202133 - Noho Social Coffee Shop & Speakeasy_Full Set 9.24.21c 2018 CAOLO & BIENIEK ASSOCIATES, INC.
ISSUE DATE:
521 East Street
Chicopee, Massachusetts
CAOLO & BIENIEK ASSOCIATES, INC.
ARCHITECTURE · PLANNING · INTERIOR DESIGN
1.413.594.2800
www.cbaarchitects.net
PROJECT NO:
CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS:
Noho Social Coffee Shop & Speakeasy
PROGRESS SET
SEPTEMBER 24, 2021
202133
261 KING ST, NORTHAMPTON, MA
Sheet List
Sheet Number Sheet Name
GENERAL
A-000.00 COVER SHEET
ARCHITECTURAL
D-100.00 DEMOLITION
A-100.00 FLOOR PLAN
A-700.00 FINISHES
A-900.00 REFLECTED CEILING PLAN
MEP
FS1.10 EQUIPMENT & SCHEDULE
FS1.20 PLUMBING ROUGH IN PLAN
FS1.30 ELECTRIC ROUGH-IN PLAN
FS1.40 SPECIAL CONDITIONS PLAN
FS1.50 FLOOR PLAN - LIGHTING CONTROLS
FS1.51 EQUIPMENT ELEVATION
LOCATION KEY PLAN
261 KING STREET
NORTHAMPTON, MA
SINGER EQUIPMENT COMPANY
FOOD SERVICE
180 HELLER PLACE
BELLMAWR, NJ 08030 856-559-4200
WH
EXISTING CONSTRUCTION - TO BE DEMOLISHED
EXISTING DOOR & FRAME - TO BE REMOVED
EXISTING CONSTRUCTION TO REMAIN.
DEMOLITION LEGEND
1. CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER ANY AND ALL DISCREPANCIES TO
THE PROPOSED DEMOLITION PRIOR TO EXECUTION OF THE ITEMS IN QUESTION.
2.THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL AREAS NOT INCLUDED IN THIS
WORK.
3.ALL DEMOLISHED MATERIAL SHALL BE LEGALLY DISPOSED OF BY G.C.
5.GENERAL CONTRACTOR SHALL FIELD MEASURE TO COMPLETE DEMOLITION ACCURATELY.
6.CONTRACTOR SHALL MAINTAIN A REQUIRED FIRE EXTINGUISHER AS REQUIRED BY CODE IN
VACANT SPACE
7.SEE PROPOSED STRUCTURAL/ELECTRICAL/MECHANICAL/PLUBMING DRAWINGS FOR
REPLACEMENT OF ANY EXISTING ITEMS NOT LISTED IN THE GENERAL DEMOLITION NOTES
8.ROOF TO REMAIN. ALL EXISTING ROOF PENETRATIONS TO BE REMOVED - PATCH ROOF AS NEEDED.
9.NO HAZARDOUS MATERIAL ARE KNOWN TO BE PRESENT IN BUILDING. CONTRACTORS SHOULD
NOTIFY OWNER IF ANY SUSPECT MATERIALS ARE ENCOUNTERED PRIOR TO REMOVAL.
DEMOLITION GENERAL NOTES
1
1
1
2
3
4
5
6
3
2
TIE INTO EX'G.
SANITARY LINE
(REPAIR FLOOR
FINISHES)
AREA OF WORK
SCALE:
PROJECT NO:
c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED
PROJECT MANAGER:
PROJECT ARCHITECT:
PRODUCTION LEADER:
PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE:
THIS DRAWING IS THE PROPERTY OF CAOLO &
BIENIEK ASSOCIATES, INC. THE RE-USE OR
REPRODUCTION OF THIS DRAWING FOR ANY
PURPOSE WHATSOEVER WITHOUT AN
EXPRESSED WRITTEN AGREEMENT BETWEEN
CAOLO & BIENIEK ASSOCIATES INC. AND THE
USER IS STRICTLY PROHIBITED. RIGHTS TO
USE THE INFORMATION ON THIS SHEET ARE
NOT TRANSFERRED UNTIL PAYMENT HAS
BEEN RECEIVED FOR SERVICES RENDERED.
ANY RIGHTS SO GRANTED ARE NON-
TRANSFERABLE TO OTHER PARTIES WITHOUT
THE PRIOR EXPRESSED WRITTEN CONSENT OF
CAOLO & BIENIEK ASSOCIATES, INC.
A
1
B
C
D
E
F
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
D-100.00
202133DEMOLITIONNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX
MRRJH
CE
DEMOLITION KEYED NOTES
NUMBER DESCRIPTION
1 SAW-CUT CONCRETE SLAB AND EXCAVATE AS REQUIRED TO
INSTALL NEW PLUMBING, SEE PLUMBING DWGS.
2 REMOVE ALL CARPET TILE, STACK FOR RELOCATION (BY
OTHERS) TO STORAGE FOR FUTURE USE.
3 REMOVE ALL CEILING TILES AND STACK/CRATE FOR
RELOCATION (BY OTHERS)
4 REMOVE HVAC GRILLS, SALVAGE FOR REINSTALLATION AND
PAINT TO MATCH NEW CEILING COLOR (TBD)
5 REMOVE SPINKLER COVERS AND REPLACE WITH NEW
COVERS TO MATCH NEW CEILING TILE ( COLOR TBD)
6 ELECTRICAN TO REMOVE ALL 2X2 LIGHTING IN PUBLIC AREA (
LEAVE IN KITCHEN AREA), STACK W/ PROTECTION FOR
RELOCATION (BY OTHERS)
1/4" = 1'-0"D-100.00
G4 TENANT DEMOLITION FLOOR PLAN DATEDESCRIPTION
WH
5' - 10"9' - 8"6' - 5"B7
A-100.00
B7
A-100.00
B7
A-100.00
LINE OF EXIST'G SOFFIT ABOVE
102
1547 SF
101
COFFEE
SHOP &
SPEAKEASY
274 SF
102
KITCHEN
53 SF
103
T.R.
53 SF
104
T.R.
101B
100
103
104
ENCLOSE COLUMN
W/ GYP. BOARD
NEW. ALUM. &
GLASS WALL, SIM.
TO ENTRY
B5
A-100.00
NOTE: KITCHEN EQUIPMENT
SHOWN FOR REFERENCE. SEE
KITCHEN PLANS FOR MORE
INFORMATION.
FD
FD
J-MOLD, TYP.
EXIST'G
GRID
NEW, CLEANABLE
ACOUSTICAL CEILING
TILES
FRP
5/8" GWB
WOOD
BLOCKING
EXIST'G
GRID
NEW SUSP.
ACOUSTICAL TILE
CLG.
6" STEEL STUDS @ 16" O.C.,
FILL CAVITY WITH INSULATION KITCHEN
N
FLUSH W/
TEMPERED GLAZING
GENERAL NOTE:
1. PROVIDE APPROPRIATE RATED GLAZING ON ALL
DOORS WHERE INDICATED ON THE DOOR AND
FRAME SCHEDULE.
VARIES
VARIES SEE DR. SCHEDULE8"6"
FR-1 DOOR HEIGHT2"2"2"
SEE DR. SCH. FOR SIZES
DOOR AND FRAME SCHEDULE TERMS & ABBREVIATIONS:
SOLID CORE WOOD
ALUMINUM
HOLLOW METAL
GALVANIZED HOLLOW METAL
INSULATED GALVANIZED HOLLOW METAL
PREFINISHED
OVERHEAD DOOR
OVERHEAD DOOR W/ GLAZING
COILING DOOR
HOUR
HARDWARE
DUAL EGRESS
ELECTRIC DOOR STRIKE
CARD READER
KEYBOARD
DOOR RELEASE
HOUR
TEMPERED
SCW
ALUM
H.M.
G.H.M.
I.G.H.M.
PREFIN.
O.H.
O.H.G.
CD
HR.
H.W.
D.E.
E.D.S.
C.R.
KY
D.R.
HR
TEMP
3' - 8"16 GA. HOLLOW METAL KD
FRAME - INTERIOR
C7
A-100.00
E7
A-100.008"VARIESSEE WALL TYPES
VARIES
DOUBLE 20 GA. MTL STUD W/
NESTED CONTINUOUS 2X WD
BLOCKING.
JAMB ANCHOR. (TYP.)
HM DOOR FRAME. SEE
SCHEDULE.
SILENCERS. REFER
TO SCHEDULE.
DOOR. REFER TO
SCHEDULE.5/8"2"1/2"
SEE WALL TYPES
VARIES
DOUBLE 20 GA. MTL STUD
W/ NESTED CONTINUOUS
2X WD BLOCKING.
JAMB ANCHOR. (TYP.)
HM DOOR FRAME.
SEE SCHEDULE.
SILENCERS. REFER
TO SCHEDULE.
DOOR. REFER TO
SCHEDULE.5/8"2"1/2"4"DISTANCE FROM DOOR
EDGE TO FACE OF
PERPENDICULAR WALL.
WHERE APPLICABLE.
DOOR HARDWARE
A.DOUBLE ACTION
• (3) DOUBLE-ACTION AUTO-
CLOSING HINGES
• KICKPLATE (BOTH SIDES)
• PUSH PLATES BOTH SIDES
• WALL/FLOOR STOP
V.I.F.V.I.F.MATCH EX'GV.I.F.MATCH EX'GOF GRIDTO UNDERSIDEV.I.F.
MATCH EX'G
CLEAR
ANONDIZED
FRAMING
CLEAR
GLAZING
FROSTED
GLAZING,
SIMILAR TO
TLC.
DUPLEX / DATA COMBINATION RECEPTACLE LOCATIONS IN
CONTRACT. ( PROVIDE GFCI IN WET AREAS) VERIFY MOUNTING
HEIGHTS AND FINAL LOCATIONS W/ OWNER
ELECTRICAL SYMBOLS LEGEND
SCALE:
PROJECT NO:
c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED
PROJECT MANAGER:
PROJECT ARCHITECT:
PRODUCTION LEADER:
PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE:
THIS DRAWING IS THE PROPERTY OF CAOLO &
BIENIEK ASSOCIATES, INC. THE RE-USE OR
REPRODUCTION OF THIS DRAWING FOR ANY
PURPOSE WHATSOEVER WITHOUT AN
EXPRESSED WRITTEN AGREEMENT BETWEEN
CAOLO & BIENIEK ASSOCIATES INC. AND THE
USER IS STRICTLY PROHIBITED. RIGHTS TO
USE THE INFORMATION ON THIS SHEET ARE
NOT TRANSFERRED UNTIL PAYMENT HAS
BEEN RECEIVED FOR SERVICES RENDERED.
ANY RIGHTS SO GRANTED ARE NON-
TRANSFERABLE TO OTHER PARTIES WITHOUT
THE PRIOR EXPRESSED WRITTEN CONSENT OF
CAOLO & BIENIEK ASSOCIATES, INC.
A
1
B
C
D
E
F
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A-100.00
202133FLOOR PLANNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX
MRRJH
CE
1/4" = 1'-0"A-100.00
F1 FLOOR PLAN
1 1/2" = 1'-0"A-100.00
B7 KITCHEN WALL TYPE
DOOR SCHEDULE
DOOR # DOOR STYLE WIDTH HEIGHT THICKNESS
DOOR
MATERIAL DOOR FINISH GLAZING TYPE FRAME TYPE FRAME MATL.
