2022-11-04 Dietz Permit-Construction Set (1)0.0 TITLE PAGE PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SET167 BAKER HILL ROAD NORTHHAMPTON, MA 01062 DIETZ RENOVATIONS Laura Fitch, AIA, LEED BD+C Fitch Architecture and Community Design, Inc. 110 Pulpit Hill Road, Amherst, MA 01002 (413) 549-5799 lfitch@facdarchitects.com 0.0 TITLE PAGE D-1.1 DEMO FIRST FLOOR PLAN D-1.2 DEMO SECOND FLOOR PLAN A-1.0 BASEMENT PLAN A-1.1 FIRST FLOOR PLAN A-1.2 SECOND FLOOR PLAN A-2.1 N+E ELEVATIONS A-2.2 S+W ELEVATIONS A-3.1 BUILDING SECTIONS A-4.1 WALL SECTIONS A-5.1 WINDOW SCHEDULE A-5.2 WINDOW SCHEDULE A-5.3 DOOR & FINISH SCHEDULE A-5.4 DOOR & FINISH SCHEDULE A-6.1 INTERIOR ELEVATIONS A-6.2 INTERIOR ELEVATIONS A-6.3 INTERIOR ELEVATIONS A-6.4 INTERIOR ELEVATIONS E-1.0 ELECTRICAL NOTES & CODE E-1.1 FIRST FLOOR ELECTRICAL PLAN E-1.2 SECOND FLOOR ELECTRICAL PLAN 4'-0"20'-6"14'-512"9'-812"4'-012"9'-3"10'-1"16'-0"9'-11"24'-1"24'-1"20'-1"13'-11"26'-1"5'-21 2"4'-01 2"48'-812"OFFICE MUDROOM DEMO SINK, COUNTER, CABINET, AND FLOORING CUT NEW ROUGH OPENING FOR DEEPER WINDOWS REMOVED EXISTING DOOR AND INFILL WALL DEMO SECTION OF WALL FOR NEW POCKET DOOR INTO MUDROOM UP UP MOVE MINISPLIT TO THE BASEMENT IF SYSTEM CHANGED TO CENTRAL AIR. KEEP EXISTING HEAT AND GO WITH SPACE PACK. SHORE UP STRUCTURE AS NEEDED FOR THE REMOVAL OF PROBABLE BEARING WALLS AND INSTALLATION OF FLUSH BEAMS REMOVE FRONT STEP FOR REPLACEMENT THIS MINISPLIT MAY BE KEPT IF SYSTEM CHANGED TO CENTRAL AIR LIVING 110 HALL #1 101 DEN 111 GARAGE 107 LAV 113 DEMO PORCH RAILS REMOVE MINISPLIT IN NEW KITCHEN. RELOCATE OR REPLACE PER SYSTEM DECISIONS DEMO DOOR AND SECTION OF WALL FOR NEW POCKET DOOR SHORE UP PROBABLE BEARING WALL FOR INSTALLATION OF FLUSH BEAM ALTERNATE PRICE: REMOVE ALL WINDOWS AND INTERIOR DOORS FOR REPLACEMENT SEE SECTION FOR NEW STRUCTURE AT EXTERIOR WALL DEMO UP DN FIRST FLOOR DEMO PLAN Scale: 3/16" = 1'-0"1 D-1.1 DEMO FIRST FLOOR PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SET D-1.2 DEMO SECOND FLOOR PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETDN BEDROOM #3 WALK IN CLOSET BEDROOM #2 BATH #2 BEDROOM #1 35'-117 8" 1'-2"12'-01 16"2'-41 2"10'-83 16"1'-2"8'-71 8"12'-11"14'-512"13'-9"REMOVE ALL BATHROOM FIXTURES AND FINISHES FOR REMODELING. PATCH WALLS, FLOORS, AND CEILINGS AS NECESSARY. REMOVE MINISPLIT IF SYSTEM CHANGED TO CENTRAL AIR DETERMINE IF THE FLOOR SHOULD BE CUT AND FLOOR JOISTS DOUBLED TO CREATE ZERO ENTRY INTO SHOWER REMOVE MINISPLIT IF SYSTEM CHANGED TO CENTRAL AIR MASTER BATH IF REPLACED, CHANGE ALL BI-FOLD DOORS TO BI-FOLD DOORS WITH SOLID CORES ALTERNATE PRICE: REMOVE ALL WINDOWS AND INTERIOR DOORS FOR REPLACEMENT HALL #2 CLOSET #4SECOND FLOOR DEMO PLAN Scale: 3/16" = 1'-0"1 A-1.0 BASEMENT PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETX0-06-GX0-07-GX0-08-G X0-05-F X0-02-D2 X0-04-G X0-03-F X0-02-F X0-01-G UP X0-03-F X0-04-F X0-05-G EXISTING CHASE? X0-01-F UP FURNACE ROOM WATER ENTRY CLOSETELEC. CLOSETX0-06-F CLO.10'-5" +/-5'-8" +/-4'-0" +/-20'-6" +/-14'-512" +/-9'-812" +/-4'-012" +/-9'-3" +/-10'-1" +/-16'-0" +/-9'-11" +/-24'-1" +/-24'-1" +/-20'-1" +/-13'-11" +/-26'-1" +/-5'-21 2" +/-4'-01 2" +/-48'-812" +/-NEW FOUNDATION WALL LAV #2 5'-6"1 A-3.1 BASEMENT PLAN Scale: 3/16" = 1'-0"1 A-1.1 FIRST FLOOR PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETX1-09-C3 X1-13-D X1-14-H X1-12-D X1-10-DX1-11-D X1-04-F X1-05-A X1-03-F X1-02-F 4'-0"20'-6"14'-512"9'-812"4'-012"9'-3"10'-1"16'-0"9'-11"24'-1"24'-1"20'-1"13'-11"26'-1"5'-21 2"4'-01 2"48'-812"UP LIVING 110 HALL #1 101 DEN 111 GARAGE 107 LAV 113 X1-15-F UP DN X1-11-D2 1 A-3.1 1-06-E 1-07-G UP DN 1-08-D KITCHEN 105 1-03-C DINING 106 REPLACE EXISTING TALL WINDOWS WITH HIGH ONES OVER COUNTER (NO UPPER CABINETS AT WINDOWS) 1-13-E 1-01-A 1-08-C2 REPLACE EXISTING SLIDER WITH NEW WINDOWS NEW OR MODIFED EXISTING DOOR TO REVERSE SWING 1-01-A MUDROOM 104 PANTRY 103 RELOCATED EXISTING GARAGE DOOR AND STEPS 1-05-B REPLACE BAY WITH NEW SHORTER BAY WITH SHELF FLUSH WITH NEW KITCHEN COUNTERS UPUP UP 1-04-F HOLD NEW WALL BACK TO CLEAR EXISTING DOOR TRIM THREE WALL REMOVALS: INVESTIGATE STRUCTURE AT SECOND FLOOR FRAMING AT WALL REMOVAL. INSTALL FLUSH BEAM IF POSSIBLE. PATCH ALL FINISHES AT FLOOR, CEILINGS AND WALLS 1-06-J2 1-07-C2 NEW BRICK VENEER TERMINATING AT NEW POSTS AT EDGE OR PORCH CONSIDER COVERING EXISTING STOOP WITH STONE AND PROVIDING MORE GRACIOUS FRONT STEP(S) DW CLOSET #1 109 PORCH 101 LIVING 107 HALL #1 102 DEN 108 GARAGE 100 LAV 110 NEW WINDOWS AND DOORS SHOULD HAVE LHGC 1-14-B 1-12-B 1-10-D3 1-09-D2 NEW PEDESTAL SINK ONE OPERABLE FRENCH DOOR WITH TWO FIXED PANELS ONE OPERABLE FRENCH DOOR WITH ONE FIXED PANEL REPLACE WITH WINDOWS 1-02-B UTILITY SINK THICKEN THE WALL AND LET THE DOOR SLIDE BEHIND THE NEW UTILITY SINK SO THAT CABINETS CAN BE MOUNTED ON THE WALLS 3 245 2 432 PIN SMALL WALL STEM TO THE FLOOR AND CEILING AT INTERSECTION WITH NEW POCKET DOOR 1-15-A1 FRIG. WIDEN AND DEEPEN EXISTING WINDOW R.O. FOR (2) DH WINDOWS SMALL WOODED OR CONCRETE STOOP TBD COATS SM BROOM CLOSET NEW WOOD FLOORING FIRST FLOOR ~1,015 SQ FT TOTAL FIRST FLOOR PLAN Scale: 3/16" = 1'-0"1 1 A-6.1 1 A-6.3 1 A-6.2 A-1.2 SECOND FLOOR PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETX2-12-F X2-01-G X2-03-G X2-04-D X2-05-D3 X2-06-D X2-07-E X2-08-GX2-09-G X2-11-E X2-12-E X2-10-E X2-10-F X2-09-F X2-07-G X2-06-F X2-05-F X2-11-F DN X2-03-F BEDROOM #3 WALK IN CLOSET BEDROOM #2 BATH #2 BEDROOM #1 35'-117 8" 1'-2"12'-01 16"2'-41 2"10'-83 16"1'-2"8'-71 8"12'-11"14'-512"13'-9"HALL #2 CLOSET #4X2-01-G X2-02-G CLOSET #4208WH 2-04-B WALK IN CLOSET 203 NEW SOLID SURFACE COUNTER WITH INTEGRATED BOWLS AND CABINET UNDER NEW CLOSET SHELVING BY OTHERS NEW FREE STANDING TUB WITH FAUCET AT END INFILL WINDOW NICHE WITH 2 CUSTOM SHELVES TILED FOR PLANTS, SOAP, ETC. HALF HEIGHT WALL (MATCHING HEIGHT OF TILE WAINSCOT) WITH GLASS ABOVE MASTER BEDROOM 201 MASTER BATH 202 NEW TILED 4'6" X 3'0" SHOWER BASE AND SURROUND RETAIN 12" MIN AT BEDROOM CLOSET FOR SHELVING X2-08-G 352 4 SHOWER DOOR OPENS TOWARD ENTRY DOOR TANKLESS WATER HEATER WITH ACCESS PANEL BEDROOM #3 207 BEDROOM #1 204 BATH #2 206 BEDROOM #2 205 HALL #2 200 CLOSET #2209CLOSET #3210NEW ROOF OVER NEW BAY WINDOW BELOW NEW WOOD FLOORING SECOND FLOOR ~855 SQ FT TOTAL 1 A-3.1 SECOND FLOOR PLAN Scale: 3/16" = 1'-0"1 1 A-6.4 A-2.1 N+E ELEVATIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETA D D D GG GG GG GG GG REMOVE ALL PIPING TO MINI SPLITS IF SYSTEM IS CHANGED TO CENTRAL AIR REPLACE PORCH WINDOWS WITH SINGLE NARROW AWNING APPROXIMATELY 60X18 NEW PAINTED BRICK AT ENTRY CONSIDER REMOVING ALL SHUTTERS F F D FIRST FLOOR 0'-0" SECOND FLOOR +/-8'-10"BOTTOM OF CEILING 8'-0" TOP OF DECK -0'-7"T.O. GARAGE SLAB -1'-6" 1 A-3.1 PROPOSED NORTH ELEVATION WITHOUT SHUTTERS Scale: 3/16" = 1'-0"1 3 A-2.1 D2 D H GGGGGG B NEW OR RELOCATED EXISTING LIGHT FIXTURE PROPOSED EAST ELEVATION WITHOUT SHUTTERS Scale: 3/16" = 1'-0"2 REMOVE RAILINGS REMOVE ALL SIDING REMOVE WINDOWS F DEMO NORTH ELEVATION Scale: 1/4" = 1'-0"3 A-2.2 S+W ELEVATIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETJ2 B GG GG D C2 REMOVE ALL PIPING TO MINI SPLITS IF SYSTEM IS CHANGED TO CENTRAL AIR REPLACE EXISTING SLIDING DOORS WITH NEW WINDOWS PATCH ALL FRAMING AND FINISHES AND INSULATE BELOW NEW WINDOW GG D A NEW EXTERIOR OUTLET REPLACE EXISTING EXTERIOR LIGHTS NEW OR RELOCATED EXISTING LIGHT FIXTURE NEW SHORTER PREFABRICATED BAY WINDOW, PATCH ALL