Loading...
24A-026 (6) BP-2022-0888 95 RIDGEWOOD TERR COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24A-026-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-0888 PERMISSIONIS HEREBY GRANTED TO: Project# 2022 SOLAR Contractor: License: PIONEER VALLEY Est. Cost: 16151 PHOTOVOLTAICS 111266 Const.Class: Exp.Date:03/14/2023 Use Group: Owner: MICHEL DEE A TRUSTEE Lot Size (sq.ft.) Zoning: URB Applicant: PIONEER VALLEY PHOTOVOLTAICS Applicant Address Phone: Insurance: 311 WELLS ST - SUITE B (413)772-8788 375928710105 GREENFIELD, MA 01301 ISSUED ON:07/27/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 24 PANEL 3.24 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I• • yQ 51)17 Fees Paid: $75.00 212 Main Street, Phone(413) 587-1240,Fax:(413)587-1272 Office of the Building Commissioner L.:6> The Commonwealth of Massxlchus s �� �,✓ FOR Board of Building Regulations and 3t rds <S Massachusetts State Building Code,7$U;, c10( UN FUSE IPALITY Building Permit Application To Construct, Repair,Renoy � coolish a Revised Mar 2011 One-or Two-Family Dwelling Avs, This Section For Official Use Only goio60o'ys Building Permit Number: 7 9 Date Applied: I ifJ.Cal9r7 a7 as Building Official(Print Name) 1 Signature Ddte SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 95 Ridgewood Terrace,Northampton MA 01060 ') T 4(d 1,1 a Is this an accepted street?yes no Map NumbertT Parcel Num er 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: MICHEL,DEE Northampton,MA 01060 Name(Print) City,State,ZIP 95 Ridgewood Terrace (413)303-0489 deeamichel@comcast.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other 0 Specify:solar PV Brief Description of Proposed Work2:Installation of a 9 panel roof mounted solar array.System size 3.24kW DC. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $6515 1. Building Permit Fee: $ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical $9636 3 ❑Total Project Cost (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: $ Check No.1�))&fCheck Amount: J Cash Amount: 6. Total Project Cost: $ 16151 ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-111266 03/14/2023 Daniel Gomez-Gonzalez License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 43 Hatfield Street No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu. ft.) Northampton MA 01060 R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-772-8788 BUILDINGPERMITS@PVSOUARED.000P I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 140077 9/15/2023 PIONEER VALLEY PHOTOVOLTAICS COOP HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 311 WELLS STREET BUILDINGPERMITS@PVSOUARED COOP No.and Street Email address GREENFIELD MA 01301 413-772-8788 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes p No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Pioneer Valley Photovoltaics Coopertive to act on my behalf,in all matters relative to work authorized by this building permit application. SEE ATTACHMENT (A) SEEATTACHMENT(A) Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below, I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. r. 7/21/2022 Print Owner's or Authoriz Agent Name(lctronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" Attachment A • i sfp u)f.eci t +can Y7ntlr: rrr t 6 •; 1 yr 't. ;� t, :^Jn, • rt y,�t{.h...t • • C'.. :4.....4:11 • • • AUTHORIZATION.TO:PROCEED AND SERVE AS AUTHORIZED AGENT: • . . l !ief"t?lly,) reA 1-c: tft.