Loading...
21102185BR-Wein-rk-102521-ContPackOVERHANG INFO HEEL HEIGHT GABLE STUDS 2x6 0 IN. OC END CUT RETURN SQUARE REQ. ENGINEERING JOBSITE REQ. LAYOUTS JOBSITE 2 1 QUOTE LAYOUT CUTTING BRT BRT DATEBY SHIP TO 24 West St Hatfield, MA 01038 R.K. Miles-HatfieldSOLD TO (413) 247-8300 SALES REP ORDER DATE REQ. QUOTE DATE DELIVERY DATE / / / / 10/29/21 ORDER # QUOTE # TERMS SALES AREA CUSTOMER PO # CUSTOMER ACCT # INVOICE # LMCWRKMI ORDERED BY SUPERINTENDENT JOBSITE PHONE # DATE OF INVOICE 21102185BR Brian Tetreault Massachusetts / / / Rich Blais (413) 247-8314 PAGE 1 SPECIAL INSTRUCTIONS: *9/30/21 plans. *Light storage attic trusses above garage with pulldown access. *Standard heel carried. DELIVERY INSTRUCTIONS: JOB NAME: MODEL: TAG:RoofKeiter Builders Wein / 301 Prospect Heights BUILDING DEPARTMENT Roof Trusses JOB CATEGORY: Residential LOT # SUBDIV: DATE10/25/21 301 Prospect Heights Northampton, MA 01062 Wein / 301 Prospect Heights Rich Blais 10/25/21 10/25/21 / / 155 Bay Road, PO Box 945, Belchertown, MA. 01007 Phone: 413-323-7247 Fax: 413-323-5780 UFP Belchertown, LLC DESIGNER Brian Tetreault QTY TYPE SPAN LUMBER TOP BOT OVERHANG LEFT RIGHT CANTILEVER LEFT RIGHT PITCH TOP BOTID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 35.0,15.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 35.0,15.0,0.0,10.0 STRESS INCR. INFORMATION PLY LEFT RIGHT STUBO/ABASE SPAN A01 8.25 0.00 26-00-00 01-04-00 01-04-002 X 6 2 X 6 ATTIC 3 26-00-00 A01A 8.25 0.00 26-00-00 01-04-002 X 6 2 X 6 ATTIC 9 26-00-00 T01GE 8.25 0.00 26-00-00 01-04-00 01-04-002 X 6 2 X 6 COMMON 2 26-00-00 ROOF SUB-TOTAL: ACCEPTED BY BUYER PURCHASER: BY: TITLE: JOB ADDRESS: PHONE: DATE: ACCEPTED BY SELLER BY: TITLE: DATE OF ACCEPTANCE: SUB-TOTAL GRAND TOTAL Quote is based on current design values at the time of quote (lumber, EWP, hardware, etc). Should any of these values change prior to completion of this project, reserves the right to adjust the sell price accordingly. UFP Belchertown, LLC QUOTE POLICY: QUOTE VALID FOR 7 DAYS. AFTER 7 DAYS, UFP RESERVES THE RIGHT TO REVIEW / ADJUST ALL PRICING. Sealed individual truss drawings are included in the pricing. Sealed layouts, stamped bracing diagrams are NOT included BUT can be provided for an additional charge. Full payment made on net 30 day terms. No pay-if paid terms. UFP reserves the right to hold shipments if we are not paid within the agreed upon payment terms PURCHASE ORDER POLICY: Purchase orders are valid for a period of 30 days. Orders moved past a 30 day period are subject to price review to current market conditions. Conventionally Framed(adjust bearing height or heel foralignment with truss fascia)ConventionallyFramedT01GET01GEA01(3)A01A(9)24' 6"10' 6" 8' 8" 5' 4"24' 6"26' 0"26' 0"8' 0" 10' 0" 8' 0"1' 11 1/4"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" ROOF AREA 1120.39 ft²SHEATHING COUNT* 39 sheetsOVERHANGE LINES 58.47 ftRAKED LINES 90.64 ftRIDGE LINES 42.92 ftHIP LINES 0 ftVALLEY LINES 22.09 ftTrussTrax.ufpi.comThe following informationis an approximate andNOT guaranteed.(315) 253-2758(800) 488-7247(856) 767-0043(800) 488-2811(800) 333-2092(800) 828-2906(800) 842-6673(607) 563-1556UFP AuburnUFP BelchertownUFP BerlinUFP GordonUFP HudsonUFP New WindsorUFP ParkerUFP SidneyThis drawing is property of UFP Site Built, LLC.Any unauthorized use of this document withoutwritten permission is prohibited. UFP relinquishesownership of delivered product upon delivery.Owner of product must obtain UFP's authorizationprior to any alteration or modification of product;UFP will not be held responsible for anyunauthorized modifications done or costs incurredwithout prior written authorization from UFP.301 Prospect Heights Northampton, MA 01062Keiter Buildersr.k. Miles-Hatfield, MAWein / 301 Prospect Heights REVISIONSDATE DESCRIPTION DSN- - -- - -- - -- - -- - -- - -- - -- - -21102185BRSTRUC