36-118 (8) BP-2023-0455 232 BROOKSIDE CIR COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 36-118-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0455 PERMISSION IS HEREBY GRANTED TO: Project# 2023 SOLAR Contractor: License: SUNRUN INSTALLATION SERVICES Est. Cost: 20529 INC CS-090170 Const.Class: Exp.Date: 05/09/2024 Use Group: Owner: PERRY,ANDREW J. & PERRY, EMELDA T. Lot Size (sq.ft.) Zoning: URA/WSP Applicant: SUNRUN INSTALLATION SERVICES INC Applicant Address Phone: Insurance: 150 PADGETTE ST UNIT A (978)793-8584 WC614287601 CHICOPEE, MA 01022 ISSUED ON: 04/14/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 28 PANEL 7.6 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: . 'r . . T II Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Commonwealth of Massachi-tsetts APR 1 3 20 Board of Building Regulations and tandards Ft \i,j' Massachusetts State Building Code,780,C�1 ---- _ '4:7-LE C ETV-7E75--1 UNILITY '., .d CF t3U1LDING) SPECTI Building Permit Application To Construct,Repair, Renovate Ytmrlt WtoEoiser 2011 One-or Two-Family Dwelling _ -- ' This Section For Official Use Only Building Permit Number: ,/ L ).3• S Date Applied: /'��-vI _ /' s, ,/4Z (- Iu-2a2:3 Building Official(Print Name) Signature Date ECTION 1:SITE INFORMATION 2szpitss()t€Ncie 2 1.2 Assessors Map&Parcel Numbers 1.la Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: _ Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' i2.)1t Oreezd:ckx.vut , , • e ri Ck i tate,ZIP 1 C 1, o.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2 (check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repalrs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg.❑ Number of Units Other El'Specify: Solar Installa Work2:Installation of roof top photovoltaid solar system#of module 5e 1325f2tiribposed SECTION 4:ESTIMATED CONSTRUCTION COSTS - Item Estimated Costs: Official Use Only ( abor and Materials) 1.Building Li/0 1:4 2 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $1(/„u -/',,c,❑Standard City/Town Application Fee W it/i6 0 Total Project Cost (Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: t� /�Check N.o� Check Amount: . Cash Amount:': 6.Total Project Cost: $ 52q• Vim+0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction S ipervisor License(CSL) CS-090170 05/09/2024 Robert J Decker IV, IV License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 150 Padgette St Unit A No.and Street Type Description • U Unrestricted(Buildings up to 35,000 cu.ft.) Chicopee,MA 01022 R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry ' RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-259-8044 pioneervalleypermits@sunrun.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 180120 10/13/2024 Sunrun Installation Services Inc • HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 225 Bush St Suite 1400 pioneervalleypermits@sunrun.com No.and Street Email address San Francisco,CA 94104 41 .259-8044 City/Town,State,ZIP Telephone 1 SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes e No .0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Sunrun Installation Services Inc to act on my behalf,in all matters relative to work authorized by this building permit application. SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information ntain d'n this a licati n' true and accurate to the best of my knowledge and unders d. g. rin Owner's or Authorized Age ame((Electronic Signature) to NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massac zusetts * Department of Industrial Acc4dents :'l0— Office of Investigations Lafayette City Center eei ' '�z 2 Avenue de Lafayette, Boston, MA 02111-1750 WWW.