Loading...
12C-023 (4) BP-2023-0596 22 BURNCOLT RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 12C-023-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING P RMIT Permit# BP-2023-0596 PERMISSION IS HEREBY GRANTED TO: Project# 2023 SOLAR Contractor: License: Est. Cost: 28797 POSIGEN DEVELOP R LLC 071546 Const.Class: Exp.Date: 11/19/202 Use Group: Owner: MASL WSKI JANET K Lot Size (sq.ft.) Zoning: RI/WSP Applicant: POSIGEN DEVELOPER LLC Applicant Address Phone: Insurance: 189 SPRUCE ST (978)660-8505 4087447245 LEOMINSTER, MA 01453 ISSUED ON: 05/08/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 20 PANEL 8.0 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I • V • >2 . Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Commonwealth of Massac us ,5-4-0 Board of Building Regulations an Sta , Massachusetts State Building Code,-780 '. '., �0 CffPALITY `. _ SE Building Permit Application To Construct,Repair,Renovate 1 . a Rev,ed Mar 2011 One-or Two-Family Dwelling o, GNS This Section For Official Use Only Building P it Number: A,0'/1') • 9 Date Applied: Ew,�s Koss ��v S-9 22Z3 Building Official(Print Name) Signature Date SECTION 1:STTE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 22 Burncolt Road Florence MA 01062 12C-023-001 1.la Is this an accepted street?yes X no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,154) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Janet K Maslowski Florence MA 01062 Name(Print) City,State,ZIP 22 Burncolt Road (413)335-3690 jkmaslowski@comcast.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.0 Number of Units Otherx❑ Specify. Solar Brief Description of Proposed Work2: PV Solar Panel Roof Mounted Installation 20 Modules 8.0 kW SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated COS' Official Use Only (Labor and Materials) 1.Building $ 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ 0 Standard City/Town Application Fee ❑Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Suppression) Total All Fees: $ Check No._ra., Check Amount: Cash Amount: 6.Total Project Cost: $ 28,797.60 ❑Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-071546 11/19/2023 Stephen Spengler License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 184 Edge Hill Rd. No.and Street Type Description Milton,MA 02186 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 617-293-2743 mapermits@posigen.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 05094 04/19/2024 PosiGen Developer LLC 2 HIC tegistration Number Expiration Date HIC Company Name or HIC Registrant Name 50 HOWE AVE mapermits@posigen.com No.and Street Email address MILLBURY,MA 01527 (504)233-0617 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes DX No D SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Michael Makar 7r1aA .4, 4/18/23 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will rLot have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"maybe substituted for`Total Project Cost' City of Northampton . " S • SI � Massachusetts s c �� at, c ( s is y p* DEPARTMENT OF BUILDING INSPECTIONS 1 ♦" r 212 Main Street • Municipal Building 0� at r`IrfNorthampton, MA 01060 sbh, arpv` CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: 50 HOWE AVE MILLBURY, MA 01527 The debris will be transported by: Name of Hauler: PosiGen Developer LLC Signature of Applicant: 7 , 14I Waiait, Date: 4/18/23 _ '\ The Commonwealth of Massachusetts 1!_*,: _ ,J, Department of Industrial Accidents C _-e1= 1 Congress Street, Suite 100 *= Boston,MA 02114-2017 ' ��� www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): PosiGen Developer LLC Address: 50 HOWE AVE City/State/Zip: MILLBURY MA 01527 Phone#: 225-335-1845 Are you an employer?Check the appropriate box: Type of project(required): xl.❑I am a employer with 700 employees(full and/or part-time).* 7. El New construction 2.0 1 am a sole proprietor or partnership and have no employees working for me in 8. 0 Remodeling any capacity.[No workers'comp.insurance required.] 3.0 I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. El Demolition 10 Q Building addition 4.0 I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.❑Roof repairs These sub-contractors have employees and have workers'comp.insurance.: x 14.Ei Other Solar 6.❑We area corporation and its officers have exercised their right of exemption per MGL c. 152,§1(4),and we have no employees.[No workers'comp.insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. +Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Crum&Forster Indemnity Company Policy#or Self-ins.Lic.#: 4087447245 Expiration Date: 03/01/2024 Job Site Address: 22 Burncolt Road City/State/Zip: Florence MA 01062 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct Signature:)/iZu k(.a4 a. Date: 4/18/23 Phone#: 504-233-0617 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: VWSSLING ONSULTING «•�—-� 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com March 2, 2023 Revised April 27,2023 Posigen Solar 280 Moody Street Ludlow, MA 01056 Re: Engineering Services Maslowski Residence 22 Burncolt Road, Florence MA 8.000 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x6 dimensional lumber at 16"on center. Roof Material: Composite Asphalt Shingles Roof Slope: 27 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2of2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ecofasten installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a#12 lag screw is 176 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on two screws with a minimum penetration depth of 2 '/z ", the allowable capacity per connection is greater than the design withdrawal force(demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two#12 lag screws with a minimum of 2 '/z"embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48"on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve ruly yours, -P� dlp Scott E.Wyssli , PE MA License No. 5050 MA COA No. 0016297 # • i.'" Sc• i WY I �r , '. • IL No 5O co • /r T2 ‘2(''(; 0 Q ‘ A'FA, i.$ ' y \\..‘ Wyssling Consulting, PLLC 76 N Meadowbrook Drive,Alpine UT 84004 Massachusetts COA 8001629764 Signed 4/27/2023 NATIONS ELECTRICAL NOTES AERIAL VIEW VICINITY VIEW AMPERE 1. WHERE ALL TERMINALS OF THE ALTERNATE CURRENT DISCONNECTING MEANS MAY BE .,r BUILDING. ENERGIZED IN THE OPEN POSITION,A CONCRETE SIGN WILL BE PROVIDED WARNING OF COMBINER BOX THE HAZARDS PER ART.690.17. 