30A-053 BP-2023-0501 56 LIBERTY ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 30A-053-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0501 PERMISSION IS HEREBY GRANTED TO: Project# 2023 SOLAR Contractor: License: PIONEER VALLEY Est. Cost: 25920 PHOTOVOLTAICS CS106329 Const.Class: Exp.Date: 03/14/2024 Use Group: Owner: BAILEY BOURNE ALDEN &KATE Lot Size (sq.ft.) Zoning: URB Applicant: PIONEER VALLEY PHOTOVOLTAICS Applicant Address Phone: Insurance: 311 WELLS ST - SUITE B (413)772-8788 375928710105 GREENFIELD, MA 01301 ISSUED ON: 04/24/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 15 PANEL ROOF MOUNTED SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I 9- 1 *r 'e, • i . f Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissi ner r..t Jr_ ! V — I f Th Commonwealth of Massachusetts :•and f Building Regulations and Stand rds FOR (,4APR 2 1 �� sa huselts State Building Code,780 CVIR MUNICIPALITY USE I Building Permit App1 cation To Construct,Repair,Renovate Or Demolish a Revised Mar 2011 suit DING INSPECTIONVne-or Two-Family Dwelling nN "i* r.M1o1C`:n This Section For Official Use Only Buildinley g.Permit Naoss umber:j3 P-20I 2.3 —OS-0 l Date Applied: i�.7 �74�_ Zy-Zb23 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 56 Liberty St,Northampton,MA 01062 `3 0 lf� oc3 —o b , 1.la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: C..1R13 , c14BacrG Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Alden Bourne Northampton,MA 01062 Name(Print) City,State,ZIP 56 Liberty St. (917)816-2437 acbourne©gmail.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.0 Number of Units Other El Specify:Solar PV Brief Description of Proposed Work-: Installation of a 15 panel roof mounted PV array.System size 6kW DC/6kW AC. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $9,072 1. Building Permit Fee: S Indicate how fee is determined: 2.Electrical $16,848 ❑Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5.Mechanical (Fire Suppression) Total All Fees: $ Check No.j3672Check Amoun 7 Cash Amount: 6.Total Project Cost: S 25,920 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-106329 03/14/2024 MAYA FULFORD License Number L.,.. Expiration Date Name of CSL Holder List CSL Type(see below) u 159 CLARK DRIVE No.and Street Type Description GUILFORD VT 05301 U Unrestricted(Buildings up to 35,000 Cu.ft.) R Restricted 1&2Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-772-8788 BUILDINGPERMITS@PVSQUARED.COOP 1 Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 140077 9/15/2023 PIONEER VALLEY PHOTOVOLTAICS COOP HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 311 WELLS STREET.SUITE B BUILDINGPERMITS@PVSQUARED.COOP No.and Street Email address GREENFIELD MA 01301 413-772-8788 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes El No . 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Pioneer Valley Photovoltaics Coopertive to act on my behalf,in all matters relative to work authorized by this building permit application. SEE ATTACHMENT (A) SEE ATTACHMENT(A) Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. 4/4/2023 �' - Print Owner's or Auth iced Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at txww.mass.cov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts 1, Department of Industrial Accidents ='= _ 1 Congress Street,Suite 100,) G Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Annlicant Information Please Print Legibly Name (Business/Organization Individual): Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address:311 Wells Street, SuiteB City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): LEI I am a employer with 38 employees(tall andior part-time).