[21-010-0556 Wayne Feiden] Heat Load2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 1...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Building Analysis Date:Entire House By: Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com Project Information Wayne FeidenFor:57 Olander Dr, Northampton, MA 01060 Design Conditions Location: CoolingHeatingIndoor:7272Indoor temperature (°F)Westover Metro, MA, US 1666Design TD (°F)ft241Elevation:5030Relative humidity (%)°N42Latitude:Outdoor:31.229.3Moisture difference (gr/lb)CoolingHeating Infiltration:886Dry bulb (°F) SimplifiedMethod)M(22-Daily range (°F)Semi-tightConstruction quality71-Wet bulb (°F)1 (Semi-tight)Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 32.096305.4Walls 15.8476021.1Glazing 3.6108825.9Doors 7.923632.1Ceilings 4.212571.11.1Floors 23.269903.7Infiltration 6.11826Ducts00Piping00Humidification7.22172Ventilation0Adjustments100.030086Total Cooling Walls Glazing Doors Ceilings Floors Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 17.424071.3Walls 32.1444119.7Glazing 3.142710.2Doors 12.717641.6Ceilings 2.02780.2Floors 5.57570.4Infiltration 4.1567Ducts3.7514Ventilation19.42690Internal gains 00Blower0Adjustments100.013844Total Latent Cooling Load = 2976 BtuhOverall U-value = 0.072 Btuh/ft²-°F Data entries checked. 2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 2...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Building Analysis Date:1st Floor By: Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com Project Information Wayne FeidenFor:57 Olander Dr, Northampton, MA 01060 Design Conditions Location: CoolingHeatingIndoor:7272Indoor temperature (°F)Westover Metro, MA, US 1666Design TD (°F)ft241Elevation:5030Relative humidity (%)°N42Latitude:Outdoor:31.229.3Moisture difference (gr/lb)CoolingHeating Infiltration:886Dry bulb (°F) SimplifiedMethod)M(22-Daily range (°F)Semi-tightConstruction quality71-Wet bulb (°F)1 (Semi-tight)Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 32.855946.2Walls 19.6334023.3Glazing 6.4108825.9Doors 4.37252.1Ceilings 6.210491.01.0Floors 20.134183.7Infiltration 10.71826Ducts00Piping00Humidification00Ventilation0Adjustments100.017041Total Cooling Walls Glazing Doors Ceilings Floors Infiltration Ducts Internal Gains % of loadBtuhBtuh/ft²Component 14.613771.5Walls 40.3379026.4Glazing 4.542710.2Doors 5.85411.6Ceilings 2.62480.2Floors 3.93700.4Infiltration 6.9652Ducts00Ventilation21.32000Internal gains 00Blower0Adjustments100.09405Total Latent Cooling Load = 1271 BtuhOverall U-value = 0.079 Btuh/ft²-°F Data entries checked. 2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 3...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Building Analysis Date:2nd Floor By: Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com Project Information Wayne FeidenFor:57 Olander Dr, Northampton, MA 01060 Design Conditions Location: CoolingHeatingIndoor:7272Indoor temperature (°F)Westover Metro, MA, US 1666Design TD (°F)ft241Elevation:5030Relative humidity (%)°N42Latitude:Outdoor:31.229.3Moisture difference (gr/lb)CoolingHeating Infiltration:886Dry bulb (°F) SimplifiedMethod)M(22-Daily range (°F)Semi-tightConstruction quality71-Wet bulb (°F)1 (Semi-tight)Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Other Infiltration % of loadBtuhBtuh/ft²Component 37.140354.5Walls 13.1142017.3Glazing 000Doors15.116382.1Ceilings 1.92085.25.2Floors 32.835723.7Infiltration 00Ducts00Piping00Humidification00Ventilation0Adjustments100.010874Total Cooling Walls Glazing Ceilings Other Infiltration Internal Gains % of loadBtuhBtuh/ft²Component 18.110301.2Walls 40.9232728.3Glazing 000Doors21.512221.6Ceilings 0.5300.7Floors 6.83870.4Infiltration 00Ducts00Ventilation12.1690Internal gains 00Blower0Adjustments100.05686Total Latent Cooling Load = 1075 BtuhOverall U-value = 0.062 Btuh/ft²-°F Data entries checked. