Loading...
17C-275 BP-2022-1526 8 COSMIAN AVE COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 17C-275-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1526 PERMISSION IS HEREBY GRANT:D TO: Project# 2022 SOLAR Contractor: License: Est. Cost: 24208 VALLEY SOLAR LLC CSL115680 Const.Class: Exp.Date: 04/09/2025 Use Group: Owner: JUNG PATRICIA ISABEL &JULIA C I VAN Lot Size (sq.ft.) Zoning: URB Applicant: VALLEY SOLAR LLC Applicant Address Phone: Insurance: 116 PLEASANT ST, SUITE 321 (413)584-8844 EXT 217 376140840101 EASTHAMPTON, MA 01027 ISSUED ON:12/07/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 17 PANEL 6.8 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIO ATION OF ANY OF ITS RULES AND REGULATIONS. Signature: � 1 • Jr . 1 •i ' II Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner Department use only ,`,.,01:! r4ev,, City of Northampton Status of Permit: ,,; ,.- ' Building Department Curb Cut/Driveway Permit 't�� 212 Main Street Sewer/Septic Availability 't..,,,' ' ' . 1' Room 100 Water/Well Availability Northampton, MA 01060 Two Sets of Structural Plans -,X— "� phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: This section to be completed by office 8 Cosmian Avenue Map (-7 C_ Lot 27. Unit 00 Florence, MA 01062 Zone Overlay District Elm St.District CB District SECTION 2- PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Julia Chevan 8 Cosmian Avenue, Florence, MA 01062 Name(Print) z Current Mailing Address (413) 687-7141 It ,, 4--- Telephone Signa ut re 2.2 Authorized Agent: Valley Solar LLC 116 Pleasant Street, Easthampton, MA 01027 Name(Print) Current Mailing Address Pa u.c4E. . ZC-rxLme...4- 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars) to be Official Use Only completed by permit applicant 1. Building $16,945 (a) Building Permit Fee G1 2. Electrical $7,263 (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= (1 +2 + 3 +4+ 5) $24,208 Check Number 0-7.67 6r This Section For Official Use Only BuildingPermit Number: 139-ZOZ2 - 15 2(v Date Issued: � Signature: / �/ 2 `/ C� 2,Oz 2 Building Commissioner/Inspector of Buildings Date lhasbrouck @ northamptonma.gov info(a valley$olar.solar EMAIL ADDRESS (REQUIRED; LIT"r^ I IOMEOw NE fl OR CON ACTO Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: .. L: R. Rear Building Height Bldg. Square Footage Open Space Footage (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW 0 YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DON'T KNOW 0 YES Q IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO Q DON'T KNOW YES Q IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained Q Obtained Q , Date Issued: C. Do any signs exist on the property? YES Q NO Q IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO Q IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling) over 1 acre or is it part of a common plan that will disturb over 1 acre? YES Q NO Q IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House n Addition ❑ Replacement Windows Alteration(s) C Roofing n Or Doors E Accessory Bldg. ❑ Demolition ❑ New Signs [D] Decks [C] Siding [O] Other[X solar Brief Description of Proposed Installation of 17 panel roof mounted solar array, system size 6.8kW DC Work: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION -TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Julia Chevan , as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf, in all matters relative to work authorized by this building permit application. I 11/22/2022 'Sigrigthre of Owner Date I, Valley Solar LLC , as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Patrick D. Rondeau Print Name 11/22/22 Signature of Owner/Agent Date SECTION 8 -CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder Patrick D. Rondeau License Number 53 Fox Farm Road, Florence MA 01062 CS-115680 Address Expiration Date Pant,c,,, Zaltd aa- 4/9/2025 Signature Telephone 413-584-8844 9.Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date 116 Pleasant Street, Easthampton, MA 01027 Telephone 413-584-8844 10/27/22 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes V{ No ❑ City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 8 Cosmian Avenue, Florence, MA 01062 The debris will be transported by: Valley Solar LLC The debris will be received by: Valley Recyling, Northampton Building permit number: Name of Permit Applicant Valley Solar LLC 11/22/22 �ors, Date Signature of Permit Applicant 1 tie e.ommonweaun of iviassucnuseaas tt Department of Industrial Accidents R (s Office of Investigations Lafayette City Center 14. - ,' 2 Avenue de Lafayette, Boston, MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print Legibly Business/Organization Name: Valley Solar LLC Address: 116 Pleasant Street, Suite 321 City/State/Zip: Easthampton, MA 01027 Phone #:413-584-8844 Are you an employer? Check the appropriate box: Business Type(required): 1.El I am a employer with 30 employees (full and/ 5. ❑ Retail or part-time).* 6. Restaurant/Bar/Eating Establishment 2.❑ I am a sole proprietor or partnership and have no 7• U Office and/or Sales(incl. real estate, auto,etc.) employees working for me in any capacity. [No workers' comp. insurance required] 8. Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑ Entertainment their right of exemption per c. 152, §1(4),and we have 10.0 Manufacturing no employees. [No workers' comp. insurance required]** 11.0 Health Care 4.U We are a non-profit organization, staffed by volunteers, with no employees. [No workers' comp. insurance req.] 12.❑■ Other Solar *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. **If the corporate officers have exempted themselves,but the corporation has other employees,a workers'compensation policy is required and such an organization should check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance Company Name: Continental Indemnity/AUW Insurer's Address: 120 Mountainview Blvd City/State/Zip: Basking Ridge, NJ 07920 Policy#or Self-ins. Lic. # 376140840101 Expiration Date:09/01/2023 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under §25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to S 1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office c f Investigations of the DIA for insurance coverage verification. I do hereby certify, under the pains and penalties of'perjury that the information provided above is true and correct. Signature: t Z7 /ytc .c Date: 11/22/22 Phone 413-584-8844 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(check one): 1.DBoard of Health 2.0 Building Department 30 City/Town Clerk 4.0 Licensing Board 50 Selectmen's Office 6.❑Other Contact Person: Phone #: LING /�►� 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Coleman D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.corn November 8, 2022 Ken Trappen Advanced Solar Solutions 2372 Morse Avenue#912 Irvine, CA 92614 Re: Engineering Services Chevan Residence 8 Cosmian Avenue, Florence, MA 6.800 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed 2x6 dimensional lumber at 25" on center. Roof Material: Metal Roof Roof Slope: 33 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 IRC, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent S-5! installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. System will be attached to the metal roofing material utilizing the patented S-5! Connection. Installation of the connections shall be in accordance with the manufacturer's recommendations. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 32"on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly yours, ,.� �.. Qj/vj „,,, Scott E.Wyssli , PE MA License No. 505 , / iti---- 1 Signed 11/8/2022 NYSSONSULTINGLING PARCEL MAP GOVERNING CODES DESIGN CRITERIA PROJECT LOCATION GPS COORDINATES(42.336117,-72.674541 APPLICABLE BUILDING CODES:. BUILDING OCCUPANCY:R-3 3,.,..., I— • 201.5 INTFRNATIONAI.BUILDING CODE I,LJ • - o 1 ''''' 111 2015 INTERNATIONAL FIRE CODE ASCE 7-10 WIND SPEED: 117 _ I 2020 NATIONAL ELECTRIC CODE I- {n ----- EXPOSURE CATEGORY:Exposure C SNOW LOAD:40 0 t a' a SNOW EXPOSURE:N/A LLJ CONSTRUCTION TYPE:VB 00 1 •- U m Lug .....__�_.....___._____ SCOPE OF WORK ROOF MOUNTED PV(SOLAR) PROJECT GRID-TIED - `a W 0 W/O BATTERY STORAGE ca o 0 R 11111 PROPOSED SOLAR EQUIPMENT T SITE/PROJECT DETAILS > a It QTY. EQUIPMENT DESCRIPTION/MEG/MODEL CONNECTION LINE-SIDE TAP ' re 17 MODULES REC400NP3 Slack ,SYSTEM SIZE DC 6.800 KW 11111 17 INVERTER(S) Enphase K38PLU5 72-2-US i SYSTEM SIZE AC S 100 KW _.....-_-- _....... _..' _..__ SHEET INDEX N/A MOUNTING IronRldgeXR100 Rail QTY.STRINGJCK7. 2 '-- -- -- '--- MIM , 48 STANCHIONS S 5I S S F. I ELECT.SERVICE 120/240V,18) SHEET SHEET TITLE I I _N/A RSD DEVICE IVTFGRAT'n IN INV ROOF COVERING Standing Metal Sewn- _. Z ! N/A BATTERIES N/4 _ _ — PV•001 COVER SHEET fMI PM 1 1 COMBINER(S) Enphase Energy X-IQ-AM1.240-4 TILT 33' N-001 GENERAL-NOTES filiM {E) MSP RATINGS 125A BUS/100A MAIN BREAKER AZIMUTH 238° PV-100R PV ARRAY LAYOUT tJ n • Inil • PROJECT TEAM LIST s-100 RACKING LAYOUT F tQ�LIBARQR ELECTRICAL UTILITY• S-200 SECTION ELEVATION 0 S-201 ATTACHMENT DETAILS > •- a g Valley5ola National Grid r L._... I DRIVEWAY 340 Riverside Dr E-001 EQUIP.CALCULATION 1— ro or METER NUMBER:47363954 E-002 WIRE AND COND.CALCS 0 , m n Florence,MA 01062 • r[, CONTRACTOR UCH:21134A PHONE: E-OLt3 THREE LINE DIAGRAM 0 ,., u 00 03 COSMIAN AVE PHONE:(413)584-8844 E-100 ELECTRICAL LAYOUT S a CONTACT NAME:Lilian Wanpku AUTHORITY HAVING NORTH PHONE:(413)588.8185 JURISDICTION: P-0O1 STANDARD PLACARDS o w Z EMAIL:production@valleysolar.solar BUILDING:City of Northampton P-002 DYNAMIC PLACARDS ao a T>: cc a PROJECT APN: • PHONE: R-lxx EQUIP.CUT SHEETS D zoo a a a GENERAL PROJECT&JURISDICTIONAL NOTES DESIGN BY: ENGBVEE ys BY- Jesse Brekelbau Scott E.Wsling CiJessem fil INSPECTION REQUIREMENTS JURISDICTIONAL&LISTING REQUIREMENTS PHONE:(413)588 8185 76 North Meadowbrook Dr a v o m 1.WHEN APPUCABLEA SMOKE DETECTOR,APPROVED AND LISTED BY 7/IF : d' N G V 1.A LADDER SHAI.1.BEIN PLACE FOR INSPECTION INCOMPLIANCE WITH AU STATE FIRE MARSHAL ORANSIAJL217 CERTIFIED TO NATIONAL(IRE ALARM I EMAIL:production@Valleysolar,solar Alpine,l1T84DD4 Q m OSHA REGULATIONS. AND SIGNALING CADS,NEPA 7I SHALL BE VE RIFTED FUNCTIONAL OR INSTALLED I UCENSE If:50507 ••� 8 > 2.PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE IN ALL APPUCSBLECOVE REQUIRED MCAT IpK, N ¢ 8 .