36 HERS Final Laverdiere 175 Jackson Unit 4Home Energy Rating Certificate Rating Date: 2022-08-22 HIS
Final Report Registry ID: 6882OSS30 HERS
Ekatrope ID: 6LA4p4A2
Your Home's Estimated Energy Use:
Use [Motu]
Annual Cost
Heating
3.7
$237
Cooling
0.2
$15
Hot Water
1.0
$65
Lights/Appliances
8.0
$518
Service Charges
$120
Generation (e.g. Solar)
0.0
$0
Total:
12.9
$955
HERS IndeK
Horne Feature Summary:
More Energy
Horne Type:
Apartment, end unit
ls0
Model:
NIA
Existing 140
Community:
NIA
Homes 130
Conditioned Floor Area:
536 ft2
170
Number of Bedrooms:
1
llo
Reference mn
Primary Heating System:
Air Source Heat Pump • Electric • 3.02 COP
Home
90
Primary Cooling System:
Air Source Heat Pump • Electric • 17 SEER
so
Primary Water Heating:
Residential Water Heater • Electric • 3.75 U E F
'°
House Tightness:
175.1 CFM50 (2.18 ACH50)
60
Ventilation:
33 CFM • 11 Watts
_Jfto
Duct Leakage to Outside:
Forced Air Ductless
30
Above Grade Walls:
R-21
20 This Home
Ceiling:
Attic, R-54
Zero Energy L0
Window Type:
U-Value:0.27, SHGC: 0.28
Home 0
Foundation WaI Is:
NIA
Less Entrrgy
w
ww]RFSICr
Framed Floor:
R-49
This home meets or exceeds the
criteria of the following:
2018 International Energy Conservation Code
Rating Completed by:
Energy Rater: Adin Maynard
RESNET ID. 9463452
Rating Company: HIS & HERS Energy Efficiency
57R Adams Rd. Williamsburg, MA 01039
4136588784
Rating Provider: Energy Raters of Massachusetts
2 Woodlawn Street Amesbury, MA 01913
978-270-3911
� - a
x !b. 1998 136 .�
Adin Maynard, Certified Energy Rater
Digitally signed: 8122/22 at 10:06 PM
IECC 2018 Label
175 Jackson St Unit 4
Ekotrope RATER - Version: 3.2.4.2973
HERSO Index Score: 36
Building Envelope Specs
Ceiling: R-54
Above Grade Walls: R-21
Foundation Walls: N/A
Exposed Floor: R-49
Slab: NIA
Infiltration: 175.1 CFM50 (2.18 ACH50)
Duct Insulation: NIA
Duct Lkg to Outdoors: Forced Air Ductless
Window & Door Specs
U-Value: 0.27, SHGC: 0.28
Door: R-6
Mechanical Equipment Specs
Heating: Air Source Heat Pump • Electric • 3.02
COP
Cooling: Air Source Heat Pump • Electric • 17
SEER
Hot Water: Residential Water Heater • Electric
3.75 U EF
Average Mechanical Ventilation: 33 CFM
Builder or Design Professional
Signature:
Air Leakage Report
Property
175 Jackson St Unit 4
Northampton, MA 01060
Laverdiere Garage residence unit 4
Laverdiere Unit 4 Final
Organization
HIS & HERS Energy Effici,
Adin Maynard
4136588784
Builder
Karan LaVerdiere
Inspection Status HIS
2022-08-22 HERS
Rater IQ (RTIN): 9463452
RESNET Registered
(Confirmed)
General Information
Conditioned Floor Area [ftj
535
Infiltration Volume [ft3]
4,824
Number of Bedrooms
1
Air Leakage
Measured Infiltration
175.1 CFM50 (2.18 ACH50)
ACH50 (Calculated)
2.18
ELA [sq. in.] (Calculated)
9.63
ELA per 100 s.f. Shell Area (Calculated)
0.505
CFM50 (Calculated)
175
CFM501 s.f. Shell Area (Calculated)
0.092
Duct Leakage
Leakage to Outdoors
Total Leakage Test Type
Total Leakage [CFM @ 25 Pa]
Total Leakage [CFM251 100 s.f.]
Total Leakage [CFM251 CFA]
Mechanical Ventilation
Rate [CFM]
33 CFM
Hours per day
24.0
Fan Power
11 Watts
Recovery Efficiency %
0.0
Runs at least once every 3 hrs?
