Loading...
24D-255 BP-2022-0826 196 ROUND HILL RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24D-255-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2022-0826 PERMISSIONISHEREBYGRANTED TO: Project# 2022 SOLAR Contractor: License: PIONEER VALLEY Est. Cost: 30630 PHOTOVOLTAICS 111266 Const.Class: Exp.Date:03/14/2023 Use Group: Owner: RANTI,RICHARD J & ANDRES F BONSIGNORE Lot Size (sq.ft.) Zoning: URB Applicant: PIONEER VALLEY PHOTOVOLTAICS Applicant Address Phone: Insurance: 311 WELLS ST - SUITE B (413)772-8788 375928710105 GREENFIELD, MA 01301 ISSUED ON:07/13/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 21 PANEL 7.77 KW ROOF MOUNT SOLAR SYSTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I .„2 cs- , • ,,, Fees Paid: $75.00 212 Main Street, Phone(413) 587-1240,Fax:(413)587-1272 Office of the Buildine Commissioner RECEIVED The Commonwealth of Massachusetts J U L 1 2 2022 OR Board of Building Regulations and:Stanc�ards Massachusetts State Building Code 780 CMR r MUNICIPALITY USE Building Permit Application To Construct,Repair Reriov t4' 1 1 A1coT6 fkvised Mar 2011 One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: g0 a,> x Date Applied: 1I 4R Uly `I )3 a, Building Official(Print Name) Signature D to SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessprs pipp&Parcel Numbers C 196 Round Hill Rd,Northampton MA 01060 .[�/�J J 1.1 a Is this an accepted street?yes x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Richard Ranti Northampton MA 01060 Name(Print) City,State,ZIP 196 Round Hill Rd 617-290-1839 rranti@verizon.net No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) 0 Addition ❑ Demolition 0 Accessory Bldg.0 Number of Units Other El Specify:Solar PV Brief Description of Proposed Work2:Intstallation of mounting system and 7.77kW rooftop solar array SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $30630 1. Building Permit Fee: $75 Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) 0l Total All Fees: 1 $ Check No. 0 ?heck Amount: 74. Cash Amount: 6.Total Project Cost: $30630 ❑Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-111266 03/14/2023 Daniel Gomez-Gonzalez License Number Expiration Date Name of CSL Holder List CSL Type(see below) U 43 Hatfield Street No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu.ft.) Northampton MA 01060 R Restricted I&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-772-8788 BUILDINGPERMITS@PVSQUARED.COoP I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 140077 9/15/2023 PIONEER VALLEY PHOTOVOLTAICS COOP HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 311 WELLS STREET BUILDINGPERMITS@PVSQUARED.COOP No.and Street Email address GREENFIELD MA 01301 413-772-8788 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes O No 0 SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Pioneer Valley Photovoltaics Coopertive to act on my behalf,in all matters relative to work authorized by this building permit application. SEE ATTACHMENT (A) SEE ATTACHMENT(A) Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application A true and accurate to the best of my knowledge and understanding. 