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 1...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Right-J8® Form J1 Date:Entire House By:Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com 1 Name of Room Entire House 1st Floor 2 Running Feet of Exposed Wall 258.0 ft 136.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²2197.0ft 8.0 ft²1221.0ft 4 Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²1842.8 ft²1072.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²1842.8°0 ft²1072.0° Type ofExposure Const.,NumberType ofExposure Const.,Number PanelFaces HTMPanelFacesHTM Area orLength BtuhArea orLength Btuh Area orLength BtuhArea orLength Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12E-0sw12E-0sw nn 4.524.52 1.151.15 564 2214 565 288 967 247.GlazGlaz 1D-c2ovd1D-c2ovd nn 37.8537.85 19.6519.65 42 1590 825 42 1590 825.GlazGlaz 2 glazing, clr outr, n2 glazing, clr outr, n 17.2617.26 8.868.86 32 548 281 32 548 281.WallWall 12E-0sw12E-0sw ee 4.524.52 1.151.15 314 1299 332 102 461 11811GlazGlaz2 glazing, clr outr, e2 glazing, clr outr, e 17.2617.26 27.5527.55 26 453 723 0 0 0WallWall12E-0sw12E-0sw ss 4.524.52 1.151.15 564 2242 572 288 1148 293GlazGlaz2 glazing, clr outr, s2 glazing, clr outr, s 17.2617.26 14.9614.96 68 1166 1011 34 584 506WallWall12E-0sw12E-0sw ww 4.524.52 1.151.15 468 1756 448 256 899 230 GlazGlaz 2 glazing, clr outr, w2 glazing, clr outr, w 17.2617.26 27.5527.55 58 1003 1601 36 619 988DoorDoor11D011D0ww25.9025.90 10.1610.16 21 544 213 21 544 213 WallWall 12A-0sw12A-0sw --15.9415.94 3.683.68 154 2119 490 154 2119 490DoorDoor11D011D0nn25.9025.90 10.1610.16 21 544 213 21 544 213CeilCeil16B-30ad16B-30ad --2.122.12 1.591.59 1112 2363 1764 341 725 541FlorFlor19C-30bswp19C-30bswp --0.980.98 0.230.23 1072 1049 248 1072 1049 248FlorFlor20P-11w20P-11w --5.185.18 0.740.74 40 208 30 0 0 0 Infiltration Heating Load (Btuh)0.390.39 6990 3418EffectWARWAR12Sensible Load (Btuh)ACH 1.00 757 1.00 3700.180.18 Latent Load (Btuh)929 454 Internal a Occupants at 230 and 200 Btuh 3 690 600 0 0 0 b Scenario number 2000 200013cDefault Adjustments d Custom Appliances 0 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 26088 12764 1529 15215 8754 454 Duct EHLF & ESGF 0.1200.070 0.0740.045 1826 567 1826 65215LoadsELG816 816 Vent CfmVent Cfm16Ventilation Loads 6060 E CfmE Cfm 6060 2172 514 630 0 0 0 17 Winter Humidification Load Gal/Day 00 0 0 18 Piping Load 0 0 19 Blower Heat 0 0 20 AED Excursion & Latent Moisture Migration Load 0 1190 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 30086 13844 2976 17041 9405 1271 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 2...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Right-J8® Form J1 Date:Entire House By:Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com 1 Name of Room 2nd Floor 2 Running Feet of Exposed Wall 122.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²976.0ft 4 Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²770.85Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²770.8° Type ofExposure Const.,Number PanelFaces HTM Area orLength Btuh Area orLength Btuh Htg.Clg.Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12E-0sw n 4.52 1.15 276 1246 318.Glaz 1D-c2ovd n 37.85 19.65 0 0 0.Glaz 2 glazing, clr outr, n 17.26 8.86 0 0 0.Wall 12E-0sw e 4.52 1.15 212 839 21411Glaz2 glazing, clr outr, e 17.26 27.55 26 453 723Wall12E-0sw s 4.52 1.15 276 1094 279Glaz2 glazing, clr outr, s 17.26 14.96 34 583 505Wall12E-0sw w 4.52 1.15 212 857 219 Glaz 2 glazing, clr outr, w 17.26 27.55 22 384 613Door11D0w25.90 10.16 0 0 0 Wall 12A-0sw -15.94 3.68 0 0 0Door11D0n25.90 10.16 0 0 0Ceil16B-30ad -2.12 1.59 771 1638 1222Flor19C-30bswp -0.98 0.23 0 0 0Flor20P-11w -5.18 0.74 40 208 30 Infiltration Heating Load (Btuh)0.39 3572EffectWAR12Sensible Load (Btuh)ACH 1.00 3870.18 Latent Load (Btuh)475 Internal a Occupants at 230 and 200 Btuh 3 690 600 b Scenario number 013cDefault Adjustments d Custom Appliances 0 0ePlants0 14 Subtotals Sum lines 6 through 12 10874 5686 1075 Duct EHLF & ESGF 0 0 0 015LoadsELG 0 Vent Cfm16Ventilation Loads 60 E Cfm 60 0 0 0 17 Winter Humidification Load Gal/Day 0 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 486 21 Total Load Sum lines 13 through 19 10874 5686 1075 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 3...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Right-J8® Form J1 Date:1st Floor By:Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com 1 Name of Room 1st Floor Room2 2 Running Feet of Exposed Wall 136.0 ft 136.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²1221.0ft 8.0 ft²1221.0ft 4 Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²1072.0 1.0 x 1072.0 ft ft²1072.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²1072.0°0 ft²1072.0° Type ofExposure Const.,NumberType ofExposure Const.,Number PanelFaces HTMPanelFacesHTM Area orLength BtuhArea orLength Btuh Area orLength BtuhArea orLength Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12E-0sw12E-0sw nn 4.524.52 1.151.15 288 967 247 288 967 247.GlazGlaz 1D-c2ovd1D-c2ovd nn 37.8537.85 19.6519.65 42 1590 825 42 1590 825.GlazGlaz 2 glazing, clr outr, n2 glazing, clr outr, n 17.2617.26 8.868.86 32 548 281 32 548 281.WallWall 12E-0sw12E-0sw ee 4.524.52 1.151.15 102 461 118 102 461 11811GlazGlaz2 glazing, clr outr, e2 glazing, clr outr, e 0.000.00 0.000.00 0 0 0 0 0 0WallWall12E-0sw12E-0sw ss 4.524.52 1.151.15 288 1148 293 288 1148 293GlazGlaz2 glazing, clr outr, s2 glazing, clr outr, s 17.2617.26 14.9614.96 34 584 506 34 584 506WallWall12E-0sw12E-0sw ww 4.524.52 1.151.15 256 899 230 256 899 230 GlazGlaz 2 glazing, clr outr, w2 glazing, clr outr, w 17.2617.26 27.5527.55 36 619 988 36 619 988DoorDoor11D011D0ww25.9025.90 10.1610.16 21 544 213 21 544 213 WallWall 12A-0sw12A-0sw --15.9415.94 3.683.68 154 2119 490 154 2119 490DoorDoor11D011D0nn25.9025.90 10.1610.16 21 544 213 21 544 213CeilCeil16B-30ad16B-30ad --2.122.12 1.591.59 341 725 541 341 725 541FlorFlor19C-30bswp19C-30bswp --0.980.98 0.230.23 1072 1049 248 1072 1049 248FlorFlor20P-11w20P-11w --0.000.00 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.330.33 3418 3418EffectWARWAR12Sensible Load (Btuh)ACH 1.00 370 1.00 3700.150.15 Latent Load (Btuh)454 Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 2000 200013cDefault Adjustments d Custom Appliances 0 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 15215 8754 454 15215 8754 Duct EHLF & ESGF 0.1200.120 0.0740.074 1826 652 1826 65215LoadsELG816 816 Vent CfmVent Cfm16Ventilation Loads 3535 E CfmE Cfm 3535 0 0 0 17 Winter Humidification Load Gal/Day 00 