Loading...
36-236 (3) BP-2022-1437 25 DIAMOND COURT COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 36-236-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1437 PERMISSION IS HEREBY GRANT:D TO: Project# WOOD STOVE Contractor: License: Est.Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp.Date: 01/06/2024 Use Group: Owner: BARKER GILLETTE, CHADBOURNE ,' JULIE Lot Size (sq.ft.) Zoning: WSP Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 01400503301116 WHATLEY, MA 01093 ISSUED ON:11/02/2022 TO PERFORM THE FOLLOWING WORK: WOOD STOVE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: . _52 . . Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner 6), . City of Northampton Massachusetts /1/ ` '.7.., v t } e fig�. R tJ9 DEPARTMENT OF BUILDING INSPECT ®+ e a: t; iJf � _ 212 Main Street • Municipal Builtt� .9� �2 a�•. l? Northampton, MA 01060 9y�i' 0 jt Y �N A o.1 o 060/04,4, APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information • Owners Name: /.•e �•/%74lc Address: a 5 / pion 0 ('o'rr- Hare/CC A cr70' (No.) (Street Address) Phone: G/!- 33/-G51t7 Cell: Email: &Qr/f-r J��/< eye►'/ CC Owners Signature: Date: 97,23 Contractor's Information (If Applicable) Name: `0aor4s 4 Alabcc- 2 r i.it (?het Phone: //i3 3 91 5 S Construction Supervisor's License #: 970 Expiration: / .a9 Home Impr. Contractor License #: /foci 77 Expiration: 7/- /P�� Stove Information Type of Fuel (check all that apply): Wood Pellet Coal Location: f lrs' //aor Freestanding ( Insert ), �/f n Manufacturer: lops' Model: hi rrf er -//c,I &/as di(:nrncr a.,/ 5J`o �/� FOR BUILDING DEPARTMENT USE ONLY Permit# tP r�d)' '/ 7Date Applied: Total all Fees: $ LIQ C/G41/3SV Building Official: i u►iJ `Koss Date Issued: /1- Z-ZOZZ .mot) Signature of Building Official: • t rso vvrrrrrccrrc rvcccrarc cif Srj.scooccc.rsasaveco _.__._T7.— Department of Industrial Accidents '1 1 .l i.� i� . Office of Investigations Lafayette City Center 7' 3= �';1 j 2 Avenue de Lafayette, Boston,MA 0 9111-1750 ',�,l'�i,r ' wW14J.Hia,LIs.gov/dh! Workers' Compensation ;insurance Affidavit: Builders/Contractor•s/EIectricians/Plumbers applicant Information Please Print Legibly \Tame (Business/Organization/individual);THE FIRE PLACE .ddress:100 STATE ROAD airy/State/Zip:WHATELY, MA 01093 Phone i#:413-397-3463 re you an employer'? Cheek the appropriate box: Type of project(required): Q 1 am a employer with 10 4. ❑ I am a general contractor and I 6 ❑ Nevi construction employees (full and/or part-time).* have hired the sub-contractors ❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me In any capacity, employees and have workers' y ❑ Building addition [No workers' comp.insurance comp. insurance.t required.] 5, ❑ We are a corporation and its 10.0 Electrical repairs or additions ❑ I am a homeowner doing all work officers have exercised their 11.[] Plumbing repairs or additions myself. (No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance.required.] .t c. 152, §1(4), and we have no employees, [No workers' 13.❑ Other comp. insurance required.] ty applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. omcowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a now affidavit indicating such. uttractors that check this box must attached en additional sheet showing the name ot'thc suh.contractors and state whether or not those entities have rloyecs, If the sub-contractors have employees,they must provide their workers'comp.policy number. in aiz employer that is providing workers'compensation insurance for my employees. Below is the policy and job site "ovulation, turance Company Name:MA RETAIL MERCHANTS WC GROUP INC licy#or Self ins. Lic. #:01400503301116 Expiration Date:1-1 23 laSite Address: v S'//l/rho>� (arn'� City/Stine/Zip: /�a1eY , J :tacit a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). ilure to secure coverage as required under Section 25A of MGL e. 152 can lead to the imposition of criminal penalties of a le up to 31,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a tine up to S250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of vestibations of the DIA for insurance coverage verification. to hereby c•ertkzruler t(r `airs ang p naltle ofpei iuiy tint the lnfnrriuition provided above is true and correct. enature; Date: ' /Q 17';'7Z- ione#; 413-397-3463 . Official use only. Do not write in this area, to he completed by city nr'town official. City or Town: Permit/License# Issuing Authority (check one): 1.0Board of Health 20Buildfng Department 31:City/Town Clerk 4.❑Electricrtl Inspector 5❑Plumbing Inspector 6.pother Contact Person: Phone#: 6 Features & Specifications Installation Options Features • Freestanding • Single Operating Control • Freestanding in an Alcove • Steel Plate Construction (1/4" &3/16") • Freestanding in a Mobile Home • Heavy Duty Refractory Firebrick • Optional GreenStart Igniter • Optional High-Tech Blower Heating Specifications Approximate Maximum Heating Capacity(in square feet)* up to 2,000 (185 square meters) EPA Tested Cord Wood BTUs per Hour** 12,772 to 70,720 Maximum Burn Time Up to 10 Hours *Heating capacity will vary depending on the home's floor plan,degree of insulation,and the outside temperature. It is also affected by the quality and moisture level of the fuel. ** EPA tests to determine BTU output are achieved with a single load of wood at each burn rate.At home,you are likely to add more wood to your stove to maintain your desired comfort level. By the simple process of loading your stove with additional wood,you could achieve up to a 20%higher heat output than established during EPA testing. This model was tested for efficiency using method B415.1-10 and was determined to have a weighted average Higher Heating Value(HHV)Overall Heating Efficiency(OHE)of 77.1%. Overall efficiency of the heater may be lower if the heater is operated without a heat exchange blower or with the installed heat exchange blower turned off. Dimensions 5" 28" 5" 28" O 127mm 712mm O 127 m 712mm 1-1/2" 6"Dia. 1-1/2" 6"Dia. IN,444444. 