Loading...
COMcheck Exterior Lighting Compliance Report-20190613_104549_152COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Title: 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency Project Type:Alteration Construction Site: 165 Bridge Road Northampton, MA 01062 Owner/Agent: Northampton Kingdom Hall 165 Bridge Road Northampton, MA 01062 Designer/Contractor: Project Information Energy Code: Northampton Kingdom Hall 2 (Residential mixed use area)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Parking Lot (Parking area)15000 ft2 0.06 Yes 900 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 900 900 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Parking Lot ( Parking area 15000 ft2): Tradable Wattage LED 5: X1.5: Philips Type 3 Site Light: LED Roadway-Parking Unit 54W:1 3 56 168 LED 6: W5: LED Other Fixture Unit 28W:1 2 26 52 220Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES Project Title: Data filename: Northampton Kingdom Hall Untitled.cck 06/13/19Report date: 51 ofPage Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 780 CMR Massachusetts State Building Code, 9th Edition, Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR8]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Completed COMcheck Exteiror Lighting certificate and Plan Review Checklist will be submitted with application. Complies Does Not Not Observable Not Applicable C405.6 [PR16]1 Group R-2 dwelling units have separate electrical meters. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Northampton Kingdom Hall Untitled.cck 06/13/19Report date: 52 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.5 [EL25]null Automatic lighting controls for exterior lighting installed. Controls will be daylight controlled, set based on business operation time-of-day, or reduce connected lighting > 30%. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Northampton Kingdom Hall Untitled.cck 06/13/19Report date: 53 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C405.5.1 [FI19]1 Exterior lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Exterior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Northampton Kingdom Hall Untitled.cck 06/13/19Report date: 54 ofPage Project Title: Data filename: Northampton Kingdom Hall Untitled.cck 06/13/19Report date: 55 ofPage