FRAME
FINISH FIRE RATING HARDWARE COMMENTS
100 FG 3' - 0" 7' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN
101B F 3' - 0" 7' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN
102 N 3' - 0" 7' - 0" 1 3/4" HM PNT. TEMP. FR-1 HM PNT. NA A DOUBLE ACTION DOOR W/ VISION PANEL AND PUSH PLATES
103 F 3' - 0" 8' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN
104 F 3' - 0" 8' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN
3" = 1'-0"A-100.00
C7 TYP. DOOR HEAD DETAIL
3" = 1'-0"A-100.00
E7 TYP. DOOR JAMB DETAIL
1/4" = 1'-0"A-100.00
B5 INTERIOR STOREFRONT ELEVATION
COORDINATE NUMBER
AND LOCATION OF NEW
ELECT. / DATA RECEPTACLES
WITH OWNER.
EXISTING RECEPTACLES TO BE
REPLACES WITH NEW TYPE.
PROVIDE BLOCKING AS
NEEDED FOR WALL MOUNTED
EQUIPMENT. COORDINATE W/
KITCHEN PLANS.DATEDESCRIPTION
WH
RESILIENT
FLOORING OVER
CONCRETE.
CARPET OVER
CONCRETE.
REDUCER STRIP,
CONFIRM PROFILE DURING
SUBMITTAL PROCESS.
DOOR. REFER TO DOOR
SCHEDULES FOR
ADDITIONAL INFO.
NOTE: WHERE REQUIRED,
TRANSITION STRIPS SHALL BE
CENTERED ON CENTERLINE OF
DOOR IN THE CLOSED POSITION.
102
1547 SF
101
COFFEE
SHOP &
SPEAKEASY
274 SF
102
KITCHEN
53 SF
103
T.R.
53 SF
104
T.R.
101B
100
103
104
B5
A-100.00
NOTE: KITCHEN EQUIPMENT
SHOWN FOR REFERENCE. SEE
KITCHEN PLANS FOR MORE
INFORMATION.28' - 7 1/4"28' - 0"19' - 7"15' - 5 1/2"8' - 7"
5' - 10"
12' - 9 1/4"12' - 7"
CPT TILE
LVT
LVT
E7
A-700.00
E7
A-700.00
E7
A-700.00
3' - 0"E5
A-700.00
CLG. CEILING
CONC CONCRETE
CPT CARPET TILE
EX'G EXISTING
FRP FIBER REINFORCED PLASTIC
GWB GYPSUM WALL BOARD
PNT PAINT
VCT VINYL COMPOSITE TILE
WC WALL COVERING
FINISHES ABBREVIATION KEY
5MM LVT
FLOORING OVER
CONCRETE.
CARPET OVER
CONCRETE.
NOTE: WHERE REQUIRED,
TRANSITION STRIPS SHALL BE
CENTERED ON CENTERLINE OF
DOOR IN THE CLOSED POSITION.
METAL EDGE STRIP
FLUSH WITH LVT AND CARPET,
SCHLUTER VINPRO-S OR EQ.
FINISH LEGEND
CODE DESCRIPTION MANUFACTURER STYLE COLOR COMMENTS
CPT CARPET TILE 24" X 24" J&J FLOORING APERTURE II 7770 3106 NOISE INSTALL. METHOD TBD
LVT LUXURY VINYL TILE 23.62" X 23.62" PATCRAFT 1313V CHARTERED 00590 ASTERICKS 20 MIL WEAR LAYER
VSB 4"H VINYL STRAIGHT BASE TBD
TRN FLOORING TRANSITION SCHLUTER L-ANGLE STRIP UNDERLAYMENT FLASHING TO LEVEL
WC-1 WALLCOVERING WOLF GORDON HAVEN III ANTOINETTE SILK ALK 7-7550 CRIMSON SEATING AREA SIDE OF KITCHEN WALL AND WALL TBD
WC-2 WALLCOVERING WOLF GORDON BALLARI MYLAR / STARDUST GOH 31885552 REVERSE HANG / RANDOM MATCH
WC-3 WALLCOVERING WOLF GORDON THEORBO TBD STRAIGHT HANG / STRAIGHT MATCH
WC-4 WALLCOVERING WOLF GORDON THEORBO TBD STRAIGHT HANG / STRAIGHT MATCH
P-1 WALL PAINT TBD TBD LINEN FINISH
P-2 WALL PAINT TBD TBD LINEN FINISH
ACT ACOUSTICAL CEILING TILE TBD REPLACEMENT CEILING TILE
GRID PNT ELECTROSTATIC PAINT TBD PAINT FOR EXISTING CEILING GRID
BAR FINISHES
COUNTERTOPS CAMBRIA OPTION 1: DELGATIE LUXURY SERIES +/- 2" THICK. STOOL SIDE EDGE EASED, OTHER EDGES SQUARE
OPTION 2: BRITTANICCA WARM LUXURY SERIES
BAR FRONT (VISIBLE AREA) FORMICA DECOMETAL M9424 COPPER PATINA
BAR REAR (NON-VISIBLE FACE) TBD (POSSIBLY FORMICA BLACK RECYCLE KRAFT COORDINATE W/ EQUIPMENT PROVIDER
MATT 9685-58 OR CHOCKOLATE WARP MATT 5881-58)
SCALE:
PROJECT NO:
c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED
PROJECT MANAGER:
PROJECT ARCHITECT:
PRODUCTION LEADER:
PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE:
THIS DRAWING IS THE PROPERTY OF CAOLO &
BIENIEK ASSOCIATES, INC. THE RE-USE OR
REPRODUCTION OF THIS DRAWING FOR ANY
PURPOSE WHATSOEVER WITHOUT AN
EXPRESSED WRITTEN AGREEMENT BETWEEN
CAOLO & BIENIEK ASSOCIATES INC. AND THE
USER IS STRICTLY PROHIBITED. RIGHTS TO
USE THE INFORMATION ON THIS SHEET ARE
NOT TRANSFERRED UNTIL PAYMENT HAS
BEEN RECEIVED FOR SERVICES RENDERED.
ANY RIGHTS SO GRANTED ARE NON-
TRANSFERABLE TO OTHER PARTIES WITHOUT
THE PRIOR EXPRESSED WRITTEN CONSENT OF
CAOLO & BIENIEK ASSOCIATES, INC.
A
1
B
C
D
E
F
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A-700.00
202133FINISHESNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX
MRRJH
CE
ROOM FINISH SCHEDULE
RM # ROOM NAME
FLOOR
MATERIAL
FLOOR
FINISH BASE
NORTH WALL
MAT'L.
NORTH WALL
FINISH
EAST WALL
MAT'L.
EAST WALL
FINISH
SOUTH WALL
MAT'L.
SOUTH WALL
FINISH
WEST WALL
MAT'L.
WEST WALL
FINISH COMMENTS
101 COFFEE SHOP &
SPEAKEASY
CONC. CPT., LVT VSB GWB WC GWB WC GWB WC GWB WC WINDOW TREATMENTS TBD;
H.M. FRAMES, PAINT
102 KITCHEN CONC. LVT - GWB FRP GWB FRP GWB FRP GWB FRP BASE - INTEGRAL FRP; H.M.
FRAME, PAINT.
103 T.R. CONC. EX'G EX'G GWB EX'G GWB EX'G GWB EX'G GWB EX'G
104 T.R. CONC. EX'G EX'G GWB EX'G GWB EX'G GWB EX'G GWB EX'G
1 1/2" = 1'-0"A-700.00
E5 TRANSITION - VCT TO CARPET
1/4" = 1'-0"A-700.00
F1 FLOOR PLAN DATEDESCRIPTION1 1/2" = 1'-0"A-700.00
E7 TRANSITION - LVT TO CARPET FLUSH
CEILING KEY:
SYMBOL
RECESSED 2' X 2' LIGHT FIXTURES, REUSED /
RELOCATED.
DESCRIPTION SYMBOL DESCRIPTION
ILLUMINATED EXIT SIGN, EX'G TO REMAIN
NOTE: REFER TO MEP DRAWINGS AND CEILING SCHEDULES FOR ADDITIONAL INFORMATION
RECESSED DOWNLIGHT FIXTURE, NEW (OR EX'G IF
NOTED IN PLAN)
2' X 2' ACOUSTIC CEILING TILE
GYPSUM CEILING
WALL SCONCE FIXTURE
LIGHT SWITCH W/ OCCUPANCY SENSOR (TYP.)
LIGHT SWITCH (NO OCCUPANCY SENSOR)
NOTE: REFER TO FINISHES PLAN A-100.00 FOR DUPLEX RECEPTACLE &
DATA OUTLET LOCATIONS IN CONTRACT. VERIFY ALL MOUNTING
HEIGHTS / LOCATIONS W/ OWNER.
CEILING MOUNTED ILLUMINATED EXIT SIGN
WITH ARROW AS SHOWN IN PLAN
RECESSED WALL WASH FIXTURE
EX'G GRID PROVIDE NEW,
CLEANABLE SUSPENDED
ACOUSTICAL CEILING TILES
REUSED AND RELOCATE
LIGHTING FIXTURES
TIN CEILING (BLACK)
SUSPENDED ACOUSTICAL CEILNG
TILES, BLACK, TYP.
OUTLINE OF
BAR
BELOW
AREA OF SPECIALTY
GRILLE CEILNG TBD.
D D DE
D D
D DE
D D
D D
D D
D D DE
A A A
A A A
X
BAR LIGHTING TBD
S
S
S
S
S
D
W W
W
W
W W W
D
D
D
D
D
EX'G EX'G
EX'G
EX'G
3' - 0"3' - 0"3' - 0"D
DE
A.F.F.
2' x 2' ACT System
8' -6"
A.F.F.
5/8" GWB SOFFIT
8' -0"
EX'G GWB
SOFFIT
Type Manufacturer Catalog # Mounting Method # of Lamps Lamp Type Lamp Description Voltage Input Watts Line Comments
LIGHTING SPECIFICATIONS
A LITHONIA LIGHTING EPANL 2X2 3400LM 80CRI 30K MIN1 ZT MVOLT RECESSED 1 LED 32 UNV 32 REUSE / RELOCATE: DLC LISTED 3400 LUMEN FLAT PANEL WITH 0-10V DIMMING TO 1%
D ACULUX INIT3 D 15LM 30K 80CRI 50D EZ1 MVOLT / RECESSED 1 LED 16 UNV 16 3IN BLACK BEVEL TRIM DOWNLIGHT WITH 1600 DELIVERED LUMENS WITH 0-10V DIMMING TO 1%
NT3DBV BD BLSF / HB26ACULUX
DE ACULUX INIT3 D 15LM 30K 80CRI 50D EZ1 MVOLT / RECESSED 1 LED 16 UNV 16 3IN BLACK BEVEL TRIM DOWNLIGHT WITH 1600 DELIVERED LUMENS WITH 0-10V DIMMING TO 1%
NT3DBV BD BLSF / HB26ACULUX CONNECTED TO EMERGENCY LIGHTING INVERTER
S SURFACE 1 LED SURFACE MOUNT INTERIOR WALL SCONCE FIXTURE W/ DIMMING TO 1%, TBD
UC KELVIX SX-30K-300-24V/SX-TRX-1F-PAK-P/FML-2C-6/ULV96 LED UNDER BAR COUNTER / WORKSURFACE ILLUMINATION
W ACULUX INITIA INT3 3" APERTURE LENSED WALLWASH FIXTURE RECESSED LED BLACK PAINT OR BLACK SPECULAR FINISH TBD
X ISOLITE CORP. UEL-EM-G-1C2M-MTEBR CEILING 1 LED 3 UNV 3 EDGE LIT UNIVERSAL SINGLE AND DOUBLE FACE EXIT WITH GREEN LETTERS AND INTEGRAL
EMERGENCY BATTERY BACK-UP
SCALE:
PROJECT NO:
c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED
PROJECT MANAGER:
PROJECT ARCHITECT:
PRODUCTION LEADER:
PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE:
THIS DRAWING IS THE PROPERTY OF CAOLO &
BIENIEK ASSOCIATES, INC. THE RE-USE OR
REPRODUCTION OF THIS DRAWING FOR ANY
PURPOSE WHATSOEVER WITHOUT AN
EXPRESSED WRITTEN AGREEMENT BETWEEN
CAOLO & BIENIEK ASSOCIATES INC. AND THE
USER IS STRICTLY PROHIBITED. RIGHTS TO
USE THE INFORMATION ON THIS SHEET ARE
NOT TRANSFERRED UNTIL PAYMENT HAS
BEEN RECEIVED FOR SERVICES RENDERED.
