Savage - Stamped Plan Set1.1.1 PROJECT NOTES: 1.1.2 THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.1.3 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.1.4 ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.1.5 MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.1.6 ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.1.7 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.2.1 SCOPE OF WORK: 1.2.2 PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.3.1 WORK INCLUDES: 1.3.2 PV ROOF ATTACHMENTS - IRONRIDGE FLASHFOOT2 1.3.3 PV RACKING SYSTEM INSTALLATION - IRONRIDGE XR-100 1.3.4 PV MODULE AND INVERTER INSTALLATION - JA SOLAR JAM54S31-395/MR / SOLAR EDGE SE10000H-US (240V) WITH PRISM TECHNOLOGY / BACKUP INTERFACE BI-EUSGN-01/ SOLAR EDGE ENERGY BANK 10KWH 1.3.5 PV EQUIPMENT GROUNDING 1.3.6 PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.3.7 PV LOAD CENTERS (IF INCLUDED) 1.3.8 PV METERING/MONITORING (IF INCLUDED) 1.3.9 PV DISCONNECTS 1.3.10 PV FINAL COMMISSIONING 1.3.11 (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.3.12 SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE GENERAL NOTES N2017C SCOPE OF WORK SYSTEM SIZE: STC: 35 x 395W = 13.825kW PTC: 35 x 368.7W = 12.905kW (35) JA SOLAR JAM54S31-395/MR (1) SOLAR EDGE SE10000H-US ENERGY HUB INVERTER WITH PRISM TECHNOLOGY (240V) (2) SOLAREDGE ENERGYBANK 10KWH (1) BACKUP INTERFACE BI-EUSGN-01 ATTACHMENT TYPE: IRONRIDGE FLASHFOOT2 MSP UPGRADE: NO OWNER NAME: FRANCIS SAVAGE PROJECT MANAGER NAME: ERIC WILSON PHONE: CONTRACTOR NAME: INSIGHT SOLAR PHONE: 4133387555 AUTHORITIES HAVING JURISDICTION BUILDING: NORTHAMPTON CITY ZONING: NORTHAMPTON CITY UTILITY: DESIGN SPECIFICATIONS OCCUPANCY: II CONSTRUCTION: SINGLE-FAMILY ZONING: RESIDENTIAL GROUND SNOW LOAD: 40 PSF WIND EXPOSURE: B WIND SPEED: 117 MPH APPLICABLE CODES & STANDARDS BUILDING: MASSACHUSETTS BUILDING CODE, 9TH EDITION, ASAMENDED (780 CMR) MASSACHUSETTS RESIDENTIONAL BUILDING CODE, 9TH EDITION, AS AMENDED (780 CMR) ELECTRICAL: NEC 2020 FIRE: MASSACHUSETTS COMPREHENSIVE FIRE SAFETY CODE (527 CMR 1.00) PROJECT INFORMATION NEW PV SYSTEM: 13.825 kWp SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 ASSESSOR'S #: 31B-171-001 B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 T-001.00 COVER PAGE (SHEET 1) 01 AERIAL PHOTO NOT TO SCALE N EW S 02 PLAT MAP NOT TO SCALE SHEET LIST TABLE SHEET NUMBER SHEET TITLE T-001 COVER PAGE G-001 NOTES A-101 SITE PLAN A-102 ELECTRICAL PLAN A-103 SOLAR ATTACHMENT PLAN E-601 LINE DIAGRAM E-602 DESIGN TABLES E-603 PLACARDS S-501 ASSEMBLY DETAILS R-001 RESOURCE DOCUMENT R-002 RESOURCE DOCUMENT R-003 RESOURCE DOCUMENT R-004 RESOURCE DOCUMENT R-005 RESOURCE DOCUMENT R-006 RESOURCE DOCUMENT R-007 RESOURCE DOCUMENT HENSHAW AVE11-22-2022 2.1.1 SITE NOTES: 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES. 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.1.6 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 2.2.1 EQUIPMENT LOCATIONS 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C). 