Klepacki - BP BinderAERIAL MAP NOT TO SCALEA SITE PLAN NOT TO SCALEB PROJECT INFORMATION: Project:KLEPACKI FLORENCE Address:107 BAKER HILL RD NORTHAMPTON, MA 01062 SYSTEM DETAILS Total System Size: 9.0 kW DC (Solar) 7.6 kW AC (Solar) Modules:(25) REC360NP2 Black Inverters:(1) SolarEdge 7.6kw HD-Wave w/ RGM Optimizers (25) SolarEdge S440 DESIGN CRITERIA Design Snow Load 35 (psf) Design Wind Speed 117 (mph) Exposure Category B Risk Category II AUTHORITY HAVING JURISDICTION Building:Kevin Ross (413) 587-1239 Electrical:Roger Malo (413) 587-1244 Electrical Utility:NATIONAL GRID Code Ref NEC 2020 (MA) PROJECT NOTES Roof Insulation thickness unknown. SOLAR ARRAY (ROOF) MAIN LOAD CENTER MAIN SERVICE DISCONNECT SOLAR PV EQUIPMENT (BASEMENT) UTILITY SERVICE METER SOLAR PV DISCONNECT (OUTSIDE) 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: KLEPACKI FLORENCE 107 BAKER HILL RD NORTHAMPTON, MA 01062 SITE PLAN & PROJECT INFO. 8/8/2022 RTC NO SCALE 11x17 PV-M1 0 Roof 36913 16" Array 206 3 16" Array 1647 8"Roof 378"Roof 284" R o o f 2 5 8 " A r r a y 1 6 4 7 8"24"24"Array 25514"Array 25514"( 1 4 ' ) 1 6 6 7 8"(14') 1667 8" (14') 168"(14') 40 3 16" 83 4" 37 8" 1 3 16"4015 16" 69 1 16" 93 4"2438"MODULE DETAIL SCALE: 1/4" = 1'-0"A ARRAY LAYOUT SCALE: 3/16" = 1'-0"B Rafters 24" OC Rail GARAGE ROOF Unirac Flashloc RM Bases Install on Decking at 38.5" OC to Match Rafters 6 Screws per Base LOCATE APPROX. OVER RAFTERS ROOF SPECIFICATIONS: Material: Membrane Attachment Structure Decking/Rafters Pitch 15° Azimuth 180° / 225° MODULE SPECIFICATIONS: MODULE MODEL: REC360NP2 Black Dimensions:69.09" x 40.94" x 30mm Clamp Long Side:8 3/4"-24 3/8" Clamp Short Side:3 7/8"-9 3/4" RAIL SPECIFICATIONS Make & Model:Ironridge XR100 Clamp Torque:80 in-lbs L-Foot Torque:250 in-lbs Max Cantilever:22" ATTACHMENT SPECIFICATIONS Bases/Flashing:Unirac Flashloc RM with Iron Ridge Tilt Legs Fasteners:OMG Retrodriller RDDP007B 7" or Similar Confirm Length Onsite 6 Screws per Base Sealant:Chemlink M-1 Max. Spacing:48" ARRAY NOTES 1.Framing and attachment locations to be verified on site. 2.Bases are staggered to distribute point loading except at edges of array. 3.Additional or alternative bases may be used to meet actual roof conditions. 4.Ironridge Rail Gap Spacing: 4.1.3/8" Horizontal Spacing 4.2.1/4" Vertical Spacing 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: KLEPACKI FLORENCE 107 BAKER HILL RD NORTHAMPTON, MA 01062 ARRAY LAYOUT & ROOF DATA 8/8/2022 RTC AS SHOWN 11x17 PV-M2 0 Rafters (I-Joist) 19.25" OC EXPOSED INSIDE GARAGE HOUSE ROOF Unirac Flashloc RM Bases Install on Decking Max. 48" OC 6 Screws per Base 22516"187 8 " 187 8 " 4 7 16"15°3513 16" 24" 5415 16" 67 1 16"67 1 16" IRON RIDGE TILT UP ASSEMBLY DETAIL SCALE: 1:16A 311 WELLS STREET, SUITE B GREENFIELD, MA 01301 WWW.PVSQUARED.COOP 413-772-8788 SIZE: PV SQUARED SOLAR SCALE: DATE: BY: REV: KLEPACKI FLORENCE 107 BAKER HILL RD NORTHAMPTON, MA 01062 