Loading...
24A-207 (2) BP-2022-0639 17 MURPHY TERR COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24A-207-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-0639 PERMISSIONISHEREBYGRANTED TO: Project# SOLAR 2022 Contractor: License: Est. Cost: 38000 EMPOWER ENERGY SOLUTIONS 019944 Const.Class: Exp.Date: 12/01/2023 Use Group: Owner: M KING BRADLEY C&KATHLEEN Lot Size (sq.ft.) Zoning: URB Applicant: EMPOWER ENERGY SOLUTIONS Applicant Address Phone: Insurance: 30 OLD KINGS HWY S#1001 (475)221-2356 WC533SB2191Q011 DARIEN, CT 06820 ISSUED ON:06/06/2022 TO PERFORM THE FOLLOWING WORK: INSTALL ROOF MOUNT SOLAR -34 PANELS, 13.6KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: ' 3-1i • Fees Paid: $75.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner 17 MURPHY TERR EP-2022-0423 Map:Block:Lot:24A-207- COMMONWEALTH OF MASSACHUSETTS 001 Permit: Elect Renovations CITY OF NORTHAMPTON Res PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) ELECTRICAL PERMIT Permit# EP-2022-0423 PERMISSIONIS HEREBY GRANTED TO: Project# SOLAR 2022 Contractor: License: Est. Cost: 38000 EMPOWER ENERGY SOLUTIONS 20559A Exp.Date:07/31/2022 Owner: KING BRADLEY C&KATHLEEN M Applicant: EMPOWER ENERGY SOLUTIONS Applicant Address Phone: Insurance: 30 OLD KINGS HWY S#1001 (475)221-2356 019944 DARIEN, CT 06820 ISSUED ON: 06/06/2022 TO PERFORM THE FOLLOWING WORK: INSTALL ROOF MOUNT SOLAR -34 PANELS, 13.6KW Call In Date: Date Requested Inspection Date/SignOff: Reinspect?: Trench/UC: Special Instructions x Rough x Special Instructions: Final: SRE Called In: Signature: Fees Paid: $75.00 212 Main Street,Phone(413)587-1244,Fax(413)587-1272-Inspector of Wires 4 I JUN ► e C mmonwealth of Massachltsetts I ! 3 2022 F R ` ' 3 202 Bo: d of ':uilding Regulations and$`tans ds t IPALITY Mas.ach .etts State Building Code/�780T10 Is,su��nlNr I� P SE F;T OFB irirr*;,' .plic. ion To Construct,Repair,Renovate iq 6110 pso°Ntevise.Mar 2011 �n�THq` o CT�ON$ ne-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: GP--- a�� .' 3 Date Applied: k vu- //2 G-G-202.2. Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 17 Murphy Terrace, Northampton MA 01060 (IAaU 1.1a Is this an accepted street?yes x no Map umber Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private 0 Zone: Outside Flood Zone? Municipal 0 On site disposal system 0 Check if yes❑ SECTION 2: PROPERTY OWNERSHIP1 2.1 Owner'of Record: Brad King Northampton MA 01060 Name(Print) City,State,ZIP 17 Murphy Terrace +1-607-229-0610 bradking121@gmail.com No. and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) ❑ Addition 0 Demolition 0 Accessory Bldg. 0 Number of Units Other Eg Specify: PV Solar Installation Brief Description of Proposed Work2: Installation of a safe and code compliant,grid-tied PV solar system on an existing residential roof. 34 Panels/13.6 kw SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $ 4000 1. Building Permit Fee: $ Indicate how fee is determined: 2.Electrical $ 34000 ❑Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire Suppression) Total All Fees: $ ,Miy Check No.(})i) Check Amount: Cash Amount: 6. Total Project Cost: $ 38000 0 Paid in Full 0 Outstanding Balance Due: r_; ti of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS .._.... _ Rol• es� .' 212 Main street • Municipal Building yJi , W Northampton, MA 01060 'PSy�� .�s��'C�'. PROCEDURE FOR OBTAINING A BUILDING PERMIT FOR NEW 1 & 2 FAMILY DWELLING, ADDITIONS, POOLS, DECKS, ACCESSORY STRUCTURES, FENCES, GROUND MOUNTED SOLAR, ETC. I. Building Permit Application signed by legal owner and filled out by owner or authorized agent. 2. One set of plans and specifications of proposed work. (Digital and hard copy) 3. Site plan with location of proposed structure(s) and set backs. 4. Construction Debris Affidavit filled out and signed by applicant. 5. Worker's Compensation Insurance Affidavit filled out and signed by applicant. 6. Contractors must supply a copy of CS License, HIC Registration and proof of Liability Insurance. 7. Energy Conservation Compliance Certificate (new/ replacement windows). 8. Home Owner's License Exemption Form filled out and signed by Homeowner(if applicable). 9. Note any Conservation and/or special permit requirements (if applicable). 10. Driveway Permit (if applicable). 11. Proof of Water and Sewer entry fees paid (if applicable). 12. Trench Permit - public land by DPW/ private land by Building Dept. 13. Stretch Energy Code -all new construction will require a HERS Rater Affidavit to be submitted with permit application before issuance of permit. 14. Please provide the appropriate fee in the form of a check made payable to: The City of Northampton. SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 12A01/2023 CS-109944 Lando Bates License Number Expiration Date Name of CSL Holder List CSL Type(see below) Construction Supervisor 51 Assabet Dr No.and Street Type Description Northborough MA 01532-2600 U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted 1&2 Family Dwelling City/Town,State,ZIP M Masonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 774-249-1687 Lando.B@empowerenergy.co I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) Empower Energy Solutions Inc 198351 04/052024 HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 30 OLD KINGS HWY S#1001 operations@empowerenergy.co No.and Street Email address DARIEN CT 06820-4551 (475)221-2356 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes l I No ❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Empower Energy Solutions Inc to act on my behalf,in all matters relative to work authorized by this building permit application. 'tidy May 27.2022 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. May 27,2022 Print Owner's or Authorized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under MG.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below Total floor area(sq. ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD SIDE YARD SIDE YARD FRONT SETBACK FRONTAGE City of Northampton o .ot M`r- 5 .. si " f " Massachusetts �w`'S - ,,., A r da 4 DEPARTMENT OF BOILDING INSPECTIONS ,, IT R�` 212 Main Street • Municipal Building uti, .t, .. p a• Northampton, MA 01060 'r • st W x,l^`` CONSTRUCTION DEBRIS AFFIDAVIT (FOR ALL DEMOLITION AND RENOVATION PROJECTS) In accordance of the provisions of MGL c 40, S54, a condition of Building Permit Number is that all debris resulting from this work shall be disposed of in a properly licensed waste disposal facility, as defined by MGL c 111, S 150A. The debris will be disposed of in: 720 S Washington street North Attleboro, MA 02760 Location of Facility: The debris will be transported by: Name of Hauler: Empower Energy Solutions Inc t ' t'„t a 4- 9„ Signature of Applicant: Date: May 27,2022 The Commonwealth of Massachusetts lr {i Department of industrial.Accidents AMMO • '=` 1 Congress Street,Suite 100 M►1= ► r Y Boston,MA 02114-2017 www.mass.gov/dia 11 or kers'Compensation lasurrnce Aflidas it:BuildersdC ouiractors/EkctriciansiPlumbers. TO BE FILED WITH I HE PERMITI1NC Alf I IIORi71'. Applicant Information Please Print Letibls Name ta..ner.s^oTBanrzatiaa Individual): Empower Energy Solutions Inc Address: 30 OLD KINGS HWY S# 1001 City/State/Zip: DARIEN 9T,068204551 Phone#: (475)221-2356 Are y.tt an employer?Cheek the tapprirpriene hot: Type of project(required): LEI I ant a empkryea wish 1 _.