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.3.1 STRUCTURAL NOTES: 2.3.2 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 2.4.1 GROUNDING NOTES: 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.4.3 PV SYSTEMS REQUIRE AN EQUIPMENT GROUNDING CONDUCTOR. ALL METAL ELECTRICAL EQUIPMENT AND STRUCTURAL COMPONENTS BONDED TO GROUND, IN ACCORDANCE WITH 250.134 OR 250.136(A). ONLY THE DC CONDUCTORS ARE UNGROUNDED. 2.4.4 PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 2.4.5 METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURE CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 2.4.8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 2.4.10 DC PV ARRAYS SHALL BE PROVIDED WITH DC GROUND-FAULT PROTECTION MEETING THE REQUIREMENTS OF 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS 2.5.1 INTERCONNECTION NOTES: 2.5.2 LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12 (B)] 2.5.3 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(B)(2)(3)]. 2.5.4 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)]. 2.5.5 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C). 2.5.6 FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (B)(2)(1) 2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.5.8 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)]. 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH. 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED, ACCORDING TO NEC 690.13. 2.6.5 ISOLATING DEVICES OR EQUIPMENT DISCONNECTING MEANS SHALL BE INSTALLED IN CIRCUITS CONNECTED TO EQUIPMENT AT A LOCATION WITHIN THE EQUIPMENT, OR WITHIN SIGHT AND WITHIN 10 FT. OF THE EQUIPMENT. AN EQUIPMENT DISCONNECTING MEANS SHALL BE PERMITTED TO BE REMOTE FROM THE EQUIPMENT WHERE THE EQUIPMENT DISCONNECTING MEANS CAN BE REMOTELY OPERATED FROM WITHIN 10 FT. OF THE EQUIPMENT, ACCORDING TO NEC 690.15 (A). 2.6.6 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D) 2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 2.6.8 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED, THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION, ACCORDING TO NEC 240.21. (SEE EXCEPTION IN NEC 690.9) 2.6.9 IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. 2.7.1 WIRING & CONDUIT NOTES: 2.7.2 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 2.7.4 EXPOSED PV SOURCE CIRCUITS AND OUTPUT CIRCUITS SHALL USE WIRE LISTED AND IDENTIFIED AS PHOTOVOLTAIC (PV) WIRE [690.31 (C)]. PV MODULES WIRE LEADS SHALL BE LISTED FOR USE ON PV ARRAYS, ACCORDING TO NEC 690.31 (A). 2.7.5 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE [NEC 200.6 (A)(6)]. 2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. 2.7.7 ACCORDING TO NEC 200.7, UNGROUNDED SYSTEMS DC CONDUCTORS COLORED OR MARKED AS FOLLOWS: DC POSITIVE- RED, OR OTHER COLOR EXCLUDING WHITE, GRAY AND GREEN DC NEGATIVE- BLACK, OR OTHER COLOR EXCLUDING WHITE, GRAY AND GREEN 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE*, OR OTHER CONVENTION NEUTRAL- WHITE OR GRAY * IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. N2017C N2017C B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 G-001.00 NOTES (SHEET 2) 11-22-2022 GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE PROPERTY LINE N EW S 01/16" = 1'-0" SITE PLAN01 8' 16' B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 A-101.00 SITE PLAN (SHEET 3) AREA OF WORK ENTRANCE HENSHAW AVE UTILITY