•1 PROJECT DRAFTER: UCENSE TYPE:Civil o AU ELECTRON(ENCLOSURE DEAD FRONTS,COVERS,DOORS,ETC,SHAI E RE 2 ALLArPUCABLE EQUIPA:E NT TO BE SE UStED ORLWStED BYOIHER rn O c OPEN AND ACCESSIBLE FOR INSPECTIONS.WHEN TRENCIT AMT ROOF INSPECTIONS IIRSDICTHLNAI AND UTILITY APPROVED ASSOCIATION Oft NATIONALLY Advanced Solar Solutions PHONE:(202)874-3483 m a ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE TCR INSPECTOR. RECOOTNQED CMGANIZATIUN. 2372 Morse Ave II912 EMAIL:swyssling@wysslingconsulting.com o 3. FULL SCOPE Of WORE SHALL COMPLY WITH ALL APPLICABLE CODES LISTED Irvine,CA 92614 LL IN GOVERNING CODES SECTION,Alt MANUFACTURES'USUNGS,INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND IIRISDICTIONAI.REQIREMENTS. Ar 4 REVISED PLANS WILL BE REQUIRED TOBE RESVNMITIEU TOTHE LOCAL ADVANCED >-S $oLAR SOLUTIONS t;N Of [. URISOC'ION If THE INSTALLED ARR AY AND ASSOCIATED EQUIPMENT DOES - 'w ! NO/MACH IHE APPROVED BINDING PLANS ADDITRNNAL FEES MAY ALSO !. Ara.. PHONE:559.321-7000 n ,. EMAIL:info@adv ermits.com E V O g S HE PLACEMENT OT*UTILITY W PRODVC'IWN METER SHALL HE T`RCIVIIEC ` p llR�� E N ggg AND man is,THE CONTRACTOR AS PER APPEICABL E Until,/OR Hill ♦ T �.,.=...F REQUIREMENTS HOME OWNER PROJECT LOCATION: l 2re ...f''0 Chevan,Julia `' N} > "`"�*�„ ' 8 Cosmian Ave,Florence,MA 01062 / COPYRIGHT NOTICE ..... ... , t Uli 1.INALRHORIIDD USE OF THIS DRAWING SETSLDTHO117 EXPRESSED CONTACT NAME:Chevan,Julia rtTTtTTy� ��let. WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF US.COPYRIGHT LAWS AND WRII.BFSUBECT PHONE' Signed 11/8/2022 O CIVIL DAMAGES AND PROSECUTION. EMAIL: PV AC DISCONNECT LOCATED ON ACCESSIBLE FXTFRIOR NOTE:ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 2015 IFC ROOF ACCESS REQUIREMENTS WALL WITH EXTERNAL HANDLE VISIBLE.LOCKABLE& LABELED WIOIIN 10 FEET OF THE METER A.TMS SHIFT REPRESENTS 1HE SDI DU AR MODULE LAYCRIT ON ROOFTOP, D SHADED DASHED LNE NEAT PERIMETER Of STRUCTURE EXTERIOR IS 0 - - AN APPROX!MATF REPRFSENTADON OF I HF EXTERIOR WAIL LOCATION . / p,PHOTOVOLTAIC M000ICS ARE SCALED IN PLAN VIEW AND MAY NOT J RE AN AIURAI FIT SIaL En REPRESENTATION OF THE ACTTIAI.SCALE E...AND C.EOMFTRy OF THE PHOTOVOLTAIC MODULE.ACTUAL.PHOTO '. VOLTAIC MODULE DIMENSIONS ATE ON SHEET E-DDl Ni W Q I C.FOR THE PURPOSE OF CLARITY,AIL ElfCTRL(AI.LAYOUT DETAILS ARF aCC i LOCATED ON SHEET E-100. 0p cc VI 1- qm K VT N N N�y I-N EL 0o CD O -I .y T w d K 1 SECTION I •• Z \1\1 rf'- J' V N I-PV SITE LAYOUT LEGEND g it ,,LL�� y 0 SttTION PV ARRAY TAG Cy ROOT ACCESS POINT N Q r�' SFCPONII 0 SITE ACCESS (] 5 c 1 MODULE GROUP " I... N Rj GATE ACC ESS 0 C'� C r N W f/' AZIMUTH AND TILT TABLE a o U coLX1 LL .--' SECTION I AZIMUTH ROOF PITCH/TILT Y / SECTION 1 238...................................330...................................... m 2 W RE Z ,, to < 0 CIa ,_ r' Z a a r ,� rr '' -- -- ---- s N a ,r'' k.AAAA Q v ''. , r 0 co ' ► ._____________.____ --________...- a ',-„ o N. ,r fV ir u m O .l�rr ' RP SQUARE FOOTAGE CALCULATIONS RN o tom° W '. .. ROOF REFERENCE SQUARE FOOTAGE /r 3 is z . IX 1110 Rtw 1691 ® SECTION 1 362 ....._ __ ,. rTT1T s;®Led 1 va+za22 -._...._ ....1O L. ...I TOTAL PERCENTAGE 21.41% > i, Iii 'EXISTING DIMENSIONS ARE APPROX. CONFIRM ALL DIMENSIONS SHOWN i WY 17 REC400NP3 Black MODULES, CITY 17 Enphase IOBPLUSJ2-2,US MICRO INVERTER NORTH SCALE:1/8"=1'D"@ SHEET SIZE A3 I SHEET NOTES ♦— A.ran MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF D / OAT TO A.12,THE HORIZONTAL ANCHOR SPACING SHAH NOT 0 EXCEED 2'•8'AND ANCHORS II ADJACENT ROWS SHALL BE >„ STAGGERED UNI.F5SNO1E0 OTHERWISE PER RACKINGMANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS, H.- J L. R o. z 8. ANCHDRSARE ALSO KNOWN AS"STANDOFFS:"MOUNTS; rX' — OR—STANCHION,..NORRONIALANUHOR SPA(:ING IS AISU 0 L KNOWN AS'(.ROSS-SLOPE'OR.EAS EVE SH AN(:HON y H U� SPACINGS.MAXIMUMHANCHORZONTAI ANCHOR SPACING SHOWN u3�" < INDITA!1.AMISS NOTED OTHERWISE PER MC MI; _ go• cr MAM/FACTIMERCERTIFITTI ENGINEERED PRO(X!CT AND 0 Cr I Or Al.REOU!REMENTS.SCE N ,_,,,,_._�._ .................. 'TABUOF DIMEN40NS'EACH IX(TION DE TARP D FOR H./ IR'RIIONTAI.ANCHOR SPACING. NR Lu C. SEE SFIFFT S 2RR FOR SPED ITC MC RIND COMPONENT 1.- MANUFACTURERS 0 O ID i a 1 i VI i PV RACKING LEGEND °C L._...._....__._.__......_..__............................t ROOT RALXMG RAIL {_.._....1 ROOF RACKING MI!.SPLICE I 12.-6" TV.._...• PV ARRAY TAC 3 SFANC A(NING SECTION i EnSTANC: HION WI """""""""""' SEC DOMR I RETRO T!T!'LASHING 1 1 MODHlf GROUP z DFTARS iN Tf}P V'EW g O /�' EXISTING ROOF CONSTRUCTION U .^r'' ,:'' COMPONENT TYPE — LNo .r:" ...._..� ......_.._. acnNSTMxT1!ON E Rafter-Simple Attic 75"0C a . (.� ' C' / TMMING INFO ]"z5" ZS"MAX IX ........_............._.... 0 A Q ✓ c3��e.,.....,--..'"0 ., > - ag .{/T/ ROUL RIG COVERING Standing Metal Seam 0 3 _.,"--0! MCKING;MAX PST 2.82 PSI O C S. C/ Y ''r RACKING BILL OF MATERIALS(BOM) S w a m __. COMPONENT WY 1 MODEL LENGTH U co LL P.AR 1 I Y .- A./ PV RAIL SP_:.CE T O yl f3 w r. PV RAA2 O w w ZI m / U / u PVP.M.5,U(E2 to Z 00 00 ¢! In ,A.' RAIL TO ROOF Q Q 1 ,r O r rC7 ry o hal�c y� . n et /-ci • O/f '' a a umi Set lkr Y; P N o Fr Orr%, O ",r e c v , Y ((Z1�1 O 0 ,Y--f LL' [j.-'/[7 jjj� Signed t 1t8/2022 ...Ir Y J To —_ A EXISTING ROOF DIMENSIONS ARE APPROX. # CONFIRM ALL DIMENSIONS SHOWN =1 QTY 17 REGWDNP3 Black MODULES, CITY 17 EFNFhase IQBPLU5-72-2 U5 MICRO INVERTER NORTH SCALE:1/8"=1'0" SHEET SIZE A3N. 1 l SIMPLE ATTIC/RAFTER-PORTRAIT TscALE:NTS 2 a SIMPLE ATTIC/RAFTER-LANDSCAPE SCALE NTS SHEET NOTES in (�—�� A THFSr NOTES AP PI Y TO RAF TER ROOF ENSTR(C:TION. O 2 13 I•II RIOLXING REWIRED 2 13LDCK•IF eMG Ittut 011) V R. DIE ROOF tTR TURF t rxur)RMcu TO R(n(nmr,EOM F„ 5-201 5-201 Ir1IC,C MEN?,T Mr.T T T..A,R..CT C. 1)1F ROOF Stir AT HMG IS All FAST 7/111 i111C.KORNNT ID 1- W _ STRAHII HOARD N(MYwfx)D.1NSKiP SHE AT,IlNo is J Ill RISES i•01)------1� -•_PV1 © 12 _,5,.�_. --el/1 ACREPTARIA. (I • 5-201 i $i4 t S • 1 _ "S 2O1 D. !HE SULK{ARRAY DISPLACES NOtx LIVE LOADS(TEMPORARYet - _�-.-'",.--- 7 -` yam- CONSTRUCTION!O(R)Tt1AT THE ROCA'WAS(MKINAI IV et 0 ..-„_ - '- F 1 =�_`` `��SJ- DESIGNED i0 CARRY. v� Z r N .. (. LU,j "`•wy-- Via `,t. 1D2 �ii 1f 1HE ROOF COVER/NG IS SHINGLES;It SHALL RE NO MORE R TT^^-- y 2 } 't• - .. '"0'�+ -- / 1HAN TWU LAYERS ISHOWN) O LLI N y._ a �FRAVING Q O�_ - `' 1.rRA1WNfi r , al]\\\\ j\\\ 3" If ROOF LOVERMC 1S IRE;115 A SINGLE LAYER.ALL IILES ON fr `WDGE REAM ` D3--- -10 .. "'"o4 , I .IO0*REAM O'-' `O ".... ........„4: 'OO w„' PIANI OFPVR tMPONINTS ARE WORE. N °• INO SHOWN IN UE LI o ..... ........ ..-... _._.. ....:. ..... - G. THE X()UF S MIXTURE IS StRUC7URALLY SOUND,WI!HOW Q' SIGNS OF ALI ERAT'ONS OR SWNIt PLAN r STRUCTURALCD A. HSl .y Hid Hsl LOP-' DETFRRIRAnuxonsarmxr CI `; CD HVR1IONIAL SPAN ,�1 HORIZONTAL SPAN ('1 H. Till PV MOODIES ARP PARAI IF I.WITH 1111-ROOF SURFACE - I VI I. MERE IS A2'TO 1U"GAP IIEIWIFN UNDERSIDE OF M(xxllF > •'COMP SHINGLE ROUT IN EXAMPLE.SAME AI IACHMEN)I'(RI 5IANUING SLAM ME FALR001 APPLIES. .•COMP SHINGLE RW4IN EXAMPLE.SAME A HALF MENTIUR${AWING SEAM METAL ROCK APPLIES. AND THE ROOF SURFACE.(SFr TANK OF OMCN%I(NS'till K TABLE OF DIMENSIONS TABLE OF DIMENSIONS I. UPStOPE AWN U)R SPA(ING MAY VARY FROM LISTFIITAROTS STANCHIONS EAN RE PI.ACED NO CI OSFR THAN M.O.C. DIM COMPONENT NS M DIMENSIO D COMPONENT DIMENSIONS DIM COMPONENT I DIMENSIONS DM i COMPONENT DIMENSIONS F. OEIAIS SHOWN ARE A WET'RESENIAIION Or EIISIING ROOF , CONOITUNS.ACTUAL FIELD C1NDOTONS MAY VARY(*TAILS OM OVERHANG IN TIIKATCO 1--- - RT RIDGE REAM FTPTII OUT OVERHANG IN THIS AREA .... A7 •'WIG." :".((N. ._... ARE SHOWN FOR DIAGRAM USE ONLY.RV ER 70 TABLES TOR 33' R1 PAFTrRnfPMrl116ARIA 6 RISE Mr* 33" rV P\1rTrPI 1,1+ARIA ..-_..6n RISC ROOF PITCH • I DESIGN CRITERIA Ill PV MODULE 1RiT.ABOVE Pl%::F 1 I HST HORIZONTAL SPAN 3"-6"TYP { 11'-4" fil P't MLX!L:IE 11GT ABOVE ROOF 3"-6"TYP �Is� ',KA:ION-TM SPAN 11'-4" I. AlAll.?I l!M1H!MiANO ROOF WEFTS YIAII NOT P.E tNiSTR11CTfD Z MAX RAFTER SPAN 1 11.-4" I1S1 HrINITONTAI.SPAN MAXRATTER WAN 11'4" 1:S1 lenevoNikt.SPAN EN PV MODULES AND WOMEN T. M. URLOPE ANCHOR SPACING UPS M ANCHOR SPAON6 CL _....DI /LAIL OVERHANG..... .................. 18.7" CO STANCHIONuc 37,65" D1 1R OVERHANG 10.23" D: 51M1MONO.c. 20.7" N— Lc D2 STAIICN O.C. ,_.... 37.4" DA MIN./MAX.STSTANCHIONO.C, D.2 STANL'ITI NON. A jAMNJMAO.ST 20.45" DANC)It(NN O.C. { 1- NO 0 — _ 0 ar o 3 STANCHION DETAIL SCALE:NTS 4 STANCHION SPACING DETAIL SCALE:NTS PV RACKING LEGEND 1 H (I Di 1..........._.._..__..._................_..._................1 ROOF RACKING RAIL. (] �'E u 2 2'-8" L—) ROOF RACKMNG RAIL SPOILS C = a o N 'r MAX 0." i*� ROOF RACKING SECTION PVARR.AYTAG CL t U co EL uAANCtI!ON W/ SECTIDIII 3 V -- 117, • RETRUFITFLASHING - 1 MUUL11E GROUP Y yI ml ye, € •DETAILS IN SECTION OR SIDE VIEW m W Z 1 I ! � "" .I EXISTING ROOF CONSTRUCTION Pt eL m z ¢ ¢ d E.f N. COMPONENT TYPE e II .. ,. MEAYRN'IFH 1NiA% 25 ' ,. N Q 3 .I ►`���� S RC FINI WT R N Standing Metal Seam a o TABLE OF COMPONENTS (Yi Q ga signed 11/8/2022 " > Thimi • 1 A HD COMPONENT MODEL N i7 m �F •� eg IN Oa —s •© tiEI 1 PV RAY TYPE.1 XRIOD Rail et c m V. 1 PV RAN SPIK•E TYPE 1 PER MR MANUFACTURER _________ / ........_....._....... .. ..... ....._ 'r ............._. .._........_ IL 3 PV RAILTYPE 2 NOT USED..... .._z _ LL RA _..... . I A ^V RAIL SP OLE TYPE 2 PER RAIL MANUFACTURER I I® • ® 4 • ® S STaNC.LION 0-5 F. y y+y,p fi FIASHING N/A WEsR..ra j 7 MID CLAMP PER RAIL MANUFACTURER Y. General Notes: I END CLAMP PER RAIL MANUFACTURER " • J 1.S-5-E Clamp J~" 2.M8-1.25 Stainless Steel Hex Flange Bolt(13mm Socket) *4 _ •. I > ^.Q,. 