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Sunrun Installation Services _ Address: 225 Bush St STE 1400 City/State/Zip: San Francisco CA 94104 Phone #: 415-946-7500 Are you an employer? Check the appropriate box: Type of project(required): 1.® I am a employer with 50 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. El Building addit"on [No workers' comp. insurance comp. insurance.: required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof re irs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' IA Other comp. insurance required) Ny> t *My applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. I Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy land job site inforination. Insurance Company Name: American Zurich Insurance Company Policy#or Self-ins. Lic. #:WC614287601 Expiration Date: 1 0/01/2023 Job Site Address: 2?5Z <5cAO t .'E*jQ C1 .1 City/State/Zi j\t Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby c fy under the pains and penalties of perjury that the information provided above is true and correct Si ature: C) - LL Date: 2/8/2023 Phone#: Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): 11:1Board of Health 20 Building Department 30City/Town Clerk 4.0 Electrical Inspector 5EIPlumbing Inspector 6.0Other Contact Person: Phone#: ��..IN SUNRINC-02 LWANG2 ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 44.........--- 8/31/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement( ). _ PRODUCER License#0C36861 CONTACT Walter tanner NAME: Alliant Insurance Services,Inc. PHONE FAX ' 560 Mission St 6th Fl (A/C,No,Ext): (A/C,No): San Francisco,CA 94105 E-MAIL Walter.Tanner@alliant.com INSURER(S)AFFORDING COVERAGE _ NAIC# INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:Zurich American Insurance Company - 16535 _ Sunrun Installation Services,Inc INSURER c:American Zurich Insurance Company_- 40142 775 Fiero Lane,Suite 200 Ph#805-540-7643 INSURER D: San Luis Obispo,CA 93401 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MIPOLICY EFF POLICY EXP LIMITS LTR INSD WVD IMDD/YYYYI (MMIDD/YYYYI, A X COMMERCIAL GENERAL LIABIUTY EACH OCCURRENCE $ 2,000,000 CLAIMS-MADE X OCCUR MKLV5ENV103749 10/1/2022 10/1/2023 DAMAGETORENTED 1,000,000 PREMISES fEa occurrence) $ MED EXP(Any one person) $ 5,000 PERSONAL 8,ADV INJURY $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY X JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER:Retention:$100,000 1Per Project Agg $ 5,000,000 B AUTOMOBILE LIABILITY (Ea ac identSINGLE LIMIT $ 2,000,000 X ANY AUTO BAP614287701 10/1/202; 10/1/2023 BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY _ AUTOS BODILY INJURY(Per accident) $ AUTOS ONLY AUTO y��ONLYEp (Per ac ident)DAMAGE $ X Raped.: X Coll.:Not Coverred Liability Ded.: $ 250,000 UMBRELLA UAB _ OCCUR EACH OCCURRENCE $ _ EXCESS UAB CLAIMS-MADE AGGREGATE $ _ DED RETENTION$ _ _ $ C WORKERS COMPENSATION X PER ATUTE EOTH AND EMPLOYERS'UABIUTY YIN WC614287601 10/1/202! 10/1/2023 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below - E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Workers'Compensation Policy WC614287601 Deductible:$1,000,000. Evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE City of Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Y P ACCORDANCE WITH THE POLICY PROVISIONS. 