUR CLAIMS-MADE Aggregate WORKERS COMPENSATION AND EMPLOYERS'LIABILITY ';IPER STATI;IL: ANYP ROPRIETORIPARTNER/EXECUTIV YI's OTHER OFFICER.'MEMBER EXCLUDED? N (Mandatory in NH) E.L.EACH ACCIDEN SI.000,000.00 B Ryes,describe under DESCRIPTION OF OPERATIONS Iteloc N/A SS60UB-6RI9294.9-22 12!06/2022 1/106/2023 E.L.DISEASE-EA S 1,000,000.00 EMPLOYEE E.L.DISEASE-POLICY S I.1100,000.00 LIMIT C Errors A Omissions P100.254.633.2 05/10/2022 05,1(1/2023 SIJ1•1000 per net 01d00A00 in au DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101.tdditionai Remarks Schedule.may be attached if more space is required) Evidence only CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE Evidence onlyTHEREOF.NOTICE WILL BE DELIVERED IN ACCORDANCE MUM THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 0 • • 1, ©1988-2016 ACORD CORPORATION.All rights reserved. ACORD 25(2016/031 I'ht ACORD name and 104,are reoictered marks of AMR!) THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs & Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Out of State Corporation Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street - Suite 710 198351 04/05/2024 Boston, MA 02118 EMPOWER ENERGY SOLUTIONS INC Nd rw � .ter a ,.��- #"P •W .+va .4„,I 6'r ASIM HAFEEZ fs V ",` —4 2,-, 5444, Xiclree). 30 OLD KINGS HWY S titt SUITE 1001 ._ �____- DARIEN. CT 06820 Undersecretary Not valid without signature THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washingto , treet - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration '� , t` r" 4 `." Type: Individual LANDO BATES Registration: 179685 Expiration: 09/27/2024 51 ASSABET DRIVE NORTHBOROUGH, MA 01532 _ Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS I Office of Consumer Affairs & Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Individual Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 179685 ,i1 09/27/2024 Boston, MA 02118 I LANDO BATES ;' LANDO BATES ` i 51 ASSAS ET DRIVE u f,/ ,G --5 .5-- NORTHBOROUGH, MA 01532 `` Undersecretary Not valid without signature Empower Energy Solutions Inc. E 15 June street, Ste 2A,Woodbridge, CT 06525 MA Contractors Registration No.:198351 ENERGY SOLUTIONS RESIDENTIAL SOLAR INSTALLATION AGREEMENT Customer 1 Name: Jopafhan AronstPin Phone: (413)210-4800 Email: jonaron29(a gmail.com Customer 2 Name: Phone: Email: Street Address: 15 Summer Street Town: Northampton State: MA Zip: 01060 Solar Consultant Name: Ryan SPverin Phone: +1-413-687-7894 Email: ryan sQpmpowerPnPrgy cr1 PRELIMINARY DESCRIPTION OF THE PROJECT AND ESTIMATE OF THE SIGNIFICANT MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED Module Name: Quail 405 Mod.Quantity: 27 System size(kw) 10 935 Inverter: SolarFdge Structural & Electrical Requirement: If any additional work i.e., attic bracing, electric panel upgrade, re-roof, tree removal etc. is required up analysis of the site surveyor&structural engineer, an additional fee will be assessed upon the Customer. 4 (Customer Initials) PAYMENT TERMS: The Customer agrees to pay the Company the total amount of$ $58,108 (the"Total Price")in exchange for the System. This total does not reflect any incentives the Customer may be entitled to. Payment Method: Cash, 1 Financed, Financing Company Dividend Financed Projects: Financed projects are subject to payment schedule terms of Customer's financier. Payments will be made directly from financier to the Company. Cash Projects Payment Schedule (Applies to Cash Projects only) Installment 1 (30%): $ due immediately. Installment 2 (70% minus$1000): $ due upon permit submission. Installment 3($1000): $ due day of install completion. Notes: Net Metering (not SMART program) CUSTOMER AND SOLAR CONSULTANT HAVE REVIEWED THE ABOVE INFORMATION AND THE TERMS AND CONDITIONS ATTACHED,AND AGREE TO THIS AGREEMENT: Notice to Customer: (1) Do not sign this agreement if there are any blank spaces.(2)All contractors and subcontractors performing residential contracting services in Massachusetts must be registered with the director of consumer affairs and business regulations. Any inquiries concerning the registration of a contractor or subcontractor should be directed to the director of consumer affairs and business regulations. (3)You are entitled to a copy of this Agreement at the time you sign it.(4)You may at any time pay off the full, unpaid balance due under this Agreement and in so doing you may be entitled to receive a partial rebate of the finance charges.(5)The Company has no right to unlawfully enter your premises or commit any breach of the peace to repossess goods purchased under this Agreement. (6)You may cancel this Agreement if you did not sign the Agreement at the main office or a branch office of the Company, provided you notify the Company at its main office or branch office shown in the Agreement by registered or certified mail,that shall be posted not later than midnight of the third calendar day after the day on which the Customer signs the Agreement,excluding Sunday and any holiday on which regular mail deliveries are not made.See the attached notice of cancellation form for an explanation of Customer's rights. CUSTOMER 1 SOLAR CONSULTANT Signature: /e Jtv� Date Signed: 05/ 31 /2023 Signature: Date Signed: 05/31 /2023 CUSTOMER 2 Signature: Date Signed: (Terms and Conditions attached) 1 nor:Ifl 2f5010hf 94h9a36h97ga0Phphfa4573431 adfa37 f4' TERMS AND CONDITIONS THIS RESIDENTIAL SOLAR INSTALLATION AGREEMENT(this"Agreement")is made effective as of the date signed by the Customer (the "Effective Date"), between the Customer whose name and signature appears above, and Empower Energy Solutions, Inc.,a Connecticut corporation (the"Company").This Agreement relates to the installation of a certain System on the residential structure located at the address set forth above (the "Home"), which Home is owned by the Customer. 1. Installation Timeline. The Company will install or cause to be installed the System within a reasonable amount of time after execution of this Agreement but no later than 12 months from the date of a work order or last amendment to this Agreement (whichever occurs last). If a financing company is involved, the lender will require the Company to perform the installation with a required timeline. 2. System. The Company will provide the following to the Customer at the Home(collectively,the"System"): a. The Company will obtain any necessary permits,at the Company's cost.The Company is not be responsible for delays in work due to the actions of any permitting and regulatory agencies or their employees; and b. The Company will cause the complete installation of a roof mounted solar photovoltaic electric generation system, with the components and specifications set forth above (as described, the "Solar Equipment"), according to final plans and specifications to be provided by the Company and approved by the Customer.All work by the Company is brought to the existing electrical connection; once at the electrical connection point, the actual connection will need to be made by or under the direction of the electrical utility company. NOTICE: Installation of the System may require(i)drilling into various parts of the Home,and(ii)other interior or exterior work that may require access to non-visible areas.The Customer consents to the installation work described. 