DATEJOB #:DESIGNERBRTARCH DATELAYOUT DATE09/30/21N/A10/25/21SCALE:N.T.S.THIS IS A TRUSS/COMPONENT PLACEMENT DIAGRAM (TPD) ONLY; NOTAN ENGINEERED DOCUMENT. Trusses are designed as individualbuildingcomponents tobe incorporated into the building design at the specification of thebuilding designer. See individual truss design drawings (TDD's) foreach truss designidentified on the TPD. The building designer is responsiblefor temporaryand permanent bracing of the roof and floor system and for the overall structure. The design of the support structure including but not limited to headers, beams, walls, and columns is also the responsibility of the building designer. For general guidanceregarding installation and bracing, consult "Building Component Safety Information" (BCSI) available from the SBC Association (www.sbcacomponents.com). It is the responsibility of the General Contractor to verify that the provided component layout matches the final intended construction plans, loading conditions, and use. Ifthey do not, it is the responsibility of the General Contractor to notify UFP and provide plans containing the latest specifications and designs. UFP will not be responsible for planchanges by others after final approval of shop drawings, or for errors or modifications made on-site during construction. DO NOT CUT, NOTCH,DRILL, OR OTHERWISE "REPAIR" MANUFACTURED TRUSSES IN ANY WAYWITHOUT PRIOR WRITTEN AUTHORIZATION BY A LICENSED PROFESSIONAL DESIGNATED BY UFP. The Framer is responsible to verify all dimensions, including adjusting member spacing within tolerances to allow for the drop and rise ofplumbing/HVAC, unless noted otherwise. Truss-to-wall connections, if shown, are for uplift only and do not consider lateral loads. All connectors on this project are to be installed per the connector manufacturer's specifications. All connectors shown that are not truss-to-truss are suggestionsonly and are to be verified by theBuilding Designer or Engineer of Record for suitability to this particular project. UFP accepts no responsibility for the specific application or suitability of any connector that is not truss-to-truss as they apply to this specific structure.FOR APPROVAL - ROOF PLACEMENT PLANROOF TRUSS CRITERIABUILDING CODEIRC2015SNOW LOAD35.000 lb/ft²TOP CHORD DEAD LOAD15.000 lb/ft²BOTTOM CHORD LIVE LOAD0.000 lb/ft²BOTTOM CHORD DEAD LOAD10.000 lb/ft²LIVE LOAD DEFLECTION240TOTAL LOAD DEFLECTION180LEFT END OF TRUSS IS NOTED AS(TYPICAL)ROOF TRUSS NOTES: 8.2512 =5x6 =8x8 =3x8 =5x6 =4x4 =2x4 =6x6 =4x4 =MT18HS 5x12 =5x6 =3x8 =8x8 =5x6 1 11141312 102 2522 93 84242315 5 7 6 T2 T1 T2 T1 B1 B2 W3 W4 W1 W1 W2W2 10-00-00 1-04-00 27-04-00 1-04-00 -1-04-00 2-06-09 10-04-13 2-06-09 18-01-12 2-07-03 15-07-03 2-07-03 13-00-00 3-04-10 21-06-06 3-04-10 7-10-04 4-05-10 4-05-10 4-05-10 26-00-00 7-10-04 7-10-04 7-10-04 26-00-00 10-03-08 18-01-1210-04-157-006-06-129-06-04Scale = 1:70.6 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)-0.36 12-14 >858 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.67 Vert(CT)-0.57 12-14 >545 180 MT18HS 197/144 TCDL 15.0 Rep Stress Incr YES WB 0.27 Horz(CT)0.04 10 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS Attic -0.26 12-14 >473 360 BCDL 10.0 Weight: 139 lb FT = 20% LUMBER TOP CHORD 2x6 SPF 2100F 1.8E *Except* 1-3,9-11:2x6SPF No.2 BOT CHORD 2x6 SPF 2100F 1.8E WEBS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 4-1-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 15 REACTIONS (size)2=5-08, (min. 2-09), 10=5-08, (min. 2-09) Max Horiz 2=-199 (LC 9) Max Grav 2=2017 (LC 22), 10=2017 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-22=-2996/0, 3-22=-2840/0, 3-4=-2697/0, 4-23=-1958/0, 5-23=-1842/0, 7-24=-1842/0,8-24=-1958/0, 8-9=-2696/0, 9-25=-2944/0,10-25=-2997/0 BOT CHORD 2-14=0/2539, 13-14=0/2048, 12-13=0/2048, 10-12=0/2402 WEBS 8-12=0/994, 4-14=0/993, 5-15=-2284/0, 7-15=-2284/0, 3-14=-680/152, 9-12=-680/153 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) -1-5-9 to 1-6-7, Interior (1) 1-6-7 to 10-0-0, Exterior (2) 10-0-0 to 15-11-2, Interior (1)15-11-2 to 24-5-9, Exterior (2) 24-5-9 to 27-5-9 zone;cantilever left and right exposed ; end vertical left andright exposed;C-C for members and forces & MWFRSfor reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof liveload of 16.0 psf or 2.00 times flat roof load of 35.0 psf onoverhangs non-concurrent with other live loads. 