212 Main St Northampton,MA 01060 ----- -- AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD City of Northampton ? r,.L._ S. C -�!' Massachusetts �? i_ e ve t41 ' • �;; a' DEPARTMENT OF BUILDING INSPECTIONS y; ` 212 Main Street • Municipal Building Jj.. CFe \\ "`"` i-' Northampton, MA 01060 tSf ,,�0 CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: Location of Facility: 686 MAIN ST HOLYOKE MA The debris will be transported by: Name of Hauler: Casella Waste Signature of Applicant: 41cc` 7i4A.uCi Date: 4/12/2023 THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs and Business Regulation 1000 Washington Street- Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration M » 1 r !r ter,__.. _- t Type: Supplement Card = 'egistration: 180120 SUNRUN INSTALLATION SERVICES INC. -n =FMB 7 Expiration: 10/13/2024 21 WORLDS FAIR DR r • NIIINNalt SOMERSET, NJ 08873 `� �a ; d1 MN Ilair Notra. S ! Update Address and Return Card. THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs&Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE:Supplement Card Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street -Suite 710 180120 1 10/13/2024 Boston,MA 02118 SUNRUN INSTALLATION SERVICES INC. , /ROBERT J.DECKER IV 225 BUSH STREET *• ,- e(.� ,r,. / rr -- { �. �/ )� SUITE 1400 at,a (• �� L c� +� SAN FRANCISCO,CA 94104 Undersecretary Not Valid without signature Commonwealth of Massachusetts Division of Occupational Licensure Board of Building R ulations and Standards Const(ttonrS visor •CS-090170 FCpires:0510912024 ROBERT J DDCKER fl/,IV 77 FEDERAL,T MONTAGUE 1 A 0134$ • ‘t(:)f.LA4:13 4 =. EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com 4/12/2023 RE:Structural Certification for Installation of Residential Solar ANDREW PERRY:232 BROOKSIDE CIR, NORTHAMPTON, MA,01062 Attn:To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report,the roof is made of Composite shingle roofing over roof plywood supported by 2X4 Trusses at 16 inches.The slope of the roof was approximated to be 18 degrees. After review and based on our structural capacity calculation,the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 117 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf Ground Snow S 40 psf If you have any questions on the above, please do not hesitate to call. STRUCT ONL Sincerely, y\FA��k°FMAss40 � y VINCENT G(*, Vincent Mwumvaneza, P.E. 0 MWUMVANEZA N EV Engineering, LLC N'C) 2 projects@evengineersnet.com /,� Eso ��e http://www.evengineersnet.com �• ONALEN' Signed 4/12/2023 1/1 . EV projects@evengineersnet.com 276-220-0064 uma ENGINEERS http://www.evengineersnet.com Structural Letter for PV Installation 4/12/2023 Job Address: 232 BROOKSIDE CIR NORTHAMPTON, MA,01062 Job Name: ANDREW PERRY Job Number: 041223AP Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet 1 Cover 2 Attachment checks 3 Snow and Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2015 IRC(ASCE 7-10)-CMR 780 9th Ed Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 40 psf Wind Load (component and Cladding) V -mph Exposure B References NDS for Wood Construction STRUCT .. , ONL �-k 10.1 Aggss9 cy Sincerely, 4' VINCENT '� O MWUMVANEZA CIVIL w N�. Vincent Mwumvaneza, P.E. 1( EV Engineering, LLC ;/%;%J%: ER��NO, projects@evengineersnet.com ' ONAIENG Signed 4/12/2023 http://www.evengineersnet.com 1/1 AO . EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Wind Load Cont. Risk Category= II ASCE 7-10 Table 1.5-1 Wind Speed (3s gust),V= mph ASCE 7-10 Figure 26.5-1A Roughness= B ASCE 7-10 Sec 26.7.2 Exposure= B ASCE 7-10 Sec 26.7.3 Topographic Factor, Kn= 1.00 ASCE 7-10 Sec 26.8.2 Pitch= Degrees Adjustment Factor,A= 1 ASCE 7-10 Figure 30.5-1 a = 2.10 ft ASCE 7-10 Figure 30.5-1 Where a:10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than 4%of least horizontal dimension or 3ft(0.9m) Uplift(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= -20.5 -28.8 -45.5 Figure 30.5-1 Pnet=0.6 x A x KZT x Pnet30)= 12.29 17.31 27.29 Equation 30.5-1 Downpressure(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pnet30= 11.0 11.0 11.0 Figure 30.5-1 Pnet=0.6 