7/8/2022 Print Owner's or Authorized iAgent'3Name( ektronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" DocuSign Envelope ID:BD96A6B7-2EA8-4547-9D11-D2EE1A153209 PV Squared is committed to providing a high quality product and service and we look forward to working with you on your renewable energy project. Sincerely, Pioneer Valley PhotoVoltaics Cooperative .Xtrifr„...411 Jonathan Child Design and Sales Team Attachments: A-PV Array Sketch General Terms and Conditions Right of Rescission AUTHORIZATION TO PROCEED AND SERVE AS AUTHORIZED AGENT I hereby agree to the Project as set out above, and I agree to pay the contract price according to the Terms of Payment. I further agree to the Terms and Conditions attached hereto as a part of this Proposal and Agreement. I hereby authorize Pioneer Valley PhotoVoltaics Cooperative to proceed with the above-referenced Project in accordance with this Agreement. I further authorize Pioneer Valley PhotoVoltaics Cooperative, or its designated representative, to obtain required permits for this project on behalf of the Owner. I will allow any photographs or videos of this project to be used by Pioneer Valley PhotoVoltaics Cooperative for marketing purposes. A check for the First Payment is enclosed and I am returning this Agreement within 21 days of the Proposal date. Richard Ranti 5/5/2022 I 5:44 PM EDT Printed Name Date PD--ocuSigned by: Pik Ad, ` System Owner —7J6oa.i=DASPC44az... Signature Title Make a Payment Online Proposal and Agreement#00017234 Page 7 of 13 Richard Ranti-May 3,2022 The Commonwealth of Massachusetts l _ 1- /, Department of Industrial Accidents '�►- 1 Congress Street,Suite 100 —0°1,`if Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name(Business/Organization/Individual): Pioneer Valley PhotoVoltaics Cooperative Inc. DBA PV Squared Solar Address: 311 Wells Street, SuiteB City/State/Zip:Greenfield MA 01301 Phone#:413-772-8788 Are you an employer?Check the appropriate box: Type of project(required): 1.❑� I am a employer with 48 employees(full and/or part-time).* 7. ❑New construction 2.11 I am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.[No workers'comp.insurance required.] 3.01 am a homeowner doing all work myself.[No workers'comp.insurance required.]' 9. ❑Demolition 10❑Building addition 4.❑I am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5.0 I am a general contractor and I have hired the sub-contractors listed on the attached sheet. 13.0 Roof repairs These sub-contractors have employees and have workers'comp.insurance.: 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 14.❑✓ Other Solar PV 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ant an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Ohio Casualty& Security/Liberty,and Continental Indemnity/AUW Policy#or Self-ins.Lic.#:37-592871-01-05 Expiration Date:01/01/2023 Job Site Address:196 Round Hill Rd City/State/Zip:Northampton MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. 1 I do hereby cer dfr t e ai s and penalties of perjury that the information provided above is true and correct `� ' 7/1/2022 Signatu• . .�` - \ Date: Phone#:413-7 4 87 8 1 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: A ® DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE 12/30/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Kathy Parker NAME: Webber&Grinnell PHONE (413)586-0111 FAX (413)586-6481 (A/C.No,Exti: (FAA xi No): 8 North King Street E-MAIL kparker@webberandgrinnell.com ADDRESS: ' INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURERA: Ohio Casualty/Liberty 24074 INSURED INSURER B: Ohio Security/Liberty 24082 Pioneer Valley PhotoVoltaics Cooperative,Inc. INSURER C: Continental Indemnity/AUW 28258 Attn:Kim Pinkham INSURER D: 311 Wells Street,Suite B INSURER E: Greenfield MA 01301 