true
Average Rate [CFM]
33.0 CFM
2010 ASH RAE 62.2 Req. Cont. Ventilation
20.4
2013 ASH RAE 62.2 Req. Cont. Ventilation
31.1
Ekotrope RATER - Version 3.2.4.2973
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
Building Specification Summary
Property
175 Jackson St Unit 4
Northampton, MA 01060
Laverdiere Garage residence unit 4
Laverdiere Unit 4 Final
Building Information
Conditioned Area [ftj
Conditioned Volume [W]
Thermal Boundary Area [ftj
Number Of Bedrooms
Housing Type
Organization Inspection Status
HIS & HERS Energy Effie!, 2022-08-22
Adin Maynard Rater la (RTIN): 9463452
4136588784 RESNET Registered
(Confirmed)
Builder
Karan Laverdiere
Rating
536.00 HERS Index
4,824.00
1,906.00
1
Apartment, end unit
Building Shell
Ceiling wl Attic
R53_mmnl ,CE15"A-24_bttmchrd; U-0.019
Vaulted Ceiling I None
Above Grade Walls I R21 FG, G1 6-16; U-0.057
Found. Walls I None
Framed Floors
16" ijoist FG batts R30 + R19_R47effcty; R49
Slabs I None
Mechanical Systems
Heating
Cooling
Water Heating
Programmable Thermostat
Ventilation System
Whole House Fan
Lights and Appliances
Percent Interior LED
Percent Exterior LED
Refrigerator (kWhlyr)
Dishwasher Efficiency
Ceiling Fan
HERS Index w/o PV
36
36
HIS
HERS
Windows (largest) I U-Value: 0.27, SHGC: 0.28
Window / Wall Ratio 10.08
Infiltration 1175.1 CFM50 (2.18 ACH50)
Duct Lkg to Outside I Forced Air Ductless
Total Duct Leakage Untested
Air Source Heat Pump • Electric • 3.02 COP
Air Source Heat Pump • Electric • 17 SEER
Residential Water Heater • Electric • 3.75 UEF
Yes
33 CFM • 11 Watts
NIA
100%
Clothes Dryer Fuel
100%
Clothes Dryer CEF
387.0
Clothes Washer LER (kWhlyr)
270 kWh
Clothes Washer Capacity
None
Range/Oven Fuel
Electric
3.9
100.0
4.5
Electric
Ekotrope RATER - Version 3.2.4.2973
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.
RESNET HOME ENERGY HIS
RATING Standard Disclosure HERS
For home(s) located at: 175 Jackson St Unit 4,
Northampton, AAA
Check the applicable disclosure(s):
[1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home.
E]2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services
for this home:
E[A. Mechanical system design
E[ B. Moisture control or indoor air quality consulting
E[C. Performance testing and/or commissioning other than required for the rating itself
E[ D. Training for sales or construction personnel
E[ E. Other(specify)
E]3. The Rater or the Rater's employer is:
E]A. The seller of this home or their agent
E[ B. The mortgagor for some portion of the financed payments on this home
E]C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home
Ej4. The Rater or Rater's employer is a supplier or installer of products, which may include:
Products
HVAC systems
Installed in this home by
LjRater []Employer
OR is in the business of
LIRater Employer
Thermal insulation systems
Rater
[]Employer
Rater
Employer
Air sealing of envelope or duct systems
Rater
[]Employer
Rater
Employer
Energy efficient appliances
Rater
[]Employer
Rater
Employer
Construction (builder, developer, construction contractor, etc)
11 Rater
[]Employer
Rater
Employer
Other (specify): C
EIRater
LjEmpoyer
Ll Rater
rEmpioyer
5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for
Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy
Services Network (RESNET). Rater Certification #: 9463452
Name: Adin Maynard Signature:
Organization: HIS & HERS Energy Efficiency Digitally signed: 8/22/22 at 10:06 PM
I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating
Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating
Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality
control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are
posted at
https:/Istandards.resnet.us
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
45L Tax Credit
Property
175 Jackson St Unit 4
Northampton, MA 01060
Laverdiere Garage residence unit 4
Laverdiere Unit 4 Final
Organization
HIS & HERS Energy Effie!,
Adin Maynard
4136588784
Builder
Karan LaVerdiere
Inspection Status
2022-08-22
Rater ID (RTIN): 9463452
RESNET Registered
(Confirmed)
RESNET Confirmed Rating
Normalized Modified End -Use Loads (MBtu 1
year)
Category 2006 IECC 50% As Designed
Target
Heating 5.4 5.2
Cooling 0.8 0.7
Total 6.2 5.9
Building Features
HIS
HERS
Envelope Loads (MBtu / year)
Category 2006 IECC As Designed
90% Target
Heating 9.8 5.3
Cooling 1.4 1.3
Total 11.2 6.6
Ceiling U: 0.019 Heating System: Air Source Heat Pump
Wall U: 0.057 Electric • 3.02 COP
Framed Floor U: 0.021 Cooling System: Air Source Heat Pump
Slab R: NIA Electric • 17 SEER
Glazing Properties: U-Value: 0.27, SHGC: 0.28 Duct Leakage to Outside: Forced Air Ductless
This home meets the requirements for the residential energy efficiency tax credit under section 1332, Credit for
Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005. Builder should verify that the 45L Tax
Credit is available for the year in which this home was built.
The undersigned certifier verifies that:
(1) The dwelling unit has a projected level of annual heating and cooling energy consumption that is at least 50 percent
below the annual level of heating and cooling energy consumption of a reference dwelling unit in the same climate zone;
(2) Building envelope component improvements alone account for a level of annual heating and cooling energy
consumption that is at least 10 percent below the annual level of heating and cooling energy consumption of a reference
dwelling unit in the same climate zone; and
(3) Heating and cooling energy consumption have been calculated in the manner prescribed in section 2.03 of this notice.
(4) Field inspections of the dwelling unit (or of other dwelling units under the ENERGY STAR® for Homes Sampling
Protocol Guidelines) performed by the eligible certifier during and after the completion of construction have confirmed that
all features of the home affecting such heating and cooling energy consumption comply with the design specifications
provided to the eligible certifier.
"Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the
best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete."
Name: Adin Maynard
Signature:
Organization: HIS & HERS Energy Efficiency Digitally signed: 8/22/22 at 10:06 PM
Ekotrope RATER - Version 3.2.4.2973
All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.