x X x KZT x Pnet30)= 6.58 6.58 6.58 Equation 30.5-1 Rafter Attachments:0.6D+0.6W(CD=1.6) Connection Check Attachement max.spacing= : :ft 266 Ibs/in Manufacturer Test Lag Screw Penetration 2.5 in Prying Coefficient 1.4 Allowable Capacity= 512 Ibs 0.6D+0.6W Dpv+0.6W Zone Trib Width Area(ft) Uplift(Ibs) Down(Ibs) 1 5.3 17.2 180.6 165.1 2 5.3 8.6 133.6 82.5 3 2 3.4 87.0 32.7 Max= 180.6 < 512 CONNECTION IS OK j 1. Pv seismic dead weight is negligible to result in significant seismic uplift,therefore the wind uplift governs 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. 1/1 111. WOK. EV projects@evengineersnet.com 276-220-0064 mom ENGINEERS http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing _ Pg= 40 psf ASCE 7-10, Section 7.2 pf= 28 psf Ce= 0.9 ASCE 7-10,Table 7-2 Pfmin. = 35.0 psf Ct= 1.1 ASCE 7-10,Table 7-3 ps= 35 psf 40.4 plf Is= 1.0 ASCE 7-10,Table 1.5-1 CS 0.867 Max Length, L= 6.67 ft Tributary Width,WT= 16 in Dr= 10 psf 13.33 plf PvDL= 3 psf 4 plf Load Case: DL+0.6W Pnet+PP cos(0)+Poi= 26.1 plf Max Moment, M„= 81 lb-ft Conservatively Pv max Shear 82.5 lbs Max Shear,V„=wL/2+Pv Point Load = 140 lbs Load Case: DL+0.75(0.6W+S)) 0.75(Pnet+Ps)+ PPVcos(0)+PDT= 54 plf MdoWn= 167 lb-ft Mallowable=Sx x Fb' (wind)= 534 lb-ft > 167 lb-ft OK Load Case: DL+S Ps+ PP cos(0)+PoL= 58 plf Mdown= 178 lb-ft Mallowable=Sx x Fb' (wind)= 384 lb-ft > 178 lb-ft OK Max Shear,V„=wL/2+Pv Point Load = 192 lbs Member Capacity t $ ';( : Design Value CL CF C; C, Adjusted Value Fb= 875 psi 1.0 1.3 1.0 1.15 1308 psi F„= 135 psi N/A N/A 1.0 N/A 135 psi E = 1400000 psi N/A N/A 1.0 N/A 1400000 psi Depth, d = 3.5 in Width, b= 1.5 in Cross-Sectonal Area,A= 5.25 in2 Moment of Inertia, Ixx= 5.35938 in4 Section Modulus,Sxx= 3.0625 in3 Allowable Moment, Masi= Fb'Sxx= 333.8 lb-ft DCR=M /Mali= 0.44 < 1 .i , Allowable Shear,Vaii=2/3F„'A= 472.5 lb DCR=V /Vail= 0.27 < 1 i> }: 1/1 =. EV projects@evengineersnet.com 276-220-0064 ENGINEERS http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf %or Roof with Pv 46.1% Dpv and Racking 3 psf Averarage Total Dead Load 11.4 psf Increase in Dead Load 5.5% OK The increase in seismic Dead weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -ANDREW PERRY.The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments.The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 1/1 4 Sunrun Installation Services Inc. Sunrun Agreement Change Order Andrew Perry 232 Brookside Cir Northampton, MA 01062 Dear Andrew, Thank you for choosing to power your home with clean, solar electricity from Sunrun. An analysis of your solar system has resulted in the following changes to your Sunrun BrightSave customer agreement, dated 4/11/2023: Agreement Key Terms Original Revised Deposit $0 I 1. Initial Payment $0 0 Monthly Payments in Year One [ $243.44 _ I$197.4__3_ Annual Percentage Increase 3.5%0 3.5 A Cost per kWh,Year One — - System Size — — i 1 3-kW-DC L 0.92 kW 15C Year I Production _--- 11-1-,45-6 kWh__ 119,291 kWh Lifetime Production 269,857 kWh 18,858 kWh The revised terms above are a result of the following: Attached you will find a revised Exhibit A to your customer agreement. All revised terms shown above and in Exhibit A hereby supersede and replace the corresponding terms included in your original customer agreement. All other terms and conditions of your original customer agreement remain in full force and effect. SUNRUN INSTALLATION SERVICES INC. 1 225 Bush Street, Suite 1400, San Francisco, CA 94104 1888.GO.SOLAR HIC 180120 Contract Version: 2020Q1 V1 Generation Date: 4/11/2023 Proposal ID: PK4DKC6Z666L:004-H 1 i Please sign and date below to indicate you accept these changes as Amendments to your original