24A-135 BP-*022-1626
22 ROE AVE COMMONWEALTH OF MASSACHUSETTS
Map:Block:Lot:
24A-135-001 CITY OF NORTHAMPTON
Permit: Solid Fuel
Appliance
PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS
DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A)
BUILDING PERMIT
Permit# BP-2022-1626 PERMISSION IS HEREBY GRANTED TO:
Project# WOOD INSERT 2022 Contractor: License:
Est. Cost: 10362 CORY MCGILL 107658
Const.Class: Exp.Date: 05/25/2023
Use Group: Owner: DELAGE MARIE-JOSE
Lot Size (sq.ft.)
Zoning: URA Applicant: CORY MCGILL DBA DONE RIGHT CH MNEY
Applicant Address Phone: Insurance:
PO BOX 1054 (413)340-1399 WCV 01525601
WILLIAMSBURG, MA 01096
ISSUED ON: 12/16/2022
TO PERFORM THE FOLLOWING WORK:
WOOD INSERT AND LINER
POST THIS CARD SO IT IS VISIBLE FROM THE STREET
Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector
Underground: Service: Meter: Footings:
Rough: Rough: House# Foundation:
Final: Final: Final: Rough Frame:
Gas: Fire Department Driveway Final: Fireplace/Chimney:
Rough: Oil: Insulation:
Smoke: Final:
THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOIATION OF
ANY OF ITS RULES AND REGULATIONS.
Signature: Ts).)2
Fees Paid: $65.00
212 Main Street,Phone(413)587-1240,Fax: (413)587-1272
Office of the Building Commissioner
The Commonwealth of Massachusetts
Board of Building Regulations and StandardsOR
DEC�E� 5 7�-uviUNICIPALITY
Massachusetts State Building Code, 780 CM1 USE
Building Permit Application To Construct, Repair, Renovate`Or-Deroe4ish-a---.-Revised Mar 2011
One-or Two-Family Dwelling
This Section For Official Use Only
Buildin Permit Number: 6A 2-3 "ft/20 Date Applied:
l? „�J 7ZSs ///2 /2-i4 ZOZZ
Building Official(Print Name) Signature bate
SECTION 1: SITE INFORMATION
1.1 Property Address: 1.2 Assessors Map& Parcel Numbers
22 toe Ave, Northampton, MA 3.YA- i 3 ts-
1.1 a Is this an accepted street?yes no Map Number Parcel Number
1.3 Zoning Information: 1.4 Property Dimensions:
Zoning District Proposed Use Lot Area(sq ft) Frontage(ft)
1.5 Building Setbacks(ft)
Front Yard Side Yards Rear Yard
Required Provided Required Provided Required Provided
1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System:
Public 0 Private 0 Zone: Outside Flood Zone?
_
Check if yes❑ Municipal 0 On site disposal system 0
SECTION 2: PROPERTY OWNERSHIP'
MOne ' f Record:
aria Hass Northampton, MA 01060
Name(Print) City,State,ZIP
22 Roe Avenue (413) 588-6656 hassm01062@gmail.com
No.and Street Telephone Email Address
SECTION 3: DESCRIPTION OF PROPOSED WORK'(check all that apply)
New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0
Demolition 0 Accessory Bldg. 0 Number of Units Other 12 Specify:wood ins& `~ Iria/ in.i tuU
Brief Description of Proposed Work2: 'To pp pore fic ‘if s (Pag r'.j C hi(YL- "Yo v to A (, et-k►W►4>rd
I(ner k.-i- codCInWcT to nei,.3 Reyenci/ W-kopplm 129si wcac1 leisvr +0 be my,�UQd.
e vY 1 a Itviou_AbeN iv bt LA mp(r ru/ pnir kv lnsa u .