1 DISTRIBUTION PANEL 2. EACH UNGROUNDED CONDUCTOR OF DIRECT CURRENT THE MULTIWIRE BRANCH CIRCUIT WILL EQUIPMENT GROUNDING CONDUCTOR BE IDENTIFIED BY PHASE AND SYSTEM . I - , EXISTING PER ART.210.5. ; us'-� ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING 4 w -_ • GALVANIZED LABORATORY SHALL LIST ALL ,,,. GROUNDING ELECTRODE CONDUCTOR EQUIPMENT IN COMPLIANCE WITH ART. ' 110.3. • { GROUND 4. CIRCUITS OVER 250V TO GROUND ---- -.. HOT DIPPED GALVANIZED SHALL COMPLY WITH NEC.250.97, CURRENT 250.92(B) )- R -, CURRENT AT MAX POWER 5. DC CONDUCTORS EITHER DO NOT - -_ INVERTERS ENTER BUILDING OR ARE RUN IN A METALLIC RACEWAYS OR SHORT CIRCUIT CURRENT Rd ENCLOSURES TO THE FIRST ((1fC.0 t KILOVOLT AMPERE ACCESSIBLE DC DISCONNECTING x`` B` { t o k4 t • - KILOWATT MEANS PER NEC.690.31(E). LOAD BEARING WALL 6. ALL WIRES SHALL BE PROVIDED WITH MINIMUM STRAIN RELIEF AT ALL ENTRY INTO NEW BOXES AS REQUIRED BY UL LISTING. NATIONAL ELECTRIC CODE 7. MODULE FRAMES SHALL BE NOT IN CONTRACT GROUNDED AT THE UL-LISTED APPLICABLE CODE INDEX NOT TO SCALE LOCATION PROVIDED BY THE INTERNATIONAL BUILDING CODE 2015 ON CENTER MANUFACTURER USING UL LISTED INTERNATIONAL FIRE CODE 2015 PANEL BOARD GROUNDING HARDWARE. INTERNATIONAL RESIDENTIAL CODE 2015 PV-1 COVER SHEET PROPERTY LINES 8. ALL EXPOSED METAL PARTS(MODULE INTERNATIONAL ENERGY CODE 2018 PV-2 SITE PLAN PHOTOVOLTAIC FRAMES,BOXES,ETC.)SHALL BE NATIONAL ELECTRIC CODE 2017 GROUNDED USING UL LISTED LAY-IN PV-3 ATTACHMENT PLAN POLYVINYL CHLORIDE LUGS LISTED FOR THE PURPOSE. PV-4 ATTACHMENT DETAIL SUBPANEL 9. MODULE FRAMES AND POSTS SHALL SCHEDULE BE ELECTRICALLY CONTINUOUS WITH AHJ: HAMPSHIRE COUNTY PV-5 THREE-LINE DIAGRAM STAINLESS STEEL ATTACHED RAIL. PV-5.1 ELECTRICAL NOTES SEE STRUCTURAL DIAGRAMS 10. THE DC GROUNDING ELECTRODE UTILITY: NATIONAL GRID STANDARD TESTING CONDITIONS CONDUCTOR SHALL BE SIZED PV-6 PLACARD SOLAR WATER HEATER ACCORDING TO NEC.250.166(B)8 GENERAL NOTES PV-7 SAFETY LABELS TYPICAL 890.47, 1. THIS SYSTEM IS GRID-INTERTIED VIA A BILL OF MATERIAL UNLESS OTHERWISE NOTED UL-LISTED MODULE DATASHEET UNINTERRUPTIBLE POWER SUPPLY POWER-CONDITIONING INVERTER. VOLT 2. THIS SYSTEM HAS NO BATTERIES,NO UPS. INVERTER DATASHEET VOLTAGE AT MAX POWER 3. ALL INVERTERS AND ARRAYS ARE OPTIMIZER DATASHEET VOLTAGE AT OPEN CIRCUIT NEGATIVELY GROUNDED. NEMA 3R,RAIN TIGHT 4. SOLAR MOUNTING FRAMES ARE TO BE MOUNTING SY �l:M DATASHEET WATT GROUNDED. a CO Ti P CON TOR DATASHEET POINT OF INTERCONNECTION TOTAL ROOF AREA: 1638.12 sq.ft M 1 gd r ,lac;: �,�ENGINEERING NGINEERING LETTER TOTAL AREA COVERED BY ARRAY(%):26.06 UL a{;y�ygROUIJ •NDING CERTIFICATION pos I G e n JOB NUMBER: P-007446 OWNER: DESCRIPTION: $.' JANET K MASLOWSKI, PV-1 r 0 JANET K MASLOWSKI ,, RESIDENCE , orgy Efficiency•Roofing UTILITY: NATIONAL GRID 22 BURNCOLT ROAD DC SIZE:8.00 kW , `,' ,/�Qy• PAGE NAME: 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS FLORENCE MA 01062 AC SIZE:7.60 kW eti','� COVER SHEET 280 Moody St., ANNUAL PRODUCTION:8,007 kWH idlow,MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 sCA wyssling Consulting,MC NTS: LICENSES UTILITY CUSTOMER'S NAME:JANET MASLOWSKI 76 N Meadowbrook Drive.Alpine UT MOODATE: LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 Massachusetts COA a001629764 C.#100105-EL-MR INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANA REV: Signed 4/27/2023 3 30 2023 N ARRAY AREA NOTE: 6 INCHES GAP BETWEEN LEGEND: „� ARRAY ROOF Roo, TOTALSHINGLES&TOP OF PANELS. ROOF ROOF TYPE MODULES ARFt AREA MEA COVERED COVERED BY (SQ.FL) (Sq.FI.) BY ARitAY l%1 ARRAY%) (E)UTILITY METER E ., NIiLE 2 42.89 1838.12 2.81 wig 02 ASPHALT 234.78 1538.12 14.33 MSP (E)MAIN SERVICE PANEL ASRHALT 26.08 MJ SHINGL.I; 4 85.38 1838.12 5.21 ASPHALT 3 64AJ $3e.12 3.61 SP (N)SERVICE PANEL $HIND E ' AC AC DISCONNECT 0 0 I INV I INVERTER JB JUNCTION BOX ° O OBSTRUCTION 400 j MODULE /A LJ M r,) Ac r: / STRING'S A / STRING#1 -10 MODULE �/////f INV STRING#2-10 MODULE * ( 4D //4 Bj �/l ROOF SECTION(S): 7/ / 1Q SLOPE: 27 MODULE: 2 AZIMUTH: 355 �2 SLOPE: MODULE: 11 AZIMUTH: 175 ®SLOPE: 27 FOH MODUL' 4 0M 4, 265 BURNCOLT RD ' o, ' 27 JOB NUMBER: P-007446 OWNER: DESCRIPTION: 85 •,,��:`' 01,'; ` / os i G e n JANET K MASLOWSKI JANET K MASLOWSKI, : , P V-2"O UTILITY: NATIONAL GRID 22 BURNCOLT ROAD RESIDENCE �, ,. : ,s /�/� ergy Efficiency•Roofing DC SIZE:8.00 kW ���`�� PAGE NAME: 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS FLORENCE MA 01062 AC SIZE:7.60 kW -^�E- PLOT/SITE PLAN 280 Moody St., ANNUAL PRODUCTION:8,007 kWH idlow,MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 sling Consulting,PLLC SCALE. ( 74 N eadowbrook Drive,Alpine UT 04001 3/16"=1'-0" LICENSES UTILITY CUSTOMER'S NAME:JANET MASLOWSKI Massachusetts COAI001629764 LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 Signed 4/27/2023 DATE: C.#100105-EL-MR INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANA REV: 3 30/2023 AY#1 LEGEND ARRAY#2 ROOF • ATTACHMENT O COUPLINGS 0 OBSTRUCTION —- RAFTER i- � ' I i . 1 � 111 I I i i • ' ` f — ! i ? 7 • • I 1 1 1 1 i 11 1 1 I 1 I 1 1 I I I I I I I TOTAL PENETRATION COUNT:50 1. 1 II I I II1111 1 1 1 1 1 I I I I I I I ARRAY#1 y J IRAFTER PROFILE 2'X 6" I I I I 14' 6 + 1 1 + 1 T 1 y 1 1-1— . I RAFTER SPACING 16'0C I I I • I '., I I I I I I I I I 11 I I I I I ROOF PITCH 27° I I I d 1 I I ' I ' 11 1 I I I I I I ARRAY PITCH ZA ROOF AZIMUTH 355° -•-6'-11"----1-- 42-8" — 1 I LIIIII ARRAY AZIMUTH 355° P1'-2" 1' _ 21' 21'•1" 8°-11"��F1'-1" ROOF MATERIAL ASPHALT ASPHALT 51'-2" TOTAL NO OF PENETRATION 6 • ARRAY#2 RAFTER PROFILE 2•X 6• RAFTER SPACING 16.00 ROOF PITCH 27° ARRAY PITCH 27° ROOF AZIMUTH 175° ARRAY#4 ARRAYAZIMUTH 175° ZAY#3 ROOFF MATERIAL S IINNGGLE TOTAL NO OF PENETRATION 25 ARRAY#3 I I RAFTER PROFILE 2"X 6" ♦ i L I 1 I I I RAFTER SPACING 16.0C 1 1 I I I I I I I I I I I I I I I I I ROOF PITCH 27° 1 I I I I I I I I I I I I I I I ARRAY PITCH 27° 1 1 I I I I I I I I I I ROOF AZIMUTH 265° ARRAY AZIMUTH 265° 121-$" 121-p11 I I I ROOF MATERIAL S PHALE OO T 1 1 T ♦- 1 TOTAL NO OF PENETRATION 11 1 1 T I I ARRAY#4 1 RAFTER PROFILE 2"X 6' RAFTER SPACING 16.00 1 ROOF PITCH 27° , ARRAY PITCH zr 8' 01-611 9" ROOF AZIMUTH 65° I II O_� I R — a_ - ARRAY AZIMUTH 65° 19-1 8I-2 ASPHALT 19'-1" _ 0 ROOF MATERIAL SHINGLE •TAL NO OF PENETRATION 8 `'•,��H of�• JOB NUMBER: P-007446 OWNER: DESCRIPTION: AP: I, ` , os i G e n JANET K MASLOWSKI JANET K MASLOWSKI, y , P V—3.O UTILITY: NATIONAL GRID 22 BURNCOLT ROAD RESIDENCE / ,,,� .���. ergy Efficiency•Roofing DC SIZE:8.00 kW ��� PAGE NAME: 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS FLORENCE MA 01062 AC SIZE:7.60 kW V ^+�_f-'% ATTACHMENT PLAT 280 Moody St., ANNUAL PRODUCTION:8,007 kWH idlow,MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 ling Consulting,PLLC SCALE: LICENSES 7 N eadowkrook Drive,Alpine Ulm°. 1/8"=1'-0" LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER'S NAME:JANET MASLOWSKI assarhusettsCOANO01629764 DATE: C.#100105-EL-MR Signed 4/27/2023 INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANT REV: 3/30/2023 FRAME SECTION ROCKIT MOUNT ROCKIT MOUNT SILFAB SOLAR SIL-400 HC+ SILFAB SOLAR SIL-400 HC+ — ASPHALT —•'— � SILFAB SOLAR SIL-400 HC+ N . SHINGLE ASPHALT O \ ARRAY SKIRT Ilir - --1:4111.1.11-M SHINGLE \\`\ filiV ..—w::--:-:---,., 'FIN.OWED. EXISTING ASPHALT SHINGLE 12 LAG � 2'X 6`016"O.C. RAFTER o BOLT OR STRUCTURAL SCREW #12 LAG o N WITH 2-1/2"MIN.EMBEDMENT BOLT OR STRUCTURAL SCREW AND FLAT WASHER WITH 2-1/2"MIN.EMBEDMENT AND FLAT WASHER ROOF SECTION 1 SCALE:NONE 4TTACHMENT DETAIL Scale: NTS SILFAB SOLAR SIL-400 HC+ O // ® ARRAY SKIRT ROCKIT MOUNT i �/ SILM8 SOLAR SILiW HC+ EXISTING ASPHALT SHINGLE ASPHALT SHINGLE � 2'X 6'0 16"O.C.RAFTER ^_ r SKIRT O c‘l -,r ROOF SECTION 2 SCALE:NOW 2"X 6"RAFTER 0 16"O.C. M12 LAG BOLT OR STRUCTURAL SCREW WITH 2.1/2"MIN.EMBEDMENT AND FLAT WASHER LAR PV ARRAY SECTION VIEW 'l'Of ale: NTS 6 OWNER: DESCRIPTION: Lr�A�/v: 1 -'1 ` ' SOS I G e Cl JOB NUMBER: P-007446 JANET K MASLOWSKI, P V—4 0 JANET K MASLOWSKI ,o RESIDENCE UTILITY: NATIONAL GRID 22 BURNCOLT ROAD DC SIZE:8.00 kW /� s. F., PAGE NAME: ergy Efficiency•Roofing FLORENCE MA 01062 AC SIZE:7.60 kW ` /!NAL 4T' ATTACHMENT DETAI ..N SOSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS 280 Moody St., ANNUAL PRODUCTION:8,007 kWH idlow,MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 W• Zing Consulting,MC SCALE: LICENSES -7 .eadowt2EoOk Drive,AlPk1WUTB4004 NTS LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 - UTILITY CUSTOMER'S NAME:JANET MASLOWSKI .saathusetts00011001629764 DATE: C.