�-Protect.,1 Set.:Out. aI ^'ve; a? ci l-*agree to:p j tmme-coin icl p ;2 uE•cGirdii VD. the T.rms of Payrrient. t•further agree to the Terms :..ind. Conditions' at-Oche-CI heretoa 1 part of tft_; Propu� d al ai ..Agreement I ►,er-eby author,ze Pioneer°tVa!!ev Phol:mV:omic; Coorera.tive rn proceed c�,tth.t`te t ove-i fHrenced . Fr'oject !rl•a Cor'c!3nce with this:,A,;reer nt. I:furLfier.autho irt� Pror-Fei �Jallej Pl?bto`vnft3,,cs Cdoperativ or its designated representative., to ob -ta required I;errnrt for.this oroiect On: V helm of he rt vr; r, t. vii'.all w anJ rlorcti'rajihs Or .vrcle05 Of this project•io be urea.b'.Pioneer,V ittey.PhOCUVonar is Cooperative for.•nia ketifie, ptir,-roses. Ache:k-for 117e F-r..st Pavrrenl r, eri,ao_ed.,ind i•.pn et'..iinior: t!'u u,',1et(Tlelli•1,:.1.i •1 iii. 2:1 mart, of the. Proposal..date... - • . .• . Dee MI:G _ -gr .'. 14 '..2.2 •Print ed•Name. .. • - •• • Date • • • • • Conitnonwealth of Massachusetts Division of Professional Licensure } Board of Building Regulations and Standards Constr-ttcti+ lV p rvisor CS-111266 Icpires: 03114/2023 DANIEL GOMEZ-GONZALEZ 43 HATFIELD STREET NORTHAMPTON MA 0106o 4-1r Commissioner -lad! . & Woeymnoiempeal/ie/A'a0JezeifeeJe/4- Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card PIONEER VALLEY PHOTOVOLTAICS COOPERATIVE. INC, Registration 140077 D/BIA PV SQUARED SOLAR E xprat+on' 09/1572023 311 WELLS ST SUITE B GREENFIELD,MA 01301 • a� f�� . le Address and Return Card. "On.Ve.N Conrar 4114 A tlti ryt Ili evinws kwavti n HOME IMPROVEMENT CONTRACTOR Registration valid for ind.vidual use only TYPE:S u0Divmvnt Ci'd before the expiration date. If found return to: ftegiilraLipn Expiration Office of Consumer Affairs sines'Regulation 140017 09.1023 1000 Washington Skeet uite 71 PIONF f K VA1 l EY NHOTOVOI TALCS COOPERATIVE.INC. Boston,MA 02118 DIM PV SQUARED SOLAR / MAYA FULFORD / 311 WELLS S1 .SUITE 0 f�.�./.t :6G..� 4 GREENFIELD,MA 01301 Undersecretary vOL valid without signature DATE(MM/DD/YYYY) A`O,R�® CERTIFICATE OF LIABILITY INSURANCE 12/30/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Kathy Parker NAME: Webber&Grinnell PHONE (413)586-0111 FAX (413)586-6481 (A/C,No,Ext): (A/C,No): 8 North King Street E-MAIL kparker@webberandgrinnell.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURER A: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltaics Cooperative, Inc. INSURER C: Continental Indemnity/AUW 28258 Attn:Kim Pinkham INSURER D: 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: CL21123017215 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS- INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) $ X XCU Included MED EXP(Any one person) $ 15,000 A BKS57072282 01/01/2022 01/01/2023 PERSONAL BAovINJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER. GENERAL AGGREGATE $ 2,000,000 POLICY X PRO LOC PRODUCTS-COMP/OP AGG $ 2,000,000 JECT OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ B OWNED X SCHEDULED BAS57072282 01/01/2022 01/01/2023 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X /HIRED . NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY " AUTOS ONLY (Per accident) X $1k Coll Ded X $1k Comp de Underinsured motorist $ 300,000 UMBRELLA LIAB CURRENCE"CE 5,000,000 X OCCUR EACH OCCURRE $ A EXCESS LIAB CLAIMS-MADE US057072282 01/01/2022 01/01/2023 AGGREGATE $ 5,000,000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION X STATUTE EORH AND EMPLOYERS'LIABILITY Y N C ANY PROPRIETOR/PARTNER/EXECUTIVE N NIA 375928710105 01/01/2022 01/01/2023 EL.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Business Personal Prop $1,820,700 Commercial Property A BKS57072282 01/01/2022 01/01/2023 Installation $25,000 Transportation $75,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) Worker's compensation includes MA and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Evidence of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts 1 iii1, Department of Industrial Accidents 11, 1 Congress Street, Suite 100 Boston, MA 02114-2017 . www.mass.gov/dia MP Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address:311 Wells Street, SuiteB City/State/Zip: Greenfield MA 01301 Phone #:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): l.