Loading...
202133 - Noho Social Coffee Shop & Speakeasy_Full Set 9.24.21c 2018 CAOLO & BIENIEK ASSOCIATES, INC. ISSUE DATE: 521 East Street Chicopee, Massachusetts CAOLO & BIENIEK ASSOCIATES, INC. ARCHITECTURE · PLANNING · INTERIOR DESIGN 1.413.594.2800 www.cbaarchitects.net PROJECT NO: CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS:CONSULTANTS: Noho Social Coffee Shop & Speakeasy PROGRESS SET SEPTEMBER 24, 2021 202133 261 KING ST, NORTHAMPTON, MA Sheet List Sheet Number Sheet Name GENERAL A-000.00 COVER SHEET ARCHITECTURAL D-100.00 DEMOLITION A-100.00 FLOOR PLAN A-700.00 FINISHES A-900.00 REFLECTED CEILING PLAN MEP FS1.10 EQUIPMENT & SCHEDULE FS1.20 PLUMBING ROUGH IN PLAN FS1.30 ELECTRIC ROUGH-IN PLAN FS1.40 SPECIAL CONDITIONS PLAN FS1.50 FLOOR PLAN - LIGHTING CONTROLS FS1.51 EQUIPMENT ELEVATION LOCATION KEY PLAN 261 KING STREET NORTHAMPTON, MA SINGER EQUIPMENT COMPANY FOOD SERVICE 180 HELLER PLACE BELLMAWR, NJ 08030 856-559-4200 WH EXISTING CONSTRUCTION - TO BE DEMOLISHED EXISTING DOOR & FRAME - TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN. DEMOLITION LEGEND 1. CONTRACTOR SHALL SUBMIT TO THE ARCHITECT/ENGINEER ANY AND ALL DISCREPANCIES TO THE PROPOSED DEMOLITION PRIOR TO EXECUTION OF THE ITEMS IN QUESTION. 2.THE CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL AREAS NOT INCLUDED IN THIS WORK. 3.ALL DEMOLISHED MATERIAL SHALL BE LEGALLY DISPOSED OF BY G.C. 5.GENERAL CONTRACTOR SHALL FIELD MEASURE TO COMPLETE DEMOLITION ACCURATELY. 6.CONTRACTOR SHALL MAINTAIN A REQUIRED FIRE EXTINGUISHER AS REQUIRED BY CODE IN VACANT SPACE 7.SEE PROPOSED STRUCTURAL/ELECTRICAL/MECHANICAL/PLUBMING DRAWINGS FOR REPLACEMENT OF ANY EXISTING ITEMS NOT LISTED IN THE GENERAL DEMOLITION NOTES 8.ROOF TO REMAIN. ALL EXISTING ROOF PENETRATIONS TO BE REMOVED - PATCH ROOF AS NEEDED. 9.NO HAZARDOUS MATERIAL ARE KNOWN TO BE PRESENT IN BUILDING. CONTRACTORS SHOULD NOTIFY OWNER IF ANY SUSPECT MATERIALS ARE ENCOUNTERED PRIOR TO REMOVAL. DEMOLITION GENERAL NOTES 1 1 1 2 3 4 5 6 3 2 TIE INTO EX'G. SANITARY LINE (REPAIR FLOOR FINISHES) AREA OF WORK SCALE: PROJECT NO: c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED PROJECT MANAGER: PROJECT ARCHITECT: PRODUCTION LEADER: PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE: THIS DRAWING IS THE PROPERTY OF CAOLO & BIENIEK ASSOCIATES, INC. THE RE-USE OR REPRODUCTION OF THIS DRAWING FOR ANY PURPOSE WHATSOEVER WITHOUT AN EXPRESSED WRITTEN AGREEMENT BETWEEN CAOLO & BIENIEK ASSOCIATES INC. AND THE USER IS STRICTLY PROHIBITED. RIGHTS TO USE THE INFORMATION ON THIS SHEET ARE NOT TRANSFERRED UNTIL PAYMENT HAS BEEN RECEIVED FOR SERVICES RENDERED. ANY RIGHTS SO GRANTED ARE NON- TRANSFERABLE TO OTHER PARTIES WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT OF CAOLO & BIENIEK ASSOCIATES, INC. A 1 B C D E F 2 3 4 5 6 7 8 A B C D E F 1 2 3 4 5 6 7 8 D-100.00 202133DEMOLITIONNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX MRRJH CE DEMOLITION KEYED NOTES NUMBER DESCRIPTION 1 SAW-CUT CONCRETE SLAB AND EXCAVATE AS REQUIRED TO INSTALL NEW PLUMBING, SEE PLUMBING DWGS. 2 REMOVE ALL CARPET TILE, STACK FOR RELOCATION (BY OTHERS) TO STORAGE FOR FUTURE USE. 3 REMOVE ALL CEILING TILES AND STACK/CRATE FOR RELOCATION (BY OTHERS) 4 REMOVE HVAC GRILLS, SALVAGE FOR REINSTALLATION AND PAINT TO MATCH NEW CEILING COLOR (TBD) 5 REMOVE SPINKLER COVERS AND REPLACE WITH NEW COVERS TO MATCH NEW CEILING TILE ( COLOR TBD) 6 ELECTRICAN TO REMOVE ALL 2X2 LIGHTING IN PUBLIC AREA ( LEAVE IN KITCHEN AREA), STACK W/ PROTECTION FOR RELOCATION (BY OTHERS) 1/4" = 1'-0"D-100.00 G4 TENANT DEMOLITION FLOOR PLAN DATEDESCRIPTION WH 5' - 10"9' - 8"6' - 5"B7 A-100.00 B7 A-100.00 B7 A-100.00 LINE OF EXIST'G SOFFIT ABOVE 102 1547 SF 101 COFFEE SHOP & SPEAKEASY 274 SF 102 KITCHEN 53 SF 103 T.R. 53 SF 104 T.R. 101B 100 103 104 ENCLOSE COLUMN W/ GYP. BOARD NEW. ALUM. & GLASS WALL, SIM. TO ENTRY B5 A-100.00 NOTE: KITCHEN EQUIPMENT SHOWN FOR REFERENCE. SEE KITCHEN PLANS FOR MORE INFORMATION. FD FD J-MOLD, TYP. EXIST'G GRID NEW, CLEANABLE ACOUSTICAL CEILING TILES FRP 5/8" GWB WOOD BLOCKING EXIST'G GRID NEW SUSP. ACOUSTICAL TILE CLG. 6" STEEL STUDS @ 16" O.C., FILL CAVITY WITH INSULATION KITCHEN N FLUSH W/ TEMPERED GLAZING GENERAL NOTE: 1. PROVIDE APPROPRIATE RATED GLAZING ON ALL DOORS WHERE INDICATED ON THE DOOR AND FRAME SCHEDULE. VARIES VARIES SEE DR. SCHEDULE8"6" FR-1 DOOR HEIGHT2"2"2" SEE DR. SCH. FOR SIZES DOOR AND FRAME SCHEDULE TERMS & ABBREVIATIONS: SOLID CORE WOOD ALUMINUM HOLLOW METAL GALVANIZED HOLLOW METAL INSULATED GALVANIZED HOLLOW METAL PREFINISHED OVERHEAD DOOR OVERHEAD DOOR W/ GLAZING COILING DOOR HOUR HARDWARE DUAL EGRESS ELECTRIC DOOR STRIKE CARD READER KEYBOARD DOOR RELEASE HOUR TEMPERED SCW ALUM H.M. G.H.M. I.G.H.M. PREFIN. O.H. O.H.G. CD HR. H.W. D.E. E.D.S. C.R. KY D.R. HR TEMP 3' - 8"16 GA. HOLLOW METAL KD FRAME - INTERIOR C7 A-100.00 E7 A-100.008"VARIESSEE WALL TYPES VARIES DOUBLE 20 GA. MTL STUD W/ NESTED CONTINUOUS 2X WD BLOCKING. JAMB ANCHOR. (TYP.) HM DOOR FRAME. SEE SCHEDULE. SILENCERS. REFER TO SCHEDULE. DOOR. REFER TO SCHEDULE.5/8"2"1/2" SEE WALL TYPES VARIES DOUBLE 20 GA. MTL STUD W/ NESTED CONTINUOUS 2X WD BLOCKING. JAMB ANCHOR. (TYP.) HM DOOR FRAME. SEE SCHEDULE. SILENCERS. REFER TO SCHEDULE. DOOR. REFER TO SCHEDULE.5/8"2"1/2"4"DISTANCE FROM DOOR EDGE TO FACE OF PERPENDICULAR WALL. WHERE APPLICABLE. DOOR HARDWARE A.DOUBLE ACTION • (3) DOUBLE-ACTION AUTO- CLOSING HINGES • KICKPLATE (BOTH SIDES) • PUSH PLATES BOTH SIDES • WALL/FLOOR STOP V.I.F.V.I.F.MATCH EX'GV.I.F.MATCH EX'GOF GRIDTO UNDERSIDEV.I.F. MATCH EX'G CLEAR ANONDIZED FRAMING CLEAR GLAZING FROSTED GLAZING, SIMILAR TO TLC. DUPLEX / DATA COMBINATION RECEPTACLE LOCATIONS IN CONTRACT. ( PROVIDE GFCI IN WET AREAS) VERIFY MOUNTING HEIGHTS AND FINAL LOCATIONS W/ OWNER ELECTRICAL SYMBOLS LEGEND SCALE: PROJECT NO: c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED PROJECT MANAGER: PROJECT ARCHITECT: PRODUCTION LEADER: PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE: THIS DRAWING IS THE PROPERTY OF CAOLO & BIENIEK ASSOCIATES, INC. THE RE-USE OR REPRODUCTION OF THIS DRAWING FOR ANY PURPOSE WHATSOEVER WITHOUT AN EXPRESSED WRITTEN AGREEMENT BETWEEN CAOLO & BIENIEK ASSOCIATES INC. AND THE USER IS STRICTLY PROHIBITED. RIGHTS TO USE THE INFORMATION ON THIS SHEET ARE NOT TRANSFERRED UNTIL PAYMENT HAS BEEN RECEIVED FOR SERVICES RENDERED. ANY RIGHTS SO GRANTED ARE NON- TRANSFERABLE TO OTHER PARTIES WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT OF CAOLO & BIENIEK ASSOCIATES, INC. A 1 B C D E F 2 3 4 5 6 7 8 A B C D E F 1 2 3 4 5 6 7 8 A-100.00 202133FLOOR PLANNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX MRRJH CE 1/4" = 1'-0"A-100.00 F1 FLOOR PLAN 1 1/2" = 1'-0"A-100.00 B7 KITCHEN WALL TYPE DOOR SCHEDULE DOOR # DOOR STYLE WIDTH HEIGHT THICKNESS DOOR MATERIAL DOOR FINISH GLAZING TYPE FRAME TYPE FRAME MATL. FRAME FINISH FIRE RATING HARDWARE COMMENTS 100 FG 3' - 0" 7' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN 101B F 3' - 0" 7' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN 102 N 3' - 0" 7' - 0" 1 3/4" HM PNT. TEMP. FR-1 HM PNT. NA A DOUBLE ACTION DOOR W/ VISION PANEL AND PUSH PLATES 103 F 3' - 0" 8' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN 104 F 3' - 0" 8' - 0" 1 3/4" - - - - - - - - EXISTING TO REMAIN 3" = 1'-0"A-100.00 C7 TYP. DOOR HEAD DETAIL 3" = 1'-0"A-100.00 E7 TYP. DOOR JAMB DETAIL 1/4" = 1'-0"A-100.00 B5 INTERIOR STOREFRONT ELEVATION COORDINATE NUMBER AND LOCATION OF NEW ELECT. / DATA RECEPTACLES WITH OWNER. EXISTING RECEPTACLES TO BE REPLACES WITH NEW TYPE. PROVIDE BLOCKING AS NEEDED FOR WALL MOUNTED EQUIPMENT. COORDINATE W/ KITCHEN PLANS.DATEDESCRIPTION WH RESILIENT FLOORING OVER CONCRETE. CARPET OVER CONCRETE. REDUCER STRIP, CONFIRM PROFILE DURING SUBMITTAL PROCESS. DOOR. REFER TO DOOR SCHEDULES FOR ADDITIONAL INFO. NOTE: WHERE REQUIRED, TRANSITION STRIPS SHALL BE CENTERED ON CENTERLINE OF DOOR IN THE CLOSED POSITION. 