Loading...
23D-061 (10) BP-2022-0610 18 LONSDALE AVE COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 23D-061-001 CITY OF NORTHAMPTON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-0610 PERMISSION'S HEREBY GRANTED TO: Project# CHIMNEY LINER Contractor: License: Est. Cost: 6995 CORY J MCGILL 107658 Const.Class: Exp.Date:05/25/2023 MACDONALD CATHERINE M&CHARLOTTE Use Group: Owner: ANN CAPOGNA &J KIM Lot Size (sq.ft.) Zoning: URB Applicant: CORY J MCGILL DBA DONE RIGHT CHIMNEY Applicant Address Phone: Insurance: PO BOX 1054 (413)340-1399 WCV 01525600 WILLIAMSBURG, MA 01096 ISSUED ON:06/01/2022 TO PERFORM THE FOLLOWING WORK: CHIMNEY LINER POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I' ' ",a 1 . • ' I Fees Paid: $65.00 212 Main Street,Phone(413) 587-1240,Fax:(413)587-1272 Office of the Building Commissioner ; ice / . The Commonwealth of Massachusetts % i4 y ' a,, Board of Building Regulations and Stand ds 3 / F02 !V%, Massachusetts State Building Code,780 �2 M Cij'ALITY o,_n USE Building Permit Application To Construct,Repair,Renovat. f Q o,I iced Mar 2011 One-or Two-Family Dwelling °�,rla r�orvs This Section For Official Use Only Build Permit Number: (2 O-' ?7. -G[ I v Date Applied: inEVIL) ZS � I' 1-2022 Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 18 Lonsdale Avenue 3 n 00 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) • From Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public CIPrivate 0 Zone: — Outside Flood Zone? Municipal❑ On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Cat MacDonald Northampton, MA 01062 Name(Print) City,State,ZIP 18 Lonsdale Avenue (413) 320-8390 catmacd@gmail.com No.and Street Telephone Email Address " .. SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) ❑ Addition 0 Demolition ❑ Accessory Bldg.0 Number of Units Other V Specify: Chimney Re-Lining Brief Description of Proposed Work':To install 6"x 25', Elite Series Stainless 316 Steel Tee Liner Kit, prelnaulated, into existing masonry chimney, after completing a Level 2 Inspection, to allow future installation of a wood stove. SECTION 4:ESTIMATED CONSTRUCTION COSTS > Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 6,995.04 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees:$ Check No.)'` Check Amount: lJ"J Cash Amount: 6.Total Project Cost: $ 6,995.04 o Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) CS-107568 05/25/2023 Cory McGill License Number Expiration Date Name of CSL Holder P.O. Box 1054 List CSL Type(see below) U No.and Street Type Description Williamsburg, Ma 01096 U Unrestricted(Buildings up to 35,000 Cu.ft.) R Restricted 18.2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 413-340-1399 Donerightchimneyservices©gmail.com I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) 178722 08/27/2022 Cory McGill HIC Registration Number Expiration Date HIC Company Name or MC Registrant Name P.O. Box 1054 Donerightchimneyservices@gmail.com No.and Street Williamsburg, Ma 01096 413-340-1399 Email address City/Town,State,ZIP Telephone SECTION 6:WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes p( No 0 SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Cory McGill to act on my behalf,in all matters relative to work authorized by this building permit application. Cat MacDonald A-t-kieus 5 /L7%21-- Print Owner's Name(Electronic Signature) ate SECTION 7b:OWNER1 OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is trye and accurate to the best of my knowledge and understanding. • Cory McGill /7�1 s � . 7/9 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at kwnv.mass.aov/dns 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts "'*`'� — Department of Industrial Accidents 1, h 1 Congress Street,Suite 100 _m f_ Boston,MA 02114-2017 www.mass.gov/dia Workers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual): Done Right Chimney Address: P.O. Box 1054, 45 Main Street, Unit B city/state/zip:Williamsburg, Ma 01096 Phone#413-340-1399 Are you an employer?Check the appropriate box: Type of project(required): l.®I am a employer with 3 employees(full and/or part-time).* 7. ❑New construction 2.0 I am a sole proprietor or partnership and have no employees working for me hi 8. 0 Remodeling any capacity.[No workers'comp.insurance required.] 3.0 I am a homeowner doing all work myself.[No workers'comp.insurance required.]i 9. ❑Demolition 10[j Building addition 4.01 am a homeowner and will be hiring contractors to conduct all work on my property. I will ensure that all contractors either have workers'compensation insurance or are sole 11.0 Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5.❑I am a general contractor and 1 have hired the sub-contractors listed on the attached sheet. 13.0Roof repairs These sub-contractors have employees and have workers'comp.insurance.$ 6.0 We are a corporation and its officers have exercised their right of exemption per MGL c. 14. Other Chimney Re Lining 152,§1(4),and we have no employees.