Loading...
38 HERS Final Laverdiere 175 Jackson St Unit 3Home Energy Rating Certificate Rating Date, 2022-08-22 HIS Final Report Registry ID, 819335246 HERS Ekatrope ID: DLzakZo2 Your Home's Estimated Energy Use: Use [Motu] Annual Cost Heating 3.7 $242 Cooling 0.3 $17 Hot Water 1.0 $65 Lights/Appliances 8.5 $551 Service Charges $120 Generation (e.g. Solar) 0.0 $0 Total: 13.6 $994 HERS IndeK Home Feature Summary: Mon E-W Horne Type: Apartment, end unit Lso Model: NIA Existing 140 Community: NIA Homes 130 Conditioned Floor Area: 536 ft2 170 Number of Bedrooms: 1 ilo Reference mn Primary Heating System: Air Source Heat Pump • Electric • 3.02 COP Home 90 Primary Cooling System: Air Source Heat Pump • Electric • 17 SEER so Primary Water Heating: Residential Water Heater • Electric • 3.75 U E F '° House Tightness: 234 CFM50 t291 ACH50j 6o Ventilation: 35 CFM • 11 Watts o� Duct Leakage to Outside: Forced Air Ductless w Above Grade Walls: R-21 This Home 20 Ceiling: Attic, R-54 Zero Energy 1° Window Type: U-Value:0.29, SHGC:0.32 Home 0 Foundation WaI Is: NIA � Less EftegV R7RW]RFSKr Framed Floor: R-49 This home meets or exceeds the criteria of the following: 2018 International Energy Conservation Code Rating Completed by: Energy Rater: Adin Maynard RESNET ID. 9463452 Rating Company: HIS & HERS Energy Efficiency 57R Adams Rd. Williamsburg, MA 01039 4136588784 Rating Provider: Energy Raters of Massachusetts 2 Woodlawn Street Amesbury, MA 01913 978-270-3911 � - a x !b. 1998 136 .� Adin Maynard, Certified Energy Rater Digitally signed: 8122/22 at 10:08 PM IECC 2018 Label 175 Jackson St Unit 3 Ekotrope RATER - Version: 3.2.4.2973 HERSO Index Score: 38 Building Envelope Specs Ceiling: R-54 Above Grade Walls: R-21 Foundation Walls: N/A Exposed Floor: R-49 Slab: NIA Infiltration: 234 CFM50 (2.91 ACH50) Duct Insulation: NIA Duct Lkg to Outdoors: Forced Air Ductless Window & Door Specs U-Value: 0.29, SHGC: 0.32 Door: R-6 Mechanical Equipment Specs Heating: Air Source Heat Pump • Electric • 3.02 COP Cooling: Air Source Heat Pump • Electric • 17 SEER Hot Water: Residential Water Heater • Electric 3.75 U EF Average Mechanical Ventilation: 35 CFM Builder or Design Professional Signature: Air Leakage Report Property 175 Jackson St Unit 3 Northampton, MA 01060 Laverdiere Garage residence unit 3 Laverdiere Unit 3 Final Organization HIS & HERS Energy Effici, Adin Maynard 4136588784 Builder Karen LaVerdiere Inspection Status HIS 2022-08-22 HERS Rater IQ (RTIN): 9463452 RESNET Registered (Confirmed) General Information Conditioned Floor Area [ftj 535 Infiltration Volume [ft3] 4,824 Number of Bedrooms 1 Air Leakage Measured Infiltration 234 CFM50 (2.91 ACH50) ACH50 (Calculated) 2.91 ELA [sq. in.] (Calculated) 12.87 ELA per 100 s.f. Shell Area (Calculated) 0.675 CFM50 (Calculated) 234 CFM501 s.f. Shell Area (Calculated) 0.123 Duct Leakage Leakage to Outdoors Total Leakage Test Type Total Leakage [CFM @ 25 Pa] Total Leakage [CFM251 100 s.f.] Total Leakage [CFM251 CFA] Mechanical Ventilation Rate [CFM] 35 CFM Hours per day 24.0 Fan Power 11 Watts Recovery Efficiency % 0.0 Runs at least once every 3 hrs? true Average Rate [CFM] 35.0 CFM 2010 ASH RAE 62.2 Req. Cont. Ventilation 20.4 2013 ASH RAE 62.2 Req. Cont. Ventilation 31.1 Ekotrope RATER - Version 3.2.4.2973 All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Building Specification Summary Property 175 Jackson St Unit 3 Northampton, MA 01060 Laverdiere Garage residence unit 3 Laverdiere Unit 3 Final Building Information Conditioned Area [ftj Conditioned Volume [W] Thermal Boundary Area [ftj Number Of Bedrooms Housing Type Organization Inspection Status HIS & HERS Energy Effie!, 2022-08-22 Adin Maynard Rater la (RTIN): 9463452 4136588784 RESNET Registered (Confirmed) Builder Karen Laverdiere Rating 536.00 HERS Index 4,824.00 1,906.00 1 Apartment, end unit Building Shell Ceiling wl Attic R53_mmnl ,CE15"A-24_bttmchrd; U-0.019 Vaulted Ceiling I None Above Grade Walls I R21 FG, G1 6-16; U-0.057 Found. Walls I None Framed Floors 16" ijoist FG batts R30 + R19_R47effcty; R49 Slabs I None Mechanical Systems Heating Cooling Water Heating Programmable Thermostat Ventilation System Whole House Fan Lights and Appliances Percent Interior LED Percent Exterior LED Refrigerator (kWhlyr) Dishwasher Efficiency Ceiling Fan HERS Index w/o PV 38 38 HIS HERS Windows (largest) I U-Value: 0.29, SHGC: 0.32 Window / Wall Ratio 10.10 Infiltration 1234 CFM50 (2.91 ACH50) Duct Lkg to Outside I Forced Air Ductless Total Duct Leakage Untested Air Source Heat Pump • Electric • 3.02 COP Air Source Heat Pump • Electric • 17 SEER Residential Water Heater • Electric • 3.75 UEF Yes 35 CFM • 11 Watts NIA 100% Clothes Dryer Fuel 100% Clothes Dryer CEF 387.0 Clothes Washer LER (kWhlyr) 270 kWh Clothes Washer Capacity None Range/Oven Fuel Electric 2.7 80.0 2.4 