39mm 152mm 39mm 152mm Cr Or 20-1/4" 20-1/4" 515mm % 515mm � 33-1/2" 1 31" Imm 851mm788" il iiii iiiiii. o o (a) Side, rear and corner clearances are measured from the stove top. (b) Rubber-Tipped Leveling Bolts (at each corner). Emissions This heater meets the 2020 U.S. EPA's cord wood emission limits for wood heaters. Tested to EPA Alt-125, FM ASTM E3053-17, ASTM 2515-11, CSA B415.1-10 this heater has been shown to deliver heat at rates 4,_. ranging from 12,772 to 70,720 BTU/hr and an emission value of 1.52g/h. Report No. 0028WS119E c,,,L ©Travis Industries 5/27/2021 - 1498 Evergreen Stove Installation (for qualified installers only) 7 SAFETY NOTICE: Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Planning the Installation e We suggest that you have an authorized Travis Industries dealer install your stove. If you install the stove yourself, your authorized dealer should review your installation plans. 8 Check with local building officials for any permits required for installation of this stove and notify your insurance company before proceeding with installation. 8 The location of your wood heater in your home will decide how effectively the heat produced will spread throughout your house. Attention to the home design with consideration of natural convection and air circulation should be taken into account when choosing the placement of your heater within the home. Preparation for Installation • Make sure the baffles are in place. • Check for damage to the exterior of the stove (dents should be reported, scratches can be fixed by applying touch-up paint). • Check the interior of the firebox (replace any cracked firebricks and make sure the baffle is in place). O The stove can be lightened by removing the firebricks - replace before operation. Packing List • Wood moisture meter • Bypass Tool • Ash Dump Tool • Igniter Cover Plate and Cover Box • Gloves ©Travis Industries 5/27/2021 - 1498 Evergreen Stove Instal . On (for qualified installers only) Floor Protection Requirements • Floor protection must extend to the sides, rear, and front of the stove (see"Clearances" below for minimum floor protection). • Floor protection must be non-combustible and at least.018" (.45mm)thick (26 gauge). Stove Placement Requirements Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials. • Stove must be placed so that no combustibles are within, or can swing within 36"(914mm)of the front of the stove (drapes, doors, etc.) • If the stove is placed in a location where the ceiling height is less than 7' (2.134M), it must follow the requirements in the section "Alcove Installation Requirements" • Must maintain the clearances to combustibles listed below(drywall, furniture) • The stove requires an air source to operate. Combustion air starvation will result in poor performance or smoke in the house. Clearances • The following clearances must be met (see Figure 1 and Figure 2): Minimum Clearance Single wall Reduced Connector Clearance* A Sidewall to stovetop 12" (305mm) 11" (280mm) B Back wall to stovetop 17" (432mm) 9" (229mm) C Corner wall to stovetop 8" (204mm) 4" (102mm) D Connector to sidewall 22.5" 572mm) 21" (534mm) E Connector to back wall 19" (483mm) 10.5" (267mm) F Connector to corner wall 17.5" (445mm) 13.5" (343mm) G Floor protection side and back 6" US/8" Canada 6" US/8" Canada (153mm /204mm) (153mm /204mm) H Floor protection front 16" US/ 18" Canada 16" US 18" Canada (407mm /458mm) (407mm /458mm) *Reduced clearance installations require one of the chimneys and connectors listed below: AMERI-TEC model DCC with model HS chimney DURAVENT model DVL with DURATEC or DURA-PLUS chimney GSW Super Chimney Twenty-One connected directly to appliance I.C.C.Excel(2100-2 Can.)(103-HT USA)chimney with ULTRABIack connector METALFAB model DW connector with TG chimney OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney SECURITY model DP connector with SECURITY model ASHT or S2100 chimney SELKIRK METALBESTOS model DS connector with model SSII chimney OLYMPIA VENTIS with Ventis double wall black stove pipe Standard Masonry Chimney with any one of the above listed connectors NOTE:Reduced clearance connectors may not connect to the flue collar—an appliance adapter may be required. NOTE: Standard residential installations with reduced clearance connector may use the clearance determined by the manufacturer of the connector for the connector to wall clearance or the clearance listed in this manual. Offsets must be used to maintain the stove to wall clearance. ©Travis Industries 5/27/2021 -1498 Evergreen ii Stove Installation (for qualified installers only) 9 Top View - Straight Installation 0 0 (i) Measure rear and side 28" clearances from the stove {� 712mm _g top. ��rr v (j)Vent diameter varies 5"127mm I depending on brand and ._f11 10 0 model. (k) Measure front O clearances from the stove 20.25"515mm — top. I 0 O NC011)-71 Figure 1 Top View - Corner Installation (i) Measure rear and side clearances from the stove top. (j)Vent diameter varies depending on brand and 0 model. (k) Measure front 28, clearances from the stove 712nrn _ top. 5"127mm 20.25"515mm V' r�r��sre ti Y"at`Y'4"� 4 r d t r .r r«r rr xrr rr r v �4 �. �. rrr rrrma rr r-A r.s, r r xr rrrr sr rr xrar ,. ar r rr.r� rr r,rrr;z:.. Figure 2 ©Travis Industries 5/27/2021 - 1498 Evergreen 0 Stove Instal - On (for qualified installers only) Chimney Connector Requirements • Chimney connector is required from the flue collar of the stove to the factory-built chimney or masonry chimney. • The chimney connector must be 6" (152mm)diameter and a minimum 24 gauge black steel, or one of the reduced-clearance connectors listed on page 8. NOTE:Aluminum or galvanized steel is not allowed—these materials cannot withstand the flue temperatures and may give off toxic fumes when heated. NOTE: Standard residential installations may use single-wall connector(Mobile-Homes may not). • The chimney connector may not pass through a ceiling, attic, roof, closet, or any other concealed space (use listed UL 103 HT chimney—see "Chimney Requirements for details). DO NOT USE CONNECTOR PIPE AS CHIMNEY. • IN CANADA:Where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment. • The chimney connector should be as short and direct as possible. No more than 180°of elbows(two 90° elbows,or two 45°&one 90°elbow, etc.)may be used for the entire