3.3/8-24 Stainless Steel Round Point Setscrew (3/16 Hex Drive) /� N. 4.Example roof -'`i STANCHION l.._ ..................._.............................._STANCHION ATTACHMENT DETAIL [SCALE NTS-4 RAIL SPLICE DETAIL-HORIZONTAL RAIL SCALE:NTS SPIFFY NOTES1.4 • � 1 L.AMNIMUMO Ill 5/1H'DAME If RLAG SCREWS WITH 2.5" Q '' I EMBEDMEUF!MO THE R IFFRU5TH,OR THE ANCHOR ♦- PV DULE, nt FASTENER MUST MEET THE MANIA rVXE.N'S ENGINEERING. 1.1.1 2 ADHERE TO RACKING MANUFACTURERS iNSTAIIATION 0 BY OTHERS p MODULE END INSTRUCTIONS PER TAINING TO CANT INCR. t CLAMP Z lL XR 100 RAIL ) 6 > ` ....._.#. rr .. .....__ o x J '‘STAGGER STANCHIONS WHERE POSSIBLE. , SEE SHEET"S-100"FOR: ^' 1.11•• N L-FOOT HORIZONTAL ANCHOR SPAN a • __ 1'(E)FRAMING I 0 M8 HEX RANGE 8° S-5-E CLAMP TYPICAL N BOLT R Y SPACING VARIES t.e — . (E) _ E SEAM — - ._ METAL ROOF `•5"---`__ _--Y -`^ '_ RACKING LEGEND _ in -- l`D / /" /•' \ .. . -', _.. -.... .ROOF RACKING Rem Z • f......._2/3"OF TOTAL SPAN MAX ...{..... ,1, ..'� _...._i ROUT RACKING RAIL SPIKEROOT `3 RAIL MANUFACTURER (E)FRAMING MEMBER RAIL SPLICE KIT STANCHIONXw SE UON WARAT""TK V n 1/3"OFTOTALSPANMAX-_.__..___ n HTRASH!NG �_lv MOrioNx OIIP Q •MDDVLLI sr+OWNMJXTXMriN EXAMPLE SEE"S•100/TABLE OF COMPONENTS"' - J _. __ •DE rAILS IN SECTION OR SIDENEW 6 O C 3 RAIL EXTENSION DETAIL SCALE:NTS 4 RAFTER HOLE AND CONSTRUCTION DETAIL SCALE:NTS >O 3 I- to u; NOTE:WHERE FRAMING IS VISIBLE FROM ATTIC&/OR UNDERSIDE OF ROOF, Ox „ L- w 0 0VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURAL a U w `o DECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. u m S Y yS Y 'D1 N oO LLI W Vf 9 + Z m Q 2 K a EXTENSION OF RAIL RIDGE SAG IN INCHES NOT TO EXCEED RIDGE . ° Zoo a 1/3 1 LENGTH IN FEET DIVIDED BY 20 a a RAIL OR STRUT CANT CONNECTIONS TO MEET , 1 MAX RIDGE BEAM NOTCHES DEEPER THAN 1/4" w o m NOT ALLOWED ALONG TOP OR f f a WEIGHT REQ.OF EQUIPMENT .. t '7-'-- 1/4 BOTTOM EDGE OF FRAMING 44 m '^ D er ROOF TOP -\' .. :4 •*�`-�`,'.. 14°MI LESgLL / Yt v m CONDUIT ILXBJ ' - 's :; (. M+y w O LEHAQorFR LYlN Signed 11/8/2022 m e 0 N DC I !yJNG SPgN u COMPONENT+ i 2"FROM SIDE 2"p, 7 F # 1c.i LL/ OF MODULE I 1 °1O J� X 'FRAMING SAG IN INCHES NOT TO EXCEED FRAMING LENGTH J VERIFY THAT NO [�l IN FEET DIVIDED BY 20 o rye{ DIAGONAL AND/OR VERTICAL y > 0 ATTIC/FRAMING STRUT MEMBERS L-HOLES ALLOWED ONLY IN MIDDLE THIRD ARE CUT OR NOTCHED OF FRAMING DEPTH,'R2,AND NO LARGER #09 F.1 PI THAN'R2/4 IN DIAMETER.MINIMUM :i •MODIRFSSIIOWN PORTRAIT INEXAMPLE SPACING BETWEEN HOLES AT'R2 (lip .•HAILING SHOWING IN VERTICAL IN EXAMPLE •SET OFTARS'T 21S200'TAME Of O YFNS'ONS ~'`'` PV MODULE#1 SPECIFICATIONS MICRO INVERTER#1 SPECIFICATIONS AC COMBINER(SOLAR LOAD CENTER) AC SUB-PANEL#1(IF APPL.) K„ MANUFACTURER REC Group MANUFACTURER Enphase MANUFACTURER Enphase Energy NEW OR EXISTING Z MODEL NUMBER REC400NP3 Black MODEL NUMBER IQ8PLU5-72-2-US MODEL NUMBER X-IQ-AM1-240-4 MAKE/MODEL O WEIGHT 4/ 1Ds '-..•"r'''''' ''''''A1120111230 WATT AC MTV'rocaATV..i MIA Y.rc 240 VOLTS TYPE OF PANEL ~ DIMENSIONS 74.8 x 40.9 x 1.2 L'x W i D'/nIICK WEIGHT 2.38 Ibs. RATED CURRENT 125 AMPS NUMBER OF POLES P 5 PEAK POWER(I STC(Pmax) 400 WATTS DC INPUT NUMBER OF POLES 2 P NEMA RATING ~ Voc(OPEN-CIRCUIT VOLTAGE) 45 VOLTS DC Max PV POWER a MODULE STC 290 WATTS NEMA RATING 3R BUSS BAR RATING AMPS 2 J Vino(MAX-POWER VOLTAGE) 37.6 VOLTS DC Max INPUT DC VOLTAGE 60 VOLTS DC MAIN BREAKER SIZE N/A AMPS SUB-PANEL MAIN BREAKER AMPS B. U Isc(SHORT-CIRCUIT CURRENT) 11.39 AMPS Max INPUT CURRENT 15.0 AMPS TOTAL INPUT CURRENT 20.57 AMPS MAIN SERVICE PANELP.O.C.BREAKER AMPS CC O 2 Imp(SHORT-CIRCUIT POWER) 10.64 AMPS MODULES PER MICRO INVERTER 1 CITY NUMBER OF BUNCH CIRCUITS 2 CIRCUITS SUM OF EXISTING CIRCUIT BREAKERS AMPS MFR.Voc TEMP COEFFICIENT -0.26 TL/K AC OUTPUT MAX ALLOWABLE SOLAR CURRENT AMPS w- Cf MAX SERIES FUSE RATING 25 AMPS NOMINAL VOLTAGE OUTPUT 240 VOLTS AC AC DISCONNECT#1(IF APPL.) PV BACKFEED BREAKER NI AMPS(Imax)W j LU TEMP.CORRECTED Voc 50.4 VOLTS DC MAX OVERCURRENT PROTECTION(OCDD) 20 AMPS MANUFACTURER Eaton PV BACKFEED BREAKER N2 AMPS(Imax)Ce N MAX.OUTPUT CURRENT 1.21 AMPS-MAX MODEL NUMBER DG222URB N QUANTITY 1 LAC DISCO.(S) AC SUB-PANEL#2(IF APPL.) N W N DISCONNECT DEVICE TYPE NON-FUSIBLE DISCONNECT NEW OR EXISTING <co r I 0 O CI RATED OPERATIONAL VOLTAGE 120/240 VOLTS MAKE/MODEL RATED CURRENT 60 AMPS TYPE OF PANEL OI NUMBER OF POLES 2 P NUMBER OF POLES P > I.I.I NEMA RATING 3R NEMA RATING U Ce FUSE RATING N/A AMPS BUSS BAR RATING AMPS TOTAL INPUT CURRENT 20.57 AMPS SUB-PANEL MAIN BREAKER AMPS MAIN SERVICE PANEL P.O.C.BREAKER AMPS AC DISCONNECT#2(IF APPL.) SUM OF EXISTING CIRCUIT BREAKERS AMPS MANUFACTURER MAX ALLOWABLE SOLAR CURRENT AMPS N MODEL NUMBER PV BACKFEED BREMER NI AMPS(Imax) Z QUANTITY LAC DISCO.(S) PV BACKFEED BREAKER 112 AMPS(Imax) 5 DISCONNECT DEVICE TYPE - d RATED OPERATIONAL VOLTAGE VOLTS MAIN SERVICE PANEL(IF APPL.) U Q N RATED CURRENT AMPS NEW OR EXISTING EXISTING 8 NUMBER OF POLES P ELECTRICAL SERVICE 120/240V Single Phase w c NEMA RATING BUSS BAR RATED CURRENT 125 AMPS L ID Q Q FUSE RATING AMPS MAIN BREAKER RATED CURRENT 100 AMPS C] . C TOTAL INPUT CURRENT AMPS SUM OF EXISTING CIRCUIT BREAKERS AMPS O C E C MAX ALLOWABLE SOLAR CURRENT 100% 25 AMPS = E O L MAX ALLOWABLESOLM CURRENT 120% 50 AMPS(Wax) CL t U _0 PV BACKFEED BREAKER NI AMPS(Imps( U 0 LL _ PV BACKFEED BREAKER N2 AMPS(Imax) Y ALT.ENERGY BACKFEED BREAKER(IF APPL.) AMPS(Imps) 0 U III Z 8 88D- LEi Z 0 O 0 < O Q Q O SCUD a O o.0 a . a .Noa m Q CO 1 1'N ke ai m o '-I a c a rn E `o • - W N J PV SYSTEM MAXIMUM VOLTAGE(MODULE VOCMAX) A DATA SOURCE I SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/EXPEDITED-PERMIT/MAP/ > NI STC MFR.PTEMP CORRECTED TEMPERATURE EXTREME MIN. TEMPERATURE CORRECTED COEFFICIENT FORMUUL TEMP. MODULE Va CORRECTED I TEMP.IT TEMPERATURE IVDC) OPEN CIRCUIT ASOP IT) (-0.N%/CI'100 COEFFICIENT VOLTAGE -20 - 25 = -45 * -0.26% = 0.12 + 1 1.12 * 45 = 50.4 WIRE AND CONDUCTOR NOTES WIRE COLOR CODING(2020)NEC SECTIONS 250.119&200.6 VT PV DC WIRING AC WIRING J 1. ANY CONDUCTOR LENGTH UNDER 50'DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS Q 2. BECAUSE WE ARE UNABLE TO DETERMINE THE EXACT PATH THE INSTALLER WILL RUN CONDUCTORS;WORST CASE SCENARIOS.ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMENT GROUND GREEN OR BARE,OR GREEN/YELLOW EQUIPMENT GROUND GREEN OR BARE,OR GREEN/YELLOW U DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORS THAT ARE IMPROPERLY SIZED. GROUNDED CONDUCTOR 3. WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED 1000 VOLTS ANY COLOR OTHER THAN GREEN OR WHITE/GRAY (NEUTRAL) WHITE OR GRAY 0 4. CEC/NEC 310.15(AN2)(AS APPLICABLE)WHERE TWO DIFFERENTAMPACITIES APPLY TO ADJACENT PORTIONS OF A CIRCUIT,THE HIGHER AMPACITY SHALL BE PERMITTED TO BE _ z USED BEYOND THE POINT OF TRANSITION,A DISTANCE EQUAL TO 10'-0"(3 METERS)OR 10%OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY,WHICHEVER IS LESS. ANY COLOR OTHER THAN GREEN OR WHITE/GRAY ALLOWED. WHEN LESS THAN I0'-0"OR 10%OF THE CIRCUIT LENGTH;THE LESSER AMPACITY MAY BE USED. TYPICALLY POSITIVE CONVENTION IS RED FOR GROUNDED SYSTEMS UNGROUNDED O CONDUCTORIS)HOT: CONVENTION IS LI BLACK cc U RED(L)AND BUCK(-)FOR UNGROUNDED SYSTEMS LL AND L2 CONVENTION IS L2 RED a 0 OC Z W 0 < DC WIRE AND CONDUIT SIZING CHART[SEE SHEET E-003 FOR THREE LINE DIAGRAM] 2 o CONDUCTOR CONDUIT FILL w D REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK R Ln SPECIFICATIONS DERATING CIRCUIT CIRCUIT (4 TAG qTY IN TEMP AMPACITY %K)AMPS) NOF MAX CONT. AMBIENT LILT. TEMP' OPERA„. AMPACITY NOF AMPAC TY CONDUITn ORIGIN DESTINATION PARALLEL RATING TRADE @30"C OR x COMBINED x CURRENT X OPERATION _ REQUIRED CIRCUIT TEMP. ABOVE ADDER PER TEMP. CORRECTION UNGRNO.CORRECTION COND. X TEMP. X FILL _ CORRECTED REQUIRED 5 CORRECTED Lu ry MATERML ('CI SRE PER 310.16 COANOMFNT PARALLEL 6908(ANT) 690.8(BM) AMPACITY ENVIRONMENT CC) ROOF(in) 330.15 (,C) 310.15 COND. 310.15 AMPACITY, DERATNG •DERATING - AMPACITY AMPACITY AMPACITY Q"- N 4MEPSI CIRCUITS _18112Nd IB11284) IB))3Na) 0$ CD DC1 PV MODULE INVERTER (1)CU 90 AWG 30 11.39 X 1 X 1.25 X 1.25 • 17.8 ROOFTOP 35 >7/8" 0 35 0.96 2 N/A 30 X 0.96 X 1.0 = 28.8 17.8 5 28.8 rl 1 - > LU W cc H Z 5 u Q 1'4 J O W o 2 Q 1 O - c I- IB u O m Ei 2 = t 0 10 . a to `o u00NL Y O W co C OC a to Q O O Q AC WIRE AND CONDUIT FILL DERATE CHART[SEE SHEET E-003 FOR THREE LINE DIAGRAM] z a a CONDUCTOR REQUIRED CONDUCTOR CONDUIT FILL o` N M CONDUCTOR TEMPERATURE DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK SPECIFICATIONS AMPACITY DERATING ar ND TAG CIRCUIT ORIGIN CIRCUIT MAX INV.OUTPUT TEMP. AMPACITY AMPACITY O y DESTINATION QTY IN TEMP TRADE AMPACffY CON„. CURRENT(AMPSI REQUIRED CIRCUIT AMBIENT ABOVE ADDER PER OPERA„. CORRECTION NOL CORRECTION COND. TEMP. CONDUIT CORRECTED REQUIRED CORRECTED .mH Q M, PARALLEL RATING @ 30 C OPERATION X TEMP. ABOVE UNGRND. % X FILL 5 W EO & SIZE OR AMPACITY ENVIRONMENT 310.15 TEMP.(Y) 310.15 310.15 AMPACITY DERATING AMPACITY AMPACITY AMPACITY % c MATERIAL 1 CI PER 310.16 690.8(B)II) COMPONENT ('CI ROOF(In) (BH2HC) IB1120) COND. (BI13NB) DERATING ry 2 (AMPS) ACI INVERTER IUNCTgN BOX = • a (1)CL 75 AWG 25 1.25 % 10.89 • 13.6 ROOFTOP 35 >]/8" 0 35 0.94 2 N/A 25 % 0.94 % 1.0 • 23.5 13.6 5 23.5 to N O AC2 JUNCTION BOX AC COMBINER (1)CU 75 AYVOG 35 1.25 X 10.89 = 13.6 ROOFTOP 35 >7/8" 0 35 0.94 4 .80 35 X 0.94 % .80 = 26.3 13.6 5 26.3 O- AC3 AC COMBINER AC DISCONNECT (1)CU 75 Z. 35 1.25 X 20.57 • 25.7 EXT WALL 35 N/A 0 35 0.94 3 1.0 35 X 0.94 % 1.0 = 32.9 25.7 5 32.9 AC4 AC DISCONNECT CIRCUIT BREAKER DISCONNECT (1)CU 75 MI//O G 35 1.25 X 20.57 - 25.7 EXT WALL 35 N/A 0 35 0.94 3 1.0 35 X 0.94 % 1.0 = 32.9 25.7 5 32.9 W ACS [milli BREAKER DISCONNECT EXITING SERVICE PANEL (1)CU 75 A86 65 •' 1.25 X 20.57 •• 25.7 EXT WALL 35 N/A 0 35 0.94 3 1.0 65 X 0.94 % 1.0 • 61.1 25.7 6 61.1 C 1 AC6 % _ % x = 5 N AC7 X - X % = 6 j AG X = X x = 5 ••f' 4. AC9 X _ X X = 5 10 ACID X = % X = 5 • BRANCH MODULE OTT ocPD EQUIPMENT TABLE LEGEND 4 A 1 2 9 8 20A 20A TAG OTT 1 17 PV MODULES COMPONENT ® DC Q EQUIPMENT 2 REC400NP381xk j Q 2 17 MICRO INVERTER Enphase IQBPLUS72-2-US (ICI r— W VAS 3 1 AC COMBINER BOO Enposse Energy%-IQ-AML-A R 'Y' AC CONDUCTOR TAG GN GROUND CONDUCTOR TAG (-91 I 4 1 JUNCTION BOX laEBox QM-JBX-RID1-B1 UA Q_ I Lhfi I SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS . I 5 0 NEW SOLAR LOAD CENTER LL I - ELECTRICAL NOTES s , �a 1 6 1 AC DISCONNECT AT GROUND LEVEL Eaton DG222URB LLI Z "'4. y. -— ---'—'I I MODULE NAMEPLATE 7 0 PROO/GEN METER *INTEGRATED MICRO INVERTERS(AC MODULES)MUST BE CERTIFIED d J I UL3742 AND ULI703 COMPLIANT.AS EITHER INDIVIDUAL EC LU 1 AI WOMB I I I RATING 400W BACK-FEED SOUR BREAKER: N/A 8 0 SUB PANEL COMPONENTS OR AC MODULE ASSEMBLY.THEY MUST ALSO BE LL La_ LL I A9 0 AC DISCONNECTIFUSIBLE) LABELED"UTILITY INTERACTIVE"CONFORMING TOIEEE1547 VI I— OC 1 1 10 1 CIRCUIT BREAKER DISCONNECT 70A BUS/MLO TESTING. Lal _ _ __ I I I *PV MODULES THAT HAVE INVERTERS ATTACHED WITHOUT AN AC w MaI— /.