�✓ I am a employer with 48 employees(full and/or part-time).* 7. ❑ New construction 2.1=l I am a sole proprietor or partnership and have no employees working for me in 8. ❑ Remodeling any capacity.[No workers'comp.insurance required.] 3.0 I am a homeowner doing all work myself.[No workers'comp.insurance required.] 9. ❑Demolition 10 ❑ Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.1=1 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. ]j ❑Roof repaiIS These sub-contractors have employees and have workers'comp.insurance.' 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14.❑✓ Other Solar PV 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. I.Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. *Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ant an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Continental Indemnity/AUW Policy#or Self-ins. Lic.#:37-592871-01-06 Expiration Date:01/01/2023 Job Site Address:95 Ridgewood Terrace City/State/Zip: Northampton, MA 01060 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152, §25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cer( r t e ai is and penalties of perjury that the information provided above is true and correct. Signatu Date: 7/21/2022 Phone#:413-7 2-87,$8 1 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2.Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: - PROJECT INFORMATION: SQ U44 Project: MICHEL4NORTHAMPTON a / .1 O Address: 95 Ridgewood Terrace // ``` NORTHAMPTON,MA 01060 SYSTEM DETAILS Total System Size: 3.24 kW DC(Solar) 14* • s°� 3.0 kW AC(Solar) PV SQUARED SOLAR Modules: (9)REC360AA Black 311 WELLS STREET,SUITE B Inverters: (1)SolarEdge 3kw HD-Wave w/RGM GREENFIELD.MA 01301 Optimizers (9)SolarEdge P505 WPAN.PVSOUARED.COOP 413.772-87138 DESIGN CRITERIA Design Snow Load 35(psf) MICHEL Design Wind Speed 117(mph) NORTHAMPTON Exposure Category B Risk Category II 95 RIDGEWOOD TERRACE NORTHAMPTON.MA 01060 AUTHORITY HAVING JURISDICTION Building: Kevin Ross (413)587-1239 ° ° Electrical: Roger Malo (413)587-1244 Electrical Utility: NATIONAL GRID Code Ref: NEC 2020(MA) �I PROJECT NOTES 4 , ❑ ❑ c 'a UTILITY SERVICE METER - ti� II." _ SOLAR PV DISCONNECT - - -. .. (OUTSIDE) Fr.. d MAIN LOAD CENTER SITE PLAN& " MAIN SERVICE DISCONNECT PROJECT INFO. ' SOLAR PV EQUIPMENT Rev.. 9 - (BASEMENT) DATE- rn12022 BY RTC NO SCALE - - ii SOLAR ARRAY(ROOF) SCALE ''�r� SIZE 11317 N OWNMAP . OSITE PLAN PV-M 1 NOT TO SCALE NOT TO SCALE N K Roof 428• x $n u, otbrw X Array 363" X Q ^�O —� -- (I) m m �T • s° —r PV SQUARED SOLAR co m x - (1T)204 (14)161• — X G — -- - 1- { -- — — — 311 WELLS STREET,SURE e GREENFIELD.MA 01301 n _ •. • _ ®1 a)— —� WWW.PJSOIIARED.CGOP Jtl __ _' --1- .,3.m-8TE8 �._..--1. I I I 1 1 MICHEL NORTHAMPTON N I. I • - -I • I 95 RIDGEWOOD TERRACE I. NORTHAMPTON.MA 01050 O III I - I . I I .I 1 II I ; I I . SUNMODO NANOMOUNT BASES INSTALL ON DECKING RAIL MAX.48'OC RAFTERS 16"OC ®ARRAY LAYOUT 5 SCREWS PER BASE B SCALE:VC_,' ROOF SPECIFICATIONS: ATTACHMENT SPECIFICATIONS Material: Asphalt Shingles Bases/Flashing: Sunmodo Nanomount Attachment Structure Decking/Rafters Fasteners: DF#14-10 x 2"Type AMP or Similar �. Pitch 38° Sealant: Chemlink M-1 or Approved Alt. Azimuth 200' Max.Spacing: 48" 'Ir — — — MODULE SPECIFICATIONS: ' 4. MODULE MODEL. REC360AA Black Dimensions: 67.76'x 40'x 30mm — — . Clamp Long Side: 8 1/8'-23 3/4- ARRAY NOTES tIn ,_ -_ _ Clamp Short Side: 3 7/8"-9 3/4' 1. Framing and attachment locations to be verified on site. Are2. Bases are staggered to distribute point loading except at edges of ARRAY LAYOUT — _ — — 1- 94 RAIL SPECIFICATIONS array. Make&Model: Ironridge XR100 3. Additional or altemative bases may be used to meet actual roof &ROOF DATA Clamp Torque: 80 in-lbs conditions. .i —137t- L-Foot Torque: 250 in-lbs 4. Ironridge Rail Gap Spacing: REV. o DATE" 7/7/1022 Max Span: 92' 4.1. 