Loading...
23D-148 BP-2023-0340 111 HINCKLEY ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 23D-148-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2023-0340 PERMISSION IS HEREBY GRANTED TO: Project# 2023 SOLAR Contractor: License: Est. Cost: 32000 TRINITY SOLAR CSL10802$ Const.Class: Exp.Date: 04/22/2024 Use Group: Owner: ALISE WILL, Lot Size (sq.ft.) Zoning: URB Applicant: TRINITY SOLAR Applicant Address Phone: Insurance: 32 GROVE ST (508)577-3391 WC 13588108 PLYMPTON, MA 02367 ISSUED ON: 03/20/2023 TO PERFORM THE FOLLOWING WORK: INSTALL 20 PANEL 8.1 KW ROOF MOUNT SOLAR SYSTEM WITH STRUCTURAL MODIFICATIONS POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: 14 • if . )2 . 3-1•1 . Fees Paid: S75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner The Commonwealth of Massachusetts � ... ;j¢ Board of Building Regulations and Standar FOR l' Massachusetts State Building Code, 780 CMR9 J �`• /, MUNICIPALITY kti° USE Building Permit Application To Construct, Repair,Re0yla e Or D olish a Revised Mar 2011 One- or Two-Family Dwelling '":r,''4r;\,, This Section For Official Use Only t,; Buildin Permit Number: 340 Date Applied: l 0 5 / 3 Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 111 Hinckley Street,Northampton,MA 1.1a Is this an accepted street?yesJ[ no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Residential-Solar Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard i Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? _ Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Alise Will Northampton MA 01062 Name(Print) City,State,ZIP 111 Hinckley Street (818)209-8838 lisawill27(a hotmail.com No.and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other Specify:Solar Brief Description of Proposed Work': Install 8.1 kW DC solar on roof(20 panels) Structural upgrades as described in engineering letter. Will not exceed building footprint, but will add 6"to roof height. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $9,000 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $23,000 ❑Standard City/Town Application Fee j ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: . 5.Mechanical (Fire $ Suppression) Total All Fees: $ h Check No.t�LI' Check Amount: Cash Am unt: 6. Total Project Cost: $32,000 0 Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-108025 4/22/2024 Phil Smith License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 6 Torrey St No.and Street Type Description asthampton,MA 01027 ,„, U Unrestricted(Buildings up to 35,000 cu.ft.) E /ha to ZIP R Restricted 1&2 Family Dwelling Cin' �� M Masonry X RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-203-9088 x 1524 applications.westma@trinity-solar.com I Insulation Telephone Email address D Demolition I 5.2 Registered Home Improvement Contractor(HIC) 170355 10/11/2023 Trinity Solar Inc DBA Trinity Solar HIC Registration Number EXpiration Date HIC Company Name or HIC Registrant Name 20 Patterson Brook Road-Unit 10 applications.westma@trinity-solar.com No.and Street Email address West Wareham MA 02576 413-203-9088 x 1524 City/Town, State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes 181 No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Please See Attached to act on my behalf,in all matters relative to work authorized by this building permit application. Print Owner's Name(Electronic Signature) Date I SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name belo I hereby attest under the pains and penalties of perjury that all of the information containe ' i app ' on is true and to to the best of my knowledge and understanding. X 03/16/2023 Print Owner' or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program ca be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 1 3. "Total Project Square Footage"may be substituted for"Total Project Cost" • o NJ,Electrical Contractor business permit number34E601547400 NJ,HIC reg.