* 7. New construction 2.0 I am a sole proprietor or partnership and have no employees working for me in 8. E3 Remodeling any capacity.[No workers'comp.insurance required.] 3.0I am a homeowner doing all work myself.[No workers'comp.insurance required.]t 9. El Demolition 4.0I am a homeowner and will be hiring contractors to conduct all work on my property. I will 10 0 Building addition ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13. ROOFrepairs These sub-contractors have employees and have worker'comp.insurance.: 6.0 are a corporation and its officers have exercised their right of exemption per MGL c. 14. Other Solar PV 152.§1(4).and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. r Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractor that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees.they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance fin•my employees. Be/on'is the policy and job site information. Insurance Company Name:Ohio Casualty&Security/Liberty,and Continental Indemnity/AUW Policy#or Self-ins.Lic.#:37-592871-01-05 'Expiration Date:01/01/2024 Job Site Address:56 Liberty St. City/State/Zip:Northampton, MA 01062 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal vi)lation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cer,if;•,t.rer the and penalties ofperjnrl•that the information provided above is true and correct. Signatu Date:4/4/2023 Phone#:413-7 8738 Official use no ly. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: PROJECT INFORMATION: S Q U 4 R Project Bourne ��^� L. Northampton 44 �`* Client: Alden Bourne ,(`XxjJ\) ///III 1. Address: 56 Liberty St 4,q 1* Northampton,MA 01062 N T s 50` =� ;'I1 PV SQUARED SOLAR SYSTEM DETAILS 311 WELLS STREET,SUITE B Total System Size: 6.8 kW-DC SOLAR �/ GREENFIELD,MA 01301 6kW-AC SOLAR FIRE ACCESS PATHWAYS '�-� MIN. 6"WIDE wwwwSOUARED.COOP 413-772A7B8 modules- (17)Hanwha Q Cell 400 BLK Q PEAK DUO G10+ Optimizers: (17)SolarEdge S440 Alt.Optimizers: PRO3CC [at.opa P401,P505,S440,ssoo) BOURNE Inverters: (1)SolarEdge 6kw HD-Wave w/RGM NORTHAMPTON DESIGN CRITERIA CDENT: ALDEN BOURNE Ground Scow Load: 40(psi Design Wind Speed: 117(mph) SITE Exposure Category SR LIBERTY ST Risk Category: IF: NORTNAMP70N,MA 01062 AUTHORITY HAVING JURISDICTION 9 Building: Kevin Ross(413)587-123 Electrical: Roger Malo(413)587-1244 ......................................................_..................__..........._..............._....._..._.............._......_ __ Electrical Utility: NGrid i Code Ret. 2023 NEC(MA) . ZNN PROJECT NOTES I u — SOLAR ARRAY (HOUSE ROOF) UTILITY SERVICE METER SOLAR PV DISCONNECT (OUTSIDE) MAIN LOAD CENER MAIN SERVICE DISCONNECT SOLAR PV EQUIPMENT (BASEMENT) SITE PLAN& PROJECT INFO. 'rt.e�u. _ REV: 0 DATE: 3r2720x3 BY: ROBIN CREAMER SCALE: NO SCALE SIZE: 11x17 N irk PLAN 0AERIAL MAP OSITE PV—M 1 A NOT TO SCALE NOT TO SCALE DATE(MM/DD/YYYY) ACORO`f CERTIFICATE OF LIABILITY INSURANCE 01/05/2023 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Kathy Parker NAME: Alera Group, Inc. A/CONNo E>tt): (413)586-0111 FAX C,No): (413)586-6481 Webber&Grinnell Division E-MAIL kparker@webberandgrinnell.com ADDRESS: 8 North King Street INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURER A: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltaics Cooperative,Inc. INSURER C: Continental Indemnity/AUW 28258 Attn:Kim Pinkham INSURER D: 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: CL231519687 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLSUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE /� OCCUR DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 15,000 A BKS57072282 01/01/2023 01/01/2024 PERSONAL&ADVINJURY $ 1'000,000 GEN'LAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 PRO POLICY 2,000,000 JECT LOC PRODUCTS-COMP/OPAGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ B OVvNED X SCHEDULED BAS57072282 01/01/2023 01/01/2024 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED NON- WNED PROPERTY DAMAGE $ AUTOS ONLY X AUTOS ONLY (Per accident) Underinsured motorist $ 300,000 X UMBRELLA LIAB OCCUR EACH OCCURRENCE $ 5,000,000 A EXCESS LIAB CLAIMS-MADE US057072282 01/01/2023 01/01/2024 AGGREGATE $ 5,000,000 - DED X RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- ANDEMPLOYERS'LIABILITY STATUTE ER Y/N O1, OFF000,000 PROPRIETOR/PARTNER/EXECUTIVE EL,N N/A 375928710105 01/01/2023 01/01/2024 EACHACCIDENT $ OFFICER/MEMBMEMBER EXCLUDED? (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1 000 000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ , Blanket BPP $1,483,977 Commercial Property A BKS57072282 01/01/2023 01/01/2024 Transportation $25,000 Installation $75,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) Worker's compensation includes MA and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Proof of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID:65485C32-5B6E-4EB6-A4A2-DF79AEDB5295 Attachment A: AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above, and I agree to pay the contract price according to the Terms of Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. I hereby authorize Pioneer Valley PhotoVoltaics Cooperative to proceed with the above-referenced Project in accordance with this Agreement. I further authorize Pioneer Valley PhotoVoltaics Cooperative, or its designated representative, to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley PhotoVoltaics Cooperative for marketing purposes. A check for the First Payment is enclosed and I am returning this Agreement within 14 days of the Proposal date. Alden Bourne 2/22/2023 I 7:58 AM EST Printed Name Date Do/cuSigned¢by: aLLUA, bettnu. System Owner \ 2 43tb76by(.. 4-1i) Signature Title Proposal and Agreement#00017698 Page 7 of 13 Alden Bourne-February 17,2023 yati4 ,f Roof 24' ,i Roof 33'-2" '� t. P X Array 2904• X X Array 207 X - R/: g s°y t t • PVSQUARED SOLAR 1�, ..L.... .. I SUITE(1T)204w ll"._I.....('17')8�i) r Xj'../�4i�53• y"..� GREENFIELD,MA 01301 m i 1 \ 41&772A7B8 ED.000P WWW.PVSOUAR o _ my I.. __. • __.CC PROJECT: m ® -,0 ;— m --a 0 i 0— - e-- 64 I ® 1 "•—c - BOURNE a .._ _,._ • { t + NORTHAMPTON lq is E : . ce Q _.__. CLIENT: • co ALDENBOURNE . a SITE: N r...gr.... 0.... 56 LIBERTY ST ( ` \ NORTHAMPTON,MA 01062 RAFTERS 24"OC 1� SUNMODO NANOMOUNT BASES RAIL INSTALL ON DECKING 48"OC TYP. 4 SCREWS PER BASE NOTES: OARRAY LAYOUT INSTALL ATTACHMENTS ON RAFTERS AS NEEDED SCALE:yle•=1• ANIMAL GUARD AROUND ARRAY PERMIETERS ROOF SPECIFICATIONS ATTACHMENT SPECIFICATIONS Material. Composite Shingles Bases/Flashing: SUNMODO NANOMOUNT Attachment Structure. Decking/Truss Alternate Base/Flashing. IronRidge Halo Ultra Grip -- pitch: 30° Fasteners: DF#14-10 z 2'MP(Decking Screws) 3. Azimuth: 150° Alternate Fastemers: DF#12-16 x 3"MP(Rafter Screws) Sealant: CHEMLINK M-1 114" MODULE SPECIFICATIONS MODULE MODEL: Haowha 0 Cell 400 BLK O PEAK DUO G10+/Q.Peak DUO Max.Spacing: 54"USE 48"TYP. i ....... ...... 3 BLK ML-G10+400 1 Dimensions: 73.98•x 41.14•x 32mm Clamp Long Side: 3/4"-19 5/8 ARRAY LAYOUT 3. Clamp Short Side:-- ------ -- -, ...--- -- -- -- ..-- ------I 4 3/4"-11 3/4" ARRAY NOTES Framing and attachment locations to be verified on site. &ROOF DATA 198• RAIL SPECIFICATIONS Bases are staggered to distribute point loading except at edges of array. 