system (connector and chimney). Horizontal runs should slope upwards 1/4"(6mm)per foot and be a maximum 36"(914mm)long. • The chimney connector must be installed with the crimped end pointing downwards. This prevents creosote from leaking to the exterior of the pipe. I I • The chimney connector must be fastened to the stove and each adjoining section (and chimney). • Standard residential installations with reduced clearance connector may use the clearance determined by the manufacturer of the connector for the connector to wall clearance or the clearance listed in this manual. Offsets must be used to maintain the stove to wall clearance. Mobile homes must use the clearances listed in this manual under"Additional Requirements for Mobile Home Installations". ©Travis Industries 5/27/2021 - 1498 Evergreen Stove Installation (for qualified installers only) 11 Chimney Requirements • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. • DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATIONS • IN CANADA: This appliance must be connected to a factory-built chimney conforming to CAN/ULC- S629, Standard for 650°C Factory-Built Chimneys. • UL 103 HT Chimney must be used from the first ceiling or floor or wall penetration to the chimney cap. • Use 6" (152mm) diameter type UL 103 HT chimney from one manufacturer(do not mix brands) or code approved masonry chimney with a flue liner. • Chimney must be fastened to each adjoining section. • Follow the chimney manufacturer's clearances and requirements. • Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing through a ceiling and roof(see "b" and "d" below). • No more than 180° of elbows (two 90°elbows, or two 45°& one 90°elbow, etc.) may be used for the entire system (connector and chimney). NOTE: Additional elbows may be allowed if draft is sufficient. Whenever elbows are used the draft is adversely affected. Additional chimney height may be required to boost draft. (a) Min. System Height 15' (4.5M) Max. System Height 33' (10.058M) (b) Roof Penetration and Termination (see chimney manufacturer's requirements) (c) Chimney Sections 0 (d) Ceiling Penetration (see chimney manufacturer's requirements) O 0 (e) Minimum air space to combustibles (see chimney manufacturer's requirements— typically 2"/51 mm) O 8 (f) Connector—see "Chimney Connector" on the previous page. O 0 Figure 3 Drafting Performance Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors.Too much draft may cause excessive temperatures in the appliance and may damage the heater. Inadequate draft may cause backpuffing into the room and 'plugging' of the chimney. Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates excessive draft. ©Travis Industries 5/27/2021 - 1498 Evergreen 2 Stove Instal • on (for qualified installers only) Chimney Termination Requirements • Must have an approved cap (to prevent water from entering) • Must not be located where it will become plugged by snow or other material • Must terminate at least 3' (914mm) above the roof and at least 2' (610mm)above any portion of the roof within 10' (3.048M) (see Figure 4) Slanted Roofs Chimney must extend 2' A above any portion of the roof Chimney must within 10'of the chimney extend 3' • above the roof 1 Chimney must extend 2' Flat Roofs above any portion of the roof within 10'of the chimney Chimney must extend 3' above the roof Figure 4 Outside Air Requirements • Required for mobile homes and in certain localities (check with local building official) • Must not be drawn from an enclosed space (garage, unventilated crawl space) • Requires a 3" duct that attaches to the back of the stove (see "a" below). • Outside air duct must have a rodent screen and rain hood (see "b" below). • The Travis Industries Outside Air Kit(sku 99200139) includes all the above components. ,mum___ ____■ ►� ©Travis Industries 5/27/2021 - 1498 Evergreen Selkirk Chimney Systems (USA Only - See separate instructions for Canada) Sheet GS Installation Instructions Covering -General Installation Instructions & Owner's Maintenance Guide A MAJOR CAUSE OF CHIMNEY-RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT THIS CHIMNEY BE IN- A WARNING STALLED ONLY IN ACCORDANCE WITH Failure to follow these Installation Instructions could THESE INSTRUCTIONS. cause FIRE,CARBON MONOXIDE POISONING,OR DEATH.If you are unsure of Installation requirements, call the SELKIRK CHIMNEY SYSTEMS-MODELS, PART NAMES AND Phone Number listed on the back of these instructions. NUMBERS Selkirk Chimney Systems(SCS)consist of the following Models-UT(Ultra fully enclosed at 2 inches minimum AIR SPACE clearance to combustibles, Temp),ST(Sure Temp),GT(Galva Temp),SG Plus and SSII. including framing lumber,drywall,plaster,plywood and other building mate- The complete part number is prefixed with the ID size, in inches,followed rials classed as combustible.For support framing,see table on back page. by one or two letters identifying the system to which it belongs, followed AIR SPACE ONLY by the actual part identifier. The minimum clearance to Selkirk Chimney System pipe means AIR SPACE All accessory parts for the Selkirk Chimney System (all models)include a ONLY.The 2 inch clearance to pipe,and the spaces around supports must not letter"T" in the prefix and may be used with all Models unless otherwise be filled with any type of insulation.In attics with blown-in or batt insulation, indicated. the chimney must either be fully enclosed or an Attic Insulation Shield must All Model UT,ST and GT chimney sections(straight lengths,tees,elbows) be used to create and maintain the proper minimum airspace. contain the letters"UT","ST", and "GT", respectively in the prefix. SIZES AND APPLICATIONS All Model SG Plus chimney sections (straight lengths, tees, elbows)con- The Selkirk Chimney System is made in 5",6",7",8",10",12",and 14"sizes. tain the letters"GP"in the prefix. The four smaller sizes conform to the current edition of UL-103 Standard Type Fig. 1,2,and 3 show the names and locations of commonly used chimney HT requirements.All seven sizes comply fully with the requirements of the 9th parts. These figures use only the last portion of the part number. The Edition of UL Standard 103. Chimneys