#100105-EL-MR Signed 4/27/2023 INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANA REV: 3/30/2023 MODULE SPECIFICATION INVERTER CHARACTERISTICS-SOLAREOGE SE 7600H-US OPTIMIZER CHARACTERISTICS SOLEREDGE P505/S440 PHOTOVOLTAIC SYSTEM AMBIENT TEMPERATURE SPECS NUMBER OF CURREN I ER&MODEL NO. SILFAB SOLAR SIL-400 HC+ MAX OUTPUT POWER 7600 W RECORD LOW TEMP -IvPERCENT OF CARRYING CONDUCTORS IN DC INPUT POWER 505W „ow DC SYSTEM SIZE(kW) 8.000 AMBIENT TEMP(HIGH TEMP 2%) 33° VALUES EMT POINT CURRENT(IMP) 11.10 AMPS SYSTEM OPERATING VOLTAGE 400 V DC MAX INPUT VOLTAGE 80 V 60V AC SYSTEM SIZE(kW) 7.600 CONDUIT HEIGHT 1.0• .80 4-6 POINT VOLTAGE(VMP) 36.05 VOLTS MAX CONTINOUS OUTPUT CURRENT 32 A MAX OUTPUT CURRENT ISA ISA TOTAL NUMBER OF MODULES 20 ARRAY TOP TEMP M. .70 7-9 r VOLTAGE(00) 43.02 VOLTS MAX INPUT VOLTAGE 480 V IT CURRENT(ISC) 11.58 AMPS MINIMUM STRING LENGTH 6 8 NOMINAL AC VOLTAGE 240V CONDUCTOR TEMPERATURE RATE W' ,50 10-20 WER AT STC(PMAX) 400 WATT SYSTEM SHORT CIRCUIT CURRENT 15 A MAXIMUM STRING LENGTH 25 25 NOTE:-THE OPTIMIZER IS SELECTED AS PER SITE. BACKFEED FUSE SIZING ONNECTS MAX EFFICIENCY 95 % MAX.CONTINUOUS OUTPUT 32A©240V Go UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 32 X 1,25 = 40.00AMPS 40A FUSES-OK SOE 240V CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300,6(C)(1)AND ARTICLE 310.10(D). IIT LENGTH CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10(C). LENGTH APPRDx 2 H ALL BOS COMPONENTS WITHIN 10 FT OF UTILITY METER. METER NUMBER:23593296 TO APPRDxON i ALL BOS COMPONENTS WITHIN 10 FT OF UTILITY METER { Ei1Lv Tr TO POI APPROX 5 N (E)100A RATED I MET)uER MAIN SERVICE PANEL II 1A/ N 50H2 STRING-I, (E)100A/2P MAIN- _10 SILFAB SOLAR SIL400�r 2' 1 3" 1 rj' __ #BREAKER OP FED SOLAREDGE OPTIMIZER S440IP506 -POWER OPTIMIZERS 1 (N) (N)UNESIDE TAP VIA� LISTED CONNECTORS I- -- SOLAREOGE SE7800H•US INVERTER BilUNO.2 AC (N)100A SERVICE PANEL (NI 100A BREAKER- -10 BILFAB SOLAR SIL-400 MC. D (N)BO A FUSED :: AC DISCONNECT JUNCTION n - _-4-RAPID I OVERHEADTOUTILITY ILI r _ I SHUTDOWN 4ci -77 SWITCH L I o- I L _ U SOLAREDGE OPTIMIZER 8440/P505 POWER OPTIMIZERS 1 CONDUIT TO BE AL EMT AND CONDUIT DIA.IS MINIMUM WIRE FROM: CONDUIT WIRE WIRE WIRE'TYPE WIRE MATERIAL TEMP WIRE TEMP ADJUSTMENT WIRE STRING / MYOPERATING STRING X NEC = MAX MAX.SYSTEM GRND GRND Y GAUGE: _RATING: AMP DE-RATE: FACTOR: OCPD: WATTAGE VOLTAGE -AMPS AMPS VOLTAGE: SIZE WIRE TYPE ARRAY TO IN AIR 2 #10 PV WIRE COPPER 90° 40A x 0.96 x 1.00 = 38.4A 4000 / 400 = 10.00 X 1.25 = 12.50A 480 #6 BARE JUNCTION BOX JUNCTION BOX AL/EMT-3/4" 4 #10 THWN-2 COPPER 90° 40A x 0.96 x 0.80 = 30.72A 4000 / 400 = 10.00 X 1.25 = 12.50A 480 #10 THWN-2 TO INVERTER " INVERTER TO AC AL/EMT-3/4' 3 #8 THWN-2 COPPER 90° 55A x 0.96 x 1.00 = 52.8A = 32A X 1.25 = 40.00A 240 #10 THWN-2 DISCONNECT AC DISCONNECT AL/EMT-3/4" 3 #8 THWN-2 COPPER 90° 55A x 0.96 x 1.00 = 52.8A = 32A X 1.25 = 40.O0A 240 #10 THWN-2 TO SERVICE PANEL SERVICE PANEL AL/EMT-3/4' 3 #6 THWN-2 COPPER 90° 75A x 0.96 x 1.00 = 72.OA = 32A X 1.25 = 40.00A 240 #8 THWN-2 TO P01 DOS i G e n JOB NUMBER: P-007446 OWNER: DESCRIPTION: STAMP: JANET K MASLOWSKI JANET K MASLOWSKI, PV -5.O UTILITY: NATIONAL GRID 22 BURNCOLT ROAD RESIDENCEDC SIZE:8.00 kW PAGE NAME: ergy Efficiency•Roofing FLORENCE MA 01062 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS AC SIZE:7.60 kW THREE LINE DIAGRAI 280 Moody St., ANNUAL PRODUCTION:8,007 kWH ,slow, MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 : LICENSES NTS LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER'S NAME:JANET MASLOWSKI DATE: C.#100105-EL-MR INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANA REV: 3/30/2023 GROUNDING NOTES EQUIPMENT GROUNDING ALL EQUIPMENT SHALL BE CONDUCTORS SHALL BE SIZED NOTES : ROPERLY ALL EQUIPMENT GROUNDED PER THE ACCORDING TO NEC ARTICLE 1. MATING CONNECTORS SHALL COMPLY WITH NEC 690.33, REQUIREMENTS OF NEC 7 690.45,AND BE A MINIMUM OF 2. SOLAR EDGE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM(PVRSS),AS PER NEC ARTICLES 250 &690 #10AWG WHEN NOT EXPOSED 690.12(B). TO DAMAGE,AND #6AWG 3. THE SPECIFIED OPTIMIZER CAN BE SUBSTITUTED WITH A P400, P405, P505, P401, OR P485. THESE OPTIMIZERS INSTALLER SHALL CONFIRM SHALL BE USED WHEN HAVE AN INPUT VOLTAGE WINDOW WIDE ENOUGH TO ACCOMMODATE THE OUTPUT VOLTAGE RANGE OF THE "HAT MOUNTING SYSTEM HAS EXPOSED TO DAMAGE MODULE AT THE DESIGN TEMPERATURES, HAVE A MAX INPUT CURRENT RATING THAT IS ABOVE THE MAX OUTPUT BEEN EVALUATED FOR CURRENT OF THE MODULE,AND A MAX POWER INPUT THAT IS ABOVE THE RATED POWER OUTPUT OF THE MODULE, COMPLIANCE WITH UL 2703 4, DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE-OR GRAY-COLORED 'GROUNDING AND BONDING" 5, ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF NHEN USED WITH PROPOSED EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(A)AND PART III OF ARTICLE 250 AND PV MODULE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE PV MODULES SHALL BE SYSTEM SHALL ADHERE TO NEC 690,47(A)AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED GROUNDED TO MOUNTING ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. .AILS USING MODULE LUGS 6. MAX DC VOLTAGE OF ARRAY FIXED BY THE INVERTER AT 380V REGARDLESS OF TEMPERATURE. THE MAX DC OR RACKING INTEGRATED VOLTAGE OF THE MODULE AT-15°C IS 53.2V(-15°C-25°C)X-0.138V/C+47.7V= 53.2V). GROUNDING CLAMPS AS 7. POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT,INSIDE PANELBOARD ENCLOSURE ALLOWED BY LOCAL USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER JURISDICTION. ALL OTHER LOCALLY-APPROVED METHODS AND HARDWARE,IN COMPLIANCE WITH NEC 705.12(A). THE PANELBOARD SHALL <POSED METAL PARTS SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312.8(A) BE GROUNDED USING 8. PV SYSTEM DISCONNECT SHALL BE VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND UL-LISTED LAY-IN LUGS. LOCKABLE BY THE UTILITY, THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF ILSCO(ILSCO FOR GROUNDING AND BONDING TAP). DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72 2ONDUCTORS, IF INSULATED, SHALL BE COLOR CODED 3REEN, OR MARKED GREEN IF #4AWG OR LARGER AC SYSTEM GROUNDING LECTRODE CONDUCTOR(GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S .ESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. DOS I G e n JOB NUMBER: P-007446 OWNER: DESCRIPTION: STAMP: JANET K MASLOWSKI JANET K MASLOWSKI, PV -5.1 UTILITY: NATIONAL GRID 22 BURNCOLT ROAD RESIDENCE ergy Efficiency•Roofing DC SIZE:8.00 kW PAGE NAME: 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS FLORENCE MA 01062 AC SIZE:7.60 kW ELECTRICAL NOTEI 280 Moody St., ANNUAL PRODUCTION:8,007 kWH idlow,MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 NTS: LICENSES UTILITY CUSTOMER'S NAME:JANET MASLOWSKI LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 DATE: C.