74" REV: O Make 8 Model: XR10/XR100 Aamonnal or alternative bases may be used m t anusroofcondition.rrcondition. DATE: 327/2020 Clamp Torque: 80 in-lbs Ironndge Rail Gap Spacing ale Horizontal Spacing.rla vertical Spacing) BY: ROBIN CREAMER AS SHOWN L-Foot Torque: 250 irHtn 3/8-Horizontal Spacing 14 418" --it Max Cantilever. 24 va va al SpacingSCALE SIZE: 11x17 OMODscuE:ULEv4•=r DETAIL PV-M 2 A Snu4�4 140N a �j�\� O ,RT SOr PV SQUARED SOLAR 311 WELLS STREET.SUITE B GREENFIELD,MA 01301 W W W.PVSOUARED.000P 013-772.8788 PROJECT: BOURNE NORTHAMPTON I ' CLIENT: ALDEN BOURNE SITE: 56 LIBERTY ST NORTHAMPTON,MA 01062 MODULE MAP REV: 0 DATE: 327/2023 BY: ROBIN CREAMER SCALE: NO SCALE SIZE: 11317 PV-M4 NiE ,,, r ,,,7 rcr% Rel_,1...„ E n G P f1 E E ri 5 VSE Project Number:U1898.0154.231 March 17,2023 PV Squared 311 Wells St. Ste.B Greenfield,MA 01301 REFERENCE: Bourne Residence:56 Liberty Street,Northampton,MA 01062 PV Squared Project: BONO22022023R Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code:Massachusetts State Residential Code(780 CMR Chapter 51,9th Edition(2015 IRC)) Risk Category: II Design wind speed,Vult: 117 mph(3-sec gust) Wind exposure category:C Ground snow load,Pg:40 psf Flat roof snow load,Pf: 35 psf Existing Roof Structure Roof structure:2x8 rafters @ 24"o.c. Roof slope:22°&45° Conclusions Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. The glass surface of the solar panels allows for a lower slope factor per ASE 7, resulting in reduced design snow load on the panels. The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 807.4 of the 2015 IEBC as referenced in 780 CMR Chapter 34,9th Edition are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 10" above the roof surfce) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the ad Lion of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Increases in lateral forces less than 10% are considered acceptable. Thus the existing lateral force resisting system is permitted to remain unaltered. 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-177 /F(801)990-1776/www.vectorse.com VSE Project Number: U1898.0154.231 VECT Bourne Residence a R 3/17/2023 E 1'l Q 1 f"-1 � E F2 S Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering, LLC should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables.The design of the solar panels, solar racking(mounts,rails, etc.) and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. Vector Structural Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING,LLC oti,OF Ado. Ica WELLS L. G HOLMES t 8 STRUCTURAL va No.54240 03/17/2023 Wells Holmes, S.E. MA License: 54240-Expires: 06/30/2024 Project Engineer Enclosures WLH/rsl 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vectorse.com OB NO.: U1898.0154.231 C111 II= UBJECT: GRAVITY LOADS E n G I l E E R PROJECT: Bourne Residence GRAVITY LOADS Roof Pitch: 4.8 :12 Design material Increase due to Material weight ROOF DEAD LOAD (D) weight [psf] pitch [psf] Composite Shingles 2.2 1.08 2.0 1/2" Plywood 1.1 1.08 1.0 Framing 3.0 3.0 Insulation 0.5 0.5 1/2" Gypsum Clg. 2.2 1.08 2.0 M, E & Misc 1.5 1.5 Total Existing Roof DL 10.4 PV Array DL 3.2 1.08 3 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-10 Table 4-1 Roof Live Load With PV Array [psf] 20 SNOW LOAD (S): Existing w/ Solar Array Roof Slope [x:12]: 4.8 4.8 Roof Slope [°]: 22 22 Ground Snow Load, pg [psf]: 40 40 ASCE 7-10, Section 7.2 Terrain Category: C C ASCE 7-10, Table 7-2 Exposure of Roof: Fully Exposed Fully Exposed ASCE 7-10, Table 7-2 Exposure Factor, Ce: 0.9 0.9 ASCE 7-10, Table 7-2 Thermal