__. .,.errrployroea(full ardor prnt-ume).• 7. 0 New construction 2,a I are a sole psuprietor or pattnershrp and have no employees working for me in lt. 0 Remodeling any capacity_[No workers'ainup.insurant reyuirtd] tO i am a humruwner doing all*tot myself.[No*oases'conga rrourmi a u iiinnt.}' g Dc~tlf011iitllS 4.(�""}I am a honaoowyrt and will be hiring tti a rime ura to to all work on my property. 1 a e8 l 0 Building addition t.. ensure that all contractors either haste workers'tesrrr¢�nmite r marmots:or are sole i l.p Electrical repairs or additions proprietors with no employees. 12.0 Plumbing repairs or additions 5C3 I am a gene-l cooties tear and I have hared the subs:urttracwan listed on the at ached sheet_ i l t Roofat►�3 These sub-eontraeturss have employees and hate notions'comatnsutancc.• L„_J 14. Other PV Solar Installation 6.0 we an a corporation arid its officers have eseru ed their right of esampuun per M(,L e. ----- I$: f l(4).and i e lime no employees.(No workers'comp.ansuratrea tenoned. "Any applicant that becks bus VI must also fill out the seceun below showing their workers'eumpenwt on policy informati,aa. Iionteun rarrs,who subsoil this affidavit indicating they are doing all work and then hire outside ccsttracte rs must xribout*new atftdav it uslitaung ankh. tConttactura that check this but nava attached an addstionut,,bent slriw,r+ing the meow of the suhcuntrn-ters and,tzte*(retire or riot thine eattrtte,base p g uwrt• ;Preis Aortas'olinp.pu3tc;iiumtr:r. ten l�.nee>. If .ul.-ccsnrrmctras havY cat i !am an employer that is providing woriter..',r,mpensaiion insurance for my employees. Below is the policy and fob.site Information. lnsutante Company Name: LM Insurance Corporation Policy#or Self-ins.Lie.#: WC533SB2191 Q011 Expiration Date: 11/03/2022 It Job Site Address: 17 Murphy Terrace City/State Zip Northampton MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the polies number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a file up to$f,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a tine of up to$250.00 a day against the violator_A copy of this statement may be forwarded to the Office of Investigations of the DiA for insurance coseraee verification. 1 do hereby certify under the pains and penalties of perjure that the information provided above is true and correct. Signature: Dale, May 27,2022 Phone . (475)221-2356 Official use unit. Do not write in this area.to be completed by city or town official Cite or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2. Building Department 3.City/Town Clerk 4.Electrical Inspector 5. Plumbing Inspector 6.Other Contact Person: Phone 4: _ City of Northampton 0- I.f‘, 0. Massachusetts � a j DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street • Municipal Building 0%, C�� Northampton, MA 01060 •. 31�`'O HOMEOWNERS'EXEMPTION ELIGIBILITY AFFIDAVIT Brad King (insert full legal Warne), born _ (insert month, day,year),hereby depose and state the following: 1. I am seeking a building permit pursuant to the homeowners' exemption to the permit requirements of the Massachusetts State Building Code,codified at 780 CMR 110.R5.1.3.1,in connection with a project or work on a parcel of land to which I hold legal title. 2. I am not engaged in,and the project or work for which I am seeking the aforementioned homeowners'exemption, does not involve the field erection of manufactured buildings constructed in accordance with 780 CMR 110.R3. 3. I qualify under the State Building Code's definition of"homeowner"as defined at 780 CMR 110.R5.1.2: Person(s)who owns a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be, a one-or two-fanuly dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a home owner. 4. I do not hold a valid Massachusetts construction supervision license and, except to the extent that I qualify for and will abide by the Massachusetts State Building('ma's requirements for the supervision of the project or work on my parcel, I am not engaged in construction supervision in connection with any project or work involving construction, reconstruction, alteration, repair, removal or demolition involving any activity regulated by any provision of the Massachusetts State Building Code. 5. If I engage any other person or persons for hire in connection with the aforementioned project or work on my parcel,I acknowledge that I am required to and will act as the supervisor for said project or work Signed under the pains and penalties of perjury on this 27th day of May , 20 22 4441 (Signature) THE COMMONWEALTH OF MASSACHUSETTS Office of Consumer Affairs & Business Regulation Registration valid for individual use only before the HOME IMPROVEMENT CONTRACTOR expiration date. If found return to: TYPE: Out of State Corporation Office of Consumer Affairs and Business Regulation Registration Expiration 1000 Washington Street - Suite 710 198351 04/05/2024 Boston, MA 02118 EMPOWER ENERGY SOLUTIONS INC5:„ * ASIM HAFEEZ 30 OLD KINGS HWY S w isss SUITE 1001 DARIEN, CT 06820 Undersecretary Not valid without signature Name Name: Lando Bates Address: 51 Assabet Drive Northborough, MA 01532 Licenses Eligible for Processing Building Licenses License Type Construction Supervisor License Status Active License Number CS-109944 Expiration Date 12/1/2023 Engineering Licenses Check Status License Type Hoisting Engineer License Status. Active License Number. HE-196329 Expiration Date 12'12021 • Empower Energy Solutions Inc. EMPOWER 15 June street, Ste 2A, Woodbridge, CT 06525 MA Contractors Registration No.:198351 F !' ;ROY SOLUTfONS RESIDENTIAL SOLAR INSTALLATION AGREEMENT Customer 1 Name: Brad King Phone: +1-607-229-0610 Email: bradking121@gmail.com Customer 2 Name: Phone: Email: Street Address: 17 Murphy Terrace Town: Northampton State: MA Zip: 01060 Solar Consultant Name: Ryan Severin Phone: +1-413-687-7894 Email: ryan.s@empowerenergy.co PRELIMINARY DESCRIPTION OF THE PROJECT AND ESTIMATE OF THE SIGNIFICANT MATERIALS TO BE USED AND EQUIPMENT TO BE INSTALLED Module Name: Triple Black Tier 1 Mod. Quantity: 34 System size (kw) 13.6 Inverter: SolarEdge Structural & Electrical Requirement: If any additional work i.e., attic bracing, electric panel upgrade, re-roof, tree removal etc. is required Llir nalysis of the site surveyor&structural engineer, an additional fee will be assessed upon the Customer. (Customer Initials) PAYMENT TERMS: The Customer agrees to pay the Company the total amount of$ 76598.83 (the"Total Price") in exchange for the System. This total does