INSURER F: COVERAGES CERTIFICATE NUMBER: CL21123017215 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDLSUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED CLAIMS-MADE X OCCUR PREMISES(Ea occurrence) $ 300,000 X XCU Included MED EXP(Any one person) $ 15,000 A BKS57072282 01/01/2022 01/01/2023 PERSONAL BADVINJURY $ 1,000,000 GEM_AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY [PRO-T LOC 2 ODD 000 JEC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) ANY AUTO BODILY INJURY(Per person) $ B OWNED SCHEDULED BAS57072282 01/01/2022 01/01/2023 BODILY INJURY(Per accident) $ AUTOS ONLY v AUTOS X HIRED *s/ NON-OWNED PROPERTY DAMAGE $ _ AUTOS ONLY /", AUTOS ONLY (Per accident) _ X $1 k Coll Ded X $1 k Comp de Underinsured motorist $ 300,000 UMBRELLA LIAB ��,,•",•,`�",•Nici,,,•• 5,000,000 X X OCCUR EACH OCCURRENCE $ A EXCESS LIAB CLAIMS MADE US057072282 01/01/2022 01/01/2023 AGGREGATE $ 5,000,000 DED X RETENTION$ 10,000 $ WORKERS COMPENSATION X STATUTE OTH- ER AND EMPLOYERS'LIABILITY Y/N 1,000,000 C ANY PROPRIETOR/PARTNER/EXECUTIVE NIA 375928710105 01/01/2022 01/01/2023 E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below _ E.L.DISEASE-POLICY LIMIT $ Business Personal Prop $1,820,700 Commercial Property A BKS57072282 01/01/2022 01/01/2023 Installation $25,000 Transportation $75,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached It more space Is required) Worker's compensation includes MA and NY CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Evidence of Insurance ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD 1. Gommonwealth of Massachusetts i Division of Professional Licensure Board of Building Reg uplations and Standards Consti t�r&ir t)pg,rvisor C S-1 1 1266 Expires: 03/14/2023 DANIEL GOMEZ-GONZALEZ 43 HATFIELD STREET '! NOR1 HAMPTo) MA 01060 1t }'f)1Svi,t(let \t Com missioner ; 'r ,!• K. WEAL if Office of Consumer Affairs and Business Regulation 1000 Washington Street-Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: Supplement Card : 140077 PIONEER VALLEY PHOTOVOLTAICS COOPERATIVE.INC. R Expiration pin' O D/B/A PV SQUARED SOLAR 9/15I2/15/2 023 311 WELLS ST SUITE B GREENFIEI D,MA 01301 Update Address and Return Card. ICA 1 0 201105117 J 1Iiirrsttalion..neekABC/0.ledriouw./w/M* HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:Supplement Card before the eaptratlon date. If found return to: Rnlldrjon Expiration Office of Consumer Affairs slness Regulation 140077 09115/2023 1000 Washington Street ulte 71 PIONEER VALLEY PHOTOVOI.TAICS COOPERATIVE,INC. Boston,MA 02116 DMA PV SQUARED SOLAR IAAYA FULFORD l 311 WELLS S1 SUITE 8 f4'"''r4 i 4 GREENFIELD,MA 01901 Undersecretary of valid without slgftature New England Construction Engineering, PLC 436 Campbell Street (NECE) Structural Construction Solutions White River Junction, VT 05001 Jonathan Rugg, P.E. 603-903-9798 j.rugg@NewEnglandConstructionEngineering.com June 22, 2022 Mr. Robin Creamer Pioneer Valley PhotoVoltaics Cooperative, Inc. 311 Wells Street, Suite B Greenfield, MA 01301 Re: Ranti Residence, Northampton, MA NECE Project No. 22-01 T37 Dear Mr. Creamer, At your request, New England Construction Engineering, PLC (NECE) has reviewed the information that Pioneer Valley PhotoVoltaics Cooperative, Inc. (PV Squared) provided on the roof supporting structure of the Ranti residence, at 196 Round Hill Road, in Northampton, MA. The purpose of this review was to provide an opinion regarding the structure's capacity