102 1547 SF 101 COFFEE SHOP & SPEAKEASY 274 SF 102 KITCHEN 53 SF 103 T.R. 53 SF 104 T.R. 101B 100 103 104 B5 A-100.00 NOTE: KITCHEN EQUIPMENT SHOWN FOR REFERENCE. SEE KITCHEN PLANS FOR MORE INFORMATION.28' - 7 1/4"28' - 0"19' - 7"15' - 5 1/2"8' - 7" 5' - 10" 12' - 9 1/4"12' - 7" CPT TILE LVT LVT E7 A-700.00 E7 A-700.00 E7 A-700.00 3' - 0"E5 A-700.00 CLG. CEILING CONC CONCRETE CPT CARPET TILE EX'G EXISTING FRP FIBER REINFORCED PLASTIC GWB GYPSUM WALL BOARD PNT PAINT VCT VINYL COMPOSITE TILE WC WALL COVERING FINISHES ABBREVIATION KEY 5MM LVT FLOORING OVER CONCRETE. CARPET OVER CONCRETE. NOTE: WHERE REQUIRED, TRANSITION STRIPS SHALL BE CENTERED ON CENTERLINE OF DOOR IN THE CLOSED POSITION. METAL EDGE STRIP FLUSH WITH LVT AND CARPET, SCHLUTER VINPRO-S OR EQ. FINISH LEGEND CODE DESCRIPTION MANUFACTURER STYLE COLOR COMMENTS CPT CARPET TILE 24" X 24" J&J FLOORING APERTURE II 7770 3106 NOISE INSTALL. METHOD TBD LVT LUXURY VINYL TILE 23.62" X 23.62" PATCRAFT 1313V CHARTERED 00590 ASTERICKS 20 MIL WEAR LAYER VSB 4"H VINYL STRAIGHT BASE TBD TRN FLOORING TRANSITION SCHLUTER L-ANGLE STRIP UNDERLAYMENT FLASHING TO LEVEL WC-1 WALLCOVERING WOLF GORDON HAVEN III ANTOINETTE SILK ALK 7-7550 CRIMSON SEATING AREA SIDE OF KITCHEN WALL AND WALL TBD WC-2 WALLCOVERING WOLF GORDON BALLARI MYLAR / STARDUST GOH 31885552 REVERSE HANG / RANDOM MATCH WC-3 WALLCOVERING WOLF GORDON THEORBO TBD STRAIGHT HANG / STRAIGHT MATCH WC-4 WALLCOVERING WOLF GORDON THEORBO TBD STRAIGHT HANG / STRAIGHT MATCH P-1 WALL PAINT TBD TBD LINEN FINISH P-2 WALL PAINT TBD TBD LINEN FINISH ACT ACOUSTICAL CEILING TILE TBD REPLACEMENT CEILING TILE GRID PNT ELECTROSTATIC PAINT TBD PAINT FOR EXISTING CEILING GRID BAR FINISHES COUNTERTOPS CAMBRIA OPTION 1: DELGATIE LUXURY SERIES +/- 2" THICK. STOOL SIDE EDGE EASED, OTHER EDGES SQUARE OPTION 2: BRITTANICCA WARM LUXURY SERIES BAR FRONT (VISIBLE AREA) FORMICA DECOMETAL M9424 COPPER PATINA BAR REAR (NON-VISIBLE FACE) TBD (POSSIBLY FORMICA BLACK RECYCLE KRAFT COORDINATE W/ EQUIPMENT PROVIDER MATT 9685-58 OR CHOCKOLATE WARP MATT 5881-58) SCALE: PROJECT NO: c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED PROJECT MANAGER: PROJECT ARCHITECT: PRODUCTION LEADER: PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE: THIS DRAWING IS THE PROPERTY OF CAOLO & BIENIEK ASSOCIATES, INC. THE RE-USE OR REPRODUCTION OF THIS DRAWING FOR ANY PURPOSE WHATSOEVER WITHOUT AN EXPRESSED WRITTEN AGREEMENT BETWEEN CAOLO & BIENIEK ASSOCIATES INC. AND THE USER IS STRICTLY PROHIBITED. RIGHTS TO USE THE INFORMATION ON THIS SHEET ARE NOT TRANSFERRED UNTIL PAYMENT HAS BEEN RECEIVED FOR SERVICES RENDERED. ANY RIGHTS SO GRANTED ARE NON- TRANSFERABLE TO OTHER PARTIES WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT OF CAOLO & BIENIEK ASSOCIATES, INC. A 1 B C D E F 2 3 4 5 6 7 8 A B C D E F 1 2 3 4 5 6 7 8 A-700.00 202133FINISHESNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX MRRJH CE ROOM FINISH SCHEDULE RM # ROOM NAME FLOOR MATERIAL FLOOR FINISH BASE NORTH WALL MAT'L. NORTH WALL FINISH EAST WALL MAT'L. EAST WALL FINISH SOUTH WALL MAT'L. SOUTH WALL FINISH WEST WALL MAT'L. WEST WALL FINISH COMMENTS 101 COFFEE SHOP & SPEAKEASY CONC. CPT., LVT VSB GWB WC GWB WC GWB WC GWB WC WINDOW TREATMENTS TBD; H.M. FRAMES, PAINT 102 KITCHEN CONC. LVT - GWB FRP GWB FRP GWB FRP GWB FRP BASE - INTEGRAL FRP; H.M. FRAME, PAINT. 103 T.R. CONC. EX'G EX'G GWB EX'G GWB EX'G GWB EX'G GWB EX'G 104 T.R. CONC. EX'G EX'G GWB EX'G GWB EX'G GWB EX'G GWB EX'G 1 1/2" = 1'-0"A-700.00 E5 TRANSITION - VCT TO CARPET 1/4" = 1'-0"A-700.00 F1 FLOOR PLAN DATEDESCRIPTION1 1/2" = 1'-0"A-700.00 E7 TRANSITION - LVT TO CARPET FLUSH CEILING KEY: SYMBOL RECESSED 2' X 2' LIGHT FIXTURES, REUSED / RELOCATED. DESCRIPTION SYMBOL DESCRIPTION ILLUMINATED EXIT SIGN, EX'G TO REMAIN NOTE: REFER TO MEP DRAWINGS AND CEILING SCHEDULES FOR ADDITIONAL INFORMATION RECESSED DOWNLIGHT FIXTURE, NEW (OR EX'G IF NOTED IN PLAN) 2' X 2' ACOUSTIC CEILING TILE GYPSUM CEILING WALL SCONCE FIXTURE LIGHT SWITCH W/ OCCUPANCY SENSOR (TYP.) LIGHT SWITCH (NO OCCUPANCY SENSOR) NOTE: REFER TO FINISHES PLAN A-100.00 FOR DUPLEX RECEPTACLE & DATA OUTLET LOCATIONS IN CONTRACT. VERIFY ALL MOUNTING HEIGHTS / LOCATIONS W/ OWNER. CEILING MOUNTED ILLUMINATED EXIT SIGN WITH ARROW AS SHOWN IN PLAN RECESSED WALL WASH FIXTURE EX'G GRID PROVIDE NEW, CLEANABLE SUSPENDED ACOUSTICAL CEILING TILES REUSED AND RELOCATE LIGHTING FIXTURES TIN CEILING (BLACK) SUSPENDED ACOUSTICAL CEILNG TILES, BLACK, TYP. OUTLINE OF BAR BELOW AREA OF SPECIALTY GRILLE CEILNG TBD. D D DE D D D DE D D D D D D D D DE A A A A A A X BAR LIGHTING TBD S S S S S D W W W W W W W D D D D D EX'G EX'G EX'G EX'G 3' - 0"3' - 0"3' - 0"D DE A.F.F. 2' x 2' ACT System 8' -6" A.F.F. 5/8" GWB SOFFIT 8' -0" EX'G GWB SOFFIT Type Manufacturer Catalog # Mounting Method # of Lamps Lamp Type Lamp Description Voltage Input Watts Line Comments LIGHTING SPECIFICATIONS A LITHONIA LIGHTING EPANL 2X2 3400LM 80CRI 30K MIN1 ZT MVOLT RECESSED 1 LED 32 UNV 32 REUSE / RELOCATE: DLC LISTED 3400 LUMEN FLAT PANEL WITH 0-10V DIMMING TO 1% D ACULUX INIT3 D 15LM 30K 80CRI 50D EZ1 MVOLT / RECESSED 1 LED 16 UNV 16 3IN BLACK BEVEL TRIM DOWNLIGHT WITH 1600 DELIVERED LUMENS WITH 0-10V DIMMING TO 1% NT3DBV BD BLSF / HB26ACULUX DE ACULUX INIT3 D 15LM 30K 80CRI 50D EZ1 MVOLT / RECESSED 1 LED 16 UNV 16 3IN BLACK BEVEL TRIM DOWNLIGHT WITH 1600 DELIVERED LUMENS WITH 0-10V DIMMING TO 1% NT3DBV BD BLSF / HB26ACULUX CONNECTED TO EMERGENCY LIGHTING INVERTER S SURFACE 1 LED SURFACE MOUNT INTERIOR WALL SCONCE FIXTURE W/ DIMMING TO 1%, TBD UC KELVIX SX-30K-300-24V/SX-TRX-1F-PAK-P/FML-2C-6/ULV96 LED UNDER BAR COUNTER / WORKSURFACE ILLUMINATION W ACULUX INITIA INT3 3" APERTURE LENSED WALLWASH FIXTURE RECESSED LED BLACK PAINT OR BLACK SPECULAR FINISH TBD X ISOLITE CORP. UEL-EM-G-1C2M-MTEBR CEILING 1 LED 3 UNV 3 EDGE LIT UNIVERSAL SINGLE AND DOUBLE FACE EXIT WITH GREEN LETTERS AND INTEGRAL EMERGENCY BATTERY BACK-UP SCALE: PROJECT