ARRAY DETAIL 8/8/2022 RTC AS SHOWN 11x17 PV-M3 0 IRON RIDGE NORTH TILT LEG IRON RIDGE SOUTH TILT LEG XR100 RAIL IRON RIDGE U-FOOT UNIRAC FLASHLOC RM New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction, VT 05001 Jonathan Rugg, P.E. 603-903-9798 j.rugg@NewEnglandConstructionEngineering.com   June 1, 2022      Ms. Madeleine Geschwind  Pioneer Valley PhotoVoltaics Cooperative, Inc.  311 Wells Street, Suite B  Greenfield, MA 01301    Re: Klepacki residence, florence, MA   NECE Project No. 22‐01 T‐34      Dear Ms. Geschwind,    At your request New England Construction Engineering, PLC (NECE) has reviewed the  information that Pioneer Valley PhotoVoltaics Cooperative, Inc. (PV Squared) provided on the  Klepacki residence at 107 Baker Hill Road, in Florence (village of Northampton), MA. The  purpose of this review was to provide an opinion regarding the structure's capacity to support a  proposed rooftop mounted photovoltaic (PV) array. The information that you provided is  attached to this letter for reference.     You are proposing to mount rooftop PV panels on the house roof and attached garage. The  house is a contemporary design. Both the house and attached garage have flat roofs. Town tax  records indicate that the house was constructed circa 1996. You have provided design plans for  the building. The design plans indicate that the main house roof was framed with 2x12 roof  joints at 24”O.C. These joists typically span approximately 14’ to 14’‐6” between supports.     The garage roof is framed with 14” TJI, wood I‐joists at 19.2” O.C. The garage is unfinished, and  based on the I‐joints flange dimensions, the TJIs are 230 Series, 14” TJIs. These joists span  between 21’ ‐6” and 23’‐9”.     NECE’s review and analysis included controlling gravity load combinations (snow and dead load).     Conclusion:  Based on my review of the information that you provided, I have concluded that, the roof will  support your proposed PV Array. I base this opinion on the following. The ground snow load (Pg)  for Northampton is 40psf. The minimum flat roof snow load (Pf) is also 35psf. The information  that you provided indicates that the proposed panels and racking weigh approximately 2.8psf.       New England Construction Engineering, PLC PV Squared – Klepacki Residence Jonathan Rugg, P.E. Florence, MA Page 2 of 2 In summary, in my opinion, the house and attached garage roof will support your proposed PV  array.     Thank you for the opportunity to assist with this project. If I can be of further assistance, please  contact Jonathan Rugg at NECE.       Sincerely,           Jonathan Rugg, P.E.    New England Construction Engineering, PLC.      