installed in accordance with these complete part number is prefixed with I.D.size,followed by chimney model instructions will comply with national safety standards such as NFPA 31,54 and part number. and 211.The Selkirk Chimney System may be used for gas,wood and liquid fuel fired stoves,fireplace stoves,central furnaces,floor furnaces,steam and hot water boilers, unit heaters and water heaters. It may also be used for IMPORTANT:Chimney sizes 5",6",7"and 8"are Type HT and carry a"T" masonry fireplaces. in the part number. Larger sizes use an"S"in the part number. These Selkirk Chimney Systems are designed for gravity venting only.They FOR EXAMPLE are usable on any appliance having a power burner(such as oil furnace)if that Model UT appliance operates with neutral or negative draft at its outlet. Inside Diameter I 36"Pipe Length Non-residential appliances which may cause positive pressure in the chimney �6UT-36' should use a Selkirk Model PS or IPS system. The Selkirk Chimney Systems,sizes 10", 12",14",are ideal for venting gas (natural and LP),#2 oil,and open front wood burning appliances. Model ST Inside Diameter I Insulated Tee \S.ST-IT� DETAIL INSTRUCTION SHEETS Details for the installation of all chimney parts must be observed by refer- All Models ring to other instructions as follows: Inside Diameter I Wall Support Kit Finish or Ceiling Supports*,Connectors S-1 ' 7T�WSK- Fire Stops,Attic Insulation Shields* S-2 Round Top*, Flashing,Spark Arrester S-3 NOTE:Use only Selkirk Chimney System Listed components Roof Support Package*,Anchor Plate* S-4 and accessories. Do not use pipe by itself or attempt to fabricate Insulated Tee*,Wall Support Kit* S-5 your own support or accessories. Insulated Elbow*,Interior Resupport* S-5 CAUTION:IF YOU ARE BURNING COAL Firestop/Joist Shield* S-7 Some types of coal in certain designs of stoves may, in rare instances, Support Box* S-9 cause corrosion of the inner parts of the Selkirk Chimney System.Inspect and *If you are installing any of these parts in packages marked*, you should clean your chimney frequently to keep it free of coal,ash and soot deposits. receive the proper instructions in the package. You may also request a Also see"Sizes and Applications"section.If damage to the flue is observed, complete set of instructions from your dealer.This sheet of general instruc- contact your Selkirk dealer or Selkirk Customer Service(1-800-992-VENT) tions is furnished with all UL listed chimney supports. It covers important with a description of your chimney problem. safety precautions in the installation, operation and maintenance of your The Selkirk Chimney System is not recommended if you are burning ocean appliance and chimney. Anyone installing a chimney should review this driftwood.The salt in this wood may cause product failure. sheet as well as those furnished with the other parts of the chimney system.Selkirk chimney parts LISTED and produced under the Factory In- MINIMUM CLEARANCE spection and Follow-Up program of Underwriters'Laboratories,Inc.carry the Where installed within buildings,the Selkirk Chimney System may be LISTING MARK illustrated here. SPECIAL WARNING ON CELLULOSE INSULATION Cellulose insulation in direct contact with a hot chimney can ignite and smolder,and can set fire to ordinary wood framing L I�1 T materials. The AIR SPACE ONLY precaution applies to all blown-in or loose fill insulations, but is especially applicable to V\ cellulose insulation,which may be made from old newspapers or other cellulose materials.The Attic Insulation Shield or a suitable enclosure with appropriate fire stops must be used to keep all insulation the proper distance away from the chimney. J,,SELKIRK 3050 Corporate Exchange Blvd. SE, Grand Rapids, MI 49512 1-800-433-6341 SELKIRK CORPORATION Round Top(CT) 4111‘b —Round Top(CT) �11 Flashing(AF)or(TF) Chimney Pipe Storm Collar(SC)— /Roof Shield with TF Storm Collar(SC) - —, I I, 4r�4P4 °4114 Interior Resupport(IR) % Full Enclosure or Attic ' I � Attic Insulation shield Area 11 Locking Band (LB) IWO �� or Screws Chimney Pipe Insulated Elbow(EL) �1) Firestop/Joist Shield(JS) Below Framing 410_ OAXIMUM OFFSETMaximum inclined Length: IAttic Insulation Shield(AIS) AT30" —g6"unless relined rted at iiiANGLE/ 48"intervals Fire Stop/Joist Shield(JS)—\ �/ Opening Framed On 3� —Full Enclosure, p All Four Sides 2"Minimum Air Space Clearance Insulated Elbow(EL) Locking Band(LB) III or Screws CHIMNEY MUST BE /�A ENCLOSED �..—____Finish Support(FSP)or Ceiling Support(CSP) Chimney Pipe FIG 3 THIRTY DEGREE OFFSET WITH ENCLOSURE AT 2" Finish Support(FSP)or CLEARANCE(MAXIMUM OF TWO SEPARATE OFFSETS PER SYSTEM) Ceiling Support(CSP) (00 � , , WHEN INSTALLING YOUR CHIMNEYAND WOODBURNING STOVE OR Dripless Smoke Pipe Adapter—\\ � FIREPLACE SYSTEM,REMEMBER... (DSA)or(DSAC) SAFETY FIRST 6",7",8"only or 5"-14"Chimney You may well have a basic knowledge of carpentry and the use of hand Pipe Adapter(CPA) tools. However it is important that you also review the rules of safety on FIG1 VERTICAL CHIMNEY THROUGH ONE the following pages. If you have any doubt about your ability to complete STORY AND ATTIC your installation in a workmanlike manner,you should arrange for a profes- sional installation. RULES FOR SAFETY DURING INSTALLATION 1. Read all installation sheets.Look for them in the cartons,or ask your dealer for a complete set or download from www.Selkirkinc.com.Keep the N��i — Wall Band(WB) instructions handy and save them for future reference. Combustible Wall— Every 8 Feet If Not Enclosed 2. Check your local building or fire code for all requirements affecting the fuel-burning appliance and its chimney. — Use Locking Bands 3.Obtain a building permit for both the appliance and the chimney.Contact (LB)on All Joints local building or fire officials about restrictions and installation inspection in your area. Max Chimney Height 4.Be very careful around electrical wiring and be sure it is secured at least 50 Feet 5",6",7"8"Size 2 inches away from any part of the chimney. If wiring must be relocated, 40 Feet 10", 12", 14"Size hire a professional electrician. 