�i 11 1 EXISTING MAIN SERVICE PANEL 125A BUS/IODA MB MODULE EVALUATION BY A NRTL MAY VIOLATE THE ORIGINAL IL N I I 1 1 INVERTER NAMEPLATE LISTING OF THE PV MODULE AND VOID THE WARRANTY OF RATING 30OW1240V 12 1 EXISTINGUTRJTY METER 120/240V-DJD N I A I ' ' THE MODULE. N I 11 _. 13 0 BATTERY THE MODULE IS COMPATIBLE WITH MICRO INVERTER WO r r�` co 1 1 I I I 14 MANUFACTURER AND MODEL. 1-N M 1 *ARTICLE CEC/NEC 690 STILL APPLIES.THE INSTALLER I I I NOTE:EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER N/A USED WILL NEED TO CONSIDER REQUIREMENTS SUCH AS:DC GROUND C]O O I EMSMISISMI I I I I CONDUCTOR TABLE CONDUIT TABLE FAULT DETECTION AND INTERRUPT,DC CABLE MANAGEMENT.DC „"I,L O TELTAG QTY. LII TYPE GROUND SIZE TYPE DISCONNECTING MEANS AND DC GROUNDING AS WELL AS THE AC I Ic1Gc-1 I 1 I 1 I EQUIPMENT GROUNDING CONDUCTOR TO THE INVERTER. LL 1 1 1 1 1 DCl 2 N32 AWG PV WNe N6 AWG N/A Open Air *ALL OVERCURRE NT PROTECTION DEVICES IOCPDFI MUST BE RATED W AC1 3 N12 AWG TRUNK CBI N6 AWG N/A peen AF FOR 600 VOLTS ON THE DC/PV POWER SIDE OF THE INVERTER L1C*ALL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED FOR 1 STRING(Ll/L2 SHOWN)OF(9)MODULES AC2 5 110 AWG THWN-2 N8 AWG 3/4 inch EMT WET AND DAMP LOCATIONS WHEN APPLICABLE. 1 STRING(LI/2 SHOWN)OF(8)MODULES AC3 4 RIO AWG THWN-2 NB AWG 3/4 inch EMT INTERCONNECTION NOTES: I I I I e AC4 4 1110 AWG THWN-2 NB AWG 3/4 Inch EMT *705.12IB)(4)CIRCUIT BREAKERS MUST BE SUITABLE FOR BACKFEEDING.NEC INFORMATIONAL NOTE:FUSED DISCONNECTS, ACS 4 N6 AWG THWN-2 NB AWGDRUG EMTUNLESS OTHERWISE MARKED,ARE SUITABLE FOR BACKFEEDING. AC6 .690.131FII2)DEVICES MARKED WITH"LINE"AND"LOAD'SHALL NOT NAC7BE PERMITTED FOR BACKFEED OR REVERSE CURRENTZ*705.12(BI(5)CIRCUIT BREAKERS BACK FEED FROM UTTUTY 5 AC8 INTERACTIVE INVERTERS(ANTI-ISLANDING,UL 1741 CERTIFIED) C proairo AC9 *NO CENTER-FED MAIN BREAKER.PANEL CONFIGURED V LNLpp ACID PER NEC 705.12(A) O 1 1 I I NOTE:ALL LINE SIDE PV CIRCUIT CONNECTIONS INVOLVING TAPS AND OR TRANSFORMERS SHALL J INCORPORATE GROUNDING ELECTRODE CONDUCTORS IG N BONDING)IN ALL LOCATIONS THAT ARE Q NJ O i� _�� I�� 'INCLUDES GROUNDS CURRENT CARRYING CONDUCTORS LO Q Q SEPARATELY DERIVED SYSTEMS AS REQUIRED BY CODE D ORTHE AHI.GROUND BONDING c I 1 1 I JUNIPERSICONDUCTORSI.10 CONNECT ANY APPLICABLE SEPARATELY DERIVED SYSTEMS SHALL BE Q 3 C c I I I I FIELD VERIFIED BY QUALIFIED ELECTRICAL CONTRACTOR I— C 7 .36 I I I I NOTE:CONDUCTORS AC3,AC4&AC5 MAY BE THWN-2 OR SEE CABLE 0 > E w I I I I a L U O U co LL I I I I _ I I I ��M>I OO s w 1 Z I I 11 F�YY co . w a I I I I © I ti..- Lc Z 00 C a ....._............ Q O DD I I I I US RATINGr . i. I I --. Lr '- a vI I "---.......I I I I 1ZSA READILY ACCESSIBLE OPEN BLADE AC •H y - DD BUS I I I I i i SYSTEMAPPROACH TO RE IDENCE 60A 240VISCONNECT VISIBLE FROM I• I IRATINN GSRATING I N 's'' 1 I I I I LOCATED EXTERIOR ON WALL pp 125A v d a 1 1 1 1 I I NEAR METER NEMA 3R I •I I l A „t I m --- I I I 1 ITI fi M 19 I I I G I o COMPLIES WITH NEC 240.21 1 1 —•_ ,-+L� 1 1 1 1 20A livid e O[PO RATING 30A u 11III 1- w - ..�_III r ...i ,1 rel 1 13 --- — I� Li / L _ _ _ jJ > *,� • .0' EQUIPMENT GROUNDING I— D 1.METAL PV MODULE FRAMES NEED TO BE CONNECTED TO THE EGG 0 (EQUIPMENT GROUNDING CONDUCTOR). 1.1.WEEDS MAY BE USED IN LIEU OF MODULE GROUND CLAMPS / OR LUGS,WITH APPROVAL OF Nil AND RACKING MFG.WEEDS ...I ARE ONE TIME USE ONLY.SEE"we-Ilc.con,"FOR RACKING SPECIFIC WEED,INSTALL INSTRUCTIONS,AND UL 2703 CERT. —I1.2.FOR"LAY IN"LUG MODULE GROUNDING;CORRECT V HARDWARE OF PROPER METAL MATERIAL TO AVOID 1 CORROSION MUST BE USED.TYPICALLY DIRECT BURIAL RATED, — TINNED,OR STAINLESS STEEL.GROUNDING LUGS MUST BE Fe CC ATTACHED AT MARKED LOCATION ON EACH MODULE. ILl U. I- 2.THE EGC(EQUIPMENT GROUNDING CONDUCTOR)IS USED TO VI 1- U BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSED ,m w METAL PARTS THAT MIGHT COME INTO CONTACT WITH ul —ICURRENT-CARRYING CONDUCTORS,INCLUDING THE FOLLOWING: K H LLI 2.1.PV MODULES FRAMES,ARRAY MOUNTING RACKING;THE N METAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS, DISCONNECTS,METERS,JUNCTION BOXES AND COMBINER I-N BOXES;AND METAL CONDUIT HOLDING CIRCUITS,250 VOLTS O 40 Q TO GROUND PER NEC 250.97 Q 3.THE GEC(GROUNDING ELECTRODE CONDUCTOR)IS THE .4 Y-1 CONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THE SYSTEM GC,TO THE EGC,OR TO BOTH. > 1.1.1 IV 4.THE GE(GROUNDING ELECTRODE)IS A CONDUCTING OBJECT, DE OFTEN A ROD,RING,OR PLATE ESTABUSHING A DIRECT CONNECTION TO EARTH.THE AC SYSTEM GROUND IS EXISTING, USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PLACE AND MUST NOT BE DUPLICATED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. ELECTRICAL SYMBOL LEGEND z Z ® AUTO TRANSFORMER ® JUNCTION BOX 0- ® SOLAR LOAD CENTER ® AC DISCONNECT IACCI AC COMBINER ® SERVKE PANEL V N i / BAIT BATTERY ® PERFORMANCE METER Q p L ® SUB-PANEL EAL CL CRITICA J N �/ [$]CIRCUIT BREAKER DISCONNECT LCLPT CRITICAL LOADS PANEL a, Ifs EMERGENCY BATTERY DISCONNECT ®TRANSFORMER Q ^ C /� MI EMERGENCY RSD SWITCH ®AUTO TRANSFER SWITCH F IB a® SMART TRANSFER Q SWITCH N E C SECTION SECTION RPV ARRAY TAG IOM TESLA GATEWAY = t O 1 MODULE GROUP ® TESLA POWERWALL - U 0 .4 1-7 W ILL NA SS E __g w in' UI , EXISTING EQUIPMENT IO PV AC DISCONNECT LOCATED ON ACCEESSIBLEIBLE EXTERIOR / WALL WITH EXTERNAL HANDLE VISIBLE,LOCKABLE& tii Q Lk' Lk' Q c d / LABELED WITHIN 10 FEET OF THE METER. Z p Q 4 I] 0 4 / a 71 a co ^ ¢ co i� N i2I^ // / N K' y ti U O �/ / 0 /// w 12 'e a ......1Te QIN 17 REC400NP3 Black MODULES, QTY 17 Enphase IQ8PLUS-72-2-US MICRO INVERTER NORTH SCALE:1/B"=1'O"@ SHEET SIZE A3 1 CONDUIT RACEWAY,1-BOX,AND PULL BOXES I. VETr 2 DC DISCONNECTS 1J4•ni ff 3 INVERTERIS) /4"'1. SHEET NOTES . .. _.. -- roof ABBREVIATIONS' OC WARNING PHOTOVOLTAIC AWARNING AWARNING NnIDNnlEurwA(a (NE() w/TLNaT(XIAI rpn..wL CODE(MC) POWER SOURCE ELtLIHICALSHOLK HAZARD THE DIICGNNL'CTiONOFTHE NT.RNAIRNIATMDIDE„Ili41T.N1.N(Mg TERMINALS ON THE LINE AND LOAD GROUNDED CONDUCTOR(S)MAY NTPRNATICNM r RF EOM DfEI 'JNDERWRFORS IABOA fORY DA) H d SIDES MAY BE ENGERGIZED IN THE RESULT IN OVERVOLTAGE ON THE 3 COMN!NA{wy�ryA( DSMAYNFUSEDINP[ACEOI MUL1WLE re 1. P!A(:f(XiCONDUIT ANOJCIRRACE WAYS EVERT 1(Y I68'L 12" OPEN POSITION EQUIPMENT PIACARDSEORDIE SAME I/EY!CE.AIL.INFORMATION FROMTIr to CC j FROM KNITS,I?ABOVE AND BELOW PENE TRAIIONS. MIA TIME PLACARDS MUST NE PgfSFNI. 6 Q 1. fU(ED(N ITC DEMONIC:1(SI AND UKANY L. MINIMLtM OF'1l/?'v ID LT2 2. caw REERDINCF'IEEE(AD 11101))) EE0'IPMtNIIHA)STAYS ENERGIZED IN THE(XF J 2.BIA(K IEREN4 WI1H YELLOW BAO(CAtS WITH MAY BE USEDIN 0 0 3, MINIMUM PLACE CX THE STANDARD WI UTE LETTERS WITH IND ,.. Z Of 51J8" 5324' POSITION FR(X,1 THE YY SUABLY. 2 IOW{:3J8' Q BACKGROUND WITH AHIAPPRUVAL. V�1 F- A, f'ON/:3/8"ANO.B WIDTH FACTOR. 2 CINXREFERENCE'1111.F.941.1'y)l 3 WARNING LABEL IS WHITE AND ORANGE 3 AUINIERIORANDEXIERKXROECONINJIT,ENCLOSURES, ul>.. F- 0 REHECTAq.WHITE IFTTERS ON A RED BACKGROUND. 3. MINIMUM Of31/2"X10' RACEWAYS,CABLE ASSEMBLIES,PIN(IION BOXES,COMBINER m t/1 A fUMl:3/8" BOXES AND DISCONNECIS ARE MARKED.(NEC 690.31161,NEC IX''Lr, CA0.13A690.511 S. WARMNGLABkt.I'i :. I N - ._. j_. ,.._._,_.......,.._....,.__.._.....___._____�_�...,�.......-._._... .__., '1 ITT MARK.NGt ON TItEIfMIDIBTS,RACEWAYS ANf1CARlF N • 4 NON-LOAD BREAK DC COMBINER/I-BOX I S I DC COMBINER BOX VALE: • trA_ ASSEMBLIES ARE EVERY 1DrkET,wTMN ONE TOOT(X ALL �-(Q( s V7"-1'-0" ! 7R-t'ff ;6 SWITCHBOARDS I I/r I.0, TURNS OR BENDS AND WU HIN ONE TOOT ABOVE AND<LOW Q m r-I ALL TRA/IONS Ur RU0E/Ca BRIG ASSEMBLIES,WALLS AND Cl 0 0 DONOT OPEN UNDER LOAD DC COMBINER BOX AWAH HAZARDNEC OR MEMBRANE RUIN!NG MAIL RIMS N ROOIAREMS NO1 > CI- • • APPROPRIATE PPE REQUIRED COVERLET IXniu Noi Pv(I4u lsienlIBEl ASSOCIATED UEpMkHI,THE • 1. COL REFERENCE.NEC 690.1311:1 I FAILURE TO COMPLY CAN RESULT IN B REQUIRED LABELS SHALL BE PERMANENI AND SUN ABLE FOR } USE ON NON ROAD RRIAK RATED VIVO„ISIITI)k. • THE Eliza RESISTANT MATERIALS USED FOX MARKING MUST BE 3 MINIMUM OF 1•ar• COMBINER# • • DEATH OR INJURY WEARIER HFRRgTM(,[II LISTING U1 MA/IRINfiSLISS WTI REFER TO NFPA 70E 111411RPD.SEE III 14REIIN1,SYSTEM 9i8(UI9H) 4. FOM:3/4"AND.B WIDTH FACTOR • S. WHITE LEITERS ON A RED BACKGROUND. 1. USE.PLACARD'CCMIRRIER III"WHEN MORE THAN 7,MARKING((MIEN]AND fLXRMAI: DC COMBINER IS USED.NUMBER ACCORDING TO 1. VFR.FYWRCII PLACARD IS RE IX)!RE 0 WITH AM. • 7.1, NWT:OR SIMILAR FOIL,NON-BOLD. Z • THREE IMF DIAGRAM ANDCATEUI.A11.'Xi<_ 2. M:NI.UM UL l4' 7.7. MINIMUM 378"LEITER HEIGHT FOR HEADERS. 2. MNMfiJM OF xd' I. SON/3/8"AND.B WUTN LAC/GP 7.3. MINIMUM VIA"LETTER HENiNI FUR DATA DO NOT DISCONNECT UNDER LOAD ;, FONi;3JB AND fiTO.8 WWII(AEI R 74. CONTRASTING BACKGROUND AND LETTERING. O 4. WARNING UBEI IS YlY{E AND ORM1N(iE 4. WI4I IE LE T.ERS UN hRED 7.5. ALL CAI`!TgLIET"FENS 1..7 • BACKGROUND.RCIVNU. ! 5. [MIA COLLECTED T ROM ASBULNFO 7.6. CONTRASTING SPACE BETWEEN ROWS Of TEXT D Q N .._ �.- } T/ CAME NS.CNS OE PLACARDS ARE MMRUXIMAIE,M BE PR.OR TO TO,BY OTHERS. I SCM.C._ __ < ......_.. _ __.._„ ._._._ _.__......