customer agreement. If you have any questions please do not hesitate to contact Sunrun at 888.GO.SOLAR Customer Primary Account Holder Sunrun Installation Services Inc.. Initials Signature Signature Andrew Perry Print Name Date Date SUNRUN INSTALLATION SERVICES INC. 1225 Bush Street, Suite 1400, San Francisco, CA 94104 1888.GO.SOLAR HIC 180120 Contract Version: 202001 V1 Generation Date: 4/11/2023 Proposal ID: PK4DKC6Z666L:004-H 2 4 Exhibit A Monthly Payment Schedule and Prepayment Pricing Year Monthly Payment Estimated (including the Annual Prepayment Increase)* Purchase Price^ 1 $197.43 $52,170 72- $204.34 1 $52,018 T-- $211.49 ' $51,776 $218.89 1 $51,439 $226.56 $50,998 6 $234.49 $50,447 7 $242.69 $49,777 8 $251.19 $48,981 9 $259.98 $48,048 10 $269.08 $46,970 11 $278.49 $45,738 12 $288.24 $44,340 13 $298.33 $42,765 14 $308.77 $41,003 15 $319.58 $39,040 16 $330.76 $36,864 17 $342.34 $34,462 18 ' $354.32 $31,818 19 $366.72 $28,919 20 $379.56 $25,747 21 $392.84 $22,287 22 $406.59 $18,520 23 $420.82 $14,428 24 $435.55 $9,991 25 $450.80 $5,189 Year Performance Refund per kWh Guarantee (kWh if Guaranteed Output to Date) Output is Not Met 2 16,682 $0.256 4 ; 33,198 $0.2__ -- 6 49,548 $0.299 8 65,736 $0.324 10 81,762 $0.350 12 , 97,629 $0.379 SUNRUN INSTALLATION SERVICES INC. 1225 Bush Street, Suite 1400, .an Francisco, CA 94104 1888. O.SOLAR HIC 180120 Contract Version:2020Q1 V1 Generation Date: 4/11/2023 Pro.'sal ID: PK4DKC6Z666L:004-H 3 14 ' 113,337 $0.410 16 128,888 $0.444 18 ` 144,285 $0.480 20 159,528 $0.520 22 ' 174,618 $0.562 24 189,558 $0.608 25 196,973 $0.657 * These Monthly Payments assume an Annual Increase of 3.5% ^At any time, you may prepay the balance of your estimated obligations under this Agreement. Please see Section B in you contract for additional information. SUNRUN INSTALLATION SERVICES INC. 1225 Bush Street, Suite 1400, San Francisco, CA 94104 I 888.GO.SOLAR HIC 180120 Contract Version: 2020O1V1 Generation Date: 4/11/2023 Proposal ID: PK4DKC6Z666L:004-H 4 My Custom Solar Design Prepared by Evan Young, 04/11/2023 My Information '�' Andrew Perry ti;. 232 Brookside Cir Northampton, MA 01062 - ,�` A ,_ ¢, System / j Annual Usage 10,924 kWh , I Estimated System Size 10.92 kWp `„, � • Estimated Annual System Production 9,291 kWh #• . ti Estimated Energy Offset 86% Modules (28)Trina Solar,TSM-390DE09C.07 ,�'' `! Inverters 1 x SolarEdge Technologies <y- k � " 4 SE7600H USSN h. 0 Lieutncai Panel Location(Garage)•Inverter Location(Exterior)Roofs Approval I have reviewed My Custom Solar Design and approve of the placement of solar panels identified above. I understand that the actual number of panels and their precise placement may vary based on engineering, installation,and solar energy production considerations, including roof type, shade, and other factors. \sly \d1`•, Customer Signature Date t DocuSign Envelope ID.435A0E6D-71 EF-4D49-97EB-3244CB46A74C Sunrun BrightSaveTM Agreement Andrew Perry 232 Brookside Cir, Northampton, MA, 01062 Take Control of Your Electric Bill $0 25 Years $243 $0 .255 Deposit due Agreement Term Length Monthly Bill for Year Year 1 Cost per kWh Today (3.5% annual increase One (plus taxes, if applicable; (excluding upfront in monthly bill) includes $7.50 discount for payment, if any) Auto-Pay enrollment) WE'VE GOT YOU COVERED WITH OUR WORRY-FREE SERVICE R ( D We provide hassle-free We monitor the system We warrant, insure, Selling your home? design, permitting, and to ensure it runs maintain and repair We guarantee the buyer installation. properly. the system. We will qualify to assume also provide a 10- your agreement. year roof warranty. A SOLAR SYSTEM DESIGN FOR YOUR HOME You get a 