NO: c 2019 CAOLO & BIENIEK ASSOCIATES, INC.ARCHITECT:OWNER:PROJECT:SHEET TITLE:SHEET NO:ISSUE DATE:AS INDICATED PROJECT MANAGER: PROJECT ARCHITECT: PRODUCTION LEADER: PEER REVIEWER:STAMPS:521 East StreetChicopee, MassachusettsCAOLO & BIENIEK ASSOCIATES, INC.ARCHITECTURE · PLANNING · INTERIOR DESIGN1.413.594.2800www.cbaarchitects.netNOTICE: THIS DRAWING IS THE PROPERTY OF CAOLO & BIENIEK ASSOCIATES, INC. THE RE-USE OR REPRODUCTION OF THIS DRAWING FOR ANY PURPOSE WHATSOEVER WITHOUT AN EXPRESSED WRITTEN AGREEMENT BETWEEN CAOLO & BIENIEK ASSOCIATES INC. AND THE USER IS STRICTLY PROHIBITED. RIGHTS TO USE THE INFORMATION ON THIS SHEET ARE NOT TRANSFERRED UNTIL PAYMENT HAS BEEN RECEIVED FOR SERVICES RENDERED. ANY RIGHTS SO GRANTED ARE NON- TRANSFERABLE TO OTHER PARTIES WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT OF CAOLO & BIENIEK ASSOCIATES, INC. A 1 B C D E F 2 3 4 5 6 7 8 A B C D E F 1 2 3 4 5 6 7 8 A-900.00 202133REFLECTEDCEILING PLANNoho Social CoffeeShop & Speakeasy9.24.21 Turning LeafCentersXX MRRJH CE 1/4" = 1'-0"A-900.00 F1 REFLECTED CEILING PLAN DATEDESCRIPTIONNOTE: EX'G GRID IN PUBLIC AREA TO BE ELECTROSTATICALLY PAINTED TO MATCH TILES. NOTE: PROVIDE (5) NEW EXTERIOR SCONCES, TYPE SL-1, AT WINDOWS, LOCATIONS TO BE CONFIRMED BY OWNER. 1. ROUGH-INS SHOWN ON THE ROUGH-IN DRAWINGS ARE FOR EQUIPMENT BEING SUPPLIED BY KEC ONLY. ADDITIONAL ROUGH-INS SHOWN OR NOT SHOWN ON THESE DRAWINGS FOR EQUIPMENT BEING RELOCATED, REUTILIZED OR SUPPLIED BY OTHERS WILL HAVE TO BE VERIFIED BY CORRESPONDING PRIME CONTRACTOR (EC, PC, MC, GC) PRIOR TO ROUGH-INS BEING INSTALLED. SINGER EQUIPMENT COMPANY WILL NOT BE RESPONSIBLE FOR THESE ROUGH-INS. 2. THE MECHANICAL PLANS ARE PREPARED AS AN ACCOMMODATION AND GUIDE ONLY, TO INDICATE MECHANICAL REQUIREMENTS NECESSARY TO OPERATE THE EQUIPMENT. DEVIATIONS FROM THE MECHANICAL WORK SHOWN ON THESE PLANS AND EXECUTION OF SUCH WORK IS WITHOUT RESPONSIBILITY OF SINGER EQUIPMENT COMPANY. 3. DATA ON THIS SHEET IS TO BE REVIEWED BY OWNER AND/OR ARCHITECT AND IS TO BE INCORPORATED INTO THE BUILDING MECHANICAL PLANS IN ACCORDANCE WITH LOCAL CODES. 4. OWNER AND/OR ARCHITECT IS TO SUBMIT THIS PLAN SET TO LOCAL HEALTH DEPARTMENT FOR APPROVAL UNLESS OTHERWISE SPECIFIED. 5. ALL EQUIPMENT BEING FURNISHED, PER THIS SET OF PLANS, BY KEC, HAS THE UNDERWRITERS' LABORATORIES AND NATIONAL SANITATION FOUNDATION SEALS OF APPROVAL. 6. KEC TO SET EQUIPMENT AT THE SITE IN ACCORDANCE WITH THESE PLANS AND TERMS OF CONTRACT WITH OWNER. 7. ALL PLUMBING, ELECTRICAL AND VENTILATION WORK, INCLUDING "ROUGH-IN" AND "FINAL CONNECTIONS" TO THE EQUIPMENT, IS TO BE PERFORMED BY OTHERS. IT IS NOT PART OF KEC CONTRACT UNLESS OTHERWISE SPECIFIED. 8. TO EXPEDITE AND ENSURE PROPER INSTALLATION OF COOKING EQUIPMENT, "ALL FINAL CONNECTIONS"ARE TO BE PERFORMED BY OTHERS AT THE SAME TIME THE KEC IS SETTING THE EQUIPMENT IN PLACE. 9. IF CONTRACTED, KEC SHALL FURNISH AND INSTALL ALL NECESSARY REFRIGERATION LINES FROM THE COMPRESSORS TO THE EVAPORATOR COILS IN THE WALK-IN BOXES. REFER TO MANUFACTURER'S FINAL APPROVED SPECIFICATIONS & DRAWINGS. 10. GC AND/OR MILLWORK PROVIDER TO FURNISH AND INSTALL RUBBER GROMMETS FOR ALL COUNTER TOP CUT OUTS MADE FOR MECHANICAL CONNECTIONS AS REQUIRED. 11. CONVENIENCE OUTLETS AND AREA FLOOR DRAINS TO BE LOCATED AND PROVIDED BY THE RESPECTIVE TRADES AND IN ACCORDANCE WITH LOCAL CODES. 12. FOOD SERVICE EQUIPMENT SHALL BE INSTALLED SO THAT EQUIPMENT CONFORMS TO AT LEAST ONE OF THE FOLLOWING: A. MOVEABLE EQUIPMENT IS PROVIDED WITH CASTERS (AND RESTRAINING DEVICES AS REQUIRED). B. FIXED EQUIPMENT IS SEALED TO WALLS, FLOORS, OR ADJACENT EQUIPMENT. C. FIXED FLOOR-MOUNTED EQUIPMENT IS INSTALLED WITH 6" CLEARANCE FROM THE FLOOR. 13. GC SHALL PROVIDE AND COORDINATE WITH KEC (AS REQUIRED) ALL BUILDING OPENINGS AND CONDITIONS (REFER TO PLANS FOR LOCATIONS, SIZES AND DETAILS), INCLUDING BUT NOT LIMITED TO: A. RECESSED FLOORS AND OPENINGS FOR INSTALLATION OF FLOOR TROUGHS AND WALK-IN COOLER(S) & FREEZER(S) ; B. OPENINGS FOR INSTALLATION OF CONTROL PANELS; C. OPENINGS THROUGH FINISHED CEILINGS AND (IF REQUIRED) THROUGH ROOF TO SERVICE ROOF-MOUNTED FOODSERVICE EQUIPMENT; D. STRUCTURAL SUPPORT TO HANG HOODS AND OTHER CEILING- SUPPORTED EQUIPMENT. E. PENETRATIONS THROUGH STRUCTURE AND CHASES (PVC OR EMT SLEEVE) FOR REMOTE REFRIGERATION LINES AND BEVERAGE LINES. ALL PENETRATIONS THROUGH STRUCTURE TO BE SEALED BY GC AS REQUIRED BY CODE. 14. IF CONTRACTED, KEC SHALL PROVIDE REMOVABLE ENCLOSURE PANELS FROM THE TOP OF THE WALK-IN COOLER(S) AND/OR FREEZER(S) AND EXHAUST HOODS TO FINISHED CEILING. CEILING HEIGHTS TO BE VERIFIED PRIOR TO FABRICATION. REFER TO MANUFACTURER'S FINAL APPROVED SPECIFICATIONS & DRAWINGS. 15. GC SHALL PROVIDE WALL BLOCKING IN WALLS, AS DETAILED IN THE FOODSERVICE SPECIAL CONDITIONS PLAN. 16. GC TO ENSURE ALL EQUIPMENT RUNS ABOVE FINISHED CEILING DO NOT INTERFERE WITH ANY CEILING HUNG EQUIPMENT SPECIFIED AND SHOWN ON THESE DRAWINGS. GENERAL NOTES GENERAL NOTES 1. THE INFORMATION SHOWN ON THE ELECTRICAL PLAN(S) IS FOR FOOD SERVICE EQUIPMENT ONLY AND THE RESPONSIBILITY OF THE GC/EC UNLESS OTHERWISE SPECIFIED. FOR ALL OTHER REQUIREMENTS, SUCH AS INTERIOR AND EXTERIOR LIGHTING, TOILET FACILITIES, EXHAUST FANS, WALL OUTLETS AND TELEPHONES, SEE ARCHITECTS AND ELECTRICAL ENGINEERING DRAWINGS. 2. EC TO DO ALL ROUGH-INS AND MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. EC TO FURNISH ALL TRIM, ACCESSORIES, DISCONNECTS, CONTACTORS, SWITCHES, RELAYS, ETC, AS REQUIRED. 3. ALL WIRING AND CONDUIT TO BE CONCEALED. 4. EC TO ACCOMMODATE ALL PREVAILING LOCAL ELECTRICAL CODES AS REQUIRED. 5. EC TO REFER TO ARCHITECTURAL AND ELECTRICAL ENGINEERING PLANS AND SPECIFICATIONS (BY OTHERS) FOR COMPLETE SCOPE OF WORK. 6. EC TO PROVIDE REQUIRED CONVENIENCE RECEPTACLES AS PER LOCAL CODE HAVING JURISDICTION AND PER OWNER'S NEEDS. 7. GFI RECEPTACLES ARE NOT RECOMMENDED FOR THE KITCHEN EQUIPMENT SHOWN ON THESE DRAWINGS. KITCHEN EQUIPMENT SHOULD PLUG INTO A NON-GFI DEDICATED RECEPTACLE FOR THAT PIECE OF EQUIPMENT. KEC WILL NOT BE HELD RESPONSIBLE FOR ANY SERVICE OR WARRANTY WORK RELATED TO KITCHEN EQUIPMENT THAT TRIPS A GFI RECEPTACLE. IT IS RECOMMENDED THE ELECTRICAL ENGINEER OR ELECTRICAL CONTRACTOR OBTAIN A VARIANCE IF CODES OR OTHER DRAWINGS FOR THIS PROJECT REQUIRE GFI RECEPTACLES FOR THE KITCHEN EQUIPMENT. GFCI BREAKERS ARE PREFERRED. 8. MOUNTING HEIGHTS GIVEN ARE TO CENTERLINE OF DEVICE UNLESS OTHERWISE NOTED. 9. FLOOR MOUNTED DEVICES ARE TO BE MOUNTED WITH A 5 3/4" MAXIMUM HEIGHT TO TOP OF BOX. 10. EC SHALL FURNISH ALL LABOR AND MATERIALS (INCLUDING, BUT NOT LIMITED TO, ALL CONTACTORS, RECEPTACLES, J-BOXES, SWITCHES, INTERWIRING, DISCONNECT SWITCHES, MOTOR STARTERS AND/OR TRANSFORMERS OR ANY OTHER ELECTRICAL DEVICE REQUIRED TO MAKE EQUIPMENT OPERATIONAL) TO MAKE FINAL CONNECTIONS FROM SERVICE ROUGH-INS TO EQUIPMENT AND INTERCONNECTIONS BETWEEN EQUIPMENT, WITH ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. GENERAL ELECTRICAL NOTES 11. ALL POWER CONNECTION POINTS UNDER EXHAUST HOODS ARE TO SHUTDOWN UPON FIRE SUPPRESSION SYSTEM ACTIVATION PER NFPA 96. EC TO FURNISH AND INSTALL SHUNT-TRIP BREAKERS FOR THESE CIRCUITS. 