to support a proposed rooftop mounted photovoltaic (PV) array.The information that you provided is attached to this letter for reference. The house is a three-story wood framed residence with a multi-pitch roof. The roof has an existing PV array, and you are proposing to add two sub-arrays. One sub-array is to be mounted on the same side of the roof, and below the existing array. You also propose to mount PV panels on the opposite side of the peak from the exist array. The roof under your proposed PV panels has a 2/12 pitch on one side, and a 4.5/12 pitch on the opposite side. Below the 4.5/12 pitch section is a steeper pitch section of roof where you do not propose any PV. The roof has standing seam metal roofing. The roof is supported by manufactured roof trusses at 24" O.C. The third-floor ceiling is finished and the trusses cannot be observed without destroying finishes.The information that you provided includes wood roof truss design output from Truss Engineering and Universal Forest Products. These truss plans bear the seal of a Professional Engineer licensed in the Commonwealth of Massachusetts. The trusses were designed for a Top Chord Live (Snow) Load of 40psf, and a Top Chord Dead Load of 10psf. The Bottom Chord was designed for a 10psf Dead Load. The ground Snow Load for Northampton is 40psf. The Snow load for this roof is 35psf, the minimum Flat Roof Snow Load (Pf) for Northampton. The photographs you provided suggest that the house is well maintained and that the roof is performing well. There is no evidence of distress or large deflections. New England Construction Engineering, PLC PV Squared-Ranti Residence Jonathan Rugg, P.E. Northampton. MA Page 2 of 2 NECE's review and analysis included the controlling gravity load combinations (snow and dead load). In providing this review and opinion, NECE assumes that the trusses were properly installed as designed including all required bracing. Conclusion: Based on the information that you provided, I conclude that, the roof will support your proposed PV array. I base this on the following.The proposed PV panels will be installed parallel to the existing roof, eliminating additional wind load. Based on the information that you have provided on similar projects; I assume that the PV panels weigh approximately 2.3 psf. In summary, in my opinion, the roof will adequately support your proposed roof mounted PV array. Thank you for the opportunity to assist with this project. If NECE can be of further assistance, please contact Jonathan Rugg at NECE. P\,tH OF 14 ss��y Sincerely JONATHANP, RUGG No. 51982 / r1 a� L '! ' 't'CISfE0,0 4 '�3S Jonathan Rugg, P.E. New England Construction Engineering, PLC. / 20 2 Attachments: -Building Information PROJECT INFORMATION: Iy n V q R Project. RANTI#2 NORTHAMPTON a Q frmai Address: 196 ROUND HILL RD NORTHAMPTON,MA 01060 \ � . i s SYSTEM DETAILS f ,/� Total System Size: 7.77 kW DC(Solar) ,R* • s0' 6.0 kW AC (Solar) PV SQUARED SOLAR Modules: (21)LG370N 1 K-A6 31 wens STREET.SURE 8 Inverters. (1)SolarEdge 6kw HD-Wave w/RGM GREENEIELD.MA 01301 Optimizers: (21)SolarEdge S440 1%WW.w7OUARED.COCR a1>n2a7e8 DESIGN CRITERIA RANTI#2 Design Snow Load 35(psf) NORTHAMPTON Design Wind Speed 117(mph) Exposure Category B 196 ROUND HILL RD Risk Category II NORTHAMPTON.MA 01060 AUTHORITY HAVING JURISDICTION Building: Kevin Ross (413)587-1239 Electrical: Roger Maio (413)587-1244 Electrical Utility: NATIONAL GRID Code Ref NEC 2020(MA) PROJECT