___ ---, SCALE' REDIAI,AND/OR MC-TEASED TO UI.APPROVED MAY J 7� MAIN SERVICE PANEL 1/4".1 * 8 AC AND DC DISCONNECTS 9 1$OX,DC COMBINER,AND DC DISCONNECT a, lJa'-S O" { _ �4"=1-0" MANLRALIUMIT PRCIUull -J T Q I. LOCATE NO MORE THAN 1 ra(ROM THE SERVX'E DISCO(NT ENGINEERING STAMP(if appl.) Q = c - a ME.ANSTOwIBn(THI Ev Y Mara L'NMr*,DAIS) ACDISCONNECT#I AWARNING ......._ ___ __ _.._. ....... r _ m d INDICATEsHAI( n+r + , '.,"„ ELECTRICAL SHOCK HAZARD c (' SI{(1TOL;WN TIll 0 = E N TERMINALS ON THE LINE AND LOAD SOLAR PV SYSTEM EQUIPPED DCDISCONNECT#i ; a t T. LI m WITH RAPID SHUTDOWN JSE PIACMD[A(.RTC1Ot ONNE/'FIt"WNENMOOR SIDES MAY BE ENGERGIZED IN THE ..aTHAN ONE[MYONKECT ISIISW NUMBER ACCORDING TO OPEN POSITION o WI ((R ,• I HREE UNELIIAGRAM AND CALCULATIONS. • O El • I DC VOLTAGE IS ALWAYS PRESENT • a o o SWITCH rn� PHOTOVOLTAIC PHOTOVOLTAIC ! WHEN SOLAR MODULES ARE ZCI CI I 'ol P ` 2 TO ) EXPOSED TO SUNLIGHT • SHUT0(7 PV SYSTEM DC DISCONNECT AC DISCONNECT I o N v AND FRIDGE I I 1. ()HEY FOR UNGROUNDED SYSTEMS. a.. .9.. m • SH m DCI(H I)IAV 3. PLACE CM ALL AC AkV CX;pSCCN3NECTS 2. PLACYD(TNALENCtv')SIIRES Wrth1 UNGROUNDED EXPOSED O '�H p • ` (1 OR DEVICES WHICH ARE ENERGIZED AND MAT BE EXPOSED m • 2. CODE REFERENCE:RU..690.13 B - m Q umt DURING SERVICE. .:( > 2. CODE REFERENCE'NEC 690.56(11(1)II) 3. MINIMUM OFI°.x IC 1J7." 1 MINIMUM OF 3"a101/2' N t: 4J .�.( 4 FONT'316" V c 3. TITRE'MIN.3/8"BUCK CHARAIIERS ON YEUUW 4 FONT:3JR'CKGRWMO,REMAINING CNARACICR5 MIN 3/16" 5. tYNHELET'TERS VNAP.ED RA(RI,Il)LAND. • IIM IN BLACK ON WHITE RACKGROUNO_ S. WARNING LABEL IS WHITE AND()RANGEm• SCARE' SCALE: LL 101 INVERTER(S) 1Jr-ro" 111 RAPID SHLrTDowNSWITCH 1J4=r.m • 1 ARAPID SHUTDOWN SWR EH SHALL HAVE A INTEL IDEATED �(� INVERTER # 1 ON NC MORE T1IAN 1.M II FT)FROM THE 5WITE11 THAT E,f,1 INC.LILNS 1HE 1)11(.WIN: q F) RAPID SHUTDOWN SWITCH • t^ 1. USE„ACARD INVERTER V WHEN MORE TI{AN I FOR SOLAR PV SYSTEM s. -->I INVERTER 51)5ED Num&ft AtCONLANG fO THREE �_ y UNE DW,HAM AKt/CAICUtAHIXLS. ( rt") 2. MN!MINN.(I't"an" 2. lNE LAPEL4111SHALL 111 NEI10111)'E WITH ALL LETTERS CAP)TAgEU O i • > AND IIAVIN(3AMININR)M HE nil Of 9.5 MM13'lS IN.), ! -+S,-g i. FONT:3/8' IN WHITE ON RUT BAC XGROCIND. I,2 g 4 WHILE LEVIERS ONA RED BACKGROUND. r!.`I OTY 17 REC400NP3 Black MODULES. QTY 17 Enphase IQBPLUS-72-2-US MICRO INVERTEI c+. l_f_ AC COMBINER 1 suo: 1/2"3 I'CT 2 I AC DISCONNECT,AC SUB-PANEL %ME:it, ,. ) 3 UTILITY METER,SERVICE PANEL,SUB-PANEL SCALE: 1/4"..1're 1 SHEET NOTES • .•• tr) i . AC COMBINER DISCICNNEC I Al EMS'ARBREVATIONS, 0 PV SYSTEM AC DISCONNECT rnArfrovot.INC SYSTEM WARNING , I NA HONAL ELECI WM CODE NEC) 1 ITNE.RNATIE/NA;ROWING(013C BBC) 6 i AC COMBINER BOX IBWED AC(NOMA CURRENT 20S) AMPS AC DISCONNECT (.1•1!.±2.9'....•!^.9.!!T•ITI!:9.Y.9.1.-.P.!9f,....12.1.5.....Y.9!:. . V."",==.% • "'-'''''''''AGE ots 30(13 DUAL POWER SOURCES 1.Ni 10 ACNINITCORPOO NE) MIPS! ; IN II RNA TIONAL RESIDENTIAL CODE(IRC) I INTERNATIONAL FIRE CODE IIF(") 5 I INA..ONPAIN6V0TA0C ”.vousi 1 UNDERwRnRs tmoRmoav mu !7. AC COMBINER EVIM3ONECT 62 , 1.COMBINAT ION PLACARDS MAY BE USED IN PLACE OF MARINE Ir U _ COMBI\IER # 1 PV SYSTEM AC DISCONNECT IATED AC OUTPUT COMENT 205? AMPS AC DISCONNECT oun.OW CNINTAINS TWO SOURC1.S OE POWER TITILITY SOAR PV PLACARDS FOR IN SAME DEVICE-AU INFORMATION FROM ; IN MULTIPLE PLACARDS MUST BE PRESENT. 0. 1.1 1 -1:ACOVINCI CIANN" av ANN 0 .1 I NORMAL OPERATING VOLTAGE ?Al VOL IS i .„cu.., until Y SERVICE DISCONNECT LOCA-I ED ,;,2 1 7.EN AI F LETTERS WITH VEDOW BAC.10.3RMIND MAYBE trim IN ,....,.. BELOW.SOLAR PVSYSTEIL DISCONNECT ; RIME OF DR STANDARD NIRO LETTERS WITH Rf I) VI 3.... Z I AC COMBINE BA OISCONNECI LOCATED NESAMI WAL L.ClE BDICE/NO ; CKGROU NAM ND AH N..I APPROV >I' I R) P3 ;.1S • I ALL INTERIOR AND EXTERIOR DC CONDUIr,ENCLOSURES, ---.03 0 1 PV SYSTEM AC DISCONNECT PNETRIVCA.TAK:SYSTEM ; RACEWAYS,(ABLE ASSIMM VS JUNCTION BOXES,(.OMBINER • RATED AC OUTPUT CURRENT AMPS AC DISCONNECT : BOX(5 AM)DISCONNECTS ARC MARKED.(NEC 690.31161. VI : EILAUJIND CONTANS-IWO I TEPEANNEPLA CMAANT SOURCES Or POWER: ; 1 MC 693.531 , I UTA ITV,SMAR EN N unolY SERVICE DISCONNECT 1N•...) I 4 R ECHJIRED 1.AWNS MINI RE PERMANF.NT AND SUITABI E.FOR of 2 I • AC SUR•PANEL At LOCATED BELOW.SOLAR I'V I ; DIE ENVIRONMENT MATERIALS USED FOR MARKING MUST BE F-')...... (NJ 1 SYSTEM OISCONIECT(CRATED 1 1 WEAVER RESIST ANT.IA STANDARD IS RECOMMENDED TO .1. 0 C) PV SYSTEM AC DISCONNECT PNOTONOUTAle SYSTEM r.447,s.m4/WAIL OF MIR DINT ] ; DETERMINE WEATHER RA PNG.IA EISEN;OF MARKINGS IS --.. 0 RATED AC OUT PU1 WAREN( ARV'S AC DISCONNECT i NOT MOORED SEE III'ARCING SYSTEM 969(IA 969) '-. ... 0 1, - RAE0 At>HOB CONN' AC NORMAL OPERATING VENTAGE VOL ES „..,,....„..,.,,„,....,,,„..,• ,,,. „..„,'.7. S.MARKING CON!ENT AND 1-(*MAT.•"-":"'"'-'s- ''''''."*"..'"I-, .".•'. 1.0111N MARI)PEACE('AT MAIN UNION SOLACE DISCONNECT/BREAXER AND PV SYSTEM ; • •' SUPPLY BREAKER Al POINT CV INTERCONNEC TION.1.2 A P31 MACARDOI ; ;1 ARIAI 01 SIMEAR FONT,NON ROt D . : AC 928-PANEL A2 RE N(sEtrn WITH K1 Pt ACARD WHEN LITWIN SEMITE/T.AND PV SYSTEM DISCONNECT ATIE I 5 2 MNIMUM 3/9.LEI OR HEIGH I t OR HEADE RS. Cr • PV SYSTEM AC DISCONNECT RA l'EL)AC OLITIVI CURREN1 1. AMPS Pico:IOWA.INC SYSTEM A TA VOTES 2 I LE AC DISCONNECT NOI:LO VALUES MC ATCD NLX1:I()EAST MATCH EQUCH(RICER MAP PLACARD REQUIRED AS SPECIFIED. 2. UIPMENT CACl/MOONS.ORMA'.OPERATING VOLGE ''' ''''' ' '' ''''.; VALVES WM MAC C H LOAD CLEV E R OR SONPANEL VALUES II II4ST L L,AFTER 3c)400AL cm.iFix3m)VOL IA> VI,3_13, ; S.I. MINIMUM 1/16.LE VIII HENNA TOR DAM ; 5.4. COM-RASING BACKGROUND AND LET FE RING AO N 1 66 AU CAPIrAt.LETT!RS. • •• MAC STIRS.WA'CONNECTION ICI SERVICE PANE I COWS/FROM INVE RTC RS;SFr 1 5 6. CONTRASTNG SPACE BETWEEN ROWS OF TEXT .••' SHEET"E.001/STRING INVER TERF111 SPECIFKATIONS'. ; 5 7. DIMENSIONS OF PIACARDS ARE APPROXIMATE.MAY BE .• , )1 1.INVERTERS ARE PARANA",CONNECTIONS . REDUCEn AM)/OR INCREASED Toll!APPROVED ' , .• 1 I.PIA(ARO PLACED ON EACIISTRAIR SYSTEM DISCONNECTING COMPONENT. .•• MANUFAC IVREA)PRODUC T USE PLACARD'COMBINER.I.'WHEN MORE CRANIA(CCHIABINFR ISUSE LE NUMBER 2.1)."RATED AC OIONTT CURRENT'WA I BE DIE SUM(A INF INVCRAERS •. • Z . ACCORDING 10 THREE NM DIAGRAM AND I AITIRATIONS. 2.VAI IlE S MOST MATCH EQUIPMENT CMCIRATIONS. IT'"AT NORMAL OPERATING WITACif.WRI.Bf DIE NAME.NATE RATING OF THE I 6.ANSI 2529 4 PRIVILY SAFETY SIGNS AND IA/ACE:THIS . a. MINIMUM OF 1.1 4" SEE SHEET"E.001/AC DISCONNE CI B' INS/TITER INFORMATIONAL NIECE AND I-IS RECU IRE MENA 5 FOR PlACNLIS 1 COLE REFERENCE.NEC 61()54 1 cm*REURENCF:roc,.,.441 54,NEC 705.1.7(RI)TI I MAY BE USED WIDI PRIOR APPROVAL 01 THEM.MOST a.. 3. FONT 3/6"AND.2310.6 WIDTH FACTOR MINIMUM. 1 NYMAN DIFFERENCES IS(NOR OF PANAMA AND USE(A 4.MINIMUM OF 1112'x S I/2"II NI,1 5t4".6 1.12-I BO T) A.MINIMUM Of r y6 la"11(1),VARIES III2&ELI1 1 HAND WRITTEN VALUES WITII INDUSTRIA'MARKERS ON 0 4. WHITE I[TITAN oN A RED RAEXGROUND. TN l' 6 PLACARDS MAY BE COMBINE()TOGETHER.II."AC COMBINER BOX NI'.MINIM,,M 5.fON-1,3/6"HEADER.3/16'LIAM S.FONT;VB.HEADER 2/16'DATA 1.15.•1/4"IIT2&.31 : STANDARD PLACARDS WHERE THE VAL IIE MAY CHANEL AT A .,t- I RFT UNE WE.I.E,ADDING MODULES Al A FutuRE WI E,OR I- 8 1 REQUIREMENTS LISFELI ABOVE 6.WHITE OTTERS ON A RED RACKGROIND. 6.WRAF LETIERS ON A REV BACKGROUND I SEAN DARD PLACARD MANUFACTURER INSTALLED ON --I eN 1 OE(MCAT I OMPONENT.A.111 APPROVAL SECTORED.NEE 0 GT -M I .1' .1 § 1 4 MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER Ilf NOT%ME MAHON) ii.,).iSCALE:, SERVICE ;. , 5 I MAP PLACARD:MAIN PANEL AND PV INVERTER 11,No r SAW LOU CAON) i iir.,v NEETE 11 1 FOR MERVIN/AI IR ACARDS) >.,. 1 -3 . I .• I- 7..I.! ca 1 • 0 % E t' 1 .• .• ' PLACARD PLACED AT ELECTRICAl.SERVICE AND AT THE IN 1. PI SCAM PLACED AT ELECTRICAL SERVICE AND AT CAUT I °N INVERTER AM)Pht DISCONNECTS IF NCI AT DEE SAME LOCATION. • THE PV INVERTER AND PV DISCONNECTS IF NOT AT ; 0_ 2 L.) so 1• MAP PLACARD PROVIDES.A DIRECTORY OF THE SERVICE CA UT I ON THE SAME ICKA HON. , 3 u es IN LT_ ; SCONNECING.I MEP/451ND PHOTOVOLTAIC:SYSTEM • 2. MAP FEACARD PROVIDES A DIRECTORY OF THE _V• DIgEINNEINON MEANS. SERVICE DISCONNECTING MEANS AND .• POWER TO THIS BUILDING IS SUPPLIED i 3. 1./or REFERENCE:NEC 690.561ABBL 7/SIR . PHOTOVOLTAIC SYSTEM LASCONNEC DON MEANS ; u) tit I • 0 L.O.T. 02 Z I FROM THE FOLLOWING SOURCES WITH i 4. WHITE LETTERS ON A BED BAcKENOUNE). P POWER TO THIS BUILDING IS SUPPLIED . 3. COVE REFERENCE:NEC 690.56(ARB),70S 10 I •• 00 a = e c o.I • a ,• , Z 0 0 4(I 0 0 I DISCONNECTS LOCATED AS SHOWN: I S. mimo mm oF 2 3/4.,,so i . FROM THE FOLLOWING SOURCES WITH 4. WHITE LETTE RS ON A RED BAC KGRO ma . LC) : 6. FONT 3/4.'CAUTION..114""WARNING.,3/16'HEADER, •. DISCONNECTS LOCATED AS SHOWN: 5. MINIMEM OF 6 1 It < <6 1/2" • • 1 . 1/E"DATA AND NOTES 6. FONT:lir'CAUPON..I/4"HEADER,1/R.DATA ] . •1 SOLAR ARRAY • • 7. PLACARD WILL BE PLACED ADJACENT TOME MAIN SERVICE . AND NCHES 6. fil Z. .•• •..• mu ON ROOE TOP 111111 . • • i DISCONNECT fr/A LIXATION CLEARLY WEIRE FROM WHERE THE DISCONNECT IS OPERAND.GEC 605.11.1.1 A NV. R331.231 • Mai SOAR ARRAY ie. ON ROOF TOP 7..PlACNA4IRDZilt,t,,,,,BE PLNACNETTINDIAACE,,NIT,T0.41IE CLEARLY VISIBLE f ROM WHERE TILE LIISCONNECT IS I OPERATED.ICFC 6115 11 1..3 A CRC R111 2.31 < 121 •••• 03 A : a ; ;I 11 .^ , .^., el eli :11 .•Pug' I I ••az 1 2 (MM.METER .• : : : • . III ... UTILITY METER : •• ••. • • ... = a.. .• ••, : • , • i • : • ••. RESPONSIBILITY NOTES . , ,.....,,DISCONNECT .•• .• 1 AC : . .• • ..• /All 4 1i .....,CESCONNECT . ;....- !1. PRIME CONTRACTOR/PERM',APPLICANT SIGNER 111/41111 4 , IS RESENHISIN f FOR THE DESIGN ANT) ; SPECIFICATIONS OF THE PlICROVOTAIC SYSTEM AC COMO KEA SERVICE PANEL 4, .••III 331:AKER.(31:ONNIC" : AC COMBINER SERVICE PANEL ill ; INSTALLATION.PRIME CON I RAC TOR/PERMIT a. W , 1. i APPLICANT SIGNER WIN Or M'SPONSWITE FOR o 1 C CIRCU/1 BREAKER DISCONNECT 1 (011 NECTIO Of EXISTINGis ON/ITT INFORMATION ' _I d .•• , . , 1 RE(JUIREMENIS 10 DESIGN,SPECIFY,AND INS MU. VI WARNING : : .•• :• . . • . • • , THE EXTERIOR MOINNI)PORT ION OF III > _I "1 . PtIONIVOITA/C.SYSTEM DE TAILED IN THIS !