12. EC TO VERIFY, FURNISH AND INSTALL REQUIRED ELECTRICAL ROUGH-INS FOR ALL EXISTING, REUTILIZED AND NEW EQUIPMENT EQUIPMENT BEING SUPPLIED BY THE OWNER. KEC IS NOT RESPONSIBLE FOR THESE ROUGH-INS. 13. ALL 120 VOLT DUPLEX RECEPTACLES SHALL BE A MINIMUM OF 20.0 AMP CIRCUITS, UNLESS OTHERWISE NOTED. MOUNT ALL DUPLEX RECEPTACLES HORIZONTALLY WITH STAINLESS STEEL FACE PLATES, UNLESS OTHERWISE NOTED. 14. ALL EXPOSED CONDUIT SHALL BE SEALTIGHT OR EPOXY COATED FOR CLEANING TO COMPLY WITH LOCAL HEALTH CODES. EXPOSED METAL-CLAD CONDUIT IS NOT ACCEPTABLE. 15. EC TO INTERWIRE FIRE PROTECTION SYSTEM WITH BUILDING ALARM SYSTEM. 16. EC TO SUPPLY ALL NECESSARY CONTACTORS AND/OR SHUNT TRIP BREAKERS SO THAT ALL POWER TO ELECTRICAL EQUIPMENT BELOW EXHAUST HOODS WILL BE SHUT-OFF UPON ACTIVATION OF THE FIRE PROTECTION SYSTEM. 17. REMOTE PULL STATION SHALL BE PROVIDED AND INSTALLED BY FPC. EC SHALL PROVIDE WALL-MOUNTED OCTAGONAL JUNCTION BOX FOR REMOTE PULL STATION AND 1/2" EMPTY CONDUIT FROM PULL STATION TO FIRE SUPPRESSION SYSTEM . FPC TO FIELD VERIFY PULL STATION LOCATION WITH LOCAL FIRE AUTHORITIES. 18. EC TO INTERWIRE LIGHTS, SWITCHES AND DOOR-FRAME HEATERS FOR WALK- IN COOLER(S)/FREEZER(S). EC TO INTERWIRE CONDENSING UNIT WITH EVAPORATOR COILS IN WALK-IN COOLERS/FREEZERS. EC TO PROVIDE AND INSTALL HEAT TAPE AROUND CONDENSATE DRAIN LINES IN WALK-IN FREEZERS. 19. EC SHALL PROVIDE EMPTY JUNCTION BOX AND UNDER FLOOR CONDUIT AS NECESSARY BETWEEN POS TERMINAL LOCATION AND ADMINISTRATOR'S OFFICE. EC SHALL PROVIDE COMPUTER GRADE SEPARATE DEDICATED CIRCUIT FOR OWNERS POS TERMINAL. 20. EC SHALL INTERWIRE DISPOSER, DISPOSER CONTROLS AND SOLENOID VALVE PROVIDED BY KEC, PER MANUFACTURER'S SPECIFICATIONS. 21. IT IS RECOMMENDED THAT EC IS TO PROVIDE AT LEAST 50 FOOT CANDLES OF LIGHT AT ALL WORK SURFACES, ALL FOOD PREPARATION AND KITCHEN WORK AREAS, AND AT LEAST 20 FOOT CANDLES OF LIGHT IN ALL OTHER AREAS, LIGHT FIXTURES IN FOOD PREPARATIONS AREAS MUST BE SHIELDED. GENERAL ELECTRICAL NOTES GENERAL SPECIAL CONDITIONS NOTES 1. ARCHITECT AND GC TO ENSURE ALL WALLS ARE PROPERLY REINFORCED TO SUPPORT WALL MOUNTED EQUIPMENT. GC TO PROVIDE AND INSTALL ALL WALL BLOCKING, UNLESS OTHERWISE NOTED. 2. WALL BLOCKING TO BE 16 GA. GALVANIZED METAL. ALL WALL BLOCKING SHALL BE CONCEALED AND SECURELY ATTACHED TO FRAMING WITHIN WALLS (BEHIND DRY WALL AND/OR FINISHES). WALL BLOCKING LENGTHS SHOWN ARE MINIMUMS. GC TO EXTEND WALL BLOCKING TO NEXT STUD IN EACH DIRECTION IN STUD WALL CONSTRUCTION. ANY SITE-SPECIFIC CONDITIONS THAT REQUIRE DEVIATION FROM THESE INSTRUCTIONS, AND NOT COVERED IN PLAN NOTES, MUST BE COORDINATED WITH KEC PRIOR TO COMMENCEMENT OF WORK. GC TO USE METAL STUDS. 3. GC SHALL ENSURE ALL WALLS/CEILINGS ARE PROPERLY REINFORCED TO SUPPORT ALL WALL AND/OR CEILING SUPPORTED EQUIPMENT. GC TO PROVIDE INTERMEDIATE SUPPORTS TO BUILDING STRUCTURE ABOVE AS REQUIRED FOR EXHAUST HOODS. 4. GC SHALL VERIFY INSTALLATION HEIGHT OF FINISHED CEILING WITH FOOD SERVICE EQUIPMENT BELOW AS SHOWN. 5. GC SHALL PROVIDE HOLES, AND SLEEVES THROUGH ROOF, FLOOR(S), CEILING(S) AND WALLS FOR SODA LINES, BEER LINES, REFRIGERATION LINES AND UTILITIES. GC TO SEAL ALL PENETRATIONS IN ACCORDANCE WITH LOCAL FIRE AND BUILDING CODES. 6. GC SHALL PROVIDE 6" OR 8" DIAMETER CONDUIT AND CORE DRILLING TO RUN SODA AND BEER LINES (PROVIDED BY VENDOR) FROM SODA AND BEER SYSTEM (S) TO POINT(S) SHOWN FOR DISPENSING HEADS. ALL BENDS TO BE EASY SWEEPS (18" (450mm) RADIUS MIN.). CONDUIT TO RUN ON UNDERSIDE OF SLAB OR ABOVE FINISHED CEILING AS INDICATED AND SUPPORTED AS REQUIRED. HAVE ONLY ONE(1) 18" MINIMUM RADIUS SWEEP BEND(45° OR 90°) AT EACH END. CONDUIT TO BE CONSTRUCTED WITH INTERNALLY SMOOTH, LEAK TIGHT JOINTS. ALSO AN IN-LINE PULL BOX, AT LEAST 12" X 30" SHOULD BE PROVIDED FOR ANY STRAIGHT RUN IN EXCESS OF 100 FEET WITH AN ADDITIONAL BOX PROVIDED FOR EVERY 100 FEET OF RUN. A DIRECTIONAL CHANGE PULL BOX, AT LEAST 30" SQUARE SHOULD BE USED IN SITUATIONS WHERE MORE THAN TWO (2) 90° TURNS ARE REQUIRED IN A RUN. PROVIDE CARLON PV-DUIT PLUS SCHEDULE 40 CONDUIT AND FITTINGS, OR APPROVED EQUAL. PLUMBING PVC OR CAST IRON IS NOT ACCEPTABLE BUT EMT OR RIGID ELECTRICAL CONDUIT IS ACCEPTABLE IN THOSE JURISDICTIONS WHERE PVC IS NOT ACCEPTABLE. SEE TYPICAL CONDUIT DETAIL. 7. GC SHALL PROVIDE 2" (50 mm) DIAMETER CONDUIT (PVC, EMT OR OTHER MATERIAL REQUIRED BY CODE) FOR RUN OF COMPUTER GRADE CONDUIT. ALL BENDS TO BE EASY SWEEPS (18" (450mm) RADIUS MIN.), AS REQUIRED BY OWNER. 8. GC SHALL PROVIDE ALL CLEAR OPENINGS IN WALLS TO RECEIVE FOOD SERVICE EQUIPMENT. ALLOW 1/2" MINIMUM CLEARANCE ON EACH SIDE AND TOP(S) OF EQUIPMENT. GC TO COORDINATE WITH KEC ON CONSTRUCTION AND DELIVERY SCHEDULES. 9. REFRIGERATION CONTRACTOR TO SUPPLY AND INSTALL REFRIGERATION SUPPLY AND RETURN LINES. GENERAL CONTRACTOR TO COORDINATE WITH THE KEC AND REFRIGERATION CONTRACTORS. 10. WHEN SPECIFIED AND PART OF KEC SCOPE/CONTRACT, CORNER GUARDS TO BE 18-20 GUAGE S/S, 2" x 2" x 48", AND SECURED IN THE FOLLOWING MANNER: A. CORNER GUARDS SECURED TO S/S SURFACE ARE SECURED WITH "POP" RIVETS AND EDGES SEALED WITH SILICONE. CORNER GUARDS TO BEGIN AT TOP OF SANITARY COVED MOLDING AND EXTEND TO A MINIMUM OF 48" AFF. B. CORNER GUARDS SECURED TO FRP SURFACE ARE TO BE SECURED WITH CONTACT CEMENT AND EDGES SEALED WITH SILICONE. C. CORNER GUARDS ARE TO BE SUPPLIED AND INSTALLED BY KEC. D. GENERAL CONTRACTOR TO PROVIDE TRUE, CONSISTENT 90° ANGLES TO FACILITATE CORNER GUARD INSTALLATION. 11. WHEN SPECIFIED, S/S WALL CLADDING SHALL BE SECURED TO WALL SURFACE WITH CONTACT CEMENT AND EDGES ARE SILICONED. IF CONTRACTED, S/S WALL CLADDING AND STRIPS TO BE SUPPLIED AND INSTALLED BY KEC. 12. WHEN WALK-IN DEPRESSION IS SPECIFIED, GC TO PROVIDE DEPRESSION FROM ROUGH SLAB TO TOP OF FINISHED FLOOR TO RECEIVE WALK-IN BOX PANELS. SEE WALK-IN REFRIGERATOR & FREEZER DETAIL. 13. GC TO PROVIDE DEPRESSION FROM ROUGH GRATING. SEE FLOOR TROUGH AND GRATING DETAIL. 14. MANUFACTURER RECOMMENDS 750 CFM PER HP FOR AIR COOLEd COMPRESSORS AND 250 CFM PER HP FOR WATER COOLED COMPRESSORS FOR PROPER VENTLATION. 15. GC TO PROVIDE CORE DRILLING AND THERMAL BARRIER AS REQUIRED FOR RECESSED COOLER FLOORING. 16. GC TO PROVIDE CORE DRILLED PENETRATIONS IN FLOOR OR WALL SUFFICIENT TO ACCESS REFRIGERATION TUBING AND POTENTIAL DRAIN LINES FOR EACH REFRIGERATION ITEM. GC TO PROVIDE FIRE STOP SEALANT AS REQ'D BY LOCAL CODE. ROOF PENETRATIONS ARE TO BE THROUGH APPROVED PITCH POCKETS. (COORDINATE W/ ROOFING CONTRACTOR) SUBMIT REFRIGERATION PIPING SCHEMATIC TO REFRIGERATION RACK MFG. FOR REVIEW PRIOR TO ANY WORK COMMENCING ON SITE. NOTE :PROVIDE FOR "P" TRAPS IN OIL RETURN PIPING LAYOUT. ALL LINES TO BE INSULATED WITH "ARMA-FLEX" OR EQUAL INSULATION. 