Attachments:    ‐Building & Proposed Array Information    wp Power ELIGIBLE PREMIUM FULL BLACK MONO N-TYPE SOLAR PANELS rec N-Peak 2 Black Series MONO N-TYPE: THE MOST EFFICIENT C-SI TECHNOLOGY SUPER-STRONG FRAME UP TO 7000 PA SNOW LOAD FEATURING REC’S PIONEERING TWIN DESIGN FLEXIBLE INSTALLATION OPTIONS NO LIGHT INDUCED DEGRADATION 370 BIFACIAL CELLS CAN PRODUCE ENERGY FROM BOTH SIDES Ref: PM-DS-11-04-Rev- D 03.22www.recgroup.com Specifications subject to change without notice.Measurements in mm [in] LOW LIGHT BEHAVIOUR Typical low irradiance performance of module at STC: Irradiance (W/m²)Rel. Efficiency (%)Founded in 1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable solar power. As Solar’s Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Europe, and Asia-Pacific. 85 90 95 100 105 200100 300 400 500 600 700 800 900 1000 REC N-Peak 2 Black Series Product SPECIFICATIONS GENERAL DATA Cell type:120 half-cut bifacial mono c-Si n-type cells 6 strings of 20 cells in series Glass:0.13 in (3.2 mm) solar glass with anti-reflective surface treatment in accordance with EN 12150 Backsheet:Highly resistant polymer (black) Frame:Anodized aluminum (black) with silver support bars Junction box:3-part, 3 bypass diodes, lead-free IP68 rated, in accordance with IEC 62790 Connectors:Stäubli MC4 PV-KBT4/KST4 (4 mm²) in accordance with IEC 62852, IP68 only when connected Cable:12 AWG (4 mm²) PV wire, 43+ 47 in (1.1 + 1.2 m) in accordance with EN 50618 Dimensions:69.1 x 40.94 x 1.2 in (19.70 ft2) / 1755 x 1040 x 30 mm (1.83 m2) Weight:44.0 lbs (20.0 kg) Origin:Made in Singapore WARRANTY Standard REC ProTrust Installed by an REC Certified Solar Professional No Yes Yes System Size All ≤25 kW 25-500 kW Product Warranty (yrs)20 25 25 Power Warranty (yrs)25 25 25 Labor Warranty (yrs)0 25 10 Power in Year 1 98%98%98% Annual Degradation 0.25%0.25%0.25% Power in Year 25 92%92%92% See warranty documents for details. Conditions apply TEMPERATURE RATINGS * Nominal Module Operating Temperature:44.3°C (±2 °C) Temperature coefficient of PMAX:-0.34 %/°C Temperature coefficient of VOC:-0.26 %/°C Temperature coefficient of ISC:0.04 %/°C *The temperature coefficients stated are linear values CERTIFICATIONS IEC 61215:2016, IEC 61730:2016, UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance UL 61730 Fire Type Class 2 IEC 62782 Dynamic Mechanical Load IEC 61215-2:2016 Hailstone (35mm) ISO 14001, ISO 9001, IEC 45001, IEC 62941 DELIVERY INFORMATION Panels per pallet:33 Panels per 40 ft GP/high cube container:858 (26 pallets) Panels per 53 ft truck:924 (28 pallets) MAXIMUM RATINGS Operational temperature:-40 ... +85°C Maximum system voltage:1000 V Maximum test load (front): + 7000 Pa (146 lbs/ft2)* Maximum test load (rear):- 4000 Pa (83.5 lbs/ft2)* Max series fuse rating:25 A Max reverse current:25 A * See installation manual for mounting instructions. Design load = Test load / 1.5 (safety factor) STC NMOTELECTRICAL DATA Product Code*: RECxxxNP2 Black Power Output - PMAX (Wp) 350 355 360 365 370 Watt Class Sorting - (W)0/+5 0/+5 0/+5 0/+5 0/+5 Nominal Power Voltage - VMPP (V) 33.1 33.5 33.9 34.3 34.7 Nominal Power Current - IMPP (A) 10.57 10.60 10.62 