-M ELECTRIC SHOCK HAZARD.L'Il No;D.,,,,,T EN,,,,,ALs 1 MN OMEN( Ts < I TER),11NALS ON LION DIE LINE ANL,ICAO SIDES I • 2. ADVANCED SOAR SOA LIM ISNS.INC RESPONSIBI F. > >IA i•MAY BE ENERGIZE'S/1N THE OPEN INISITRIN 1 ' . ; FOR APPLYING SOPINIED INFORMATX)N INTO A SET(V PEWIT DRAWINGS ANY CHANGES TO • 1 DRAWINGS ARE SUBJECT 10 CON-1RM., CONN(IONS NINON NE(DEN(AND '..,,1t;411t. • I ADVANCED SOAR SOLUTIONS,INC.IN '•.^.‘:'', 010 1 ACCORDANCE WIT 14 PIE REOUNEMENT 5 OF OR I All - ----- „--„- -. ........ „ .- • PV MODULE CUT SHEET V) w w REC N-PEAK 3 BLACK SERIES to REC , v) F— SOLAR'S MOST TRUSTED Otto REC PRODUCT SPECIFICATIONS sm./as MOST TRUSTED 2 0.....1 • ._ o ca_ 'i iS'-)::..!li•';':;i::AgigiPlr,,,4,:il•,:'-:t.:,•,!!:i21:;...:1:::i.iIiiiii:iiii;:: :al ,, „ -, ll-1,,- —. , VI Cell 13Jhalf cot mortoc-Si o-typecalls toe. ,a 2 6strIngsof 22cells ln series —i 0, sla 7 CC U./ cals, REC N-PEAK 3 BLACK Backsheet< 1101yresistant . rs, <5( I—N 5EFRIE5 • ...... Ainclionbok 3 par I.3 bypassdlodes,dead-free • In613rated.,saccordente net51FC57790 8 s ccl ,taah5 MC4 PV-K8T l/NST4(a pan') . . PREMIUM FULL BLACK MONO Cable< ,2 AVIS(4rn(0.11Nwire.4/2(4/2 le :•S„. ''<.<- --K• H - , N-TYPE SOLAR PANELS 7,18-409a12m09 7sp 01 __ WogI-t . 47C s, , , , , • , ELECTRICAL DATA :< :":" ' ,R.;(„<<: Product Code'REG,x a NP3Btack . iq !.,TT:.•,..;...!..„ ,;.....,.::.-:..:*3,:,-,,W,i.MS v) Ell . 1 • 1E(.51215 2016,IEC 51/30 2016M 61730 1E(..52804 P1D all z ., i IEC 61701 Salt MIsI Nominal Rower Volt age•V.,,l,/) 36 8 37 5 IEC 62716 0 ' (_a Nornatal Pune/Copan.-1,,,.(A) 10 SO 10 b. UL 61730 Sox'TPeCiass 2 < ID , I— 0 MORON-TYPE:THE NOUGHT INDUCED IEL 62782 Dynan:::Mechanic O4 .-I MOST EFFICIENT C.SI DEGRADATION ' OaertCrcuitVoltage-Y (X) 44 8 45 0 —1 0 TECHNOLOGY IEC6121S2.2016 Hadsone(I 37 X L d in1 0 W 9wmCi.rtit M men,.1,(A) 11.31 p 39 1E0 4001,150 9001 IEC 45001 IEC629.0 > .1' •?t. IC anel Eliciency(%) 19 8 20 3 a' eO i295 102 b..—,(7. 0 (% E I ,Illi . , . . ,,owc.00pm-P„,(wpi NalninalPewer Vol<age-v.„,(V) In l Powe C (I (A) 56 8 9 r urren ,..,, 'i Opp,nrcsit%oh Irt.V....(V) 34 a 8. 41 9 35 2 5 4s I , ....,... ...... a._<.........AVO NsIolperatilg Ternperahre 443C OM I No omin MOd -' u co _ Z w TemperaIe coefi,lent vr.,„: -0 34 X.t.0 g.ti ln SUPERSTRONG FLEXIBLE Sho,ICirctilCutrent-1 (A) 9.13 9 20 0 u.I FRAME UP TO 7000 PA INSTALLATION if fempei at um coeMcion1 of V„: -0 26%r C 0 5 u.1 u..1 Z SNOW LOAD OPTIONS o- , 0.0,7V C vi < o 0 a Z o 0 , a a 'li • Oprnanionaltemperatpre 40....195,- S Mrorssyseccoolngo IOW<, Installed by anREC tandird RECProTlust CemfiedSclar Prof esmenal N° Y''' Y'' 0anolsper pallet 3 3 < 1 ? 1 ',9 g • ,, _ Tr Pandsner 40 ft GP/h,ghcabeconta'ner 792124 palle<sl 13 TRD "'"'""t1"d("" .'et*""V''-ftl. Syst ern 54e Al .251,W 25-5OOkW P"'"'"""'''' FEATURING REC S PIFACIAL CELLS CAN M PIONEERING PRODUCE ENERGY FROM , ,,,io.,I,,,,.). 4000,3(93 5 anIsci f(/ Prodps<Vial<AP,lin sl 20 25 25 TWIN DESIGN BOTH SIDES 5 71 May Sel WS fuse WOW 25 A Power Wa,ran1y(yr gsI 25 25 25 . Ma,e,<ersecurrent 25 A Labor Wart at ly(yr s) 0 25 1p Typ.sal low In Alamo polo-none of Neauln at 5 EC. 'E. t:Ael F 98% 98% 98% 1 .1 .._........_ '''''''•''t"''''I I V'" Annual Degradation 025% 025% 0 25% i j,----- Power M Year 25 92% 929' 92% 4 0 0 Available from: g .1 Inadimce(01/,,/ ...1 i ii , Z IA W WP xN, ' POWER -,:,:-.:E.,:.:..- > Foundrd PI 1996.RFC Gre(pion ntnrnsbonal pinnnenne solar ene<gy rornpanydndttated tc.mr-m/o,F.cormimem roth Oran.afforrIMIesola,posve,As C Solos'Most(ousted REC is convenedv ht It qualay Insovatiors and a low cal bon loatpi int PI the solar<natraals old sal<panels....marmf ao te RC es '.. E Headquarimed m Norway with ooemtional headqua,ter:la Singapore,REC also has reg,onat hubs P11.1o,IM1 America Europe.and Asin-Pacinc INVERTER CUT SHEET N I— w '— ENPHASE t=1 = I08 Series Microinverters to F 1- IekUr Data loci 101-6C-2.1.9 .2ar.09 72-2-1s 1789 s2-:-u9 I01a-7E-2.,5 irae.:40-12-:•ui [pax-:Dr-72 2, 2 co Cunrruunly usW rood.:pal,ttgs' w 235-35C 235-440 260-460 295-500 320-540. 295 500• w U D. cr Module compatibility 60-ce8/120 halt-cell 60-cell/120 half-cell and 72-cell/144 half-call WO a 4. LIPPT voltage range ,, 27-37 29-45 33-45 38-45 38-45 38-45 VI 1—.4 a 1 r q I Operating range V 25-48 25-58 m /y LU Min/max start voltage 6 30/46 30/58 OC N 1.f.f Mae input DC voltage V 50 80 N N Max DC current'[module Ise] a 15 tat O ever.ohaoe class DC port n Q rA 0 :x DC port bacdeed current ma 0 I-1 le-I 1 IC M PV array configuration lot ungrounded array.No additional DC side protection regulred:AC sae protection requires max 204 per branch circuit > CC 1.1 CC i� Peak output power VA 245 300 330 368 384 368 Man contbxrour output power 64 240 290 325 349 380 360 Nominal IL-LI voltagevrange• v 240/211-264 208/183-250 Max continuous nutpon currant a 1.0 1.21 1.35 1.45 1.58 1.73 N Nominal frequency ro 60 Z IQ8 Series Microinverters Extended fren°arc9range U. • 50-66 s Max emits per 20A(L-L)branch circuiC 16 13 11 T 10 5 u Our newest 1O8 Microinverters are the industry's first microgrid-forming,software- Total harmonic distortion 15se Q l0 defined mlrroinverters with split-phase power conversion capability to convert DC oyeryanage taxi AC Port n o� power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to Install0 at o is our proprietary application-specific integrated circuit(ASIC)which enables the •Lightweight and compact with AC pat backleed currant m4 30 m sf microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor salting 1.0 O 2 m tit,. 55nm technology with high speed digital logic and has super-fast response times •power Line Communication G.id-rwd power factor(adystable) 0.85 leading-0.85 lagging 0 m E E to changing loads and grid events,alleviating constraints on battery sizing for home _ 4 8 E.,(PLC)between components Peak efficiency x 97.5 976 ins 9z9 97 a 974 a. t u 0 energy systems. u ea L •Faster installation with simple CEC weighted ef8chency i 97 97 97 97.5 y. 97 Y two-wire cabling Night-time power consumption mei 60 O VI r.0 W v.,0 ir 10 l:,t:�� co ¢ coco i n ' Enph High productivity and reliability Ambient temperture range -40°C to•60°C(-40'P to.140.F) to z p 0 •Produce power even when the Plea on)v.rodlty range 4%to 100%(c°ndenvrg) ¢ G t. grid is down DC Connector type MC4 N O •More than one million cumulative Dimensiena(Nxwam 212 min(8.31x175 mnrt6.91a 302 min(12 o O1 o0 ¢ Part of the Enphasa Energy System.108 Series 108 Series MArdnverters redefine rel'mbiity hours of testing ti er O co Weight 1.08 kg(2.381bU < 00 Microinverters Integrate with the Enphasel0 standards wtth more than one million j Battery Enphasela Gateway,and the Enphasa cumulative hours of power-on testing, •Class It double-Insulated Cooling Natural convection-no fans N App monitoring and analysis software. enabling an industry-leading limited warranty 1 m of up to 25 years enclosure Approved fa wet locations yes w c V •Optimized for the latest high- acoustic noise at lm .6o de4 powered PV modules 0 Q PoIks[lon degree P03 LL Enclosure C.Iass II soubte-ins°toted,corrosion resistant polymeric endamre Mlcrogrid-forming (i k f I I l f I) • Envtron.category/UV exposure rating NEM4 type 8/outdoor •Complies with the latest 11.1 1 advanced grid support A CA Rule 21(UL 1741-54).UL 62109-1,UL1741/1EEE1547,FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 N0.107.1-01 O Connect PV modules quickly and easily to 108 Series MiAI°inverters are UL Listed as •Remote automatic updates for IA 108 Series Microirner tors using the included PV Rapid Shut Down Equipment and conham the latest grid requirements Cernlcatlass The product is UL Listed as PV Rao)401ot Down Equipment and conforms with NEC 2014.NEC 2017.and NEC 2020 section N 0-DCC-2 adapter cable wthplg-npleyl4C4 with various reputation,when entailed 690.12 and C22.1-2018 Rule64-218 Rapid Shutdown of PV Systems.for AC and DC conductors.when installed according to ,p connectors according to manufacturers mabuctlona •Configurable to support a wide manufacturer's instructions. > C'e[n range of grid profiles (t)The 10811-209 variant yell be operating et grid-tied erode only at 208V AC.(2)No enforced DC./AC ratio.See 0 2021 Enphase Energy.All rights reserved.Erphase,the Enphasa logo,I06 mcrobwerters, •Meets CA Rule 21(UL 1741-SA) the compatibility calculator at httpsl/ink.enphase.com/module.corepatibkty(3)Mammon continuous input tt and other names are trademarks o1 Erphase Energy,Inc.Data subject to change. requirements DC current is to e0(4)Nominal voltage range can be extended beyond nominal II squired by the utility.(5) t Limits may vatµ Refer to local requirements to define the number of microinvertera per blanch b1 your area. 1088E-DS-0001-01-EN-US-2021-10-19 108SE-DS-0001-01-EN-US-2021-10-19Pr I RACKING&RAIL CUT SHEET to I— Ill 111 _ I to i' IRONRIDGE XR Rail Family XR Rail Family 2 D The XR Rail Family offers the strength of a curved rail in three targeted sizes.Each size supports specific V enter Is Notlalwr aye Sunny design loads,while minimizing material costs.Depending on your locatio n,there is an XR Rail to match. o vl 1— Over their lifetime,solar panels experience countless u CO Cf extreme weather events.Not just the worst storms in years, LIJ ' but the worst storms in 40 years.High winds capable of n ripping panels from a roof,and snowfalls weighing >Y : 'n enough to buckle a panel frame. XR Rails are the structural backbone preventing ,ia a xRto xRtoo xR11xp et these results.They resist uplift,protect tt r + w against bucklingand safelyand efficientlyy'' nc g .'