17. GC TO SUPPLY & INSTALL ALL ROOF CURBS & PLATFORMS IN ACCORDANCE WITH REFRIGERATION MANUFACTURER'S PRINTED INSTRUCTIONS. 18. GC TO COORDINATE FINAL LOCATION OF CONDENSING UNITS WITH CONDENSING UNIT EQUIPMENT SUPPLIER, ARCHITECT AND OWNER. 19. GC TO VERIFY WITH ARCHITECT AND STRUCTURAL ENGINEER THAT THE ROOF WILL SUPPORT THE CONDENSING UNITS IN THE FINAL LOCATIONS. 20. IF THE CONDENSING UNITS ARE LOCATED MORE THAN 25' AWAY FROM THE WALK-IN BOX, GC TO NOTIFY SUPPLIER OF CONDENSING UNIT EQUIPMENT SUPPLIER PRIOR TO INSTALLATION OF ROOF CURBS, PITCH POCKETS AND CONDENSING UNITS. 21. GC TO VERIFY REFRIGERATION LINE RUN QUANTITY & DIRECTION WITH OWNER/VENDOR. REFRIGERATION RUNS & STUBS IF DRAWN ARE FOR REFERENCE ONLY. KEC IS NOT RESPONSIBLE FOR ROUTE, QUANTITY OR LOCATION. GENERAL SPECIAL CONDITIONS NOTES GENERAL SPECIAL CONDITIONS NOTES 1. SEE FINAL APPROVED DETAILED MANUFACTURER HOOD AND EXHAUST DRAWINGS FOR COMMERCIAL KITCHEN VENTILATION SIZES. IT IS THE RESPONSIBILITY OF THE MECHANICAL ENGINEER TO ENSURE DUCT SIZING AND INSTALLATION REQUIREMENTS SATISFY LOCAL CODES. 2. IF CONTRACTED, KEC SHALL BE RESPONSIBLE FOR HANGING EXHAUST HOOD(S) AND MAKE-UP AIR PLENUM(S) IN PLACE AND MAKING THEM READY FOR FINAL CONNECTION. HVAC CONTRACTOR TO PROVIDE AND INSTALL GREASE AND SUPPLY DUCT FROM HOODS TO EXHAUST FOR HOODS, FANS AND MAKEUP AIR UNIT. WHEN TYPE 1 (GREASE) EXHAUST IS PRESENT, FPC SHALL SUPPLY ALL NECESSARY COMPONENTS FOR FULLY OPERATIONAL, UL-LISTED, WET CHEMICAL FIRE SUPPRESSION SYSTEM, INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND COMPLIANT WITH ALL REQUIRED NFPA AND LOCAL CODES. 3. MEP SHALL VERIFY EXHAUST & SUPPLY DUCT RUNS WITH HVAC CONTRACTOR, AND BE RESPONSIBLE FOR COORDINATION/REVISION OF CONNECTIONS WITH PROJECT ENGINEERS AND CONTRACTORS FOR ALL COMMERCIAL KITCHEN VENTILATION EQUIPMENT. FPC TO FIELD VERIFY FIRE SUPPRESSION SYSTEM PULL STATION LOCATION WITH LOCAL FIRE AUTHORITIES. 4. HVAC CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS TO MAKE FINAL CONNECTIONS FROM EACH DUCT CONNECTION, WITH ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. SEE MECHANICAL ENGINEERING PLANS AND SPECIFICATIONS (BY OTHERS) FOR COMPLETE SCOPE OF WORK. 5. IF CONTRACTED, ALL KITCHEN EQUIPMENT EXHAUST AND SUPPLY FANS AND CONTROLS ARE TO BE PROVIDED BY KEC UNLESS OTHERWISE NOTED. ROOFTOP EQUIPMENT SHALL BE RIGGED BY GC AND INSTALLED BY HVAC CONTRACTOR AND EC. 6. HEAT SENSOR FOR DUCTS SHALL BE PROVIDED BY HOOD EQUIPMENT SUPPLIER UNLESS OTHERWISE NOTED IN SPECIFICATIONS. HEAT SENSOR SHALL MEET THE REQUIREMENTS TO ACTIVATE EXHAUST FANS WHEN OPERATION OF COOKING EQUIPMENT OCCURS. 7. IT SHALL BE THE HVAC CONTRACTOR'S RESPONSIBILITY TO PERFORM ALL REQUIRED AIR BALANCING AND FINAL ADJUSTMENTS TO EXHAUST & MAKE-UP AIR SYSTEMS FOR FINAL BUILDING DEPT. APPROVAL. 8. MEP ENGINEER TO ENSURE ADEQUATE VENTILATION FOR PROPER HEAT REJECTION OF REFRIGERATION CONDENSING UNITS. GENERAL HVAC & KITCHEN VENTILATION NOTESGENERAL PLUMBING NOTES 1. THE INFORMATION SHOWN ON THESE PLUMBING PLANS IS FOR THE FOOD SERVICE EQUIPMENT ONLY AND THE RESPONSIBILITY OF THE GC/PC UNLESS OTHERWISE SPECIFIED. FOR OTHER REQUIREMENTS SUCH AS TOILET FACILITIES, AREA FLOOR DRAINS ETC., SEE ARCHITECTURAL AND PLUMBING ENGINEERING PLANS. 2. PC TO DO ALL ROUGH-INS AND MAKE ALL FINAL CONNECTIONS TO EQUIPMENT AND INTERCONNECTIONS BETWEEN EQUIPMENT. PLUMBER TO FURNISH ALL TRIM, ACCESSORIES, VALVES, PRESSURE REGULATORS, P-TRAPS, GREASE TRAPS, DRAIN LINES AND BACKFLOW PREVENTION SYSTEM DEVICES, ETC. ALL PREVAILING LOCAL PLUMBING CODES TO BE ACCOMMODATED. 3. SHUT-OFF VALVES ON THE INLET SIDE OF THE COLD AND HOT WATER LINES SERVING EACH PIECE OF EQUIPMENT, ARE TO BE FURNISHED AND INSTALLED BY THE PC. 4. IF WATER PRESSURE AT THE EQUIPMENT AREA EXCEEDS 50 POUNDS FLOW PRESSURE OWNER OR HIS CONTRACTOR MUST INSTALL A PRESSURE REDUCING VALVE ON BOTH THE MAIN HOT WATER AND COLD WATER SUPPLY LINES SERVICING THE AREA. 5. FLOW PRESSURE TO DISHWASHER (OR ITS AUXILIARY HOT WATER BOOSTER HEATER IF ONE IS USED) MUST NOT EXCEED 25 POUNDS. 6. GC/PC MUST PROVIDE AN ADEQUATE SUPPLY OF 140°F HOT WATER TO ALL COOKING EQUIPMENT, DISHWASHER/BOOSTER HEATER AND SCULLERY SINKS. 110°F HOT WATER IS TO BE PROVIDED TO ALL OTHER SINKS. 7. IF WATER EXCEEDS TEN GRAINS OF HARDNESS, OR EXCESSIVE LIME, IRON, ALKALINE, ETC. CONDITIONS ARE PRESENT, PROPER WATER CONDITIONING EQUIPMENT MUST BE INSTALLED ON THE MAIN WATER LINES SERVING THIS FOOD SERVICE FACILITY. ALL WATER CONDITIONING EQUIPMENT SHALL BE FURNISHED, INSTALLED AND MAINTAINED BY OTHERS. 8. USING PVC PIPING FOR DRAIN LINES FROM EQUIPMENT THAT DISCHARGES HOT WATER SUCH AS STEAMERS & DISHWASHERS MAY CAUSE THE PVC PIPING TO SOFTEN OR CRACK. IT IS RECOMMENDED THAT METAL (COPPER OR GALVANIZED) PIPING BE USED. 9. PC TO PROVIDE GREASE INTERCEPTOR(S) AS CODE REQUIRES. PLUMBER TO SIZE AND FURNISH GREASE INTERCEPTOR(S) PER SPECIFICATIONS. PLUMBER TO CHECK WITH LOCAL CODES TO DETERMINE WHAT EQUIPMENT IS TO BE PIPED THROUGH A GREASE TRAP. SEE PLUMBING ENGINEERING DRAWINGS AND SPECIFICATIONS (BY OTHERS) FOR DETAILS. 10. PC TO EXTEND ALL INDIRECT WASTE LINES FOR FOOD SERVICE EQUIPMENT TO THE NEAREST FLOOR DRAIN(S) OR FLOOR SINK(S) BY PC AS REQUIRED, UNLESS OTHERWISE SPECIFIED. 11. PC TO RUN LINES FOR DISHMACHINE(S) AND CONVEYOR(S) TIGHT TO EQUIPMENT TO INSURE MAXIMUM FLOOR TO EQUIPMENT CLEARANCE. 12. PC TO INSTALL MECHANICAL GAS SHUT OFF VALVE IN GAS MAIN FEEDING ALL COOKING EQUIPMENT PRIOR TO ANY TEES OR GAS LOOP FEEDING COOKING EQUIPMENT. MECHANICAL SHUT OFF VALVE TO BE INSTALLED IN ACCESSIBLE CEILING SPACE OR BELOW FLOOR WITH ACCESS TO VALVE. 13. WHEN SPECIFIED, PLUMBER SHALL PROVIDE AND RUN HOT WATER LINES FROM WATER WASH CONTROL PANEL(S) TO CONNECTION(S) SHOWN AT VENTILATOR(S). 14. PC TO PROVIDE FLOOR DRAINS AS PER LOCAL CODE HAVING JURISDICTION AND OWNER'S REQUEST. 15. PC IS TO REVIEW ALL CATALOG DATA PROVIDED BY THE KEC TO ESTABLISH THE NECESSARY GAS PRESSURE TO THE KITCHEN EQUIPMENT. IF GAS PRESSURE TO KITCHEN EQUIPMENT IS HIGHER THAN REQUIRED, A PRESSURE REGULATOR IS TO BE PROVIDED BY THE PLUMBING CONTRACTOR OR BY THE GAS COMPANY. THE GAS PRESSURE REGULATOR MUST BE INSTALLED PRIOR TO THE GAS FEEDING ANY KITCHEN EQUIPMENT. EXCESSIVE GAS PRESSURE TO THE EQUIPMENT CAN DAMAGE THE EQUIPMENT AND CAUSE PERSONAL INJURY. 16. INTERCONNECTIONS BETWEEN BOOSTER HEATER AND DISHWASHER, AS WELL AS GENERATOR AND STEAM EQUIPMENT TO BE PROVIDED BY THE PLUMBING CONTRACTOR. 17. PC TO VERIFY, FURNISH AND INSTALL REQUIRED PLUMBING ROUGH-INS FOR ALL EXISTING,RE-UTILIZED AND NEW EQUIPMENT BEING SUPPLIED BY THE OWNER. KEC IS NOT RESPONSIBLE FOR THESE ROUGH-INS. 18. MANUFACTURERS OF GAS APPLIANCES REQUIRE A 7" WC AT THE POINT OF CONNECTION. 19. PC TO PROVIDE A WATER CONNECTION TO BYPASS WATER FILTER CONNECTIONS SO THAT WATER FILTERS MAY BE TEMPORARILY BYPASSED. 