not reflect any incentives the Customer may be entitled to. Payment Method: Cash, f Financed, Financing Company Concert Financed Projects: Financed projects are subject to payment schedule terms of Customer's financier. Payments will be made directly from financier to the Company. Cash Projects Payment Schedule (Applies to Cash Projects only) Installment 1 (30%): $ due immediately. Installment 2 (70% minus$1000): $ due upon permit submission. Installment 3 ($1000): $ due day of install completion. Notes: CUSTOMER AND SOLAR CONSULTANT HAVE REVIEWED THE ABOVE INFORMATION AND THE TERMS AND CONDITIONS ATTACHED, AND AGREE TO THIS AGREEMENT: Notice to Customer: (1) Do not sign this agreement if there are any blank spaces. (2)All contractors and subcontractors performing residential contracting services in Massachusetts must be registered with the director of consumer affairs and business regulations. Any inquiries concerning the registration of a contractor or subcontractor should be directed to the director of consumer affairs and business regulations. (3)You are entitled to a copy of this Agreement at the time you sign it. (4) You may at any time pay off the full, unpaid balance due under this Agreement and in so doing you may be entitled to receive a partial rebate of the finance charges. (5)The Company has no right to unlawfully enter your premises or commit any breach of the peace to repossess goods purchased under this Agreement. (6)You may cancel this Agreement if you did not sign the Agreement at the main office or a branch office of the Company, provided you notify the Company at its main office or branch office shown in the Agreement by registered or certified mail,that shall be posted not later than midnight of the third calendar day after the day on which the Customer signs the Agreement, excluding Sunday and any holiday on which regular mail deliveries are not made. See the attached notice of cancellation form for an explanation of Customer's rights. CUSTOMER 1 iq SOLAR CONSULTANT u Signature: o /� JU,�n Date Signed: 04 / 15 / 2022 Signature: I Date Signed: 04 / 15 /2022 CUSTOMER 2 Signature: Date Signed: (Terms and Conditions attached) Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 air TERMS AND CONDITIONS THIS RESIDENTIAL SOLAR INSTALLATION AGREEMENT(this"Agreement")is made effective as of the date signed by the Customer (the "Effective Date"), between the Customer whose name and signature appears above, and Empower Energy Solutions, Inc., a Connecticut corporation (the"Company"). This Agreement relates to the installation of a certain System on the residential structure located at the address set forth above (the "Home"), which Home is owned by the Customer. 1. Installation Timeline. The Company will install or cause to be installed the System within a reasonable amount of time after execution of this Agreement but no later than 12 months from the date of a work order or last amendment to this Agreement (whichever occurs last). If a financing company is involved, the lender will require the Company to perform the installation with a required timeline. 2. System. The Company will provide the following to the Customer at the Home (collectively, the"System"): a. The Company will obtain any necessary permits,at the Company's cost. The Company is not be responsible for delays in work due to the actions of any permitting and regulatory agencies or their employees; and b. The Company will cause the complete installation of a roof mounted solar photovoltaic electric generation system, with the components and specifications set forth above (as described, the "Solar Equipment"), according to final plans and specifications to be provided by the Company and approved by the Customer. All work by the Company is brought to the existing electrical connection; once at the electrical connection point, the actual connection will need to be made by or under the direction of the electrical utility company. NOTICE: Installation of the System may require(i)drilling into various parts of the Home,and(ii)other interior or exterior work that may require access to non-visible areas. The Customer consents to the installation work described. 3. Total Price. The Customer agrees to pay the Company the Total Price in exchange for the System, on the payment terms shown above, and further agrees as follows: a. Change Orders/Extra Work. If the Customer, the Customer's agent or representative, or any governmental agency requires any changes to the System beyond what is initially agreed to by the Company,the cost for any such change will be added to the Total Price, and the term "Total Price" as used in this Agreement will mean the adjusted higher Total Price. The cost of any such change order will include direct labor, materials, subcontracts plus supervision, general conditions, overhead, and profit. The Customer will also be required to pay all expenses incurred by the Company because of unanticipated or unforeseen circumstances (such as a faulty roof or inadequate electric service). b. Cost Increases. Customer acknowledges that the System equipment and materials the Company will furnish and install are subject to cost increases. The Company will hold the Total Price for six months after execution of this Agreement or the date of the last signed amendment to this Agreement. After six months, if the cost of any equipment or material rises by any unusual amount because of circumstances beyond Company's control, including but not limited to market price fluctuations or a site audit that reveals the need for additional materials or labor, then the Company will have the right to present Customer with a change order for the with a new Total Price. Customer will have the right to accept or reject this new Total Price. If Customer does not accept the new Total Price, this Agreement will terminate and the Company will provide the Customer with a full refund of any amounts previously paid, and the parties will have no further obligations to one another. c. Ownership/Security Interest. Until the time that the Customer has paid Company the entire Total Price, the Customer grants the Company and its agents, employees, and representatives the right to enter the Home/property and remove the System in whole or in part. The Customer agrees the System are not a fixture but will remain personal property at all times until the entire Total Price has been paid to the Company. Ownership of the System will remain with the Company until the Customer has timely paid the full Total Price. To the extent the Customer may be considered the owner of the System, however, the Customer grants the Company a security interest in the System to secure payment of the Total Price and any other amounts due under this Agreement, and grants the Company the maximum rights available under applicable law in enforcing that security interest. The Company also may assert all rights under applicable state law relating to contractor/mechanic liens on real property, with respect to the Home and the Customer's property. 