14.43 kW DC Solar System With 37 Solar Panels and 1 Inverter(s) Which will produce an est. 11,456 kWh in its first year And offset approx.105% of your current, estimated electricity usage YOUR SALES REPRESENTATIVE: Evan Young evan.ybun sunrun.com (8 1) 837-8728 DocuSign Envelope ID:435A0E6D-71EF-4D49-97EB-3244CB46A74C By signing below, you acknowledge that you have reviewed and received a complete copy of the Agreement without any blanks. Such Agreement shall be the complete understanding between the Parties. SUNRUN r a AnpN SERVICES INC. Signaturands 3un..,da B520FF157D9D460._ . Print Name: Andi Jurado Date: 3/19/2023 4 Title: PRO7FC'T OPFRATTONS Federal Employer Identification Number: 26-2841711 IF YOU CHOOSE TO PAY BY CHECK, MAKE CHECKS OUT TO SUNRUN INC. NEVER MAKE A CHECK OUT TO A SALES REPRESENTATIVE. OUR SALES REPRESENTATIVES ARE NOT AUTHORIZED TO RECEIVE CHECKS IN THEIR OWN NAMES. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE TENTH EFFECTIVE DATE. PLEASE REVIEW THE ATTACHED NOTICES OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. Customer ,Pr count Holder Secondary Account Holder(Optional) w1 ` C5S1tylgfnf@ Andrew Perry Signature 3/16/2023 Date Print Name Email Address*: prattemelda@yahoo.com Mailing Address: 232 Brookside Cir Northampton, MA 01062 Phone: (413) 727-4828 Email addresses will be used by Sunrun for officva/correspondence; such as sending monthly bills or other invoices. Sales Consultant By signing be/ow/acknowledge that/am Sunrun accredited that/presented this agreement according to orSarara Code of Conduct, and that/obtained the homeowner's signature on this agreement. �Nuk, 15 g� a �Egn119 c Evan Young Print Name 1035440582 Sunrun ID number Sunrun Installation Services Inc. 1225 Bush Street, Suite 1400, San Francisco, CA 94104 1888.GO.SOLAR I HIC 180120 Contract Version: 202001 V1 Generation Date: 3/16/2023 Proposal ID: PK4DKC6Z666L-H Version 2020Q1 V1 21 4. SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE K DESCRIPTION MI •SYSTEM SIZE:10920W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), PV-1.0 COVER SHEET SERVICE ENTRANCE •MODULES:(28)TRINA SOLAR:TSM-390DE09C.07 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2.0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-4.0 ELECTRICAL SP SUB-PANEL •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PV PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). AC AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. Ii DC DISCONNECT(S) •12.14 AMPS MODULE SHORT CIRCUIT CURRENT. CB IQ COMBINER BOX •18.97 AMPS DEBATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)). •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). ABBREVIATIONS I--1 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE L J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER ® CHIMNEY s u n r u n AVM AZIMUTH COMP COMPOSRION ^^ Man*c.MaRINT Q ATTIC.VENT _ -- - -- -— __ (E) EXISTING = FLUSH ATTIC VENT VICINITY MAP -- _ — #180120 150 PA0DEffEST WIT Acr.coPff,wA ESS ENERGY STORAGE SYSTEM o PVC PIPE VENT , ""'^'sA, .oraa.iav Pwau FAX 0 EXT EXTERIOR ® METAL PIPE VENT �.r", �� ��MW {? CUSTOMER RESIDENCE: INT INTERIOR ( e.v s*rr ANDREW PERRY MSP MAIN SERVICE PANEL ® T-VENT g Northampton M 232 BROOKSIDE CMR, (N) NEW SATELLITE DISH NORTHAMPTON,MA,01082 NTS NOT TO SCALE At� „.EEtt %).?"1114 TEL.(413)727-4828 OC ON CENTER IJ.' 232 Brookside CR, �di APN:NHAMM0036B0118L0001 j FIRE SETBACKS Northampton,MA o PRE-FAB PRE-FABRICATED 01062,United States 7MM /f PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT HARDSCAPE co'''' �' 224R-232PERR a PV PHOTOVOLTAIC -.