[No workers'comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. fi Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. (Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Atlantic Charter Insurance Company Policy#or Self-ins.Lic.#: WCV 01525600 Expiration Date: 06/28/2022 Job Site Address: 18 Lonsdale Avenue City/State/Zip: Northampton, MA 01062 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certj under tthe�is and penalties of perjury that the information provided above is true and correct Signature: , P /�_Z G Date: c/k;? Phone#: "+�'.�-340-1399 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 18 Lonsdale Avenue, Northampton, MA 01062 The debris will be transported by: Done Right Chimney The debris will be received by: Valley Recycling 234 Easthampton Road, Northampton, MA 01060 Building permit number: Name of Permit Applicant Cory McGill dba Done Right Chimney 57)7 /144 /4 Date Signature of Permit Applicant INSTALLATION INSTRUCTIONS Phone:888 900 8106 FOR BEST-Flex Model "PI" Pre-Insulated Fax:888 392 4432 isi MIN INN III a STAINLESS STEEL CHIMNEY LINERS WeIb":www.NewEnglandChimneySupply.com 34 Commerce Street,Williston VT 05495 BEST-Flex Model "P Pre-Insulated BeTS New England Supply PRODUCTS STAINLESS STEEL CHIMNEY LINERS BEST-Flex Model"PI"Stainless Steel Chimney Liners are manufactured by New England Supply Inc. Located in Williston,VT. The BEST-Flex lining system is designed and UL listed to be installed inside masonry chimneys. BEST-Flex liners are used to vent the gases and by-products produced by appliances that burn oil,gas,or solid fuels. All appliances require certain venting specifications and the liner is not to be sized less than specified in the appliance manufacturer's instructions.For the best operation refer to the appliance manufacturer's instructions to determine any special necessities for that specific appliance. The installer must contact the local building and fire code officials for a variety of reasons: • The installation may require special inspection requirements. • Building permits may be required before installation. • Compliance with local building codes. (Authorities with local jurisdiction such as Inspectors,Municiple Building Departments, Fire Departments,and Fire Bureau's have precedence over national codes). For proper results and operation use only materials or components specified in these installation instructions. Using parts or materials not specified may result in undesireable effects. The lining system safety,code compliance,warranty and performance may be compromised if the installation instructions are not followed BEST-Flex Stainless Steel Chimney Liners are tested and listed by Underwriters Laboratories. • In the United States they are tested to UL 1777 and can be installed in NEW&EXISTING masonry chimneys. • In Canada they are tested to ULC S635 and are to be installed in EXISTING masonry chimneys. PRODUCT INFORMATION FOR BEST-Flex CHIMNEY LINERS • BEST-Wrap and a protective aluminum sleeve has already been assembled around the liner • BEST-Wrap is one half inch(1/2")thick,eight pound density,ceramic wool blanket with a three mil aluminum foil face. • Best-Flex Pre-insulated Liners are created from a variety of New England Supply's Liners;Including Best Flex Lightwall,Elite Series,Heavywall, & Smoothwall liners. • The BEST-Flex Pre-Insulated Stainless Steel Flexible Chimney liner is designed to reline existing chimneys or to be used as a liner in new construction. Manufactured with the highest quality,mill certified alloy.BEST-Flex Stainless Steel Flexible Chimney Liner has a high acid fighting capability. Listed by UL Laboratories to UL 1777&ULC S635 standards for zero clearance installation. BEST-Flex can be used to vent wood,wood pellet, coal, non-condensing gas and oil, making it the choice for venting all standard efficiency installations.UL listed BEST-Flex is available in 3"to 12"diameters(13"above is not listed)to cover a wide range of requirements found in the field today. • The unique manufacturing systems used to make BEST-Flex utilizes a continuous strip of stainless steel, interlocked to produce a gas and water tight lining system of superior strength and durability. BEST-Flex can be curved to go around offsets in chimneys and can fit most any installation requirement. Unless specified by the manufacturer,the liner is not to be field ovalized. The corrugated construction allows for expansion& contraction during the heat-up&cool-down periods,which removes any stresses on the system. • BEST-Flex Pre-Insulated Liner is already insulated with a foil-faced ceramic wool blanket&protective shell that meets UL 1777&ULC S635 standards for chimney exteriors with zero clearance to combustibles. • BEST-Flex Stainless Steel Chimney Liner comes with a Lifetime Warranty for all fuels,with appliance efficiencies at 83 percent or lower. • BEST-flex