7 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 L /' 4. Contractor Registration. Pursuant to Mass. Gen. Laws c. 142A§ 1, et seq. all contractors and subcontractors performing residential contracting services must be registered with the director of consumer affairs and business regulations. Any inquiries concerning the registration of a contractor or subcontractor should be directed to the director of consumer affairs and business regulations. 5. Notice of Possible Mechanic's Lien. The undersigned Contractor(the Company)is about to perform work and/or furnish materials for the construction, erection, alteration, or repair upon the Customer's land at the address shown above under a Contract with the Customer. This is a notice that the undersigned Company and any other person(s) who provide(s) labor and materials for the improvements to the Customer's property under contract with the undersigned Company may file a mechanic's lien upon the land in the event of non-payment to them. It is the Customer's responsibility to assure themselves that those other persons under contract with the undersigned Company receive payment for their work performed and materials furnished for the construction, erection, alteration, or repair upon the land 6. Late Fees. The Customer must pay the Company a late fee of $150.00 on any late payment. A payment is considered a late payment if the payment is not received by the Company on or before the due date. 7. Interest on Overdue Payments. Any amount not paid when due will bear interest at the rate of 12% annually, beginning on the date that is 30 days after the due date. 8. Manufacturer Warranty.The manufacturer of the Solar Equipment and any associated components may provide a manufacturer's warranty. All warranties can be obtained by the Customer directly from the manufacturer and any claims for a manufacturer defect must be directed to the manufacturer and not the Company.The Company may assist the Customer in identifying any applicable manufacturer's warranty(ies) solely as a courtesy. THE COMPANY PROVIDES NO ADDITIONAL WARRANTY RELATING TO THE SOLAR EQUIPMENT, OTHER THAN THE LIMITED LABOR WARRANTY DESCRIBED IN THE NEXT SECTION BELOW.To the extent products, equipment, systems,or materials incorporated into the Work are specified and purchased by Customer, they shall be covered exclusively by the warranty of the manufacturer. There are no warranties that extend beyond the description of the face of any such warranty. For such incorporated items, ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED. 9. Labor Warranty. The Company guarantees that the System will be free from installation defects for a period of ten years following the conclusion of onsite installation (the"Labor Warranty"). This Labor Warranty does not cover any of the following: natural acts such as storms, winds, rain, or snow; damage covered or normally covered by homeowner's insurance such as falling tree branches, power outages, power surges; normal wear and tear of the roof, roof shingle failure, sub-structure failure,or siding or electrical system failures.The Labor Warranty also does not cover any damages caused by animals or by improper maintenance of the structure or the system or by any action of any person other than the Company. If the Customer discovers an installation defect within the Labor Warranty period, the Customer must immediately notify the Company in writing describing the nature of the defect. If the Company determines that the defect is due to defective workmanship on the part of the Company during installation,the Company will correct the defect at no additional charge to the Customer. If a part repair or replacement is required and is covered by the manufacturer's warranty, the Customer must first obtain warranty coverage from the manufacturer and only then will the Company remedy the workmanship defect. Customer will be responsible for all costs of all repairs and replacements not expressly covered by this Labor Warranty. 10. Roof Warranty. The Company, for a period of three years, warrants that, with respect to all roof penetrations made by the Company, such roof penetrations will be free from material defects in workmanship and will be sealed or flashed to eliminate any liquid or vapor penetration, and that such roof penetrations will not affect or otherwise diminish the strength, integrity, water-repelling or balance of any underlying roof structure. 11. Customer Responsibilities. The Customer agrees to provide the following in order to aid the Company in completing the System(any reference to the"Company"in this section also includes the Company's agents,employees, representatives, and subcontractors): a. The Customer must identify and stake any concealed pipes, conduits, utilities,or other equipment before the Company begins work on the System(the Customer agrees that the Customer is responsible for any damage caused to or by any concealed pipes, conduits, utilities not identified and staked as required); 3 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 o/r b. Inform the Company of any rules, regulations, restrictions, or covenants covering the Home that may impact the design and installation of the System; c. The Customer must prepare and implement a stormwater pollution and prevention plan if such a plan is required by any government agency; d. The Customer must provide prompt decision making to the Company regarding unspecified construction plans, designs, or specifications relating to the System; e. The Customer must make sure the Home is prepared for local government (city/county/town) inspection at the time of completion of the System; f. The Customer must cure any pre-existing code violations at the Home that relate in any way to the System; g. The Customer must grant and obtain all permissions require for the Company to connect the System to required utilities at the Home; and h. The Customer must make water and electrical utility services available to the Company for use in carrying out the Company's work; i. The Customer must make the Home and property available to the Company without interruption during the Company's normal working hours to permit completion of installation work. 11. Property Conditions. Customer will be responsible for the structural integrity of the location where the System are installed, including structural or electrical modifications necessary to prepare the Home for the System. The Company is not responsible for any known or unknown property conditions.The Company is not responsible and bears no liability for the malfunctioning of existing electrical equipment at the Home, including but not limited to the main electrical service panel, any major electrical devices, or any other fuses or similar devices. 