3/8"Horizontal Spacing SP. RTC Max Cantilever: 36' 4.2. 1/4"Vertical Spacing 3 SCALE AS SHOWN 116 X—' 40" —,Y SIZE. 110T ®MOsuLL DUL, E DETAIL PV-M2 A t ii .tilimp-, r �• i r SOLAR'S MOST TRUSTED R E C L0, I,5 , 4• - i ,fiA l ; 1) *. '' ' — . iiiiii ii. ) 4 ,,, I i-1 1, i 4 k y 0y1 1 ! 1 •is REE ALPHoc PRODUCT SPECIFICATIONS - inter EXPERIENCE 9 Y award 375 W P 25 YEAR 19.9 /'T2 -6°' 2020 ELIGIBLE WINNER s PERFORMANCE /1 i t ® REC PRODUCT SPECIFICATIONS ..� SOLAR'S MOST TRUSTED ♦CERTIFICATIONS tnttzs[67.9to.11 IEC 61215:2016,IEC 61730:2016,UL 1703,UL 61730 ..28(1.1] 811[31.91 _ �� 455[17.9] _ -- - A .y - �, IEC 62804 PID + IEC 61701 Salt Mist • _ ��` 1000[39.41 \ /•, IEC 62716 Ammonia Resistance UL 1703 Fire Type Class 2 • 1 114.AA.- IEC 62782 Dynamic Mechanical Load 6.Ot02 y [0.241-0A1] 7. IEC 61215-2:2016 Hailstone(35mm) g ��' AS4040.2 NCC 2016 Cyclic Wind Load 0 n 15014001:2004,ISO 9001:2015,OHSAS 18001:2007,IEC62941 41 4 ( E El ry n to.z a r li[0.43t0.011 Mwertek 1 I ♦WARRANTY Rzo.sto.s:; i 1 i Standard RECProTrust o (0,8±0.021 , 1200[4721 - Installed by an REC Certified ��� Solar Professional No Yes Yes t f'- -'\t System Size All 425 kW 25-500 kW . 22.5(0.9] -. 621 t3[24.5 t0.121 Product Warrant (yrs) 20 25 25 as[t.a] + Y(Y ) - --- - - - __ - -' _,'3o[1.2] PowerWarranty(yrs) 25 25 25 Measurements in mm linl Labor Warranty(yrs) 0 25 10 ♦GENERAL DATA Power in Year 1 98% 98% 98% 120 half-cut cells with REC StaubliMC4PV-KBT4/KST4,12AWG(4mm2) Annual Degradation 0.25% 0.25% 0.25% Cell type: heterojunction cell technology Connectors: in accordance withIEC62652 Power inYear25 92% 92% 92% 6 strings of 20 cells in series IP68 only when connected See warranty documents for details.Conditions apply. Glass: 0.13in(3.2 mm)solar glass with Cable: 12AWG(4mm2)PVwire,39+47in(1+1.2m)in t MAXIMUM RATINGS anti-reflection surface treatment accordance with EN 50618 Highly resistant Operational temperature: -40...+185°F(-40...+85°C) Backsheet: Dimensions: 678x40x1.2in(1721x1016x30mm) polymeric construction(black) Maximum system voltage: 1000 V Frame: Anodized aluminum(black) Weight: 43 lbs(19.5 kg) Maximum test load(front): +7000 Pa(146 lbs/sq ft)' 3 part,3bypassdiodes,IP67rated Maximum test load(rear): -4000Pa(83.5lbs/sgft)' Junction box: n accordance with IEC 62790 Ongm: Made in Singapore ° Max series fuse rating: 25A '7. ♦ ELECTRICAL DATA Product Code':RECxxxAA Black Max reverse current: 25 A See installation manual for mountinginstructions. Power Output PMAx(Wp) 355 360 365 370 375 Design load-Test load/1.5 safety factor) to Watt Class Sorting-(W) -0/+5 -0/+5 -0/+5 -0/+5 -0/+5 r Nominal Power Voltage-VM„(V) 36.4 36.7 37.1 37.4 37.8 f TEMPERATURE RATINGS' Lo F Nominal Power Current-IM„(A) 9.77 9.82 9.85 9.90 9.94 Nominal Module Operating Temperature: 44°C(t2°C) a .71 VI Open Circuit Voltage-Va(V) 43.6 43.9 44.0 44.1 44.2 Temperature coefficient of PMA.: -0.26%/°C a Short Circuit Current-Isc(A) 10.47 10.49 10.52 10.55 10.58 Temperature coefficient ofVa: -0.24%/°C • Power Density(W/sgft) 18.9 19.1 19.4 19.7 19.9 Temperature coefficientoflsc: 0.04%/°C a v, Panel Efficiency(%) 20.3 20.6 20.9 21.2 21,4 'The temperature coefficients stated are linear values Output W ♦LOW LIGHT BEHAVIOUR Power Out P .,( P) 271 274 278 282 286 Nominal Power Voltage 34.3 34.6 35.0 35.2 35.6 Typical low irradiance performance of module at STC: x Nominal Power Current-IM„(A) 7.89 7.93 7.96 8.00 8.03 X„ • ec Open Circuit Voltage-Va(V) 41.1 41.4 41.5 41.6 41.6 N Short Circuit Current-Isc(A) 8.46 8.47 8.50 8.52 8.55 in Values at standard test conditions(STC:air mass AM 1.S,in-adiance 10.75 W/sgft(1000 W/m2),temperature 77°F(25X),based on a production W ° 2 spread with a toleranceofP V &lut3%withinonewattclass.Nominalmoduleoperatingtemperature(NMOT:airmassAM1.5,irradiance r M n �. a 800W/m2,temperature 68120k),wirdspeed3.3ft/s(1m/s).