12-015 (5) BP-2023-0285
49 COUNTRY WAY COMMONWEALTH OF MASSACHUSETTS
Map:Block:Lot:
12-015-001 CITY OF NORTHAMPTON
Permit: Alts Renovations
Repair
PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
BUILDING PERMIT
Permit# BP-2023-0285 PERMISSION IS HEREBY GRANTD TO:
Project# CHIMNEY RE-LINE 2023 Contractor: License:
Est. Cost: 2645 CORY MCGILL 107658
Const.Class: Exp.Date: 05/25/2023
Use Group: Owner: PATRICIA WINGFIELD EDWARD &J
Lot Size (sq.ft.)
Zoning: WSP Applicant: CORY MCGILL DBA DONE RIGHT C IMNEY
Applicant Address Phone: Insurance:
PO BOX 1054 (413)340-1399 WCV 01525601
WILLIAMSBURG, MA 01096
ISSUED ON: 03/09/2023
TO PERFORM THE FOLLOWING WORK:
CHIMNEY RE-LINE
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter: Footings:
Rough: Rough: House # Foundation:
Final: Final: Final: Rough Frame:
Gas: Fire Department Driveway Final: Fireplace/Chimney:
Rough: Oil: Insulation:
Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature: 31'1 •
Fees Paid: $65.00
212 Main Street,Phone(413)587-1240,Fax:(413)587-1272
Office of the Building Commissioner
The Commonwealth of Massachusetts
W Board of Building Regulations and Stand. ; . FOR
Massachusetts State Building Code, 780 C ' , MUNICIPALITY
USE
Building Permit Application To Construct,Repair,RenoKate Or D-( i sh a Revised Mar 2011
One-or Two-Family Dwelling ,` \_
This Section For Official Use Only ''',
Building Permit Number: ^ 2-3.. 2 g.S Date Ap lied:
l -0,�72-7, ./ -R-ZoZ3
Building Official(Print Name) Signature Date
SECTION 1: SITE INFORMATION
1.1 Property Address: 1.2 Assessors Map&Parcel Numbers
49 Country Way, Northampton, MA 01062
1.1a Is this an accepted street?yes no Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions:
Zoning District Proposed Use Lot Area(sq ft) Frontage(ft)
1.5 Building Setbacks(ft)
Front Yard Side Yards Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0
Check if yes❑
SECTION 2: PROPERTY OWNERSHIP'
2.1 Owner'of Record:
Ed Wingfield Northampton, MA 01062
Name(Print) City,State,ZIP
49 Country Way (413)575-4825 wingfield06@gmail.com
No.and Street Telephone Email Address
SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply)
New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0
Demolition 0 Accessory Bldg. 0 Number of Units Other M'Specify:Chimney re-line
Brief Description of Proposed Work2:Level 2 Inspection completed 11/18/2023.To prepare existing masonry chimney for
installation of(1)5"stainless steel tee liner kit.To vent existing oil burner to stainless steel tee liner kit.
SECTION 4:ESTIMATED CONSTRUCTION COSTS
Item Estimated Costs: Official Use Only
(Labor and Materials)
1.Building $ 2,645.55 1. Building Permit Fee:$ Indicate how fee is determined:
2. Electrical $ ❑Standard City/Town Application Fee
❑Total Project Cost;(Item 6)x multiplier x
3. Plumbing $ 2. Other Fees: $
4.Mechanical (HVAC) $ List:
-
5. Mechanical (Fire $ /
Suppression) Total All Fees: ,1 � �n(�
Check No.7O'Check Amount: V' Cash Amount:
6.Total Project Cost: $ 2,645.55 0 Paid in Full 0 Outstanding Balance Due:
SECTION 5: CONSTRUCTION SERVICES
5.1 Construction Supervisor License(CSL)
CS-107568 05/25/2023
Cory McGill License Number Expiration Date
Name of CSL Holder
List CSL Type(see below) U
P.O. Box 1054
No.and Street Type Description
Williamsburg, MA 01096 U Unrestricted(Buildings up to 35,000 cu.ft.)