FRAMING AND FNISHES AND INSULATE BELOW F NEW FULLY INSULATED AND FINISHED ROOF AND FLOOR SURROUND AT NEW PREFAB. BAY UNIT FULLY FLASH NEW BAY AND REPAIR SIDING AS NEEDED. HOLD SIDING A MIN. OF 2" ABOVE ROOFING. TOP OF PLATE TOP OF PLATE 1 A-3.1 PROPOSED SOUTH ELEVATION WITHOUT SHUTTERS Scale: 3/16" = 1'-0"1 D3C3 D3 C2D2 F REPLACE EXISTING WINDOW WITH (2) TALLER WINDOWS PATCH ALL FRAMING AND FINISHES AND INSULATE BELOW NEW WINDOW D2 GG FF GG FIRST FLOOR 0'-0" SECOND FLOOR +/-8'-10"BOTTOM OF CEILING 8'-0" TOP OF DECK -0'-7"T.O. GARAGE SLAB -1'-6" PROPOSED WEST ELEVATION WITHOUT SHUTTERS Scale: 3/16" = 1'-0"2 A-3.1 BUILDING SECTIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETD2 B D GG GG GG H AAA1 5'-6"11'-0" +/-5'-0" +/- LAUNDRY PANTRY 4'-0"MIN.B NEW SLEEPER/LEDGER ON TOP OF EXISTING ROOF SHEATHING CUT EXISTING EAVE AND INSTALL NEW FLUSH BEAM TO CARRY EXISTING ROOF LOAD DASHED LINE OF EXISTING EXTERIOR BEARING WALL TO BE REMOVED SECTION THRU MUDROOM & PORCH Scale: 3/16" = 1'-0"1 1 A-4.1 A-4.1 WALL SECTIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SET1'-0" +/- MATCH TO EXISTING EAVE OF GARAGE 12 2 8'-1"+/-TOP OF PLATENEW ROOF CONSTRUCTION: - ON R-9 ZIP SHEATHING - ON 2x10 JOISTS AT 24" OC - NEW FLUSH FRAMED BEAM AT FORMER BEARING WALL - 3" CLOSED CELL FOAM - FILL REMAINDER OF CAVITY WITH DPC - GYPSUM BOARD CEILING EXISTING ROOF CONSTRUCTION TBD NEW WALL CONSTRUCTION: - SHINGLES TO MATCH - ON R-9 ZIP SHEATHING - ON 2x6 STUDS - 5.5" DENSE PACKED CELLULOSE - INTERIOR FINISH TBD MEMBRANE AT LOW PITCH ROOF AREA DECK OR STOOP, TBD ISOLATE NEW SLAB8"MIN.4'-0"MIN.FORM A 4" WIDE NOTCH IN THE FOUNDATION WALL FOR INSULATION OF 2" RIDGID FOAM EDGE INSULATION 4"4" TYP. FOOTING DRAIN: - 4" PERF. PIPE TO DAYLIGHT OR AREA DRAIN - GRAVEL BACKFILL - FILTER FABRIC BASEMENT FLOOR CONSTRUCTION: - 4" CONCRETE SLAB - ON 6 MIL. POLY VAPOR BARRIER - ON 2" XPS RIGID INSULATION - ON 6" GRAVEL W/ SUB-SLAB RADON MITIGATION SECTION THRU NEW MUDROOM WALL Scale: 3/4" = 1'-0"1 2 A-4.1 3 A-4.1 4 A-4.1 DETAIL Scale: 1 1/2" = 1'-0"2 MATCH EXISTING DETAIL Scale: 1 1/2" = 1'-0"3 4"2"6"CERAMIC TILE BASEBOARD FLASH BETWEEN WALL AND ICF INSULATION DETAIL Scale: 1 1/2" = 1'-0"4 INSTALL A NEW SLEEPER LEDGER ON EXSITING SHEATHING FOR NEW RAFTER TIE IN ADD FLUSH BEAM, SIZE TBD. CONNECT INSULATION TO STRUCTURE WITH CLOSED CELL FOAM FLASH INSTERSECTION BETWEEN TWO ROOF SECTIONS A-5.1 WINDOW SCHEDULE PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETOperation Type/SHGC Glass Safety Width Unit Height Unit Protection Fall Manufacturer Notes Awning 5'0"1'6" Complex 2'8"3'4" Complex 6'0"4'0" Complex 6'4"5'5" Complex 6'4"5'5" Double Hung 3'0"3'1" Double Hung 3'0"4'8" Double Hung 3'0"4'8" Double Hung 3'0"3'1" Double Hung 3'0"4'8" Double Hung 3'0"3'1" Double Hung 3'0"3'1" Double Hung 3'0"3'1" Double Hung 3'0"4'8"CONFIRM SIZE Double Hung 3'0"4'8"CONFIRM SIZE Double Hung 3'0"4'8"CONFIRM SIZE Complex 9'3"5'5"3 UNITS Double Hung 3'0"5'1" Double Hung 3'0"5'1" Double Hung 3'0"5'1" Double Hung 3'0"5'1" Double Hung 2'0"3'1" Double Hung 3'0"3'1" Double Hung 3'0"3'1" Double Hung 3'0"3'1" Double Hung 3'0"5'1" Double Hung 9'3"5'1"3 UNITS Double Hung 3'0"5'1" Double Hung 3'0"3'9" Double Hung 3'0"3'1" Double Hung 3'0"3'1" Double Hung 3'0"3'9" Double Hung 3'0"3'9" Double Hung 3'0"3'9" The locations specified in Sections R308.4.1 through R308.4.7 shall be considered to be specific hazardous locations for the purposes of glazing. Glazing in fixed and operable panels of swinging, sliding and bifold doors shall be considered to be a hazardous location. 