•Where xxx indicates the nominal power class(PM„,)atSTCabove. Irradiance(W/mu).. 42 d o= Founded in 1996,REC Group is an international pioneering solar energy ®` R r C company dedicated to empowering consumers with clean,affordable solar power.As Solar's Most Trusted,REC is committed to high quality, innovation,and a low carbon footprint in the solar materials and solar www.recgroup.com panels it manufactures. Headquartered in Norway with operational CI' 'El headquarters in Singapore,REC also has regional hubs in North America, w Europe,and Asia-Pacific. . Ti;k . Cut Sheet . . IRONRIDGE XR100 Rail see DeSCrl tlOn / Lenc tl Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in2 .66 Section Modulus (X-axis) 0.297 in3 .46 Moment of Inertia (X-axis) 0.390 in" Moment of Inertia (Y-axis) 0.085 in4 Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in4 1.99 APPROVED MATERIALS: 2.44 6005-16, 6005A-T61, 6105-15, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) 1 .25 Clear Part Black Part Number Number Description/Length Material Weight XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XR100, Rail 168"(14 Feet) 6000-Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60 lbs. v1.1 . . SUNM•D0 Cut Sheet We've Got Your Rack! 1. Nano Mount NanoMountT"' (Rafter) 1.97 01 0.41 0.31 (10.5J (7.81 '11, _ 0 0 1 �� oC ..�� r ,. Imo_ 1111 Material:Aluminum f (0 0o 1�1n 1 s1 Finish:Black Powder Coating 2. Nano Gasket ax' 1 root 0J 66 --- 10eso1 Material:USWR Silicone Foam Gasket with Adhesive 3. Hex Lag BoltM8X115, DIN 571, 304SS 0.1 024 Part Description: Nano Rafter Mount, Black d ��i11n1i1i1 i1i1nn1i1100 Part No.: K50044-BK1 ,,„ Material:Stainless Steel Finish:Clear Item 1 Description Qty in No. Kit 4. Sealing Washer .331D X.75X.157 1 Nano Rafter Mount Assembly 1 _ 1 • Nano Rafter Mount i • Nano Gasket i I t1l.51 I 00!6 1,0 0) 2 Lat Bolt Assembly 1 i • Hex Lag Bolt M8X115, DIN 571, 304S I • Sealing Washer.33 ID X.75 X.157 , as, Material: EPDM+ Stainless Steel D10213-V001 Dimensions shown are inches(and millimeters) Details ore subject to change without notice SUNM•L o Cut Sheet We've Got Your Rack! 1. Nano Mount NanoMount' (Decking) jeoul 0.41 0.31 110.51 �,g1 Ai& 5i e I 1 o T .F -00 00 Material:Aluminum 1010 1 ei Finish:Black Powder Coating 2. Nano Gasket - - 024 160i — 0366 -- lrI:I- 1693 0] — Material: USWR Silicone Foam Gasket with Adhesive 3. Self-Drilling Screw, #6.3 X 76 Part Description: Nano Deck Mount, Black *- 717 1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIiM. Part No.: K50044-BK2 Material:Stainless Steel Finish:Clear Item Description Qty in No. Kit 4. Sealing Washer.26lD X .50X .125 1 Nano Deck Mount Assembly 1 —^ 7_ • Nano Deck Mount �`., / • Nano Gasket i V�a4 t--- 1551 i 0..� I1 —4 11s.o1 � — lu.q 1 2 Decking Screw Assembly 4 i \\ i --- • Self-Drilling Screw, #6.3 X 76 I ‘\\ i / • Sealing Washer.26lD X.50X.125 ' ‘. — - - Material:EPDM+Stainless Steel D10214-V001 Dimensions shown ore inches(and millimeters) Details art(subject to change without notice Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 INSTALLATION CREW OPERATING POLICY This policy applies to all PV Squared employees in Massachusetts, but is particularly directed at those involved in the installation of solar electric and other renewable energy systems (licensed electrician, learner/apprentice