3. Total Price. The Customer agrees to pay the Company the Total Price in exchange for the System, on the payment terms shown above, and further agrees as follows: a. Change Orders/Extra Work. If the Customer, the Customer's agent or representative, or any governmental agency requires any changes to the System beyond what is initially agreed to by the Company,the cost for any such change will be added to the Total Price, and the term "Total Price" as used in this Agreement will mean the adjusted higher Total Price. The cost of any such change order will include direct labor, materials, subcontracts plus supervision, general conditions, overhead, and profit.The Customer will also be required to pay all expenses incurred by the Company because of unanticipated or unforeseen circumstances (such as a faulty roof or inadequate electric service). b. Cost Increases. Customer acknowledges that the System equipment and materials the Company will furnish and install are subject to cost increases.The Company will hold the Total Price for six months after execution of this Agreement or the date of the last signed amendment to this Agreement. After six months, if the cost of any equipment or material rises by any unusual amount because of circumstances beyond Company's control, including but not limited to market price fluctuations or a site audit that reveals the need for additional materials or labor,then the Company will have the right to present Customer with a change order for the with a new Total Price.Customer will have the right to accept or reject this new Total Price. If Customer does not accept the new Total Price, this Agreement will terminate and the Company will provide the Customer with a full refund of any amounts previously paid, and the parties will have no further obligations to one another. c. Ownership/Security Interest. Until the time that the Customer has paid Company the entire Total Price, the Customer grants the Company and its agents, employees, and representatives the right to enter the Home/property and remove the System in whole or in part. The Customer agrees the System are not a fixture but will remain personal property at all times until the entire Total Price has been paid to the Company. Ownership of the System will remain with the Company until the Customer has timely paid the full Total Price. To the extent the Customer may be considered the owner of the System, however, the Customer grants the Company a security interest in the System to secure payment of the Total Price and any other amounts due under this Agreement,and grants the Company the maximum rights available under applicable law in enforcing that security interest. The Company also may assert all rights under applicable state law relating to contractor/mechanic liens on real property,with respect to the Home and the Customer's property. 2 nor.ID- 5n 1 nbR94h9a3Rh979af1PhPhfa4573411 arifa37 / l 4. Contractor Registration. Pursuant to Mass. Gen. Laws c. 142A§ 1, et seq. all contractors and subcontractors performing residential contracting services must be registered with the director of consumer affairs and business regulations. Any inquiries concerning the registration of a contractor or subcontractor should be directed to the director of consumer affairs and business regulations. 5. Notice of Possible Mechanic's Lien.The undersigned Contractor(the Company)is about to perform work and/or furnish materials for the construction, erection, alteration, or repair upon the Customer's land at the address shown above under a Contract with the Customer. This is a notice that the undersigned Company and any other person(s) who provide(s) labor and materials for the improvements to the Customer's property under contract with the undersigned Company may file a mechanic's lien upon the land in the event of non-payment to them. It is the Customer's responsibility to assure themselves that those other persons under contract with the undersigned Company receive payment for their work performed and materials furnished for the construction, erection, alteration, or repair upon the land 6. Late Fees. The Customer must pay the Company a late fee of $150.00 on any late payment. A payment is considered a late payment if the payment is not received by the Company on or before the due date. 7. Interest on Overdue Payments. Any amount not paid when due will bear interest at the rate of 12% annually, beginning on the date that is 30 days after the due date. 8. Manufacturer Warranty.The manufacturer of the Solar Equipment and any associated components may provide a manufacturer's warranty. All warranties can be obtained by the Customer directly from the manufacturer and any claims for a manufacturer defect must be directed to the manufacturer and not the Company.The Company may assist the Customer in identifying any applicable manufacturer's warranty(ies) solely as a courtesy. THE COMPANY PROVIDES NO ADDITIONAL WARRANTY RELATING TO THE SOLAR EQUIPMENT,OTHER THAN THE LIMITED LABOR WARRANTY DESCRIBED IN THE NEXT SECTION BELOW.To the extent products,equipment, systems,or materials incorporated into the Work are specified and purchased by Customer, they shall be covered exclusively by the warranty of the manufacturer. There are no warranties that extend beyond the description of the face of any such warranty. For such incorporated items, ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. 9. Labor Warranty. The Company guarantees that the System will be free from installation defects for a period of ten years following the conclusion of onsite installation(the"Labor Warranty").This Labor Warranty does not cover any of the following: natural acts such as storms, winds, rain, or snow; damage covered or normally covered by homeowner's insurance such as falling tree branches, power outages, power surges; normal wear and tear of the roof, roof shingle failure,sub-structure failure,or siding or electrical system failures.The Labor Warranty also does not cover any damages caused by animals or by improper maintenance of the structure or the system or by any action of any person other than the Company. If the Customer discovers an installation defect within the Labor Warranty period,the Customer must immediately notify the Company in writing describing the nature of the defect. If the Company determines that the defect is due to defective workmanship on the part of the Company during installation,the Company will correct the defect at no additional charge to the Customer. If a part repair or replacement is required and is covered by the manufacturer's warranty,the Customer must first obtain warranty coverage from the manufacturer and only then will the Company remedy the workmanship defect. Customer will be responsible for all costs of all repairs and replacements not expressly covered by this Labor Warranty. 10. Roof Warranty. The Company, for a period of three years, warrants that, with respect to all roof penetrations made by the Company, such roof penetrations will be free from material defects in workmanship and will be sealed or flashed to eliminate any liquid or vapor penetration, and that such roof penetrations will not affect or otherwise diminish the strength, integrity,water-repelling or balance of any underlying roof structure. 11. Customer Responsibilities. The Customer agrees to provide the following in order to aid the Company in completing the System(any reference to the"Company"in this section also includes the Company's agents,employees, representatives, and subcontractors): a. The Customer must identify and stake any concealed pipes,conduits, utilities,or other equipment before the Company begins work on the System(the Customer agrees that the Customer is responsible for any damage caused to or by any concealed pipes, conduits, utilities not identified and staked as required); 3 f)nr.If)- 7f501 Oh644h9a3Ahg79anehwhfa4573431 arifa37 b. Inform the Company of any rules, regulations, restrictions,or covenants covering the Home that may impact the design and installation of the System; c. The Customer must prepare and implement a stormwater pollution and prevention plan if such a plan is required by any government agency; d. The Customer must provide prompt decision making to the Company regarding unspecified construction plans, designs, or specifications relating to the System; e. The Customer must make sure the Home is prepared for local government (city/county/town) inspection at the time of completion of the System; f. The Customer must cure any pre-existing code violations at the Home that relate in any way to the System; g. The Customer must grant and obtain all permissions require for the Company to connect the System to required utilities at the Home; and h. The Customer must make water and electrical utility services available to the Company for use in carrying out the Company's work; i. The Customer must make the Home and property available to the Company without interruption during the Company's normal working hours to permit completion of installation work. 11. Property Conditions. Customer will be responsible for the structural integrity of the location where the System are installed, including structural or electrical modifications necessary to prepare the Home for the System. The Company is not responsible for any known or unknown property conditions.The Company is not responsible and bears no liability for the malfunctioning of existing electrical equipment at the Home, including but not limited to the main electrical service panel, any major electrical devices, or any other fuses or similar devices. 