METER AC DISCONNECT BACKUP INTERFACE DC RAPID SHUTDOWN SHUNT TRIP 32'-1" 40'-11" 7'-9" 21'-3" 11-22-2022 MODULE: JA SOLAR JAM54S31-395/MR 395 WATTS 44.65'' 67.8'' GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 01/8" = 1' ELECTRICAL PLAN014' 8'A-102.00 ELECTRICAL PLAN (SHEET 4) MODULE STRINGING MODULE STRINGING A B INTERIOR PV EQUIPMENT (E) (1) UTILITY METER EXTERIOR PV EQUIPMENT (N) (1) AC DISCONNECT (N) (1) INVERTER (E) (1) MAIN ELECTRICAL PANEL (N) (2) BATTERIES (N) (1) BACKUP INTERFACE MODULE STRINGINGC (N) (1) DC RAPID SHUTDOWN SHUNT TRIP A ARRAY 1 - 1.975 kW [x5] (N) MODULES TILT: 42 DEGREES ROOF PITCH: 11:12 AZIMUTH: 190 DEGREES N EW S (N) (1) JUNCTION BOX A A A A A AAA B B B B BB B B B B B B C C C C C C C C C C C C CC ARRAY 2 - 2.370 kW [x6] (N) MODULES TILT: 42 DEGREES ROOF PITCH: 11:12 AZIMUTH: 190 DEGREES ARRAY 3 - 1.580 kW [x4] (N) MODULES TILT: 42 DEGREES ROOF PITCH: 11:12 AZIMUTH: 280 DEGREES ARRAY 4 - 2.370 kW [x6] (N) MODULES TILT: 5 DEGREES ROOF PITCH: 1:12 AZIMUTH: 0 DEGREES ARRAY 5 - 5.530 kW [x14] (N) MODULES TILT: 5 DEGREES ROOF PITCH: 1:12 AZIMUTH: 0 DEGREES 11-22-2022 GENERAL NOTES 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE ROOF RAFTERS MODULE: JA SOLAR JAM54S31-395/MR 395 WATTS 44.65'' 67.8'' B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 01/8" = 1' SOLAR ATTACHMENT PLAN014' 8'A-103.00 SOLAR ATTACHMENT PLAN (SHEET 5) ROOF MATERIAL IS ASPHALT SHINGLE N EW S FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE (SEE SHEET S-501 FOR MOUNTING DETAILS) 11'-2"14'-11" 11'-2" 11'-2" 26'-1" 11-22-2022 1. PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN DISCONNECT PER NEC 690.12 2. SYSTEM COMPLIANT WITH NEC 690.13 6 GG L1 L2 N N G (E) MAIN 200A TO (E) LOADS (E) MAIN ELECTRICAL PANEL 240/120 V 1Ø, 3W MAIN BUSS: 200A SOLAR EDGE SE10000H-US ENERGY HUB INVERTER WITH PRISM TECHNOLOGY (240V) NOMINAL OUTPUT POWER = 10000W (N) (35) JA SOLAR JAM54S31-395/MR 395W (N) (35) SOLAR EDGE P401 POWER OPTIMIZER BACKUP INTERFACE BI-EUSGN-01-+I SOLAREDGE ENERGYBANK 10KWH 3 4 G AC DISCONNECT 60A 7 -+I SOLAREDGE ENERGYBANK 10KWH 5 L2 N L1 (E) UTILITY METER L1 L2 N G GNL2L1 L1 L2 N G NL2L1 GNL2L1G EXT RSD ON OFF CB1 200A/2P60A (N) DC RAPID SHUTDOWN SHUNT TRIP L2 N L1 TO UTILITY GRID (OH) CB2 MODULE STRINGINGA MODULE STRINGINGB MODULE STRINGINGC (E) GROUNDING ELECTRODE GROUND ROD G 2 IN BRANCH A 9 IN BRANCH B 12 1 IN BRANCH C 14 (N) JUNCTION BOX CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%)BASE AMP.DERATED AMP.TERM. TEMP. RATING AMP. @ TERMINAL 1 3 10 AWG PV WIRE, COPPER FREE AIR 2 N/A 6 AWG BARE, COPPER 0.96 (32.7 °C)1 15A 18.75A 55A 52.8A 75°C 50A 21 10 AWG THWN-2, COPPER 0.75'' DIA EMT 6 N/A 6 AWG THWN-2, COPPER 0.96 (32.7 °C)0.8 15A 18.75A 40A 30.72A 75°C 35A 3 1 6 AWG THWN-2, COPPER 0.75'' DIA EMT 3 N/A 6 AWG THWN-2, COPPER 0.96 (32.7 °C)1 42A 52.5A 75A 72A 75°C 65A 41 6 AWG THWN-2, COPPER 0.75'' DIA EMT 3 60A 6 AWG THWN-2, COPPER 0.96 (32.7 °C)1 42A 52.5A 75A 72A 75°C 65A 5 1 3/O AWG THWN-2, COPPER 0.75'' DIA EMT 3 200A -0.96 (32.7 °C)1-200A 225A 216A 75°C 200A 61 3/O AWG THWN-2, COPPER 1'' DIA EMT 3 200A 6 AWG THWN-2, COPPER 0.96 (32.7 °C)1 - 200A 225A 216A 75°C 200A 72 10 AWG THWN-2, COPPER 