NOTES 0 I— 7 I I Existing PV Arrray I I I L J 116 I--1 I 1 'HA. _ •T MAIN LOAD CENTER — I�—�_� • `�„ y MAIN SERVICE DISCONNECT ! - >/ SOLAR PV EQUIPMENT �' LI Dt� /1` /77Yi (BASEMENT) \ it. 1r A SOLAR ARRAY(ROOF) — �� t; , Y•°.V UTILITY SERVICE METER SITE PLAN& • SOLAR PV DISCONNECT PROJECT INFO. • '•1- 10.. (OUTSIDE) REV 0 4 DATE. 82Y2022 II BY Ric SCALE NO SCALE SIZE 11417 N ®AERIAL MAP • ®SITEO PLSCA AN PV-M 1 ()NOT Te SCALE B NOT TLE ROOF SPECIFICATIONS: 4 9au44 Material: Standingoofi Saam Q Q Attachment Structure Roofing Seams a Pitch 20°/10° Azimuth 224°/44' _ MODULE SPECIFICATIONS: \y`_A'/ MODULE MODEL: LG370N1K-A6 X Roof 390" X ♦4 ..• Dimensions: 68.5"x 41.02"x 40mm * • •0 Clamp Long Side: 7 3/4•-15 5/8' PV SQUARED SOLAR Clamp Short Side: 0%11 3/4• ,4, Array 372 6' x RAIL SPECIFICATIONS jrArray 2751" X 31,WELLS STREET.SURE 8 B GREENFlELD.AN 01301 Make&Model: Ironridge XR100 WWWPVSOIIAREO.COOP Clamp Torque: 80 in-lbs Nst •117724766 L-Foot Torque: 250 in-lbs Max Span: 86" — - -- —— - -1- •---- I �-- RANTI#2 O ——1— NORTHAMPTON Max Cantilever: 34" —— ATTACHMENT SPECIFICATIONS , I ' (171')204'I I I • I it, I ) (17')170- " • 196 ROUND HILL RD 1 NORTHAMPTON.MA 01060 Bases: AceClamp A2N I 1 I {- I I Torque to Seams: 195 in-lbs b Torque to L-Foot 125 in-Ibs --iv -(—— — ——— — —i—— m Max.Spacing: 42" `A' i I I t I i - 1 I • I I' 1 I I ARRAY NOTES $ Z— _ ii---1---- -- I 1)7 --767—r—_6_—_r__6__ — m —@ 1. Framing and attachment locations to be verified on site. - I t I 1 2. Bases are staggered to distribute point loading except at edges of z array. ,r (1491 I ' OI ./ oil i� iM(14)4 4(3. Additional or alternative bases may be used to meet actual roof I conditions. I • I I I ! I I • 4. Ironridge Rail Gap Spacing: — —— 4 —— 4 I —�— ®= —6—-- — CD 4.1. 3/8'Horizontal Spacing ——-- —————-- —— —— — — — --- 4.2. 1/4"Vertical Spacing i - I --- --- - 1 1 I Existing PV Arrray I. 12" • I , . I 73. • j m j 4 I t_ b m m _ 1_ m 3 0) v I i —r—•,— I m D m m\ Rail ARRAY LAYOUT 1 O�•8 X 682 inamd AceClamearn Roof Seams 21"OC 2 Snow Guards Standing Seam Clamps REV. o Relocate to 8"from Drip Edge Torque to 195 in-lbs DATE. urz3rzozz 9 J- BY RTc 116 ,r-- 41" —, SCALE AS SHOWN SIZE- \/ 110i7 O 1O�U�E DETAIL ®ARRAY LAYOUT-0- PV-M2-M2 ARM��•=1 sauw A. tile%;60 •�w* . ,o` PV SQUARED SOLAR 311 WELLS STREET,SUITE S GREENWELD.MA 01001 WWWPYSOUARED.COOP 413.772279E RANTI#2 NORTHAMPTON 196 ROUND HILL RD NORTHAMPTON.MA 01060 MODULE MAP REV. 0 DATE: E23/2022 ST. RTC SC e. NO SCALE eZE 1107 PV-M4 Qu4 R 4•_ PLAQUE NOTES: a • RED BACKGROUND WITH WHITE TEXT AND LINES • ADHESIVE ON BACK OF PLAQUE ``"" •f • NUMBER NEEDED:3 4kr • so` PV SQUARED SOLAR 311 WELLS STREET.SUITE B DESIGN NOTES.(VERSION 2022-2-6) r 5• X GREENFIELD,MA 01301 WWW.PVSOUARED.CCOP 1. SET PLAQUE TEXT TO.PV ONLY/PV&ESS/ESS ONLY 113772d186 2. PLAQUE MUST BE SINGLE COLOR EXCEPT RED CUT LINE RANTI#2 3. SAVE AS SINGLE PAGE PDF(GENERAL SETTINGS) WARNING NORTHAMPTON LAYERS • PV_L-BLOCK(PLAQUE BLOCK) NORTH196 AMPTON. RD N • PV_L-CUT-LINE(RED LINE,EDGE OF PLAQUE) MULTIPLE SOURCES OF POWER ORTNAMPTON."A D1060 • PV_L-PLAQUE-LINES(VISIBLE LINES AND ELEMENTS) WITH DISCONNECTS LOCATED AS SHOWN: • PV_L-TEXT(ALL TEXT&LEADERS) • PV_L-PLAQUE-LINES(VISIBLE ENGRAVED LINES) r • PV_G-LOGO(LOGO) ]� WORK• Il,,,,,,, • RED CUTUT LINE SHOULD BE.003 PTS(CAN BE CHANGED BY ENGRAVER) • SEG IF WE CANMATLY I THE TEXT VECTOR- E OBJECTS/CAN .i,IuI,, • LOGO-CURRENTLY IS A PICTURE-SEE IF WE CAN CHANGE SETTINGS TO MAKE THE VECTOR