12. Rebates/Incentives. Depending on the state and utility district in which Customer resides, Customer may be eligible for various state and local rebates and incentives. The rebate and incentive calculations the Company provides to Customer are estimates only. These estimates are based on certain assumptions that may not be applicable based on the circumstances specific to the System. However, actual rebates and incentives are variable as eligibility requirements, funding availability and rates may change. In an effort to assist Customer in capturing its rebate, the Company will use good faith reasonable efforts to help Customer secure applicable rebates and incentives, but the Company will have no financial obligation to Customer regarding actual rebate and incentive amounts received. Customer agrees to pay the Total Price in full regardless of the actual amount of rebates and/or incentives Customer receive. 13. Return of Goods/Equipment. If the Customer cancels this Agreement, the Customer agrees to make all goods and equipment received from the Company available to the Company for pickup by the Company, or delivery back to the Company by mail or other courier service. If the Customer cancels this Agreement at any time that is more than three business days after the date of execution, for any reason other than that the Company deems the Home not suitable for the System, then the Customer will be required to pay the Company a cancellation fee equal to $3,000.00, in recognition of the fact that the Company will immediately incur costs relating to the design and installation of the System. The Company will pay for or reimburse the Customer for any mailing/delivery expenses relating to return of the goods and equipment. The goods and equipment must be in the same condition and form as they were when first provided by the Company to the Customer. 14. Privacy/Publicity. Customer grants the Company the right to publicly use, display, share, and advertise the photographic images, project details, price and any other non-personally identifying information of Customer's project. The Company will not knowingly release any personally identifiable information about Customer or any data associating Customer with the project location. Customer may opt-out of these publicity rights by giving the Company written notice and mailing it to the Company's address on the first page of these Terms and Conditions. 15. Default/Remedies. The failure of the Customer or the Company to comply with any term in this Agreement will constitute a material default, meaning a significant breach of this Agreement. Upon default by the Customer, the Company may immediately stop all work on the System, and the Company will have all rights and remedies available under this Agreement or available at law or in equity, all such rights and remedies being cumulative and non-exclusive. 4 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 Upon default by the Company, the Customer must provide the Company with written notice,and the Company will then have 28 days in which to cure or commence the cure of the default. If the Company does not timely cure or commence cure of a default within that 28-day period,then the Customer's exclusive remedy will be to deduct the resulting damages to the Customer from the Total Price. EACH PARTY'S LIABILITY TO THE OTHER UNDER THIS AGREEMENT IS LIMITED TO DIRECT, ACTUAL DAMAGES ONLY. BOTH PARTIES AGREE THAT IN NO EVENT SHALL THE COMPANY BE LIABLE TO THE CUSTOMER FOR CONSEQUENTIAL, INCIDENTAL, PUNITIVE, EXEMPLARY, SPECIAL OR INDIRECT DAMAGES. The Company's liability to the Customer shall not exceed the Total Price, including without limitation, damages to the Home or property during the performance of installation or resulting from the System. Without limiting any of that, the parties clarify that upon termination of this Agreement by the Company for reason of Customer's default, the Company may remove any System materials or equipment from the Home, and submit to credit reporting agencies(credit bureaus)negative credit reports that would be reflected on Customer's credit record. 16. Unforeseen Conditions. The Company is not responsible for failures, delays or expenses related to unanticipated, unusual, or unforeseen conditions at the Home arising out of conditions beyond Company's reasonable control (all of which shall be considered "Force Majeure Events"). Performance times under this Agreement will be considered extended for a period of time equivalent to the time lost due to such conditions. If Company discovers unforeseen conditions requiring additional cost, then Company will present such costs to Customer and get Customer's written approval before beginning or continuing performance. If the Customer does not approve, the Company may terminate this Agreement. 17. Entire Agreement. This Agreement contains the entire agreement between the Customer and the Company relating to the subject matter addressed. No sales representative has the authority to add, delete, or modify the typed terms of this Agreement, either in writing or verbally. 18. Binding Effects/Assignment. This Agreement is binding upon and inures to the benefit of the parties and their respective heirs, legal representatives, successors and assigns. The Customer may not assign its rights or delegate its obligations under this Agreement. Any assignment or delegation by the Customer is void, meaning ineffective. The Company may assign its rights and delegate its duties under this Agreement at any time in the Company's sole discretion. 19. Attorney's Fees. In any action arising out of this Agreement, the prevailing party is entitled to costs and reasonable attorneys'fees from the non-prevailing party. 20. Risk of Loss. All risk of loss or damage to the Solar Equipment will be borne by the Customer from the moment any such Solar Equipment arrives at the Home, unless the loss or damage is caused by the negligent, reckless, or intentional acts of the Company. 21. Counterparts; Signatures. This Agreement may be executed in multiple counterparts, each of which will be deemed an original, and all of which when taken together shall constitute one and the same document and agreement. A copy or electronic transmission of any part of this Agreement, including the signature page, and any electronic signature on this Agreement or electronic copy of this Agreement will have the same force and effect as an original. 22. Indemnification. Both Parties shall indemnify, defend and hold harmless the other and its employees, officers, directors, agents and assigns from any and all third party claims, actions, costs, expenses (including reasonable attorneys' fees and expenses), damages, liabilities, penalties, losses, obligations, demands for injury to persons, including death, or damage to property,to the extent caused by the negligence or willful misconduct of the indemnifying party. 