0.75'' DIA EMT 4 N/A - 0.96 (32.7 °C)1 20A 25A 40A 38.4A 75°C 35A E-601.00 LINE DIAGRAM (SHEET 6) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 11-22-2022 BILL OF MATERIALS CATEGORY MAKE MODEL NUMBER REF QTY UNIT QTY/UNIT DESCRIPTION MODULE JA SOLAR JAM54S31-395/MR PM1-35 35 PIECES 1 JA SOLAR JAM54S31-395/MR 395W 108 HALF-CELLS, MONOCRYSTALLINE SILICON INVERTER SOLAR EDGE SE10000H-US (240V) ENERGY HUB INVERTER WITH PRISM TECHNOLOGY (240V)I1 1 PIECE 1 SOLAR EDGE SE10000H-US (240V) ENERGY HUB INVERTER WITH PRISM TECHNOLOGY (240V) 10000W INVERTER MODULE OPTIMIZER SOLAR EDGE P401 PO1-35 35 PIECES 1 SOLAR EDGE P401 OPTIMIZER (REQUIRED PART OF INVERTER'S DISTRIBUTED DC ARCHITECTURE) DISCONNECT EATON DG222URB SW1 1 PIECE 1 EATON DG222URB, NON FUSED, 2-POLE, 60A, 240VAC OR EQUIVALENT BACKUP INTERFACE SOLAR EDGE BI-EUSGN-01 BI1 1 PIECE 1 SOLAR EDGE BACKUP INTERFACE BI-EUSGN-01, 200A MAX STORAGE BATTERY SOLAR EDGE ENERGY BANK 10KWH BB1-2 2 PIECES 1 STORAGE BATTERY SOLAR EDGE ENERGY BANK 10KWH WIRING GEN-10-AWG-PV-WIRE-CU WR1 270 FEET 1 10 AWG PV WIRE, COPPER (POSITIVE AND NEGATIVE) WIRING GEN-6-AWG-BARE-CU WR1 135 FEET 1 6 AWG BARE, COPPER (GROUND) WIRING GEN-10-AWG-THWN-2-CU-RD WR2, 7 60 FEET 1 10 AWG THWN-2, COPPER, RED (POSITIVE) WIRING GEN-10-AWG-THWN-2-CU-BLK WR2, 7 60 FEET 1 10 AWG THWN-2, COPPER, BLACK (NEGATIVE) WIRING GEN-6-AWG-THWN-2-CU-RD WR3-4 30 FEET 1 6 AWG THWN-2, COPPER, RED (LINE 1) WIRING GEN-6-AWG-THWN-2-CU-BLK WR3-4 30 FEET 1 6 AWG THWN-2, COPPER, BLACK (LINE 2) WIRING GEN-6-AWG-THWN-2-CU-WH WR3-4 30 FEET 1 6 AWG THWN-2, COPPER, WHITE (NEUTRAL) WIRING GEN-6-AWG-THWN-2-CU-GR WR2-4,6 40 FEET 1 6 AWG THWN-2, COPPER, GREEN (GROUND) WIRING GEN-3/0-AWG-THWN-2-CU-RD WR5-6 40 FEET 1 3/0 AWG THWN-2, COPPER, RED (LINE 1) WIRING GEN-3/0-AWG-THWN-2-CU-BLK WR5-6 40 FEET 1 3/0 AWG THWN-2, COPPER, BLACK (LINE 2) WIRING GEN-3/0-AWG-THWN-2-CU-WH WR5-6 40 FEET 1 3/0 AWG THWN-2, COPPER, WHITE (NEUTRAL) WIREWAY GEN-EMT-0.75'' DIA WW2-5, 7 60 FEET 1 EMT CONDUIT, 0.75'' DIA WIREWAY GEN-EMT-2'' DIA WW5-6 40 FEET 1 EMT CONDUIT, 2'' DIA OCPD GENERIC MANUFACTURER GEN-CB-60A-240VAC CB1 1 PIECE 1 CIRCUIT BREAKER, 60A, 240VAC OCPD GENERIC MANUFACTURER GEN-CB-200A-240VAC CB2 1 PIECE 1 CIRCUIT BREAKER, 200A, 240VAC TRANSITION BOX GENERIC MANUFACTURER GEN-AWB-TB-4-4X JB1-2 2 PIECES 1 TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKS DISCONNECTS INVERTERS OCPDS ASHRAE EXTREME LOW -25.9°C (-14.6°F), SOURCE: BARNES MUNI (42.16°; -72.72°) ASHRAE 2% HIGH 32.7°C (90.9°F), SOURCE: BARNES MUNI (42.16°; -72.72°) REF.QTY.RATED CURRENT MAX VOLTAGE CB1 1 60A 240VAC CB2 1 200A 240VAC REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222URB OR EQUIV.60A 240VAC REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1 1 SOLAR EDGE SE10000H-US (240V) ENERGY HUB INVERTER WITH PRISM TECHNOLOGY (240V)240V FLOATING 60A 10000W 42A 27A 480V 99.0% POWER OPTIMIZERS MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-35 35 JA SOLAR JAM54S31-395/MR 395W 368.7W 13.7A 12.81A 36.98V 30.84V -0.102V/°C (-0.28%/°C)20A REF.QTY.MODEL RATED INPUT POWER MAX OUTPUT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY PO1-35 35 SOLAR EDGE P401 400W 15A 14.65A 60V 98.8% SYSTEM SUMMARY