electrician, licensed constructor supervisor, supervised carpenter and laborer). When engaged in this work as an employee of PV Squared on a PV Squared project site, activities of PV Squared employees are covered under the General Liability Insurance maintained by the Cooperative. It is the intent of this policy to provide clarity to installation situations where the applicable codes and regulations are unclear, ambiguous, or silent. It is possible that a municipal building or electrical inspector could interpret the codes and regulations in a manner that differs from what appears here. But this policy sets out, in writing, how the cooperative interprets legal work requirements and unclear details. It is an internal consensus working model, intended to be revised and improved from time to time. As a general matter, a city's or town's Building Commissioner is charged with enforcing the State Building Code, Plumbing and Gas Code, Electrical Code and Architectural Access Code. The commissioner addresses concerns about the safety, accessibility and security of construction of homes and businesses. The commissioner also enforces zoning bylaws. In accordance with Massachusetts General Law, employees of the cooperative who perform electrical tasks and activities must hold a Massachusetts journeymen's electrician license or be under the direct supervision of such licensed personnel. These tasks and activities include installing electrical wiring, conduits, apparatus, devices, fixtures or other appliances for carrying or using the electricity associated with Renewable Energy Generators (electrically active solar photovoltaic modules, wind turbine-generators, hydroelectric generators, etc.). In no circumstances shall the Massachusetts licensed journeymen have more than one learner or apprentice working with him/her or under his/her supervision. Mounting structures come in a variety of configurations and have differing functional and physical characteristics. A structural component or assembly becomes associated with electrical work as the Renewable Energy Generator is electrically bonded to the mounting structure. Unless otherwise noted in M.G.L. c.143 §§3 through §§60 inclusive, all structural work defined as follows shall not be required to be performed by a Massachusetts licensed journeymen electrician: • Structural improvements • Elements of a Renewable Energy Generator's support structure that fall under a building permit (e.g., assembly of top-of-pole mounting structure on steel pole with concrete foundation prior to execution of any required electrical bonding of the support structure and associated renewable energy generator (solar electric module) to the support structure Policy # 9 Installation Crew Operating Policy Pioneer Valley PhotoVoltaics Cooperative POLICY DOCUMENT #9 Current version adopted by the Board of Directors on April 28, 2011 • Roof-top mounting support structures including but not limited to posts, stand-offs, flashings, feet, and mounting rails • Operation of heavy equipment involved in moving, hoisting, digging and other tasks • Earth work, excavation and concrete work • Manual labor involved in moving loading and unloading of equipment • Moving, hoisting, and attaching an electrically bonded panel assembly (defined as one or more assembled and electrically bonded solar electric modules) to an existing structural support designed to host the panel assembly. Note however that construction of a panel assembly is an electrical task due to the required electrical bonding activities. Repair and Servicing of Installed Equipment Repair or replacement of an electrically bonded and/or energized renewable energy generator (e.g., installed solar electric panel) will