31B-003 (10) BP- 022-1422 66 BANCROFT RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 31B-003-001 CITY OF NORTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-1422 PERMISSION IS HEREBY GRANT D TO: Project# WOOD INSERT Contractor: License: Est. Cost: DOUGLAS L'ABBEE CSL99401 Const.Class: Exp.Date: 01/06/2024 WELCH JAMES ROBERT & LUCY EL ZABETH Use Group: Owner: MODAHI Lot Size (sq.ft.) Zoning: URA Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: 100 STATE RD (413)397-3463 01400503301116 WHATLEY, MA 01093 ISSUED ON: 11/02/2022 TO PERFORM THE FOLLOWING WORK: WOOD INSERT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIO I ATION OF ANY OF ITS RULES AND REGULATIONS. Signature: 55.-}9T SC1 Fees Paid: $40.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Office of the Building Commissioner City of Northampton SH M r, 7 jo, ,�, "-EN s.�Q- Sf " ' Massachusetts ' /Q/�/� �wS �!t w ` IC DEPARTMENT OF BUILDING INSPE TIONS �/ a'. �' "' kk f` 212 Main Street • Municipal Bµ�ild' g � ` �;, `a :.; +'`�.' Northampton, MA /olo6al ®'' ss.• ` ��-: IOV • ,;,gin °frf,,,; APPLICATION FOR SOLID FUEL APPLIANCE 114 LATION o,0600ys Property Information Owners Name: j,rnt,3 A.,,/e-/ch Address: ‘G /3,nero/ /?) rfVvenr09 /r) o/dB (No.) (Street Address) Phone: 1-//3 S 574,7 Cell: Email: Owners Signature: )\\‘ ti Date: 4,6, l Contractor's Information (If Applicable) Name: 7)avq4J' I Ahbc lAr 44e %cc. Phone: V/1 3 Q-7 3V6� Construction Supervisor's License #: '7s/aY Expiration: /-‘'a9 Home Impr. Contractor License #: /la V 77 Expiration: //-ifs / Stove Information Type of Fuel (check all that apply): Wood V Pellet Coal Location: Freestanding Insert Y Manufacturer: ?ice ,l'c t 4e-rgy Model: itisf ez.. insrcf -LI— /nS/'t/iit7 !✓' C/cY SS' /inc.,- /nfa 717C/C -FOR BUILDING DEPARTMENT USE ONLY----------____________—_ Permit# 6,- ; -/z-/,)2. Date Applied: /1- i-7_c��Z Total all Fees: $ le */35'33 Building Official: 400J /boy, Date Issued: 11- Z-?. ZZ Print Signature of Building Official: _ a..v ♦.r..rr.r.S.fed. lJ 1/.....vu V"...wvv..., ^_; Department of Industrial Accidents t'f,' •. _ t•t,_•':. Office of Investigations I:�--I t^ t- Lafayette City Center ^;L'; ' 2 Avenue de Lafayette, Boston,MA 02111-1750 ,.,,.., WWW.ntass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers pplicant Information Please Print Legibly game (Business/Organization/individual):THE FIRE PLACE \.ddress:100 STATE ROAD :ity/State/Zip:WHATELY, MA 01093 Phone#:413-397-3463 re you an employer? Check the appropriate box: Type of project(required): E] I am a employer with 10 4. ❑ I am a general contractor and I 6 ❑Men construction employees (full and/or part-time).* have hired the sub-contractors ❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' y ❑ Building addition [No workers' comp.insurance comp. insurance_t ❑ We are a corpo ration�. and its 10.0 Electrical repairs or additions ❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself' [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.] '' c. 152, §1(4),and we have no employees. [No workers' 13.E Other comp. insurance required.] ty applicant that checks box ill must also fill out the section below showing their workers'compensation policy information. omeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. intractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have doyces. If the sub-contractors have employees,they must provide their workers'comp.policy number. in an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site 'or'm ation. nuance Company Name:MA RETAIL MERCHANTS WC GROUP 1NC Hey#or Self-ins. Lie. #:01400503301116 Expiration Date:1-1 .23 b Site Address: GG &on grail- RO City/State/Zip: . /v or 4 sunfr4 At,14 :tack a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). ilure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a ie up to S 1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a tine up to S250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of vestigations of the DIA for insurance coverage verification. in hereby certif i2und 'the pains any p,�-� naahties ofperjruy that the information provided above is true and correct. anuturc: _ 1� / Date: ,i0'.75/--'1. ionc#; 413-397-3463 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): l❑Board of Health 20 Building Department 310City/Town Clerk 4.1:Electrical Inspector 59Plumbing Inspector 6.0Other Contact Person: Phone#: Safety Clearances READ ALL INSTRUCTIONS BEFORE INSTALLING Masonry or Factory Built Fireplace AND USING THIS APPLIANCE.FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY The minimum required clearances to surrounding DAMAGE, BODILY INJURY, OR EVEN DEATH. combustible materials when installed into a masonry or factory built fireplace are listed below and in Fig.