R Restricted 18t2 Family Dwelling
City/Town,State,ZIP M Masonry
RC Roofing Covering
WS Window and Siding
SF Solid Fuel Burning Appliances
(413)340-1399 ContactDoneRight@gmail.com I Insulation
Telephone Email address D Demolition
5.2 Registered Home Improvement Contractor(HIC)
#178722 08/27/2024
Cory McGill HIC Registration Number Expiration Date
HIC Company Name or HIC Registrant Name
P.O. Box 1054 ContactDoneRight@gmail.com
No.and Street Email address
Williamsburg. MA 01096 (413)340-1399
City/Town,State,ZIP Telephone
SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes ® No O
SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I,as Owner of the subject property,hereby authorize Cory McGill
to act on my behalf, in all matters relative to work authorized by this building permit application.
Ed Wingfield."111111t X6 J0111OOIE5 Mar 6,2023
Print Owner's Name(Electronic Signature) Date
SECTION 7b:OWNER1 OR AUTHORIZED AGENT DECLARATION
By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
Cory McGill o314I ao��
Print Owner's or Autho Agent e(Electronic Signature) Date
NOTES:
1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration
program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at
www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps
2. When substantial work is planned,provide the information below:
Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch)
Gross living area(sq.ft.) Habitable room count
Number of fireplaces Number of bedrooms
Number of bathrooms Number of half/baths
Type of heating system Number of decks/porches
Type of cooling system Enclosed Open
3. "Total Project Square Footage"may be substituted for"Total Project Cost"
The Commonwealth of Massachusetts
1 „ Department of Industrial Accidents
=;�1= l Office of Investigations
C = _ 1 Congress Street, Suite 100
- —.ultztil- Boston, MA 02114-2017
www.mass.gov/dia
Workers' Compensation Insurance Affidavit: General Businesses
Applicant Information Please Print Legibly
Business/Organization Name: Done Right Chimney
Address:P.O. Box 1054,45 Main Street, Unit B
City/State/Zip:Williamsburg, MA 01096 Phone#: (413)340-1399
Are you an employer?Check the appropriate box: Business Type(required):
1.❑I• I am a employer with 4 employees (full and/ 5. ❑■ Retail
or part-time).* 6. E Restaurant/Bar/Eating Establishment
2.❑ I am a sole proprietor or partnership and have no 7. ❑ Office and/or Sales(incl.real estate, auto,etc.)
employees working for me in any capacity.
[No workers' comp. insurance required] 8. ❑Non-profit
3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment
their right of exemption per c. 152, §1(4),and we have 10.0 Manufacturing
no employees. [No workers' comp. insurance required]** 11.0 Health Care
4.❑ We are a non-profit organization, staffed by volunteers,
with no employees. [No workers' comp. insurance req.] 12.0 Other Services:Chimney&Hearth
*Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information.
**if the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an
organization should check box tt 1.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information.
Insurance Company Name:Atlantic Charter Insurance Company
Insurer's Address:45 Main Street,Unit B
City/State/Zip: Williamsburg, MA 01096
Policy#or Self-ins. Lic.# WCV 01525601 Expiration Date:06/28/2023
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certify,under the pains and penalties of perjury that the information provided above is true and correct.
SOj/Signature: `-, ( tL Date: Q3)Q640/ t23
Phone#: (413)340-1399
Official use only. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License #
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office
6.Other
Contact Person: Phone#:
www mass gov/dia
City of Northampton 212 Main Street, Northampton, MA 01060
Solid Waste Disposal Affidavit
In accordance of the provisions of MGL c 40, S54, I acknowledge that as
a condition of the building permit all debris resulting from the construction
activity governed by this Building Permit shall be disposed of in a properly
licensed solid waste disposal facility, as defined by MGL c 111 , S 150A.