be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician. Replacement of an installed inverter must be performed by a licensed electrician or properly supervised learner or apprentice working with the licensed electrician, if the work requires removal of AC and/or DC conduit and associated wiring that originates outside of the installed inverter (e.g., removal of external AC conduit and wiring between the inverter and point of interconnection with the on-site electrical service). Note that this activity may require a wiring permit in some local jurisdictions. This requirement also applies to the servicing of an installed inverter that involves replacement or repair of components and wiring internal to the pre-manufacturer inverter (i.e., factory installed components that were originally shipped with the inverter) even though such activity may not require a wiring permit. Replacement of an installed inverter may also be performed by a qualified technician who may or may not be a licensed electrician or properly supervised learner or apprentice working with a licensed electrician if the inverter is of a "plug and play" design. Such a qualified technician can also performed other tasks that include installation and servicing inverter-based performance monitoring systems (e.g., replacing internal communication cards, making "plug and play" ethernet connections, etc.), assuming these activities do not require creation of a new AC power source circuit to operate the communication system(s). Policy # 9 Installation Crew Operating Policy Non Electrical Work at a typical PV Squared installation: • All Material Handling tasks o Module prep and moving o Ladder lift set up o Ladder setup o Trash/recycling removal and sorting • Structural Improvements o All carpentry work • Roof Mount Array o Fall protection anchor setup and removal o Layout and mounting bases o Racking up to but not including"bonding/grounding related activities" o Leveling of racking o Sealing seams/patching roofing/additional flashing • Ground mount array o Site work, earth moving o Trenching/digging o Construction of racking up to but not including "bonding/grounding related activities" • Conduit run o Making holes in structure o Fire blocking, sealing penetrations o Stickers • Power Board o Build wall, hang plywood o Stickers • Interconnection o Stickers • Monitoring o Wifi options o Any"plug and play"devices o Programming of monitoring devices o Computer based activities • Installation completion o Final building inspections o Install pictures-See checklist o Update one line and roof drawings to reflect as built o Completion checklist o Notes for others o COC left onsite • Misc o Truck Organizing o Material List, ordering o Daily check-in o Customer interaction and training activities SQU.4 4 RF Q1:449744444t4NA PV Squared Solar I www pvsquared coop Phone:413-772-8788 I Fax:413-772-8668 311 Wells St., Ste. B I Greenfield,MA 01301 yR dr 147 £ so' MA Elec. Lic.A13764 I MA HIC 140077 Dear Town Inspections Officials, Please see our enclosed applications to permit a Solar Photovoltaic System in your jurisdiction. As you are likely aware, PV Squared is a worker-owned-cooperative B-Corp, employing 40+ people in Greenfield. We have installed thousands of PV Systems out of our Greenfield, MA Headquarters since 2002. PV Squared is committed to complying with all Commonwealth laws and regulations. Our worksite guidelines are created with the intention of exceeding all safety, electrical, and building requirements as defined by their respective jurisdictional entities. This includes the work of people from multiple disciplines, including electrical engineering, structural engineering, civil engineering, electricians, construction