1. Glazed openings of a size through which a 3-inch-diameter (76 mm) sphere is unable to pass. 2. Decorative glazing. Glazing in an individual fixed or operable panel adjacent to a door shall be considered to be a hazardous location where the bottom exposed edge of the glazing is less than 60 inches (1524 mm) above the flooR... and it meets either of the following conditions: 1.Where the glazing is within 24 inches (610 mm) of either side of the door in the plane of the door in a closed position. 2. Where the glazing is on a wall perpendicular to the plane of the door in a closed position and within 24 inches (610 mm) of the hinge side of an in-swinging door. Glazing in an individual fixed or operable panel that meets all of the following conditions shall be considered to be a hazardous location: 1. The exposed area of an individual pane is larger than 9 square feet (0.836 m2), 2. The bottom edge of the glazing is less than 18 inches (457 mm) above the floor, 3. The top edge of the glazing is more than 36 inches (914 mm) above the floor, and 4. One or more walking surfaces are within 36 inches (914 mm), measured horizontally and in a straight line, of the glazing. 3. Outboard panes in insulating glass units and other multiple glazed panels where the bottom edge of the glass is 25 feet (7620 mm) or more above grade, a roof, walking surfaces or other horizontal [within 45 degrees (0.79 rad) of horizontal] surface adjacent to the glass exterior. Glazing in walls... and enclosures... containing... bathtubs and showers... where the bottom exposed edge of the glazing is less than 60 inches (1524 mm)... above any standing or walking surface shall be considered to be a hazardous location. This shall apply to single glazing and each pane in multiple glazing. Glazing that is more than 60 inches (1524 mm), measured horizontally and in a straight line, from the water’’s edge of a bathtub... or from the edge of a shower... Window fall protection shall be provided in accordance with Sections R312.2.1 and R312.2.2. In dwelling units, where the top of the sill of an operable window opening is located less than 24 inches (610 mm) above the finished floor and greater than 72 inches (1829 mm) above the finished grade or other surface below on the exterior of the building, the operable window shall comply with one of the following: 1. Operable windows with openings that will not allow a 4-inch-diameter (102 mm) sphere to pass through the opening where the opening is in its largest opened position. 2. Operable windows that are provided with window fall prevention devices that comply with ASTM F 2090. 3. Operable windows that are provided with window opening control devices that comply with Section R312.2.2. Window opening control devices shall comply with ASTM F 2090. The window opening control device, after operation to release the control device allowing the window to fully open, shall not reduce the net clear opening area of the window unit to less than the area required by Section R310.2.1. 1. Existing rough openings to be confirmed in the field 2. Windows by Pella, with natural wood interior finish and aluminum clad exterior, black. 3. Provide alternative price for triple glass windows. A-5.2 WINDOW SCHEDULE PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETA 5'-0"1'-6"C2 6'-8"6'-4"5'-5"B 8'-01 2"3'-4"PRE-FABRICATED BAY UNIT D 3'-0"+/- I.D.5'-1"+/- I.D.E 3'-0"+/- I.D.3'-9"+/- I.D.C3 9'-3"+/- I.D.5'-5"+/- I.D.F 3'-0"+/- I.D.4'-8"+/- I.D.6'-8"D3 5'-1"+/-9'-3"+/- I.D. TYPICAL WINDOW NOTES 1. 