Factor, Cf: 1.1 1.1 ASCE 7-10, Table 7-3 Risk Category: II II ASCE 7-10, Table 1.5-1 Importance Factor, Is: 1 .0 1.0 ASCE 7-10, Table 1.5-2 Flat Roof Snow Load, pf [psf]: 35 35 ASCE 7-10, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]: 0 0 ASCE 7-10, Section 7.3.4 Unobstructed Slippery Surface? No Yes ASCE 7-10, Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-10, Section 7.4 Roof Slope Factor, Cs: 1.00 0.80 ASCE 7-10, Figure 7-2 Sloped Roof Snow Load, ps [psf]: 35 28 ASCE 7-10, Equation 7.4-1 Design Snow Load, S [psf]: 35 28 JOB NO.: U1898.0154.231 EC ■ O R SUBJECT: LOAD COMPARISON E n 3 I n E E R s PROJECT: Bourne Residence Summary of Loads Existing With PV Array D [psf] 10 14 Lr[psf] 20 20 S [psf] 35 28 Maximum Gravity Loads: Existing With PV Array (D + Lr)/Cd [psf] 24 27 ASCE 7-10, Section 2.4.1 (D+S)/Cd [psf] 39 36 ASCE 7-10, Section 2.4.1 (Cd=Load Duration Factor=0.9 for D,1.15 for 5,and 1.25 for Lr) Maximum Gravity Load [psf]: 39 36 I Ratio Proposed Loading to Current Loading: 92% OK The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 807.4 of the 2015 IEBC as referenced in 780 CMR Chapter 34, 9th Edition are met and the structure is permitted to remain unaltered. JOB NO.: U1898.0154.231 VECT 111111111SUBJECT: SOLAR LAYOUT PROJECT: Bourne Residence b Y gYmwfi' S * 3p,--- .£� +�e ' ) " fir a ., 8 k � � b .ki may„ w lip . e..,'' ¥' ,1 i. • L. ' 4 "`e 'er::?.,., , powered by Q.ANTUM /Duo/ I 1 4, kit ,. J i t • II \ 3{1( j9S {} Q. PEAK DUO BLK ML-G10+ 385-405 ENDURING HIGH YR PERFORMANCE EUPD RESEARCH 0000.Q 'I TOP BRAND PV mapuLES i 400.4) 2021, Warranty GI CELLS °. Y;eid Security BREAKING THE 20°%EFFICIENCY BARRIER t111JJf Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Zr----- Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry:The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY r9::: Optimal yields,whatever the weather with excellent low light and temperature behavior. %'c_ ENDURING HIGH PERFORMANCE rt^J, Long-term yield security with Anti LID Technology,Anti PID v Technology,Hot-Spot Protect and Traceable Quality Tra.QTm. (Z' EXTREMEtech WEATHER RATING High aluminum alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). A RELIABLE INVESTMENT pwYeue>s Inclusive 25-year product warranty and 25-year 11� linear performance warranty2. 'APT test conditions according to IEC/TS 628044:2015.method A(-1.500V,96h) 'See data sheet on rear for further information. THE IDEAL SOLUTION FOR: e Rooftop arrays or. r sidentiai btukling, Engineered in Germany Q CELLS MECHANICAL SPECIFICATION Format 74.0in x 41.1 in x 1.26 in(including frame) (1879mm x 1045mm x 32mm) - 740'(1579tall,) ••-- I oar(1058 mm) 156-(395.6 mm) Weiq tt 48.51bs(22.0kg) 7 1 - (1250 mm) Front Cover 0.13in(3.2 mm)thermally pre-stressed glass with I+ :49.r1 . k I anti-reflection technology 4.Grounding point..o.18(4.5mm) Fnm.--, Back Cover Composite film 39.r(996mm) Frame Black anodized aluminum 0 411'(1045 mm) Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98in x 1.26-2.36in x 0.59-0.71in (53-101mm x 32-60mm x 15-18mm),IP67,with bypass diodes 14'"-0 249.2(1260mm) Cable 4mm2 Solar cable;(+)t49.2in(1250mm),(-)a49.2 in(1250mm) e.o,.i.9enme. 4 4 Connector Staubli MC4;IP68 I + -I Mounting>�e(onuLA( I [ �1.26•(35 mm) ocrAIL A°.63' rn,mm) OM'(24.5 mm)I_I°'33•(B.5mm) 1 ELECTRICAL CHARACTERISTICS POWER CLASS 385 90 395 400 405 CRMANCE AT STANDARD TEST CONDITIONS,STC' O _Z 3: LERA =CE .5W;._ W) Power at MPP' PMpp [W] 385 890 395 400 405 Short Circuit Current' Isc [A] 11.04 11.07 11.10 11.14 11.17 E E Open Circuit Voltage' Voc [V] 45.19 45.23 45.27 45.30 45.34 E Current at MPP IMPp [A] 10.59 10.65 10.71 10.77 10.83 Voi Lege at MPP VMpp [V] 36.36 36.62 36.88 37.13 37.39 Efficiency' n [%] 19.6 s19.9 a20.1 a20.4 a20.