23. Governing Law. To the fullest extent possible, this Agreement will be governed by, and construed and enforced in accordance with, the laws of the state in which the Home is located, without regard to any conflicts of law issues. 24. Dispute Resolution. If the Parties cannot reach a resolution on a matter relating to or arising out of this Agreement, the Parties shall endeavor to reach resolution through good faith direct discussions between the Parties. If the Parties are not able to resolve such matter within thirty (30) days from the date of the first discussion, the Parties shall submit such matter to the following dispute resolution procedures: 5 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 a. If direct discussions pursuant to Section 27 above do not result in resolution of the matter,the Parties shall endeavor to resolve the matter by private, non-binding mediation. To the extent practicable, the mediation shall be convened within thirty (30) days of a party's demand for mediation, and shall conclude within forty-five (45) days of a party's demand for mediation. The cost of mediation shall be shared equally by the Parties. b. If the matter is unresolved after submission of the matter to mediation, the dispute shall be subject to litigation in the Superior Court in Massachusetts serving the area in which the Home is located. The Parties further agree that such the said Superior Court in Massachusetts shall have jurisdiction over each of them, and is the appropriate venue for the determination of such disputes. c. If either party to this Contract shall seek to enforce this Contract, or any duties or obligations arising out of this Contract, against the other party to this Contract, by legal or equitable proceedings, then the prevailing party in such proceedings shall receive, in addition to all other rights and remedies to which such party is entitled, such party's reasonable costs and expenses incurred in such proceedings, including reasonable attorney's fees. For purposes of this Subsection, a prevailing party is defined, to the extent applicable: (1) as a party that is awarded a net fifty-one percent (51%) of its affirmative claims, after any offsets for claim(s) or counterclaim(s) by the other party, and (2) as a party against whom an award of less than fifty percent(50%)of the opposing party's claim is granted 25. Insurance. The Customer agrees to maintain and keep in full force, during the installation of the System and up through and including final payment, property damage insurance that covers the full insurable value of the Home. The Parties hereby discharge and release each other for or on account of any and all claims and liabilities arising out of any loss or damage to any property caused by such risks as are covered by insurance and the Parties shall properly notify their respective insurance carriers that each has waived subrogation rights against the other such that the waiver is binding upon said carrier. 26. State Specific Laws. Attached hereto may be a state specific addendum/notice containing additional terms, conditions, disclosures, and/or notices, specific to the laws of the State in which the Home is located. If attached, the state specific addendum is incorporated into this Agreement by this reference. If anything in the state specific addendum conflicts with these Terms and Conditions, the provisions in the State Specific Addendum will prevail. [End of Terms and Conditions] 6 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 Notice of Cancellation 04 / 15/2022 (Date of Transaction) YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE AGREEMENT, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED.IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE COMPANY AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS AGREEMENT; OR YOU MAY IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE COMPANY REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK.IF YOU DO MAKE THE GOODS AVAILABLE TO THE COMPANY AND THE COMPANY DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE COMPANY,OR IF YOU AGREE TO RETURN THE GOODS TO THE COMPANY AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT.TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO EMPOWER ENERGY SOLUTIONS INC. AT 15 JUNE STREET, SUITE 2A, WOODBRIDGE, CT, 06525, NOT LATER THAN MIDNIGHT OF 04/22 , 20 22 . I HEREBY CANCEL THIS TRANSACTION. CUSTOMER* Signature: Printed Name: Date Signed: 7 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 Notice of Cancellation 04/ 15/2022 (Date of Transaction) YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN THREE BUSINESS DAYS FROM THE ABOVE DATE. IF YOU CANCEL, ANY PROPERTY TRADED IN, ANY PAYMENTS MADE BY YOU UNDER THE AGREEMENT, AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOWING RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED.IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE COMPANY AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS AGREEMENT; OR YOU MAY IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE COMPANY REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK.IF YOU DO MAKE THE GOODS AVAILABLE TO THE COMPANY AND THE COMPANY DOES NOT PICK THEM UP WITHIN TWENTY DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE COMPANY,OR IF YOU AGREE TO RETURN THE GOODS TO THE COMPANY AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT.TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, OR SEND A TELEGRAM TO EMPOWER ENERGY SOLUTIONS INC. AT 15 JUNE STREET, SUITE 2A, WOODBRIDGE, CT, 06525, NOT LATER THAN MIDNIGHT OF 04/22 , 20 22 . I HEREBY CANCEL THIS TRANSACTION. CUSTOMER* Signature: Printed Name: Date Signed: 8 Doc ID: 50596ec005b05f54ca24b9fbae8aca37793e95c3 Empower Energy Solutions Inc HOMEOWNERS AUTHORIZATION FORM Addendum to Contract I, Brad King (Print Full Legal Name) am the owner of the property located at address: 17 Murphy Terrace Northampton MA 01060 (Print Full Address) I hereby authorize Empower Energy Solutions Inc to act as my Agent for the limited purpose of applying for and obtaining local building, electrical and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. Customer Signature: Electronic Signature Accepted/Addendum to Contract Date: 04/ 15/2022 ftadSignature: B �` Doc ID:50596ec005b05f54ca24b9fbae8aca37793e95c3 HELLOSIGN Audit Trail TITLE MA Solar Install Agreement FILE NAME MA Solar Install Agreement(1).pdf and 1 other DOCUMENT ID 50596ec005b05f54ca24b9fbae8aca37793e95c3 AUDIT TRAIL DATE FORMAT MM /DD/YYYY STATUS Signed Document History 04/ 15/2022 Sent for signature to Ryan Severin (ryan.s@empowerenergy.co) SENT 14:56:49 UTC and Brad King (bradking121@gmail.com)from esign@empowerenergy.co IP: 70.39.251.253 0 04/15/2022 Viewed by Ryan Severin (ryan.s@empowerenergy.co) VIEWED 15:02:43 UTC IP: 71.192.25.126 �✓ 04/15/2022 Signed by Ryan Severin (ryan.s@empowerenergy.co) SIGNED 15:03:16 UTC IP: 71.192.25.126 00 04/ 15/2022 