Pre-Insulated Stainless Steel Liners DO NOT need any additional insulation to meet the zero clearance inside&outside the masonry mass. MATERIALS REQUIRED FOR BEST-Flex PRE-INSULATED STAINLESS STEEL LINER INSTALLATION: Pre-Insulated Liner-"PI" / 4.,,,., SA- Stove Adapter TT/TB-Two piece or one piece tee . .1.441 44)0 s a TEC -Tee Cap EA/EF- 15°-90°elbow C/CC-Coupler Screws/Rivets OPTION A l°"" OPTION B TP Top Plate I M'°'x / TPCC Liner Cap TC-Top Clamp • itoIPC -Top PlateORSC- Storm CollarCL-Liner Cap (square/round) \ Phone:888-900-8106 Fax:888-392-4432 Web:www.NewEnglandChimneySupply.com New England Supply 34 Commerce Street,Williston VT 05495 1.)CHIMNEY PREPARATION&INITIAL INSPECTION Before any liner can be installed the existing chimney must meet proper construction and code requirements: • The chimney must be between 10-ft high(min)and 100-ft(max)in height. • The chimney must have a wall thickness of 4-inch min(nominal)solid masonry unit. • The chimney must project at least 3-ft over the point of roof penetration,and at least 2-ft higher than any point of any structure within a 10-ft radius. • If the mass of the chimney is constructed within the structure a 2-in minimum,unobstructed air space,must surround the chimney mass to any combustible material.If the chimney is constructed on the outside of the structure, 1-in of unobstructed air space must be maintained between the chimney mass and all other combustible materials. • When the chimney breaks the plane of a floor,ceiling,or other horizontal or vertical structure,fire stops of a non-combustible material must be used. • The installer must verify the above with all local&national codes as required. • If the correct clearances cannot be verified due to regional factors the liner must be installed with a UL listed insulation material. • Any appliance that burns a liquid fuel cannot be attached to a chimney liner made to vent a solid fuel burning appliance. • The connection pipe between the appliance and the chimney liner must have proper clearances to combustibles. This can be determined by the appliance manufacturer's installation instructions,the national building code,the local building code,or whichever factor takes precedence. • The chimney must be cleaned comprehensively to remove all deposits of soot,creosote,or glazed creosote before any liner is installed.A full inspection must be done to determine if the chimney is structurally sound. If the existing system is found not to be in compliance with applicable building code and/or manufacturers installation instructions,the liner shall not be installed until appropriate steps have been taken in order to bring the chimney or vent into compliance with the applicable code and/or manufacturer's instructions. Note:Installing a lining system into an existing chimney or vent does not,in any way,upgrade the resulting relined system and make it suitable for any applications that require a vent or chimney of a higher temperature handling capability,an alternative fuel,or any other more sever service than the original chimney or vent in which it is installed. 2.)GENERAL INSULATING REQUIREMENTS AND THE BEST- CHIMNEY CONNECTORS AND VENT CONNECTORS Flex PRE-INSULATED STAINLESS STEEL CHIMNEY LINER Not all situations require the insulation of the chimney liner.The UL 1777 to bwk n°a"��bles i %MOM A.rt�dbadh 3.5 in.(90 mmi truck buck masonry wall framed,mo w r tsl rs cmdawhlea I =Melolid with a nuYm rr of 12 in.(305 mn)orgy separaam zm lot mmi ;_ 12in(X6 mmarce from cloy M bc0mbonrldes Ftrecley Bner(ASTMC 3IS. &ULC S635 Standard for installing stainless steel chimney liners requires _ ,inimum mn, . d ells Sedmsjm Spec(lb rpm) lot Clay Flue Ctrs and Chimney Pots,or equivalent), insulation because the non code conforming chimney has zero clearance Masi m.,�mla%on(16mn)wasthickness.shall run hrrnouter sadace of brick wall b.but not beyond,the inner surface of chimney flue to combustibles or some other defect.Therefore the UL 1777&ULC S635 , =—r� �i liner and shall befirmy cemented in place . Chimney-1.• aa.de Standard is in place for fire protection. In the United States the definition of ff. amwdnr Clearance 12 in.(3osmn) a code conforming chimney is one that meets or exceeds the N.F.P.A.211ave 12M(306mm : i Ma standard for construction of chimneys.This standard includes;proper ^ • �a,<dMfir;--2' , clearances to combustibles,intact 5/8 fireclay flue liner or equivalent, minimum four inch(nominal)solid chimney wall.If the chimney meets all MIM mrn mimne,mamma nom System 9.Sod.Insulated listed lactory.boid chimney length oft he same Inromy to sheet sleet supports and Marron inside diameter as the chimney connector and having 1 in the requirements for a code conformingstructure the onlyreason to reline 1 a nbreedee 2 e(s1 mm) = du ern q \ !•�, seh.sp„eto (25 mel)or more 01,nsdlation aim a mmlmum 9 in.