Electric Ekotrope RATER - Version 3.2.4.2973 All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. RESNET HOME ENERGY HIS RATING Standard Disclosure HERS For home(s) located at: 175 Jackson St Unit 3, Northampton, AAA Check the applicable disclosure(s): [1. The Rater or the Rater's employer is receiving a fee for providing the rating on this home. E]2. In addition to the rating, the Rater or the Rater's employer has also provided the following consulting services for this home: E[A. Mechanical system design E[ B. Moisture control or indoor air quality consulting E[C. Performance testing and/or commissioning other than required for the rating itself E[ D. Training for sales or construction personnel E[ E. Other(specify) E]3. The Rater or the Rater's employer is: E]A. The seller of this home or their agent E[ B. The mortgagor for some portion of the financed payments on this home E]C. An employee, contractor, or consultant of the electric and/or natural gas utility serving this home Ej4. The Rater or Rater's employer is a supplier or installer of products, which may include: Products HVAC systems Installed in this home by LjRater []Employer OR is in the business of LIRater Employer Thermal insulation systems Rater []Employer Rater Employer Air sealing of envelope or duct systems Rater []Employer Rater Employer Energy efficient appliances Rater []Employer Rater Employer Construction (builder, developer, construction contractor, etc) 11 Rater []Employer Rater Employer Other (specify): C EIRater LjEmpoyer Ll Rater rEmpioyer 5. This home has been verified under the provisions of Chapter 6, Section 603 "Technical Requirements for Sampling" of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET). Rater Certification #: 9463452 Name: Adin Maynard Signature: Organization: HIS & HERS Energy Efficiency Digitally signed: 8/22/22 at 10:08 PM I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry NationalHome Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 102.1.4.6 of the standard and are posted at https:/Istandards.resnet.us The Home Energy Rating Standard Disclosure for this home is available from the rating provider. 45L Tax Credit Property 175 Jackson St Unit 3 Northampton, MA 01060 Laverdiere Garage residence unit 3 Laverdiere Unit 3 Final Organization HIS & HERS Energy Effie!, Adin Maynard 4136588784 Builder Karen LaVerdiere Inspection Status 2022-08-22 Rater ID (RTIN): 9463452 RESNET Registered (Confirmed) RESNET Confirmed Rating Normalized Modified End -Use Loads (MBtu 1 year) Category 2006 IECC 50% As Designed Target Heating 5.6 5.3 Cooling 0.8 0.8 Total 6.4 6.1 Building Features HIS HERS Envelope Loads (MBtu / year) Category 2006 IECC As Designed 90% Target Heating 10.1 5.6 Cooling 1.5 1.5 Total 11.6 7.1 Ceiling U: 0.019 Heating System: Air Source Heat Pump Wall U: 0.057 Electric • 3.02 COP Framed Floor U: 0.021 Cooling System: Air Source Heat Pump Slab R: NIA Electric • 17 SEER Glazing Properties: U-Value: 0.29, SHGC: 0.32 Duct Leakage to Outside: Forced Air Ductless This home meets the requirements for the residential energy efficiency tax credit under section 1332, Credit for Construction of New Energy Efficient Homes, of the Energy Policy Act of 2005. Builder should verify that the 45L Tax Credit is available for the year in which this home was built. The undersigned certifier verifies that: (1) The dwelling unit has a projected level of annual heating and cooling energy consumption that is at least 50 percent below the annual level of heating and cooling energy consumption of a reference dwelling unit in the same climate zone; (2) Building envelope component improvements alone account for a level of annual heating and cooling energy consumption that is at least 10 percent below the annual level of heating and cooling energy consumption of a reference dwelling unit in the same climate zone; and (3) Heating and cooling energy consumption have been calculated in the manner prescribed in section 2.03 of this notice. (4) Field inspections of the dwelling unit (or of other dwelling units under the ENERGY STAR® for Homes Sampling Protocol Guidelines) performed by the eligible certifier during and after the completion of construction have confirmed that all features of the home affecting such heating and cooling energy consumption comply with the design specifications provided to the eligible certifier. "Under penalties of perjury, I declare that I have examined this certification, including accompanying documents, and to the best of my knowledge and belief, the facts presented in support of this certification are true, correct, and complete." Name: Adin Maynard Signature: Organization: HIS & HERS Energy Efficiency Digitally signed: 8/22/22 at 10:08 PM Ekotrope RATER - Version 3.2.4.2973 All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.