Viewed by Brad King (bradking121@gmail.com) VIEWED 15:14:26 UTC IP: 71.192.25.126 04/ 15/2022 Signed by Brad King (bradking121 @gmail.com) SIGNED 15:15:57 UTC IP: 71.192.25.126 �✓ 04/15/2022 The document has been completed. COMPLETED 15:15:57 UTC Powered by OHELLOSIGN liNirrcLIN , v CONSULTIN4 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling©wysslingconsulting.corn May 26, 2022 Empower Energy Solutions 30 Old Kings Highway South#1001 Darien, CT 06820-4551 Re: Engineering Services King Residence 17 Murphy Terrace, Northampton MA 13.600 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x6 Dimensional Lumber Framing members 16" on center. Roof Material: Composite Asphalt Shingles Roof Slopes: 12 and 25 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL= 10 PSF • Live Load = 20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed= 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110%for seismic elements. This analysis indicates that the existing framing members will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16" lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 21/2", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 21/2" embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48" on centers. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V julyycv _ Scott E. Wyssli'., PE MA License No. 505r 444,119. p50 FCr1 Signed 5/26/2022 WrSSLING LEGEND `-o E s SCALE:1"=15' M UTILITY METER INV INVERTER rAC AC DISCONNECT • 61_-. I. • MSP MAIN SERVICE PANEL ® B DC JUNCTION BOX -n O I IJ MONITORING UNIT Q cc 1 D j DISTRIBUTION PANEL w LC LOAD CENTER > DRIVEWAY = n ._.. His] AUTOMATIC TRANSFER D SWITCH ` - --. CONDUIT f. -;:. ` 1 so 1" 0 0 0 0 C FENCE • Signed'4k JOB NUMBER 1243 UTII J I Y;NG OMRIER:KING,BRAD DESCRIPfpN: KING RESIDENCE OESIGNEUSY: MS PAGEpv2 EfvLpowEp RACKING:IRONRiDGEXR-100 uTILITYACCT#:133z6-61018 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM "via1"' HA MODULES:(34)HANWHA WEAK DUO BtKML-G10400 NORTHAMPTON,MA,01060 10.00kWAC Ri,: - aTE --- INVERTER:(1)SOLAREDGE INVERTER SE10000H J JS(10.00 K 1-607-229-0610 em2022 PAGE NAME SRE PLAN Aniv BREAKER -US- FUSE —,— SWITCH INVERTER OUTPUT CURRENT(A)- 42 — EARTH G ROUPE INVERTER BACKFEED(A)- 53 ---- oIC MSP RATING(A). 200 MAIN BREAKER RATING(A). 200 ---- �6 SPREE Nuu MAX BACKFEED(A). 40 OLBINMD unun SERVICE TIE IN: LST ( METER 1 034122800 • f• M1 SOUDECK JUNCTION BOX M/BOLA/MOGI INIMER •UNPOSED M)M)MAMMA 0 PEAK DUO ELK ML•010400400WS MODULES a10000NU! -GROUNDED (SE)EOLAREDGE P770 POWER OPTIMIZERS LINE SIDE TAP N)EOAAO PECO1NEDT pORA/ODNDOI/IECT J i j/�/ -FUSIBLE.LOCKANi -PulME,LOOK/ALE I (/�/t BRANCH OF 11 J/ -BOA OG w SMART ulTeR AMPLE/II r- — 7 -'RE61>d7lT- �� _ LM! IOMD L0 LN! IOAD l ilv • /=// I r'' J moAlly � I` ------------------�� �- -tit Y //1ERANwoP1a (E)LOADS i T---- C ----I I GROUND ELROIROOE ELEC. LEAD AWORR RR'N-7 MOM TINE.. ALMOND TIMNd EMBER PAYEE IWGPR TNW/LZ EOCIOEC MAGATNWN-Z EGCAEC /GAO„0 14ARBE EOAMIEC NAG NO,TIMM,EGG -- SIGN OFF: CONDUIT.SW EMT CONDUIT,YP EMT CONDUIT,SWEET CONDUIT,EP EMT .... __ JOB NUMBER:1243 ylyET.NV DER:KING,BRAD KING RESIDENCE DESCRIPTION IDESGNED BY. MS PAGE PV5 J��l C3V31 RACIONG IRONRIDGEXR-100 UTILITY ACCT/:1332&8101a 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM MODULES:(34)HANWHAQ.PEAK DUO BLK PAL-G10400 NORTHAMPTON,MA,01060 10,00 kW AC - REV: GTE: INN8VER(1)SOLAREDGE INVERTER SE100001i11S(10.00 K 1t 1-607-229-0610 Ermoa PAVE NAME SEIGLE LIME I ABBREVIATIONS ELECTRICAL NOTES GENERAL NOTES INDEX A AMPERE 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL-LISTED AC ALTERNATING CURRENT DISCONNECTING MEANS MAY BE POWER-CONDITIONING INVERTER. PV1 i COVER SHEET BLDG BUILDING ENERGIZED IN THE OPEN POSITION,A 2. THIS SYSTEM HAS NO BATTERIES,NO UPS. CONC CONCRETE PV2 SITE PLAN SIGN WLL BE PROVIDED WARNING OF 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY C COMBINER BOX THE HAZARDS PER ART.690.17. GROUNDED. PV3 ARRAY DETAIL D DISTRIBUTION PANEL DC DIRECT CURRENT 2 EACH UNGROUNDED CONDUCTOR OF THE 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED. -- - --- EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWRE BRANCH CIRCUIT WILL BE PV4 STRUCTURAL VIEWS (E1 EXISTING IDENTIFIED BY PHASE AND SYSTEM PER PV5 SINGLE LINE EMT ELECTRICAL METALLIC TUBING ART.210.5. -- - - -- - - GALV GALVANIZED 3. A NATIONALLY-RECOGNIZED TESTING VICINITY . PV6 LABEL SET N * s GEC GROUNDING ELECTRODE CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT - .,,_,• ; GND GROUND IN COMPLIANCE WITH ART.110.3. -'� ,'q r HDG HOT DIPPED GALVANIZED �' 4- t. a�W tea----- 4. CIRCUITS OVER 250V TO GROUND SHALL S,, I CURRENT ry •' '�4y. S / '' COMPLY WITH ART. 250.97,250.92(B) `'; -T '` F s < Imp CURRENT AT MAX POWER a .. •/ . INVS INVERTERS 5. DC CONDUCTORS EITHER DO NOT ENTER "- , BUILDING OR ARE RUN IN METALLIC `�-, .� - .I* aka: b0 SHORT CIRCUIT CURRENT T RACEWAYS OR ENCLOSURES TO THE .. - -4! -,•X7- ,. - �s .p>`, kVA KILOVOLT AMPERE ��MA,EI+`" kW KILOWATT FIRST ACCESSIBLE DC DISCONNECTING f =h, 1 - . � APPLICABLE CODE -----` LBW LOAD BEARING WALL MEANS PER ART.690.31(E). I) + -. 2015 IBC Signed - '� MIN MINIMUM e. ALL VNRES SHALL BE PROVIDED MTH - ''+ ,. 2020 NEC (N) NEW STRAIN RELIEF AT ALL ENTRY INTO BOXES 'T'T . NEC NATIONAL ELECTRIC CODE AS REQUIRED BY UL LISTING. " AHJ: NIC NOT IN CONTRACT 7. MODULE FRAMES SHALL BE GROUNDED - ; ,,. _ _ r ti CITY OF NORTHAMPTON NTS NOT TO SCALE AT THE UL-LISTED LOCATION PROVIDED iks � ' 22 MAIN ST#100 OC ON CENTER p PANEL BOARD BY THE MANUFACTURER USING UL LISTED o" ' � -A NORTHAMPTON,MA 01060 PL PROPERTY LINES GROUNDING HARDWARE. + - 444WM 413-587-1240 PV PHOTOVOLTAIC 8 ALL EXPOSED METAL PARTS(MODULE - 7,.` ; _, PVC POLYVINYL CHLORIDE FRAMES,RAIL,BOXES,ETC.)SHALL BE •' S SUBPANEL GROUNDED USING UL LISTED LAY-IN LUGS a 1 °', ` UTILITY: NG SCH SCHEDULE LISTED FOR THE PURPOSE.POSTS SHALL r, �' SS STAINLESS STEEL f BE MADE ELECTRICALLY CONTINUOUS �; � �' � W V.,° �, -u� ' , SSD SEE STRUCTURAL DIAGRAMS x ',,1 Y - k - WiTHATTACHEDRAIL. L * .- EMPOWER ENERGY SOLUTION STC STANDARD TESTING CONDITIONS 9 MODULE FRAMES,RAIL,AND POSTS _ SWH SOLAR WATER HEATER s; , r• ,10-' W 30 OLD KINGS HY S#1001 , DARIEN TYP TYPICAL SHALL BE BONDED WITH EQUIPMENT - t. - ,.- _`' GROUND CONDUCTORS AND GROUNDED 5' }„ # CT,06820-4551 UON UNLESS OTHERWISE NOTED UPS UWNTERRUPTIBLE POWER SUPPLY AT THE MAIN ELECTRIC PANEL. * ., r'?* ._ ' .- LICENSES ✓ VOLT 10. THE DC GROUNDING ELECTRODE . • .4 ° • HI C: 198351 Vmp VOLTAGE AT MAX POWER CONDUCTOR SHALL BE SIZED t ° ' Voc VOLTAGE AT OPEN CIRCUIT ACCORDING TO ART.250.166(B)8 690.47 rt `� t, � - - 51 ELEC:8209-EL-A1 W WATT 'K -. fe4'..,p 9R NEMA 3R,RAIN TIGHT w JOB NUMBER 1243 UMW:IRS ER KING,BRAD DESCRIPTION ,-ti, KING RESIDENCE �;j V DESIGNED BYMS PAGE PV1�Myy�,� RAICIQNG:IRONRIDGEXI�100 uTILITYACCT# D:13326.81o1e 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM ReA�""B' HA MODULES:(34)I1ANWHAQPEAK DUO BLKML-G10400 NORTHAMPTON,MA,01060 10.00 kW AC REV DATE -607-229-0610 - . INVERTER(1)SOLAREDGE INVERTER SE10000H-US(10.00IMIp 1 RAGE"ME COVER,"EE' a iti LEGEND SCALE 1"5 t5, M UTILITY METER INV INVERTER AC AC DISCONNECT 11fA MSPI MAIN SERVICE PANEL e B DC JUNCTION BOX '71 O EH I N MONITORING UNIT w ' - ti I D I, DISTRIBUTION PANEL Ir LC LOAD CENTER r DRIVEWAY I - a. ATS AUTOMATIC TRANSFER D SWITCH II trtOf .