ANY RIGHTS SO GRANTED ARE NON-
TRANSFERABLE TO OTHER PARTIES WITHOUT
THE PRIOR EXPRESSED WRITTEN CONSENT OF
CAOLO & BIENIEK ASSOCIATES, INC.
A
1
B
C
D
E
F
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A-900.00
202133REFLECTEDCEILING PLANNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX
MRRJH
CE
1/4" = 1'-0"A-900.00
F1 REFLECTED CEILING PLAN DATEDESCRIPTIONNOTE: EX'G GRID IN PUBLIC
AREA TO BE
ELECTROSTATICALLY
PAINTED TO MATCH TILES.
NOTE: PROVIDE (5) NEW
EXTERIOR SCONCES, TYPE
SL-1, AT WINDOWS,
LOCATIONS TO BE
CONFIRMED BY OWNER.
1. ROUGH-INS SHOWN ON THE ROUGH-IN DRAWINGS ARE FOR EQUIPMENT BEING
SUPPLIED BY KEC ONLY. ADDITIONAL ROUGH-INS SHOWN OR NOT SHOWN ON
THESE DRAWINGS FOR EQUIPMENT BEING RELOCATED, REUTILIZED OR
SUPPLIED BY OTHERS WILL HAVE TO BE VERIFIED BY CORRESPONDING PRIME
CONTRACTOR (EC, PC, MC, GC) PRIOR TO ROUGH-INS BEING INSTALLED.
SINGER EQUIPMENT COMPANY WILL NOT BE RESPONSIBLE FOR THESE
ROUGH-INS.
2. THE MECHANICAL PLANS ARE PREPARED AS AN ACCOMMODATION AND
GUIDE ONLY, TO INDICATE MECHANICAL REQUIREMENTS NECESSARY TO
OPERATE THE EQUIPMENT. DEVIATIONS FROM THE MECHANICAL WORK
SHOWN ON THESE PLANS AND EXECUTION OF SUCH WORK IS WITHOUT
RESPONSIBILITY OF SINGER EQUIPMENT COMPANY.
3. DATA ON THIS SHEET IS TO BE REVIEWED BY OWNER AND/OR ARCHITECT AND
IS TO BE INCORPORATED INTO THE BUILDING MECHANICAL PLANS IN
ACCORDANCE WITH LOCAL CODES.
4. OWNER AND/OR ARCHITECT IS TO SUBMIT THIS PLAN SET TO LOCAL HEALTH
DEPARTMENT FOR APPROVAL UNLESS OTHERWISE SPECIFIED.
5. ALL EQUIPMENT BEING FURNISHED, PER THIS SET OF PLANS, BY KEC, HAS
THE UNDERWRITERS' LABORATORIES AND NATIONAL SANITATION
FOUNDATION SEALS OF APPROVAL.
6. KEC TO SET EQUIPMENT AT THE SITE IN ACCORDANCE WITH THESE PLANS
AND TERMS OF CONTRACT WITH OWNER.
7. ALL PLUMBING, ELECTRICAL AND VENTILATION WORK, INCLUDING "ROUGH-IN"
AND "FINAL CONNECTIONS" TO THE EQUIPMENT, IS TO BE PERFORMED BY
OTHERS. IT IS NOT PART OF KEC CONTRACT UNLESS OTHERWISE SPECIFIED.
8. TO EXPEDITE AND ENSURE PROPER INSTALLATION OF COOKING EQUIPMENT,
"ALL FINAL CONNECTIONS"ARE TO BE PERFORMED BY OTHERS AT THE SAME
TIME THE KEC IS SETTING THE EQUIPMENT IN PLACE.
9. IF CONTRACTED, KEC SHALL FURNISH AND INSTALL ALL NECESSARY
REFRIGERATION LINES FROM THE COMPRESSORS TO THE EVAPORATOR
COILS IN THE WALK-IN BOXES. REFER TO MANUFACTURER'S FINAL APPROVED
SPECIFICATIONS & DRAWINGS.
10. GC AND/OR MILLWORK PROVIDER TO FURNISH AND INSTALL RUBBER
GROMMETS FOR ALL COUNTER TOP CUT OUTS MADE FOR MECHANICAL
CONNECTIONS AS REQUIRED.
11. CONVENIENCE OUTLETS AND AREA FLOOR DRAINS TO BE LOCATED AND
PROVIDED BY THE RESPECTIVE TRADES AND IN ACCORDANCE WITH LOCAL
CODES.
12. FOOD SERVICE EQUIPMENT SHALL BE INSTALLED SO THAT EQUIPMENT
CONFORMS TO AT LEAST ONE OF THE FOLLOWING:
A. MOVEABLE EQUIPMENT IS PROVIDED WITH CASTERS (AND
RESTRAINING DEVICES AS REQUIRED).
B. FIXED EQUIPMENT IS SEALED TO WALLS, FLOORS, OR ADJACENT
EQUIPMENT.
C. FIXED FLOOR-MOUNTED EQUIPMENT IS INSTALLED WITH 6"
CLEARANCE FROM THE FLOOR.
13. GC SHALL PROVIDE AND COORDINATE WITH KEC (AS REQUIRED) ALL BUILDING
OPENINGS AND CONDITIONS (REFER TO PLANS FOR LOCATIONS, SIZES AND
DETAILS), INCLUDING BUT NOT LIMITED TO:
A. RECESSED FLOORS AND OPENINGS FOR INSTALLATION OF FLOOR
TROUGHS AND WALK-IN COOLER(S) & FREEZER(S) ;
B. OPENINGS FOR INSTALLATION OF CONTROL PANELS;
C. OPENINGS THROUGH FINISHED CEILINGS AND (IF REQUIRED)
THROUGH ROOF TO SERVICE ROOF-MOUNTED FOODSERVICE
EQUIPMENT;
D. STRUCTURAL SUPPORT TO HANG HOODS AND OTHER CEILING-
SUPPORTED EQUIPMENT.
E. PENETRATIONS THROUGH STRUCTURE AND CHASES (PVC OR EMT
SLEEVE) FOR REMOTE REFRIGERATION LINES AND BEVERAGE LINES.
ALL PENETRATIONS THROUGH STRUCTURE TO BE SEALED BY GC AS
REQUIRED BY CODE.
14. IF CONTRACTED, KEC SHALL PROVIDE REMOVABLE ENCLOSURE PANELS
FROM THE TOP OF THE WALK-IN COOLER(S) AND/OR FREEZER(S) AND
EXHAUST HOODS TO FINISHED CEILING. CEILING HEIGHTS TO BE VERIFIED
PRIOR TO FABRICATION. REFER TO MANUFACTURER'S FINAL APPROVED
SPECIFICATIONS & DRAWINGS.
15. GC SHALL PROVIDE WALL BLOCKING IN WALLS, AS DETAILED IN THE
FOODSERVICE SPECIAL CONDITIONS PLAN.
16. GC TO ENSURE ALL EQUIPMENT RUNS ABOVE FINISHED CEILING DO NOT
INTERFERE WITH ANY CEILING HUNG EQUIPMENT SPECIFIED AND SHOWN ON
THESE DRAWINGS.
GENERAL NOTES GENERAL NOTES
1. THE INFORMATION SHOWN ON THE ELECTRICAL PLAN(S) IS FOR FOOD
SERVICE EQUIPMENT ONLY AND THE RESPONSIBILITY OF THE GC/EC UNLESS
OTHERWISE SPECIFIED. FOR ALL OTHER REQUIREMENTS, SUCH AS INTERIOR
AND EXTERIOR LIGHTING, TOILET FACILITIES, EXHAUST FANS, WALL
OUTLETS AND TELEPHONES, SEE ARCHITECTS AND ELECTRICAL
ENGINEERING DRAWINGS.
2. EC TO DO ALL ROUGH-INS AND MAKE ALL FINAL CONNECTIONS TO
EQUIPMENT. EC TO FURNISH ALL TRIM, ACCESSORIES, DISCONNECTS,
CONTACTORS, SWITCHES, RELAYS, ETC, AS REQUIRED.
3. ALL WIRING AND CONDUIT TO BE CONCEALED.
4. EC TO ACCOMMODATE ALL PREVAILING LOCAL ELECTRICAL CODES AS
REQUIRED.
5. EC TO REFER TO ARCHITECTURAL AND ELECTRICAL ENGINEERING PLANS
AND SPECIFICATIONS (BY OTHERS) FOR COMPLETE SCOPE OF WORK.
6. EC TO PROVIDE REQUIRED CONVENIENCE RECEPTACLES AS PER LOCAL
CODE HAVING JURISDICTION AND PER OWNER'S NEEDS.
7. GFI RECEPTACLES ARE NOT RECOMMENDED FOR THE KITCHEN EQUIPMENT
SHOWN ON THESE DRAWINGS. KITCHEN EQUIPMENT SHOULD PLUG INTO A
NON-GFI DEDICATED RECEPTACLE FOR THAT PIECE OF EQUIPMENT. KEC
WILL NOT BE HELD RESPONSIBLE FOR ANY SERVICE OR WARRANTY WORK
RELATED TO KITCHEN EQUIPMENT THAT TRIPS A GFI RECEPTACLE. IT IS
RECOMMENDED THE ELECTRICAL ENGINEER OR ELECTRICAL CONTRACTOR
OBTAIN A VARIANCE IF CODES OR OTHER DRAWINGS FOR THIS PROJECT
REQUIRE GFI RECEPTACLES FOR THE KITCHEN EQUIPMENT. GFCI BREAKERS
ARE PREFERRED.
8. MOUNTING HEIGHTS GIVEN ARE TO CENTERLINE OF DEVICE UNLESS
OTHERWISE NOTED.
9. FLOOR MOUNTED DEVICES ARE TO BE MOUNTED WITH A 5 3/4" MAXIMUM
HEIGHT TO TOP OF BOX.
10. EC SHALL FURNISH ALL LABOR AND MATERIALS (INCLUDING, BUT NOT
LIMITED TO, ALL CONTACTORS, RECEPTACLES, J-BOXES, SWITCHES,
INTERWIRING, DISCONNECT SWITCHES, MOTOR STARTERS AND/OR
TRANSFORMERS OR ANY OTHER ELECTRICAL DEVICE REQUIRED TO MAKE
EQUIPMENT OPERATIONAL) TO MAKE FINAL CONNECTIONS FROM SERVICE
ROUGH-INS TO EQUIPMENT AND INTERCONNECTIONS BETWEEN EQUIPMENT,
WITH ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES.