20. KEC PROVIDES WATER FILTER INFORMATION FOR REFERENCE ONLY. FINAL WATER CONNECTION SPECIFICATION TO BE VERIFIED WITH SCOPE OF USE, APPLICATION, ZIP CODE AND WATER QUALITY TESTING. GC/PC TO VERIFY FINAL SPECIFICATION AND LOCATION IN FIELD. KEC IS NOT RESPONSIBLE FOR RE-SIZING OR RELOCATION OF WATER FILTERS DUE TO SCOPE OF USE, APPLICATION, WATER QUALITY OR FIELD CONDITIONS. 21. PC TO SUPPLY & INSTALL ALL GAS, WATER & DRAINS REQUIRED BY MAKE-UP AIR SYSTEM. ALL SERVICES TO HAVE SHUT-OFF VALVES AT UNITS. 22. EXPOSED PIPING RUNS SHALL BE AS SHORT AS POSSIBLE. 23. GAS & WATER QUICK DISCONNECTS, WHEN SPECIFIED BY KEC, SHALL BE PROVIDED BY KEC. INSTALLATION SHALL BE BY THE PLUMBING CONTRACTOR. 24. PC SHALL INSTALL SOLENOID VALVE AND VACUUM BREAKER PRIOR TO WATER INLET OF DISPOSER (WHEN SPECIFIED). GENERAL PLUMBING NOTES A -AMPS AFC -ABOVE FINISHED CEILING AFF -ABOVE FINISHED FLOOR AV -AUDIO-VISUAL BTC -BRANCH TO CONNECT BTU -BRITISH THERMAL UNIT CFM -CUBIC FEET PER MINUTE CHWR -CHILLED WATER RETURN CHWS -CHILLED WATER SUPPLY CP -CORD & PLUG CO -CONVENIENCE OUTLET CR -CONVENIENCE RECEPTACLE c, CW -COLD WATER DFA -DOWN FROM ABOVE DN -DOWN DR -DUPLEX RECEPTACLE DW -DIRECT WASTE d, DRN -DRAIN DS -DISCONNECT SWITCH EC -ELECTRICAL CONTRACTOR EMT -ELECTRIC METAL TUBING EOF -ELECTRICAL OUTLET IN FLOOR fd, FD -FLOOR DRAIN ffd, FFD -FUNNEL FLOOR DRAIN fs, FS -FLOOR SINK FSEC -FOODSERVICE EQUIPMENT CONTRACTOR FP -FIRE PULL BOX FPC -FIRE PROTECTION CONTRACTOR fw, FW -FILTERED WATER G,g -GAS GC -GENERAL CONTRACTOR GFI -GROUND FAULT INTERCEPT GT -GREASE TRAP GU -GENERAL USE HP -HORSE POWER HVAC -HEATING/VENTILATION /AIR CONDITIONING ABBREVIATIONS h, HW -HOT WATER ID -INSIDE DIAMETER IPS -IRON PIPE SIZE IW -INDIRECT WASTE JB -JUNCTION BOX KEC -KITCHEN EQUIPMENT CONTRACTOR KW -KILOWATTS LP -LIQUID PROPANE MEP -MECHANICAL,ELECTRICAL & PLUMBING ENGINEER MT -MOUNT MTD -MOUNTED NIC -NOT IN CONTRACT NTS -NOT TO SCALE NSOD -NOT SHOWN ON DRAWING OD -OUTSIDE DIAMETER OOW -OUT OF WALL PC -PLUMBING CONTRACTOR PH -PHASE POS -POINT OF SALE PSI -POUNDS PER SQUARE INCH PRP -PRESSURE RELIEF PORT RECEP -RECEPTACLE RPM -REVOLUTIONS PER MINUTE S -STEAM S/S -STAINLESS STEEL SD -SMOKE DETECTOR SDFA -STUB DOWN FROM ABOVE SOOW -STUB OUT OF WALL SP -STATIC PRESSURE SR -SINGLE RECEPTACLE SW -SWITCH V -VOLTAGE VIF -VERIFY IN FIELD W -WATTS W/-WITH WC -WATER COLUMN xxx x ROUGH-IN NUMBER DETAIL DRAWING REFERENCE ELECTRIC STUB 120V SINGLE RECEPTACLE 120V DUPLEX RECEPTACLE 120V QUADPLEX RECEPTACLE 208V RECEPTACLE SWITCH ELECTRIC SYMBOLS J D JBOX DATA LINES DISCONNECT SWITCH CONDUIT DC01 120V 1PH DUPLEX CONVENIENCE OUTLET AFF HT PER PLAN. DC02 208V 1PH DUPLEX CONVENIENCE OUTLET AFF HT PER PLAN. xxx x PLUMBING SYMBOLS ROUGH-IN NUMBER DETAIL DRAWING REFERENCE GAS COLD WATER HOT WATER DRAIN FLOOR DRAIN FLOOR SINK EQUIPMENT INDIRECT WASTE FUNNEL FLOOR DRAIN CHILLED WATER SUPPLY & RETURN XXX X S C R ROUGH-IN NUMBER DETAIL DRAWING REFERENCE SODA CONDUIT, LINES, BUNDLE CHILLED DRINKING WATER LINE REFRIGERATION LINES S/S CORNER GUARD S/S WALL CLADDING WALL BACKING SPECIAL CONDITIONS SYMBOLS B BEER CONDUIT, LINES, BUNDLE w WINE CONDUIT, LINES, BUNDLE 3'-6" 3'-6"1 WALL SHELVING WALL BLOCKING DETAIL. NOT TO SCALE 3'-0" 4'-0"3 PRE-RINSE BRACKET WALL BLOCKING DETAIL. NOT TO SCALE 1'-8" 5'-6"4 MOP SINK & SHELVES WALL BLOCKING DETAIL. NOT TO SCALE 2'-0" 6'-0"2 HAND SINK WALL BLOCKING DETAIL. NOT TO SCALE 4'-0" 4'-0"5 WATER FILTER WALL BLOCKING DETAIL. NOT TO SCALE DIM ADIM B6 AS NOTED ON PLAN WALL BLOCKING DETAIL. NOT TO SCALE 7 S/S CORNER GUARDS & ENCLOSURE STRIPS NOT TO SCALE WALK-IN WALL S/S CORNER ENCLOSURE GUARD WALL WALL S/S CORNER GUARD 8 S/S WALL PANELS NOT TO SCALE SEAL JOINTS S/S END CAP VERTICAL GRAIN VERIFY SCOPE, AND LOCATIONS WITH OWNER AND ARCHITECT ADHERE S/S FLASHING TO WALL W/ FULL BED OF HEAT RESISTANT MASTIC. VOIDS AND FLEXING OF METAL ARE NOT ACCEPTABLE 1-1/2" 9 TROUGH DETAIL PLUMBING/SPECIAL CONDITIONS UTILITY DETAIL. NOT TO SCALE QUARRY TILE AND SETTING BED BY G.C. FILL AFTER SET IN PLACE BLOCK OUT AS SHOWN ON PLAN DRAIN PIPE BY PC NOTE: SEE PLUMBING DRAWING FOR DRAIN LOCATION. FOR SINGLE DRAIN TROUGHS DRAIN TO BE DIRECTLY IN CENTER OF PAN. CAULK BY PC 10 BEVERAGE CONDUIT SPECIAL CONDITIONS UTILITY DETAIL. NOT TO SCALE CEILING EASY SWEEP ELBOWS 24" RADIUS 18" MIN. (DO NOT USE STD. 90 DEG. ELBOWS. (TYP.) BEVERAGE SYSTEM 4" MIN. ABOVE FINISHED FLOOR 6" DIA. PVC OR EMT CONDUIT. PC &GC TO VERIFY REQUIREMENTS WITH LOCAL CODES AND SODA SYSTEM SUPPLIER BEVERAGE LINES CONDUIT REQUIREMENTS: 1. 6" OR 8" PVC OR EMT CONDUIT. PC/GC TO VERIFY SIZE WITH BEVERAGE SUPPLIER. 2. 4" MIN., 6" MAX. STUB-UP ABOVE FINISHED FLOOR. 3. 24" RADIUS (18" MIN.) RADIUS) EASY SWEEP ELBOWS ONLY. 4. CONDUIT MUST BE WATER TIGHT AND PITCHED BACK TO BEVERAGE SYSTEM. (1/8" PER FOOT SLOPE). VERIFY BEVERAGE CONDUIT TO RUN OVERHEAD OR BELOW. 11 QUICK DISCONNECT HOSE DETAIL PLUMBING UTILITY DETAIL. NOT TO SCALE RESTRAINT CABLE TO BE INSTALLED TO PREVENT GAS HOSE FROM BEING PULLED LOOSE FROM WALL. ADJUST CABLE TO SHORTER LENGTH THAN THAT OF THE GAS HOSE. INSTALL OTHER END OF RESTRAINT CABLE TO MOBILE COOKING EQUIPMENT. GAS SUPPLY MOBILE COOKING EQUIPMENT HOSE REEL 12 HOSE REEL DETAIL PLUMBING UTILITY DETAIL. NOT TO SCALE 1/2" NPT FLEX HOSE 1/2" NPT VACUUM BREAKER 1/2" NPT PIPING BY PC 1/2" NPT SHUT OFF VALVE MIXING VALVE 1/2" NPT PIPING BY PC CHECK VALVES 3/8" BLEEDER LINE BY PC OPTIONAL BLEEDER VALVE BY PC 7'-0" 4'-0" 6 " 8" 13 FLOOR MTD RECEPTACLE ELECTRIC UTILITY DETAIL. NOT TO SCALE ELECTRICAL CONDUIT STUB UP CONCRETE SLAB AND/OR FLOOR 5-3/4" TOP OF BOX MAX.14 SNEEZE GUARD HEAT AND/OR LIGHT WIRING DETAIL ELECTRIC UTILITY DETAIL. NOT TO SCALE HEAT AND/OR LIGHT FOOD SHEILD SUPPORT COUNTER/ MILLWORK (BY OTHERS) J.BOX (TYP.) (BY OTHERS) HEAT CONTROLLER MOUNTED IN BOX (BOX BY OTHERS) FOR GENERAL REFERENCE. SEE FINAL MANUFACTURERS SPECIFICATION/INSTALLATION DETAILS BALLAST BOX SUPPLY POWER (TYP.) (BY OTHERS) LIGHT SWITCH MTD IN A BOX (BOX BY OTHERS) NOTE: E.C. TO IDENTIFY PROPER LEG OF FOOD SHEILD FOR THE LIGHT AND/OR HEAT WIRING PRIOR TO WIRING TO SWITCH AND/OR CONTROLLER. 