2. DIMENSIONS TAKEN ON SITE FROM INTERIOR STOP TO INTERIOR STOP AND INTERIOR HEAD TRIM TO EXISTING SILL ALL WEST AND EAST FACING WINDOWS SHALL HAVE HIGH SHGC NEW FULL FRAME UNITS REPLACEMENTS INSERT UNITS PROVIDE ALTERNATE PRICES GG 3'-0"+/- I.D.3'-1"+/- I.D.H 2'-0"+/- I.D.3'-1"+/- I.D.6'-8"BASE BID A-5.3 DOOR & FINISH SCHEDULE PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETUnit Size WidthHeightDoor Operation Location Rating Door Fire Glazing Hardware Finish Manuf.Comments 3'0"6'8"Swing Simple EXT./HALL #1 LOW-E DEADBOLT 3'0"6'8"Pocket Simple MUDROOM/KITCHEN PASSAGE 5'0"6'8"Pocket Bi-part PANTRY/MUDROOM PASSAGE 3'0"6'8"Swing Simple GARAGE/MUDROOM 1 HOUR PASSAGE 1'8"6'8"Swing Simple MUDROOM/SMALL BROOM CLOSET PASSAGE 4'0"6'8"Swing Bi-part MUDROOM/COAT CLOSET PASSAGE 3'0"6'8"Swing Simple EXT./MUDROOM LOW-E DEADBOLT 5'8"6'8"Slider EXT./DINING LOW-E BY MANUFACTURER 8'10"6'8"Slider EXT./DINING LOW-E BY MANUFACTURER 3'0"6'8"Pocket Simple HALL #1/DEN PASSAGE 2'0"6'8"Swing Simple HALL #1/CLOSET PASSAGE 2'6"6'8"Pocket Simple LAV/HALL #1 LOCKING 3'0"6'8"Swing Simple EXT./HALL #1 LOW-E PASSAGE (SCREEN DOOR)STORM/SCREEN COMBO 2'6"6'8"Pocket Simple WIC/MASTER BEDROOM PASSAGE 2'6"6'8"Swing Simple BASEMENT/LAV #2 LOCKING 6'0"6'8"Swing Bi-part EXT./BASEMENT LOW-E DEADBOLT 2'6"6'8"Swing Simple BASEMENT/FURNACE ROOM PASSAGE 2'6"6'8"Swing Simple WATER ENTRY CLOSET/BASEMENT PASSAGE 4'0"6'8"Swing Bi-part ELEC. CLOSET/BASEMENT PASSAGE 2'8"6'8"Swing Simple CLOSET/BASEMENT PASSAGE 3'0"6'8"Swing Simple EXT./GARAGE 1 HOUR LOW-E DEADBOLT 5'10"6'8"Swing Bi-part EXT./DEN LOW-E DEADBOLT 2'8"6'8"Swing Simple HALL #1/BASEMENT STAIRS PASSAGE 6'0"6'8"Swing Bi-part BEDROOM #3/CLOSET PASSAGE 2'0"6'8"Swing Simple MASTER BEDROOM/MASTER BATH LOCKING 2'6"6'8"Swing Simple MASTER BEDROOM/HALL #2 PASSAGE 2'6"6'8"Swing Simple BEDROOM #2/HALL #2 PASSAGE 4'0"6'8"Swing Bi-part BEDROOM #2/CLOSET PASSAGE 4'0"6'8"Swing Bi-part BEDROOM #1/CLOSET PASSAGE 2'6"6'8"Swing Simple BEDROOM #1/HALL #2 PASSAGE 2'2"6'8"Swing Simple HALL #2/BATH #2 LOCKING 2'0"6'8"Swing Simple HALL #2/CLOSET PASSAGE 2'6"6'8"Swing Simple BEDROOM #3/HALL #2 PASSAGE 100 GARAGE EXISTING N/A N/A EXISTING & NEW PATCH PAINT EXISTING N/A PATCH EXISTING FINSIHES 101 PORCH NEW STONE N/A N/A NEW BRICK N/A EXISTING PAINT REPAIR EXISTING FINISHES 102 HALL #1 NEW HARDWOOD NEW WOOD PAINT EXISTING & PATCHED GYP. BOARD PAINT EXISTING PAINT 103 PANTRY NEW TILE NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 104 MUDROOM NEW TILE NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 105 KITCHEN NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 106 DINING NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 107 LIVING NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 108 DEN NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 109 CLOSET #1 NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 110 LAV NEW TILE NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 200 HALL #2 NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT OPEN UP LOW CEILING AREA 201 MASTER BEDROOM NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 202 MASTER BATH NEW TILE NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 203 WALK IN CLOSET NEW HARDWOOD NEW WOOD PAINT EXISTING & NEW PATCH PAINT EXISTING & NEW PATCH PAINT 204 BEDROOM #1 NEW HARDWOOD NEW WOOD PAINT EXISTING PAINT EXISTING PAINT 205 BEDROOM #2 NEW HARDWOOD NEW WOOD PAINT EXISTING PAINT EXISTING PAINT 206 BATH #2 NEW TILE NEW WOOD PAINT EXISTING PAINT EXISTING PAINT 207 BEDROOM #3 NEW HARDWOOD NEW WOOD PAINT EXISTING PAINT EXISTING PAINT 208 CLOSET #4 NEW HARDWOOD NEW WOOD PAINT EXISTING PAINT EXISTING PAINT 209 CLOSET #2 NEW HARDWOOD NEW WOOD PAINT EXISTING PAINT EXISTING PAINT 210 CLOSET #3 NEW HARDWOOD NEW WOOD PAINT EXISTING PAINT EXISTING PAINT GENERAL NOTES 1. 