10.65 10.68 Open Circuit Voltage - VOC (V) 40.6 40.7 40.8 40.9 41.1 Short Circuit Current - ISC (A) 11.25 11.27 11.31 11.36 11.41 Panel Efficiency (%) 19.1 19.4 19.7 20.0 20.3 Power Output - PMAX (Wp)264 268 272 276 280 Nominal Power Voltage - VMPP (V) 31.0 31.3 31.7 32.1 32.5 Nominal Power Current - IMPP (A) 8.54 8.56 8.58 8.60 8.63 Open Circuit Voltage - VOC (V) 38.0 38.1 38.2 38.2 38.4 Short Circuit Current - ISC (A) 9.06 9.10 9.13 9.18 9.22 Values at standard test conditions (STC: air mass AM 1.5, irradiance 10.75 W/sq ft (1000 W/m²), temperature 77°F (25°C), based on a production spread with a tolerance of PMAX, VOC & ISC ±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 800 W/m², temperature 68°F (20°C), windspeed 3.3 ft/s (1 m/s). * Where xxx indicates the nominal power class (PMAX) at STC above. GR GRGR GR11±0.2 [0.43 ±0.1]6.6±0.2 [0.26 ±0.1]20.5±0.5 [0.8 ±0.02] GR 638 ±1 [25.1 ±0.04] 30 [1.2] 22.5 [0.9] 28 [1.1] 1755±2.5 [69.10 ±0.1] 845 [33.27] 156 [6.14] 156 [6.14] 455 [17.91]999 [39.33]1100 [43.3] 5.5±0.2 [0.22±0.01] 1200 [47.2]1040±2.5 [40.94 ±0.1]17 [0.7]45 [1.8] Cut Sheet See Description / Length 2.44 .58 1.25 2.34 1.99 .66 .46 APPROVED MATERIALS: 6005-T6, 6005A-T61, 6105-T5, 6N01-T6 (34,000 PSI YIELD STRENGTH MINIMUM) XR100 Rail v1.1 Cut Sheet v1.0 12.0 1 2 XR-100-SPLC-BD KIT, XR100 BONDED SPLICE 2) Screw, Self Drilling 1.93 1.24 .93 1) Splice, XR100, Mill 12" long .31 .42 .63 .15 #12-14 TYPE “B” THREAD XR-100 RAIL Property Value Material 6000 Series Aluminum Finish Mill Property Value Material 300 Series Stainless Steel Finish Clear XR100 Bonded Splice Cut Sheet Tilt Leg v1.1 5 8 3 6 2 4 1 7 TILT MOUNT KIT OPTIONS ITEM NO DESCRIPTION QTY IN KIT 1 BOLT, BONDING 3/8-16 SQ HEAD, 2.25"1 2 NORTH TILT LEG, 1.5" SQ, LENGTH VARIES 1 3 NUT, FLANGE HEX 3/8-16 SS 3 4 BOLT, BONDING 3/8-16 SQ HEAD, 1.0"1 5 PRE-ASSEMBLED SOUTH TILT LEG 1 6 WASHER, FLAT 3/8 SS 1 7 BOLT, 3/8-16 X 2.5" CS SST 1 8 U-FOOT 1 PART NUMBER DESCRIPTION NORTH TILT LEG LENGTH TM-FTL-010 Kit, Fixed Tilt Leg, 10", Mill 10" TM-FTL-015 Kit, Fixed Tilt Leg, 15", Mill 15" TM-FTL-020 Kit, Fixed Tilt Leg, 20", Mill 20" TM-FTL-025 Kit, Fixed Tilt Leg, 25", Mill 25" TM-FTL-030 Kit, Fixed Tilt Leg, 30", Mill 30" Cut Sheet 1.9 .31 .16 2.0 2.24 .38 .40 .75 7.0 2.1 2.0 1.0 .70 .75 .56 3/8-16 THD .35 .81 .41 .07 .56 .23 2.5 3/8-16 THD .56 .24 1.0 3/8-16 THD .24 2.25 3/8-16 THD .56 .61 Varies 1.48 1.48 8) U-Foot 2)North Tilt Leg 5)Pre-assembled South Tilt Leg 3) Nut, Flange Hex 3/8-16 SS 6) Washer, Flat 3/8 SS 7) Bolt, 3/8-16 X 2.5" CS SS 1,4) Bolt, Bonding 3/8-16 Sq Head 1.0" 2.25" Property Value Material AluminumFinishMill Property Value Material AluminumFinishMill Property Value Material AluminumFinishMill Property Value Material Stainless SteelFinishClear Property Value Material Stainless SteelFinishClear Property Value Material Stainless SteelFinishClear Property Value Material Stainless SteelFinishClear v1.1