12. Rebates/Incentives. Depending on the state and utility district in which Customer resides, Customer may be eligible for various state and local rebates and incentives.The rebate and incentive calculations the Company provides to Customer are estimates only. These estimates are based on certain assumptions that may not be applicable based on the circumstances specific to the System. However, actual rebates and incentives are variable as eligibility requirements, funding availability and rates may change. In an effort to assist Customer in capturing its rebate, the Company will use good faith reasonable efforts to help Customer secure applicable rebates and incentives, but the Company will have no financial obligation to Customer regarding actual rebate and incentive amounts received. Customer agrees to pay the Total Price in full regardless of the actual amount of rebates and/or incentives Customer receive. 13. Return of Goods/Equipment. If the Customer cancels this Agreement, the Customer agrees to make all goods and equipment received from the Company available to the Company for pickup by the Company, or delivery back to the Company by mail or other courier service. If the Customer cancels this Agreement at any time that is more than three business days after the date of execution, for any reason other than that the Company deems the Home not suitable for the System,then the Customer will be required to pay the Company a cancellation fee equal to$3,000.00, in recognition of the fact that the Company will immediately incur costs relating to the design and installation of the System. The Company will pay for or reimburse the Customer for any mailing/delivery expenses relating to return of the goods and equipment.The goods and equipment must be in the same condition and form as they were when first provided by the Company to the Customer. 14. Privacy/Publicity. Customer grants the Company the right to publicly use, display, share, and advertise the photographic images, project details, price and any other non-personally identifying information of Customer's project. The Company will not knowingly release any personally identifiable information about Customer or any data associating Customer with the project location. Customer may opt-out of these publicity rights by giving the Company written notice and mailing it to the Company's address on the first page of these Terms and Conditions. 15. Default/Remedies. The failure of the Customer or the Company to comply with any term in this Agreement will constitute a material default, meaning a significant breach of this Agreement. Upon default by the Customer, the Company may immediately stop all work on the System, and the Company will have all rights and remedies available under this Agreement or available at law or in equity,all such rights and remedies being cumulative and non-exclusive. 4 flnr.In 7f501 Oh694h9a36ng7ga0ehahfa4573431 arifa37 Upon default by the Company,the Customer must provide the Company with written notice, and the Company will then have 28 days in which to cure or commence the cure of the default. If the Company does not timely cure or commence cure of a default within that 28-day period,then the Customer's exclusive remedy will be to deduct the resulting damages to the Customer from the Total Price. EACH PARTY'S LIABILITY TO THE OTHER UNDER THIS AGREEMENT IS LIMITED TO DIRECT, ACTUAL DAMAGES ONLY. BOTH PARTIES AGREE THAT IN NO EVENT SHALL THE COMPANY BE LIABLE TO THE CUSTOMER FOR CONSEQUENTIAL, INCIDENTAL, PUNITIVE, EXEMPLARY, SPECIAL OR INDIRECT DAMAGES. The Company's liability to the Customer shall not exceed the Total Price, including without limitation, damages to the Home or property during the performance of installation or resulting from the System.Without limiting any of that, the parties clarify that upon termination of this Agreement by the Company for reason of Customer's default, the Company may remove any System materials or equipment from the Home, and submit to credit reporting agencies(credit bureaus)negative credit reports that would be reflected on Customer's credit record. 16. Unforeseen Conditions. The Company is not responsible for failures, delays or expenses related to unanticipated, unusual, or unforeseen conditions at the Home arising out of conditions beyond Company's reasonable control (all of which shall be considered `Force Majeure Events"). Performance times under this Agreement will be considered extended for a period of time equivalent to the time lost due to such conditions. If Company discovers unforeseen conditions requiring additional cost,then Company will present such costs to Customer and get Customer's written approval before beginning or continuing performance. If the Customer does not approve, the Company may terminate this Agreement. 17. Entire Agreement. This Agreement contains the entire agreement between the Customer and the Company relating to the subject matter addressed. No sales representative has the authority to add, delete, or modify the typed terms of this Agreement, either in writing or verbally. 18. Binding Effects/Assignment. This Agreement is binding upon and inures to the benefit of the parties and their respective heirs, legal representatives,successors and assigns.The Customer may not assign its rights or delegate its obligations under this Agreement. Any assignment or delegation by the Customer is void, meaning ineffective. The Company may assign its rights and delegate its duties under this Agreement at any time in the Company's sole discretion. 19. Attorney's Fees. In any action arising out of this Agreement, the prevailing party is entitled to costs and reasonable attorneys'fees from the non-prevailing party. 20. Risk of Loss.All risk of loss or damage to the Solar Equipment will be borne by the Customer from the moment any such Solar Equipment arrives at the Home, unless the loss or damage is caused by the negligent, reckless, or intentional acts of the Company. 21. Counterparts; Signatures. This Agreement may be executed in multiple counterparts, each of which will be deemed an original, and all of which when taken together shall constitute one and the same document and agreement. A copy or electronic transmission of any part of this Agreement, including the signature page, and any electronic signature on this Agreement or electronic copy of this Agreement will have the same force and effect as an original. 22. Indemnification. Both Parties shall indemnify, defend and hold harmless the other and its employees, officers, directors, agents and assigns from any and all third party claims, actions, costs, expenses (including reasonable attorneys' fees and expenses), damages, liabilities, penalties, losses, obligations, demands for injury to persons, including death,or damage to property,to the extent caused by the negligence or willful misconduct of the indemnifying party. 23. Governing Law.To the fullest extent possible,this Agreement will be governed by,and construed and enforced in accordance with,the laws of the state in which the Home is located,without regard to any conflicts of law issues. 