SECTION 4: ESTIMATED CONSTRUCTION COSTS
Item Estimated Costs: Official Use Only
(Labor and Materials)
1. Building $1 0,362.52 1. Building Permit Fee: $ Indicate how fee is determined:
2. Electrical $ ❑Standard City/Town Application Fee
❑Total Project Cost3(Item 6)x multiplier x
3. Plumbing $ 2. Other Fees: $
4. Mechanical (HVAC) $ List:
5. Mechanical (Fire $
Suppression) Total All Fees
Check No. v Check Amount: Cash Amount:
6.Total Project Cost: $ 10,362.52 0 Paid in Full 0 Outstanding Balance Due:
SECTION 5: CONSTRUCTION SERVICES
j 5.1 Construction Supervisor License(CSL)
CS-107568 05/25/2023
- Cory McGill License Number Expiration Uatc
• — - - --
Name of('SI.Holder
List USI. I pc t see below) lJ
_P.O. Box 1054 — ---
Nu.:utJ Streel f�pe Description
l'nrestrictcd(Buildings up to 35.000 cu. It.)
Williamsburg,_ _ MA 01096__ _— _ It Restricted IK2 Famih I)vielline
('ii% '14wt.State.ZIP \I \tasonn —
RC Rooting C'o\ering
\\S \\indon and Siding
SF Solid Fuel Ilurnine Appliances
{413j 340-1399 ContactDoneRight@gmail.com I Insulation
Iekphonc Final!address 1) Ikmolilion
5.2 Registered Home Improvement Contractor(HIC) #178722 _ 08/27/2024
_ COf�( MCGII) __ _ __ Ilt1. Registration Number Expiration I)ate
IIC C'ompam Name or III('Registrant Name
P.O. Box 1054 ContactDoneRight@gmail.com
No.and Street -- - Email address --
_Williamsburg, MA 01096 (413) 340-1399 —
City.Town,State.ZIP Felcphone
SECTION 6: WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6))
Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide
this affidavit will result in the denial of the Issuance of the building permit.
Signed Affidavit Attached? Yes ® No 0
SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN
OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT
I.as Owner of the subject property.hereby authorize__ Cory_McGill _ _ _ -
to act on my behalf. in all matters relative to work authorized by this building permit application.
Maria Hass ?PtielAtitctirZ---- - �zli��2ozz
I'rint Ouncr's Name II lectronic Signature) I)ate
SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION
B) entering my name below. I hercb) attest under the pains and penalties of perjury that all of the information
contained in this application is true and accurate to the best of my knowledge and understanding.
Cory McGill 4044,99-I'rint Unner's or Authoriicd Agent's Name ectronie Signature) e
NOTES:
I. An Owner who obtains a building permit to do his her own work,or an owner who hires an unregistered contractor
(not registered in the Home Improvement Contractor(I IIC)Program).will not have access to the arbitration
program or guaranty fund under M.G.L.c. I42A.Other important information on the HIC Program can be found at
�ttt n ntas.i'u�_t°Ca Information on the Construction Supervisor License can be found at nn
2. When substantial work is planned,provide the information below
Total floor area(sq.ft.) _ _(including garage. finished basement attics,decks or porch)
Gross living area(sq. ft.) _ _ I labitable room count
Number of fireplaces __ _ _ _ Number of bedrooms
Number of bathrooms Number of half baths
1T�pe of heating*stem _ Number of decks porches
1)pe ofcooling system _ Enclosed — - -Open
3. "total Project Square Footage"may he substituted !Or"foal Project Cost"
The Commonwealth of Massachusetts
Department of Industrial Accidents
Office of Investigations
1 Congress Street, Suite 100
Boston,MA 02114-2017
•,gt www.mass.gov/dia
Workers' Compensation Insurance Affidavit: General Businesses
Applicant Information Please Print Legibly
Business/Organization Name: Done Right Chimney
Address:P.O.Box 1054,45 Main Street,Unit B
City/State/Zip:Williamsburg, MA 01096 Phone#: (413)340-1399
Are you an employer?Check the appropriate box: Business Type(required):
1.❑■ I am a employer with 5 employees (full and/ 5. Retail
or part-time).* 6. ❑ Restaurant/Bar/Eating Establishment
2.❑ I am a sole proprietor or partnership and have no 7. ❑ Office and/or Sales(incl. real estate, auto,etc.)
employees working for me in any capacity.
