COMcheck Exterior Lighting Compliance Report-20190613_104549_152COMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Title:
780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency
Project Type:Alteration
Construction Site:
165 Bridge Road
Northampton, MA 01062
Owner/Agent:
Northampton Kingdom Hall
165 Bridge Road
Northampton, MA 01062
Designer/Contractor:
Project Information
Energy Code:
Northampton Kingdom Hall
2 (Residential mixed use area)Exterior Lighting Zone
Allowed Exterior Lighting Power
A
Area/Surface Category
B
Quantity
C
Allowed
Watts / Unit
D
Tradable
Wattage
E
Allowed Watts
(B X C)
Parking Lot (Parking area)15000 ft2 0.06 Yes 900
Total Tradable Watts (a) =
Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
900
900
600
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Parking Lot ( Parking area 15000 ft2): Tradable Wattage
LED 5: X1.5: Philips Type 3 Site Light: LED Roadway-Parking Unit 54W:1 3 56 168
LED 6: W5: LED Other Fixture Unit 28W:1 2 26 52
220Total Tradable Proposed Watts =
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting
systems have been designed to meet the 780 CMR Massachusetts State Building Code, 9th Edition, Energy Efficiency
requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection
Checklist.
Name - Title Signature Date
Exterior Lighting PASSES
Project Title:
Data filename:
Northampton Kingdom Hall
Untitled.cck
06/13/19Report date:
51 ofPage
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.1.0
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 780 CMR Massachusetts State Building Code, 9th Edition,
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR8]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the exterior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices. Completed COMcheck
Exteiror Lighting certificate and Plan
Review Checklist will be submitted
with application.
Complies
Does Not
Not Observable
Not Applicable
C405.6
[PR16]1
Group R-2 dwelling units have
separate electrical meters.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Northampton Kingdom Hall
Untitled.cck
06/13/19Report date:
52 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.5
[EL25]null
Automatic lighting controls for exterior
lighting installed. Controls will be
daylight controlled, set based on
business operation time-of-day, or
reduce connected lighting > 30%.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Northampton Kingdom Hall
Untitled.cck
06/13/19Report date:
53 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C405.5.1
[FI19]1
Exterior lighting power is consistent
with what is shown on the approved
lighting plans, demonstrating
proposed watts are less than or equal
to allowed watts.
Complies
Does Not
Not Observable
Not Applicable
See the Exterior Lighting fixture schedule for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Northampton Kingdom Hall
Untitled.cck
06/13/19Report date:
54 ofPage
Project Title:
Data filename:
Northampton Kingdom Hall
Untitled.cck
06/13/19Report date:
55 ofPage