5.Be sure that ladders are in good condition and always rest on a level firm Min.Clearance —How 2 To Combustibles Full Enclosure surface. II Recommended. 6. Wear cut resistant gloves when handling sheet metal parts with sharp i i Both Indoors edges. and Outdoors 7. Be sure that electrically powered tools are properly grounded. Min.Thru Wall 4-1/2" 1.,..„ CHIMNEY HEIGHT AND SIZE Selkirk These instructions contain a"Selector Chart"so you can pick the exact ChimneyII Insulated Tee(IT) combination of length increments.A chimney for one or more gas appli- Section ances must conform to size and height recommendations in the"Selkirk Gas Wall Thimble Wall Support Kit(WSK) Vent and Chimney Sizing Handbook."Heights above the roof as given in the =L next paragraph are minimum;greater heights may be needed for reasons (IWT)Shield Ir_.tii :Eti given. Wall Thimble(IWT)401" Capped Cleanout and Before beginning installation of the chimney,be sure that the selected size Face Plate Retainers is adequate for the appliance and the selected height of'the Chimney Lag Screws Brace Round Top termination is high enough to conform to building code require- Into Structure ments. Chimneys are required to extend at least 3 feet ebove the highest point where they pass through the roof of a building,and at least two feet pJ higher than any portion of a building within 10 feet.(National Fire Protection Association Standards Nos. 31, 54, and 211.)See Fig.4. FIG 2 INSULATED TEE THROUGH COMBUSTIBLE WALL — J — . 2 FT. , 3.Appliance Support,with the Selkirk Chimney System starting at the appliance outlet.This is permissible if this method is shown in the appliance instructions, or with masonry fireplaces. --�—2 FT. II4.Wall Support with Insulated Tee.See Sheet S-5. 5.Support Box.See Sheet S-9. 10 FT. 6. Proper lateral support is also necessary and may be provided by wall /' bands, firestops, roof braces and/or all the supports listed above. Maxi- mum spacing between components providing lateral support is 8 ft (See sheets S-2, S-3, and S-5). — 4- — ` Because of thermal expansion problems,only one of these support meth- 3 FT. ods should be used for a vertical installation.For example:Do Not use both i ' \ a ceiling support and a roof support for the same chimney. ) OBSERVE CLEARANCE TO COMBUSTIBLE MATERIAL AND SLOPE FOR CONNECTOR OR SMOKE PIPE Fig.4 RULES FOR CHIMNEY The connector or smoke pipe is the sheet metal pipe between the appliance HEIGHT ABOVE THE ROOF and the chimney. Different types of fuels and appliances have different CHOOSING YOUR HEATING APPLIANCE connector clearances to combustible walls and ceilings.These clearances There are three important rules for selecting a woodburning stove, fire- will be shown in the appliance instructions. place or heater. Whatever clearances and connector arrangements are shown in the appli- ance instructions,must be followed rather than the arbitrary 18 inch dimen- FIRST Look for a label or nameplate attached to the appliance which bears sion.This is important if tests have shown that more than 18 inches clear- the mark or name of a well-known safety testing organization* or labora- ance is necessary, or if the location of the stove or heater necessitates tory. more clearance.See Fig.5. SECOND Don't buy an appliance which is bigger than necessary. Combustible materials include such things as framing lumber, plywood, THIRD Look or ask for complete installation, operating and mainte- drywall (sheet rock, plaster board, lath and plaster, gypsum board) and nance instructions for the appliance. If you can't get these, buy one that also furniture and curtains. Building insulation of any kind, including batts, gives you all these very important details. foams, boards and especially loose fill cellulose fiber, must also be kept away from the chimney in the same manner as combustible materials. *Such as Underwriters' Laboratories, Inc. or Intertek Testing Services. APPLIANCE SAFETY Use Locking r Be sure to follow all details of the instructions for your solid fuel burning Bands at Every f;3 Minimum appliance. You should give preference to the purchase of an appliance Joint %I i Clearance which either has a label or includes detailed instructions showing all re- ---a —2" quired clearances to floor and walls. If necessary, these clearances may be reduced byuse of a tested and"Listed"(byUL,for example) X p )protection t system,or by one of the methods described in NFPA Standard 211. ;; For the chimney connector, the appliance instructions take prece- L� -3 I, dence over the 18 inch clearance shown in these instructions (or in See Note s1 i' x building codes).The 18 inch minimum clearance dimension applies only if Below _Ceiling Support there is no other information for the connector. Follow Appliance (FSP)(CSP) Instructions For When protecting walls or ceilings from the heat of a connector, be sure to Clearance. If Dripless Smoke leave at least a 1 inch ventilated air space between the protection material 18t Given, Use Pipe Adapter (DSA or DSAC) and combustible construction. It is ineffective and possibly dangerous to apply ordinary brick,or any similar dense material directly to a wood framedb • —�^ Follow Appliance wall for the purpose of reducing safe clearances. • Instructions For EACH SOLID FUEL APPLIANCE SHOULD HAVE ITS OWN CHIMNEY I Nlearaven, If Use (Or Not Given, Use * Stoves of air-tight or controlled combustion design may be difficult to Smoke Pipe) / 18" operate if some other appliance is connected to the same chimney. Drip-Free Capon Cleanout Tee * Open front, freestanding or built-in fireplaces may need all the draft NOTE:The purpose of the diagonal arrows is to show that the 18 inch clearance DOES NOTAPPLY to the produced by a minimum height of chimney. Interconnecting them or their vertical connector entering a Finish Support.This support is actually tested with a bare vertical chimney with another appliance may be prohibited by their instructions and connector and must pass the UL tests with very hot gases entering the bare single wall pipe. may cause smoking problems. FIG.5 CONNECTOR CLEARANCES *Never connect a gas-burning appliance into a chimney for any woodburning stove,heater or fireplace.This is extremely dangerous because a chimney