#100105-EL-MR INVERTER: (1) SOLAREDGE SE7600H-US REV: 3/30/2023 DESIGNED BY: KARAN RANA CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: MAIN DISTRIBUTION— UTILITY DISCONNECT =1 AC DISCONNECT -P: ] INVERTER&RAPID L- SHUTDOWN DC DISCONNECT SWITCH SERVICE PANEL PV ARRAY FRONT OF HOME 22 BURNCOLT ROAD FLORENCE MA 01062 DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN: NEC 690.56(B)&(C),[NEC 705.10)) DOS i G e n JOB NUMBER: P-007446 OWNER: DESCRIPTION: STAMP JANET K MASLOWSKI JANET K MASLOWSKI, PV -6.0 UTILITY: NATIONAL GRID 22 BURNCOLT ROAD RESIDENCEDC SIZE:8.00 kW PAGE NAME: ergy Efficiency•Roofing FLORENCE MA 01062 AC SIZE:7.60 kW PLACARD 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS ANNUAL PRODUCTION:8,007 kWH 280 Moody St., SCALE: idlow,MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 NTS LICENSES UTILITY CUSTOMER'S NAME:JANET MASLOWSKI LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 DATE: C.#100105-EL-MR INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANA REV: 3/30/2023 WARNING: PHOTOVOLTAIC LABEL6 FOR PV DISCONNECTING MEANS WHERE THE LINE AND AT DIRECT-CURRENT EXPOSED RACEWAYS.CABLE TRAYS.COVERS POWER SOURCE AND ENCLOSURES OF JUNCTION BOXES.MID OTHER WIRING METHODS, ELECTRIC SHOCK HAZARD POSMOO TERMINALS MAY BE ENERGIZED IN THE OPEN SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY TERMINALS ON THE LINE AND NEC 880.13(Bp ENCLOSURES WALLS.PART TONS.CEILINGS.OR FLOORS. NEC 680.31(GX384)) LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION wxiii FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED PLACED ADJACENT TO THE BACK-FED BREAKER TURN RAPID SHUTDOWN AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID FROM THE INVERTER IF TIE IN CONSISTS OF NIGH TO THE'OFF' SHUTDOWN SWITCHES IF NOT AT TFE SAME LOCATION. NIGH (NEC 590.38(CX1XA)I LOAD SIDE CONNECTION TO BUSBAR POSITION TO SHUT DOWN THIS EQUIPMENT IS FED BY MULTIPLE [NEC 705.12(BX2)(3)(bS PV SYSTEM AND REDUCE SOURCES.TOTAL RATING OF ALL SHOCK HAZARD IN ARRAY OVERCURRENT DEVICES,EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE,SHALL NOT EXCEED SOLAR PV SYSTEM EQUIPPED FAOSREPV SYSTEMS THAT ONLY SHUT DOWN AMPACITY OF BUSBAR. WITH RAPID SHUTDOWN CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON DR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO TURN RAPID SHUTDOWN ��+ WHICH THE PV SYSTEMS ARE CONNECTED AND ��AABBE�1 3 SWITCH TO THE'OFF' SHALL INDICATE THE LOCATION OF ALL IDENTIFIED PLACED ADJACENT TO THE BACK-FED SHEARER POSITION TO SHUT DOWN A _ _R' RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME FROM THE INVERTER IF TIE IN CONSISTS OF CONDUCTORS OUTSIDE LOCATION. INVERTER OUTPUT CONNECTION LOAD BIDE CONNECTION TOBUSBAR. THE ARRAY.CONDUCTORS MECgW.Se(CX1Xbp (NEC 705.12(BX2)(3XBp WITHIN THE ARRAY REMAIN III DO NOT RELOCATE ENERGIZED IN SUNLIGHT THIS OVERCURRENT DEVICE RAPID SHUTDOWN t � it LOCATED AT RAPID SHUT DOWN CyA1BB SWITCH F 0 R DISCONNECT SWITCH(NEC SS0.5B(CX3)). EOUEPMENT CONTAINING OVERCURRENT SOLAR PV SYSTEM DEVICES IN CIRCUITS SUPPLYING POWER DUAL POWER SUPPLY TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MAIN SERVICE PANEL SOURCES:UTILITY GRID AND PV MARKED TO INDICATE THE PRESENCE OF ALL St%nTRS(NEC 705.1205X311 SOLAR ELECTRIC SYSTEM O ® EXISTING BUS PANEL LIBELING DIAGRAM' PV COMBINER INVERTER IS) (IF WHERE POINT OF SUBPANEL- OMBINE PHOTOVOLTAIC AC DISCONNECT AT OF INTERCONNECTION.MARKED ° ° O O INTERCONNECTIONAD AC DISCONNECT IF OUTPUTSED TO CIRCUIT AT AC DISCONNECTING MEANS. PV OUTPUT CIRCUITS ® (NEC�'�•NEC BB0.131s)I RATED AC OUTPUT CURRENT. °°° O ® c00 = O = NOMINAL OPERATING AC VOLTAGE:®" 0 OR O ® O Oq i �I JUNCTION BOX jABELING NOTES' IN OR COMBINER SOX 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE O EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. (ONLY IF PV (ONLY IF PV O O _ 2. G REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD ONLYIINTERCONNECTION INTERCONNECTION 12010.145,ANSI Z535. CONSISTS OF LOAD CONSISTS OF LOADF.11 O O 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. SIDE BREAKER) SIDE BREAKER) 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC 110.21(BX3)] INTEGRATED DC DISCONNECT 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3NB',WHITE ON RED BACKGROUND;REFLECTIVE.AND 'ELECTRICAL DIAGRAM SHOWN ABOVE(8 FOR LABELING PURPOSES ONLY.NOT AN ACTUAL REPRESENATON OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED.LABEL PERMANENTLY AFFIXED(AFC 605.11.1.1] LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE Of INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. SOS I• G O I I JOB NUMBER: P-007446 OWNER: DESCRIPTION: STAMP `, JANET K MASLOWSKI JANET K MASLOWSKI, P V-7.0 RESIDENCE UTILITY: NATIONAL GRID 22 BURNCOLT ROAD DC SIZE:8.00 kW PAGE NAME: ergy Efficiency•Roofing FLORENCE MA 01062 'OSIGEN SOLAR RACKING: ECOFASTEN ROCKIT SMART SLIDE RAILLESS AC SIZE:7.60 kW SAFETY LABELS 280 Moody St., ANNUAL PRODUCTION:8,007 kWH )dlow, MA 01056 MODULES: (20) SILFAB SOLAR SIL-400 HC+ ACCOUNT NUMBER:40847-31004 : LICENSES NTS LECTRICAL LICENSE OPTIMIZER: (20) SOLAREDGE OPTIMIZER S440/P505 UTILITY CUSTOMER'S NAME:JANET MASLOWSKI DATE: C.#100105-EL-MR INVERTER: (1) SOLAREDGE SE7600H-US DESIGNED BY: KARAN RANA REV: 3/30/2023 Bill Of Materials JANET K MASLOWSKI 22 BURNCOLT ROAD FLORENCE MA 01062 Electrical Equipment CITY Part# Description 20 SILFAB SOLAR SIL-400 HC+ SILFAB SOLAR SIL-400 HC+Solar Modules 1 SOLAREDGE SE7600H-US(240V) SOLAREDGE SE7600H-US(240V) Inverter(s) 20 SOLAREDGE OPTIMIZER S440/P505 SOLAREDGE OPTIMIZER S440/P505 Optimizers 1 SE-GSM-R05-US-S1 SolarEdge GSM w/5 Year Plan 1 60A AC Disconnect AC Disconnect,60A, 240VAC, 2-Pole 5 Junction Box Junction Box 2 Tap Connectors Tap Connectors 1 100A Rated Service Panel 100A Rated Service Panel 1PH, 120/240V 60HZ Breakers and Fuses 1 100A 2-Pole Breaker(s) 100A 2-Pole Breaker(s) Racking 24 2011021 RI COUPLING AL LBK 68 2011024 RI COMP SLIDE AL BLK 68 2011020 RI MOUNT AL BLK 68 3012020 GF-1 FLASHING GLV BLK 8X10 8 N/A GROUNDING LUG ELECTRICAL SPECIFICATIONS 4OO Test Conditions STC NOCT - - - - + Module Power(Pmax) Wp 400 298 Maximum power voltage(Vpmax) V 36.05 33.50 Maximum power current(Ipmax) A 1110 8.90 Open circuit voltage(Voc) V 43.02 40.35 Short circuit current(Isc) A U.58 9.34 Module efficiency % 20.2% 18.8% systemvoltage(VDC) V - Maximum 1000 Series fuse rating A 20 Power Tolerance Wp 0 to+10 Measurement conditions:STC 1000 W/m'•AM 15•Temperature 25°C•NOCT 800 W/m'•AM 1.5•Measurement uncertainty<_3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by 0 to+10W. Module weight 213kgt0.2kg 471bs t0.41bs Dimensions(H x L x D) 1914mmx1036 min x35mm 75.3 in x 40.8 in x 1.37 in Maximum surface load(wind/snow)° 5400 Pa rear load/5400 Pa front load 112.8 Ib/ft rear load/112.8 Ib/f 2 front toed Hail impact resistance 0 25 mm at 83 km/h el in at 51.6 mph Cells 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 bulbar-326 x 6.531n Giant - - 32 mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) 1350 mm,0 5.7 mm,MC4 from Staubli I 53 in,0 0.22 in(12AWG),MC4 from Staub High