COPY WORK i0 '-I SOLAR ARRAY(ROOF) V MAIN LOAD CENTER S SOOSTING LARR MAIN SERVICE DISCONNECT ARRAY SOLAR PV EQUIPMENT (BASEMENT) UTILITY SERVICE METER SOLAR PV DISCONNECT (OUTSIDE) FOR SERVICE AND OPERATION OF SOLAR PV SYSTEM CONTACT PV SQUARED(413)772-8788 SITE PLAQUE REV. 0 DATE. 6Q3/2022 BY RTC SCALE NO SCALE SIZE. 11.11 PV-P1 LG N ON®2 Black LG370N 1 K-A6 370W • The LG NeON°2 is LG's best selling solar module and one of the most powerful and versatile modules on the market today.The cells are designed to appear all-black at a distance,and the performance warranty guarantees 90.6%of labeled power output at 25 years. 25, C ® US • YEAR PRODUCT•PERFORMANCE•LABOR WARRANTY • • Features Enhanced Performance Warranty 25-Year Limited Product Warranty LG NeON°2 Black has an enhanced "'"" The NeON°2 Black is covered by a 25-year performance warranty.After 25 years, limited product warranty.In addition,up to$450 LG NeON°2 Black is guaranteed at least of labor costs will be covered in the rare case 90.6%of initial performance. that a module needs to be repaired or replaced. Solid Performance on Hot Days Roof Aesthetics kr_: .4 'T LG NeON°2 Black performs well on hot LG NeON°2 Black has been designed with days due to its low temperature coefficient. aesthetics in mind using thinner wires that appear all black at a distance. When you go solar, ask for the brand you can trust: LG Solar About LG ElectronicsUSA,Inc. ginLG LG Electronics is a global leader in electronic products products in the clean energy markets by offering solar PV panelsand energy storage systems.The company first embarked on a solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries In 2010,LG Solar successfully released its first MonoX•series to the market,which is now available in 32 countries.The NeON*(previous MonoX"NeON),NeON"2,NeON•2 BiFacial won the"Intersolar Llfe'S GoodAWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. LG Ne0N82 Black LG370N1 K-A6 General Data Electrical Properties(STC*) Cell Properties(MateriaVType) Monocrystalline/N-type Model LG370N1K-A6 Cell Maker LG Maximum Power(Pmax) [W] 370 Cell Configuration 60 Cells(6 x 10) MPP Voltage(Vmpp) M 35.5 • Number of Busbars 12EA MPP Current(Impp) [A] 10.43 Module Dimensions(L x W x H) 1,740mm x 1,042mm x 40 min Open Circuit Voltage(Voc S 5%) [V] 41.9 Weight 18.6 kg Short Circuit Current(1st t 5%) [A] 10.96 Glass(Material) Tempered Glass with AR coating Module Efficiency [%] 20.4 Backsheet(Color) Black Power Tolerance [%] 0-+3 Frame(Material) Anodized Aluminium "STC(Standard Test Condition)Irradiance 1000 W/m',cell temperature 25•C,AM 1.5 Measurement Tolerence of Pmax.t 3% Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes Cables(Length) 1,100mm x 2EA Connector(Type/Maker) MC 4/MC Operating Conditions Operating Temperature [°C] -40-+85 Certifications and Warranty Maximum System Voltage [v] 1,000(UL/IEC) IEC 61 21 5-1/-1-1/2:2016,IEC 61730-1/2:2016, Maximum Series Fuse Rating [A] 20 UL 61730-1:2017,UL 61730-2:2017 Mechanical Test Load"(Front) [Pa/psf] 5,400 Certification Certificatione ISO 9001,ISO 14001,ISO 50001 Mechanical lest Load*(Rear) [POPS{] 4,000 OHSAS 18001 •Based on IEC 61215-2-.2016(Test Load-Design Load x Safety Factor(1 5)) Salt Mist Corrosion Test IEC 61701:2012 Severity 6 Mechanical Test Loads 6,000Pa/5,400Pa based on SC 61215:2005 Ammonia Corrosion Test IEC 62716:2013 Module Fire Performance Type 2(UL 61730) Packaging Configuration , Fire Rating Class C(UL 790,ULC/ORD C 1703) Number of Modules per Pallet [EA] I 25 Solar Module Product Warranty 25 Year Limited _ Number of Modules per 40'Container (EA] 650 Solar Module Output Warranty Linear Warranty` -- ------ ----. -. Number of Modules per 53'Container [EA] 850 "Improved.1"year 98.5%,from 2-24th year.