Address of the work: 49 Country Way, Northampton, MA 01062
The debris will be transported by: Done Right Chimney
The debris will be received by: Valley Recycling, 234 Easthampton Road, Northampton MA
Building permit number:
Name of Permit Applicant Cory McGill
6)10GAP7) /0/(,f)‘'
Date Signature of Permit Applicant
INSTALLATION INSTRUCTIONS Ph ne:888-900-8106
FOR BEST-Flex Models "L", "H", "S", & "E" ax:888 392 4432
STAINLESS STEEL CHIMNEY LINERS Web:www.NewEnglandC imneySupply.com
34 Commerce Street, illiston VT' 05495
sim MI6
BEST-Flex Models
,,u, ,,H,) ccs» cc » eesr
7 , , OFLEX
New England Supply PRODUCTS
STAINLESS STEEL CHIMNEY LINERS
BEST-Flex Models"L","H","S",&"E"Stainless Steel Chimney Liners are manufactured by New England Supply Inc.Located in Williston,VT.
The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys.BEST-Flex liners are used to vent the gases and by-products
produced by appliances that burn oil,gas,or solid fuels.
All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best
operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance.
The installer must contact the local building and fire code officials for a variety of reasons:
• The installation may require special inspection requirements.
• Building permits may be required before installation.
• Compliance with local building codes.(Authorities with local jurisdiction such as Inspectors,Municiple Building Departments,Fire Departments,and
Fire Bureau's have precedence over national codes).
For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials not specified may result
in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not
followed
BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories.
• In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys.
• In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys.
PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS
• The BEST-Flex Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new construction.
Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed
by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation.BEST-Flex can be used to vent wood,wood pellet,coal,non-
condensing gas and oil,making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available in 3"'to 12"diameters
(13"above is not listed)to cover a wide range of requirements found in the field today.
• The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel,7-ply interlocked and crimped to produce
a gas and water tight lining system of superior strength and durability.BEST-Flex can be curved to go around offsets in chimneys and can be factory
ovalized to custom sizes to fit most any installation requirement.Unless specified by the manufacturer,the liner is not to be field ovalized. The
corrugated construction allows for expansion&contraction during the heat-up&cool-down periods,which removes any stresses on the system.
• BEST-Flex can be insulated with either a vermiculite based poured insulation or with a foil-faced ceramic wool blanket to meet UL 1777&ULC S635
standards for chimney exteriors with zero dearance to combustibles.
• BEST-Flex Stainless Steel Chimney Liner comes with a Life Time Warranty for all fuels,with appliance efficiencies at 83 percent or lower.
MATERIALS REQUIRED FOR BEST-Flex STAINLESS STEEL LINER INSTALLATION:
Liner Model-"L", "H", "S", &"E"
TT/TB-Two piece or one piece tee i g
i
TEC-Tee Cap
EA/EF-15°-90°elbow
C/CC-Coupler
Screws/Rivets
OPTION A ,, 0 OPTION B
TP-Top Plate '`'' TPCC-Liner Cap
TC-Top Clamp • IC)! OR TPC-Top Plate OR
SC-Storm Collar
CL-Liner Cap(square/round)
INSULATION MATERIALS REQUIRED(if applicable)
Part# Description
LI2 Liner Insulation 1/2"Foil Faced Ceramic Wool Blanket
LM Liner Mesh Protective Wire Mesh Sleeve
FT(2", 3") Aluminum Foil Tape '
LMC(large/small) Mesh Clamp 'r !t
BMIX BEST Mix
-ti•AN,
Phone:888-900-8106
L_N_i�T� Fax:888-392-4432
Web:www.NewEnglandChimneySupply.com
New England Supply 34 Commerce Street,Williston VT 05495
1.)CHIMNEY PREPARATION&INITIAL INSPECTION
Before any liner can be installed the existing chimney must meet proper construction and code requirements:
• The chimney must be between 10-ft high(min)and 100-ft(max)in height.
• The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit.
• The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius.
• If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any
combustible material.If the chimney is constructed on the outside of the structure,1-in of unobstructed air space must be maintained between the
chimney mass and all other combustible materials.
• When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used.
• The installer must verify the above with all local&national codes as required.