durability,superior hydrolysis and UV resistanatmulti-layer dielectric film, Backsheet fluorine-free PV backsheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated Temperature Coefficient Isc +0.064 96/°C Module product anship warranty 25 years" Temperature Coefficient Voc -0.28 96/Y Linear power perfo ance guarantee 30 years Temperature Coef ldent Pmax -0.36%/°C >_97.1%end 1st yr 2 91.6%end 12th yr NOCT(±2°C) 45°C >_85.1%end 25th yr Operating temperature -40/4-85°C v 82.6%end 30th yr CERTIFICATIONS SHIPPING SPECS �■ UL 61215-1:2017 Ed.1°°°,UL 61215-2:2017 Ed.1'°°,UL 61730-1:2017 Ed.i UL 61730- Modules Per Pallet: 26 or 26(California) 2:2017 Ed.1°°°,CSA C.222061730-1:2019 Ed2°°°,CSA C2 2 216173 0-2 20 1 9 Ed2°° Product IEC 61215-1:2016 Ed.1***,IEC 61215-2:2016 Ed.1°°°,IEC 61730-1:2016 Ed.2°°°,IEC 61730-22016 Ed.2°°°,IEC 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Pallets Per Truck 32 r 31(Califomia) Corrosion),UL Fire Rating Type 2,CEC Listing*** - - Factory 15090012015 Modules Per Truck 832 or 806(California) • A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. °° 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"atsilfabsolar.com. PAN files generated from 3rd party performance data are available for download at:silfabsolar.com/downloads. °° Certification and CEC listing in progress.December 2022,expected completion. -_i l 75.3•[1914mm] 1 :r E 12.1•[307mm] 51.2[1300m ] 12.1•[307mm] ^m Mounting Hole(x4) Q SILFAB SO R INC. 800 Cornwall Ave Oligaries 0.5' Bellingham WA 98 25 USA [12mm] T+1360.569.4733 I info@silfabsolar.c m 3 o SILFABSOLAR.0 M u '" £ E 1770 Port Drive I1.4"[35mmL EE E £ Burlington WA98233USA f .C o,E o T+1360.569.4733 a) �� Ni W eo 240 Courtneypark Drive East E o el a Mississauga ON L5T 2Y3 Canada E= T+1905.255.2501 E O,Og• 53.15" cv ci F+1905.696.0267 --JI Cable Length II- o SiHab-SIL-400-HC+-2o221017 0) No reproduction of any kind is allowed without ci permission.Data and infomration is subject to Drainage Hole(x8) 0 0 modifications without notke.0 Sixab Solar Inc, ~- / + \ f - 2022.Silfab Solar•is a registered trademark of ... •••• • ..• SILFAB PRIME SILFAB • SOLAR® SIL-400 HC+ •� RELIABLE ENERGY. DIRECT FROM THE SOURCE . Designed to outperform. Dependable, durable, high-performance solar panels engineered for North American homeowners. SILFABSOLAR.CoM / Single Phase Inverter with HD-Wave Technology for North America Single Phase Inverter SE3000H-US/SE3800H-US/SES000H-US/SE6000H-US/ with HD-Wave Technology C SE7600H-US/SE10000H-US/SE11400H-US mMODEL NUMBER SE3000H-US SE3800H-US SES000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H u• for North America APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ OUTPUT Rated AC Power Output 3000 3800 i�240V • sox) 6000 833 24UV 7600 ___ i 1400 0 240V VA- SE7600H-US/SE10000H-US/SE11400H-US m 33oo•20RY 50000208V 1 •240V Maximum AC Power 38000240V 60000240V 11dW 0240V 12 2 573 Output 300° 33ao•208V 500° sago 0 208V 760D 100°D 10000.208V vA AC output Voltage Min:Nxoi-Mae. , . . . , vat YEAR (211-240-264) • WARRANTY AC Output Voltage Min.-Noe..-Max. - . - . 1 - I - . VA (183-208-229) I AC Frepercy(Nomnal) 59.3-80-60.5^ I Hz • 0 Maximum Continuous Output I 47.5 A Current 0240V 12.5 16 21 25 32 42 Maximum Continuous Output - 16 - 24 - I - 48.5 A Current 0208V O • Power Factor 1,Adjustable-0.85 to 0.85 • • GFDI Threshold 1 A • Utility Monitoring,Islandng Protection. gs Country Configurable Thresholds INPUT Maximum DC Pow.,02409 4650 5900 7750 9300 I 11800 15500 17650 W • wolwe,OJIQ —HD • R88 ....HD.... Maximum . Maximum DC Power 02089 - 5100 - 7750 I - - 15500 W t - �--.:-.— ----_-.-_---------7A. srnronmer-less.u _ 'its • • Maximum Input Voltage 480 6W 0 • Nominal in Input Voltage3eo 400 Maximum Input Current 0240W' 8.5 10.5 13.5 16.5 20 27 30.5 Ado Adc 1110 Maximum Input Current 0208V' - I 9 _ - 13.5 - -. _ -- 27 Mc Fil Max.Input Short Circuit Current 45 Adc O O O O Reverse-Polarity Protection Yes • _ • - Ground-fault Isolation Detection 600ha 5ensi0Nty 'Maximum inverter 8#6rr y 99 I Bel % CEC Werghted Efficiency 99 99.240✓ 96 98.5.208V Nghbime Power Consumption x 2.5 W Optimized installation with HD-Wave technology I5Fo,other,e alle„ings pleaserio,ta<,SolarEdge sopPy< - - - - - 12)A hater current puce may be we the emerm.will Ie t to v,P,t current to the vaunt steed / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance / Record-breaking 99%weighted efficiency / Small,lightweight,and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp / Built-in module-level monitoring / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in consumption metering(1%accuracy)and / Integrated arc fault protection and rapid shutdown production revenue grade metering(0.5%accuracy, for NEC 2014,NEC 2017 and NEC 2020 per article ANSI C12.20) 690.11 and 690.12 solaredge.com solar s e / Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/SE10000H-US/SE11400H-US '.tuli, SE3000H-US SE3800H-US 5E5000H-US SEN000H-US SE76O0H-US SES0000H-US SE114O0H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet ZgBee(option*,Cells., Revenue Grade Metering ANSI C12.20 -. - OPtiorufa -Consumption metering metering Inserter Commissioning With the SetApp mobile appeafldn using gelt-n Wi-fl Access Poet for Loot Connection Rapid Shutdown-NEC 2014.NEC Anaomatic Rapid Shutdown upon AC Grid Disconnect 2017 and NEC 2020.690.12 STANDARD COMPUANCE Safety UL174t 007415A.UL1699B,CSA C22Z Canadoe AFC according to tI.L M-07 Grid Connection Standards IEEE1547.Rule 21,R3#54 011) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output CoMult Size/AWG Range 1"Madrnum/14-6 AWG 1"Madman/14-4 AWG OC Input Conduit See/a of Sbkns/ 1^MOAnum/1-2 smngs/14-6 AWG 1"MYhom/1-3 stings/14-6 AWG AWG Range Dimensions with Safety Switch(6W+D) 17.7 314.6 x 6.8/450 0 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 In/man Weight with Safety Switch 22/10 I 25.1/11.4 I 262/11.9 3e8/17.6 b/kg Nose <25 <SO d8A Cooling Natural Convection Operating Temperature Range .40 to 4140/-4010.60's' /'C Protection Rating NEMA 4%(Inverter with Safely Switch) (3)wwerter WM Rrwwe Cade Mein P/N.SFaaN-U5000BNC4.wnerter a,M Rereme Wade Prosxam,and Comumpro Meter P/N S1enpH-US000BNl4 For conwarptldn nwpre4 mount rardomess should be ordered worn*SFAC10750-200NA.20 or SEACT0750.400r4A-20 20,avh per AN (4)fJ poser op b a 4aa 50'C/1227:br power de-ramp nb,maton Mir to'hops//wow sdreuge.conVsaeVdetauive sAe-temperature-deraunq-note-nap r How to Enable Consumption Monitoring 3y simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service Dane!,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter with HD-wave technology and built-in RGM and Service Panel consumption monitoring Grid o CT Lt N L2 Shielded CATSe cable 11. U V AC Conduit —en.D,,,7 0=0/.1”. MSuee.,,,.c..a.,.».nannotbKn Rolla / Power Optimizer 1:1 For Residential Installations Power Optimizer O S440, S500 S440 SS For Residential Installations Rated Input DC Power.. .V • AbsoluteM Input VoltageNOC) 60 Vdc MPPT Operating Range 6-60 Vdr SYYA AO $500M Maximum Short Crcua Current(Sc)a Co nnected w tlModue _ 15 AdC Maximum Efficiency 99.5 % T Weighted Efficiency — 966 % O.ervutageCategory II 25 OUTPUT DURING OPERATION Maximum Output Caren[ Adc Y f r1 K Maximum Output Voltage Voltage 60 I Vdc NA NA''�r'II� OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output voltage per Power Optimize 1--- 1 I Vac STANDARD COMPLIANCE EMC FCC Pet 15 Class 8.006100-6-2.0061000-6-3.CISP811,EN-55011 Safely 6C62109-1(dass II safely),1x1711 Material— ....._ 1K91 V-0,IN Resistant Yet ',.nf�y vDE-M-E 2xx1-7p2013-05 INSTALLATION SPECIFICATIONS Maximum Mooed System vwage 1000 Vdc N ater ono(Wal•E) 1t9e155s30 we Weight rmchdbg cedes) 655/1.5 ge/lb Input Connector MCI° ■ • ■ i Input Wile length 0.1 ell Output Connector MCI Output Wee length Lerg (.1 23.