GENERAL ELECTRICAL NOTES
11. ALL POWER CONNECTION POINTS UNDER EXHAUST HOODS ARE TO SHUTDOWN
UPON FIRE SUPPRESSION SYSTEM ACTIVATION PER NFPA 96. EC TO FURNISH
AND INSTALL SHUNT-TRIP BREAKERS FOR THESE CIRCUITS.
12. EC TO VERIFY, FURNISH AND INSTALL REQUIRED ELECTRICAL ROUGH-INS FOR
ALL EXISTING, REUTILIZED AND NEW EQUIPMENT EQUIPMENT BEING SUPPLIED
BY THE OWNER. KEC IS NOT RESPONSIBLE FOR THESE ROUGH-INS.
13. ALL 120 VOLT DUPLEX RECEPTACLES SHALL BE A MINIMUM OF 20.0 AMP
CIRCUITS, UNLESS OTHERWISE NOTED. MOUNT ALL DUPLEX RECEPTACLES
HORIZONTALLY WITH STAINLESS STEEL FACE PLATES, UNLESS OTHERWISE
NOTED.
14. ALL EXPOSED CONDUIT SHALL BE SEALTIGHT OR EPOXY COATED FOR
CLEANING TO COMPLY WITH LOCAL HEALTH CODES. EXPOSED METAL-CLAD
CONDUIT IS NOT ACCEPTABLE.
15. EC TO INTERWIRE FIRE PROTECTION SYSTEM WITH BUILDING ALARM SYSTEM.
16. EC TO SUPPLY ALL NECESSARY CONTACTORS AND/OR SHUNT TRIP BREAKERS
SO THAT ALL POWER TO ELECTRICAL EQUIPMENT BELOW EXHAUST HOODS
WILL BE SHUT-OFF UPON ACTIVATION OF THE FIRE PROTECTION SYSTEM.
17. REMOTE PULL STATION SHALL BE PROVIDED AND INSTALLED BY FPC. EC
SHALL PROVIDE WALL-MOUNTED OCTAGONAL JUNCTION BOX FOR REMOTE
PULL STATION AND 1/2" EMPTY CONDUIT FROM PULL STATION TO FIRE
SUPPRESSION SYSTEM . FPC TO FIELD VERIFY PULL STATION LOCATION WITH
LOCAL FIRE AUTHORITIES.
18. EC TO INTERWIRE LIGHTS, SWITCHES AND DOOR-FRAME HEATERS FOR WALK-
IN COOLER(S)/FREEZER(S). EC TO INTERWIRE CONDENSING UNIT WITH
EVAPORATOR COILS IN WALK-IN COOLERS/FREEZERS. EC TO PROVIDE AND
INSTALL HEAT TAPE AROUND CONDENSATE DRAIN LINES IN WALK-IN
FREEZERS.
19. EC SHALL PROVIDE EMPTY JUNCTION BOX AND UNDER FLOOR CONDUIT AS
NECESSARY BETWEEN POS TERMINAL LOCATION AND ADMINISTRATOR'S
OFFICE. EC SHALL PROVIDE COMPUTER GRADE SEPARATE DEDICATED
CIRCUIT FOR OWNERS POS TERMINAL.
20. EC SHALL INTERWIRE DISPOSER, DISPOSER CONTROLS AND SOLENOID VALVE
PROVIDED BY KEC, PER MANUFACTURER'S SPECIFICATIONS.
21. IT IS RECOMMENDED THAT EC IS TO PROVIDE AT LEAST 50 FOOT CANDLES OF
LIGHT AT ALL WORK SURFACES, ALL FOOD PREPARATION AND KITCHEN WORK
AREAS, AND AT LEAST 20 FOOT CANDLES OF LIGHT IN ALL OTHER AREAS,
LIGHT FIXTURES IN FOOD PREPARATIONS AREAS MUST BE SHIELDED.
GENERAL ELECTRICAL NOTES
GENERAL SPECIAL CONDITIONS NOTES
1. ARCHITECT AND GC TO ENSURE ALL WALLS ARE PROPERLY REINFORCED TO
SUPPORT WALL MOUNTED EQUIPMENT. GC TO PROVIDE AND INSTALL ALL
WALL BLOCKING, UNLESS OTHERWISE NOTED.
2. WALL BLOCKING TO BE 16 GA. GALVANIZED METAL. ALL WALL BLOCKING
SHALL BE CONCEALED AND SECURELY ATTACHED TO FRAMING WITHIN WALLS
(BEHIND DRY WALL AND/OR FINISHES). WALL BLOCKING LENGTHS
SHOWN ARE MINIMUMS. GC TO EXTEND WALL BLOCKING TO NEXT STUD IN
EACH DIRECTION IN STUD WALL CONSTRUCTION. ANY SITE-SPECIFIC
CONDITIONS THAT REQUIRE DEVIATION FROM THESE INSTRUCTIONS, AND NOT
COVERED IN PLAN NOTES, MUST BE COORDINATED WITH KEC PRIOR TO
COMMENCEMENT OF WORK. GC TO USE METAL STUDS.
3. GC SHALL ENSURE ALL WALLS/CEILINGS ARE PROPERLY REINFORCED TO
SUPPORT ALL WALL AND/OR CEILING SUPPORTED EQUIPMENT. GC TO
PROVIDE INTERMEDIATE SUPPORTS TO BUILDING STRUCTURE ABOVE AS
REQUIRED FOR EXHAUST HOODS.
4. GC SHALL VERIFY INSTALLATION HEIGHT OF FINISHED CEILING WITH FOOD
SERVICE EQUIPMENT BELOW AS SHOWN.
5. GC SHALL PROVIDE HOLES, AND SLEEVES THROUGH ROOF, FLOOR(S),
CEILING(S) AND WALLS FOR SODA LINES, BEER LINES, REFRIGERATION LINES
AND UTILITIES. GC TO SEAL ALL PENETRATIONS IN ACCORDANCE WITH LOCAL
FIRE AND BUILDING CODES.
6. GC SHALL PROVIDE 6" OR 8" DIAMETER CONDUIT AND CORE DRILLING TO RUN
SODA AND BEER LINES (PROVIDED BY VENDOR) FROM SODA AND BEER
SYSTEM (S) TO POINT(S) SHOWN FOR DISPENSING HEADS. ALL BENDS TO BE
EASY SWEEPS (18" (450mm) RADIUS MIN.). CONDUIT TO RUN ON UNDERSIDE OF
SLAB OR ABOVE FINISHED CEILING AS INDICATED AND SUPPORTED AS
REQUIRED. HAVE ONLY ONE(1) 18" MINIMUM RADIUS SWEEP BEND(45° OR 90°)
AT EACH END. CONDUIT TO BE CONSTRUCTED WITH INTERNALLY SMOOTH,
LEAK TIGHT JOINTS. ALSO AN IN-LINE PULL BOX, AT LEAST 12" X 30" SHOULD
BE PROVIDED FOR ANY STRAIGHT RUN IN EXCESS OF 100 FEET WITH AN
ADDITIONAL BOX PROVIDED FOR EVERY 100 FEET OF RUN. A DIRECTIONAL
CHANGE PULL BOX, AT LEAST 30" SQUARE SHOULD BE USED IN SITUATIONS
WHERE MORE THAN TWO (2) 90° TURNS ARE REQUIRED IN A RUN. PROVIDE
CARLON PV-DUIT PLUS SCHEDULE 40 CONDUIT AND FITTINGS, OR APPROVED
EQUAL. PLUMBING PVC OR CAST IRON IS NOT ACCEPTABLE BUT EMT OR RIGID
ELECTRICAL CONDUIT IS ACCEPTABLE IN THOSE JURISDICTIONS WHERE PVC
IS NOT ACCEPTABLE. SEE TYPICAL CONDUIT DETAIL.
7. GC SHALL PROVIDE 2" (50 mm) DIAMETER CONDUIT (PVC, EMT OR OTHER
MATERIAL REQUIRED BY CODE) FOR RUN OF COMPUTER GRADE CONDUIT.
ALL BENDS TO BE EASY SWEEPS (18" (450mm) RADIUS MIN.), AS REQUIRED BY
OWNER.
8. GC SHALL PROVIDE ALL CLEAR OPENINGS IN WALLS TO RECEIVE FOOD
SERVICE EQUIPMENT. ALLOW 1/2" MINIMUM CLEARANCE ON EACH SIDE AND
TOP(S) OF EQUIPMENT. GC TO COORDINATE WITH KEC ON CONSTRUCTION
AND DELIVERY SCHEDULES.
9. REFRIGERATION CONTRACTOR TO SUPPLY AND INSTALL REFRIGERATION
SUPPLY AND RETURN LINES. GENERAL CONTRACTOR TO COORDINATE WITH
THE KEC AND REFRIGERATION CONTRACTORS.
10. WHEN SPECIFIED AND PART OF KEC SCOPE/CONTRACT, CORNER GUARDS TO
BE 18-20 GUAGE S/S, 2" x 2" x 48", AND SECURED IN THE FOLLOWING MANNER:
A. CORNER GUARDS SECURED TO S/S SURFACE ARE SECURED WITH
"POP" RIVETS AND EDGES SEALED WITH SILICONE. CORNER
GUARDS TO BEGIN AT TOP OF SANITARY COVED MOLDING AND
EXTEND TO A MINIMUM OF 48" AFF.
B. CORNER GUARDS SECURED TO FRP SURFACE ARE TO BE SECURED
WITH CONTACT CEMENT AND EDGES SEALED WITH SILICONE.
C. CORNER GUARDS ARE TO BE SUPPLIED AND INSTALLED BY KEC.
D. GENERAL CONTRACTOR TO PROVIDE TRUE, CONSISTENT 90° ANGLES
TO FACILITATE CORNER GUARD INSTALLATION.
11. WHEN SPECIFIED, S/S WALL CLADDING SHALL BE SECURED TO WALL
SURFACE WITH CONTACT CEMENT AND EDGES ARE SILICONED. IF
CONTRACTED, S/S WALL CLADDING AND STRIPS TO BE SUPPLIED AND
INSTALLED BY KEC.
12. WHEN WALK-IN DEPRESSION IS SPECIFIED, GC TO PROVIDE DEPRESSION
FROM ROUGH SLAB TO TOP OF FINISHED FLOOR TO RECEIVE WALK-IN BOX
PANELS. SEE WALK-IN REFRIGERATOR & FREEZER DETAIL.
13. GC TO PROVIDE DEPRESSION FROM ROUGH GRATING. SEE FLOOR TROUGH
AND GRATING DETAIL.
14. MANUFACTURER RECOMMENDS 750 CFM PER HP FOR AIR COOLEd
COMPRESSORS AND 250 CFM PER HP FOR WATER COOLED COMPRESSORS
FOR PROPER VENTLATION.
15. GC TO PROVIDE CORE DRILLING AND THERMAL BARRIER AS REQUIRED FOR
RECESSED COOLER FLOORING.
16. GC TO PROVIDE CORE DRILLED PENETRATIONS IN FLOOR OR WALL
SUFFICIENT TO ACCESS REFRIGERATION TUBING AND POTENTIAL DRAIN
LINES FOR EACH REFRIGERATION ITEM. GC TO PROVIDE FIRE STOP SEALANT
AS REQ'D BY LOCAL CODE. ROOF PENETRATIONS ARE TO BE THROUGH
APPROVED PITCH POCKETS. (COORDINATE W/ ROOFING CONTRACTOR)
SUBMIT REFRIGERATION PIPING SCHEMATIC TO REFRIGERATION RACK MFG.