INVERTER #1 STRING #1 STRING #2 STRING #3 POWERBOX MAX OUTPUT CURRENT 15A 15A 15A OPTIMIZERS IN SERIES 9 12 14 NOMINAL STRING VOLTAGE 400V 400V 400V ARRAY OPERATING CURRENT 8.89A 11.85A 13.83A ARRAY STC POWER 13,825W ARRAY PTC POWER 12,905W MAX AC CURRENT 42A MAX AC POWER 10,000W DERATED (CEC) AC POWER 10,000W E-602.00 DESIGN TABLES (SHEET 7) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 11-22-2022 (E) UTILITY METER (N) BATTERY EXTERIOR EQUIPMENT TO PV ARRAY (N) AC DISCONNECT (N) INVERTER TO (N) INVERTER TO (E) MEP (E) MEP TO (N) BACKUP INTERFACE TO (N) AC DISCONNECT INTERIOR EQUIPMENT (E) UTILITY (N) BACKUP INTERFACE (N) BATTERY GRADE FRONT BACK !CAUTION! MULTIPLE SOURCES OF POWER. THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAY AND ESS WITH SAFETY DISCONNECTS AS SHOWN: 01 EQUIPMENT ELEVATION NOT TO SCALE E-603.00 PLACARDS (SHEET 8) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 PV ARRAY ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL 1 AT EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (2" X 4"). [NEC 690.13]. POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING LABEL 2 AT POINT OF INTERCONNECTION OVERCURRENT DEVICE (2" X 4"). [NEC 705.12(B)(2)(3)(B)]. LABEL 4 AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS (5 3/4" X 1 1/8"). [NEC 690.31(G)] LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND; REFLECTIVE [IFC 605.11.1.1] RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL 5 AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2"). [NEC 690.56(C)(3)]. LABEL 9 AT EACH AC DISCONNECTING MEANS (4" X 1"). [NEC 690.13(B)]. LABEL 10 AT EACH DC DISCONNECTING MEANS (4" X 1"). [NEC 690.13(B)]. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS LABEL 3 AT RAPID SHUTDOWN SYSTEM (3 3/4" X 5 1/4"). [NEC 690.56(C)(1)(A)]. LABELING NOTES 1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. 1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE RED BACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVE YELLOW BACKGROUND. [ANSI Z535] 1.6 ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND BE WEATHER RESISTANT/SUNLIGHT RESISTANT AND CANNOT BE HAND-WRITTEN PER NEC 110.21(B) INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTED PHOTOVOLTAIC SYSTEM DISCONNECT LOCATED NORTH SIDE OF THE HOUSE DIRECTORY PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8"). [NEC 690.56(B)] WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, A DIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PV SYSTEM DISCONNECTING MEANS. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED IN BATHROOMS [NEC 690.4(D),(E)] PHOTOVOLTAIC SOLAR AC DISCONNECT CAUTION SOLAR ELECTRIC SYSTEM CONNECTED LABEL 6 AT UTILITY METER (5 3/4" X 1 1/8") [NEC 690.56(B)] WARNING TRIPLE POWER SUPPLY SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM LABEL 7 AT POINT OF INTERCONNECTION (2 3/4" X 1 5/8"). [NEC 705.12(B)(3)] WARNING SOLAR ELECTRIC CIRCUIT BREAKER IS BACKFED LABEL 8 AT POINT OF INTERCONNECTION (2" X 1"). [NEC 705.12(B)(3)] PHOTOVOLTAIC SOLAR DC DISCONNECT PHOTOVOLTAIC POWER SOURCE LABEL 12 AT EACH DC DISCONNECTING MEANS (3" X 4"). [NEC 690.53]. MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) LABEL 