15 WALK-IN DETAIL: WALK-IN PLACED ATOP SLAB/SUB FLOOR W/ TILE FLOOR IN WALK-IN COOLER AND/OR TILE TERMINATING INTO WALK-IN PANEL SPECIAL CONDITIONS DETAIL. NOT TO SCALE THESE ARE TYPICAL WALK-IN CROSS SECTIONS FOR WALK-INS INSTALLED WITHOUT A DEPRESSED SLAB. PLEASE NOTE THAT THESE CROSS SECTIONS ARE FOR REFERENCE ONLY AND MAY NOT BE APPLICABLE FOR THIS PARTICULAR PROJECT. PLEASE SEE FINAL APPROVED MANUFACTURERS DRAWINGS. SECTION THRU WALK-IN COOLER DOOR SECTION THRU WALK-IN COOLER PARTITION OR EXTERIOR WALK-IN PANEL SECTION THRU WALK-IN COOLER/FREEZER DOOR W/ RAMP AND INSULATED FLOOR SECTION THRU WALK-IN COOLER/FREEZER DOOR W/ STEP UP AND INSULATED FLOOR SECTION THRU WALK-IN COOLER/FREEZER PANEL W/ INSULATED FLOOR AGAINST BUILDING WALL WALK-IN COOLER DOOR INTERIOR OR EXTERIOR WALL PANEL PERIMETER VINYL SCREED SECURED TO CONCRETE FLOOR FLOOR SCRUBBER TILE AND SETTING BED BY GC HEATER CHANNEL /THRESHOLD CONCRETE SLAB OR SUB FLOOR BY GC WATERPROOF MEMBRANE BY IF REQUIRED BY GC WALK-IN WALL PANEL (4" TYP.) WALK-IN WALL FLOOR SECTION (4" TYP.) COVED TILE TOE BASE BY GC TILE AND SETTING BED BY GC BUILDING WALL HEATER CHANNEL /THRESHOL D WALK-IN FLOOR SECTION (4" TYP.) WALK-IN COOLER/FREEZER DOOR 1" CLEAR INTERIOR RAMP COVED TILE TOE BASE INSIDE & OUT BY GC WALK-IN COOLER/FREEZER DOOR WALK-IN WALL PANEL (4" TYP.) PLEASE NOTE THAT THE DETAILS SHOWN ON THIS PAGE ARE FOR GENERAL REFERENCE ONLY AND MAY NOT BE APPLICABLE FOR THIS PARTICULAR PROJECT. FSEC SHEET LIST Sheet Number Sheet Name FS0.00 Notes, Symbols & Details FS1.10 Equipment & Schedule FS1.20 Plumbing Rough-in Plan FS1.30 Electric Rough-in Plan FS1.40 Special Conditions Plan FS1.50 Equipment Elevations FS1.51 Equipment Elevation DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV 1/4" = 1'-0" FS0.00 Notes, Symbols & Details 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06- 11 -21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM 18" X 36" 18" X 20"18" X 20"18" X 20"24"24"36"W X 24"D18" X 36" 18" X 48" 18" X 36"36"W X 24"D36"W X 24"D18" X 48"72"W X 30"D18" X 36" 18" X 36"18" X 36"24" X 36"24" X 36" FS1.51 4 FS1.50 2 4 2 SECURE SHELVING DISH REFRIG1-DOOR REFRIG FREEEZER DRY STORAGE PREP SINK W/ POT RACK H.S. MOP / MOP BUCKET / CHEMICAL STORAGE UC DISH MACHINE TRASH POS 71 72 3 ADA TRANSACTION COUNTER/ ADA SEATING COUNTER 3 TRASH TURBO CHEF PANINI WALL CONVECTION W/ SHELF RACK 185"102"PREP COCKTAIL STATION GLASSES MUG FROSTER COCKTAIL STATION GLASSES REFRIG WINE ICE KOLD- DRAFT REFRIG GLASS- WASH WINE REFRIG234"99" 114"264"1231512 14 11 13 6 6 6 8 8 7 18 23 23 25 1922 21 20 24 30 29 28 36 35 33 41 42 43 44 42 41 43 45 51 52 53 54 55 52 51 67 66 65 64 63 62 61 34 50 FILTER BAKERY CASE 56 68 H.S. DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV 1/4" = 1'-0" FS1.10 Equipment & Schedule 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06 -11-21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM SINGER EQUIPMENT IS NOT RESPONSIBLE FOR UTILITY AND ROUGH-IN INFORMATION FOR EQUIPMENT THAT IS SUPPLIED BY OTHERS. ARCHITECT, EC, PC, GC TO VERIFY OWNER SUPPLIED EQUIPMENT AND EQUIPMENT SUPPLIED BY OTHERS. EQUIPMENT SCHEDULE ITEM #QTY DESCRIPTION Manufacturer Model EQUIPMENT REMARK 1 1 Reach-In Refrigerator Per Specification Per Specification 2 1 Reach-In Refrigerator Per Specification Per Specification 3 1 Reach-In Freezer Per Specification Per Specification 4-5 1 Spare Number 6 3 Mobile Work Table Fabricator Fabrication 7 1 Secure Shelving Unit Per Specification Per Specification 8 2 Storage Shelving Unit Per Specification Per Specification 9-10 1 Spare Number 11 1 Mop Sink Fabricator Fabrication 12 1 Service Sink Faucet T&S Brass B-0655-BSTP WALL BACKING BY G.C. 13 1 Mop Bucket By Owner By Owner 14 1 Mop Holder Fabricator Fabrication WALL BACKING BY G.C. 15 2 Wire Wall Shelving Per Specification Per Specification WALL BACKING BY G.C. 16-17 1 Spare Number 18 1 Mobile Rack Per Specification Per Specification 19 1 Three-Bowl Sink Fabricator Fabrication 20 1 Faucet Per Specification Per Specification 21 1 Undercounter Dishwasher NIC By Others UL-100 NIC BY OTHERS; LOW-TEMP; VERIFY w/ OWNER 22 1 Undercounter Trash Can By Owner By Owner 23 4 Wire Wall Shelving Per Specification Per Specification WALL BACKING BY G.C. 24 1 Hand Sink Fabricator Fabrication WALL BACKING BY G.C. 25 1 Towel and Soap Dispenser NIC By Others NIC By Others WALL BACKING BY G.C. 26-27 1 Spare Number 28 1 Prep Sink Fabricator Fabrication 29 1 Faucet Per Specification Per Specification 30 1 Wall Shelf w/ Pot Rack Advance Tabco PS-12-36 WALL BACKING BY G.C. 31-32 1 Spare Number 33 1 Mobile Work Table Fabricator Fabrication 34 1 Convection Oven Winco ECO-500 VENTLESS; WALL-MOUNTED 35 1 Panini Warmer Waring WDG250 36 1 Rapid-Cook Oven TurboChef ECO-950 VENTLESS 37-40 1 Spare Number 41 2 Undercounter Trash Can By Owner By Owner 42 2 Cocktail Station Krowne Metal KR24-MX60-10 43 2 Glass Rack Storage Cabinet Krowne Metal KR24-S18 44 1 Mug Froster Krowne Metal KR24-MF18 45 1 Undercounter Refrigerator Continental BB24NGD 46-49 1 Spare Number 50 1 Combination Water Filter System PENTAIR EV9329-44 MOUNT HIGH NEAR CEILING; WALL BACKING BY G.C.; SERVICES BACKBAR EQUIPMENT 51 2 Undercounter Refrigerator Continental BB24NGD 52 2 Undercounter Wine Reserve Summit SCR60BLX 53 1 Undercounter Ice Machine Scotsman UC2024MA-1 54 1 Undercounter Ice Machine Kold-Draft SC201 55 1 Undercounter Glasswasher Jackson WWS DELTA 1200 56 1 Undercounter Hand Sink Krowne Metal KR24-12ST w/ SOAP & TOWEL DISPENSER 57-60 1 Spare Number 61 1 Drink Blender VitaMix QUIET ONE 62 1 Bean Grinder Mahlkonig EK43 63 1 Drop-In Dump Sink Per Specification Per Specification w/ FAUCET & SIDE SPLASHES 64 1 Bean Grinder Nuova Simonelli MYTHOS II GRAV 65 1 Pitcher Rinser Rhino RHPR600 66 1 Espresso Machine Slayer EP 2-GROUP 67 1 Cold Brew Coffee Dispenser Cornelius NitroPro 68 1 Countertop Ambient Display Case Per Specification Per Specification 69-70 1 Spare Number 71 1 POS nic by others nic by others 72 1 POS PRINTER nic by others nic by others xxx x PLUMBING SYMBOLS ROUGH-IN NUMBER DETAIL DRAWING REFERENCE GAS COLD WATER HOT WATER DRAIN FLOOR DRAIN FLOOR SINK EQUIPMENT INDIRECT WASTE FUNNEL FLOOR DRAIN CHILLED WATER SUPPLY & RETURN19"9"87"9"52"96"16" 42 42 42 42 42 44 43 43 4211"13" 12 11 15"15"28 29 13" 32"30"18"20 19 21 24 21 20" 22" 50 50 36"108"65 66 63 53 54 55 24"27"24"30"56 66 65 63 55 54 53 15"24"8"28"67 14" 22" PC TO EXTEND FILTERED CW OUT TO BAR AREA 101" 114" PLUMBING ROUGH-IN SCHEDULE ITEM #QTY DESCRIPTION CW SIZE CW RI HT (AFF)HW SIZE HW RI HT (AFF) DW CONN SIZE DW RI HT (AFF)IW CONN SIZE PLUMBING REMARKS 11 1 Mop Sink 2" 2" PC To Cut Down Drain Pipe As Required 12 1 Service Sink Faucet 1/2" 18" 1/2" 18"PC TO BTC 19 1 Three-Bowl Sink 1 1/2" PC TO BTC. PC TO EXTEND IW TO FLOOR RECEPTACLE AND/OR GREAS TRAP. PC TO VERIFY WITH LOCAL CODE. 20 1 Faucet 1/2" 18" 1/2" 18"PC TO BTC 21 1 Undercounter Dishwasher 1/2" 12"5/8" PC TO BTC; PC TO EXTEND FLEX. IW TO FLOOR RECEPTACLE. FASTEN AND LEAVE AIR GAP. 24 1 Hand Sink 1/2" 16" 1/2" 16" 1 1/2" 21" PC TO BTC 28 1 Prep Sink 2" PC TO BTC; PC TO EXTEND IW TO FLOOR RECEPTACLE 29 1 Faucet 1/2" 16" 1/2" 16"PC TO BTC 42 2 Cocktail Station 1/2" 12" 1/2" 12"1" (2) CW REQUIRED; (5) IW REQUIRED; PC TO EXTEND IW TO FLOOR RECEPTACLE 43 2 Glass Rack Storage Cabinet 1" PC TO EXTEND IW TO FLOOR RECEPTACLE 44 1 Mug Froster 1" PC TO EXTEND IW TO FLOOR RECEPTACLE 50 1 Combination Water Filter System 3/4" 90"PC TO EXTEND FILTERED CW FROM FILTER TO ITEM #'s 53, 54, 66 & 67 53 1 Undercounter Ice Machine 1/2" 12"3/4" FILTERED CW; PC TO EXTEND IW TO FLOOR RECEPTACLE 54 1 Undercounter Ice Machine 1/2" 12"3/4" FILTERED CW; PC TO EXTEND IW TO FLOOR RECEPTACLE 55 1 Undercounter Glasswasher 1/2" 12" 1/2" 12"1 1/2" PC TO EXTEND IW TO FLOOR RECEPTACLE 56 1 Undercounter