Loading...
[21-010-0556, Feiden] Dandelion Project Plan (1)DESCRIPTION: SITE PLAN PAGE: SCALE: SEE NTS SIZE: ISO_B_11X17 1 of 4 CONTRACTOR NAME:PROJECT NAME: Feiden, Wayne PROJECT ADDRESS: 57 Olander Dr, Northampton, MA 01060, USA VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS DRAWING IN ANY WAY. BORE 1 DRILL RIG ACCESS POINT D R I L L R I G A CC ESS P O I NT HEADER ELECT & COMM WATER SUPPLY GAS/FUEL PIPE WASTE / SEWER DESCRIPTION: DETAILED SITE PLAN PAGE: SCALE: SEE NTS SIZE: ISO_B_11X17 2 of 4 ID TYPE NO. OF BORES BORE DEPTH BORE SPACING EST. DEPTH TO BEDROCK U-BEND DIAMETER U-BEND MATERIAL GROUT CONDUCTIVITY HEADER DIAMETER HEADER MATERIAL EST. TRENCH LENGTH TIE-IN TYPE LOOP 1 VERTICAL BORE 1 359 18 FT 61.02 FT 1-1/4 IN HDPE 4710 DR-11 1.2 BTU/HR-FT-F 1-1/2 IN HDPE 4710 DR-11 56 FT BELOW GROUND NHOMEOWNER OBLIGATIONS & EXCLUSIONS -Remove fence -Remove walkway -Remove pavers DESIGN NOTES FOR DRILLING: -None DESIGN NOTES FOR TRENCHING: -None CONTRACTOR NAME:PROJECT NAME: Feiden, Wayne PROJECT ADDRESS: 57 Olander Dr, Northampton, MA 01060, USA VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS DRAWING IN ANY WAY.BORE 1HEADER ELECT & COMM WATER SUPPLY WASTE / SEWER GAS/FUEL PIPE DRILL RIG ACCESS10'25' EXISTING EQUIPMENT TO BE REMOVED: N DESCRIPTION: EQUIPMENT REMOVAL PLAN PAGE: SCALE: SEE NTS SIZE: ISO_B_11X17 3 of 4 EXISTING EQUIPMENT TO BE REMAIN IN PLACE: PROPOSED BREAKERS TO REMOVE: -MSP: 11, 13 and 15 HOMEOWNER OBLIGATIONS & EXCLUSIONS: -None DESIGN NOTES FOR INSTALLERS: -None BASEMENT CONTRACTOR NAME:PROJECT NAME: Feiden, Wayne PROJECT ADDRESS: 57 Olander Dr, Northampton, MA 01060, USA VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS DRAWING IN ANY WAY. MSP1 - MAIN SERVICE PANEL SERVICE RATING 200A BRAND MURRAY F1 - FURNACE FUEL TYPE:NATURL GAS AC1 - AC CONDENSER REFRIG. TYPE:R-410a WH1 - WATER HEATER SIZE 50 GAL FUEL TYPE NATURL GAS PIPING 1"COPPER WH1 REMOVE F1 REMOVEMSP1 AC1 REMOVE E Q U I P M E N T P A T H NEW EQUIPMENT TO BE INSTALLED: DESCRIPTION: NEW EQUIPMENT PLAN PAGE: SCALE: SEE NTS SIZE: ISO_B_11X17 4 of 4 N BASEMENT DUCTWORK MODIFICATION DETAILED INSTRUCTIONS: -None HOMEOWNER OBLIGATIONS & EXCLUSIONS: -Remove and repair drywall DESIGN NOTES FOR INSTALLERS: -None LOOP 1 GROUND LOOP TIE-IN 25 FT FROM NW CORNER 1-1/2 IN HDPE 20 GAL OF GLYCOL ID EQUIPMENT BRAND SIZE DISTRIBUTION AIRFLOW: HTG/CLG SUPPLY RETURN ELECTRICAL AUX HEAT ELECT DISCO REQD DESUPERHEATER THERMOSTAT TSTAT WIRES CONDITIONED AREA DUCT ZONING AEROSEAL Y/N GROUND LOOP CONTRACTOR NAME:PROJECT NAME: Feiden, Wayne PROJECT ADDRESS: 57 Olander Dr, Northampton, MA 01060, USA VERSION V2021.11 PROJECT ID:21-010-0556 DATE:2022-03-27DRAWN BY:AA IN ACCORDANCE WITH ARTICLE 145, PROFESSIONAL ENGINEERING AND LAND SURVEYING 7209 (2), IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER OR LAND SURVEYOR, TO ALTER THIS DRAWING IN ANY WAY. HP1 NEW EQUIPMENT PATHWH1 NEWMSP1 ID EQUIPMENT BRAND SIZE ELECTRICAL ELECT DISCO REQD PIPING WH1 HEAT PUMP WATER HEATER AO SMITH 80 GAL 30A - 240VAC YES 1 IN PEX HP1 PACKAGE HEAT PUMP ENERTECH YT 3 TON FORCED AIR 1,380 CFM / 1,420 CFM VERTICAL MULTIPOSITION 40A - 240VAC YES, 60A - 240VAC YES NO ECOBEE EXISTING 4, 6 WIRE WHOLE HOUSE YES, 2 ZONES NO LOOP 1