24. Dispute Resolution. If the Parties cannot reach a resolution on a matter relating to or arising out of this Agreement,the Parties shall endeavor to reach resolution through good faith direct discussions between the Parties. If the Parties are not able to resolve such matter within thirty(30)days from the date of the first discussion, the Parties shall submit such matter to the following dispute resolution procedures: 5 Mc in. 7f51110h694h9a3Ah979a0ahahf24573431 arifa37 a. If direct discussions pursuant to Section 27 above do not result in resolution of the matter,the Parties shall endeavor to resolve the matter by private, non-binding mediation. To the extent practicable, the mediation shall be convened within thirty (30) days of a party's demand for mediation, and shall conclude within forty-five (45)days of a party's demand for mediation. The cost of mediation shall be shared equally by the Parties. b. If the matter is unresolved after submission of the matter to mediation, the dispute shall be subject to litigation in the Superior Court in Massachusetts serving the area in which the Home is located. The Parties further agree that such the said Superior Court in Massachusetts shall have jurisdiction over each of them, and is the appropriate venue for the determination of such disputes. c. If either party to this Contract shall seek to enforce this Contract,or any duties or obligations arising out of this Contract,against the other party to this Contract, by legal or equitable proceedings,then the prevailing party in such proceedings shall receive, in addition to all other rights and remedies to which such party is entitled, such party's reasonable costs and expenses incurred in such proceedings, including reasonable attorney's fees. For purposes of this Subsection, a prevailing party is defined, to the extent applicable: (1) as a party that is awarded a net fifty-one percent (51%) of its affirmative claims, after any offsets for claim(s) or counterclaim(s) by the other party, and (2) as a party against whom an award of less than fifty percent(50%)of the opposing party's claim is granted 25. Insurance. The Customer agrees to maintain and keep in full force, during the installation of the System and up through and including final payment, property damage insurance that covers the full insurable value of the Home. The Parties hereby discharge and release each other for or on account of any and all claims and liabilities arising out of any loss or damage to any property caused by such risks as are covered by insurance and the Parties shall properly notify their respective insurance carriers that each has waived subrogation rights against the other such that the waiver is binding upon said carrier. 26. State Specific Laws. Attached hereto may be a state specific addendum/notice containing additional terms, conditions, disclosures, and/or notices, specific to the laws of the State in which the Home is located. If attached, the state specific addendum is incorporated into this Agreement by this reference.If anything in the state specific addendum conflicts with these Terms and Conditions, the provisions in the State Specific Addendum will prevail. [End of Terms and Conditions] 6 r)nc ID- 2f501 Ohfi94h9a3fih979anehahfa4573431 arifa37 Notice of Cancellation 05/31 /2023 (Date of Transaction) YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE AGREEMENT, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED.IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE COMPANY AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS AGREEMENT; OR YOU MAY IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE COMPANY REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK.IF YOU DO MAKE THE GOODS AVAILABLE TO THE COMPANY AND THE COMPANY DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE COMPANY,OR IF YOU AGREE TO RETURN THE GOODS TO THE COMPANY AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT.TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO EMPOWER ENERGY SOLUTIONS INC. AT 15 JUNE STREET, SUITE 2A, WOODBRIDGE, CT, 06525, NOT LATER THAN MIDNIGHT OF 06/05 , 20 23 . I HEREBY CANCEL THIS TRANSACTION. CUSTOMER* Signature: Printed Name: Date Signed: 7 nor.In• 2f.5f110h694h9a36h97g ehahfa4573431 arifa37 Notice of Cancellation 05/31 /2023 (Date of Transaction) YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE AGREEMENT, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED.IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE COMPANY AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS AGREEMENT; OR YOU MAY IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE COMPANY REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK.IF YOU DO MAKE THE GOODS AVAILABLE TO THE COMPANY AND THE COMPANY DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE COMPANY,OR IF YOU AGREE TO RETURN THE GOODS TO THE COMPANY AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT.TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO EMPOWER ENERGY SOLUTIONS INC. AT 15 JUNE STREET, SUITE 2A, WOODBRIDGE, CT, 06525, NOT LATER THAN MIDNIGHT OF 06/05 , 20 23 . I HEREBY CANCEL THIS TRANSACTION. CUSTOMER* Signature: Printed Name: Date Signed: R Doc II). 2f5111 nhFi94h9a3Rh979a0PhPhfa4573431 adfa37 Empower Energy Solutions Inc HOMEOWNERS AUTHORIZATION FORM Addendum to Contract I, Jonathan Aronstein (Print Full Legal Name) am the owner of the property located at address: 15 Summer Street Northampton MA 01060 (Print Full Address) I hereby authorize Empower Energy Solutions Inc to act as my Agent for the limited purpose of applying for and obtaining local building, electrical and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. Customer Signature:Electronic Signature Accepted/Addendum to Contract Date: 05/31 /2023 Signature: non Ifl 2f5010hFi94h9a3Rh979a0Phphfa4573431 adfa37 X Dropbox Sign Audit trail Title MA Solar Install Agreement File name MA Solar Install Agreement(1).pdf and 1 other Document ID 2f5010b694b9a36b979a0ebebfa4573431 adfa37 Audit trail date format MM/DD/YYYY Status Signed Document History 05/31 /2023 Sent for signature to Ryan Severin (ryan.s@empowerenergy.co) SENT 14:49:03 UTC and Jonathan Aronstein (jonaron29@gmail.com)from esign@empowerenergy.co IP: 3.140.98.103 05/31 /2023 Viewed by Ryan Severin (ryan.s@empowerenergy.co) VIEWED 14:50:42 UTC IP: 75.135.125.78 05 I 31 /2023 Signed by Ryan Severin (ryan.s@empowerenergy.co) SIGNED 14:51:08 UTC IP: 75.135.125.78 Qo 05/31 /2023 Viewed by Jonathan Aronstein (jonaron29@gmail.com) VIEWED 17:56:59 UTC IP: 71.233.116.40 05/31 /2023 Signed by Jonathan Aronstein (jonaron29@gmail.com) SIGNED 20:06:36 UTC IP: 71.233.116.40 �✓ 05/31 /2023 The document has been completed. COMPLETED 20:06:36 UTC Powered by pt Dropbox S r G CONSULTING �. 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE. PE office(201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com May 30,2023 Empower Energy Solutions 30 Old Kings Highway South#1001 Darien, CT 06820-4551 Re: Engineering Services Moore Residence 15 Summer Street, Northampton, MA 10.940 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing members for the existing roof structure. 2. Design drawings of the proposed system induding a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed 2x6 dimensional lumber at 16"on center. Roof Material: Slate Tile Roof Slopes: 42&45 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing= 7 psf o New Solar Panels and Racking =3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed= 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110%for seismic elements. This analysis indicates that the existing framing members will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Solar Slate installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16"lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2'h", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 21/2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48"on centers. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards and practice,and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V julYYo ,9 s . Scott E.Wyssli , PE , / MA License No. 505 COA#001629764 ,t��or tii S f,i 61;;, . wy? i r, / GS t . A7 �. ' °aNAt EN 1 Wyssling Consulting, PLLC 76 N Meadowbrook Drive,Alpine UT 84004 Massachusetts COA 8001629764 Signed 5/30/2023 LCONSULTING -41—!!i. BREAKER FUSE —�11- BWOCN -- EARTH GROUND INVERTER OUTPUT CURRENT(A). 1 32 1 —--— GEC INVERTER BACKFEED(API 40 _I - MSP RATING(A).] 100 —I EGc 1201240V sINGEL PNASL MAIN BREAKER RATING(A) I 100 uTom cERv�ice w`—u_v-._-MAX BACKFEED(A)*�- 20 / \ - ---_.M___._.__— TIE IN: 1 LST ( METER 063(M14s iii I 11!" , (NIBOLADEC% I lUNt:i N)N BOX i MI BDtAREDdN INVERTER •ROU EED (N)(27)NANWNA O.PEAN DUO D!O AFL•C104 40E 406W PM MOOUltS BE7BOOI4UB -0iTOUNOED 1271 BOLAREDOL PM POWER OPTIMIZERS LINE 910E TAP __. r IN)BOA AC DISCONNECT ^_._... _ _�.