11 AT POINT OF INTERCONNECTION, MARKED AT DISCONNECTING MEANS (4" X 2"). [NEC 690.54] AC DISCONNECT PHOTOVOLTAIC SYSTEM POWER SOURCE RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE AMPS VOLTS 42 240 480 27 45 NEWSESS (INSIDE) MAIN DISTRIBUTION UTILITY DISCONNECT RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM PV ARRAY 11-22-2022 S-501 D5 20 11 121413151822 3 1 54 252423 8 27 2 S-501 D4 SHEET KEYNOTES 1. ROOF MATERIAL: ASPHALT SHINGLE 2. ROOF STRUCTURE: SINGLE SPAN RAFTER 3. ATTACHMENT TYPE: IRONRIDGE FLASHFOOT2 4. MODULE MANUFACTURER: JA SOLAR 5. MODULE MODEL: JAM54S31-395/MR 6. MODULE LENGTH: 67.8'' 7. MODULE WIDTH: 44.65'' 8. MODULE WEIGHT: 47.4 LBS. 9. SEE SHEET A-103 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: NO FIRE CODE ENFORCED. 11. RAFTER SPACING: 24 IN. O.C. 12. RAFTER SIZE: 2X8 IN. NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 4 IN. 15. TOTAL # OF ATTACHMENTS: 88 16. TOTAL AREA: 735.79 SQ. FT. 17. TOTAL WEIGHT: 1896.48 LBS. 18. WEIGHT PER ATTACHMENT: 21.55 LBS. 19. DISTRIBUTED LOAD: 2.58 PSF. 20. MAX. HORIZONTAL STANDOFF: 48 IN. 21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITH MODULE MANUFACTURER'S INSTRUCTIONS 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER (OR EQUIV.): IRONRIDGE 24. RAIL MODEL (OR EQUIVALENT): XR100 25. RAIL WEIGHT: 0.68 PLF. 26. MAX. RAFTER SPAN: N/A. 27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX 1. FIELD VERIFY ALL MEASUREMENTS 2. ITEMS BELOW MAY NOT BE ON THIS PAGE GENERAL NOTES ROOF SLOPE910 10 6 21 7 B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 S-501.00 ASSEMBLY DETAILS RACKING DETAIL (TRANSVERSE)D1 SCALE: NOT TO SCALE RACKING DETAIL (LONGITUDINAL)D2 SCALE: NOT TO SCALE RACKING DETAIL (TOP)D3 SCALE: NOT TO SCALE DETAIL (LONGITUDINAL)D5 SCALE: NOT TO SCALE DETAIL (TRANSVERSE)D4 SCALE: NOT TO SCALE SLIDE FLASHING, BETWEEN 1ST AND 2ND COURSE, SO THE TOP IS AT LEAST 3/4" ABOVE THE EDGE OF THE 3RD COURSE AND THE BOTTOM IS ABOVE THE EDGE OF THE 1ST COURSE. 3RD COURSE 2ND COURSE 1ST COURSE FLASHING DETAIL (TOP)D6 SCALE: NOT TO SCALE (SHEET 9) 11-22-2022 B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 R-001.00 RESOURCE DOCUMENT (SHEET 10) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 R-002.00 RESOURCE DOCUMENT (SHEET 11) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 R-003.00 RESOURCE DOCUMENT (SHEET 12) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 R-004.00 RESOURCE DOCUMENT (SHEET 13) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 R-005.00 RESOURCE DOCUMENT (SHEET 14) B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 (SHEET 15) RESOURCE DOCUMENT R-006.00 B F A DE 2 3 UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT WRITTEN PERMISSION FROM CONTRACTOR IS IN VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTIONS. NEW PV SYSTEM: 13.825 kWp ENGINEER OF RECORD 11.20.2022 DESIGN BY:I.P. M.B. SAVAGE RESIDENCE 41 HENSHAW AVE NORTHAMPTON, MA 01060 APN: 31B-171-001 PAPER SIZE: 11" x 17" (ANSI B) A CDE GH BC FGH 1 4 5 6 CONTRACTOR PHONE: LIC. NO.: DATE: CHECKED BY: REVISIONS HIC. NO.: ELE. NO.: ADDRESS:59C NORTH HATFIELD, MA 01038 INSIGHT SOLAR 4133387555 MA 192102 R-007.00 RESOURCE DOCUMENT (SHEET 16)