[No workers' comp. insurance required] 8. El Non-profit
3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment
their right of exemption per c. 152, §1(4),and we have 10.0 Manufacturing
no employees. [No workers' comp. insurance required]** 1 1.❑ Health Care
4.❑ We are a non-profit organization, staffed by volunteers,
with no employees. [No workers' comp. insurance req.] 12.0 Other Services: Chimney&Hearth
*Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information.
**If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an
organization should check box#1.
I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information.
Insurance Company Name:Atlantic Charter Insurance Company
Insurer's Address:45 Main Street, Unit B
City/State/Zip: Williamsburg, MA 01096
Policy#or Self-ins. Lic.# WCV 01525601 Expiration Date:06/28/2023
Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a
fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine
of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of
Investigations of the DIA for insurance coverage verification.
I do hereby certify,under the pains and penalties of perjury that the information provided above is true and correct.
Signature: ,ys/ Date: I 5,A,09—
Phone#: ! 13) 340-1399
Official use only. Do not write in this area,to be completed by city or town official.
City or Town: Permit/License #
Issuing Authority(circle one):
1. Board of Health 2.Building Department 3.City/Town Clerk 4. Licensing Board 5.Selectmen's Office
6.Other
Contact Person: Phone#:
www.mass.gov/dia
City of Northampton 212 Main Street, Northampton, MA 01060
Solid Waste Disposal Affidavit
In accordance of the provisions of MGL c 40, S54, I acknowledge that as
a condition of the building permit all debris resulting from the construction
activity governed by this Building Permit shall be disposed of in a properly
licensed solid waste disposal facility, as defined by MGL c 111, S 150A.
Address of the work: 22 Roe Ave., Northampton, MA 01060
The debris will be transported by: o,'ce iN\yc ejcvn
rt .(
The debris will be received by: \a‘1QLk kc,
Building permit number:
Name of Permit Applicant Nr \ 1\)1c(11\\
12-14-2022 h4aA/t/t
Date Signature of Permit Applicant
REGENCY,
CLEARANCES-MASONRY AND FACTORY BUILT FIREPLACES
The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below.
Unit Adjacent Mantle" Top Side Minimum Minimum Minimum To Top of
Side Wall (to Top of Facing Facing Hearth Hearth Hearth Side Unit
H12450 (to Side) Unit) (to Top of Unit) Extension" Thickness Extension*
A B C D E F G H
12"(305 mm) 14"(356 mm) 14"(356 mm) 1/2"(13 mm) 16"(406 mm)USA 1/2"(13mm) 8"(203 mm) 21-5/8"
for 3-1/2" (89 to side surround 18"(457 mm)Canada (548 mm)
mm)mantel
17"(432 mm)
for 12"(305 mm)
mantel
Side and Top facing is a maximum of 1-1/2"(38mm)thick.
12 10 6 6 4 2 0
1_ 11 1 1._I I_
18- 12' 305mm Mantel
16
3-1/2"(89mm
14
12 �+
10 17"
g (432mm)
14"
6 (356mm)
4
° l�10
Top Unit
d A I11111=11111:r ��III III
H IIII ' I 111
Clearances are critical. JIIII ���iV I. I.I E
I IIi�!
**Mantel can be installed anywhere in shaded
area or higher using the above scale.
Note: Ensure the paint that is used on F
the mantel and the facing is "heat
resistant"or the paint may discolour. Clearance Diagram for Installations
'Floor Protection
WOOD INSERT SPECIFICATIONS Floor thermal insulation/protection with a R value of 1.4 is required if the unit is raised 0-2.5"(0-
64mm)(measured from the bottom of the appliance).
Your fireplace opening requires the following
minimum sizes: Thermal floor protection is not required when unit is raiser greater than 2.5" (64mm) (measured
from the bottom of the appliance).
Height: 21.5'
Width: 25" Please check to ensure that your floor protection and hearth will meet the standards for clearance
Depth: 17" to combustibles.Your hearth extension must be made from a non-combustible material.Extending
16"for US and 18"for Canada—measured from the fuel loading door.