(-)0.10 en X Operating Temperature Range" -b to.85 Protection RatingIP60/NEMASP Relative Humidity 0-1W ..--_._. S" 1'l Rated pos.'',me mod*k Our at SIC me nee emceed the Power Optimum Rated bpi DC Power.Modules with upm.stc power tole ewe me Mowed -. . PV 5ystem Design Using a SolarEdge Single Phase hr.r Phase Three Phase fr,. HD-Wave 277/480VGrid Minimum String Length Maw r Operant-- 16 Enabling PV power optimization at the module level MaurnunString Length(Power Ogimvr 25 Madman Nominal Power per String., 5700 11250" I 12750. W Perak'Strings of Differed Lengths or CAkntatxxrs Yes / Specifically designed to work with SolarEdge / Mitigates all types of module mismatch loss,from "ppo'w"`er Reerto' power,we eonnumVsi "wdefeutt,,,powern„�'" - ergghye,°„°°"'g ,. ,,,°e„ ptr° P'°" "'""madmen npRa residential inverters manufacturingtolerance topartialshadin s)rate,e2lo/aoov god.eltowedtomtw pe r me.mm" pm.e,dfferenceonweeneachwonge2.800W g (6)for the 277/ee0V god s is allowed tomstall up to,.02 wm m per sung ' the a.nnum M paver dferenre xeen each smog is 2,000W (n a n red alb.d tp rm 5-series end F.wnes P"m+[lothwers m new hstabtans I Detects abnormal PV connector behavior, / Faster installations with simplified cable preventing potential safety issues* management and easy assembly using a single bolt / Module-level voltage shutdown for installer and / Flexible system design for maximum space utilization /' (a firefighter safety y�� 1" 1gCC / Superior efficiency(99.5%) / Compatible with bifacial PV modules `c@,a0 `r _. O .it E� -EV,— —.. - 4foweeeleyhelert m.wewer-modeled swm..«ewnsan solaredge.com solar • • = . p�. o b;4g00 m n a.�R ��R. CE RoHS w ..n .r anV"..m .dw", anowne. w. anNG . a tnob / Power Optimizer •eCi For North America Power Optimizer O P370/P400/P401 /P485/P505 Ntunizer model P370 P400 P401 P485 P505 For North America typical module compatibility) INPUT (for higher-power 60 (for 72&96- (for high power 60 (for high-voltage (for higher and 72-cell modules) cell modules) and 72 cell modules) modules) current modules) P370/P400/P401 /P485/P505 T Absolute Maumum lM ut Voltage so 8 • 60 ,2 5« T Noe at bwest temperature) r MPPT Operating Range 8-60 8-93 8-60 125-105 12.5-83 Vdc Maximum Short Circuit Current(Rc) 11 10.1 12.5 11 14 Adc 25 O MedMan DC Input Current ,3.75 125 11.65 12.5 17.5 •Mniraan Efficiency % % y 1,�1; _Weighted Efficiency 988 MO Ovnswtge Category N ,VAkkArl It OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Madmen Output Curren I 15 MC Maximum Output voltage 60 80 ' Vdc Z� OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) fil5 H STANDARD COMPLIANCE FCC Part 15 Class 8,RC61000-6-2.IEC61000 6-3 Safety ffC62 09-11doss II safety).UL1741.NECRVRSS N oH5 INSTALLATION SPECIFICATIONS M R UL91V-t,WRes ram 0 15 ow rT'1 _._Maximum Allowed System Voltage 1000 Vdc Compatible inverters MSdarEdge SRgle Phase erg Thee Phase kneMas Dimensions N/xLx H) 129 x153 x2r.5/ 129 x153x 33.5/ 129 x153x29.5/ 129x159t49.5/ 129x162.59/ min 5.,x6x,.1 S.tx6x 13 5.1x6x1.M S.tx63x7.9 5.1x64x23 /n Weigh(including cables) 750/1.7 655/1.5 845/,.9 ,064/13 g/b Input Connector MC4w kICIv k/C1or Input WAe Length 0.1E/0.5 m/R Output Wire Type/Connector Double Insulated/MC4 Output Non Length 1.2/39 m/R opeamg Temperature Range• -40 to.85/-40 to.185 'C/T Protection Rating e68/Type68 Relative Humidity 0-100 % (II Rated pew dew moGne et SIC we not eared Me cgmare'Rated Input 0C Pare'.seAMi with wl0.5%poem bream.Owed (2)HEC 2017 morn row input voltage b m not than 80V SarEctio PV power optimization at the module-level micro.,cornrow rtFh14N1r44bR“4.kr micro., aew.5S64.tie.Fnoo dnonweea15Mtree PaloresO ISlev ampentkrnpnme rbwe.QSY/.dKS parr a+aRry n appYetl.Refer no Pores OPetdeen Tearwaue R-IGg Technical mine b rove Merp Mtpa'/Mww.mlwwwlpe confutes... e—reron:recle•anng naeroptl! / Specifically designed to work with SolarEdge / Fast installation with a single bolt PV System Design Using a Solar+dqe Single Phase Three Phase for Three Phase for inverters Single phase Inverter' HD-Wave 208V grid 277/480V grid / Next generation maintenance with module- / Up to 25%more energy level monitoring iii,,iop ..,sr jP4e5.P505 • 6 l 8 14 • Maximumxstag Length(Power Optimizers) n n 50 / Superior efficiency(99.5%) / Meets NEC requirements for arc fault Maximum Power Per song W-U57036(6000 Mat 6000w I2750` w 5E76 S-sE1H00•115) 5250-6--1 protection(AFC')and Photovoltaic Rapid Parallel Strings of Different Lengths orOrientations Yes / Mitigates all types of module mismatch losses, Shutdown System(PVRSS) (6110reeehed Wog mug...on rarer bnw,/wwwwmdx 00m/seet....A.fflimistnno_sreopunepre from manufacturing tolerance to partial (hit rs.eitem.1tom.P.85.505.01p37tWoWNat n one song t814 Ong*oh more awn 30apemnndas rot meet NEC,apd dxapawn reaeenrxx army weage mite Mae t a 30Vrepvwnm shading / Module-level voltage shutdown for installer weoraevg.4deb .'m insue 00 en 6.SOOW per strIN when tise reesifrunn power diffelente Nenteleramw2IsLOOw and firefighter safety (Wm7lrpew gr.e'n Ownd Minced up to 15.000W put string when the mwmwn power di0venn beaten each mig A 2,01w2 / Flexible system design for maximum space utilization solaredge.com solar • • = µo � b). g �R en..,�..,e h n�rads.v„oftiv.awa.raa� u.Fsars.,a�w�Ss.N Sses.chew....aw.,.,aa. ar p RoHS w�a ..,,a .,, M, ,mawan.id.tp� w 4wne.n . or Mtertek /LSCO. KUP-L-Tap® connections Insulation Piercing Connectors RoHS ® a) matter Compliant LISTED tq + Dual Rated 453G TYPEFeatures Benefits •'�� Body is molded from tough,resilient glass-filled nylon •Provides high degree of breakage resistance and long dependable use •Compact design •Saves space •Tin plated copper contact teeth •Easily penetrates most types of insulation gpl.Eaf •Insulation piercing •No need to strip the conductor which saves installation time �c s'" •Perforated end tabs •Break out easily by hand •Pre-filled with silicone lubricant •Prevents oxidation and moisture from entering the contact area V•-t •Versatile •Can be used as a splice or tap connector =_ •Increased safety •Contains no external energized parts.Can be installed"hot"on energized conductors providing tap conductor is not under load. •Horizontal line grid •Provides a visual guide for proper installation of conductors •Temperature rating 90°C W L lil C III ..., OIH Fig.1 Fig.2 Fig.3 Fig.4 Catalog Figure Wire Range Current Rating Dimensions Torque Bolt Head Number Number Main Tap Volts CU AL L W H Ft.Lbs. Size IPC-1/0-2 3 1/0-8 2-8 3001480 Grounded Y System) 130 100 1-7/32 1-15/32 2-5/16 16 1/2 IPC-4/0-6 2 4/0-4 6-14 600 75 