2. REPLACE ALL THE INTERIOR DOOR AND WINDOW TRIM THROUGHOUT SCRAPE POPCORN FINISH FROM CEILING AND REFINISH- WORK DONE BY OWNER A-5.4 DOOR & FINISH SCHEDULE PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETA D2BC6'-8"A1 D D3 E F G A-6.1 INTERIOR ELEVATIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETUPUP KITCHEN 105 DW 3'-11"2'-7"3'-0"1'-0"2'-11 2"3'-10"7'-1"1'-0" 6'-7"+/-2'-1"2'-10"+/-2'-3"2'-2"3'-212"+/-432 4'-9"+/-5"2'-6"2'-6"11 2"3'-0"1 2" 31 2" DRYER VENT FRIG. KITCHEN Scale: 1/2" = 1'-0"1 B2B1D 3'-3"1'-6"6'-7"+/- VERIFY IN FIELD ADJUST WIDTH AS NEEDED TO CENTER SINK BASE CABINET ON WINDOWS 3'-0"2'-0"2'-9"3'-0"3'-0"2'-1"+/- KITCHEN Scale: 1/2" = 1'-0"2 B B1 KITCHEN Scale: 1/2" = 1'-0"3 KITCHEN Scale: 1/2" = 1'-0"4 A-6.2 INTERIOR ELEVATIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SET2'-5"1"1'-6"4'-10"2"2'-10"1"2'-10"1"2'-10"2" TV REPLACE FIREBOX SURROUND WITH BLACK SLATE REPLACE HEARTH WOOD AREA. WOOD HOLDER BY OWNER LIVING ROOM Scale: 1/2" = 1'-0"2 2 5" 2"2'-10"1"2'-10"1"2'-10"2" CONSIDER CHANGING OPENING - REVIEW THIS AND BAR WITH INTERIOR DECORATOR REFINSH FIRE BOX SURROUND RETILE HEARTH REPLACE MANTEL 24" DEEP STEREO CABINET BELOW LIVING ROOM Scale: 1/2" = 1'-0"1 C3 1'-0"1'-0"4'-10"1'-6"1"2'-5"LIVING ROOM Scale: 1/2" = 1'-0"3 A-6.3 INTERIOR ELEVATIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETUP 10'-0"5'-0"2'-0"4'-812"2'-7"312"3'-1012"3'-1012"312"8"3'-1"312"3'-11"2'-7"3'-0"1'-0"2'-11 2" 6'-7"+/- 3 245 4'-9"+/- FREEZE PROOF SILL COCK DRYER VENT BUILD OUT WALL FOR POCKET DOOR- EXTEND ONLY AS FAR AS LOWER SINK COUNTER MUDROOM Scale: 1/2" = 1'-0"1 B MUDROOM Scale: 1/2" = 1'-0"2 EE G PROBABLY 2 OR 4-PANEL DOORS, TBD F MUDROOM Scale: 1/2" = 1'-0"5 A CONSIDER (2) CUSTOM BASE CABINETS (2'5 1/2") TO MAKE EVEN 2'-6"2'-6"1"2'-4"2'-6" 1'-0"1'-51 2"5'-0"1'-51 2"1'-0"112"3'-6"1'-6"2'-1112"MUDROOM Scale: 1/2" = 1'-0"4 D MUDROOM Scale: 1/2" = 1'-0"3 UNDER CABINET LIGHTING A-6.4 INTERIOR ELEVATIONS PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETWH 352 4 BUILD WALL OUT WITH INSTANT HOT WATER WITHIN. ACCESS PANEL IN CLOSET GLASS SHELVING BY OWNER 2'-5"31 2"1'-2"41 2"2'-41 2"3'-2"312"3'-1"312"2'-712"5'-101 2"6'-0"5'-21 2" 5'-101 2"+/- MASTER BATHROOM Scale: 1/2" = 1'-0"1 MASTER BATHROOM Scale: 1/2" = 1'-0"2 6'-0" 2'-3"1'-51 2"2'-3"1"MASTER BATHROOM Scale: 1/2" = 1'-0"4 F SINGLE GLASS SHELF BY OWNER MASTER BATHROOM Scale: 1/2" = 1'-0"3 MASTER BATHROOM Scale: 1/2" = 1'-0"5 E-1.0 ELECTRICAL NOTES & CODE PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETSYMBOL KEY 3 SMALL CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE OVER BATHROOM SINK EXTERIOR, WALL MOUNTED FIXTURE DUPLEX OUTLET, GFC IN WET LOCATIONS EXT = EXTERIOR OUTLET AC = ABOVE COUNTER GFC = GROUND FAULT CIRCUIT SWITCH 3 = 3 WAY SWITCH D = DIMMER WALL WASHER SPECIAL PURPOSE OUTLET TELEPHONE DATA SMOKE DETECTOR UNDER CABINET LIGHT CEILING FAN TUBULAR SKYLIGHT 4' LED CEILING MOUNTED FIXTURE CEILING OR WALL MOUNTED FIXTURE OVER CLOSET DOOR DATA / VOICE TV TV / CABLE CEILING OR BEAM MOUNTED TRACK LIGHT EXHAUST FAN CO DETECTOR INTERIOR WALL SCONCE EXTERIOR, WALL MOUNTED FLOOD LIGHT - 1 LAMP EXTERIOR, WALL MOUNTED FLOOD LIGHT - 2 LAMPS HEAT DETECTOR UC T FL FL B F SD CO HD CL PE SD SD CO PHOTOELECTRIC SMOKE DETECTOR COMBINATION SMOKE / CO DETECTOR LARGE CEILING MOUNTED/SUSPENDED FIXTURE QUAD OUTLET CEILING FAN/LIGHT COMBO FL UC EXHAUST TO ERVERV SUPPLY FROM ERVERV EXIT SIGN EXIT SIGN WITH DIRECTIONA; HORN/STROBE STROBE KNOX BOX WITH SIGNAL LIGHT PULL STATION ENUNCIATOR/CONTROL PANEL EMERGENCY LIGHTING (SINGLE) EMERGENCY LIGHTING (DOUBLE) H/S S KB PS EP SYMBOL KEY 3 SMALL CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE OVER BATHROOM SINK EXTERIOR, WALL MOUNTED FIXTURE DUPLEX OUTLET, GFC IN WET LOCATIONS EXT = EXTERIOR OUTLET AC = ABOVE COUNTER GFC = GROUND FAULT CIRCUIT SWITCH 3 = 3 WAY SWITCH D = DIMMER WALL WASHER