Two faceplates are available to seal the fireplace
opening:
Standard Oversize
40"W x 30"H 48"W x 34-9/16"H
(narrowest point)
42-1/2"W x 30"H 51-7/8"W x 34-9/16°H
(widest point)
Hampton'" HI2450 Wood Insert I 3
INSTALLATION INSTRUCTIONS Phone:1888-900-8106
FOR BEST-Flex Models "L", "H", "S", & "E„ Fax:888 392 4432
Q(
Web:www.NewEnglandChimneySupply.com
1111111 STAINLESS STEEL CHIMNEY LINERS ;4 Commerce Street,Williston VT 05495
ENN ell
BEST-Flex Models
Li U7 iL H 77 Li C„ Q LL E,7 BEST
7 7 J 7 FLEX
New England Supply PRODUCTS
STAINLESS STEEL CHIMNEY LINERS
BEST-Flex Models"L","H","S",&"E"Stainless Steel Chimney Liners are manufactured by New England Supply Inc.Located in Williston,VT.
The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys.BEST-Flex liners are used to vent the gases and by-products
produced by appliances that burn oil,gas,or solid fuels.
All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best
operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance.
The installer must contact the local building and fire code officials for a variety of reasons:
• The installation may require special inspection requirements.
• Building permits may be required before installation.
• Compliance with local building codes.(Authorities with local jurisdiction such as Inspectors,Municiple Building Departments,Fire Departments,and
Fire Bureau's have precedence over national codes).
For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials not specified may result
in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not
followed
BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories.
• In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys.
• In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys.
PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS
• The BEST-Flex Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new construction.
Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed
by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation.BEST-Flex can be used to vent wood,wood pellet,coal,non-
condensing gas and oil,making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available in 3"to 12"diameters
(13"above is not listed)to cover a wide range of requirements found in the field today.
• The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel,7-ply interlocked and crimped to produce
a gas and water tight lining system of superior strength and durability.BEST-Flex can be curved to go around offsets in chimneys and can be factory
ovalized to custom sizes to fit most any installation requirement.Unless specified by the manufacturer,the liner is not to be field ovalized. The
corrugated construction allows for expansion&contraction during the heat-up&cool-down periods,which removes any stresses on the system.
• BEST-Flex can be insulated with either a vermiculite based poured insulation or with a foil-faced ceramic wool blanket to meet UL 1777&ULC S635
standards for chimney exteriors with zero clearance to combustibles.
• BEST-Flex Stainless Steel Chimney Liner comes with a Life Time Warranty for all fuels,with appliance efficiencies at 83 percent or lower.
MATERIALS REQUIRED FOR BEST-Flex STAINLESS STEEL LINER INSTALLATION:
Liner Model-"L","H","S",&"E" ".
TT/TB-Two piece or one piece tee
TEC-Tee Cap
EA/EF-15°-90°elbow
C/CC-Coupler
Screws/Rivets
OPTION A OPTION B ra
Yr., j
TP-Top Plate TPCC-Liner Cap
TC Top Clamp OR TPC Top Plate OR.
SC-Storm Collar
CL-Liner Cap(square/round)
INSULATION MATERIALS REQUIRED(if applicable)
Part# Description
LI2 Liner Insulation 1/2"Foil Faced Ceramic Wool Blanket
LM Liner Mesh Protective Wire Mesh Sleeve
FT(2",3") Aluminum Foil Tape
LMC(large/small) Mesh Clamp =
BMIX BEST Mix
Phone:888-900-8106
Fax:888-392-4432
Web:www.NewEnglandChimrteySupply.com
New England Supply 34 Commerce Street,Williston VT 05495
1.)CHIMNEY PREPARATION&INITIAL INSPECTION
Before any liner can be installed the existing chimney must meet proper construction and code requirements:
• The chimney must be between 10-ft high(min)and 100-ft(max)in height.
• The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit.
• The chimney must project at least 3-k over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius.
• If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any
combustible material.If the chimney is constructed on the outside of the structure,1-in of unobstructed air space must be maintained between the
chimney mass and all other combustible materials.