#1. We strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequently.This Minimum Clearances to Combustibles may be due to curing of stove paint or fumes caused by (Measured From Insert Body) accidentally leaving the fire door open. Do not discon- nect the detectors.If necessary, relocate them to reduce Adjacent Sidewall 9 in. (229 mm.) their sensitivity. Mantel 29.5 in. (749 mm.) With Mantel Shield 18.5 in. (470 mm.) SAFETY NOTICE:If this stove is not properly installed,a Top Facing 29.5 in. (749 mm.) house fire may result. For your safety,follow the installa- With Mantel Shield 18.5 in. (470 mm.) tion directions.Consult local building or fire officials about Side Facing 9 in. (229 mm.) restrictions and installation inspection requirements in your area. The services of competent installer, certified by the Wood Energy Technical program (WETT) - in Canada, Hearth Education Foundation (HEARTH) - in U.S.A. (or equivalent) are strongly recommended. Dimensions 36 5/8 2 7/8� — #42 5/8 23 1/8 6 1/4 0 2630 9 3/4 19 3/4 O 18 5/16 I � - Py ._ • �Il_rl IV' r. —20 1/2 —14 7/8— 6 3/8 *Oversized Surround —22 1/2 21 1/4 Fig. # 1 Mantel or Top Facing I I I I I 1 I I I I J -- I 2s 1/2" I I I H— i 18 1/2°with mantel shield 1 I I l l 1 - c 1 47 3/4" 9Ce�t I ) j- 6 1 I 36 3/4"with mantel shield dl I 4 ' A�eii 9„ ^ ` r -;\ 1 - 1 l - _cn1 I — _ 1 I I 8" 41)11Hrthea 16" T 081112-24 VISTA INSERT-C i 3 Maintenance Checks Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (See website for descriptions and more detail) Weekly: - Firebrick - Visual, for cracking. - Door Gasket - sagging, placement, damage. Monthly - Brick rail tabs and brick rails. - Air riser tube in the back of the firebox. - Back side of airwash chamber. - Baffle locking pin. - Boost tube cover. When Cleaning the Chimney System: - Top baffle board/blanket. - Baffle. - Top heat shield and mounting bolt. - Baffle Gasket. - Brick Rails. - Manifold. Blower: -The blower should be cleaned out a minimum every six months by using a vacumn on the grill openings in the back and bottom of the blower casing to remove any dust and debris. - Some warping of the baffle is normal(up to 1/4" or .65cm). - Replace if the baffle has permanent warping greater than this or has cracking or breakage. - Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty 4 VISTA INSERT-C 081112-24 *Fireplace hearth requirements: (Measured without the insert) The hearth may be flush with or raised above an adjacent combustible floor and must extend 16"in front and 8"beyond each side of the fireplace opening. MINIMUM FIREPLACE it ii OPENING AND HEARTH i um1. • DIMENSIONS 1 • ,��� • i ■lll..• - .. J � ■al j -=. Fi .. __ �1I•r 111 1... __I ■i , ,16"�i �7OI.■. ■NI ■ 1 ,�■ N ■ F 18" ..�I Non-combustible fi eplaceII • - hearth asommil 2 *AAMMIIMILISA Z llllllllllllll. aTrai 1111. 111 2" ** Ember protection: Combustible floor in front of the fireplace insert must be protected from hot embers by non-combustible material extend- ing 16"(USA) and 18"(CANADA) to the firing side and 8"to other sides of the unit. Consult CAN/CSA-B365 Installation Code for Solid-Fuel-Burning appliances and equipment in Canada, and N.FP.A. 211 Standard for chimneys, fireplaces, vents and Solid-Fuel-Burning appliances in USA. 0 r= MINIMUM EMBER \ . . PROTECTION ' Aii ' - - = lb an DIMENSIONS • f 231/2"�� `�:�0 MN •,�;c ** c Mi- Non-combustible hearth '' 16"USAF — 1I 18"CANADA 1( Non-combustible floor gc. i If covering -------------- ►. t2„ 081112-24 VISTA INSERT-C 5 Installation Fig.#4 Full Flue Liner Your Insert is designed to be installed into a masonry or factory built zero-clearance fireplace. The masonry i `' fireplace must be built according to the requirements of Rain Cap the Standard of Chimneys,Fireplaces,Vents and Solid 'Fuel Burning appliances,N.F.P.A.211 (Latest Edition) or applicable National, Provincial, State or local codes. — The installation shall conform to CAN/CSA-B365,Instal- lation Code for Solid-Fuel-Burning Appliances and Equipment. The factory built zero-clearance fireplace Stainless Steel and its chimney must be listed per UL 127 or ULC S610 Rigid or Flex Liner ir _ - standards.Warning: Under no circumstances is this heater to be installed in a makeshift or"temporary" manner. — DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE Mantel or Top Facing N . � SERVICING ANOTHER APPLIANCE. _ Fireplace Specifications 9 Your fireplace is required to have the following minimum iJ \ sizes: ;�� mim WIDTH 23-1/2" (597 mm) • . • • HEIGHT 19-7/8" (505 mm) -- DEPTH 15" (381 mm) Mil Chimney height 15' (minimum). ` gI • A metal tag is provided and is to be fastened to the jl back wall of the fireplace, if the fireplace has been modified to accommodate the insert. The Insert must be installed in accordance with local Into a Masonry Fireplace and or national building codes. The two methods of flue Inspect your fireplace for cracks, loose mortar or other connection that are acceptable in most areas are: physical defects. If repairs are required, they should be Full Flue Liner: where a listed stainless steel rigid or completed before installing your insert. flexible liner extends from the Insert flue collar to the top The fireplace