SPECIAL PURPOSE OUTLET TELEPHONE DATA SMOKE DETECTOR UNDER CABINET LIGHT CEILING FAN TUBULAR SKYLIGHT 4' LED CEILING MOUNTED FIXTURE CEILING OR WALL MOUNTED FIXTURE OVER CLOSET DOOR DATA / VOICE TV TV / CABLE CEILING OR BEAM MOUNTED TRACK LIGHT EXHAUST FAN CO DETECTOR INTERIOR WALL SCONCE EXTERIOR, WALL MOUNTED FLOOD LIGHT - 1 LAMP EXTERIOR, WALL MOUNTED FLOOD LIGHT - 2 LAMPS HEAT DETECTOR UC T FL FL B F SD CO HD CL PE SD SD CO PHOTOELECTRIC SMOKE DETECTOR COMBINATION SMOKE / CO DETECTOR LARGE CEILING MOUNTED/SUSPENDED FIXTURE QUAD OUTLET CEILING FAN/LIGHT COMBO FL UC EXHAUST TO ERVERV SUPPLY FROM ERVERV EXIT SIGN EXIT SIGN WITH DIRECTIONA; HORN/STROBE STROBE KNOX BOX WITH SIGNAL LIGHT PULL STATION ENUNCIATOR/CONTROL PANEL EMERGENCY LIGHTING (SINGLE) EMERGENCY LIGHTING (DOUBLE) H/S S KB PS EP Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area in the immediate vicinity of the bedrooms. 3. On each additional story of the dwelling, including basements and habitable attics and not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 4. Smoke alarms shall be installed not less than three feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by section R314.3. 5. For each 1,000 ft of area or part thereof. 6. Near all stairs. A single heat detector listed for the ambient environment shall be installed in: 1. Any garage attached to or under the dwelling (detached garages do not require a heat detector). Carbon monoxide alarms in dwelling units shall be outside of each separate sleeping area within ten feet of the bedrooms... At least one alarm shall be installed on each story of a dwelling unit, including basements and cellars but not in crawl spaces and uninhabitable attics. Combination carbon monoxide and smoke alarms (in compliance with section 314) shall be permitted to be used in lieu of carbon monoxide alarms, located as in R315.3, provided they are compatible and the smoke alarms take precedence. E-1.1 FIRST FLOOR ELECTRICAL PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETUP UP DN UNDER CABINET STRIP LIGHTS DW 3 3 3 ETR AC, GFI AC, GFI AC, GFI AC, GFI AC, GFI GFI GFI ETR AC, GFI AC ACAC AC ETR 3 ETR, AT 6' ETR?ETR? INVESTIGATE EXSITING LIGHT FIXTURES, OUTLETS, ETC. 3 3 3 3 ETR EXT ETR? EXT ETR ETR? AC, GFI SD CO SD CO UNDER CABINET STRIP LIGHTS ETR EXT 3 3 3 3 EXT THIS PLAN NEEDS TO BE REVIEWED ON SITE TO LOOK AT EXISTING ITEMS TO REMAIN FL ETR ETR ETR ETRETR ETR ETR REPLACE EXISTING CEILING FAN ETR ETR ETR ETR ETR ETR SDETR NO WORK IN GARAGE - EXCEPT TO RELOCATE ANY SWITCHES AND OUTLETS AT DOOR CHANGE UNDER CABINET STRIP LIGHTS ETR ETR REPLACE RELOCATE EXISTING LIGHTS UP DN UP UP DW 3 245 2 432 FRIG. FIRST FLOOR PLAN Scale: 3/16" = 1'-0"1 SYMBOL KEY SMALL CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE OVER BATHROOM SINK WALL WASHER UNDER CABINET LIGHT CEILING FAN TUBULAR SKYLIGHT CEILING OR WALL MOUNTED FIXTURE OVER CLOSET DOOR CEILING OR BEAM MOUNTED TRACK LIGHT EXHAUST FAN INTERIOR WALL SCONCE UC T B F CL LARGE CEILING MOUNTED/SUSPENDED FIXTURE CEILING FAN/LIGHT COMBO FL UC EXHAUST TO ERVERV SUPPLY FROM ERVERV DATA SMOKE DETECTOR DATA / VOICE TV TV / CABLE CO DETECTOR HEAT DETECTOR SD CO HD PE SD SD CO PHOTOELECTRIC SMOKE DETECTOR COMBINATION SMOKE / CO DETECTOR EXIT SIGN EXIT SIGN WITH DIRECTIONA; HORN/STROBE STROBE KNOX BOX WITH SIGNAL LIGHT PULL STATION ENUNCIATOR/CONTROL PANEL EMERGENCY LIGHTING (SINGLE) EMERGENCY LIGHTING (DOUBLE) H/S S KB PS EP 3 EXTERIOR, WALL MOUNTED FIXTURE DUPLEX OUTLET, GFC IN WET LOCATIONS EXT = EXTERIOR OUTLET AC = ABOVE COUNTER GFC = GROUND FAULT CIRCUIT SWITCH 3 = 3 WAY SWITCH D = DIMMER SPECIAL PURPOSE OUTLET TELEPHONE DATA 4' LED CEILING MOUNTED FIXTURE DATA / VOICE EXTERIOR, WALL MOUNTED FLOOD LIGHT - 1 LAMP EXTERIOR, WALL MOUNTED FLOOD LIGHT - 2 LAMPSFL FL QUAD OUTLET GENERAL NOTES: 1. THESE PLANS ARE SCHEMATIC ONLY - ELECTRICAL CONTRACTOR SHOULD WALK THROUGH PROJECT WITH OWNER AFTER ROUGH FRAMING TO REVIEW, CLARIFY, AND CHANGE DESIGN. 