Passing a bare smoke pipe or connector of a wood burning appliance through blocked with creosote (or anything else) may cause the connected gas a combustible stud wall is not recommended,as the entire inside of the wall appliance to produce poisonous carbon monoxide. must be cut away to get 18 inch clearance(usually at least a 40 inch circle). * For these and other reasons, don't ever inter-connect your solid fuel Wherever possible,locate the Selkirk Chimney to avoid penetrating a wall with appliance with anything else, not even another solid fuel appliance.There a single wall connector.Besides following the appliance instructions for con- are simply too many things that can go wrong if you do. nectors,other rules for solid fuel appliance connectors are: GENERAL INSTALLATION INSTRUCTIONS 1.Never enclose vertical single wall pipe,even at 18 inches clearance. A correct easily-maintained chimney installation has five important parts: 2. Never run it through ceilings or floors, or windows. 1. Proper support,both vertical and lateral,with access for inspection and 3. Don't use single wall pipe outdoors. maintenance. 4.Always secure all single wall pipe joints with at least 3 screws. 2.Adequate clearance to combustible materials for single wall connector 5. Obtain proper attachment parts for the appliance end and for the entry or smoke pipe. to the chimney.See the Selkirk Chimney System catalog for the proper 3.AIR SPACE clearance of 2 inches for insulated chimney parts. size Dripless Smoke Pipe Adapter(DSA)or(DSAC),or Chimney Pipe Adap- 4.All vertical intermediate ceiling or floor penetrations completely framed tor(CPA). and firestopped with specified chimney parts. 6. Locate and support the connector to avoid accident4l contact or dam- 5.All connector and chimney joints completely secured against unlocking age. with three screws or with locking bands. See diagram for screw location. 7. Caps or plugs for tees should be secured against falling out and de- signed so signed so they can't leak creosote or rain. 8. Heavy weight single wall pipe lasts longer. Use 24 gauge if possible. Vertical chimneys may be supported in these ways: 9. Porcelain enamel is the best high temperature proterptive finish but re- 1.Ceiling Support with all chimney stacked above.See sheet S-1. quires careful handling and may be difficult to assemble securely except in 2.Roof Support,with one or more lengths suspended below and with total a vertical position and could produce noxious odors if overheated. height limits depending on factors such as roof pitch and height.See sheet 10.Galvanized steel pipe is no better than plain black or painted steel S-4. r because the galvanized zinc coating is ineffective once it has been over- 111111 Attic Insulation heated. Shield(AIS) 11. Operating the stove, heater or fireplace when the connector is red hot Attic is very dangerous.This indicates overfiring or a chimney fire. Stop firing, close the dampers, let things cool off,and keep watching for problems on G �A a nearby walls and furnishings. VA VA I 12.The slope of the horizontal portion of a connector of 1/4 inch per foot is vA Ga Maximum sometimes a building code requirement.This slope will have little effect on rl VA Insulation safety or appliance operation. If the connector is vertical, it should be Nail Flanges GA VA Height 10" installed with the crimped end down. If it can be sloped between the stove To Framing ve r'i Above Framing and chimney, use 45 degree one piece leakproof elbows (such as the \ r VA corrugated type), and try to maintain sufficient slope so that any conden- YA ve sate liquid runs back toward the appliance.To keep liquids from coming out 1 va r connector joints, the small (or crimped)end should always be down-orrtoward the stove or fireplace. CLEARANCES FOR SELKIRK CHIMNEY SYSTEM INSULATED 1 rA Ya 1.1 PIPE Chimprk ey ------ Fire Stop/Joist Shield(JS) All insulated Selkirk Chimney Systems'gas-carrying chimney parts Section are marked with important safety information confirming minimum FIG 6 FIRE STOP/JOIST SHIELD(JS)USED airspace clearance to combustibles. This minimum airspace clear- WITH ATTIC INSULATION SHIELD ance to combustibles is important in order to keep combustible mate- rials from overheating and creating a fire hazard.Never fill required If the enclosure is exterior, without penetration of the building enclosure, airspace with insulation or even non-combustible material,since such wall bands should be used to provide the necessary lateral stability. actions could cause overheating.If you are uncertain about a particu- Regardless of the benefits of the exterior enclosure, better chimney and lar installation, contact Selkirk at the number referenced at the end appliance operation will be obtained if the chimney is located entirely inside of these instructions. the heated part of the building (except of course for the part above the roof). Such parts as Fire Stops and ceiling supports are intended to be attached Enclosures of ordinary wood framing with gypsum drywall or plywood directly to the framing or to ceiling,or floors.These auxiliaries,which are in walls may be built only in one and two-family dwellings. For other types of contact with wood or other combustibles, are designed and tested to buildings, multiple occupancies or high rise construction, additional fire assure that they do not overheat at points of contact. resistance is required for enclosures as follows: A factory-built chimney that extends through any zone above that on which The instruction sheets for individual parts and the table on the back page the connected appliance is located is to be provided with an enclosure give proper framing dimensions,which in turn define the proper clearance. having a fire resistance rating equal to or greater than that of the floor or Wherever these instructions illustrate the use of a required spacer or fire roof assemblies through which it passes. stop, the purpose of the part is to maintain and assure the proper clear- ance. Even with a fire resistance rated enclosure, the use of Fire Stops at every floor level is recommended to stabilize the chimney and to retard Remember that the most important clearance requirement is that it must be possible fire spread external to the chimney. AIR SPACE. FIRESTOPPING ENCLOSURE:Interior or exterior residential chimneys should be enclosed (See Also Sheet S-2) where they extend through closets, storage areas, or habitable spaces A fire stop is any part of the building structure which prevents the spread of a where the surface of the chimney could be contacted by persons or fire or circulation of air.Where a Selkirk Chimney System is enclosed and combustible materials. The space between the enclosure and chimney framed at 2"clearance,a Firestop/Joist Shield(JS)or Fire Stop/Wall Spacer should be at least the required 2"minimum airspace clearance to combus- (WS)is the proper firestop to use at every floor.Part"JS"may be used with all tibles.