FOR REVIEW PRIOR TO ANY WORK COMMENCING ON SITE. NOTE :PROVIDE
FOR "P" TRAPS IN OIL RETURN PIPING LAYOUT. ALL LINES TO BE
INSULATED WITH "ARMA-FLEX" OR EQUAL INSULATION.
17. GC TO SUPPLY & INSTALL ALL ROOF CURBS & PLATFORMS IN ACCORDANCE
WITH REFRIGERATION MANUFACTURER'S PRINTED INSTRUCTIONS.
18. GC TO COORDINATE FINAL LOCATION OF CONDENSING UNITS WITH
CONDENSING UNIT EQUIPMENT SUPPLIER, ARCHITECT AND OWNER.
19. GC TO VERIFY WITH ARCHITECT AND STRUCTURAL ENGINEER THAT THE ROOF
WILL SUPPORT THE CONDENSING UNITS IN THE FINAL LOCATIONS.
20. IF THE CONDENSING UNITS ARE LOCATED MORE THAN 25' AWAY FROM THE
WALK-IN BOX, GC TO NOTIFY SUPPLIER OF CONDENSING UNIT EQUIPMENT
SUPPLIER PRIOR TO INSTALLATION OF ROOF CURBS, PITCH POCKETS AND
CONDENSING UNITS.
21. GC TO VERIFY REFRIGERATION LINE RUN QUANTITY & DIRECTION WITH
OWNER/VENDOR. REFRIGERATION RUNS & STUBS IF DRAWN ARE FOR
REFERENCE ONLY. KEC IS NOT RESPONSIBLE FOR ROUTE, QUANTITY OR
LOCATION.
GENERAL SPECIAL CONDITIONS NOTES GENERAL SPECIAL CONDITIONS NOTES
1. SEE FINAL APPROVED DETAILED MANUFACTURER HOOD AND EXHAUST
DRAWINGS FOR COMMERCIAL KITCHEN VENTILATION SIZES. IT IS THE
RESPONSIBILITY OF THE MECHANICAL ENGINEER TO ENSURE DUCT SIZING AND
INSTALLATION REQUIREMENTS SATISFY LOCAL CODES.
2. IF CONTRACTED, KEC SHALL BE RESPONSIBLE FOR HANGING EXHAUST HOOD(S)
AND MAKE-UP AIR PLENUM(S) IN PLACE AND MAKING THEM READY FOR FINAL
CONNECTION. HVAC CONTRACTOR TO PROVIDE AND INSTALL GREASE AND
SUPPLY DUCT FROM HOODS TO EXHAUST FOR HOODS, FANS AND MAKEUP AIR
UNIT. WHEN TYPE 1 (GREASE) EXHAUST IS PRESENT, FPC SHALL SUPPLY ALL
NECESSARY COMPONENTS FOR FULLY OPERATIONAL, UL-LISTED, WET
CHEMICAL FIRE SUPPRESSION SYSTEM, INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS AND COMPLIANT WITH ALL REQUIRED
NFPA AND LOCAL CODES.
3. MEP SHALL VERIFY EXHAUST & SUPPLY DUCT RUNS WITH HVAC CONTRACTOR,
AND BE RESPONSIBLE FOR COORDINATION/REVISION OF CONNECTIONS WITH
PROJECT ENGINEERS AND CONTRACTORS FOR ALL COMMERCIAL KITCHEN
VENTILATION EQUIPMENT. FPC TO FIELD VERIFY FIRE SUPPRESSION SYSTEM
PULL STATION LOCATION WITH LOCAL FIRE AUTHORITIES.
4. HVAC CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE
FINAL CONNECTIONS FROM EACH DUCT CONNECTION, WITH ALL WORK DONE IN
ACCORDANCE WITH ALL LOCAL CODES. SEE MECHANICAL ENGINEERING PLANS
AND SPECIFICATIONS (BY OTHERS) FOR COMPLETE SCOPE OF WORK.
5. IF CONTRACTED, ALL KITCHEN EQUIPMENT EXHAUST AND SUPPLY FANS AND
CONTROLS ARE TO BE PROVIDED BY KEC UNLESS OTHERWISE NOTED.
ROOFTOP EQUIPMENT SHALL BE RIGGED BY GC AND INSTALLED BY HVAC
CONTRACTOR AND EC.
6. HEAT SENSOR FOR DUCTS SHALL BE PROVIDED BY HOOD EQUIPMENT SUPPLIER
UNLESS OTHERWISE NOTED IN SPECIFICATIONS. HEAT SENSOR SHALL MEET
THE REQUIREMENTS TO ACTIVATE EXHAUST FANS WHEN OPERATION OF
COOKING EQUIPMENT OCCURS.
7. IT SHALL BE THE HVAC CONTRACTOR'S RESPONSIBILITY TO PERFORM ALL
REQUIRED AIR BALANCING AND FINAL ADJUSTMENTS TO EXHAUST & MAKE-UP
AIR SYSTEMS FOR FINAL BUILDING DEPT. APPROVAL.
8. MEP ENGINEER TO ENSURE ADEQUATE VENTILATION FOR PROPER HEAT
REJECTION OF REFRIGERATION CONDENSING UNITS.
GENERAL HVAC & KITCHEN VENTILATION NOTESGENERAL PLUMBING NOTES
1. THE INFORMATION SHOWN ON THESE PLUMBING PLANS IS FOR THE FOOD
SERVICE EQUIPMENT ONLY AND THE RESPONSIBILITY OF THE GC/PC UNLESS
OTHERWISE SPECIFIED. FOR OTHER REQUIREMENTS SUCH AS TOILET
FACILITIES, AREA FLOOR DRAINS ETC., SEE ARCHITECTURAL AND PLUMBING
ENGINEERING PLANS.
2. PC TO DO ALL ROUGH-INS AND MAKE ALL FINAL CONNECTIONS TO EQUIPMENT
AND INTERCONNECTIONS BETWEEN EQUIPMENT. PLUMBER TO FURNISH ALL
TRIM, ACCESSORIES, VALVES, PRESSURE REGULATORS, P-TRAPS, GREASE
TRAPS, DRAIN LINES AND BACKFLOW PREVENTION SYSTEM DEVICES, ETC. ALL
PREVAILING LOCAL PLUMBING CODES TO BE ACCOMMODATED.
3. SHUT-OFF VALVES ON THE INLET SIDE OF THE COLD AND HOT WATER LINES
SERVING EACH PIECE OF EQUIPMENT, ARE TO BE FURNISHED AND INSTALLED
BY THE PC.
4. IF WATER PRESSURE AT THE EQUIPMENT AREA EXCEEDS 50 POUNDS FLOW
PRESSURE OWNER OR HIS CONTRACTOR MUST INSTALL A PRESSURE
REDUCING VALVE ON BOTH THE MAIN HOT WATER AND COLD WATER SUPPLY
LINES SERVICING THE AREA.
5. FLOW PRESSURE TO DISHWASHER (OR ITS AUXILIARY HOT WATER BOOSTER
HEATER IF ONE IS USED) MUST NOT EXCEED 25 POUNDS.
6. GC/PC MUST PROVIDE AN ADEQUATE SUPPLY OF 140°F HOT WATER TO ALL
COOKING EQUIPMENT, DISHWASHER/BOOSTER HEATER AND SCULLERY SINKS.
110°F HOT WATER IS TO BE PROVIDED TO ALL OTHER SINKS.
7. IF WATER EXCEEDS TEN GRAINS OF HARDNESS, OR EXCESSIVE LIME, IRON,
ALKALINE, ETC. CONDITIONS ARE PRESENT, PROPER WATER CONDITIONING
EQUIPMENT MUST BE INSTALLED ON THE MAIN WATER LINES SERVING THIS
FOOD SERVICE FACILITY. ALL WATER CONDITIONING EQUIPMENT SHALL BE
FURNISHED, INSTALLED AND MAINTAINED BY OTHERS.
8. USING PVC PIPING FOR DRAIN LINES FROM EQUIPMENT THAT DISCHARGES HOT
WATER SUCH AS STEAMERS & DISHWASHERS MAY CAUSE THE PVC PIPING TO
SOFTEN OR CRACK. IT IS RECOMMENDED THAT METAL (COPPER OR
GALVANIZED) PIPING BE USED.
9. PC TO PROVIDE GREASE INTERCEPTOR(S) AS CODE REQUIRES. PLUMBER TO
SIZE AND FURNISH GREASE INTERCEPTOR(S) PER SPECIFICATIONS. PLUMBER
TO CHECK WITH LOCAL CODES TO DETERMINE WHAT EQUIPMENT IS TO BE
PIPED THROUGH A GREASE TRAP. SEE PLUMBING ENGINEERING DRAWINGS
AND SPECIFICATIONS (BY OTHERS) FOR DETAILS.
10. PC TO EXTEND ALL INDIRECT WASTE LINES FOR FOOD SERVICE EQUIPMENT TO
THE NEAREST FLOOR DRAIN(S) OR FLOOR SINK(S) BY PC AS REQUIRED, UNLESS
OTHERWISE SPECIFIED.
11. PC TO RUN LINES FOR DISHMACHINE(S) AND CONVEYOR(S) TIGHT TO
EQUIPMENT TO INSURE MAXIMUM FLOOR TO EQUIPMENT CLEARANCE.
12. PC TO INSTALL MECHANICAL GAS SHUT OFF VALVE IN GAS MAIN FEEDING ALL
COOKING EQUIPMENT PRIOR TO ANY TEES OR GAS LOOP FEEDING COOKING
EQUIPMENT. MECHANICAL SHUT OFF VALVE TO BE INSTALLED IN ACCESSIBLE
CEILING SPACE OR BELOW FLOOR WITH ACCESS TO VALVE.
13. WHEN SPECIFIED, PLUMBER SHALL PROVIDE AND RUN HOT WATER LINES
FROM WATER WASH CONTROL PANEL(S) TO CONNECTION(S) SHOWN AT
VENTILATOR(S).
14. PC TO PROVIDE FLOOR DRAINS AS PER LOCAL CODE HAVING JURISDICTION
AND OWNER'S REQUEST.
15. PC IS TO REVIEW ALL CATALOG DATA PROVIDED BY THE KEC TO ESTABLISH
THE NECESSARY GAS PRESSURE TO THE KITCHEN EQUIPMENT. IF GAS
PRESSURE TO KITCHEN EQUIPMENT IS HIGHER THAN REQUIRED, A PRESSURE
REGULATOR IS TO BE PROVIDED BY THE PLUMBING CONTRACTOR OR BY THE
GAS COMPANY. THE GAS PRESSURE REGULATOR MUST BE INSTALLED PRIOR
TO THE GAS FEEDING ANY KITCHEN EQUIPMENT. EXCESSIVE GAS PRESSURE
TO THE EQUIPMENT CAN DAMAGE THE EQUIPMENT AND CAUSE PERSONAL
INJURY.
16. INTERCONNECTIONS BETWEEN BOOSTER HEATER AND DISHWASHER, AS WELL
AS GENERATOR AND STEAM EQUIPMENT TO BE PROVIDED BY THE PLUMBING
CONTRACTOR.
17. PC TO VERIFY, FURNISH AND INSTALL REQUIRED PLUMBING ROUGH-INS FOR
ALL EXISTING,RE-UTILIZED AND NEW EQUIPMENT BEING SUPPLIED BY THE
OWNER. KEC IS NOT RESPONSIBLE FOR THESE ROUGH-INS.