(229 mm) it would be for proper sizingand applianceperformance.In the case of Nevada air space between the outer wall of the chimney length and P P PP aao yawt west y 0kkmry cmnbushbles. relining gas or oil fired appliances no insulation is required(recommended ' '''''""rl°h Oen"'e ,,,,, 1° The inner end al the chimney length shall be Bush with the �- diei•,"Imp inside of the masonry cmmney flue and shall be sealed to the flue for high efficiency).Regardless of existing chimney conformance,insulating Ikea*t male and to the bock masonrypenetration.^mneoeat«-aok/de ' a IvaI ban chimney refractory cement Supports shalt be securely fastened to wall the chimney liner will improve the performance of the appliance that is mke wore O surfaces on all sides IIIAe paw 0nm•r ahem connector Fasteners between supports end the chimney length shall ml connected to it.The insulated liner will stay warmer and the flue will not cool sh(n eCslmin ll. securely penetrate the chimney liner Bout msuiated. as quickly which means less condensation.In wood burning appliances this ," ' e II eta Clearance:9 in.(229 min) will reduce the amount of creosote that will form in the liner. In oil and gas Sheet Val epwwM burning applications the likelihood of condensation will be greatly reduced (especially on startup).While fire protection is the main reason for insulating, ,Ye ,0ee„t_, System C.Sheet steel c rnneyconrnect«,minimum24gauge(0024n insulatinga liner(even if not required)will paydividends byincreasing '""51mei) wi°"m"' (0.61 nenpintdatnesa.with e ventilated thimble,nnnamum q ) z.to mmi T oekaam ea 24 gauge[0.024 in(061 mmp m thickness,harirg two tin. aatll 1 In 125 mnhl (25 min)au channels,separated from oomoustibles a reesmum performance and efficiency. �� �\ 1 0l 6 m.(152 min)of glass fiber msofat,ne Opening shad be moaned Please Note: For the installed liner system to meet UL standards,all UL r �11 and(tumble supported weh a sheet steel support,mmmum 24 gauge (0.024 in.(0.61 rung in thickness listed components used must be installed with proper clearances. 1# Supports shall be securely festered to wall surfaces on all odes pps Unease a m and shall be sized to le and hold chimney section.Fasteners used Cni MO I noa (152 min)decs to secure chimney section shall not penetrate chimney flue liner. Teo metaled a fl1e - liar IwlAaarn 3.)SIZING THE CORRECT CHIMNEY LINER DIAMETER darnels,each T;1 Clearance: in(152 nor) • Any heating appliance connected to the lining system must not • ol MNFe5211 6 daNa ppme have a flue outlet size larger than the liner area at its smallest point,unless a qualified person has sized the liner to suit thence Warm,,oombamas 2 a.(at well Bosht�,�supportd ,� Syatdmo.Solid-insulated,lted,aotory�adt chimney length web aninside appliance diameter 2 In.(51 rum)larger than the chimney connector and having PP 1 In(25 mm)or more of insulation.serving as a pass-through bra single k , Sleet•I /Masse donna 2le(61 ken) wad sheet steel chimney connector of minimum 24 gauge[0 024 in • For sizing a liner used for gas and oil burning appliances refer ncsmM (0.61 mmp thickness.with amnmum2 n.(51mm)air space between the to N.F.P.A 54 for gas and N.F.P.A 31 for oil.Also refer to the 1.=. aam.r NM .. lodam length space outer wall 0l chimney section and 0ombusades. WW1 �' M p h Minimum length of chimney section shad be 12 m.(305 min).Clammy appliance manufacturer's instructions.Liners that are incorrectly section concentric with and spaced I in(25mm)away horn connector by sized for the appliance can lead to poor draft,excessive Chewy means of sheer sleet support plates on both ends of chimney section �.aap ' Opening ssaboe covered.and o.mneysect ,supported on both sales with �, �._ a common( sheer steel supports of minimum 24 gauge[0 024 in.(0.61 melt)thickness condensation,and creosote build-up inside the lining system. \,_, ONww length Supports shall be securely fastened to wall surfaces on all sides Please call New England Supply Inc.shouldyou have anyA space2m(61 inn) and secure be coed sec and hold ebmneyate chi Fasteneyfl ersell used g pp y ,,,„m,,,, ____ SMeI enM MlpomM to secure chimney section shall not penetrate chimney flue liner. questions about sizinga liner. ea'"°"'"to """ clearance z in.(51 mm) • For sizing a liner used for solid fuel burning appliances the cross section area of the liner shall not be less than the cross section Note All clearances and thicknesses are minimums;larger clearances and thicknesses are pemnited. area of the appliance outlet collar.Unless specified by the appliance the cross section area of the flue shall not be more than three(3)times the cross section area of the appliance outlet collar. Solid fuel burning fireplace liners should be a minimum of one-twelfth(1/12)the square inches compared to the square inches of the fireplace opening.This one-twelfth(1/12)number can vary based on height of the chimney along with other calculating factors.Call New England Supply Inc.if you have any questions.