2. FIXTURES TO BE SELECTED BY OWNER AND INSTALLED BY ELECTRICIAN. 3. SWITCHES TO BE LOCATED APPROXIMATELY 5" FROM DOOR TRIM, LATCH SIDE - HEIGHT AS PER CODE. 4. OUTLETS TO BE LOCATED AS PER MIN. RESIDENTIAL CODE REQUIREMENTS. OUTLETS SHOWN ON PLAN ARE IN APPROXIMATE LOCATIONS AS DESIRED, BUT MAY NOT MEET THIS MINIMUM STANDARD. OUTLETS SHOWN ON PLAN MAY NEED TO BE SUPLEMENTED WITH ADDITIONAL OUTLETS. 5. PROVIDE POWER FOR NEW SPACEPAK AIR CONDITIONING SYSTEM AND REMOVE POWER TO ANY REMOVED MINI SPLITS AND CONDENSORS 6. KEEP EXISTING HEATING SPACEPAK FOR AC 7. REPLACE ALL OUTLET COVERS THROUGHOUT 8. REPLACE ALL LIGHT SWITCHES WITH NEW TOGGLE TYPE THROUGHOUT E-1.2 SECOND FLOOR ELECTRICAL PLAN PROJECT NUMBER: OCT. 7, 2022 22-13 DRAWN BY: REVISIONS NUMBER DATEFITCH ARCHITECTURE& COMMUNITY DESIGNHOME COMMUNITY PLANET110 PULPIT HILL ROADAMHERST, MA 01002(413) 549-5799www.facdarchitects.comDIETZ RENOVATION167 BAKER HILL ROAD,NORTHAMPTON, MA 01062PERMIT/CONSTRUCTION SETSYMBOL KEY SMALL CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE OVER BATHROOM SINK WALL WASHER UNDER CABINET LIGHT CEILING FAN TUBULAR SKYLIGHT CEILING OR WALL MOUNTED FIXTURE OVER CLOSET DOOR CEILING OR BEAM MOUNTED TRACK LIGHT EXHAUST FAN INTERIOR WALL SCONCE UC T B F CL LARGE CEILING MOUNTED/SUSPENDED FIXTURE CEILING FAN/LIGHT COMBO FL UC EXHAUST TO ERVERV SUPPLY FROM ERVERV DATA SMOKE DETECTOR DATA / VOICE TV TV / CABLE CO DETECTOR HEAT DETECTOR SD CO HD PE SD SD CO PHOTOELECTRIC SMOKE DETECTOR COMBINATION SMOKE / CO DETECTOR EXIT SIGN EXIT SIGN WITH DIRECTIONA; HORN/STROBE STROBE KNOX BOX WITH SIGNAL LIGHT PULL STATION ENUNCIATOR/CONTROL PANEL EMERGENCY LIGHTING (SINGLE) EMERGENCY LIGHTING (DOUBLE) H/S S KB PS EP 3 EXTERIOR, WALL MOUNTED FIXTURE DUPLEX OUTLET, GFC IN WET LOCATIONS EXT = EXTERIOR OUTLET AC = ABOVE COUNTER GFC = GROUND FAULT CIRCUIT SWITCH 3 = 3 WAY SWITCH D = DIMMER SPECIAL PURPOSE OUTLET TELEPHONE DATA 4' LED CEILING MOUNTED FIXTURE DATA / VOICE EXTERIOR, WALL MOUNTED FLOOD LIGHT - 1 LAMP EXTERIOR, WALL MOUNTED FLOOD LIGHT - 2 LAMPSFL FL QUAD OUTLET GENERAL NOTES: 1. THESE PLANS ARE SCHEMATIC ONLY - ELECTRICAL CONTRACTOR SHOULD WALK THROUGH PROJECT WITH OWNER AFTER ROUGH FRAMING TO REVIEW, CLARIFY, AND CHANGE DESIGN. 2. FIXTURES TO BE SELECTED BY OWNER AND INSTALLED BY ELECTRICIAN. 3. SWITCHES TO BE LOCATED APPROXIMATELY 5" FROM DOOR TRIM, LATCH SIDE - HEIGHT AS PER CODE. 4. OUTLETS TO BE LOCATED AS PER MIN. RESIDENTIAL CODE REQUIREMENTS. OUTLETS SHOWN ON PLAN ARE IN APPROXIMATE LOCATIONS AS DESIRED, BUT MAY NOT MEET THIS MINIMUM STANDARD. OUTLETS SHOWN ON PLAN MAY NEED TO BE SUPLEMENTED WITH ADDITIONAL OUTLETS. 5. PROVIDE POWER FOR NEW SPACEPAK AIR CONDITIONING SYSTEM AND REMOVE POWER TO ANY REMOVED MINI SPLITS AND CONDENSORS 6. KEEP EXISTING HEATING SPACEPAK FOR AC 7. REPLACE ALL OUTLET COVERS THROUGHOUT 8. REPLACE ALL LIGHT SWITCHES WITH NEW TOGGLE TYPE THROUGHOUT DN 352 4 3 REMOVE EXISTING HOUSE FAN AND PATCH CEILING. INSULATE AND AIR SEAL AS NEEDED. 3 REPLACE EXISTING LIGHT REPLACE OVERHEAD LIGHT WITH NEW FIXTURES AC, GFI AC, GFI 3 3 3 REPLACE (2) OVERHEAD LIGHTS AT THE CORRIDOR 3 3 REPLACE OVERHEAD LIGHT WITH CANS ADD LIGHT TO EXISTING CIRCUIT ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETRCO ETR ETR ETR ETRETR ETR ETR ETR ETR ETR REPLACE OVERHEAD LIGHT WITH NEW FIXTURES ETR ETR ETRETR ETR ETR ETR SD ETR ETR ETRETR ETRETR ETR ETR CO SECOND FLOOR PLAN Scale: 3/16" = 1'-0"1