• If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material.
• Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance.
• The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the
appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence.
• The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full
inspection must be done to determine if the chimney is structurally sound.If the existing system is found not to be in compliance with applicable
building code and/or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring
the chimney or vent into compliance with the applicable code and/or manufacturer's instructions.
Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any
applications that require a vent or chimney of a higher temperature handling capability,an alternative fuel,or any other more sever service than the original
chimney or vent in which it is installed. CHIMNEY CEN2lECtO0s AND VENT CONNECTORS
2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER
N°""'u"cranny deem. System A.Minimum 3.5 in.(90 non)Slob brick masonry wall framed into
• Any heating appliance connected to the lining system must not "tape and conwsand _e.I comestible coal with mHmm of 12 n.(305 mm)bnuc federation
have a flue outlet size larger than the liner area at its smallest ) — 'm'ls''''° :+: 21,77.` `° born°lyNeer'ecnmwsbaa..Rredar"ner(AST*Ic315.
r. we amid, Standard Specification ter Clay Flue Linea and Chhroney Pala Kronen,*
point,unless a qualified person has sized the liner to suit the r 4.174 IN minimum%0n(16nan)walwdubss,Malrunfeanouers na
c brick oat to but not beyond,the inner surface ol chimney flue
appliance , a= MN ante end shell he linty cemented toMace
• For sizing a liner used for gas and oil burning appliances refer nnin':mi Clearance ISO(305mm1
so
to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the m„imum12„,� 0) . "
Feactsy
appliance manufacturer's instructions.Liners that are incorrectly 6Combustibles
°"4 `
4Unooy01
ei" toNFPA21h
sized for the appliance can lead to poor draft,excessive
condensation,and creosote build-up inside the lining system. Minimum clammy clearance from System s.Solid-insulated,listed le y itdekn.ylengthofthesame
mesurry to sheet weal.upporla end 000100 Swiftdiameter as the chimneyconnector and having 1 in.Please call New England Supply Inc.should you have any t°""ii°"'°2 in.(51 mei I ; ,n,,,,) (25 rem)or more of insulation with a minimum 9 in.(229 rem)
questions about sizinga liner. fedpryb is "°"""• ale spew between the outer wall of the chimney length and
mmnmhgN acl0ry r FI1 G*'•l combuslles.
• For sizinga liner used for solid fuel burningappliances the cross I
�I 0 A°d0 The inner end of the chimney length slog be bush with the
PP Penny length, amide dthe masonry chimney flue and shall be sealed to the flue
section area of the liner shall not be less than the cross section munwmra,da and to the°"cknNt0mypenetm""'wihn°"""a` le
' o.rue _ I Us.,n.nney refractory cement.Supports shay be securely fastened to wall
area of the appliance outlet collar.Unless specified bythe z" m"a pare a mutates on all sides.
PP P III q'nl mm,,,xn. 0"f°m•2 d1
Es ""'rt0i Fasteners between supports and the chimney length shall notappliance the cross section area of the flue shall not be more than ace - penetrate the chimney liner.
three(3)times the cross section area of the appliance outlet collar. "m;7ap,,2;, „e°'0tl0ryn* :9n1229mm)
m•s gm
Solid fuel burning fireplace liners should be a minimum of one- Seeel elan warrant
twelfth(1/12)the square inches compared to the square inches
of the fireplace opening.This one-twelfth(1/12)number can 00nsm chancey clearance to anent�_ System C.shealsteddh:nthy connector,minimm24 gauge[0.024in.
steel supports end combustibles, �a (0.61mm))I thickness,with a wenloal.d thimble,minimum
vary based on height of the chimney along with other calculating 2 In.t51e n) ;- Two as meows 24 gauge[0.024in(0.91mingintMdahes,twine Iwo Iin.
• rail e0001 m.125 met (25 rem)an charnels,separated from wnkbMMe5 by a ednem.
factors.Call New England Supply Inc.if you have any questions. -. s {�l�i J Chi of61n(152 non)of glees fiber insulation.Opening shell be covered,
and 4fl(0imported with a sheet steel support,mmmum 24 gauge
N\•// NM—00n1''' [0.024In(0.61mm)1inmi yla.s.