18. MANUFACTURERS OF GAS APPLIANCES REQUIRE A 7" WC AT THE POINT OF
CONNECTION.
19. PC TO PROVIDE A WATER CONNECTION TO BYPASS WATER FILTER
CONNECTIONS SO THAT WATER FILTERS MAY BE TEMPORARILY BYPASSED.
20. KEC PROVIDES WATER FILTER INFORMATION FOR REFERENCE ONLY. FINAL
WATER CONNECTION SPECIFICATION TO BE VERIFIED WITH SCOPE OF USE,
APPLICATION, ZIP CODE AND WATER QUALITY TESTING. GC/PC TO VERIFY
FINAL SPECIFICATION AND LOCATION IN FIELD. KEC IS NOT RESPONSIBLE FOR
RE-SIZING OR RELOCATION OF WATER FILTERS DUE TO SCOPE OF USE,
APPLICATION, WATER QUALITY OR FIELD CONDITIONS.
21. PC TO SUPPLY & INSTALL ALL GAS, WATER & DRAINS REQUIRED BY MAKE-UP
AIR SYSTEM. ALL SERVICES TO HAVE SHUT-OFF VALVES AT UNITS.
22. EXPOSED PIPING RUNS SHALL BE AS SHORT AS POSSIBLE.
23. GAS & WATER QUICK DISCONNECTS, WHEN SPECIFIED BY KEC, SHALL BE
PROVIDED BY KEC. INSTALLATION SHALL BE BY THE PLUMBING CONTRACTOR.
24. PC SHALL INSTALL SOLENOID VALVE AND VACUUM BREAKER PRIOR TO
WATER INLET OF DISPOSER (WHEN SPECIFIED).
GENERAL PLUMBING NOTES
A -AMPS
AFC -ABOVE FINISHED CEILING
AFF -ABOVE FINISHED FLOOR
AV -AUDIO-VISUAL
BTC -BRANCH TO CONNECT
BTU -BRITISH THERMAL UNIT
CFM -CUBIC FEET PER MINUTE
CHWR -CHILLED WATER RETURN
CHWS -CHILLED WATER SUPPLY
CP -CORD & PLUG
CO -CONVENIENCE OUTLET
CR -CONVENIENCE RECEPTACLE
c, CW -COLD WATER
DFA -DOWN FROM ABOVE
DN -DOWN
DR -DUPLEX RECEPTACLE
DW -DIRECT WASTE
d, DRN -DRAIN
DS -DISCONNECT SWITCH
EC -ELECTRICAL CONTRACTOR
EMT -ELECTRIC METAL TUBING
EOF -ELECTRICAL OUTLET IN FLOOR
fd, FD -FLOOR DRAIN
ffd, FFD -FUNNEL FLOOR DRAIN
fs, FS -FLOOR SINK
FSEC -FOODSERVICE EQUIPMENT
CONTRACTOR
FP -FIRE PULL BOX
FPC -FIRE PROTECTION CONTRACTOR
fw, FW -FILTERED WATER
G,g -GAS
GC -GENERAL CONTRACTOR
GFI -GROUND FAULT INTERCEPT
GT -GREASE TRAP
GU -GENERAL USE
HP -HORSE POWER
HVAC -HEATING/VENTILATION
/AIR CONDITIONING
ABBREVIATIONS
h, HW -HOT WATER
ID -INSIDE DIAMETER
IPS -IRON PIPE SIZE
IW -INDIRECT WASTE
JB -JUNCTION BOX
KEC -KITCHEN EQUIPMENT
CONTRACTOR
KW -KILOWATTS
LP -LIQUID PROPANE
MEP -MECHANICAL,ELECTRICAL
& PLUMBING ENGINEER
MT -MOUNT
MTD -MOUNTED
NIC -NOT IN CONTRACT
NTS -NOT TO SCALE
NSOD -NOT SHOWN ON DRAWING
OD -OUTSIDE DIAMETER
OOW -OUT OF WALL
PC -PLUMBING CONTRACTOR
PH -PHASE
POS -POINT OF SALE
PSI -POUNDS PER SQUARE INCH
PRP -PRESSURE RELIEF PORT
RECEP -RECEPTACLE
RPM -REVOLUTIONS PER MINUTE
S -STEAM
S/S -STAINLESS STEEL
SD -SMOKE DETECTOR
SDFA -STUB DOWN FROM ABOVE
SOOW -STUB OUT OF WALL
SP -STATIC PRESSURE
SR -SINGLE RECEPTACLE
SW -SWITCH
V -VOLTAGE
VIF -VERIFY IN FIELD
W -WATTS
W/-WITH
WC -WATER COLUMN
xxx
x
ROUGH-IN NUMBER
DETAIL DRAWING REFERENCE
ELECTRIC STUB
120V SINGLE RECEPTACLE
120V DUPLEX RECEPTACLE
120V QUADPLEX RECEPTACLE
208V RECEPTACLE
SWITCH
ELECTRIC SYMBOLS
J
D
JBOX
DATA LINES
DISCONNECT SWITCH
CONDUIT
DC01 120V 1PH DUPLEX CONVENIENCE OUTLET
AFF HT PER PLAN.
DC02 208V 1PH DUPLEX CONVENIENCE OUTLET
AFF HT PER PLAN.
xxx
x
PLUMBING SYMBOLS
ROUGH-IN NUMBER
DETAIL DRAWING REFERENCE
GAS
COLD WATER
HOT WATER
DRAIN
FLOOR DRAIN
FLOOR SINK
EQUIPMENT INDIRECT WASTE
FUNNEL FLOOR DRAIN
CHILLED WATER SUPPLY & RETURN
XXX
X
S
C
R
ROUGH-IN NUMBER
DETAIL DRAWING REFERENCE
SODA CONDUIT, LINES, BUNDLE
CHILLED DRINKING WATER LINE
REFRIGERATION LINES
S/S CORNER GUARD
S/S WALL CLADDING
WALL BACKING
SPECIAL CONDITIONS SYMBOLS
B BEER CONDUIT, LINES, BUNDLE
w WINE CONDUIT, LINES, BUNDLE
3'-6" 3'-6"1 WALL SHELVING
WALL BLOCKING DETAIL. NOT TO SCALE 3'-0" 4'-0"3 PRE-RINSE
BRACKET
WALL BLOCKING DETAIL. NOT TO SCALE 1'-8" 5'-6"4 MOP SINK &
SHELVES
WALL BLOCKING DETAIL. NOT TO SCALE 2'-0" 6'-0"2 HAND SINK
WALL BLOCKING DETAIL. NOT TO SCALE 4'-0" 4'-0"5 WATER FILTER
WALL BLOCKING DETAIL. NOT TO SCALE DIM ADIM B6 AS NOTED ON PLAN
WALL BLOCKING DETAIL. NOT TO SCALE
7 S/S CORNER GUARDS &
ENCLOSURE STRIPS
NOT TO SCALE
WALK-IN
WALL
S/S CORNER
ENCLOSURE GUARD
WALL
WALL
S/S CORNER GUARD
8 S/S WALL PANELS
NOT TO SCALE
SEAL
JOINTS
S/S
END
CAP
VERTICAL
GRAIN
VERIFY SCOPE, AND LOCATIONS
WITH OWNER AND ARCHITECT
ADHERE S/S FLASHING TO WALL
W/ FULL BED OF HEAT RESISTANT
MASTIC. VOIDS AND FLEXING OF
METAL ARE NOT ACCEPTABLE
1-1/2"
9 TROUGH DETAIL
PLUMBING/SPECIAL CONDITIONS UTILITY DETAIL.
NOT TO SCALE
QUARRY TILE AND
SETTING BED BY G.C.
FILL AFTER
SET IN
PLACE
BLOCK OUT AS SHOWN ON PLAN
DRAIN PIPE BY PC NOTE: SEE PLUMBING
DRAWING FOR DRAIN LOCATION. FOR
SINGLE DRAIN TROUGHS DRAIN TO BE
DIRECTLY IN CENTER OF PAN.
CAULK BY
PC
10 BEVERAGE CONDUIT
SPECIAL CONDITIONS UTILITY DETAIL. NOT TO SCALE
CEILING
EASY SWEEP
ELBOWS 24" RADIUS
18" MIN. (DO NOT USE
STD. 90 DEG.
ELBOWS. (TYP.)
BEVERAGE
SYSTEM
4" MIN. ABOVE
FINISHED
FLOOR
6" DIA. PVC OR EMT
CONDUIT. PC &GC TO
VERIFY
REQUIREMENTS WITH
LOCAL CODES AND
SODA SYSTEM
SUPPLIER
BEVERAGE
LINES
CONDUIT REQUIREMENTS:
1. 6" OR 8" PVC OR EMT CONDUIT. PC/GC TO VERIFY SIZE WITH
BEVERAGE SUPPLIER.
2. 4" MIN., 6" MAX. STUB-UP ABOVE FINISHED FLOOR.
3. 24" RADIUS (18" MIN.) RADIUS) EASY SWEEP ELBOWS ONLY.
4. CONDUIT MUST BE WATER TIGHT AND PITCHED BACK TO
BEVERAGE SYSTEM. (1/8" PER FOOT SLOPE).
VERIFY BEVERAGE CONDUIT TO RUN OVERHEAD OR BELOW.
11 QUICK DISCONNECT HOSE DETAIL
PLUMBING UTILITY DETAIL. NOT TO SCALE
RESTRAINT CABLE TO BE INSTALLED TO PREVENT GAS
HOSE FROM BEING PULLED LOOSE FROM WALL. ADJUST
CABLE TO SHORTER LENGTH THAN THAT OF THE GAS HOSE.
INSTALL OTHER END OF RESTRAINT CABLE TO MOBILE
COOKING EQUIPMENT.
GAS SUPPLY
MOBILE COOKING EQUIPMENT
HOSE REEL
12 HOSE REEL DETAIL
PLUMBING UTILITY DETAIL. NOT TO SCALE
1/2" NPT
FLEX HOSE
1/2" NPT VACUUM
BREAKER
1/2" NPT PIPING BY
PC
1/2" NPT SHUT OFF
VALVE
MIXING VALVE
1/2" NPT PIPING BY
PC
CHECK VALVES
3/8" BLEEDER
LINE BY PC
OPTIONAL
BLEEDER
VALVE BY
PC 7'-0" 4'-0" 6 "
8"
13 FLOOR MTD RECEPTACLE
ELECTRIC UTILITY DETAIL. NOT TO SCALE
ELECTRICAL
CONDUIT STUB UP
CONCRETE SLAB
AND/OR FLOOR 5-3/4" TOP OF BOX MAX.14 SNEEZE GUARD HEAT AND/OR
LIGHT WIRING DETAIL
ELECTRIC UTILITY DETAIL. NOT TO SCALE
HEAT AND/OR
LIGHT
FOOD SHEILD
SUPPORT
COUNTER/
MILLWORK
(BY OTHERS)
J.BOX (TYP.)
(BY
OTHERS)
HEAT
CONTROLLER
MOUNTED IN
BOX (BOX BY
OTHERS)
FOR GENERAL REFERENCE. SEE FINAL MANUFACTURERS
SPECIFICATION/INSTALLATION DETAILS
BALLAST BOX
SUPPLY POWER
(TYP.) (BY
OTHERS)
LIGHT SWITCH MTD IN A BOX (BOX
BY OTHERS)
NOTE: E.C. TO IDENTIFY PROPER LEG OF FOOD
SHEILD FOR THE LIGHT AND/OR HEAT WIRING
PRIOR TO WIRING TO SWITCH AND/OR
CONTROLLER.