(SEE SHEET S-2 FOR PROPER USE OF FIRESTOPS IN AN ENCLO- Selkirk Chimney System models. Part"WS"may be used only with Model SURE). Enclosures may be built of ordinary drywall or plywood at the SSII. required minimum of 2 INCHES AIR SPACE CLEARANCE.While properly installed firestops or supports help maintain the necessary clearances to If the enclosure or space around the chimney is larger than usual, or combustibles at ceilings or joist areas,there are no special parts to maintain irregular in shape, attach galvanized metal plates 28 gauge or heavier all clearance to inside surfaces of walls or enclosures; therefore, the builder around the edges of the Fire Stop/Joist Shield(JS)or Firestop/Wall Spacer and the chimney installer should take all necessary precautions to assure (WS)as necessary.These should be wide enough so that when installed, that this 2 inch minimum clearance or more is maintained. the gap is closed to vertical air circulation around the chimney and the pipe is securely spaced and centered. In unoccupied attics, it is very important to be sure that blown-in or other insulation does not come in contact with the chimney.A full enclosure built For firestopping to be fully effective,all ceiling and floor penetrations should in the attic should extend to the roof;however,it need only be finished well be fully framed and closed on all four vertical sides. This framing helps enough to keep insulation and stored furnishings away from the chimney. delay horizontal spread of fire and controls unnecessary horizontal air If a full enclosure is not built,an Attic Insulation Shield(AIS)MUST be used. leakage through intermediate floors. See Fig.6. CHIMNEY JOINT SECURITY A chimney enclosure is also highly recommended for any outdoor,exterior- All Selkirk chimney joints must be reinforced with either of 2 choices: mounted chimney located outside of the building wall.This enclosure can 1. Locking Bands (LB). These are furnished with pipe and elbows. be helpful in reducing internal condensation, creosote build-up and metal or deterioration. Also the enclosure, by protecting the chimney from cold 2. Stainless steel sheet metal screws(3 minimum)per joint,these are an outdoor temperatures, may improve draft and appliance operation. optional extra. At the upper end of this outdoor enclosure,the chimney should be flashed The stainless steel sheet metal screws, size #8 x 1/2" must be evenly with the flashing/storm collar termination shown in Sheet S-3. spaced around the joint and 1/2 inch above the joint separation. Before installing either the screws or the Locking Band,the joint should be II , which combine with expelled moisture to form creosote. The creosote jV. vapors condense in the relatively cool chimney flue of a slow-burning fire. e.,, G: As a result,creosote residue accumulates on the flue lining.When ignited, Enclosure— :1 + G: this creosote makes an extremely hot fire. :1 v',-2= Minimum Clearance Back-Up %, elkirk Chirr�riey With coal which can burn with a smoky fire,this smoke also condenses in Strip \ ripe r. the chimney to form soot. I� :a G: ', The chimney should be inspected at least once every 2 weeks during the i; �, heating season to determine if a creosote or soot buildup has occurred. e+ G: If creosote or soot has accumulated, it should be removed to reduce the G: risk of chimney fire. Z- 1 V, Ceiling,' (' Fire Stop/:1 r- p Creosote causes many problems. Some are visible while others are not. It ,A G; Shield(JS) 2"Minimum Clearance r� can make trouble if: *Sidewall material may be X Enclosure 1. It runs down the outside of the pipe to damage the finish on the more readily supported using Dry Wall, metal. back-up strips at upper and Plywood. Etc. 2. It drips out of joints, damaging floors or furnishings. lower ends of an enclosure. 3.It plugs up the chimney to cause poor combustion,smoking,soiling walls FIG.7 FIRE STOP/JOIST SHIELD(JS)WITH and indoor air pollution. FULL ENCLOSURE 4. It catches fire in the chimney to cause possible chimney damage and securely twist locked together.The diagram,Fig.8,illustrates these points. damage to your home. Screws or locking bands are needed to prevent accidental disengagement If you see deposits more than 1/16 inch thick,clean all of the chimney parts during chimney cleaning, and to reinforce the chimney whenever it is mechanically. This means using brushes, scraping or equivalent. Don't outdoors, along walls, or above the roof. start a chimney fire!With only slight deposits,try a hot fire to see if the black deposits change to light ash or fall down the chimney. You can hear the sound of falling deposits when temperature conditions are right. After- wards reinspect the chimney and the inside of the appliance for deposits. —Female End-Outer Wall Do not use chemical cleaners,they may corrode the inside of the chimney. They may or may not prevent or remove creosote. When they are used Use Minimum 3 Screws together with a hot fire, it is probably the fire that is doing the work. ���,_�__/r Per Joint Depending on the rate of buildup, as you learn what is going on in the I / chimney, you can adjust your cleaning schedule. Ohi, / Use 1/8^Drill Here for If you have any doubts about your ability to clean the chimney, or if the #8 x 1/2" deposits are very heavy and hard to remove, call a professional chimney FIG.8 DRILLING !, \44 Stainless Steel Screw sweep. Do