chimney must be suitable for wood burning of the chimney. use. Check for creosote build up or other obstructions, Direct Flue Connection: where a listed stainless steel especially if it has not been in use for some time. rigid or flexible liner extends from the Insert flue collar to The existing fireplace damper is to be locked open or the first chimney flue liner. removed completely. Note: A clean-out door may be required under local codes, when a direct flue connection is used. Consult WARNING: Do not remove bricks or mortar from your local codes. existing fireplace. Pacific Energy highly recommends the use of a full Exception: Masonry or steel, including the damper liner as the safest installation and providing opti- plate, may be removed from the smoke shelf and ad- mum performance. When connected to a full liner, jacent damper frame if necessary to accommodate a the Insert is able to draft correctly and will prevent chimney liner,provided that their removal will not weaken problems such as difficult start-ups and smoking the structure of the fireplace and chimney, and will not out the door. reduce protection for combustible materials to less than that required by the National Building Code. 6 VISTA INSERT-C 081112-24 Full Flue Liner -(Required in Canada) Direct Flue Connection Fig.# 7 1) Measure the chimney height from the top of the exist- ing flue to the floor of the hearth. This will allow extra Mantel or length of liner for flashing and rain cap. Top Facing .- Chimney 2) Feed the stainless steel liner from top of the chimney, m m Flue Liner through the damper area and into the fireplace cav- \ ma- lty. ` i 3) Attach a stove connector to the bottom of the liner. i��i/,l.m■mmi i_ilmi 4) Push the Insert into position inside the fireplace and m1M111 MEMattach the connector to the stove collar. Use the rear 6°Stainless Steel MEI l Rigid or Flex Liner �" ` i ill adjusting legs to level the Insert. 9' ��r ���� i�il� Note: For better access, the top of the casing may be re Q#'III MIIM removed (Fig.#4). If it is necessary to get access to the I— connector pipe through the flue outlet of the Insert, the •Z baffle can be removed (see Baffle Removal section). 5) Measure,trim and shape a top flashing to fit the exist- t • ing chimney flue. Plan for a 1"to 1-1/2"overlap on each side. Place flashing over top of the liner and 1^li seat firmly against the tile. 6) Screw flashing collar to liner. Caulk gap around flash- O ing with RTV silicone. .......I . 7) Attach a rain cap to the end of the liner. A storm collar may be used if desired. Consult your local Dealer about relining your fireplace Into a Factory Built Fireplace chimney. Your Insert may be installed into a factory built fireplace Direct Flue Connection - (USA only) (size permitting) with the following requirements: 1) Measure from the first chimney flue liner to the top 1) Inspect your fireplace for damage or other physical of the Insert. Allow extra length of liner to insert into defects.The fireplace must be in good working condi- flue tile. tion. If in doubt about its condition,seek professional 2) Feed the stainless steel liner through the damper advice. Check for creosote build up or other obstruc- area and into the first chimney flue tile. Seal around tions inside the chimney, especially if it has not been pipe. in use for some time. Before installing, clean your Note: A clean-out door may be required under local chimney system thoroughly. codes, when a direct flue connection is used. Consult 2) A full stainless steel rigid or flexible flue liner meeting local codes. type HT requirements (2100°F) per 1777 (U.S.) or 3) Push the Insert into position inside the fireplace and U LC S635(Canada)must be used for both safety and attach the connector pipe to the stove collar. Use the rear adjusting legs to level the Insert. performance. The liner must be securely attached to Note: For better access, the top of the casing may be the Insert flue collar and the chimney top. removed (Fig.#6). If it is necessary to get access to the 3) The surround must be sealed to the fireplace front connector pipe through the flue outlet of the Insert, the or the damper area around the chimney liner must baffle can be removed (see Baffle Removal section). be sealed to prevent room air entering the chimney cavity of the fireplace. 4) The air flow within and around the fireplace must Fig.#6 not be altered by the installation of the Insert(i.e.no blockage of louvers or cooling air inlet or outlet ports). This includes the circulating air chambers in a steel ii, „ fireplace or metal heat circulator. ' N\ 5) Alteration of the fireplace in any manner is not permit- ted with the following exceptions: a: external trim pieces which do not affect the opera- IL. ‘ ; tion of the fireplace may be removed and stored on or within the fireplace for re-assembly if the Insert is / '' ' '''' removed. b: the chimney damper may be removed to install the liner. 081112-24 VISTA INSERT-C 7