supervisors, roofers, and their associated helpers. We are a company that values training and education. We make certain that every individual is qualified for the roles and responsibilities that they assume. It is our policy to pay for the employees travel and training time and cost of the education, including CSL and Journeyman and Master Electrician classes. As an electrical contractor we are furthermore guided by the January 30, 2009 Massachusetts Board of State Examiners of Electricians (BSEE)judgements, and rulings that have followed. We pay strict adherence to these mandates and all electrical work is conducted by an electrician and an electrician's apprentice in a 1:1 ratio. We also understand that non-electrical tasks associated with a Solar installation can be completed by non-electrical workers, such as CSLs and others. I have attached our installation policy for your review, as well as a list of example non-electrical tasks. Should you have any questions or concerns regarding this policy or delineation of work, please let us know. We are a learning organization that is always trying to improve on what we do. Respectfully, Maya Fulford Installation Manager )/ ECTOR VSE Project Number:U1898.0025.221 June 9,2022 PV Squared 311 Wells St. Ste.B Greenfield,MA 01301 REFERENCE: Michel-Northampton Residence:95 Ridgewood Terrace,Northampton, MA 01060 PV Squared Project: 0061P00000ZZvl1 Solar Array Installation To Whom It May Concern: We have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review,we conclude that the existing structure is adequate to support the proposed solar panel i stallation. Design Parameters Code:Massachusetts State Residential Code(780 CMR Chapter 51,9th Edition(2015 IRC)) Risk Category: II Design wind speed,Vult: 117 mph(3-sec gust) Wind exposure category: C Ground snow load,Pg:40 psf Flat roof snow load,Pf:35 psf Existing Roof Structure Roof structure:2x6 rafters @ 16"o.c. Roofing material:composite shingles Roof pitch: 10:12 Conclusions Based upon our review, we conclude that the existing structure is adequate to support the proposed solar pan.1 installation. See attached calculations. The solar array will be flush-mounted (no more than 10" above the roof surface) and parallel to the roof surf ce. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. Increases in lateral forces less than 10% are considered acceptable. Thus the existing lateral force resis g system is permitted to remain unaltered. 651 W. Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801) 990-1775/F(801) 990-1776/www.vectarse.com VSE Project Number: U1 98.0025.221 ‘ „N E C TO Michel -Northampt n Residence 6/9/2022 E n e i n s E R s Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All w•rk performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contract•r must notify Vector Structural Engineering, LLC should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel confi ation match the description of the span tables. Connections shall be staggered so as not to overload any existing structural member. The design of the solar panels, solar racking (mounts, rails, etc.), the connection of the racking to the roof d electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others.Vector Structural Engineering assumes no responsibility for improper installation of the solar array. Vector Structure 1 Engineering shall be notified of any changes from the approved layout prior to installation. VECTOR STRUCTURAL ENGINEERING,LLC 'Jr 4s,e. `SN JAC'+B G P-• 404 o r -4 r� Vf No.$54'53 FSS)QNM. 06/09/2022 Jacob Proctor,P.E. MA License: 54953 -Expires:06/30/2024 Project Engineer Enclosures JSP/jtg 651 W.Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/F(801)990-1776/www.vect•rse.com