not try to burn them off. DIAGRAM 000 Ii I (Close up, Cross-Section i I,j 1/2 inch It doesn't matter how careful you are with loading, fuel wood selection or of Chimney Joint) /I ,:7a draft control, you should observe the above precautions with any wood stove or chimney installation. /—Male End-Outer Wall CHIMNEY FIRES AND WHAT TO DO ABOUT THEM CAUTION: Do Not Drill Your Selkirk Chimney System is not intended or designed for use as a More Than Deep combustion or fire chamber.It is very easy to over fire yourwoodbumingappliance with kindling,scrap lumber,brush or any fast burning fuel.This can produce flames and high temperatures all the way up the chimney,and may cause chimney damage. Warning:The chimney pipe and its fittings must be assembled with metal-to- If you see your appliance or the smoke pipe glowingred, you are risking metal joints as furnished.Do not use tape or any sealing compound(such as pp p p tar, mastic, putty or silicone)at the outer joints. Sealers in the joints may chimney damage,or a fire.The creosote may be burning inside the chim- cause the insulation to accumulate moisture and will cause corrosion or freez- ney.If you see flames coming out the top,you are either overfiring or there ing failures. is a chimney fire. CAUTION:DO NOT USE SELKIRK CHIMNEY SYSTEM PIPE WITH DAM- If the fire in your heater has gotten out of control, or if you suspect a AGED ENDS chimney fire for any reason, follow these steps: Both the inner and outer pipe must join properly to avoid leakage and accidental disengagement. Slight eccentricity of the inner pipe will not 1. Immediately close all dampers and/or air entrance openings to your affect operation provided that the joint goes together completely. Minor appliance.This includes doors on Franklin type stoves.Block off fireplace dents or irregularity of the outer pipe will not have any perceptible effect on openings. temperature safety. 2.Alert your family to the possible danger. CHIMNEY OPERATION AND MAINTENANCE 3. Inspect your appliance and chimney surroundings for possible fire. If in The need for chimney maintenance depends on the kind of appliance and doubt, alert your fire department. 4. Do not continue to use your appliance until it and your chimney have how it is operated.Gas and oil-burning appliances may need very little,but been thoroughly inspected.Overheating can cause metal parts to expand, wood and coal-burning appliances may need a great deal of chimney buckle and crack. If you are not certain, have a qualified heating person maintenance.Open front fireplaces without doors usually dilute their smoke disassemble all parts so they can be inspected and replaced. with large amounts of air.Thus the buildup of chimney deposits is generally 5. Do not use salt or water on the fire in your appliance'. Salt is corrosive very low. "Air tight" or controlled draft wood stoves and heaters produce and water will cause a dangerous steam explosion.Yot� might be able to dense smoke if they are loaded for long duration or overnight fires,and can control the fire by using ashes, sand or baking soda, sir{ce baking soda is rapidly produce heavy,thick creosote deposits. It is possible, by having a an ingredient used for dry chemical fire extinguishers. short duration daily hot fire,to burn off these deposits or prevent them from 6.After a chimney fire, when it is safe to do so, check internal locations building up to dangerous levels.This takes skillful operation and an appre- such as the attic and under the roof and keep watching for two or three ciation of how to get the correct temperature. hours.There may be delayed smoldering and subsequent ignition,even if CREOSOTE AND SOOT FORMATION AND NEED FOR REMOVAL the fire inside the chimney has been controlled. When wood is burned slowly, it produces tar and other organic vapors, II FRAMING DIMENSIONS FOR SELKIRK CHIMNEY SYSTEMS TO MAINTAIN 2 INCH AIR SPACE CLEARANCE CHIMNEY SIZE:(Inside Diam.) 5" 6" 7" 8" 10" 12" 14" TYPE HT TYPE HT TYPE HT TYPE HT TYPE HT TYPE HT TYPE HT CEILING OR FINISH SUPPORT` 11-1/4"X11-1/4" 12-1/4"X12-1/4"" 13-1/4"X13-1/4"" 14-1/4"X14-1/4" 16-1/4"X16-1/4" 18-1/4"X18-1/4" 20-1/4"X20-1/4" CEILING PENETRATIONS" 11"X 11" 12"X 12" 13"X 13" 14"X 14" 16"X 16" 18"X 18" 20"X 20" FLOOR OPENINGS' 44 44 44 « ROOF OPENINGS' •• 64 °° `° 44 44 WALL OPENINGS' « « « « L< « l{ All framing dimensions may be up to 1/2"more,but not less than the above values.Check support dimensions before using. MAXIMUM HEIGHT(OR LENGTH)OF CHIMNEY FOR SUPPORTS SIZE 5", 6", 7", 8" 10", 12", 14" OF SUPPORT TYPE PART NO. FH FEET CHIMNEY CHIMNEY ANCHOR PLATE AP 85 85 FINISH OR CEILING SUPPORT FSP,CSP 50 50 INSULATED TEE IT 50 40 WALL SUPPORT KIT WSK 50 40 ROOF SUPPORT(A) RSP 30 30 INTERIOR RESUPPORT IR 18 18 SUPPORT BOX SB 20 — NOTE: (A) 20 feet of chimney may be suspended below a roof support with all joints securely threaded, using locking bands or screws CHIMNEY PIPE LENGTH SELECTOR CHART Pipe Length 6 9 12 18 24 36 48 Pipe Length 6 9 12 18 24 36 48 Total Installed Height 43/4 73/4 103/4 161/4 223/4 343/4 461/4 Total Installed Height 44'a 73 103 163/ 223/a 344'a 46�/a Ft. In. Inches NUMBER OF CHIMNEY PIPE SECTIONS Ft. I n. Inches NUMBER OF CHIMNEY PIPE SECTIONS —43/4 43/4 1 9 21/4 1101/4 1 2 —7 3/4 73/4 1 9 81/4 1161/4 1 2 —103/4 103/4 1 10 81/4 1281/4 1 2 1 1/2 121/2 1 1 9 7 115 1 3 1 43/4 16 3/4 1 10 1 121 1 3 1 61/2 181/2 1 1 10 7 127 1 3 1 10 3/4 22 3/4 1 11 81/4 140 1/4 3 1 111/4 231/4 1 1 1 12 7 151 1 3 2 10 3/4 34 3/4 1 13 1 157 1 3 2 111/4 351/4 1 1 1 13 7 163 1 3 3 31/2 391/2 1 1 14 7 175 1 3 3 61/2 421/2 1 1 11 7 139 4 3 91/2 451/2 1 1 12 11 3/4 1553/4 1 4 3 10 3/4 463/4 1 13 5 3/4 161 3/4 1 4 4 21/4 501/4 1 1 1 15 7 187 4 4 31/2 511/2 1 1 16 11 3/4 2033/4 1 4 4 3 1/2 511/2 1 1 17 5 3/4 209 3/4 1 4 4 61/2 541/2 1 1 18 5 3/4 221 3/4 1 4 4 91/2 571/2 1 1 14 53/4 173 3/4 5 5 31/2 631/2 1 1 16 4 1/2 196 1/2 1 5 5 91/2 691/2 1 1 19 5 3/4 233 3/4 5 5 91/2 691/2 2 21 41/2 2561/2 1 5 6 91/2 811/2 1 1 22 41/2 2681/2 1 5 7 21/4 861/4 1 2 17 41/2 2081/2 6 7 81/4 921/4 1 2 19 31/4 231 1/4 1 6 7 81/4 921/4 1 2 23 41/2 2801/2 6 7 91/2 931/2 2 25 31/4 3031/4 1 6 8 81/4 1041/4 1 2 26 31/4 3151/4 1 6 0015110-0712