< , a tar�a,�r 5 v $ 415 580-6920 eX3 RSD RAPID SHUTDOWN DEVICE PL— PROPERTY LINE ..w- DESIGNER. ( ) TL TRANSFORMERLESS SOLAR MODULES • ROWELL CRUZ • • SCALE:NTS '"�• SHEET VP 1 S' + REV NAME DATE COMMENTS COVER SHEET _ • ■ / A VOLTS 8 A ? W WATTS >� MAN LANDSCAPE •i. REV:Al 4/12R023 SNR MOUNT 44.4 T-rs PAGE POR PORTRAIT .• PV-1.0 SNR MOUNT&SKIRT ..e a°'�a TanpaMe ersion_t0.87 SITE PLAN-SCALE-3/84"=V-0" 7 R e� 7 R vs- FNN..> IRE SETBACKS / 4" (3'lYP) Q" ROOF PATHWAYS (3'TYP) ev a- (E)RESIDENCE 7 ��MP ( 11:1F11111 ��` `�` sunrun NOTES: 4 --. :A.-.''— RESIDENCE DOES NOT CONTAIN ACTIVE FIRE •♦''_' SPRINKLERS. ♦ '=_�.�' / ARRAY DETAILS: #180120 • TOTAL ROOF SURFACE AREA:1258 SOFT. ♦ .PPOC£TE ST UNIT.CHICOPEE.M..010Y1-13J3 ° ♦ • TOTAL PV ARRAY AREA:579.4 SQ FT. PHONE 0 • PERCENTAGE PV COVERAGE: FM 4 a ROOF PATHWAYS (TOTAL PV ARRAY AREA/TOTAL ROOF SURFACE CUSTOMER RESIDENCE: , (3'TYP) AREA)•100=46.1% ANDREW PERRY O 232 BROOKSIDE CIR, �S�Q (N)ARRAY AR-02 NORTHAMPTON,MA,01062 O�"P. TEL.(413)727-4828 ARRAY TRUE MAG PV AREA ? 4V PITCH AZIM AZIM (SOFT) APN:NHAMM0036B01 1 610 001 (N)ARRAY AR-01 AR-01 18° 229' 243' 351.8 224R-232PERR AR-02 18' 49' 63' 227.E PROJECT NUMBER: DESIGNER: (415)5806920 ex3 ROWELL CRUZ ? r \\ V SHEET SITE PLAN REV:Al 4/12/2023 PAGE PV-2 0 Temp'ero ro 08 1087 f Ilt ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Name Type Height Type Max OC Detail Max Landscape Max Landscape Max Portrait Max Portrait Configuration MAX DISTRIBUTED LOAD:3 PSF Span SpacingOC Spacing Overhang OC Spacing Overhang SNOW LOAD:40 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X4 CARPENTER TRUSSES 6'-4" 16" COMP,SEE DETAIL SNR-DC-00436 NA NA STAGGERED 117 MPH 3-SEC GUST. S.S.LAG SCREW AR-02 COMP SHINGLE-RLU 1-Story 2X4 CARPENTER TRUSSES 6'-8" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON NA NA STAGGERED 5/16":2.5"MIN.EMBEDMENT COMP,SEE DETAIL SNR-DC-00436 D1-AR-01-SCALE:1/8"=1'-0" AZIM:229° PITCH:18° INSTALLERS SHALL NOTIFY ENGINEER OF ANY }-3'- 34'-10" —5'-2"—{ POTENTIAL STRUCTURAL ISSUES OBSERVED PRIOR TO PROCEEDING W/INSTALLATION. IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12" rap�i ��4/�/.�imz (firm 3 BOUNDARY OF AY EDGES(EXCEPTION VVALLLEYS"THENF PLANE � ATTACHMENTS NEED O BE ADDEDH AND OVERHANG REDUCED WITHIN THE 12" 7'-3" BOUNDARY REGION ONLY AS FOLLOWS: **ALLOWABLE ATTACHMENT SPACING 10 11 � _ � I INDICATEDED BY ALLOWABLE OVERHANG INDICATED ON50%. / PLANS TO BE 1/5TH OF ALLOWABLE 4'I2" ATTACHMENT SPACING INDICATED ON PLANS. 6", 29' 11' i D2-AR-02-SCALE:3/16"=1'-0" AZIM:49" s u n r u n PITCH:18' I}III 4'-3"—, 34'-10" ,-3'-11"— I/ STRUCT // //// /// / / /// /� ONL of #080120 1/ 3. ob, la M44.4,o ' a i-' ❑ ,E(/ I ��� VINCENT c,YG� nocErrs s.urur A.cwcorse.MA.a1oa.1; c MWUMVANEZA , CIVIL CUSTOMER RESIDENCE: / o e 232 ANDREW PERRY ❑ ❑ 0 0 C n 0 O E3 7'-3" '%"' E0.��\x''� 232 BROOKSIDE CIR, / EN NORTHAMPTON,MA,01062 O -5'-4"TYP—I Signed 4/12/2023 TEL.(413)7274828 n Cl n n r n n n n s APN:NHAMM003660118L0001 / O I PROJECT NUMBER: / 4'-2" 224R-232PERR DESIGNER: (415)580-6920 ex3 ROWELL CRUZ SHEET LAYOUT REV:Al 4/12/2023 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 ThMWW°h wnion_to.a7 120/240 VAC SINGLE PHASE SERVICE METER#: NOTE:TOTAL PV BACKFEED=40A - O NATIONAL GRID 14891222 USED FOR INTERCONNECTION UTILITY CALCULATIONS GRID I SUPPLY SIDE TAP (I EXISTING 200A (N)LOCKABLE BLADE TYPE MAIN BREAKER FUSED AC (N)LOCKABLE SOLAREDGE TECHNOLOGIES: t DISCONNECT BLADE TYPE SE7600H-USSN I AC DISCONNECT 7600 WATT INVERTER JUNCTION BOX PV MODULES i--.' n n OR EQUIVALENT 9 TRINA SOLAR:TSM-390DE09C.07 �. EXISTING AAAV 9 _ FV �� / (28)MODULES �� 200A MAINo.o. • o.- e I _ .—.