�..� •fUSIBIE,LOCKABLE i ' _1���--- 1 _.. .. .._ __._.,/� /t BRANCH OF I. <1 J j ' .oAfUEEE I r „A _-----.-."--:::1— -- f"----—-------- li ---.._./.7-, — J r�z._. _� +T II Ir' i I �r •fa)LOADS !j i ! 1 I I 1 MENU ELEC rROOE 1 • i I I ELEC. LEAD • AWG IA TNWN2 AWO M.TNWN•2 AWG 010.THEMES AWES DID,PV WIRE —�— AWO00.T---EGC/OEC AWG TNY?L2.EGgDEC AWG010 TFAN142.EOCIGEC AWG T-MM3.EGC I SIGN OFF CO . IQAT.34'EMT CONDUIT.Yr EMT CONOUt,3,4-EMT CONDUIT.WC EMT I -__._.--_.__.—.._ ..__.. -..-...._.__.—..__ JOB NUMBER:2020 -- __ Y.NG 'OWNER: DESCRIPTION:M DF9 PAGE __- _—_ _•� MOORE,CHRISTiNA MOORE RESIDENCE HA ` ,� i _____ EAApow RACKING:IRONRIDGEXR-100 UTILITYACCTN:50731.97122 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM €taeF ,v sacuT. ,. MODULES:(27)HA WHAQ.PEAKDUOBLKM.-G10+405 NORTHAMPTON,MA,01060-2230 7.60 kW AC I MS !lc-V.- — DATE: INVERTER:co SOLAREDGE PlVERTER.SE7600H-US(7.60 KW)1 413 210 4800 1 11105E023 I PAGE NAME SINGLE.WE LEGEND 3' S" -7_--7`7"'' 4' 1 M UTILITY METER .� j_� i E'i SCALE: ', �� } ' _ INV INVERTER }- ,. , LAc! AC DISCONNECT \ ji \ IMO MSP MAIN SERVICE PANEL -^,C / gil 7 _ -... O I, .4WS \ \ LB 1 DC JUNCTION BOX r `� `.y === .f5t,..,Ai A P MONITORING UNIT "CI f, I D I DISTRIBUTION PANEL Wyssling Consulting,PLLC 'LC LOAD CENTER l6 N Mendowb.00k Delve,Alpine UT 84004 Mernachusetts(OA 11001614764 Signed 5/30/2023 AT51 AUTOMATIC TRANSFER SWITCH CONDUIT JMER ''''''''% ' 0 ., . 0___.-_„___- FENCE j OWNER: DESCRIPTION: 'osei�leo BY: �PAOE JOB NUMBER:2020 (UTILITY:NG I MOORE,CHRISTINA MOORE RESIDENCE ► _ HA pv2 UTILITY ACCT#:50731-971 1 EM?CV RACKING:IRONRIDGE XR-100 !4 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM ( —MS E AtEt e.r "'" MODULES:(27)I-IANVVHAQ.PEAK DUO BLKML-G104405 1 NORTHAMPTON,MA,01060-2230 7.60 kW AC 11 ,. DATE INVERTER:(1)SOLAREDGE INVERTER SE7600F4US(7.80KVy)1 413 210 4800 1 I 1/032023 1 iPAOENANE. 91TEP N - i ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES INDEX A AMPERE 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED -�— AC ALTERNATING CURRENT DISCONNECTING MEANS MAY BE POWER-CONDITIONING INVERTER. PV1 LCOVER SHEET BLDG BUILDING ENERGIZED IN THE OPEN POSITION,A 2. THIS SYSTEM HAS NO BATTERIES,NO UPS. CONC CONCRETE PV2 SITE PLAN SIGN WILL BE PROVIDED WARNING OF 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY C COMBINER BOX THE HAZARDS PER ART,690.17. GROUNDED. PV3 ( ARRAY DETAIL D DISTRIBUTION PANEL -- DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE PV4 STRUCTURAL VIEWS (E) EXISTING IDENTIFIED BY PHASE AND SYSTEM PER PV5 , SINGLE LINE EMT ELECTRICAL METALLIC TUBING ART.210.5. ------ GALV GALVANIZED 3. A NATIONALLY-RECOGNIZED TESTING VICINITY PV6 ! LABEL SET GEC GROUNDING ELECTRODE CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT GND GROUND IN COMPLIANCE WITH ART.110.3. • HOG HOT DIPPED GALVANIZED 4. CIRCUITS OVER 250V TO GROUND SHALL L"" - I CURRENT COMPLY WITH ART. 250.97,250.92(B) >� ''' ��. Imp CURRENT AT MAX POWER :...umberla(1C� FafmS INVS INVERTERS 5. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC - ,x i Igc SHORT CIRCUIT CURRENT �#. t - - ./c6, kVA KILOVOLT AMPERE RACEWAYS OR ENCLOSURES TO THE , 'r i ivy kW KILOWATT FIRST ACCESSIBLE DC DISCONNECTING , - 4 t.` , A'1 APPLICABLE C DES LBW LOAD BEARING WALL MEANS PER ART.890.31(E). c * 2015 IBC Wyssling Consulting,PLL 1 MIN MINIMUM 6. ALL WIRES SHALL BE PROVIDED WITH * • 2020 NEC 76 N Me+dowbrook W V!,Alpine UT M6w (N) NEW STRAIN RELIEF AT ALL ENTRY INTO BOXES - ��' t M.,wchusem COA E00t6 E764 NEC NATIONAL ELECTRIC CODE AS REQUIRED BY UL LISTING. ", i ,�>-s z -,...�: AHJ; Signed 5/30/2023 MC NOT IN CONTRACT 7. MODULE FRAMES SHALL BE GROUNDED ;" �[@' NTS NOT TO SCALE 11 City of Northampton OC ON CENTER AT THE UL-LISTED LOCATION PROVIDED < "s 212 Main St#1 O0, BY THE MANUFACTURER USING UL LISTED P PANEL BOARD .. Northampton,MA 01060 Pl. PROPERTY LINES GROUNDING HARDWARE. P a - "s." +1 413-587-1240 PV PHOTOVOLTAIC 8. ALL EXPOSED METAL PARTS(MODULE r m PVC POLYVINYL CHLORIDE FRAMES,RAIL,BOXES,ETC.)SHALL BE -' 6 SUBPANEL GROUNDED USING UL LISTED LAY-IN LUGS ,-, �^ UTILITY: NG UL SCH SCHEDULE — LISTED FOR THE PURPOSE.POSTS SHALL <:,. . SS STAINLESS STEEL BE MADE ELECTRICALLY CONTINUOUS SSD SEE STRUCTURAL DIAGRAMS WITH ATTACHED RAIL. ETC STANDARD TESTING CONDITIONS - EMPOWER ENERGY SOLUTION SWH SOLAR WATER HEATER 9. MODULE FRAMES,RAIL,AND POSTS IF .r 30 OLD KINGS HWY S#1001 , DARIEN SHALL BE BONDED WITH EQUIPMENT CT,06820-4551 TYP TYPICAL A UON UNLESS OTHERWISE NOTED GROUND CONDUCTORS AND GROUNDED .,' E6 UPS UNINTERRUPTIBLE POWER SUPPLY AT THE MAIN ELECTRIC PANEL. - (T121' LICENSES ✓ VOLT 10. THE DC GROUNDING ELECTRODE `. 5Um HIC: 198351 Vmp VOLTAGE AT MAX POWER CONDUCTOR SHALL BE SIZED ` ELEC:8209-EL-Al Voc VOLTAGE AT OPEN CIRCUIT ACCORDING TO ART.250.166(8)8 690.47Ill W WATT a I 3R NEMA 3R.RAIN TIGHT `y: I lit Y .. .It ` -- _ — JOB NUMBER:2020 UTILTTY:NG OWNER DESCRIPTION INS °Br: PAGE: ,_.___ MOORE,CHRISTINA MOORE RESIDENCE HA EMpQWEp 'RACKING:IRONRIDGEXR100 UTILITY AcCT e:50731-97122 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM Rrie'B" PV1--- Er:L r c, _;:, MODULES:(27)HANWHAQ.PEAKDUOBLKML-G10►405 NORTHAMPTON,MA,01060-2230 7.60kWAC _ MS REV. DATE: i VERTER 0)samgEDGE INVERTER SE7e0O.4B(7.60 KW) 413 210 4800 +1a12023 PAGE RNA. COVER SHEET 3'1 r__ -� E LEGEND � , , 70 � �_ scAL€. M UTILITY METER . N.:'1 / 1 _...:5:7____--, \-, \ MI _--1 I, +NV INVERTER ► " i AC AC DISCONNECT br-z1„, LiPi MAIN SERVICE PANEL 31 i 1 ' � j i _ J __� i B DC JUNCTION BOX --,, -) , , / 1_3rJ f J A. • P MONITORING UNIT f' 4 ,Eti4/' DISTRIBUTION PANEL rn Wyssling Co uhlng7pitC LC LOAD CENTER {,.,} 'q��,, 76 uN AI Drive,Alpine Lit 84004 0t r Y-.< MaschusettsCOA 4001679754 Signed 5/30/2023 ATS AUTOMATIC TRANSFER 8Vtff TE+t---- ( CONDUIT - - -___ FENCE .1013 NUMBER: UTILITY_NG I EMpt. wE RACKING _ -, - 'CHRISTINA 0E8CRP°" PoDGEXR 100 __ACCr#5p�3�g� MOORE RESIDENCE f°B"ONED°' v.�_ �` ` 5 SUMMER ST — — MODl1ESQ•�Ak�106LKML-G10+40� 10.94 kW DC ROOF SOLAR SYSTEM '— i-EERI -:(1)SOL Ep E _ _____.__._`7 NiORTHAMPTON,MA,01060-2230 7.50 kW AC MS pv2_____SE7600HdJS(7.60 KWj413 210 4800 ,,,---Dore I IR82017 iPAGE 44Mi. 917E PLAN / ,\N LEGEND w{-)-�E ROOF MP2 M P 1 S RAFTERS (9) MODULES (18) MODULES SCALE: r RAIL 13 3' MOUNT --" !k-II ®E OBSTRUCTION ! t' J ' j ____ ____ rTOTAI PENETRATION COUNT I 54 I 5 1 --. �,— ;1 ROOF AREA,Isq,is 1270 — ' _ _ — ----z 1� MODUL ES ARFA,(sq.ft) 571 Fr\.---------- ROOF AREA COVERED BY MODULES(%) 50 MP1 JUNCTION BOX ---...„ j / -- I� ITERPROFILE __ 2X6_ I CONDUIT \��, RSPACING 6' 1 .J,SWAGING— 16• I INVERTER -------__`-.._� L�.(�""- ;t._ `-" - .. 1 TTACHMEN1-- —, SPACING 10• ------." . 1 e l I' 'i I ApRAY PITCH I M•Y 1 _I- r �V AZIMUTH 42• __.� 1 -,,,, - ARRAY er ca I ARRA _._ .---- tIROOF- - 6 .,' �fiYPE SURFACE SLATE TILE �� l� 3`' ��y 1#'f ��.; AFTE_RPR axc _j ba 4 AC DISCONNECT / 1 UTILITY METER ��� f .,'F +, .�E YRTGH } I MAIN SERVICE PANEL -----/ `ruYAI.f1".' °°�� TH ? - ��Wyssling Consulting,PLLC 76 N.4 dowbcook Came,Alpine UT R4004 Massachusetts(OA P0016/9/b4 Signed 5/30/2023 ROOF LEAD SIGN OFF: I OWNER ]=4CRIP10N'. �DESIGNED BY: PAOE'. iJOBNUMBER:2020 U1n�NG _: MOORE,CHRISTINA MOORE RESIDENCE PV3 EM?OWE. RACKING:IRONRIDGEXR-100 UT)UTYAOCT#50731-97122 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM fn E GIG r saLOTioric MODULES:(27)I UVVWHA Q.PEAKDUO BLKML-G10+405 NORTHAMPTON,MA,01060-2230 7.60 kW AC I MS `�-- INVERTER(1)SOLAREDGE INVERTER SE7600H US(7.60 KW)1 413 210 4800 i ' ter`INVERTER: m23 IYAOL NAME. ARRAY DETAN. .---- ,/ lit l'' / SOLAR MODul E - / . ' --..._,,,„,:,____.. ...2 ,LATk 9,,ATE RASHING I ,-;:..2-4-' ,•'' '."-.4 ,•-• .'-<-- / I • „..,..,,,,,,,f-' ----.--7-'-'-' 1 ,,,,,-- ,....--2:•:./ ' ie.. _j stf,TER,eF .STANDOPF ---- 5, Sc.ALF Nis _...., — —.I / ., #filrik" ' MP1 &2 SIDF VIEW . A i RAFTERS. 2X6 @ 16"O.C. , . MAX SPAN- 12.