Hand Sink 1/2" 10" 1/2" 10" 1 1/2" 14" 63 1 Drop-In Dump Sink 1/2" 16" 1/2" 16"1 1/2" PC TO EXTEND IW TO FLOOR RECEPTACLE 65 1 Pitcher Rinser 1/2" 18"3/4" PC TO EXTEND IW TO FLOOR RECEPTACLE 66 1 Espresso Machine 1/2" 48"1" FILTERED CW; PC TO EXTEND IW TO FLOOR RECEPTACLE 67 1 Cold Brew Coffee Dispenser 1/2" 48"FILTERED CW DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV 1/4" = 1'-0" FS1.20 Plumbing Rough-in Plan 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06 -11-21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM 24"48" 48"J J38"HORIZ38"HORIZ24" D 24" D J J48" 48" xxx x ROUGH-IN NUMBER DETAIL DRAWING REFERENCE ELECTRIC STUB 120V SINGLE RECEPTACLE 120V DUPLEX RECEPTACLE 120V QUADPLEX RECEPTACLE 208V RECEPTACLE SWITCH ELECTRIC SYMBOLS J D JBOX DATA LINES DISCONNECT SWITCH CONDUIT DC01 120V 1PH DUPLEX CONVENIENCE OUTLET AFF HT PER PLAN. DC02 208V 1PH DUPLEX CONVENIENCE OUTLET AFF HT PER PLAN. DCO1 82"40"40" 3 2 1 96"21 42"18"8"8"14"36 35 34 DCO1 DCO1 84"50"90"DCO1 DCO1 RETRACTABLE DROP CORD (VERIFY w/ OWNER) 45 48"32"40"22"30"24"18"51 52 53 54 55 52 5182"108"22"DCO1 DCO1 12"12" 72 7132"67 22"32"26"12"30"54"66 64 62 61 DCO1 DCO1 142" DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV 1/4" = 1'-0" FS1.30 Electric Rough-in Plan 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06 -11-21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM ELECTRIC ROUGH-IN SCHEDULE ITEM #QTY DESCRIPTION VOLTS PHASE AMPS CONN TYPE ELEC RI HT (AFF)ELECTRICAL REMARKS 1 1 Reach-In Refrigerator 120 V 1 2.3 A Cord & plug 48" 2 1 Reach-In Refrigerator 120 V 1 5.5 A Cord & plug 48" 3 1 Reach-In Freezer 120 V 1 10.5 A Cord & plug 48" 21 1 Undercounter Dishwasher 120 V 1 12.0 A Cord & plug 24" NIC BY OTHERS. EC TO VERIFY OWNERS SPEC. 34 1 Convection Oven 120 V 1 13.3 A Cord & plug 66" 35 1 Panini Warmer 120 V 1 15.0 A Cord & plug 48" 36 1 Rapid-Cook Oven 208 V 1 20.0 A Cord & plug 48" NEMA L6-20 45 1 Undercounter Refrigerator 120 V 1 2.5 A Cord & plug 24" 51 2 Undercounter Refrigerator 120 V 1 2.5 A Cord & plug 24" 52 2 Undercounter Wine Reserve 120 V 1 0.8 A Cord & plug 24" 53 1 Undercounter Ice Machine 120 V 1 7.8 A Cord & Plug 24" 54 1 Undercounter Ice Machine 120 V 1 6.0 A Direct 24" 55 1 Undercounter Glasswasher 208 V 1 15.0 A Direct 24" 61 1 Drink Blender 120 V 1 15.0 A Cord & plug 48" 62 1 Bean Grinder 120 V 1 11.0 A Cord & Plug 48" 64 1 Bean Grinder 120 V 1 10.0 A Cord & Plug 48" 66 1 Espresso Machine 220 V 1 24.1 A Direct 48" 67 1 Cold Brew Coffee Dispenser 120 V 1 5.0 A Direct 48" 71 1 POS 120 V 1 15.0 A Cord & Plug 24" PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT W/ ISOLATED GROUND & (2) DATA LINE (CAT 5). ROUGH-IN HEIGHT PER PLAN 72 1 POS PRINTER 120 V 1 5.0 A Cord & plug 24" PROVIDE DUPLEX RECEPTACLE ON DEDICATED CIRCUIT W/ ISOLATED GROUND & (2) DATA LINE (CAT 5). ROUGH-IN HEIGHT PER PLAN. XXX X S C R ROUGH-IN NUMBER DETAIL DRAWING REFERENCE SODA CONDUIT, LINES, BUNDLE CHILLED DRINKING WATER LINE REFRIGERATION LINES S/S CORNER GUARD S/S WALL CLADDING WALL BACKING SPECIAL CONDITIONS SYMBOLS B BEER CONDUIT, LINES, BUNDLE w WINE CONDUIT, LINES, BUNDLE WALL BACKING 24" AFF TO CEILING (VERIFY w/ OWNER) 186"72"54" WALL BACKING 24" AFF TO 84" AFF (VERIFY w/ OWNER) DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV 1/4" = 1'-0" FS1.40 Special Conditions Plan 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06 -11-21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM SEE NOTES PAGE FOR WALL BACKING DETAILS AND GENERAL NOTES 18" X 36" 18" X 20"18" X 20"18" X 20"24"24"36"W X 24"D18" X 36" 18" X 48" 18" X 36"36"W X 24"D36"W X 24"D18" X 48"72"W X 30"D18" X 36" 18" X 36"18" X 36"24" X 36"24" X 36" FS1.51 4 FS1.50 2 4 2 SECURE SHELVING DISH REFRIG1-DOOR REFRIG FREEEZER DRY STORAGE PREP SINK W/ POT RACK H.S. MOP / MOP BUCKET / CHEMICAL STORAGE UC DISH MACHINE TRASH POS 71 72 3 ADA TRANSACTION COUNTER/ ADA SEATING COUNTER 3 TRASH TURBO CHEF PANINI WALL CONVECTION W/ SHELF RACK 185"102"PREP COCKTAIL STATION GLASSES MUG FROSTER COCKTAIL STATION GLASSES REFRIG WINE ICE KOLD- DRAFT REFRIG GLASS- WASH WINE REFRIG234"99" 114"264"1231512 14 11 13 6 6 6 8 8 7 18 23 23 25 1922 21 20 24 30 29 28 36 35 33 41 42 43 44 42 41 43 45 51 52 53 54 55 52 51 67 66 65 64 63 62 61 34 50 FILTER BAKERY CASE 56 68 H.S.VERIFY50 34 2323 2323 18 1921 22 20 36"31"36"12"103 1/2" 24 25 34"10 1/4"66"18 49" 49"VERIFY34 50 30 3536 33 28 29 66"36" 72"23 1/4" 1231311 12 15 1515 48"36"48"66"12"54 1/2"27"54 1/2" DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV As indicated FS1.50 Equipment Elevations 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06 -11-21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM 1/2" = 1'-0"2 Elevation - BOH Dish and Prep 1/2" = 1'-0"4 Elevation - BOH Warming 1/2" = 1'-0"3 Elevation - BOH Mop / Refrigeration 5 Perspective - BOH6Perspective - BOH 2 18" X 36" 18" X 20"18" X 20"18" X 20"24"24"36"W X 24"D18" X 36" 18" X 48" 18" X 36"36"W X 24"D36"W X 24"D18" X 48"72"W X 30"D18" X 36" 18" X 36"18" X 36"24" X 36"24" X 36" FS1.51 4 FS1.50 2 4 2 SECURE SHELVING DISH REFRIG1-DOOR REFRIG FREEEZER DRY STORAGE PREP SINK W/ POT RACK H.S. MOP / MOP BUCKET / CHEMICAL STORAGE UC DISH MACHINE TRASH POS 71 72 3 ADA TRANSACTION COUNTER/ ADA SEATING COUNTER 3 TRASH TURBO CHEF PANINI WALL CONVECTION W/ SHELF RACK 185"102"PREP COCKTAIL STATION GLASSES MUG FROSTER COCKTAIL STATION GLASSES REFRIG WINE ICE KOLD- DRAFT REFRIG GLASS- WASH WINE REFRIG234"99" 114"264"1231512 14 11 13 6 6 6 8 8 7 18 23 23 25 1922 21 20 24 30 29 28 36 35 33 41 42 43 44 42 41 43 45 51 52 53 54 55 52 51 67 66 65 64 63 62 61 34 50 FILTER BAKERY CASE 56 68 H.S. 226" HORIZANTAL ELECTRICAL OUTLETS TO BE POSITIONED DIRECTLY UNDER COUNTER TOP SURFACE. ELECTRIC OUTLETS TO BE POSITIONED CLEAR ABOVE EQUIPMENT BACKSPLASH COUNTERTOP AND EQUIPMENT BACKSPLASH (TYP.) 45 43 41 42 44 43 42 41 24"18"60"18"18"60" 72 71 34"42"24" 68 30" 68 67 66 64 6563 6261 51 52 53 54 55 52 51 56 24"24"24"26"25 1/4"24"24"12" DRAWING SHEET NO. SCALE: JOB NAME: SHEET NAME: COPYRIGHT. THESE DOCUMENTS IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT, ARE THE SOLE PROPERTY OF SINGER EQUIPMENT COMPANY. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION OR ADOPTION WITHOUT THE EXPRESS WRITTEN CONSENT OF SINGER EQUIPMENT COMPANY IS STRICTLY PROHIBITED. Singer Equipment Company ADDRESS: SUBMITTALS & REVISIONS DATE DESCRIPTIONNAME DRAWN BY: CHECKED BY: PROJECT #: REV As indicated FS1.51 Equipment Elevation 180 Heller Place, Bellmawr, NJ 08030 856-559-4200 JCB JR 06 -11-21 JCB SCHEMATIC DESIGN DEVELOPMENT 06-30-21 JCB ROUGH-INS AND ELEVATIONS 07-28-21 JCB REDESIGN PLAN09-22-21 KM 1/2" = 1'-0"2 Elevation - Front Bar 1/2" = 1'-0"3 Elevation - Front Counter 1/2" = 1'-0"4 Elevation - Back Bar MILLWORK DRAWN FOR REFERENCE ONLY. REFER TO ARCHITECTRUAL AND OR MILLWORK SHOP DRAWINGS FOR DETAILS AND DIMENSIONS. 5 Perspective - Front Bar 6 Perspective - Bar