60 1-27/64 1 1-7/8 13 1/2 IPC-4/0-2/0 3 4/0-2 2/0-6 600 195 150 1-21/32 1-7/8 2-7/8 25 1/2 IPC-250-4/0 2 250kcmil-1 4/0-6 600 260 205 1-7/8 2-11/32 3-11/32 30 5/8 IPC-350-4/0 3 350kcmil-4/0 4/0-10 300(480 Grounded Y System) 260 205 1-43/64 2-7/16 3-1/8 25 5/8 IPC-350-350 4 350kcmil-4/0 350kcmil-4/0 300(480 Grounded V System) 350 280 2-43/64 2-23/32 3-1/4 25 5/8 IPC-500-12 1 500kcmil-250kcmil 10-12 300(480 Grounded Y System) 40 35 1-43/64 2-7/16 3-1/4 25 5/8 IPC-500-250 1 500kcmil-250kcmil 250kcmil-4 600 290 230 2-27/64 2-29/32 3-3/4 55 5/8-11/16 IPC-500-500 1 500kcmil-300kcmil 500kcmil-250kcmil 600 430 350 3-3/16 3-5/8 5 15 7/8-7/8 IPC-750-500 1 750kcmil-500kcmil 500kcmil-350kcmil 600 430 350 3-3/16 3-5/8 5 75 7/8-7/8 All wire sizes,unless noted otherwise,are American Wire Gauge(AWG) Tested to UL 486A/B,UL File E6207 ROCKIT SMART SLIDE EcaFasten Integrated UltraGrip Technology'. Pre-installed sealing pads are compatible with all composition shingle roofs.The compression achieved when fastened to the „ roof creates a super strong watertight seal.In most cases,the ROCKIT, slide can be mounted to the deck without the need for sealant. A layer of flexible foam provides cushioning,which allows the waterproofing sealant to embed deep into the granules of the shingle as well as to flexibly conform over the steps found on INTRODUCING ROCKIT SMART SLIDE! architectural-style shingles. Introducing EcoFasten's patent pending Rocklt Smart Slide,our simple solution for quickly installing the popular Rocklt rail-less racking system to composition shingle roofs. ... Features&Benefits 'o • Eliminates the need to pry up shingle �� • courses and install a metal flashing • Multiple opportunities to find the rafter �: —,_ _ • No need for additional material when architectural shingles are not level A layer of flexible foam pushes the sealant deep Into Rocklt Smart Slide can be installed on top thr.hinplr gr.,n„irs and shingle steps of architectural shingles steps • Longer 6.75"slide avoids overlaps in shingle courses • Integrated flashing utilizes UltraGrip Technology'.to create Testing&Documentation a watertight seal ROCKIT SMART SLIDE • UL441 Rain Report • Florida ProductAporoval • TAS 100(A1-95 Wind and Wind Driven • Rocklt Installation Manual Required Components: Rain Resistance • RQckIrstitshept4 Part Number: Description: • Mechanical Load Test/Structural 2011024 RI SMART SLIDE BLK 6.75" Saparity edification 2011025 RI SMART SCRW#12X3"W/BW *EcoFostene 4141 W. VAN BUREN ST, SUITE 2, PHOENIX AZ 85009 Ec0EAStEn150CA13.Com \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ F. t,, a.m„y 'I-877-859-3947--t THE-OVECOFASTENSOLAR.COM S PZ structura ENGINEERS January 13,2023 EcoFasten Solar LLC 4141 W Van Buren St,Ste 2 Phoenix,AZ 85009 TEL: (877)859-3947 Attn.: Eco Fasten Solar LLC-Engineering Department Re: Report#2015-05884HG.06.01—EcoFasten- Rocklt System for Gable and Hip Roofs Subject: Engineering Certification for the State of Massachusetts PZSE, Inc.—Structural Engineers has provided engineering and span tables for the EcoFasten- Rocklt System,as presented in PZSE Report#2015-05884HG.06.01, "Engineering Certification for the EcoFasten-Rocklt System for Gable and Hip Roofs". All information,data, and analysis therein are based on,and comply with,the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-10&7-16 Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2012,2015,&2018 International Building Code 3. 2012, 2015,&2018 International Residential Code 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 5. Aluminum Design Manual 2010&2018, by The Aluminum Association, Inc. 6. ANSI/AWC NDS-2015&2018, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II Seismic Design Category=A- E Exposure Category= B, C& D Basic Wind Speed (ultimate)per ASCE 7-16=90 mph to 180 mph Ground Snow Load =0 to 60(psf) This letter certifies that the loading criteria and design basis for the DIGITALLY SIGNED EcoFasten-Rocklt System Span Tables are in compliance with the above codes. A*" �-cN OFM , o •AUL K. G I ' •CHER m{ If you have any questions on the above,do not hesitate to call. o •UCTURAL n jij Prepared by: • FS SIONAL PZSE, Inc.—Structural Engineers Roseville,CA 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E WELCOME TO THE r-t, PosiGen Family ! RESIDENTIAL SOLAR SYSTEM LEASE AGREEMENT SO $ 119.99 20 YEARS UP-FRONT COST MONTHLY PAYMENT INITIAL TERM 426 tiit)• • O__ WE WILL DESIGN, IF YOU NEED TO MAKE WE WILL PERFORM THE SOLAR PANELS INSTALL,OPERATE, PROPERTY REPAIRS. ENERGY EFFICIENCY COME WITH A 25-YEAR MAINTAIN AND WE WILL REMOVE AND SERVICES INTENDED PERFORMANCE INSURE A SOLAR REINSTALL THE TO INCREASE YOUR WARRANTY.AND WE ENERGY SYSTEM ON SYSTEM TO ALLOW ENERGY COST PROVIDE A LIMITED YOUR HOME. FOR THE REPAIRS. SAVINGS. WORKMANSHIP ADDITIONAL FEES APPLY. WARRANTY. DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E ;rim Pos i G e Customer Name(s): Janet K Maslowski Account No.: 221585 RESIDENTIAL SOLAR SYSTEM LEASE AGREEMENT (Home Improvement Contract) Transaction Date: March 3, 2023 Account No.: 221585 Date of Customer Signature: December 27, 2022 Approximate June 28, 2023 Approximate Installation July 28, 2023 Installation Start Date: Completion Date: Janet K Maslowski Phone: (413) 335-3690 Customer Name(s): - jkmaslowski@comcast.net E-Mail: 22 Burncolt Rd, Customer Mailing Northampton, Property Address: 22 BURNCOLT RD, Address: FLORENCE, MA 01062 Massachusetts 01062 Our Promises: Your Commitment: • We will design, install, operate, maintain and • Pay the Monthly Payment each month. insure a solar energy system on the roof of your • Provide access to your property and roof. home. • Continue service with your Utility. • We will perform energy efficiency services at no • Comply with your obligations in this additional charge to you. agreement. • We warranty that our work will be free from • Respond promptly to us when we need defects and roof penetrations will be watertight information or cooperation from you. for five (5) years. • Keep us informed of any property transfers • Throughout the initial term, we will service and involving your home. maintain the solar energy system and will remove • Cooperate with us to perform an energy it for a fee if you need to repair your home. efficiency assessment and install upgrades. • The solar panels come with a minimum 25-year • Keep your roof in good condition throughout performance warranty from the manufacturer. the initial term of this agreement. If you move, you may: At the end of 20 years, you may: • Transfer this agreement to the home buyer; • Renew the agreement; • Prepay the agreement; • Purchase the system; • Pay a fee, and we will remove the system; or • Enter into a new agreement with us; or • After the 6th anniversary, purchase the system. • Ask us to remove the system at no cost. You may cancel this agreement any time before we begin work at or near your Property associated with installation of the system or Energy Efficiency services. PosiGen Developer, LLC (EIN: 87-4400455) is a licensed contractor in each state in which we operate, including MA. Our contractor license numbers are included as part of Exhibit D to this agreement. For information about our licenses, please visit http://www.posigen.com/licenses. The Notice of Cancellation may be sent to: PosiGen Developer, LLC, 819 Central Avenue, Suite 210, New Orleans, LA 70121, Attention: Document Compliance. DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E ;FL POS I G e n Customer Name(s): Janet K Maslowski Account No.: 221585 EXH I BIT A LEASE DISCLOSURES We are required by law to deliver to you the following disclosures: Account No.: 221585 Customer Name(s): Janet K Maslowski Property Address: 22 BURNCOLT RD, FLORENCE, MA 01062 System Size (kW): 8.30 First Year Estimated 8,508.21 Performance (kWh): Equipment Leased: We will install solar panels, together with inverter(s), racking, cabling and other components. Solar panels may be manufactured by one or more of the following: Canadian Solar, Hanwha Solar, JA Solar, Jinko Solar, LG Solar, Silfab Solar, and/or Trina Solar.