[21-010-0556, Feiden] Dandelion Project Plan (1)DESCRIPTION:
SITE PLAN
PAGE:
SCALE: SEE NTS SIZE: ISO_B_11X17
1 of 4
CONTRACTOR NAME:PROJECT NAME:
Feiden, Wayne
PROJECT ADDRESS:
57 Olander Dr, Northampton, MA 01060, USA
VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING
AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON,
UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS
DRAWING IN ANY WAY.
BORE 1
DRILL RIG ACCESS POINT
D R I L L R I G A CC ESS P O I NT
HEADER
ELECT & COMM
WATER SUPPLY
GAS/FUEL PIPE
WASTE / SEWER
DESCRIPTION:
DETAILED SITE PLAN
PAGE:
SCALE: SEE NTS SIZE: ISO_B_11X17
2 of 4
ID
TYPE
NO. OF BORES
BORE DEPTH
BORE SPACING
EST. DEPTH TO BEDROCK
U-BEND DIAMETER
U-BEND MATERIAL
GROUT CONDUCTIVITY
HEADER DIAMETER
HEADER MATERIAL
EST. TRENCH LENGTH
TIE-IN TYPE
LOOP 1
VERTICAL BORE
1
359
18 FT
61.02 FT
1-1/4 IN
HDPE 4710 DR-11
1.2 BTU/HR-FT-F
1-1/2 IN
HDPE 4710 DR-11
56 FT
BELOW GROUND NHOMEOWNER OBLIGATIONS & EXCLUSIONS
-Remove fence
-Remove walkway
-Remove pavers
DESIGN NOTES FOR DRILLING:
-None
DESIGN NOTES FOR TRENCHING:
-None
CONTRACTOR NAME:PROJECT NAME:
Feiden, Wayne
PROJECT ADDRESS:
57 Olander Dr, Northampton, MA 01060, USA
VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING
AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON,
UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS
DRAWING IN ANY WAY.BORE 1HEADER
ELECT & COMM
WATER SUPPLY
WASTE / SEWER
GAS/FUEL PIPE DRILL RIG ACCESS10'25'
EXISTING EQUIPMENT TO BE REMOVED:
N
DESCRIPTION:
EQUIPMENT REMOVAL PLAN
PAGE:
SCALE: SEE NTS SIZE: ISO_B_11X17
3 of 4
EXISTING EQUIPMENT TO BE REMAIN IN PLACE:
PROPOSED BREAKERS TO REMOVE:
-MSP: 11, 13 and 15
HOMEOWNER OBLIGATIONS & EXCLUSIONS:
-None
DESIGN NOTES FOR INSTALLERS:
-None BASEMENT
CONTRACTOR NAME:PROJECT NAME:
Feiden, Wayne
PROJECT ADDRESS:
57 Olander Dr, Northampton, MA 01060, USA
VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING
AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON,
UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS
DRAWING IN ANY WAY.
MSP1 - MAIN SERVICE PANEL
SERVICE RATING 200A
BRAND MURRAY
F1 - FURNACE
FUEL TYPE:NATURL GAS
AC1 - AC CONDENSER
REFRIG. TYPE:R-410a
WH1 - WATER HEATER
SIZE 50 GAL
FUEL TYPE NATURL GAS
PIPING 1"COPPER
WH1
REMOVE F1
REMOVEMSP1
AC1
REMOVE
E
Q
U
I
P
M
E
N
T P
A
T
H
NEW EQUIPMENT TO BE INSTALLED:
DESCRIPTION:
NEW EQUIPMENT PLAN
PAGE:
SCALE: SEE NTS SIZE: ISO_B_11X17
4 of 4
N
BASEMENT
DUCTWORK MODIFICATION DETAILED INSTRUCTIONS:
-None
HOMEOWNER OBLIGATIONS & EXCLUSIONS:
-Remove and repair drywall
DESIGN NOTES FOR INSTALLERS:
-None
LOOP 1 GROUND LOOP TIE-IN
25 FT FROM NW CORNER
1-1/2 IN HDPE
20 GAL OF GLYCOL
ID
EQUIPMENT
BRAND
SIZE
DISTRIBUTION
AIRFLOW: HTG/CLG
SUPPLY
RETURN
ELECTRICAL
AUX HEAT
ELECT DISCO REQD
DESUPERHEATER
THERMOSTAT
TSTAT WIRES
CONDITIONED AREA
DUCT ZONING
AEROSEAL Y/N
GROUND LOOP
CONTRACTOR NAME:PROJECT NAME:
Feiden, Wayne
PROJECT ADDRESS:
57 Olander Dr, Northampton, MA 01060, USA
VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING
AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON,
UNLESS ACTING UNDER THE DIRECTION OF A LICENSED
PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS
DRAWING IN ANY WAY.
HP1
NEW
EQUIPMENT PATHWH1
NEWMSP1
ID
EQUIPMENT
BRAND
SIZE
ELECTRICAL
ELECT DISCO REQD
PIPING
WH1
HEAT PUMP WATER HEATER
AO SMITH
80 GAL
30A - 240VAC
YES
1 IN PEX
HP1
PACKAGE HEAT PUMP
ENERTECH YT
3 TON
FORCED AIR
1,380 CFM / 1,420 CFM
VERTICAL
MULTIPOSITION
40A - 240VAC
YES, 60A - 240VAC
YES
NO
ECOBEE
EXISTING 4, 6 WIRE
WHOLE HOUSE
YES, 2 ZONES
NO
LOOP 1