5)All plates are MT20 plates unless otherwise indicated. 6)* This truss has been designed for a live load of 20.0psfon the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Ceiling dead load (10.0 psf) on member(s). 4-5, 7-8, 5-15, 7-15; Wall dead load (5.0psf) on member(s).8-12, 4-14 8)Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-14 9)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 andR802.10.2 and referenced standard ANSI/TPI 1. 10)Attic room checked for L/360 deflection. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A01 Attic 3 121102185BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Oct 25 13:12:38 Page: 1 ID:Chwt??HuAwGqED7UtSdqlcyPteZ-Rv_rQf6ExPZce?CXR_BEgrfQJv9dRJqTjVQhb6yPtRt This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 8.2512 =5x6 =8x8 =3x8 =5x6 =4x4 =2x4 =6x6 =4x4 =MT18HS 5x12 =5x6 =3x8 =8x8 =5x6 1 13 12 11 102 21 24 3 9 4 8232214 5 7 6 T2 T1 T2 T3 B1 B2 W3 W4 W1 W1 W2W2 10-00-00 1-04-00 -1-04-00 2-06-09 18-01-12 2-06-09 10-04-13 2-07-03 15-07-03 2-07-03 13-00-00 3-04-10 7-10-04 3-04-10 21-06-06 4-05-10 26-00-00 4-05-10 4-05-10 7-10-04 7-10-04 7-10-04 26-00-00 10-03-08 18-01-1210-04-157-006-06-129-06-04Scale = 1:66.1 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.60 Vert(LL)-0.36 11-13 >857 240 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.67 Vert(CT)-0.57 11-13 >545 180 MT18HS 197/144 TCDL 15.0 Rep Stress Incr YES WB 0.27 Horz(CT)0.04 10 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS Attic -0.26 11-13 >473 360 BCDL 10.0 Weight: 137 lb FT = 20% LUMBER TOP CHORD 2x6 SPF 2100F 1.8E *Except* 1-3,9-10:2x6SPF No.2 BOT CHORD 2x6 SPF 2100F 1.8E WEBS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or4-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 14 REACTIONS (size)2=5-08, (min. 2-09), 10=5-08, (min. 2-06) Max Horiz 2=192 (LC 8) Max Grav 2=2020 (LC 22), 10=1885 (LC 23) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-21=-3002/0, 3-21=-2952/0, 3-4=-2705/0,4-22=-1966/0, 5-22=-1850/0, 7-23=-1846/0,8-23=-1962/0, 8-9=-2709/0, 9-24=-2863/0,10-24=-3020/0 BOT CHORD 2-13=0/2533, 12-13=0/2044, 11-12=0/2044, 10-11=0/2423 WEBS 8-11=0/1014, 4-13=0/993, 5-14=-2295/0, 7-14=-2295/0, 3-13=-672/151, 9-11=-709/160 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior (2) -1-5-9 to 1-6-7, Interior (1) 1-6-7 to10-0-0, Exterior (2) 10-0-0 to 15-11-2, Interior (1)15-11-2 to 23-0-0, Exterior (2) 23-0-0 to 26-0-0 zone;cantilever left and right exposed ; end vertical left andright exposed;C-C for members and forces & MWFRSfor reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow);Category II; Exp B; Partially Exp.; Ct=1.10 3)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 5)All plates are MT20 plates unless otherwise indicated. 6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 7)Ceiling dead load (10.0 psf) on member(s). 4-5, 7-8, 5-14, 7-14; Wall dead load (5.0psf) on member(s).8-11, 4-13 8)Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 11-13 9)This truss is designed in accordance with the 2015International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)Attic room checked for L/360 deflection. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply A01A Attic 9 121102185BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Oct 25 13:12:38 Page: 1 ID:DJ4RPtWt9G6LTuw4rtSku7yPtcz-Rv_rQf6ExPZce?CXR_BEgrfQ9v9eRJoTjVQhb6yPtRt This design is based upon parameters shown, and is for an individual building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFPI plant. Bracing shown is for lateral support of truss members only and does not replace erection and permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, erection and bracing available from SBCA and Truss Plate Institute. 8.2512 =4x4 =4x6 =5x6 =4x6 =4x6 =4x4 191 33 32 31 30 29 28 27 26 25 24 23 22 21 20 182 173 36 39 37 4 16343835 5 15 4847614 7 13128 119 10 T2 T1 T2 T1 B1 B2 ST6 ST6ST7 ST7 ST8 ST9 ST5 ST4 ST3 ST2 ST1 ST5 ST4 ST3 ST2 ST14-10-001-04-00 27-04-00 1-04-00 -1-04-00 13-00-00 13-00-00 13-00-00 26-00-00 26-00-0010-04-157-009-06-042-01-002-01-00Scale = 1:61.3 Loading (psf)Spacing 2-00-00 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 35.0 Plate Grip DOL 1.15 TC 0.24 Vert(LL)n/a -n/a 999 MT20 197/144 (Roof Snow = 35.0)Lumber DOL 1.15 BC 0.19 Vert(CT)n/a -n/a 999 TCDL 15.0 Rep Stress Incr YES WB 0.20 Horz(CT)-0.01 46 n/a n/a BCLL 0.0*Code IRC2015/TPI2014 Matrix-MS BCDL 10.0 Weight: 190 lb FT = 20% LUMBER TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 OTHERS 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 ocbracing. JOINTS 1 Brace at Jt(s): 34, 35, 36, 37 REACTIONS All bearings 26-00-00. (lb) -Max Horiz 2=199 (LC 10), 40=199 (LC 10) Max Uplift All uplift 100 (lb) or less at joint(s) 2, 18, 20, 22, 23, 25, 29, 30, 31, 32, 33, 40, 46 except 21=-165 (LC 17) Max Grav All reactions 250 (lb) or less at joint(s) 2, 21, 25, 27, 29, 31, 32, 40except 20=659 (LC 1), 22=310 (LC1), 23=262 (LC 19), 26=428 (LC19), 28=390 (LC 1), 30=288 (LC18), 33=315 (LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250(lb) or less except when shown. TOP CHORD 2-3=-152/459, 3-4=-115/444, 4-5=-86/440, 5-47=-57/424, 6-47=-46/435, 6-7=-48/449, 7-8=-21/457, 8-9=-66/447, 9-10=-82/322, 10-11=-82/322, 11-12=-66/447, 12-13=-21/457, 13-14=-48/449, 14-48=0/434,15-48=-4/424, 15-16=-26/449,16-17=-73/390, 17-18=-130/466 BOT CHORD 2-33=-349/184, 32-33=-349/184,31-32=-349/184, 30-31=-349/184,29-30=-349/184, 28-29=-349/184,27-28=-348/184, 26-27=-348/184,25-26=-349/184, 24-25=-349/184,23-24=-349/184, 22-23=-349/184,21-22=-349/184, 20-21=-349/184, 18-20=-349/184 WEBS 28-36=-377/1, 34-36=-387/1, 9-34=-323/4, 26-37=-417/0, 35-37=-427/0, 11-35=-363/0, 17-20=-381/76 NOTES 1)Wind: ASCE 7-10; Vult=117mph (3-second gust) Vasd=92mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) exterior zone and C-C Corner (3) -1-5-9 to 1-6-7, Exterior (2) 1-6-7 to 10-0-0, Corner (3) 10-0-0 to 16-0-0, Exterior (2) 16-0-0 to 24-5-9, Corner (3) 24-5-9 to 27-5-9 zone; cantilever left and right exposed ; end vertical left and rightexposed;C-C for members and forces & MWFRS forreactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2) Truss designed for wind loads in the plane of the trussonly. For studs exposed to wind (normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-10; Pf=35.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non-concurrent with other live loads. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Gable requires continuous bottom chord bearing. 8)Vertical gable studs spaced at 2-0-0 oc and horizontal gable studs spaced at 2-4-8 oc. 9)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 18, 29, 30, 31, 32, 33, 25, 23, 22, 20, 2, 18 except (jt=lb) 21=165. 11)Beveled plate or shim required to provide full bearingsurface with truss chord at joint(s) 2, 40. 12)This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply T01GE Common Supported Gable 2 121102185BR Job Reference (optional) UFP Site Built, LLC, UFP SE Engineering Run: 8.51 S Aug 16 2021 Print: 8.510 S Aug 16 2021 MiTek Industries, Inc. Mon Oct 25 13:12:38 Page: 1 ID:jlzxR_?TtFxGZO5UMRepiMyPtZm-Rv_rQf6ExPZce?CXR_BEgrfWuvG9RKCTjVQhb6yPtRt