15 WALK-IN DETAIL: WALK-IN PLACED ATOP SLAB/SUB FLOOR W/ TILE FLOOR IN WALK-IN COOLER AND/OR TILE
TERMINATING INTO WALK-IN PANEL
SPECIAL CONDITIONS DETAIL. NOT TO SCALE
THESE ARE TYPICAL WALK-IN CROSS SECTIONS FOR WALK-INS INSTALLED WITHOUT A DEPRESSED SLAB. PLEASE NOTE THAT THESE CROSS SECTIONS ARE FOR
REFERENCE ONLY AND MAY NOT BE APPLICABLE FOR THIS PARTICULAR PROJECT. PLEASE SEE FINAL APPROVED MANUFACTURERS DRAWINGS.
SECTION THRU WALK-IN
COOLER DOOR
SECTION THRU WALK-IN
COOLER PARTITION OR
EXTERIOR WALK-IN
PANEL
SECTION THRU WALK-IN
COOLER/FREEZER DOOR
W/ RAMP AND INSULATED
FLOOR
SECTION THRU WALK-IN
COOLER/FREEZER DOOR W/
STEP UP AND INSULATED
FLOOR
SECTION THRU WALK-IN
COOLER/FREEZER PANEL
W/ INSULATED FLOOR
AGAINST BUILDING WALL
WALK-IN COOLER DOOR
INTERIOR OR EXTERIOR WALL
PANEL
PERIMETER VINYL
SCREED SECURED TO
CONCRETE FLOOR
FLOOR SCRUBBER
TILE AND SETTING BED
BY GC
HEATER CHANNEL
/THRESHOLD
CONCRETE SLAB OR SUB
FLOOR BY GC
WATERPROOF
MEMBRANE BY
IF REQUIRED BY
GC
WALK-IN WALL PANEL
(4" TYP.)
WALK-IN WALL
FLOOR
SECTION (4"
TYP.)
COVED
TILE TOE
BASE BY
GC
TILE AND
SETTING
BED BY
GC
BUILDING WALL
HEATER
CHANNEL
/THRESHOL
D
WALK-IN
FLOOR
SECTION (4"
TYP.)
WALK-IN COOLER/FREEZER DOOR
1" CLEAR
INTERIOR RAMP
COVED TILE TOE BASE
INSIDE & OUT BY GC
WALK-IN COOLER/FREEZER DOOR
WALK-IN WALL
PANEL (4" TYP.)
PLEASE NOTE THAT THE DETAILS SHOWN ON THIS PAGE ARE FOR GENERAL REFERENCE ONLY AND MAY NOT BE APPLICABLE FOR THIS PARTICULAR PROJECT.
FSEC SHEET LIST
Sheet Number Sheet Name
FS0.00 Notes, Symbols & Details
FS1.10 Equipment & Schedule
FS1.20 Plumbing Rough-in Plan
FS1.30 Electric Rough-in Plan
FS1.40 Special Conditions Plan
FS1.50 Equipment Elevations
FS1.51 Equipment Elevation
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
1/4" = 1'-0"
FS0.00
Notes,
Symbols
& Details
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06- 11 -21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
18" X 36"
18" X 20"18" X 20"18" X 20"24"24"36"W X 24"D18" X 36"
18" X 48"
18" X 36"36"W X 24"D36"W X 24"D18" X 48"72"W X 30"D18" X 36"
18" X 36"18" X 36"24" X 36"24" X 36"
FS1.51 4
FS1.50
2
4
2
SECURE
SHELVING
DISH
REFRIG1-DOOR
REFRIG
FREEEZER
DRY
STORAGE
PREP
SINK W/
POT RACK
H.S.
MOP / MOP BUCKET /
CHEMICAL STORAGE
UC DISH
MACHINE
TRASH
POS
71 72
3
ADA TRANSACTION
COUNTER/ ADA
SEATING COUNTER
3
TRASH
TURBO
CHEF
PANINI
WALL
CONVECTION
W/ SHELF
RACK 185"102"PREP
COCKTAIL
STATION
GLASSES
MUG
FROSTER
COCKTAIL
STATION
GLASSES
REFRIG
WINE
ICE
KOLD-
DRAFT
REFRIG
GLASS-
WASH
WINE
REFRIG234"99"
114"264"1231512
14
11 13
6 6 6
8
8
7
18 23 23 25
1922 21
20
24
30
29
28
36
35
33
41
42
43
44
42
41
43
45
51
52
53
54
55
52
51
67
66
65
64
63
62
61
34
50
FILTER
BAKERY
CASE
56
68
H.S.
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
1/4" = 1'-0"
FS1.10
Equipment
&
Schedule
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06 -11-21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
SINGER EQUIPMENT IS NOT RESPONSIBLE FOR UTILITY AND ROUGH-IN INFORMATION FOR
EQUIPMENT THAT IS SUPPLIED BY OTHERS. ARCHITECT, EC, PC, GC TO VERIFY OWNER
SUPPLIED EQUIPMENT AND EQUIPMENT SUPPLIED BY OTHERS.
EQUIPMENT SCHEDULE
ITEM #QTY DESCRIPTION Manufacturer Model EQUIPMENT REMARK
1 1 Reach-In Refrigerator Per Specification Per Specification
2 1 Reach-In Refrigerator Per Specification Per Specification
3 1 Reach-In Freezer Per Specification Per Specification
4-5 1 Spare Number
6 3 Mobile Work Table Fabricator Fabrication
7 1 Secure Shelving Unit Per Specification Per Specification
8 2 Storage Shelving Unit Per Specification Per Specification
9-10 1 Spare Number
11 1 Mop Sink Fabricator Fabrication
12 1 Service Sink Faucet T&S Brass B-0655-BSTP
WALL BACKING BY G.C.
13 1 Mop Bucket By Owner By Owner
14 1 Mop Holder Fabricator Fabrication
WALL BACKING BY G.C.
15 2 Wire Wall Shelving Per Specification Per Specification
WALL BACKING BY G.C.
16-17 1 Spare Number
18 1 Mobile Rack Per Specification Per Specification
19 1 Three-Bowl Sink Fabricator Fabrication
20 1 Faucet Per Specification Per Specification
21 1 Undercounter Dishwasher NIC By Others UL-100
NIC BY OTHERS; LOW-TEMP; VERIFY w/ OWNER
22 1 Undercounter Trash Can By Owner By Owner
23 4 Wire Wall Shelving Per Specification Per Specification
WALL BACKING BY G.C.
24 1 Hand Sink Fabricator Fabrication
WALL BACKING BY G.C.
25 1 Towel and Soap Dispenser NIC By Others NIC By Others
WALL BACKING BY G.C.
26-27 1 Spare Number
28 1 Prep Sink Fabricator Fabrication
29 1 Faucet Per Specification Per Specification
30 1 Wall Shelf w/ Pot Rack Advance Tabco PS-12-36
WALL BACKING BY G.C.
31-32 1 Spare Number
33 1 Mobile Work Table Fabricator Fabrication
34 1 Convection Oven Winco ECO-500
VENTLESS; WALL-MOUNTED
35 1 Panini Warmer Waring WDG250
36 1 Rapid-Cook Oven TurboChef ECO-950
VENTLESS
37-40 1 Spare Number
41 2 Undercounter Trash Can By Owner By Owner
42 2 Cocktail Station Krowne Metal KR24-MX60-10
43 2 Glass Rack Storage Cabinet Krowne Metal KR24-S18
44 1 Mug Froster Krowne Metal KR24-MF18
45 1 Undercounter Refrigerator Continental BB24NGD
46-49 1 Spare Number
50 1 Combination Water Filter System PENTAIR EV9329-44
MOUNT HIGH NEAR CEILING; WALL BACKING BY
G.C.; SERVICES BACKBAR EQUIPMENT
51 2 Undercounter Refrigerator Continental BB24NGD
52 2 Undercounter Wine Reserve Summit SCR60BLX
53 1 Undercounter Ice Machine Scotsman UC2024MA-1
54 1 Undercounter Ice Machine Kold-Draft SC201
55 1 Undercounter Glasswasher Jackson WWS DELTA 1200
56 1 Undercounter Hand Sink Krowne Metal KR24-12ST
w/ SOAP & TOWEL DISPENSER
57-60 1 Spare Number
61 1 Drink Blender VitaMix QUIET ONE
62 1 Bean Grinder Mahlkonig EK43
63 1 Drop-In Dump Sink Per Specification Per Specification
w/ FAUCET & SIDE SPLASHES
64 1 Bean Grinder Nuova Simonelli MYTHOS II GRAV
65 1 Pitcher Rinser Rhino RHPR600
66 1 Espresso Machine Slayer EP 2-GROUP
67 1 Cold Brew Coffee Dispenser Cornelius NitroPro
68 1 Countertop Ambient Display Case Per Specification Per Specification
69-70 1 Spare Number
71 1 POS nic by others nic by others
72 1 POS PRINTER nic by others nic by others
xxx
x
PLUMBING SYMBOLS
ROUGH-IN NUMBER
DETAIL DRAWING REFERENCE
GAS
COLD WATER
HOT WATER
DRAIN
FLOOR DRAIN
FLOOR SINK
EQUIPMENT INDIRECT WASTE
FUNNEL FLOOR DRAIN
CHILLED WATER SUPPLY & RETURN19"9"87"9"52"96"16"
42
42
42
42
42
44
43
43
4211"13"
12
11
15"15"28
29
13"
32"30"18"20
19
21 24
21
20"
22"
50
50
36"108"65
66
63
53
54
55
24"27"24"30"56
66
65
63
55
54
53
15"24"8"28"67
14"
22"
PC TO EXTEND FILTERED
CW OUT TO BAR AREA
101"
114"
PLUMBING ROUGH-IN SCHEDULE
ITEM #QTY DESCRIPTION CW SIZE
CW RI
HT (AFF)HW SIZE
HW RI
HT (AFF)
DW CONN
SIZE
DW RI HT
(AFF)IW CONN SIZE PLUMBING REMARKS
11 1 Mop Sink 2" 2" PC To Cut Down Drain Pipe As Required
12 1 Service Sink Faucet 1/2" 18" 1/2" 18"PC TO BTC
19 1 Three-Bowl Sink 1 1/2" PC TO BTC. PC TO EXTEND IW TO FLOOR RECEPTACLE AND/OR GREAS TRAP. PC TO VERIFY WITH LOCAL CODE.
20 1 Faucet 1/2" 18" 1/2" 18"PC TO BTC
21 1 Undercounter Dishwasher 1/2" 12"5/8" PC TO BTC; PC TO EXTEND FLEX. IW TO FLOOR RECEPTACLE. FASTEN AND LEAVE AIR GAP.