• When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used.
• The installer must verify the above with all local&national codes as required.
• If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material.
• Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance.
• The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the
appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence.
• The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full
inspection must be done to determine if the chimney is structurally sound.If the existing system is found not to be in compliance with applicable
building code and I or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring
the chimney or vent into compliance with the applicable code and/or manufacturer's instructions.
Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any
applications that require a vent or chimney of a higher temperature handling capability,an alternative fuel,or any other more sever service than the original
chimney or vent in which it is installed. CHINLNEYCONXE(.1ORS:vvv\'EN CONNECTOIS
I
2.)SIZING THE CORRECT CHIMNEY LINER DIAMETER
Syste• Any heating appliance connected to the lining system must not eembuslsevra A. l,a.rasa.(wf12in.metma;nkl,»rottoo mkt
g7
151 ma l 1 ll.nn•xn aaarat¢ NrIARt:blowal Mna!Awlhat0112AI,yM^c nm)aenS 30l1ha11
have a flue outlet size larger than the liner area at its smallest :t: 11 ;7=71 him clay freer to nna�uslides Finainy Nler(ASTM 0 3.5
Illeraderet Staderd Spec haul^for Cray'Flue Le1!'s and Chnuwy PINS,or eansae^l).
point,unless a qualified person has sized the liner to suit the ..... minimum hm ue nano wall hotness.shall n:n from outer surface
r a tame wee t•,but not boycott. "urcr arfax d chimney ne
liinney
appliance tuna am het he rimer r"rea•d in Mare
• For sizing a liner used for gas and oil burning appliances refer �� »"y `TE it clearance 12 in(DS mn)
to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the unmet,)C) ,,) , Ferrite
appliance manufacturer's instructions.Liners that are incorrectly ""-pweles vmMladto NM r1
sized for the appliance can lead to poor draft,excessive
condensation,and creosote build-up inside the lining system. We/.e=we,nearer.Tom System asw5ieewalea 41,ed rectory-MO chrt,n.yleng1d6nsame
mevey b.IwN eteO e�"""red
Aasaet 2".151 mm I'� e. made l or more
as n chimney cmnecer a't05haetng)21 m.
Please call New England Supply Inc.should you have any ,,,,,.•„an air sore between
t suaonmmammmumy In length
and)
questions about sizinga liner. Feclotehan iwe aweso auspacelle wean the outer wall et morn "y and
• For sizinga liner used for solid fuel burningappliances the cross ' cre/nay arch w `°"°°°` deofthreAtlo Ceth "y""an"""`e0i" *th
PP Chevy To0rn saeol!ama masonry chimneyMeedsaa besealedbAe We
section area of the liner shall not be less than the cross section ashA11111.15.1. end to the beck maeunry pon01m00n atlh non-vale,soluble
o1 hue ( use dwnrey relr Yory cement.Supports shall be securely fastened to wail
area of the appliance outlet collar.Unless specified bythe �' --^em•hs to a"teces on al sties
PP P " Ange• ,•y - "'ox Fasteners between supports ant lee chimney length.slat not
appliance the cross section area of the flue shall not be more than }9"mmr)mn e•• a penetrate the clammy liner.
three(3)times the cross section area of the appliance outlet collar. a a;t ,,ee , Cloonan.s nt2zg nn)
,loll
Solid fuel burning fireplace liners should be a minimum of one- shwa wet str•es
twelfth(1112)the square inches compared to the square inches
of the fireplace opening.This one-twelfth(1/12)number can I.e.,chnhh Oahe .shoe--+ System c.Sheet steel clammyen tor.mmm,m24gauge[3024:n
varybased on height of the chimneyalongwith other calculating1e t51 ow.etai"" '"� Twemdv.ak j0"auge10 t1d10 """a rrmanveestatB05d 0 00 0Inn enema.