. , } } } %R10 is a sleek low profile mourning XR100 is the ultimate residential %R1000 is a heavyweigrn among transfer loads into the building structure. ; 1r 7"*"..i y aN,designed for regbns wth Ight or mounts g to l II suppo s a ra ge of solar mount ng rolls.it's built to handle Their superior spanning capability nos ow It achieves a loot spans whoa wind and snow co Mlibns whit also enreme tumatea and spans 1z feet or ., ,, '« remaining light and ecoromicel. maximinng spans up to 6 feel. mom for commercial applicalans. requires fewer roof attachments, . reducing the number of roof s spoon ng p b Xry • e'spanning capability 2'spanning capability penetrations and the amount ,, • Moderateloan ap.b06, Heavy load cape a y Ex name loatl c pebil y to �, „ <`"» ., Clear 8 bl k odizetl finish Clear 8 black anodized finish Clear en places I'nish Z of installation time. nternal splices available memal spkces availab a nlernal spl ces available g Rail Selection U N Q s'q ' The following table was prepared in compliance with applicable engineeri ng codes and standards.Values are ~' �, o f based on the following criteria:ASCE 7-10,Roof Zone 1,Exposure B,Roof Slope of 7 to 27 degrees and Me an Oj m ¢' a Building Height of 30 ft.Visit IronRidge.com for detailed span tables and certifications. 21 O m E c Force-Stabilizing Curve 100 ' o w » , sloped roofs generate born venlcal and lateral 120 • Q 1 forces on mounting ra 15 wh,ch can cause them Z M bend and by sl The curved shape of XR Rails None OQ Q Q ,,,......., 140 XRTO XR100 %R,O0,, _ s sp ally d 'greed to ncreese strength in both .... J�reclions while resisting the twisting.Tiros unique 3 3 mature ensures greater securrry duri g extreme 160 ,1 is 8 e a , weather and a longer system liletme. 10000 Q c, 00 y: € 120 74 i f '^ ', 140 v c v 160 100 1 j >-�- - 160 w Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials pp qq %R Reds are - - ,e Ironnidge omen Al XR Rails are made of 6000-series lilt f 40 ricompal,ble with h, i. a rangeof lif leg alum num alloy,then protected with an 160 •�,; ,a vt A'kFlashFom andforflatsud >��ii other pitnedroof roof mounting and stvcNral corms on wh'le also prov Oing $Q-]Q tsQ at ---, applie 1 na. a mare alfraclve appearance. - ? """g 80-90 11X1 aM", 48::' RACKING&RAIL CUT SHEET tr) I— I-i w tr1 IRONRIDGE Class A Fire Rating Frequently Asked Questions 2 I— D o. U What is a"module type"? What attachments and tlashings are deemed w Background compatible with Class A? w o 11 The new UL1703 standard introduces the concept of a v+F 5 PV module type,based on 4 construction parameters Attachments and their respective(lashings are not f All roofingroducts are tested and - " u,rn Cr P and 2 fire performance parameters.The purpose of constituents of the rating at this time.All code-compliant 7 classified for their ability to resist fire. Test Setup this classification is to certify mounting systems without flashing methods are acceptable from a fire rating cc'^ LJJ Solar Modules to test it with every module. standpoint. r`�y Recently,these fire resistance standards solar modules are given a Type H N were expanded to include solar equipment ciassifkahen based on their ¢m Cr) as part Of the roof system.Specifically,this ,. materials and construction in. What roofing materials are covered? What mounting height is acceptable? 0 o 0 requires the modules,mounting hardware Mounting system -� `� and roof covering to be tested together as Mo°m nq is tested as pan of a 'u: All fire rated roofing materials are covered within this UL(ire testing was performed with a gap of 5",which is CL system that incmaes type-testae certification including composition shingle,clay and considered worst case in the standard.Therefore,the w a system to ensure they achieve the same modules end Lire-rated root coven g. cement tile,metal,and membrane roofs. rating is applicable to any module to roof gap. ac fire rating as the original roof covering. Root Covering Roof covering products we given a These new requirements are being adopted ,. Fire aass Raring or A.a«c based What N I have a Class C roof,but the jurisdiction Am I required to install skirting to meet the fire throughout the country in are b2016 on theb tested r a resistancre. now requires Class A or B? code? Generally,older roofs will typically be"grand(athered No,IronRidge achieved a Class A fire rating without any 1rt Burning Brand Test in",and will not require re-rooting.However,if 50%or additional racking components. Z Iron Ridge Certification more of the roofing material is replaced for the solar 5 011.1 installation the code requirement will be enforced. a What determines Fire Classification? V IronRidge was the first company to m receive a Class A Fire Rating—the highest ® Where is the new fire rating requirement code listed? Fire Classification refers to a fire-resistance rating I— o possible rating—from Intertek Group plc.,a system for roof covering materials based on their ability ei o Nationally Recognized Testing Laboratory. � 2012 IBC:1509.7.2 Fire classification.Rooftop to withstand fire exposure. m < 2 A burning wooden block!s placed on module a elan bows et 12 mph. mounted photovoltaic systems shall have the same tire 0 , m to Flame cannot be seen on underside of roof wMwt 90 minutes classification as the roof assembly required by Section Class A-effective against severe fire exposure 0 - IronRidge Flush Mount and Tilt Mount O - E 1505. Class B-effective against moderate fire exposure m Systems were tested on sloped and flat - ------- ---- ---- Class C-effective against light fire exposure a .2u `o roofs in accordance with the new UL 1703 Spread of Flame Test u co `i &UL 2703 test standards.The testing Where is a Class A Fire Rating required? evaluated the system's ability to resist What if the roof covering is not Class A rated? p N • The general requirement for roofing systems in the IBC O W W W Z flame spread,burning material and ro f a • refers to a Class C fire rating.Class A or a is required for The IronRidge Class A rating will not diminish the fire ¢ structural damage to the roof. ui Zoo ¢ areas such as Wildland Urban Interface areas(WUI)and rating of the roof,whether Class A,B,or C. o¢ Q Refer to the table below to determine the for very high fire severity areas.Many of these areas are found throughout the western United States.California What tilts is the tilt mount system fire rated for? p` e requirements for achieving a Class A Fire has the most Class A and B roof fire rating requirements, ia 3 Rating on your next project. Flame al southern edge of roof is aimed up the roof as a fan blows at 12 due to wild fire concerns. ¢ 9 T mph.The name cannot spreads feet or more m 10 minutes. The tilt mount system is rated for 1 degrees and up and < '7, c' m any roof to module gap,or mounting height. ,..i i g rn ._W_____."". „"'"' Are standard mid clamps covered? ry C u.mi o c a System Reef Step*' ,�- Mid clamps and end clamps are considered part of the en o - - - --- PV"system",and are covered in the certification. LL • Flush Mount I Any Slope Type 1,2,&3 Class A 111.1 l Mme.neS011MOS `m w Tilt Mount I Installation Manuals Engineering Certification Letters a a 6 Degrees Type 1,2,&3 Class A Visit our website for manuals that include UL - We oNer complete engineering resources d sa 2703 Listen and Fire RatingClassification. and pre-stamped certification letters. m 1 kttasa: 9 p nlped __._. ........ ... .... ......_.... ......._...._.. .___... __. __. Cr r,. rr _,.. G.,t,-lrer fi d,ir.,,rrr' - RACKING&RAIL CUT SHEET H W IRONRIDGE System Diagram «nl N UFO Family of ComponentsKg • •__`®y_ _ •__ D U Simplified fas mindinu for F"fr,i,'A tviiration wo d The UFO family of components eliminates the need for Q: 5 AILIW separate grounding hardware by bonding solar modules IIB"I�iIill�iiillll (tiff a -,m directly to IronRidge XR Rails.All system types that feature s cc, W the UFO family—Flush Mount,Tilt Mount and Ground ry Mount—are fully listed to the UL 2703 standard. �� __ m__ __ _ w o UFO hardware forms secure electrical bonds with both the o o p module and the rail,resulting in many parallel grounding ri paths throughout the system.This leads to safer and more reliable installations. O (�___( � _ _ • 0 v Stopper Sleeve Universal Fastening Object(UFO) to I The Stopper Sleeve snaps The UFO seMttetv bonds solar modules to XR _ Z onto the UFO,convening it into Flails Its. comes assembled and lubricated.and 0 _l...[ __, g a bonded end clamp. can fit a wide tango of module heights 0 u ~ rtI Q o xy r tv o QUFO Stopper Sleeve •GroundingLug0 ; c , PP m Bonded Splice _ Ground Wire O w' = > o v d L u o 2 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for 0 co LL grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the _e same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details. S ut N y R.' n 03 2 W re' UL Certification 1"' a a _ , .d'A•..� ..:usompatibitity .ate a- GI ,t' ' . e The IronRidge Flush Mount, XR Rails ' ' J thittliki a a Tilt Mount,and Ground Mount m Bonded Splice y Systems have been listed to UL > f m XR1000 Only Earh Bonded.Sake omm w. ry 2703 byIntertek Groupplc. UFO/Stopper .i a seN-tlriNing screws to form Fa u a secure connectiontrap neon No '".. ,r Bonded Splice d J N/A 8 bonding strap needed. ; � ya UL 2703 is the standard for P � `o evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array LL systems.It ensures these devices , ) .�- - - Microinverters Enphase M7,0-�2.M�50-60,M215-60.C250-72 . Grounding Lug will maintain strong electrical and &Power Darfon MIG240,MIG300,G320,G640 + 'V A s ngle Grounding Lug Bonded Attachments mechanical connections over �' W.ck..M Optimizers Sn.arEdoe P9)0 P320,P400,P40F P600,P700,P730 E connects an entire row The bonding bolt attaches an extended period of time in 19 of PV modules to the and bonds the L-loot to the grounding conductor rail.It rs installed with the extreme outdoor environments. Fire Rating I Class A Class A N/A „°, ( me socket as the rest of the >- ._J `'».,., setem Tested or Evaluated with over 400 Framed Modules °i a)GO tO Irourli{.Ige.curn/(,ti�a Modules Refer to installation manuals for a detailed list. j x STANCHION-ROOF ATTACHMENT CUT SHEET to H w ! w 2 tt V t 0 �j -C t The strength of the S-5-E clampis in its simple design.The m LjI g p g patented m setscrews will slightly dimple the metal seam material but will not U puncture it—leaving roof warranties intact, re LLI The Right Way! 9' a Mil '<ff, III , t[1Cf ''nn it N w V+ the 5-5-E and 5-5-E Mini clamps are each furnished u)� with the hardware shown to the right,Each box also I I I v The Right Way! // 3 ndudesa bit tip for tightening setscrews using an MBA zsx ism Lil f I tl, electric screw gun.A structural aluminum attachment Hax rl"'a.e°M - i 12xl ras't M n o clamp,the S-s-E is compatible with most common a '',. Tnr..d.a Mob O /� ,/ metal roofing materials excluding copper.All included .!