#13VH01244300 SOLAR For other jurisdictions,please visit:http://www.trinity-solar.com/about-us/locations-and-licenses HOMEOWNERS AUTHORIZATION FORM Alise Will (print name) am the owner of the property located at address: 111 Hinckley Street Northampton,Massachusetts 01062 United States (print address) I hereby authorize Trinity Solar Inc. ("Trinity Solar") and its employees, agents, and subcontractors, including without limitation, , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System, Battery System, roofing or other Trinity Solar offerings located on my property, applying and obtaining permission and approval for interconnection with the electric utility company, and registration with any state and/or local incentive program(s). This authorization includes the transfer/re-administering, and/or cancellation of any existing permits on file for the purpose of updating/applying with an alternate subcontractor. Without limitation to the generality of the foregoing I specifically authorize Trinity Solar et al.to populate technical details,fill-in,edit, compile, attach drawings, plans, data sheets and other documentation to, date, submit, re-submit, revise,amend and modify application, submission and certification documents ("Approvals Paperwork"), including those for which signature pages are included herewith for my signature, in furtherance of the related transaction, and I am providing any signatures to Approvals Paperwork for purposes of the foregoing.Trinity Solar will provide copies of Approvals Paperwork when submitted. My authorizations memorialized herein shall remain in full force and effect until revoked. I acknowledge that these authorizations are not required to proceed with the transaction and are not a condition of the related agreement included herewith but are being given for my own convenience and benefit in order to expedite the approvals processes. Electric Utility Company: National Grid Electric Utility Account No.: 5073407016 Name on Electric Utility Account: Alise Will Customer Signature Alise Will Print Name February 2, 2023 Date Corporate Headquarters 1-877-SUN-SAVES 2211 Allenwood Road Ph: 732-780-3779 Wall, New Jersey 07719 Fax: 732-780-6671 www.trinity-solar.com FOR INFORMATION ABOUT CONTRACTORS AND THE CONTRACTORS' REGISTRATION ACT, CONTACT THE NEW JERSEY DEPARTMENT OF LAW AND PUBLIC SAFETY, DIVISION OF CONSUMERS AFFAIRS AT 1-888-656-6225. • SOLAR Northampton, MA March 14, 2023 212 Main St. Northampton, MA 01060 RE: WILL,ALISE Trinity Solar No. 111 Hinckley Street 2023-01-824747 Northampton, MA 01062 To the Building Official: The following information constitutes a summary of the relevant design criteria and recommendations for the support of a new photovoltaic [PV]system on the existing roof framing components at the above-referenced location. Criteria is as follows: 1. Existing roof framing: Conventional roof framing at Roof R1 and R3 is 2x4 at 16 o.c.; existing rafter span= 11'0"; (horizontal projection) 2. Roof Loading: • 3.0psf dead load (pounds per square foot-PV panels, mounting rails&hardware) • 5.1 psf-existing roof loads(1.1 psf-2x4 framing, 1.5psf roof sheathing, 2.5psf shingles) • Ground Snow Load -40psf • Wind criteria-Exposure Category B, 117 mph wind 3. Existing Roof modification- Existing roof rafters to be"sistered"with new 2x6 rafters extending the full length of the existing rafters and terminated before the existing rafter support connection. Non-full-length rafter sisters must"overlap"its accompanied sister a minimum of 24"with nailing from each side in the overlap. Sisters to use (2)10d nails, one top and one bottom (staggered)at 8"o.c the length of the sisters(4" in overlap), and located 1"from edge of the 2x4s. Provided two vertical row of(3) 10d nails at 3"oc. at each end of the 2x6 sisters. If sistering is not feasible, provide 2x4(@16"o.c.)"knee wall"reinforcing to limit the maximum span of the existing rafter to 7'-2". Locate bottom of"knee wall"within one foot of existing bearing wall below. This installation design is in general conformance with the manufacturers' specifications and complies with all applicable laws, codes, and ordinances—specifically the International Building Code (2015 edition)and the International Residential Code(2015 edition), including all Massachusetts regulations and amendments. The spacing and fastening of the mounting brackets is a maximum of 48"o.c. between mounting brackets(staggered)and is secured using 5/16"diameter corrosive-resistant steel lag bolts.A minimum of 21/2"of penetration (embedment) per lag bolt is required,which will resist all stated loads above—including wind shear. Per NDS Section 12.1.4, clearance holes-equal to the diameter of the shank-need to be bored into a primary framing member for the full-length of the threaded portion of the bolt to avoid splitting of the framing member. Regards, Thor Bojcun, PE Structural Engineer-Trinity Solar OF ., ct f CIVIL .�8F 10, ti j, • MA License No.56667 Trinity Solar 14 Open Square Way,Suite 410 I Holyoke, MA I(413)203-9088