24 1 Hand Sink 1/2" 16" 1/2" 16" 1 1/2" 21" PC TO BTC
28 1 Prep Sink 2" PC TO BTC; PC TO EXTEND IW TO FLOOR RECEPTACLE
29 1 Faucet 1/2" 16" 1/2" 16"PC TO BTC
42 2 Cocktail Station 1/2" 12" 1/2" 12"1" (2) CW REQUIRED; (5) IW REQUIRED; PC TO EXTEND IW TO FLOOR RECEPTACLE
43 2 Glass Rack Storage Cabinet 1" PC TO EXTEND IW TO FLOOR RECEPTACLE
44 1 Mug Froster 1" PC TO EXTEND IW TO FLOOR RECEPTACLE
50 1 Combination Water Filter System 3/4" 90"PC TO EXTEND FILTERED CW FROM FILTER TO ITEM #'s 53, 54, 66 & 67
53 1 Undercounter Ice Machine 1/2" 12"3/4" FILTERED CW; PC TO EXTEND IW TO FLOOR RECEPTACLE
54 1 Undercounter Ice Machine 1/2" 12"3/4" FILTERED CW; PC TO EXTEND IW TO FLOOR RECEPTACLE
55 1 Undercounter Glasswasher 1/2" 12" 1/2" 12"1 1/2" PC TO EXTEND IW TO FLOOR RECEPTACLE
56 1 Undercounter Hand Sink 1/2" 10" 1/2" 10" 1 1/2" 14"
63 1 Drop-In Dump Sink 1/2" 16" 1/2" 16"1 1/2" PC TO EXTEND IW TO FLOOR RECEPTACLE
65 1 Pitcher Rinser 1/2" 18"3/4" PC TO EXTEND IW TO FLOOR RECEPTACLE
66 1 Espresso Machine 1/2" 48"1" FILTERED CW; PC TO EXTEND IW TO FLOOR RECEPTACLE
67 1 Cold Brew Coffee Dispenser 1/2" 48"FILTERED CW
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
1/4" = 1'-0"
FS1.20
Plumbing
Rough-in
Plan
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06 -11-21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
24"48" 48"J J38"HORIZ38"HORIZ24"
D
24"
D J J48" 48"
xxx
x
ROUGH-IN NUMBER
DETAIL DRAWING REFERENCE
ELECTRIC STUB
120V SINGLE RECEPTACLE
120V DUPLEX RECEPTACLE
120V QUADPLEX RECEPTACLE
208V RECEPTACLE
SWITCH
ELECTRIC SYMBOLS
J
D
JBOX
DATA LINES
DISCONNECT SWITCH
CONDUIT
DC01 120V 1PH DUPLEX CONVENIENCE OUTLET
AFF HT PER PLAN.
DC02 208V 1PH DUPLEX CONVENIENCE OUTLET
AFF HT PER PLAN.
DCO1
82"40"40"
3 2 1
96"21 42"18"8"8"14"36
35
34
DCO1
DCO1
84"50"90"DCO1 DCO1
RETRACTABLE DROP CORD
(VERIFY w/ OWNER)
45
48"32"40"22"30"24"18"51
52
53
54
55
52
5182"108"22"DCO1
DCO1
12"12"
72
7132"67 22"32"26"12"30"54"66
64
62
61
DCO1
DCO1
142"
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
1/4" = 1'-0"
FS1.30
Electric
Rough-in
Plan
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06 -11-21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
ELECTRIC ROUGH-IN SCHEDULE
ITEM #QTY DESCRIPTION VOLTS PHASE AMPS CONN TYPE
ELEC RI
HT (AFF)ELECTRICAL REMARKS
1 1 Reach-In Refrigerator 120 V 1 2.3 A Cord & plug 48"
2 1 Reach-In Refrigerator 120 V 1 5.5 A Cord & plug 48"
3 1 Reach-In Freezer 120 V 1 10.5 A Cord & plug 48"
21 1 Undercounter Dishwasher 120 V 1 12.0 A Cord & plug 24" NIC BY OTHERS. EC TO VERIFY OWNERS SPEC.
34 1 Convection Oven 120 V 1 13.3 A Cord & plug 66"
35 1 Panini Warmer 120 V 1 15.0 A Cord & plug 48"
36 1 Rapid-Cook Oven 208 V 1 20.0 A Cord & plug 48" NEMA L6-20
45 1 Undercounter Refrigerator 120 V 1 2.5 A Cord & plug 24"
51 2 Undercounter Refrigerator 120 V 1 2.5 A Cord & plug 24"
52 2 Undercounter Wine Reserve 120 V 1 0.8 A Cord & plug 24"
53 1 Undercounter Ice Machine 120 V 1 7.8 A Cord & Plug 24"
54 1 Undercounter Ice Machine 120 V 1 6.0 A Direct 24"
55 1 Undercounter Glasswasher 208 V 1 15.0 A Direct 24"
61 1 Drink Blender 120 V 1 15.0 A Cord & plug 48"
62 1 Bean Grinder 120 V 1 11.0 A Cord & Plug 48"
64 1 Bean Grinder 120 V 1 10.0 A Cord & Plug 48"
66 1 Espresso Machine 220 V 1 24.1 A Direct 48"
67 1 Cold Brew Coffee Dispenser 120 V 1 5.0 A Direct 48"
71 1 POS 120 V 1 15.0 A Cord & Plug 24" PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT W/
ISOLATED GROUND & (2) DATA LINE (CAT 5). ROUGH-IN HEIGHT
PER PLAN
72 1 POS PRINTER 120 V 1 5.0 A Cord & plug 24" PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT W/
ISOLATED GROUND & (2) DATA LINE (CAT 5). ROUGH-IN HEIGHT
PER PLAN.
XXX
X
S
C
R
ROUGH-IN NUMBER
DETAIL DRAWING REFERENCE
SODA CONDUIT, LINES, BUNDLE
CHILLED DRINKING WATER LINE
REFRIGERATION LINES
S/S CORNER GUARD
S/S WALL CLADDING
WALL BACKING
SPECIAL CONDITIONS SYMBOLS
B BEER CONDUIT, LINES, BUNDLE
w WINE CONDUIT, LINES, BUNDLE
WALL BACKING 24" AFF TO
CEILING (VERIFY w/ OWNER)
186"72"54"
WALL BACKING 24" AFF TO
84" AFF (VERIFY w/ OWNER)
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
1/4" = 1'-0"
FS1.40
Special
Conditions
Plan
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06 -11-21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
SEE NOTES PAGE FOR WALL BACKING DETAILS AND GENERAL NOTES
18" X 36"
18" X 20"18" X 20"18" X 20"24"24"36"W X 24"D18" X 36"
18" X 48"
18" X 36"36"W X 24"D36"W X 24"D18" X 48"72"W X 30"D18" X 36"
18" X 36"18" X 36"24" X 36"24" X 36"
FS1.51 4
FS1.50
2
4
2
SECURE
SHELVING
DISH
REFRIG1-DOOR
REFRIG
FREEEZER
DRY
STORAGE
PREP
SINK W/
POT RACK
H.S.
MOP / MOP BUCKET /
CHEMICAL STORAGE
UC DISH
MACHINE
TRASH
POS
71 72
3
ADA TRANSACTION
COUNTER/ ADA
SEATING COUNTER
3
TRASH
TURBO
CHEF
PANINI
WALL
CONVECTION
W/ SHELF
RACK 185"102"PREP
COCKTAIL
STATION
GLASSES
MUG
FROSTER
COCKTAIL
STATION
GLASSES
REFRIG
WINE
ICE
KOLD-
DRAFT
REFRIG
GLASS-
WASH
WINE
REFRIG234"99"
114"264"1231512
14
11 13
6 6 6
8
8
7
18 23 23 25
1922 21
20
24
30
29
28
36
35
33
41
42
43
44
42
41
43
45
51
52
53
54
55
52
51
67
66
65
64
63
62
61
34
50
FILTER
BAKERY
CASE
56
68
H.S.VERIFY50
34
2323 2323
18
1921 22
20
36"31"36"12"103 1/2"
24
25
34"10 1/4"66"18
49"
49"VERIFY34
50
30
3536
33 28
29
66"36"
72"23 1/4"
1231311
12
15
1515
48"36"48"66"12"54 1/2"27"54 1/2"
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
As indicated
FS1.50
Equipment
Elevations
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06 -11-21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
1/2" = 1'-0"2 Elevation - BOH Dish and Prep
1/2" = 1'-0"4 Elevation - BOH Warming
1/2" = 1'-0"3 Elevation - BOH Mop / Refrigeration
5 Perspective - BOH6Perspective - BOH 2
18" X 36"
18" X 20"18" X 20"18" X 20"24"24"36"W X 24"D18" X 36"
18" X 48"
18" X 36"36"W X 24"D36"W X 24"D18" X 48"72"W X 30"D18" X 36"
18" X 36"18" X 36"24" X 36"24" X 36"
FS1.51 4
FS1.50
2
4
2
SECURE
SHELVING
DISH
REFRIG1-DOOR
REFRIG
FREEEZER
DRY
STORAGE
PREP
SINK W/
POT RACK
H.S.
MOP / MOP BUCKET /
CHEMICAL STORAGE
UC DISH
MACHINE
TRASH
POS
71 72
3
ADA TRANSACTION
COUNTER/ ADA
SEATING COUNTER
3
TRASH
TURBO
CHEF
PANINI
WALL
CONVECTION
W/ SHELF
RACK 185"102"PREP
COCKTAIL
STATION
GLASSES
MUG
FROSTER
COCKTAIL
STATION
GLASSES
REFRIG
WINE
ICE
KOLD-
DRAFT
REFRIG
GLASS-
WASH
WINE
REFRIG234"99"
114"264"1231512
14
11 13
6 6 6
8
8
7
18 23 23 25
1922 21
20
24
30
29
28
36
35
33
41
42
43
44
42
41
43
45
51
52
53
54
55
52
51
67
66
65
64
63
62
61
34
50
FILTER
BAKERY
CASE
56
68
H.S.
226"
HORIZANTAL ELECTRICAL OUTLETS TO
BE POSITIONED DIRECTLY UNDER
COUNTER TOP SURFACE. ELECTRIC
OUTLETS TO BE POSITIONED CLEAR
ABOVE EQUIPMENT BACKSPLASH
COUNTERTOP AND EQUIPMENT
BACKSPLASH (TYP.)
45 43 41 42 44 43 42 41
24"18"60"18"18"60"
72 71
34"42"24"
68
30"
68
67
66
64
6563
6261
51 52 53 54 55 52 51 56
24"24"24"26"25 1/4"24"24"12"
DRAWING SHEET NO.
SCALE:
JOB NAME:
SHEET NAME:
COPYRIGHT. THESE DOCUMENTS IN PART
OR IN WHOLE, AND THE DESIGN THEY
REPRESENT, ARE THE SOLE PROPERTY OF
SINGER EQUIPMENT COMPANY. THESE
DOCUMENTS ARE INTENDED FOR THE
PROJECT ON SITE INDICATED. ANY USE,
REPRODUCTION, MODIFICATION OR
ADOPTION WITHOUT THE EXPRESS
WRITTEN CONSENT OF SINGER EQUIPMENT
COMPANY IS STRICTLY PROHIBITED.
Singer
Equipment
Company
ADDRESS:
SUBMITTALS & REVISIONS
DATE DESCRIPTIONNAME
DRAWN BY:
CHECKED BY:
PROJECT #:
REV
As indicated
FS1.51
Equipment
Elevation
180 Heller Place,
Bellmawr, NJ
08030
856-559-4200
JCB
JR
06 -11-21 JCB SCHEMATIC
DESIGN
DEVELOPMENT
06-30-21 JCB
ROUGH-INS AND
ELEVATIONS
07-28-21 JCB
REDESIGN PLAN09-22-21 KM
1/2" = 1'-0"2 Elevation - Front Bar
1/2" = 1'-0"3 Elevation - Front Counter
1/2" = 1'-0"4 Elevation - Back Bar
MILLWORK DRAWN FOR REFERENCE ONLY. REFER TO
ARCHITECTRUAL AND OR MILLWORK SHOP DRAWINGS FOR
DETAILS AND DIMENSIONS.
5 Perspective - Front Bar 6 Perspective - Bar