� --«- V1 i t// OPTIMIZERS WIRED IN: L FACILITY -* '' --- (1)SERIES OF(13)OPTIMIZERS LOADS 40A FUSES - ' I e I (1)SERIES OF(15)OPTIMIZERS 1 dA; SQUARE D SQUARE D LOAD RATED DC DISCONNECT D222NRB DU222RB WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A 3R,60A,2P COMPLIANT S440 120/240VAC 120/240VAC CONDUIT SCHEDULE TAP DEVICE MUST BE MARKED"SUITABLE # CONDUIT CONDUCTOR NEUTRAL GROUND FOR USE ON THE LINE SIDE OF THE SERVICE EQUIPMENT'OR EQUIVALENT 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n ru n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 150 PACGETE Si WR A CMCOGEE.51A.01021.1133 SHOW 0 FAX 0 MODULE CHARACTERISTICS S440 OPTIMIZER CHARACTERISTICS: TRINA SOLAR:TSM-390DE09C.07: 390 W CUSTOMER RESIDENCE MIN INPUT VOLTAGE: 8 VDC OPEN CIRCUIT VOLTAGE: 40.8 V ANDREW PERRY MAX INPUT VOLTAGE: 60 VDC MAX POWER VOLTAGE: 33.8 V MAX INPUT ISC: 14.5 ADC 232 BROOKSIDE CIR, SHORT CIRCUIT CURRENT: 12.14 A NORTHAMPTON,MA,01062 MAX OUTPUT CURRENT: 15 ADC TEL.(413)727-4828 SYSTEM CHARACTERISTICS-INVERTER 1 APN:NHAMM003680118L0001 SYSTEM SIZE: 10920 W PROJECT NUMBER. SYSTEM OPEN CIRCUIT VOLTAGE: 15 V 224R-232PERR SYSTEM OPERATING VOLTAGE 400 V MAX ALLOWABLE DC VOLTAGE: 480 V DESIGNER: (415)580-6920 ex. SYSTEM OPERATING CURRENT: 27.3 A ROWELL CRUZ SYSTEM SHORT CIRCUIT CURRENT: 30 A SHEET ELECTRICAL REV:Al 4/12/2023 PAGE PV-4.0 r.mp,r._wlson 40.87 I r INVERTER 1 NOTES AND SPECIFICATIONS: •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT F 110.21(B).REQUESTEDUNLESS BY THE SPECIFIC INS STRUCTIONS ARE REQUIRED BY SECTION 890,OR IMAXIMUM SYSTEM VOLTAGE: as0 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:690.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY VMTH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERVNSE SPECIFIED. AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 705.20(7),706.15(C) • I: ,G DUAL POWER SUPPLY SOURCES:UTILITY GRID WARNING: PHOTOVOLTAIC AND PV SOLAR ELECTRIC POWER SOURCE SYSTEM LABEL LOCATION: LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, CAUTION : UTIUTY SERVICE METER AND MAIN AT EACH TURN,ABOVE AND BELOW PENETRATIONS. SERVICE PANEL. ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:705.30(C) PER CODE(S):NEC 2023:690.31(0)(2) ;I .t� .' .Y ` RAPID SHUTDOWN SWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS III OVERCURRENT DEVICE II 111 LABEL LOCATION. ADJACENT LOCATION:ON: INSTALLED WITHIN(3')NECF 2ID 02SHUT DOWN 11111 s u n r u n ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NE 2023:690.12(D)(2),IFC OCPD OF APPUCABLE). 2018:1204.5.3 ,,, SOLAR PANELSPER CODE(S):NEC 2023:705.12(8)(2) , ,,, ON ROOF T�. � uui #1B0120 THIS EQUIPMENT FED BY r. 1111111! MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN `% O RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE ANDREW PERRY SHALL NOT EXCEED AMPACITY OF INVERTER (EXT) 232 BROOKSIDE CIR, BUSBAR MAIN PANEL(INT) NORTHAMPTON,MA,01062 LABEL LOCATION: 3" TURN RAPID SHUTDOWN FUSED AC DISCONNECT PV LOAD CENTER(IF APPUCABLE)AND SWITCH TO THE"OFF" TEL.(413)727-4828 ANY PANEL THAT UTILIZES"THE SUM POSITION TO SHUT DOWN AC DISCONNECT APN:NHAMM0036B0118L0001 OF BREAKERS RULE". PV SYSTEM AND REDUCE PER CODE(S):NEC 2023:705.12(B)(3) SHOCK HAZARD IN THE SERVICE ENTRANCE PROJECT NUMBER: i 224R-232PERR . PV SYSTEM DISCONNECT ARRAY DESIGNER. (415)560-6920 eu3 MAXIMUM AC OPERATING CURRENT:42.00 AMPS ROWELL CRU2 NOMINAL OPERATING AC VOLTAGE: 240 VAC 232 BROOKSIDE CIR, NORTHAMPTON, MA, 0106E SHEET LABEL LOCATION LABEL LOCATION: SIG NAG E AC DISCONNECT(S).PHOTOVOLTAIC SYSTEM POINT OF ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2023:705.10(2) INTERCONNECTION. DISCONNECTING MEANS TO WHICH THE PV SYSTEMS PER CODE(S):NEC 2023:690.54 ARE CONNECTED. REV:Al 4/12/2023 PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.0 u ib]