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 1190 1190 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 17041 9405 1271 17041 9405 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Mar-29 13:56:47Right-Suite® Universal 2021 21.0.08 RSU28723 Page 4...Design\[21-010-0556 Wayne Feiden] Heat Load.rup Calc = MJ8 Front Door faces: W 21-010-0556Job:Right-J8® Form J1 Date:2nd Floor By:Dandelion Energy 333 North Bedford Road, Suite 220, Mount Kisco, NY 10549 Phone: 833-GEO-4ALL Email: design@dandelionenergy.com Web: www.dandelionenergy.com 1 Name of Room 2nd Floor Room4 2 Running Feet of Exposed Wall 122.0 ft 122.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²976.0ft 8.0 ft²976.0ft 4 Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²770.8 1.0 x 770.8 ft ft²770.85Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²770.8°0 ft²770.8° Type ofExposure Const.,NumberType ofExposure Const.,Number PanelFaces HTMPanelFacesHTM Area orLength BtuhArea orLength Btuh Area orLength BtuhArea orLength Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12E-0sw12E-0sw nn 4.524.52 1.151.15 276 1246 318 276 1246 318.GlazGlaz 1D-c2ovd1D-c2ovd nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz 2 glazing, clr outr, n2 glazing, clr outr, n 0.000.00 0.000.00 0 0 0 0 0 0.WallWall 12E-0sw12E-0sw ee 4.524.52 1.151.15 212 839 214 212 839 21411GlazGlaz2 glazing, clr outr, e2 glazing, clr outr, e 17.2617.26 27.5527.55 26 453 723 26 453 723WallWall12E-0sw12E-0sw ss 4.524.52 1.151.15 276 1094 279 276 1094 279GlazGlaz2 glazing, clr outr, s2 glazing, clr outr, s 17.2617.26 14.9614.96 34 583 505 34 583 505WallWall12E-0sw12E-0sw ww 4.524.52 1.151.15 212 857 219 212 857 219 GlazGlaz 2 glazing, clr outr, w2 glazing, clr outr, w 17.2617.26 27.5527.55 22 384 613 22 384 613DoorDoor11D011D0ww0.000.00 0.000.00 0 0 0 0 0 0 WallWall 12A-0sw12A-0sw --0.000.00 0.000.00 0 0 0 0 0 0DoorDoor11D011D0nn0.000.00 0.000.00 0 0 0 0 0 0CeilCeil16B-30ad16B-30ad --2.122.12 1.591.59 771 1638 1222 771 1638 1222FlorFlor19C-30bswp19C-30bswp --0.000.00 0.000.00 0 0 0 0 0 0FlorFlor20P-11w20P-11w --5.185.18 0.740.74 40 208 30 40 208 30 Infiltration Heating Load (Btuh)0.480.48 3572 3572EffectWARWAR12Sensible Load (Btuh)ACH 1.00 387 1.00 3870.220.22 Latent Load (Btuh)475 Internal a Occupants at 230 and 200 Btuh 3 690 600 3 690 600 b Scenario number 0 013cDefault Adjustments d Custom Appliances 0 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 10874 5686 1075 10874 5686 Duct EHLF & ESGF 00 00 0 0 0 015LoadsELG0 0 Vent CfmVent Cfm16Ventilation Loads 2525 E CfmE Cfm 2525 0 0 0 17 Winter Humidification Load Gal/Day 00 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 486 486 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 10874 5686 1075 10874 5686 Job #: 21-010-0556 Performed for: Wayne Feiden57 Olander Dr Northampton, MA 01060 Dandelion Energy 333 North Bedford Road, Suite 220Mount Kisco, NY 10549Phone: 833-GEO-4ALL www.dandelionenergy.com design@dandelionenergy.com Scale: 1 : 101 Page 1Right-Suite® Universal 2021 21.0.08 RSU287232022-Mar-29 13:56:56 ...0556 Wayne Feiden] Heat Load.rup N First Floor Room2 Garage Job #: 21-010-0556 Performed for: Wayne Feiden57 Olander Dr Northampton, MA 01060 Dandelion Energy 333 North Bedford Road, Suite 220Mount Kisco, NY 10549 Phone: 833-GEO-4ALL www.dandelionenergy.com design@dandelionenergy.com Scale: 1 : 101 Page 2Right-Suite® Universal 2021 21.0.08 RSU287232022-Mar-29 13:56:56 ...0556 Wayne Feiden] Heat Load.rup N Second Floor Room4