* *This description of leased equipment is an estimate. We do not anticipate that the equipment listed above will materially change prior to installation. However, we reserve the right to change the Proposed System Design, System Location, and components of the System in accordance with the terms of the Agreement. Payment Dates: As set forth in Section 3(b) of the Lease, the Monthly Payment is due upon your receipt of the invoice. All payments are due on the due date reflected on the invoice. Payment Frequency: Monthly Number of Payments: 240 during Initial Term of the Lease. Total Cost of Lease: $28,797.60 Monthly Payments: $119.99 Insurance: You are not required to have insurance specifically for the System. You are required to have insurance for the Property on which the System is installed. Early Purchase Option: If you elect the Early Purchase Option set forth in Section 4(j) of the Lease, the price will be determined by reference to a readily available independent source that we will identify and disclose to you at least ninety (90) days prior to the beginning of the Early Purchase Period. Amount Due at Other Charges Estimated Total of (not part of your Payments Lease Signing or Monthly Payments: Monthly (the amount you will have Delivery: Payment): paid by the end of the Lease): Your Monthly Payment each month Nothing. * Nothing. $28,797.60 throughout the Initial Term is $119.99. Your first Monthly Payment is due one month after the Activation [ ate, which is estimated to be the twentieth (20th) of the month, and your further payments are due within ten (10) days of the invoice date thereafter. The total of your monthly payments is $119.99* *These amounts include taxes. DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E 7 r POS I G l.rn. Customer Name(s): Janet K Maslowski Account No.: 221585 If you elect the End of Initial Term Purchase Option set forth in Section 2(a)(ii) of the End of Initial Term Lease, the price will be determined by reference to a readily available independent Purchase Option: source which we will identify and disclose to you at least one hundred eighty (180) days prior to the end of the Initial Term. Other Important See the Lease for additional information on early termination and maintenance Terms: responsibilities, warranties, default charges, activation fees, insurance, and any security interest, if applicable. r.. nc Ot- Customers BY INITIALING, YOU ACKNOWLEDGE RECEIPT OF THESE LEASE DISCLOSURES, Initials: AS OF THE TRANSACTION DATE. DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E J L 7 r POS I G e n Customer Name(s): Janet K Maslowski Account No.: 221585 • 44, • � t r � Module Panel, Canadian Solar 415w HiKu Mono CS3N- MS/BW/415 Wattage 415 #of Modules 20 Inverter DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E ::`Er PO S I G e n Customer Name(s): Janet K Maslowski Account No.: 221585 EXHIBIT B SYSTEM DESIGN (see attached) • • • Fs r TO DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E 7 r POS I G l.r 1 I Customer Name(s): Janet K Maslowski Account No.: 221585 EXHIBIT C NOTICE OF CANCELLATION (Customer Copy) Transaction Date: March 3, 2023 Account No.: 221585 YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE (3) BUSINESS DAYS FROM THE ABOVE DATE, OR (IF LATER) UNTIL THE START OF ANY WORK AT OR NEAR YOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM OR THE EE SERVICES. IF YOU CANCEL,ANY PROPERTY TRADED IN,ANY PAYMENTS MADE BY YOU UNDER THE CONTRACT OR SALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE;OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER, OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE, OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO POSIGEN DEVELOPER, LLC AT 819 CENTRAL AVENUE, SUITE 210, NEW ORLEANS, LA 70121, ATTENTION: DOCUMENT COMPLIANCE NOT LATER THAN MIDNIGHT OF OR (IF LATER) UNTIL THE START OF ANY WORK AT OR NEAR YOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM OR THE EE SERVICES. I HEREBY CANCEL THIS TRANSACTION. Date: Customer's Signature: Customer(s) J114 BY INITIALING, YOU ACKNOWLEDGE RECEIPT OF THIS NOTICE OF Initials: CANCELLATION, AS OF THE TRANSACTION DATE. DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E 7 r POS I G e rt Customer Name(s): Janet K Maslowski Account No.: 221585 NOTICE OF CANCELLATION (PosiGen Copy) Transaction Date: March 3, 2023 Account No.: 221585 YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE (3) BUSINESS DAYS FROM THE ABOVE DATE, OR (IF LATER) UNTIL THE START OF ANY WORK AT OR NEAR YOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM OR THE EE SERVICES. IF YOU CANCEL, ANY PROPERTY TRADED IN,ANY PAYMENTS MADE BY YOU UNDER THE CONTRACT OR SALE,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER, OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO,THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE, OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO POSIGEN DEVELOPER, LLC AT 819 CENTRAL AVENUE, SUITE 210, NEW ORLEANS, LA 70121, ATTENTION: DOCUMENT COMPLIANCE NOT LATER THAN MIDNIGHT OF OR (IF LATER) UNTIL THE START OF ANY WORK AT OR NEAR YOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM OR THE EE SERVICES. I HEREBY CANCEL THIS TRANSACTION. Date: Customer's Signature: DocuSign Envelope ID:BBBE7559-6DB2-4393-BE14-989FE6853F6E PosiGen 7 r Customer Name(s): Janet K Maslowski Account No.: 221585 EXHIBIT D STATE DISCLOSURES (Massachusetts) 1. Our Licenses. For information about contractor license and registration requirements, contact the Massachusetts Office of Consumer Affairs and Business Regulation at 888.283.3757 or online at https://www.mass.gov/orgs/office-of-consumer-affairs-and-business-regulation. PosiGen Developer, LLC (EIN:87-4400455)is a licensed contractor in Massachusetts, License No. 205094. For general information about our licenses, please visit http://www.posigen.com/licenses. 2. Implied Warranties. Notwithstanding any language in the Agreement stating or implying otherwise,there are no limits under Massachusetts law on the implied warranties of merchantability or fitness for a particular purpose in connection with this Agreement. Po Customer(s) ts) BY INITIALING, YOU ACKNOWLEDGE RECEIPT OF THESE STATE DISCLOSURES, Initials: AS OF THE TRANSACTION DATE.