� .. S-5-E Clamp hardware is stainless steel.Please visit www.5-S.comfor ,� f'/ u P M d Two rma-x o so• CC s more information including CAD details,metallurgical rr a,vpasmm `r The 5-5-E clamp is designed specially for double-folded standing seam for and specifications. ,,. /Z often"' roof profiles having the appropriate The 5-S-F and S-S-F Mini clamps have been tested for t IS" `-c-- dimensioning. -. load-to-failure results on a variety of double-folded iao.somin f t,�(yl Although a bit smaller and less t,J " ' standing seam roofs,from leading manufacturers of 1 oeo I i 7 sts N expensive than the S 5-U,for these panels and panel-forming machines.The independent lab Ps oo^m! 'I` !'j}} �., -.I Z O profiles,the 5-5-E is just as strong. test reports found on our website at www.5-S.com prove t l( 4 n that 5-5!°holding strength is unmatched in the industry.0 The 5-5-E is perfect for use with S-5!" oso "-- ' is000 naafi L. ColorGard'snow retention systems and �. �Ts'mmi o.as- f — riii f other heavy-duty applications. i2500Inm! is.soon) J m. CI CD Installation Installation is as simple as placing the > __ a E clamp on the seam and tightening the O patented round-point setscrews to the Ex , c : - ,:,r,e:a H _ 1O or 4.. specified tension.Then,affix ancillary l - _ O E c Lit items usingthe boltprovided.Go to ess-,.zs x tr oo EL. v o w =, Pat n.xFl.nc.sort -c u T. E www.S-5.com/tools for information and ':*g ''S,crimptheseamtoIS5 ,i u m I. • C tools available for properly attaching !i�' degrees at desired champ �e ' and tensioning5-S!clamps. k — kcal"" rds-i.zs o w w • P —'- •, rr rr d .a noioo mmil '� Thra.dw HM0 m Q m z a "� E a I q.°�,n aye rt,�r,'. - - i�l) 0 '`�`-- I ol,o zas za x o uo• av _ _....... fw"'-ems. .t n., - (� _.__-,f'" noted-edas - ry v O 'I - 1.Is" 0 . R SE -S-E Mini Clamp u) 1Jeeemm! '«„^w. a a o - The S-5-E Mini is a bit shorter than the ! t a on S-S-E and has one setscrew rather than } ( °60n 1. .-1 > S to ✓ two.The mini is the choice for attachin i its tame + (if;,N `� o m 4 co all kinds of rooftop accessories:signs, M `u v .°:, walkways,satellite dishes,antennas, -- - l. oao ! LL o CI rooftop lighting,lightning protection _ �''-i�sa I o ss- O systems,solar arrays,exhaust stack The S-5-E clampis 097. 09e mmi • bracing,conduit,condensate lines, secured with our patented M tzsos mmi t0 mechanical equipment—just about • anything!' round-point setscrews M W without piercing the ' c yh Please rwta All meawrements are rcvnded b d,e semnd decimal place ..c metal roof panel,thereby N r __J CO S-St^w.ml P se use this duct re sib w 17 tis,malarnosare wx mmoxhlewm...neMaud n preserving the roof r ay p° t°° tyt Distributed by be used AM'S SISnWae-,5ndFermr'eredafcard'mo., a•adcatl.•e aroitpro9 P U.s. df.•eta P•famf.vna,na-eD,;w•<- SS , > 3'" a) r.mM,,,wasems manufacturers warranty! o.a;mm sk.a. a.aaw,f.r> .Im.mMlel sn.wn.r Mva n co be knro•M,•r. aM.,tMw.m mMt41 o•aperfet.:9mp rftu.•w wntea,MvtlM Co .e fork..omr•wrro•w.-,a,rn..s.«an,•.a,a,ln<.,>vaa,.Ma.wdoa nw.a.f W MOtwnwlaaw�Se;rtnae.wa H�.aedrernxf•9•MMlm.awWx MfrtN.G»tMtM3P. t� �b s-x... w9.rrw,.wan.s aM.,k.m,n. t 4� i9 • W gft O;.Sr,o* 53 ax M ... M1t>Hmy^qua WKe�CI�."S AC COMBINER CUT SHEET ui . I— U..1 LLJ - 1 Enphase IQ Combiner 4/4C el t.10DEL NUMBER /— EnililAr: CdplAolrk IN I•D,C,,,,,,,,4,,),If,0,,,2,I,)h, i ir,,,,,,,,,,r r ccrl,fr•511,,s,,,C,,,,,,,,,,,,crrtedcrt,,,,,,,,,,,,,,,,,,,,,e1 re.re,,,,,,,,,%,,,:,,,,,,,li,,,,,,,,ftrrIC(ANC, CC . 1P)20•••••, 2:•••••d,,••••••••c•:•••••,,,,,,,,,,,.:t•tt r50,1,,a,,,,,,T,,lar ,cr to TQ r,,,Sy,tonCT,,I,orlef C,,,,,i Tr,ri,r1,,t,t, CZ 0 CL u.11 u- — Ul 1- ,r,v,,.,,10,.•EM,,,,0,,CF,CS,3,,,,,,,,j.,,,,y:,,,,,,,,,,,,,,,,ir,,,,,,,f,,t5KEE,,U1K,I,,,,,,,,,,rt,,,, D Enphase i he E,,,,,,,s,I()f;ornbiner 4/4tl:with EntlrE35.,E., AttCESSORIES AND RrPt.',GENIE NT PARTt, •,,,...,cc'rrci,c1.c,rtle i 1,,,,,,,,,, CC U1 1..1J IG Gateway in integraied LTE lvl I cell IQ Combiner 4/4Cmodern(included i:•nly with iQ bie•:4•lin i:ii,,,,,,ii ii,iii;•••••••,e 1,,51,,,,,,,C,C1511,,,TIT,,,WO CELLMOL,ET,M r Cc,Trrr CT Tcrr 5.,c 5C,rr,Ca,,,r,r r5r " U.1 0 1,,,,,,,,MI,,,,,,,,or, 4G kr,S,/ X-1Q-At141-240-4 ,7r,n9()Iidates irueroonitection equipment C-CLLTAC,CEM M,05.55,OC ,IG ,ITe.,1,TE MI,,,i.il,,,,,,,,,,,,,,,,rter T,r,,,,,,AT EM 0 V) -- 0 X-1Q-AM1/11-240-4C i,*)a:Angie enolot3uro,and streamlines IQ -,.I 1,,,,,,t r,-,,,or,,r.r A,I--,ITT,rik;iD .-I . l'I '5, AR715 noicroinverters aild storage insialiatlims 1)y Ce LU providing a consistent;pre-wired solution for re •f•p;ii-: C.,,,,rine cacrim,,,,,,,,,,,:fim,roit,T,Tr on,r,,,,,,,,,,,,,or:crArt nai::irlerfinal aufilicationii,Itoffers up to funs- :ter .1 ',.-tiole input oircul is and[tut Fill,series ,....or y r tcep,teit I cr,,,,er I in.,,CEHKEE•4i0CZKEKEKEE,4Eli.',,t,,,,,,,,,,,,,,,,,,,, hussarasserrthly X.IT,,,,,Ir,r:25i, !,,,,,,5,,,,,Itr.c,,,,Ira,cr,.,it r,•,,,,,,,,,,iCf0h, in.„......,..,... , , • El.PC T Cott Ai SPE,!FIcaTioNS Z Smart..........., .. .. . •IrKittdes 1Q Gateway Crl ournmurucat.ort and ttotrunsi U 1,4 Erst,5,BC$0,2K bt,,,, ,,,; QT, •Inudes itephare Mobile Connt,t cell,Aar moduin ,, < t‘r rCELL1.401)EM MI tUt•SP 01..included oily with IQ 6.:, I" 0 I, tt.orrbiner 41t St.0•,s'o,..:.,,ol;f:CTII,,11KI,J4f1,1EPV,104;KKE) ,KE 0 w c, lig:F- I •In-union sole,shied to icatch Enphase IQ Battery so A > -1'- orl 1 •:::0,...-- aestliettits and deflect'Itear .T.,,,,c,F,,,,,,,,,,,,,.3,.Ir.,str,r,,,,,, it,,•ou•2,0,rat,•nt, ri,..,DiTcrl ,,Ger,e,r3.1.5,,Cro, ,,,,,,,ry,,,,,,,,,15,1,, _5, 2 gi* •Flexible networkillg supports WI•ri. Elbe:net,or ceiluie,. 2 5 i , ?,r0 ,—1,,.,-,..r.tiT,CT ft,,,,,,,,,,,, 5,.... ,d I.,,,,,,,,I lt,rOfiat,,,,3',, Pit ,...511 . •Opoo,sI AC lE,Cepta,le:tva.ltitue for PLC bridge 0- 2 L.) 0 •Provides aped lemon metennti and consumption u co T.. i MECHANIf,A DATA InOrlit0Ong -NC ' 6,,r.rrio,,,-,,,,,,T.,t,, ,:5,5,T,,t,,,,,r53.,.IT 5.K E 6-T r,'Icisr,,N2D.,••••'64,5 ,TrIr, ,c,r,r, W r2 2 . wz co 4 , Simple ur; < 0 0 a 200 •cie,t,,....:mounting brack,As support siVe < < —t. stod mounting IrTTc.,tvce JP,PEreCOE,K1Cii, •hapports bottom.bank and side conilt,,I entry r 8 tc1 3 •lip to four 7.poi',branch citruits for 240 VAC 4 , -- plug.in brlialoTIS;not inCIU:14,151 . ell t 4 . ,.:.,..: ..,„,,,,,,,,,,..,, •Ban ion-PV or storage 1,1,0ch cc,r1J115 . ., 2 IN •n-, 0 U ; Relied*, 11,11Entat I,:ONNECT ION OPTD.,14,:t ' 2 ' ••. •Durebie NRTL certified NEMA type:IR enclosure ]. •Fo:e.vear Room:warranty ,„.............., lif •Two yeais abor reinsbtrsement ploortro coverage ineludud for both del')Comblruu St„U's >" COMPt Diticr : •llt.hated , W ,T, r,,,,,,,?1,,,,,,,,,r,..,IS cr,,,,,,r,-,,,,, ;I J, (!) l0-IQ-M,11-24P-t 2.. 1.12TrIl „I To learn More about EnpflaSe Offerings,visit ellphaSe.01)110 N....."ENPHASE t,, , r'4Am,;.)I,,ng,,,vinil E,Ilphatie COTT, e ENPHASE > 00.1 . ... . . . , , . k_AdTT PPP AC DISCONNECT CUT SHEET II-2- IF =T•N �•j . Switching Devices Lu Safety Switches I- Powering Business Worldwide :; - m D `t - `=$a Standards and Certifications . U General Duty Non-Fusible UL tedFileNp E5739 °� 0.11 general-0ury switches w d .. above 100A end ell heavy- • Meets UL 99 fol ckisen y,F, Safety Switch duty switches incorporate Switches and NEMA std <-these feature switch r-( KS 1 C DG222URB design features. w .",' _ Tv✓<,x it is of contact IIL �'^ w— Y F provide a pot t ye r a UPC:782113144238 a ripe end cote,easier N Opoution,and also help I-N Prevent Con;a^,t burring pearly Y'we Me•/N ' _ Q°p r-• Dimensions: IIWi gin for longer contact life pp5';.pn ION Or OFF! MNdodin66NeMpi..r Seismic Ous/i/iMxoet 0 • The • 'Krn 'ea s f • Doe cannot be opened General-duty lines a-1 t"i Y '""••"'�" y who the hanile is in the d the y ant •Height:7.5 IN cc and the length f u,r ,u u ry CC ' __ c p n. I•:r,•easy opelaton ON pot ton Front and Code RAN:l nd California w side operable.Length:6.41 IN "" mechanismro ides Ode Title012 1C osR-0m1 to, pli.•Width:8.4 IN ,ytisrr o1z-10 for lte access Welght'9 LB throwsr switches snyle ■ l �."°� necessary al tithes pe.eaton corn ee, ° Notes:WARNINGI Switch is not approved for " °8, ,°;;K�;",� alt viz M.service entrance unless a neutral kit is installed. ore It aganst accidental f r—•,: 5 contact with energized Triple P•Ileckm.C paHrrr ,, ..* 1"% Warranties: d parts.probe Ito irs enable the user to test It the line • R mel sa t feature U • Eaton Selling Policy 25-000,one(1)year from sides energized without because the large hasp car Q re removing the shield accommodate up to J ,.., the date of installation of the Product or Not provided on yenera three locintl119.5 mn+1 2 i ,alxewe°e.n O y O duty soothes,tit thane locks m > Q eighteen(18)months from the date of shipment available as a field kit • An ample number are > c f or factory installed ;".• provided on the top, 0 bottom and sides of b:,th iti of the Product,whichever occurs first. ' NE MA Types 1 and 3R 0 > H 2 Specifications: to r t' enclosures through zooA v U '6 •Type:General Duty/Non-Fusible wi' tit 3 •Amperage Rating:60A " - o '" W z •Enclosure:NEMA 3R : AdthIe rtwu. C.p bdity �,,,,.. - co Z o 0 Q •Enclosure Material:Painted galvanized steel Veer,,-Shield • Cabnet rho!can befnrtner a a padlocked at the top and •Fuse Configuration:Non-fusible bottom as applicable _ 8 t sex-a°wxro •Number Of Poles:Two-pole • For switches Ina NEMA e a o a0 sr Type 3R,30-700A.Use rn ,- Q m > 2 'n •Product Category:General Duty Safety Switch all others ' o d isT d v 2 _ •Voltage Rating:240V " o Supporting documents: I?: •Eatons Volume 2-Commercial Distribution •Eaton Specification Sheet-DG222URB Certifications: us • UL Listed d i Product compliance:No Data V2-t1-26 Volume 2—Commercial Distribution CA0,10Ce11E—May 201a wmvearoocae kt ©2016 Eaton.All rights reserved.