3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT INTO ' _ S'asp°ne"'a"t"'""refy"e`enedtowal"elaw°onat"d"
^dnimhm 6 hn. and shaft be sized to fit and hold chimney section.Fasteners used
THE CHIMNEY r» wmmeaaa e,"'e I1.N ;'52mm,v.na le Were chimneysectionshalnotpenetratechimneyflueMet
�. hb.,o001.90,
• The BEST-Flex Stainless Steel Chimney Liner can be installed
Minn*.
h nmme ktawmw chimney -' ceemw:em.(,52mm>
inside the existing flue tile or the flue tile can be removed.It w..a ucaon of wananicledtoN1M211 sra.l.w.„ ov0 e
is critical that the correct size liner will actually fit into the flue.
Chimney construction and flue offsets may change the physical Mur.m.ewwwyc.waretoawa slag aaao,hsend System D.SoNd•toetalad,listed t.d .wnmklahey length wlmamamide
coe000Nm z In(51 mm) diameter 2 in.(51 mm)leader than the chimney Manacle and hawig
size of the interior of the chimney.It is best to test the smallest Ito.(25 rem)orrasa d emulation.serving as e peae4mmugh fore single
A .r Shea,steel it r—MNos,0d.a,mce 2 in.(5r rem) wall sheet steal chimneycomedor d minimum 24 gauge[0.024 it
point of the chimney interior before trying to install the chimney i •°�°n° s t. 0.61mm)[aw aaee,wn emaemum2 n.(51 mm)ah apace between the
liner.Lower a short piece of the correct size liner down the 'r; 's I. e'.125" ,5000. outer""'°'dm""ieLOnandcombustibles.
m Nwmney lenphMNnbnum lengtlh of chimney section ow be 121n.1309 rem).Chimney
chimneyto see if it will fit through,or a linerguide cone.If the sedgy°oncentricwthandpaced'".(zsmm)awyfromconned«y
g uw e ® means d sheet steel led,arl papas on both ease chimney aspeon
chimney liner needs to be insulated extra space around the liner Mj°° 1°f i w•'hingsh•lbewmmaaneddmneysewehsuppamedonmmsideswth
N i�" ",.Chaney cammchor sheet steel supporta n1 minimum 24 gauge[0.024 in.(0.61 mm)l t in/me a
is required.If a round liner configuration will not fit the liner can be �._. tic w,,�a Spponsshall be securely ast w wail sur,aseson all smae
Arspae a:.(51 tem) S and shall be fixed to lit and hold chimney aeebon Fasteners used
formed into an oval shape to fit at the factory. However an oval M„esy Shier ewe to secure cmto.ys.ctonshell not penetrate chhneyflue liner.
liner will change the cross section area and a larger liner may be PM2t' Clearance:2 n.(51 mm)
needed.Please call New England Supply Inc.with any questions.
Note;All clearances and Ithdmesses are minimums;lager clearances and thicknesses are permitted.
4.)INSTALLING THE BEST-FLEX STAINLESS STEEL CHIMNEY LINER
• Thimbles must be in the proper location to maintain the required clearance to combustibles from the connector pipe to the appliance. The liner
length is determined by measuring from the lowest thimble(if more than one)to the top of the chimney.Add approximately Six(6)inches to attach
the crown and top hardware.Cut the liner to the desired length.
• If a liner is not long enough a coupler may be used to join two pieces of liner.Attach the Coupler to the liner with the affixed band,or stainless steel
screws(Male end down when applicable).
• Attach the Tee Body to the liner with the affixed band,or stainless steel screws.If the liner needs to be insulated with a ceramic wool blanket,install
the blanket at this point. Attach the Tee Cap to the Tee Body at this point.
• Expand the draw band on the Tee Snout completely,slide the Tee Snout into the thimble with the draw band centered in the flue.Lower the liner