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Power at rv1PP PMPP [W] 288.8 252.6 296.3 300.1 303.8 E Short Circuit Current Isc [A] 8.90 E.92 8.95 8.97 9.00 E Open Circuit Voltage Voc [V] 42.62 42.65 42.69 42.72 42.76 Current at MPP IMpp [A] 8.35 8.41 8.46 8.51 8.57 Voltage et MPP VM9P [V] 34.59 34.81 35.03 35.25 35.46 'Measurement tolerances PMpp t3%;Isc;Vac t5%at STC:1000 W/m2,25t2°C,AM 1.5 according to IEC 60904-3.2 00 W/m2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE roo a rod ..w„ .; At least 98%of nominal power during 1' up 1 T T -r n first year.Thereafter max.0.5% ix ' ' FL degradation per year.At least 93.5% tr,100_ L _ of nominal power up to 10 years.At y �- least 86%of nominal power up to ..... 25 years. , b L L L L. Z [ All data within measurement toleranc- i a es.Full warranties in accordance with t0 200 400 600 800 1000 0 the warranty terms of the Q CELLS u+nno{Avct s/m,, sales organisation of your respective o 20 country. 1r 4° P ° Typical module performance under low irradiance conditions in v comparison to STC conditions(25°C,1000 W/m2) m .._.._ cil TEMPERATURE COEFFICIENTS o Temperature Coefficient of{, a [%/K] +0.04 Temperature Coefficient of V;:;" 0 [%/K] -0.27 c? Temperature Coefficient of P,,,;,,: y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109±5.4(43±3°C) m 0 D PROPERTIES FOR SYSTEM DESIGN 0 w Maximum Sysern Voltage V„, [V] 1000(IEC)/1000(UL) PV module classification Class II o Maximum Series ruse Rating [A DC] 20 Fire Rating based-on ANSI/Ut.5.1.730 TYPE 2 Max.Design Load.Push/Pull' [Ibs/ft2] 75(3600Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F oo o Max.Test Load,Push/Pull' [Ibs/ft2] 113(5400 Pa)/84(4000 Pa) an Continuous Duty (-40°C up to+85°C) d rn 3See Installation Manual i ,Ti QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION 0 UL 61730,CE-compliant, [ a Quality Controlled PV-TUV Rheinland, G. �® IG 0�-0-1 I ,�C� o IEC 61215:2016,IEC 61730:2016, p U.S.Patent No.9,893,215(solar cells), S 1' ( E ,aMB«a.nd Horizontal 76.4 in 43.3in 48.0 in 16561bs 24 24 32 m QCPV Certification ongoing. C US ♦♦♦ packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules a91730 49 UL 81730 I0 1111220277 p to Note:Installation instructions must be followed.See the installation and operating manual or contact our technical servi:e department for further information on approved installation and use of this product. Henwhe 0 CELLS America Inc. 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA I TEL+1 949 748 59 96 I EMAIL inquiry@us.q-cells.c m I WEB www.q-cells.us IRONRIDGE XR10 Rail See Descri tion / Length [/ - — .62 1p.46 t Rail Section Properties Property Value 1.67 i Total Cross-Sectional Area 0.363 in 1.75 1.33 Section Modulus (X-axis) 0.136 in __IMoment of Inertia (X-axis) 0.124 in4 58 Moment of Inertia (Y-axis) 0.032 in4 / Torsional Constant 0.076 in3 J -� Polar Moment of Inertia 0.033 in4 1.00 i Clear Part Black Part Description / Length Material Weight Number Number XR-10-132A XR-10-132B XR10, Rail 132" (11 Feet) 4.671bs. XR-10-168A XR-10-168B XR10, Rail 168" (14 Feet) 6000-Series 5.95 lbs. Aluminum XR-10-204A XR-10-204B XR10, Rail 204" (17 Feet) 7.22 lbs. vi.o IRONRIDGE Bonded Splice, XR10 Rail shown for reference O r 1 ITEM NO DESCRIPTION QTY IN KIT 1 SPLICE, XR10, MILL 1 Part Number Description XR10-BOSS-01-M1 Bonded Splice, XR10 1 ) Bonded Splice, XR10 BONDING SPRING STOP TAB ALIGNMENT CIRCLE 0.88 -- - ,.. \f -� 11.00 0.61 1.29 1 Propery Value Material 6000 Series Aluminum Finish Mill v1.o IRONRIDGE XR100 Rail ,i See Description / Length f. Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in` .66 Section Modulus (X-axis) 0.297 ini .46 Moment of Inertia (X-axis) 0.390 in4 Moment of Inertia (Y-axis) 0.085 in4 Torsional Constant 0.214 Polar Moment of Inertia 0.126 in4 1.99 APPROVED MATERIALS: 2.44 6005-16, 6005A-T61, 6105-15, 6N01-16 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) .58 ,,........_. i 2 _-........_ Clear Part Black Part Description/Length Material Weight Number Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) 6000-Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 1 1.60 lbs. v1.1 IRONRIDGE XR100 Bonded Splice - ' 0 XR-100 RAIL c• ad���� s.,. 12.0 Po' ,,, ::,,„:„.....„ A O XR-100—SPLC—BD Ilk KIT, XR100 BONDED SPLICE to ir 0 1) Splice, XR100, Mill 12" long 2) Screw, Self Drilling t 1.24 1 .63 1.93mu .31 (hQ II e at �I II1111��► 0.42 .15 H— #12-14— . TYPE "B"THREAD Property Value Property Value Material _ 6000 Series Aluminum Material 300 Series Stainless Steel Finish Mill finish Clear vi.0 >;:rw' ‘ 'pia _ -. �4CZTO - > _ @R:,.. e l E:.aer�r:_. %.>T* SUNMWDD Cut Sheet NanoMount f ae lw c; SAs 10T.6j + � r —_-- 9T 0 o a Material:Aluminum low Finish:Black Powder Coating —a— HEik-S—:‘,0- esoa nx 0o.tr�'` f s 106.e1 lab of NanoMount Gasket +--P24 PO) -.Ose Di Part Number Description + K50058-BK1 NanoMount . NanoMouni . USWR Gasket Material: USWR Gasket with Adhesive D10214-V003 Dimensions shown ore inches(ond millimeters) Details ore subiecl to change without nceice SUNMIDE1 Cut Sheet Lag Bolt Assembly NanoMount Lag Bolt 1. Hex Lag Bolt M8X115, DIN 571, 304 , 9,,._. . I �9 , `w/ EX ct',i y, IN ,io l G i Material:Stainless Steel Finish:Clear 2 Sealing Washer.33ID X.75X.157 t i i i , ` 1 au.ro 1 Cti® € 00n ( i.. € MA I NanoMount Decking Screw ' __ `\ Material: EPDM+Stainless Steel Decking Screw Assembly dt 1. Self-Tapping Screw,#6.3 X 76 0 300 0041 ' -' ''' d sinat taul , Material:Stain Finish:Clear Part Number DescriptionI 2. Sealing Washer .26ID X .50X .125 K50049-BK1 Lag Bolt Assembly • Hex Lag Bolt M8X115, DIN 571, 304S ,'r \ ..,,� • Sealing Washer.33 ID X.75 X .157 - r \ I ! /j F — 1 K50055-BK1 Decking Screw Assembly " • Self-Tapping Screw,#6.3 X 76 f • Sealing Washer.26lD X.50X.125 Material: EPDM+ Stainless Steel D10214-V003 Dimensions sh n are inches(and millimeters) Details ore subject to change without notice DEBRIS DISPOSAL AFFIDAVIT In accordance with the provisions of M.G.L. c. 40, s. 54, Building Permit # was issued with the condition that all debris resulting from this work shall be disposed of in a properly licensed solid waste disposal facility as defined by M.G.L c. 111, s. 150A. The debris will be disposed of in: WTE Recycling Name of Waste Facility 75 Southern Ave, Greenfield MA 01301 Address of Waste Facility 111.5 Debris: As a condition of issuing a permit for the {lemolition, renovation, rehabilitation or other alteration of a building or structure, M.©.L. c.40 s. 54 requires that the debris resulting therefrom shall be disposed of in a properly licensed solid waste disposal facility as defined by M.G.L.c. 111 s. 150 A.Signature of the permit applicant, date and number of the building permit to be issued shall be indicated on a form provided by the Building Department and attached to the office copy of the building permit retained by the Building Department. If the debris will not be disposed of as indicated, the holder of the permit shall notify the building official,in writing,as to the location where the debris will be disposed. 780 CMR—6th Edition Rebecca Spradley (PV Squared) Signature of Permit Applicant 4/24/2023 Date