9 ;to 24 czar to zd o e min), a having w 'in
factors.Call New England Supply Inc.if you have any questions. ;EN i '''ZS""' (25 'an cry separatedh 0nnbusleies by a mermen
[�j y� r_� f 6 (157 )Mgt fiber d lion.Owing shall be covered,
�/� , ,Y a ad bwnd2 s ppotioa m sheet Mel support m n mum 24 gauge
W/i [ft Ma In a 61 1 al
3.)DETERMINE IF THE LINER SIZED IN STEP#2 WILL FIT INTO ,, .„ — Supcons seen be securely lo wet set on an sties
and shalt ee sized to fa and bad dnmrey section Foslenets.rsad
THE CHIMNEY ✓ £M ," su' to secureeta:nosyn«tion aitnot penetrate ehiwneyfleknot
Mn wane.rt ;- ror eeuamn
• The BEST-Flex Stainless Steel Chimney Liner can be installed ",tunas ,,, ntl,�„B5, (�' Clearance s n.ns2 meal
inside the existing flue tile or the flue tile can be removed.It a ,•t MM...
to NMI2i1 4te.Aawpp m
is critical that the correct size liner will actually fit into the flue.
Chimney construction and flue offsets may change the physical wwn.nd.nwy r>ossn„shamed e„ppeb ant systIm O.50400a tated.toed factory-boa dummy length ant an node
cmAsUales 2".fe1 min) dameler 2 in.(51 Tem target than Wechimney connector and having
size of the interior of the chimney.It is best to test the smallest r j tml25 min)or mnr.ainsdaeon.sewing as a pass.peoug6 for a single
,-4Lera�s daanre 2:n.Tit owl wen street Meer chimney nonnec!or of intran 24 gauge(0024 n.
point of the chimney interior before trying to install the chimney IL •p••" of_, 10.e,n,nit • .wthan,arrwm2n.sl,ntrnl„rspaceoewea,me
liner.Lower a shortpiece of the correct size liner down the ,-•�"t"'y i." 'e:2 le '"`e ery'�"chimney"•"1,and`°"' °"es.
_ tt" Mewrarn tengln d ch;mrgy sachet,maw be 12 to(365 min).Chimney
chimney to see if it will fit through,or a liner guide cone.If the cry sndwtranch/Mr wnh and spaced 1 h;25 min)away tram corned.by
m�f ®1 means of steel steel support Mates on both 00antis a dumney seol,ai
chimney liner needs to be insulated extra space around the liner ep' " Opening am)bei corm.aryl.n,n,�.9C.00supponedonbothsideswell
n I " ray convect. sheet steel supports M Farman 24 gauge!0024 in(061 mil ladiness.
is required.If a round liner configuration will not fit the liner can be Ile-_ l 26 e-.\ce•eanrane Supoatsslut oe securely fastened to wan eonaeasonan ales
`dinepee?n 15t raw t end shall be sled to fit ant bold chtm1ey sheen.Fasteners used
formed into an oval shape to fit at the factory. However an oval �srn...inn,`-- to secure dummy section shall nor paaalales imneym,nlaer
elltA
liner will change the cross section area and a larger liner may be otossuteea2t' cloaat,ee:2I(51then)
needed.Please call New England Supply Inc.with any questions.
Note/at clearances and titaneaa s are mnirmtms;tergerdeerences and thicknesses are permitted.
4.)INSTALLING THE BEST-FLEX STAINLESS STEEL CHIMNEY LINER
• Thimbles must be in the proper location to maintain the required clearance to combustibles from the connector pipe to the appliance. The liner
length is determined by measuring from the lowest thimble(if more than one)to the top of the chimney.Add approximately Six(6)inches to attach
the crown and top hardware.Cut the liner to the desired length.
• If a liner is not long enough a coupler may be used to join two pieces of liner.Attach the Coupler to the liner with the affixed band,or stainless steel
screws(Male end down when applicable).
• Attach the Tee Body to the liner with the affixed band,or stainless steel screws.If the liner needs to be insulated with a ceramic wool blanket,install
the blanket at this point. Attach the Tee Cap to the Tee Body at this point.
• Expand the draw band on the Tee Snout completely,slide the Tee Snout into the thimble with the draw band centered in the flue.Lower the liner