-0.33%/year down,90 6%at year 25 -- Packaging Box Dimensions(L x W x H) [mm] 1,790 a 1,120 x 1,213 Packaging Box Dimensions(Lx W x H) [in] 70.5 x 44.1 x 47.8 Temperature Characteristics Packaging Box Gross Weight [kg] 500 NMOT. [•C] 42±3 - --- - -- - -i Packaging Box Gross Weight (lb] 1,102 Pmax [%PC] -0.35 Voc [%PC] -0.26 Isc [%PC] 0.03 Dimensions(mm/inch) `NMOT(Nominal Module Operating Temperature)Irradiance 800 W/m',Ambient temperature 20Y, Wind speed 1 m/s,Spectrum AM 1.5 1042 0/41 0(Sue of short side) Electrical Properties(NMOT) 1 002 0/39 4(Distance bet worn Grounding a Mourning Holes) Model LG370N1K-A6 400/1Sr Maximum Power(Pmax) [W] 277 -. 175.0/6.9 y7 f 16-8.0x3.0/0.3x0.1 • MPP Voltage(Vmpp) [V] 33.3 Drain Holes MPP Current(Impp) [A] 8.32 8.04.3/02 orovruiry Junction Box • Open Circuit Voltage(Voc) M 39.4 s-asxlz0/0.3x0.5 Short Circuit Current(Isc) [A] 8.81 Mounting Holes C C I-V Curves g .),,,433 �' r.mi,.irrlgth 12.0- g t OOOW i e 8.0 600W S 6.0 E 400W 8 0 Lj 4.0 200W . . � zo- + 0.0 .0 - o0 0.0 5.0 10.0 15.0 20.0 250 30.0 35.0 40.0 45.0 iri Voltage[V) r / .• • \ _ LG Electronics USA,Inc. Product specifications are subject to change without notice. LG Solar Business Division LG370N1 K-A6.pdf L'J 2000 Mlllbrook Drive 020221 Lincolnshire,IL 60069 Life's Good wwwlg-solaccom ©2021 LG Electronics USA,Inc.All rights reserved CutSheeI5O56-N 1 'ri Double Lock Sna• Lock A2N® SSMR Clamp Pre-assembled clamp allows for easy torque installation Non-penetrating sliding pin design does not damage the panel 111 High wind-load resistance 4 �y Available for two or three-hole brackets : < Engineered for snow retention systems _ on double or snap lock SSMR t hi*: —. lio, i e 2.270" .820 •.. 1.590 _.}._ 111 ` . 6° I I I .58" -- 1.50" 9/16" HEX HEAD ACEaproductof 87 Spring Lane I Plainville, CT 06062 CL AMP PMC Industries�c 860-351-0686 MADE DI Tlig USA *Photos shown are for representative purposes only. Actual product may vary.Design subject to The PROOF Is On The ROOF TM change without notice.Additional panel profiles&torque specs:www.aceclamp.com V11119 IRONRIDGE XR100 Bonded Splice I XR-100 RAIL /14 12.0 :, I O XR-100-SPLC-BD KIT, XR100 BONDED SPLICE li .; ivp 1) Splice, XR100, Mill 12" long 2) Screw, Self Drilling f _,,,ll 1.24 --0-- .63 --*- 1.93 j .31 poi 'N.....1 illi1111W 0.42 .15 .93 #12-14 TYPE "B"THREAD Property Value Property Value Material 6000 Series Aluminum Material 300 Series Stainless Steel Finish Mill Finish Clear vl.o IRON RIDGE XR100 Rail See Descri.tion / Length Rail Section Properties Property Value Total Cross-Sectional Area 0.582 in2 .66 Section Modulus (X-axis) 0.297 in3 1.46 Moment of Inertia (X-axis) 0.390 in° Moment of Inertia (Y-axis) 0.085 in° Torsional Constant 0.214 in3 Polar Moment of Inertia 0.126 in° 1.99 APPROVED MATERIALS: 2.44 6005-T6, 6005A-T61, 6105-15, 6N01-T6 2.34 (34,000 PSI YIELD STRENGTH MINIMUM) ,58 1.25 — Clear Part Black Part Description/Length Material Weight Number _ Number XR-100-132A XR-100-132B XR100, Rail 132"(11 Feet) 7.50 lbs. XR-100-168A XR-100-168B XRIOQ Rail 168"(14 Feet) 6000-Series 9.55 lbs. XR-100-204A XR-100-204B XR100, Rail 204"(17 Feet) Aluminum 11.60 lbs. v1.1 ll