Packaged Vetrical MASUPPLY AIRRETURN AIRs ACCESSPANEL CONDENSATE TO APPROVED PUMP OR DRAINPER AHJ (TRAP REQUIRED) NOTES: •LEFT SIDE RETURN SHOWN. UNIT CAN BE CONFIGURED FOR EITHER LEFT- OR RIGHT-HAND RETURN. CONNECTIONS MIRRORED FOR RIGHT HAND CONFIGURATION. •APPROVED INTERIOR PIPING MATERIALS: HDPE, PEX AND/OR RUBBER HEATER HOSE. REFER TO DANDELION'S DESIGN &INSTALLATION STANDARDS FOR SIZING REQUIREMENTS. •SUPPLY-RETURN LINE SIZES SELECTED PER DANDELION'S DESIGN AND INSTALLATION STANDARDS. •ALL INTERIOR PIPING INSULATED WITH CLOSED-CELL INSULATION (12 MIN. THICKNESS).•TARGET DEPTH FOR BUILDING ENTRY POINT IS 4 FT BELOW GRADE. REFER TO DANDELION'S DESIGN AND INSTALLATION STANDARDS FOR PROVISIONS WHEN EXCEPTIONS OCCUR. •THE USE OF CHECK VALVES IS REQUIRED WHEN MULTIPLE HEAT PUMPS ARE CONNECTED TO A COMMON (SHARED) GROUND LOOP. •SEE SHEETS 2, 3, AND 4 (OF 4) FOR ADDITIONAL DANDELION SYSTEM REQUIREMENTS. ROUGH GRADE ACCESSPANEL PROJECT NAME: PROJECT ID: PROJECT ADDRESS: DATE: PAGE: 1 OF 4 DESCRIPTION: SCALE: NTS SIZE: ISO_B_11 X 17VERSION V2021.08 CONTRACTOR NAME: INTERIOR PIPING (DANDELION YT) MULTI-POSITION VERTICAL PACKAGED LEGEND AIR SEPARATOR BALL VALVE-MANUAL DRAIN VALVE-MANUAL FLEXIBLE PIPINGCONNECTION 90 ELBOW WITH PT/SENSOR PORT TEE CONNECTION-GENERALPIPING PIPING, TUBING,HOSE-GENERAL COUPLING-MALE xFEMALE EXPANSION TANK s DANDELION AIR OPERATION LIMITS PARAMETER COOLING HEATING MIN EAT 60°F 45°F MAX EAT 100°F 80°F MIN EWT 30°F 20°F MAX EWT 110°F 90°F MIN WATER FLOW 2.5 GPM/TON MAX WATER FLOW 3.5 GPM/TON MIN AIR FLOW 300 CFM/TON SYSTEM PRESSURIZATION DETAILS RANGE MIN.MAX. START-UP PRESSURE 30 PSI 60 PSI U-BEND QTY AND PIPE SIZEPER DESIGN DOCUMENTSLOOP SUPPLY (FROM BUILDING) HEADER PIPE SIZE PER DESIGN DOCUMENTS LOOP RETURN (TO BUILDING) HEADER PIPE SIZE PERDESIGN DOCUMENTS STEP-DOWN, STEP-UPREVERSE-RETURN HEADER(PER D&I STANDARDS)VERTICAL BOREHOLE (QTY ANDSPACING PER DESIGN DOCUMENTS) STEP-DOWN, STEP-UPREVERSE RETURN HEADER PROJECT NAME: PROJECT ID: PROJECT ADDRESS: DATE: PAGE: 2 OF 4 DESCRIPTION: SCALE: NTS SIZE: ISO_B_11 X 17VERSION V2021.08 CONTRACTOR NAME: GROUND LOOP AND HEADER PIPING SYSTEM ANTIFREEZE MUST MEET OR EXCEED AHJ BUILDING CODES CORRESPOND WITH FREEZE POINT 12-13⁰F BELOW MIN EWT ANTIFREEZE CONCENTRATION % BY VOLUME ANTIFREEZE TYPE MIN EWT (⁰F) 25⁰F 30⁰F 35⁰F - 45⁰F > 45⁰F PROPYLENE GLYCOL 28% 22% 20%0% ETHANOL 25% 20% 15%0% METHANOL DO NOT USE 15% 10%0% HEAT TRANSFER FLUID MUST COMPLY WITH ANSI/CSA/IGSHPA C448.0-16,SECTION 5.7 • • • • • • • • • • PROJECT NAME: PROJECT ID: PROJECT ADDRESS: DATE: PAGE: 3 OF 4 DESCRIPTION: SCALE: NTS SIZE: ISO_B_11 X 17 HEAT PUMP WATER HEATER INSTALLATION DETAILS (ALL MODELS) VERSION V2021.08 CONTRACTOR NAME: COLD WATER SUPPLY HOT WATERSUPPLY (TO HOUSE) DRAIN NOTES: •DOMESTIC HOT WATER CONNECTIONS SHALL MEET OR EXCEED ALL APPLICABLE BUILDING CODES.•TEMPERATURE AND PRESSURE RELIEF VALVE (TPV) SHALL BE FACTORY INSTALLED AND TERMINATED ACCORDING TO APPLICABLE BUILDING CODES •ALL NEW PLUMBING Ø12 IN. (MIN.), PEX OR COPPER •THE NEW WATER HEATER SHALL TIE-INTO THE EXISTING DOMESTIC WATER PLUMBING.•SEE SHEETS 1, 2, AND 4 (OF 4) FOR ADDITIONAL DANDELION SYSTEM REQUIREMENTS. (NEW) HEAT PUMPWATER HEATER LEGEND BALL VALVE-MANUAL DRAIN VALVE-MANUAL PIPING, TUBING, HOSE-GENERAL HOT WATER LINE COLD WATER LINE CONDENSATE TOAPPROVED DRAIN PER AHJ PROJECT NAME: PROJECT ID: PROJECT ADDRESS: DATE: PAGE: 4 OF 4 DESCRIPTION: SCALE: NTS SIZE: ISO_B_11 X 17 ELECTRICAL/THERMOSTAT/CONDENSATE PUMP WIRING (DANDELION YT) MULTI-POSITION VERTICAL PACKAGED VERSION V2021.08 CONTRACTOR NAME: ECOBEE THERMOSTAT (NEW) NOTES: •ELECTRICAL WORK MUST MEET OR EXCEED ALL APPLICABLE BUILDING & ELECTRICAL CODES•WHEN THE DISTANCE FROM THE SERVICE PANEL TO THE HEAT PUMP IS GREATER THAN 100 FT, CONSULT WITH THE ENGINEERING TEAMFOR FURTHER REVIEW. •SEE SHEETS 1, 2, AND 3 (OF 4) FOR ADDITIONAL DANDELION SYSTEMREQUIREMENTS. (NEW) HEAT PUMP ELECTRICAL PANELREFER TO TABLE FOR BREAKER REQUIREMENTS (EXISTING) MAIN ELECTRICAL PANEL G G L L L L Rc R G Y 1 Y 2 COM O DH W 1 HEAT PUMP THERMOSTATTERMINAL BLOCK CONDENSATE PUMP BREAK (C) WIRE IF CONDENSATE BACKS UP OR MALFUNCTIONS HEAT PUMP AUX HEATER G Y1 Y2 O/B PEK Rh C W1 W2 ACC- ACC+