-9" Wyssling Consulting,PLLC 76 N Pileadowbrook Olive,Alpine UT 84004 Massachusetts COA 10001679764 Signed 5/30/2023 __ ._____ . --r-- 1 OWNER DESCRIP,10N IDESIONEO BY. ROE JOB NUMBER:2020 IUT1L1TY:NG , MOORE,CHRISTINA MOORE RESIDENCE ! HA EMpoWEp RACKING:IRONRIDGE XR-100 !LiriLitv ACCT#50731-97t22-1 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM - 11. E Aft RGY t DCUT MODULES:(27)HANWHA OPEN('DUO BLK ML-G10+405 ! NORTHAMPTON,MA,01060-2230 7.60 kW AC IRE,/ MS DATE INVERTER:(1)SOLAREDGE INVERTER SE76001+US(7.80Km' 413 210 4800 1 11E420E3 !PAGE NAME STRUCI ORAL VILW8 _Inv MEANER T62aI- RIDE - - SWITCH -=== " wan GROUND INVERTER OUTPUT CURRENT(A). I 32 I I— — MC ! I INVERTER BACKFEED(A). 40 •-- --._ MSP RATING(A). I 1001 1201240V -, SINGLE PRASE MAIN BREAKER RATING(A). I 100 —I CNPRREAD UTIUTY SERVICE MAX BACKFEEO(A). I 20 F ---7-----'<.—" TIE IN: I LST i / \ ( METER 06308,48 s , I IIIII IN)1 1 (NI SOLADECA I ROLANDO,INVERTER JUNCIKTN DOS •uNruseo 04)(271 HAMM/A CEPEAN DUO ILA AA.•GUN 40E ASSN PI(WODUL 8 •OROUNDED (27)SOLAREDOE P370 POWER OPT EATERS I r— LINE SIDE TAP I 1--- , i RN 0011 AC DRICONNECT A 1 -FUSIBI.F.LOCKAOLE 40A f1.18E8 I - ...1._ 1 4,) i/ /1_811ANGN OF 14 /// 1 .-- - - ----__::- ---.J ', ..._, '_ I 40A I // --- I I BRANCH OP 13 i / I 1 LINE LOAD I I I i f :/ . '‘,/ 1 k• -1-- • 1 :'I \I r---- , . 1 i *1 $ imLoAce ! : )1 1 .2E__•:-_-_-13.-_:.::_-_LJ i _77 GROUND ELECTRODE \NIRE SCHEDULE , . ELEC. LEAD ARO IS THWIN2 MVO W.THWIN2 MSG WO.THVITA2 AWG 010.PV WIRE AWO WE THAWS EGOGEC MO 00.THWN2.COMM AWG RIO.71INVN4.EGCASEC AWG 410.TIENN-2.eac —----I SIGN OFF. .....________.............._________ _ _ _ ...... • CONDUIT.NV EMT CONDUIT,Yr EMT CONDUIT,NW OUT CONDUIT.NC ENT -._____ 4013 NUMBER:2020 UT1LfTY:NG OWNER: - MOORE,CHRISTINA CA-SCRWTION: MOORE RESIDENCE i DESIGNIO BY: I HA PAGE: EN(pOvvEp RACKING:IRONRIDGE XR.-100 UTILITY ACCT#50731-97122:15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM 1/1696/11 MS PV5 MODULES:(27)HANWHA OPEAK DUO BLKML-G10*405 NORTHAMPTON,MA,01060-2230 7.60 kW AC !my, FINVER-rBR:(1)SaAREDGE INVERTER SE703011-US(7.60 KVV) 3 41 210 4800 1 1 1 1/02•2023 IPA%NAME. SINGLE LINE -r— Combiner Box/circuits/Conduit Combiner Combiner Box/circuits/Conduit Combiner SCALE SCALE AC Disconnection/Point Of SCALE DC Disconnect/Breaker/ SCALE Box/Enclosures/EMT Enclosures/Main Service; Box/Enclosures/EMT Enclosures/Main Service 3 Interconnection Iv4•-1'• 4i Recombiner Box ,v4--r.o-.. 1 Disconnect/Breaker PaneUPull Boxes Itf4 1.a" Disconnect/Breaker Panel/Pull Boxes 1 a 1 WARNING /'+ �—PHOTOVOLTAIC SYSTEM EQUIPPED WARNING .1 ddi VY+ARN I N G WARN N V , i WITH RAPID SHUTDOWN ELECTRICAL SHOCK HAZARD EIECTRIyAL HACK—HAZARD TURN OFF PHOTOVOLTAIC AC TURN RAPID SHUTDOWN ! - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE DISCONNECT PRIOR TO SWITCH To THE ENERGIZED IN THE OPEN POSITION TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE OFF"POSITION TO i i os we WORKING INSIDE PANEL i l' '.,�..� ENERGIZED IN THE OPEN POSITION SHUTDOWN PV SYSTEM + L ._._._ . i DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR i AND REDUCE I —r MODULES ARE EXPOSED TO SUNLIGHT SHOCK HAZERD � L] IN THE ARRAY NEC 706.15(C)(4)and NEC 690.13(B) NEC 110.27(C)&OSHA 1910.145(f)(7) ------- NEC 690.13(B)/Roll:596-00879 Roll:596-00878/10-Pk:596-00893 Roll:596-00499/10-Pk:596-00664 IFC 605.11.3.1(1)&690.56(C) 10-Pk:596-00894/Metal 5-Pk:596-00920 Metal 5-Pk:596-00921 Metal 5-Pk:596-00832 Roll:596-00885/10-Pk:596-00888 i DC Disconnect/Breaker/ ,scaLE — __T _.- _ _ — — —�- Breaker/ scALE 7 DC Disconnect/Breaker/ SCALE . SCALE 5DC Disconnect/Bre Recombiner Box u t4•4"-1.0• Recombiner Box 1 -1.0l I Recombiner Box v4•-1.o^; 8 EMT/Conduit Raceways 1/4"-1%0� I PHOTOVOLTAIC RATED AX a FDAERPERA CURRENT MAXIMUM DC VOLAGE SOLAR PV DC CIRCUIT RATED OPERATINGVOLTAGE; MAX D C DISCONNECT i M RATED AC OPERATING vO1.TAGr- � NEC 690.31(0)(2)/Roll:596-00998/10-Pk:596-01006 RATED SHORT CIRCUIT CURRENT: IIIIIIIIIIIIIIIN MAXIMUM SYSTEM VOLTAGE 1.11.1110111111 OF PV SYSTEM PHOTOVOLTAIC POWER SOURCE i NEC 690.13(B) FOR MARKING DC BACKUP SYSTEMS/ NEC 690.53/Roll: 596-01001 / NEC 690.31(0X2)/Roll:596-00999/10-Pk:596-01007 Roll: 596-00238/ 10-Pk: 596-00854 Roil: 596-00240 10-Pk: 596-01009 i I SCALE Inverter!Breaker Panel/Pull Boxes/ SCALE q Production/Net Meter(Bi-directional) I SCALE ENGINEERING STAMP (if appl.) • INVERTER 1/4 i'.0 I 011 .1;.o-1 1 / Main Service Disconnect I„4".,.0 PP > AC disconnect 1BreakerlPoints Of Connection A WARNING THE DISCONNECTION OF THE PHOTOVOLTAIC AC DISCONNECT AWARNING DUAL POWER SOURCE 1 GROUNDED CONDUCTOR(S) RATED AC OUTPUT CURRENT, OIMMIN SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NOMINAL OPERATING AC VOLTAGE miummi ;;a, — — NEC 690.31(E)/ Roll: 596-09323 NEC 690.54/Roll: 596-00892/ NEC 705.12(D)(3)&NEC 690.59!Roll:596-00495 10-Pk: 596-09324/Metal 5-Pk: 596-00924 10-Pk: 596-00882 :'10- • Pk:596-09665/Metal 5-Pk:596-00833 i JOB NUMBER:2020 11TH ITIf NG r°Ninal o�CR1P ON PE5IG en sr: IrAcE MOORS,CHRISTINA MOORS RESIDENCE MS - a P\16 __ ;,,r#2 ,tivE__, RACKINGIRONRIDGEXR.100 UTILITYACCT#50731-9712F 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM MODULES:(27)IIANWHAQ.PEAK DUO BLKML.-G10t405 NORTHAMPTON,MA,01060-2230 7.60 kW AC „E,, DATE- INVERTER:(1)SOLAREDGE INVERTER SE7600FFUS(7.60 KW) 413 210 4800 11/062023 i''^UL NAME "&`S .S -12 AC Disconnect/Breaker/ SCALE AC Disconnect/Breaker/ SCALE ^ Main Service DisconnecU SCALE NOTES: Points of Connection va -,.o' 13' Points of Connection 1`r Utility Meter +ra' t.o"' ANSI Z535.4-2011 Product Safety Signs and Labels,provides I - --- - - ----- !— — I -- • --- guidelines for suitable font sizes,words,colors,symbols,and WARN t f\ A�V I k�V V' T location requirements for labels.NEC 110.21(B)(1) .VY!'1 THIS EQUIPMENT FED BY The label shall be of sufficient durability to withstand the PHOTOVOLTAIC MULTIPLE SOURCES.TOTAL RATING OF ALL OVERCURRENT MAIN PHOVOLTAIC environment involved.NEC 110.21(6)(3) DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED SYSTEM DISCONNECT Adhesive fastened signs may be acceptable if properly AC DISCONNECT AMPACITY OF BUSBAR- - adhered.Vinyl signs shall be weather resistant.IFC 605.11.1.3� i NEC 690.13(B)/Roll: 596-00237/ NEC 705.12(B)(3)(3)/Roll: 596-01000 NEC 690.13(B)/Roll:596-00243 Plaques and Directories at the Service Equipment(MSP) 10-Pk: 596-00853 10-Pk: 596-01008 !10-Pk: 596-00675/Metal 5-Pk: 596-00860 and the Location of All System Disconnects per NEC 705.10&690.56(A)(B)Ro11:558-00350 1 5 Main Service Disconnect „s4F-AL,t1 6 Main Service Disconnect SCALE0.1 7 ENERGY STORAGE SYSTEMS scALE NOMINAL.ESS AC FOLI AGE" i�� Ni ] DO NOT DISCONNECT �� +'\ NOMINAL.ESS DC VOL TAGE IIIIIIIMIIIIM SINGLE 120-VOLT SUPPLY AVAILAHI.E FAULT CURRENT �. �M� DO NOT CONNECT UNDER LOAD 1.1�r ; tt4*,r1�- , !' DERIVED FROM THE ESS: L. t MULTIWIRE BRANCH CIRCUITS DAW CALCULATION PERFORMED: i " ' Q I'I NEC 710.15(C)&692.9(C)/Roll:596-00591! NEC 690.15 (B)&NEC 690.33(D)(2) 1NEC 690.15(B)&NEC 690.33(D)(2) 10-Pk:596-00699/Metal 5-Pk:596-00837 Roll: 596-00244/10-Pk: 596-00671 Roll: 596-00244/10-Pk: 596-00671 Main Service Disconnect ;°";oil 91 20 ENERGY STORAGE SYSTEMS Main Service Disconnect „ '`•o. SCALE ENGINEERING STAMP (if appl.) 18; ,___' _ _____ _ __ .. ,,..�e . r A CAUTION WARNIN � , u ARNING PHOTOVOLTAIC SYSTEM CIRCUIT IS POWER SOURCE OUTPUT • FUEL CELL POWER BACKFEED CONNECTION.DO NOT i SYSTEM L✓ __ RELOCATE THIS CONTAINS ENERGY ' OVERCURRENT DEVICE, la STORAGE DEVICES NEC 705.12(D)&NEC 690.59 Roll: 596-00587/ 10-Pk: 596-00666 NEC 705.12(B)(3)(2)/Roll: 596-00883 NEC 692.56/Roll: 596-01002/ Metal 5-Pk: 596-00834 10-Pk: 596-00884/Metal 5-Pk: 596-00917 10-Pk: 596-01010 - - OWNER J_SLRIP-ION ,DESIGNED BY ',:. JOB NUMBER:2020 UTILITY:NG, -I MOORE,CHRISTINA MOORE RESIDENCE HA ` , F r„�,p E RACKING:IRONRIDGE XR 100 UTILITY ACCT#.50731-97122 15 SUMMER ST 10.94 kW DC ROOF SOLAR SYSTEM MS 7 MODULES:(27)HANWHA Q.PEAK DUO BLK ML-G10+405 NORTHAMPTON,MA,01060-2230 7.60 kW AC L INVERTER:(1)SOLAREDGE INVERTER SE7600H-US(7_60 Kw)' 413 210 4800 1105 3 'PADLNROIL LABELFS I powered by Q.ANTUM /DUO/fi Q. PEAK DUO BLK ML-G10 EUPD PESEA CH r,_,._,,,, u n TOP BRAND PV., r.+aci t 385-410 tim. \ .,,„ ZEIZr ° 2017 ,2018`zort zoio ' ENDURING HIGH PERFORMANCE rommenYR 251 Gol; Warranty 0 CELLS Yield Sacra Ii billa BREAKING THE 2 %EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout 1 boosts module efficiency up to 21.1%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY 0 Q CELLS is the first solar module manufacturer to pass the most comprehen- asive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY i Optimal yields,whatever the weather with excellent . 4k low-light and tem rature behaviour. ENDURING HIG PERFORMANCE 0� Long-term yield rity with Anti LID Technology, Hot-Spot Protect nd Traceable Quality Tra.Q'id. �_'// EXTREME WEAT ER RATING High-tech alumin m alloy frame,certified for high snow(5400 a)and wind loads(4000 Pa). A RELIABLE INVSTMENT Inclusive 25-year oduct warranty and 25-year linear performance warranty'. See da.a"..1'lee!.rx rear'or Luther information. THE IDEAL SOLUTION FOR: Roohce,nays on �- resider tial builtlings Engineered in Germany CELLS I MECHANICAL SPECIFICATION Format 1879mm.1045 ram a 32rmn(including frame) Weight 22.0kg 1.--ICES rum - ar,.am. Front Cover 3.2mm thermally pee-stressed glass with ' anti-reflection technology rar ''' - Back Cover Composite film Frame Black anodised aluminium 4e;,. Cell 6 x 22 monocrystalkne G.ANTUM solar halt Gels 0 Junction box 53-101mm a 32-60 min.1548 mat Protection class IP67.with bypass diodes ,,,,-El Drree Cable 4mm,Solar cable:(4)t1250mm.(-)s1250ram ""a int Connector StAubli MC4;IP68 i r+.wa+Y*oft WALLA) F 32 '''' DETAIL A H N.smw -.=Ieamm ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 ' 395 400 405 410 MiNi MUM PERFORMANCE AT STANDARD TEST CONDITIONS,SIC;(POWER TOLERANCE 1-0'- ) Power at MPP' Pee. [W[ 385 390 395 400 405 410 Short Circuit Current' I,, IN 11.04 11.07 11.10 11.14 11.17 11.20 E - - _ E Open Circuit Voltage' Vr, IA45-19 45.23 45.27 45.30 45.34 45.37 Current at MPP lee (A) 10.59 10.65 10.71 10.77 10.83 10.89 Voltage at MPP Vra, [V) 36.3E 36.62 36.88 37.13 37.39 37.64 Efficiency, q [%J a19.6 t19.9 t20.1 a20.4 a20.6 20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT" Power et MPP Pr,,,,o PM 288.8 292.6 296.3 300.1 303.8 307.6 8 Short Circuit Current 14, IA) 8.90 8.92 8.95 8.97 9.00 9.03 Open Circuit Voltage V,n [VI 42.62 42.65 42.69 42.72 42.76 42.79 Current at MPP tin IA] 8.35 8.41 8.46 8.51 8.57 8.62 Voltage at MPP Vu„a [VI 34.59 34.81 35.03 35.25 35.46 35.68 'Measurement tolerances P,±3%;I;,;;V,t5%at STC 1000W/m=,25x2•C,AM 1.5 according;o IEC 60904-3 0W/m',NMOT.spectrum AV 1.5 0 CELLS PERFORMANCE WARRANTY - PERFORMAN«:AT LOW IRRADIANCE ,.,... -- ;uo o>4 -.a.,.-a,�r,ad ..-....r At least 98%of nominal power dun- i - . u% ire tusi year."thereafter max.0.5% u wQ . degradaucn per year.At least 935% raa _ ----...__.. • of nominal power up to 10 years At least 86 b of nominal power-;:p to g I '^ 25yems '°�---- --- T 1 Al dots within measurement toter • - _ antes.Ful warranties an accordance 8 with the warranty terms of Me 1ee ' '...~-'-- ISO--WO -- 1eee 3 „ 0CEULS sales organisation ofyou IRRADIANCEty:imt a s a a respective country a.. ffi to ve.,oq Typical module nce under low lrradance conditions in comparison toST amdtions(25*C,1000W/m't. a TEMPERATURE COEFFICIENTS { 1 _.__....a.._.....[%/K)'-`-----. *0.04 TernperatureCoeff.c-, tofV 9_'_ (%%/KJ..........._t_027 0 Temperature Coefficient of P;,y y E%/K) -0.34 Nominal Module Op,atirtg Temperature NMOT rCI �,, 43±3 0 I o PROPERTIES FOR SYSTEM DESIG 0. - Maximum System Voltage V,,.,, ' (VI i 1.000 PV module classifies on Class II Maximum Reverse Current I., [Al 20 Fire Rating based on,NSI;Lit.€1730 C STYPE 2 I"_____ Max,Design Load,Push(Pull [Pa) 3600/2660 Permitted Module Te.rperature -40.Cf+85'C m on Continuous Duty o Max.Test Load.Push/Pull Epe) 5400/4000 0 QUALIFICATIONS AND CERTIFICATES PACKA LNG INFORMATION a QualityCant10164 PV-TUN Rheinlenrk -�. Ell -....__ i Ec atus:mzs:tEc stric:z ue #.., this dale shaetcamisfits - - with GIN Era 50380. 1e41AiY"' r'tcrizortal 1940rrm 1100rtvn 1220mm �751kg 28 pallets 24 pallets 32 modules QCPV Certificationongniny. packaging _ Cerebration PS79r: a ninan •.'-..'--•.. E Menwhe 0 CELLS GmtH F Note:Installation instructions must be followed.See the installation end operating manual or contact our technical servo•e department for further information on approved ins Lion end G use of Intl product. Made In Korea 8 Henwhe 0 CELLS AustreRa Pty Ltdtre gp Suite 1.Level 1,15 Blue Set.North Sydney.NSW 2060,Australia I T£l+61(0)2 9016 3033I FAX 4611(0)2 9016 3032 1 EMAIL¢cols-eust•aTtals�¢ lls q- ce .com I WEB www. cells tom/au I Engineered in Germany GI CLLS Single Phase Inverter MINIM With HD-Wave Technology for North America Single Phase Inverter SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ with HD-Wave Technology 1 SE7600H-US/SE10000H-US/SE11400H-US mMODEL NUMBER SE3000H-US SE 380011-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US for North America T APPLICABLE TO SEXXXXH-XXXXXBXX4 N WITH PART NUMBER SE3000H-US/SE3800H-US/ SE5000H-US/SE6000H-US/ OUTPUT SE7600H US/SE10000H US/SE11400H US _ ":" "Y 30,.. 339 9 1 moo mono j tw622 i t "- m Mvbnu n AC Power OuKtn 33800 W 240V fiCWP&2 tGA 7�p : WOW T„ _2„p1 I VA 3.300 0 208V 5000 r 238V ) h1(IIO @ bi94 I 72-25 Ar,GM put VoBage AT Nom eAa. i J _ 1 _-i r__ 4-_ l VS 2n_2a-z6a) EE 1 I 1 p `( AC C:utpt4 Vplbge Min Nwt•1Aaz 1 - - - 1 - 1 1 183-48-229) 1 i 1 1 AC Frats.iot.?(Nominal) s93 60.50.5n 1 I+i A 0 Minimum COnbrotxn Output itt.5 15 21 ,t _ 32 f 1.2 . 6 47.5 i A MmC.,nimuant:2CMnOu_tOan._-___.t— _ __ — ,-�- . __ ...- _. ___ ` .'-_-48_.5:_A- Curren, 10 �� 4 0 G EOPk•Imocof 1 Adjustable-0.85 to 0.05 O O we!Meaow 1 _._A wary Monitoring MAowtg Prote:o:n, _.-__________ Country Configurable Thres14.1. �_-K. . INPUT yau,r ,^,' -.1:('1i >t r4... .._!i rin Atatum VC P;..1pr•24_OV_^.......__ E50._._._- 5900 P50 —_ . 9500 .11800 15 00 650 i W O ® • 0 Manrnum a Row 4298'V 51u0 -1C -`.� -`---1 ssw 1 W . - M sarxromtcnkss UrAir.-naeU� —'--•._.._..____._..T_ _•' —..__._-- __... _ 0 x0 Alminum 111(utV t,Y1r. _.. ``` ._- —r---__-_._______ j VS: Nominal Ix.Input loll V._}-_.—.._...._.._—_._. 3� -- 400 O • Minmum Input r rr®240V` 85 1C.5 r-1-5 ^� ,,is '0 27 YJ.S Adc_ MaximumInput Current ra708V -.---- o _._._.� - .__1 5 4_—_— .--'--. 227 Aar. May,Input Snort cua Current�_____—._-__ ._.._.___._...__..____.—._— at AtK F,ovrso-Poln I Plot1O0 t ros I • r - - wz w M-ratA Isolation ttroction 6wtn Sensitivity ______ _. __ AUnmum Inverter ElEuemY i 99 ! 99? ?°;3 2Y V CEC Weighted ER.Mncy 99 i208v ' 75 Nly httaho Now Comm.". ,25 -___.....-_-_..___._�..__-_— W Optimized installation with HD-Wave technology --_ h A n:)M.imr9 M•x c ma,M'ir.c4 mr n'xttf v,E lima nt.e.i,.M M•war.nm,r I Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small,lightweight,and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in consumption metering(1%accuracy)and production revenue grade / Integrated arc fault protection and rapid metering(0.5%accuracy,ANSI C12.20) shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 solaredge.com solar J • z Single Phase Inverter With HD-Wave Technology for North America SE3000H—US/SE3800H—US/SE5000H—US/SE6000H—US/ SE7600H—US/SE10000H—US/SE11400H—US MODEL NUMBER SE3000H-US SE3800H US SES000H-US SE600011-US SE7600H-US SE10000H-US 5E11400H-US ADDITIONAL FEATURES RS43,£ttsrnet;.98an(opt,,,a, ,•IFda oos�c-r _..._.. ___,._......_..__ .v_. Revenue.:made AE;( 1 ANSI ,_. C1 0 " I Uphona _—. Coo trtt h7n metering ___ _... Inverter Ctiwmhslavn9 WMPM dw S-tApp mark u Built-in sing Built- Wrh Anew;Rant f_Lv.i C.00010sm —__Rapid Silldsio.-NEC 2014 and _. .__ a..mirk Ry I 2017 690.12 ,�_ -q ul.ss Sbutslom,utxr,AC GtrJ JixsPxw;r T____ ___-_..._. STANDARD COMPLIANCE • Safety 111 li4i.ULi tO1 SA.tn.I6998.CSA C22.[.Canadian MCI exording re 11l1.IN.07 i. ;Ad Connnchon Standards 1tEE1S47,s.ia 21,Rote 14 MB ' FmOSSIOM FCC Piet IS Clsss 9 I INSTALLATION SPECIFICATIONS AC cart[t COrsd i S le Tar .I.__.».__..:..._. I Mas'xma m Nfi AWG ,i a+ arn,04-4 Aw$ (X.'Inne C7ndult Size.e d S_,ngs,'I ..-�._�.,,• .__... 1 1Aatirnurn r -pnn�,/146 4WG ry t•M2cmlY�/1 T Anngt/14 6 ANG ._.. ANG Rank ,. Crruu:ons with Safety aen I—_.______.__ - __ in dY�s" s-7r14.6z6.8;450A 310R771 i 21.3.r146 r 7.3 C540%3:u 4185 !NvWa01 _ _ TM' Wnc.2ht.Min 5a1Bty rwi4h -_-_-�+--_-_~�22/10 1}__51/114 } N :62/11.g��^ I 389/170 jRl/tQ NNW n22S __ __NY! dA.AY Cuslsy ._..____...^.- N•tw+i Cw+rRsenn - j 0{wranng knitmranrte parv3R_._.._._�______.�._.—__._.._._. •r40 m of F11^h'to.Ns° �._ r C_. Prprecti n R4tmg.+� NSW A 4%drh4na rRh Sa(ery Switch) .b000rrwh Ro.eru*Cnce 4 en. StmOrOS CONC4.Awn eeh R,00;G,&Drd iry46CCnyrr(ionikcc,PMT•1SI.mWIKJtoP1 ill to..nwrt{A'ri m,o,,, orm Y' :r,s4Trtv,t q.HN w n,k:e,t saw 04.SLA00750-2CONA-2D t+.A T0l9J-A"rh1A-.'0.':'.M:ar tw .rW Iwwe nPwa es:AA''i22't.-or rows de...Slx*nrmor anonroltf-.+.Ww-ncdaledm ceN'.rtei/dctoRt flecise-kmpwWRdnnoq-roe.r p't How to Enable Consumption Monitoring 0y simply wring current Ilaluformers nvough the IneerterI c.sblsg AC tor Owls and connecting them to the service oarsvl homeowners vd8 gain full insight into their nousehold energy usage Peiping them to avoid high electricity Ms Single phase inverter with HD-wave technology and built-in ROM and Service Panelconsumption monitoring Grid Ell CT L7 N12 Lidded CA13e table LI S iE u r rrr l EEEEE#E:rom o twMr■Ec�rrrlra� K conduit CI,ol.00t.FMAcg...Rc Nn>.,..,w.w sa(ARtncE aw sa,n4sr ic.,eels.ens.e+suuuea.amtwe run.a•.v.wai..o.n,.:.ersd«ram...gas,Inc a RoitlS we,ex.,...,ee met 1.e,e,Ae o.n.v..yr w„e s :cnuum)v o )Atte,oner:w.sn,Ihc.vu.sw..r a o..v.11.0..,,,e Power Optimizer O For Residential Installations S440 / S500 / S500B / S650B • 25 YEAR WARRANTY 7' Q N m Enabling PV power optimization at the module level I Specifically designed to work with SolarEdge / Mitigates all types of module mismatch loss,from residential inverters manufacturing tolerance to partial shading / Detects abnormal PV connector behavior, / Faster installations with simplified cable preventing potential safety issues* management and easy assembly using a single bolt / Module-level voltage shutdown for installer / Flexible system design for maximum space and firefighter safety utilization I Superior efficiency(99.5%) / Compatible with bifacial PV modules Functionality subject to wrveter model and 6rewae venron solaredge.com solar e s �' Power Optimizer For Residential Installations S440 / S500 / S500B / S650B S440 S500 55008 S650B UNIT INPUT Rated hput JC Power' 440 I ',1-1 650 W Absolute Maximum Input Voltage(Voc) 60 :, 85 Vdc MPPT Operating Range 8-60 1,,S—'CS 12.5-85 Vdc Maximum Short Circuit Current(Isc)of Connected PV Module 14.5 I 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category If OUTPUT DURING OPERTION Maximurrn Output Curren; 15 Mc Maximum Output Voltage 60 I 8'' Vd: OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) ',a, i U.,tr.u:.'oltaya oil f„aar Opbnli<:r I ' s L 1 1 Vcc STANDARD COMPLIANCEM EMC FCC Part 15 Class B,IEC61000-6 ,IEC61000-6-3,CISPR N-SC. • Safety IEC62109-1(class II safety),UL1741 Material UL94 V-0,V Resistant RoHS les Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vac Dimensions(W x L x H) 20 x 155 x 30 129 x 165 x 45 mm Weight 720 790 9' Input Connector M 240, Input Wire Length 0.1 (- Output Connector MAC4 Output Wire:-engdt (-)2.3,(-)0.10 rn Operating Temperature Range' -40 o+85 °C Protection Rating IP68 Relative humidity 0-100 % (1)Rated power of the:nodule at STC will n t exceed the Power Optimizer Rated Input DC Power.Mobiles Nth Op to.5%power tolerance are allowed. (2',For details about CE compliance,see Pexfaration of Confirantsitj—Cr. (3,For otie'connects types please contact SolarEdge )earn, e-rahey is hooked for ambient ternperarures above+85'C for S440 aid 5500,and to-amber*.•errex-natures atxw-75(for F ElO6 Feder to be Fig_Ot'„ ',< .....umait.re De-Rating Te-tvtir3l Nome for details. PV System Design Using a SolarEdge SolarEdge Home SolarEdge Home Three Phase for Three Phase for Inverter' Wave Inverter Short String Inverter 230/400V Grid 277/480V Grid Single Phase Three Phase Mir:nAril St,rig Length 5440,5500 8 16 "8 Gower Optimizers) S500B,56508 6 8 14 Maximum String Length(Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when'be power difference between sir ings See' Seer' "3500 15000 W is less(ban 2,000w) , Parallel Strings of Different Lengths or Orientations Yes (5)It is not allowed to ma S-series and P-series Power Optimizers in rare istakliau- (6.)If the inverer's rated AC power s manrnen nominal power per string,then t'er mac:morn(YAWN per strrg oil be able Sc teach no 10 the roan is rnaei'txrr;enp-un DC prowl Refer to pooJcatiott Note-Single Strirxi Drrngn G eletnes. S440, S500(Flat Bracket) S500B, S6508(Bent Bracket) r --- 14.1-.y. ) El P 1, a 0 1{ t Rut 1° r ' , 'Ear a .ems-s,- ff� - .._.-. Bz w ei SolarEdge Technoiogies Led.At rights reserved.SOIAPLDGE,the SolarEdge logo.OP'1MIZED BY SOIARmJ are trademarks or registered andeenark of Sotar[dge Technologies.Inn. E E RoHS All other trademarks mentioned herein aye trademarks of their respective owners.Date:February 162073 DS-00009.1-FNG.Sobjec;to change without notice flit IRON RIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes.Each size supports specific design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match. Solar is Not Always bunny Over their lifetime,solar panels experience countless _ extreme weather events.Not just the worst storms in years, - -. but the worst storms in 40 years.High winds capable of - "'""'�+-gip •-, ripping panelsc from a reef,and snowfalls weighing enough to buckle a panel frame. } XR Rails are the structural backbone preventing A ,, {{ !IlL. 1r"""�+ these results.They resist uplift,protect z - %R10 XR100 XR1000 � against buckling and safely and efficiently ;" )(Rio a.desk,low•protde mounerg xxnw is the ultimate residential /41000 a a heavyweight a0000 transfer loads into the building structure µ' rail designed for regions with light or mounting rail n supports a rang.of solar mounting fells 11 a buh to handle Their superior spanning capability n c...e sp.na up to s leaf. wend anal snow conditi conditions who also lent 0 a fl,mat«,ides.wen.nn dc.to while remaining light and economical. maatrnueg spans up to 10 feet. feet for sentential applications. requires fewer roof attachments, ? l reducing the number of roof .. ti : • • t, pan r>4 pawury • l0'spanning capability • 12 spanning capability and the amount • Pi me t load.apebihty • Heavy bed capet:hly • Extremes load capability penetrations "'+., 't s t • Clem S black anodized hash • Char 8 deck endued Irmo • Clear aniline finish of installation time, , w • • i•vo,,oi spices avoloole • Internal spices avaaeme • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.'Values are based on the following criteria:ASCE 7-16,Gable Roof Flush Mount,Roof Zones I&2e.Exposure B,Roof } `3 Slope of 8 to 20 degrees and Moan Building Height of 30 ft.Visit IronRidge.com for detailed certification letters. ¢ s ESP .ii".*3'SFt W��1 tAsh t a 4 t 6 ti Force-Stabilizing Curve Shoed roots generate both vedicel and lateral s„.,, q 9k, x �� tercel,on mounting reds which can calves them • p, e 3s `- twat TN curved shape of XR Asia � •^M 1 p400500.00 is Nodally&Brad l.. .reaw strength in both ... .. ) `dc�45S�. '�-. ' >*�``- directions while lot Ming the tetsting.TIES unhand teaxe ensures 0teiier security during ush enro __ __ % i .,• :-k i weather and a longat ystem I reams. j. t10 «,,..., �' 3� a a� t 1 v.120 p. r : sue-s-- s '- -- I� 1a0 -' r ten f. F •€4 Compatible with Flat a Pitched Roofs Corrosion-Rssistant Materialsi i e 80 �. *"y,, - 4 %R Rate o s --4onRape o1Ms I All no Reds err ale of 6000-lanes ♦ y '.-R ; i rnmpot,de wind nary.of he IN I anti i S than oroteneC with an I T8a . �N� vz 1u,? ... Fbsr ohot end opions for flat , i anal ed finish-Anodizing prevents surface 2 i..'.._ an r fi•'v'M'•" `a. other.vans root -+roe,rocns. are eaudurmua appe rwhb also prevaing 80 too s -Sn2a«P _ d ,. -_.._.._...�..__ wr 4.sc� ',,°� ry eke-ee.mra..sasro�.r ilea :,nmde"uaare-,•k. s ._.,,aid;;Irvne.•;z. _ .. _ SOLAR SLATE Product Design and Specifications: Slated for Solar sm -+} f Top View. Dimensions: 17.2"x 7.4" Side View. Dimensions: .07" 1 Parts List: 2 y,y ; 1-5.5" Lag Bolt 2-Stainless Washer 3 3-Solar Slate Plate Flashing 4-Plate Spacer 4 5-Tube Spacer r. 5 Manufacturer Solar Slate Solutions Model Name SSP002 Product Length(in) 17.20" Product Width(in) 7.40" Product Height(in) 0.51" Solar Slate Solutions Product Thickness(in) 0.070" 77 Alexander Road,Suite 14 Material Proprietary Modified Copolymer Billerica,MA 01821 Product Weight(oz) 5.655 oz. info@solarslatesolutions.com Fire Rating UL 94 HB Heat/Cold Fluctuations -25F—140F Country of Origin U.S.A.