� CONDUIT t-; P1 - - FENCE I • tMMAL 4 ' Signed 1 = N 2 JOB NUMBER 1243 UTL1Ty;NG ON KING,BRAD DESCRIPTION KING RESIDENCE: DESIGNED SY: MS P pE PV2 N EM f'1FlC RACKING:IRONRIDGEXR 100 UTILITY ACCT#:13326-61016 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM '�IE"�' MODULES tM(34)HAN -IA Q.PEAK DUO BUCML-G10400 NORTHAMPTON,MA,01060 10.00 kW AC HA nEv: DATE: INVERTER(1)SOL.AREDGE INVERTER SE10000I-I-US(10.00 Kwr 1-607-229-0610 a/mxa PAGE NAME ERE PLAN LEGEND 0 ROOF CONDUIT --. S ------_. RAFTERS INVERTER - SCALE:1„=15' AC DISCONNECT RAIL MA SMART METER MOUNT AC DISCONNECT UTILITY METER / JUNCTION BOX ®® OBSTRUCTION MAIN SERVICE PANEL TOTAL PENETRATION COUNT 110 \o- _— illrillirl MP1 „Z M P1 RAP' TER PROFILES RAFTER SPACING 1T ,IIII_■ AJ,CHMNQI 4T ATTACHMENT 0 (20) MODULES ROFSPACING ® MIIII�I ROOF TH 23' 'ARRAY PITCH 2T ROOF AZIMUTH 114' ME ® 1iIII®® ARRAY AZIMUTH110I ROOF SURFACE ASPHALT SHINGLE TYPE IIII STORIES 2 — MP2 RAFTER PROFILE 2XE _ eNI r�� RAFTER SPACING MP2 C.J.ATTACHMENT ,E• 11®1II (14) MODULES ING AnACHMENT SPACING I■■�� ROOFPIITH ,7 ARRAY PITCH 17 e f R30FAZIMUTH 111' ■■■ ' OF ARRAY AZIMUTH 114' ®�®� ROOF SUIIFACE ASPHALT SHINGLE SC TYPE vri' STORIES 2 Signed 022 ROOF LEAD y� SIGN OFF: JOB NUMBER.1243 U'TLTry;Np KIN DESCRIPTION- DESIGNED EY: 'PADS IRi KING,BRAD KING RESIDENCE MS _ PV3EKc>»- WEB RACKINQ CE IRONRID 71.100 UTILITYACCTt:1332881016 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM R"E1N8Y. MOD(LES:(34)HANWHAQPEAK DUO BLKML-010400 NORTHAMPTON,MA,01060 10.00 kW AC REV: DATE: INVERTER(1)SOLAREDGEWNERT RSE10000FWS(10.00KWt1-607-229-0610 dY2022 PAGEHWE ARRAYMTN/ y T6'.S -/ k6,. iK I 1r!--)0 VI-4 t. • ;r/ w L Signed1. : •0/J.�v A - M 1 SIDE VIEW % 1'Vr� RAFTERS:2X6 @ 16"0.b A r"«IDi:i.E MAX Spat:_15'4" �. RAIL I:FOOT GMSE;AG SHINGLE 1 I -,. / A/. - 15.^- - _.. -...1 CGRPGSPfc StiiNGLc 5':45"-LPG MP2 SIDE VIEW NTS 2s'MIN EMBEDMENT STANDOFF PER SCREW SI_ __ RAFTERS 2X6 24'O.0 SCALE NTS MAX SPAN^15'-6" 256 NOMINAL - JOB NUMBER 1243 UTILITY:NG OWNER DE$CR PTRJN: DESKiNED 6Y: PAGE KING,BRAD KING RESIDENCED MS pv4 EM�3WEp RItCIQNQROriiD0E�100 UTILITY ACCTi:13326-61016 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM REV�Ewer HA�<._Y �L`.. MODU,ES:(34)1 WW HAQPEAKDUOBMML-G10400 NORTHAMPTON, MA,01060 10.00 kW AC REV: DATE: EFt(1)SOLAREDGE INVERTER SE10000H-US(10.03 KW't1-607-229-0610 EI167.73 PAGE NAME: STRUCTURAL VIEWS _Inv BREAKER \� FUSE — 1- "NINON INVERTER OUTPUT CURRENT(A)- 42 — EARTH GROUND INVERTER BACKFEED(A)- 53 --•— ow MSP RATING(A). 200 MAIN BREAKER RATING(A)- 200 ----- EGO SINGLE PHASE MAX BACKFEED(A) 40 OVERHEAD //UT/ILITY SERVICE TIE IN: LST METE: 03922500 • • (N)SOLADECK JUNCTION BOY IN)SOLAR EDGE INVERTER •UNFUSED 7A)34)HONWHA O.PEAK DUO BLK ML-D10400 A00W I„JMODUL:S SE10000KUS -GROUNDED (K)SOLAREDGE INTO POWER OPTIMIZERS P-- LINE SIDE TAP I l'T'� PI)00A AC DISCgJNECT (N)BOA T _: J ! Z COP NA IMD \ J II '1 IR/VIp10F 11 r - -- LJNE -Lem. G - L0� lNE—LOMD �I ( / ,• i 2r / i /I/ MI I VVV N-----a-=--J *ROUND ELECTRODE ELEC. LEAD AMOR 11•IN,AZ AMER TAWS MND41IL 114NW3 MNOSH4 PVYAR MVO SS,THAN•2 EOCADEC AYW SE 1HWI.2 EOCADEC MOM TRAM.IOCIOC MOM,TNMN•2 EGG SIGN OFF: CONDUIT.3/4°EMT CONDUIT,SW EMT UTILITY: /� CONDUIT,NV EMT CONDUIT,3Ar EMT JOB NUMBER 1243 NV OWNER OE"CR PTg I: DESIGNED BY: DAUE KING,BRAD KING RESIDENCE MS PV5EMpL`WqN� RAp4fVG IRONRIDGEXRr100 UTILITY ACCT/:13326-61016 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM REVIEW ENERGY_H>Y sucU,l..lra^ HA MODULES:(34)I-IAN IAWEAKDUOBLKM.-G10403 NORTHAMPTON,MA,01060 10.00 kW AC REV DATE. INVE2TER(1)SOLAREDGEINVERTERSE10333141S(10.00K 71-607-229-0610 tY250022 PAGE tome SINGLE LIVE NOTE: NEC 690.17(E) BACKGROUND AND LETTERING COLORS FOR SIGNAGE/LABELS See Figure 690.1(b)diagrams for location in system SHALL COMPLY WITH(IN ORDER OF PRIORITY)AHJ&FIRE Disconnects PV from all other wiring systems DEPARTMENT AMENDMENTS, STATE CODE,AND ANSI Installed in a readily accessible location GUIDELINES. THIS PAGE IS INTENDED OR SIGNAGE/LABEL Permanently marked: PV SYSTEM DISCONNECT, or equivalent VERBIAGE ONLY. Where line/load may be energized in open (off)position: OUTSIDE LABELING OF SYSTEM COMPONENTS AND METERS IS Marked with the following or equivalent TO BE DONE IN A WAY SUITABLE FOR THE ENVIRONMENT IN NEC 690.31 (D) 2; 2012 IFC 605.11 WHICH THE EQUIPMENT IS INSTALLED. NO STICKERS ARE On or in a building, unless location/purpose is evident PERMITTED. WARNING Raceways, enclosures, every 10', suitable for environment 2020 NFPA 70, NEC 690.53 Minimum 3/8" CAPS White on Red, Reflective DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE Maximum system voltage calculated in accordance with 690.7 ELECTRICAL SHOCK HAZARD • At one of the following locations: DO NOT TOUCH TERMINALS • DC PV system disconnect TERMINALS ON BOTH THE LINE AND LOAD WARNING • PV system electronic power conversion equipment SIDE MAY BE ENERGIZED IN THE OPEN • Distribution equipment associated with the PV system POSITION PHOTOVOLTAIC POWER -- SOURCE MAXIMUM VOLTAGE .]•) MAXIMUM CIRCUIT CURRENT NEC 705.12(D)(2)(b) MAX RATED OUTPUT CURRENT OF PLACE THIS LABEL AT P.O.C. TO SERVICE THECHARG CON ORR DC-TO-D CC CONVERTERROER - DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL (AND 2020 NFPA 70, NEC 690.56(c) ,.,(IF INSTALLED) SUBPANEL IF APPLICABLE)) LOCATED AT EACH SERVICE EQUIPMENT LOCATION 2020 NFPA 70, NEC 690.54 WHERE PV IS CONECTED"OR APPROVED READLY VISIBLE LOCATION INTERACTIVE SYSTEM POINT OF INTERCONNECTION SHALL INCLUDE SIMPLE DIAGRAM OF BUILDING All interactive system(s) points of interconnection with other \/\I1k R N I •N G AND ROOF sources shall be marked..." Accessible location at disconnecting means, PHOTOVOLTAIC SYSTEM EQUIPPED • as a power source: WITH RAPID SHUTDOWN INVERTER OUTPUT CONNECTION TURN RAPID SHUTDOW • Rated AC output currentN Nominal operating AC voltage NOT RELOCATE THIS SWITCH TO THE"OFF" p g OVERCURRENT DEVICE P TO SHUTDOWN REDUCE SYSTEM AND PHOTOVOLTAIC AC DISCONNECT SHOCK HAZERD IN THE ARRAY — ����-'arM RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: 1 1 JOB NUMBER 1243 UTLTY:PSG OMER KING,BRAD DESCRIPTION KING RESIDENCE R. MS IDESIGNED BY. FADE: pv6 KIN E/A„p wE,-, RACKING:IRONRIDGEXR100 UTILITY ACCT#:13326-61016 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM REVEWBY' E A!f H=Y SOLI HA MODES:(„ )HAt.MHAQ.PE BL DUO NORTHAMPTON,MA,01060 10.00 kW AC UL INVERTER(1)SOLAREDGE INVERTER SE10000FWS(10.00KWT1-607-229-0610 6/2E4022 ,PAGE NAME LABEL SETS NEC 690.56(B)/705.10/712.10 2020 NFPA 70, NEC 690.56(c)(2) NEC 705.12(B)(3)(3) "AC Combiner Panel" Permanent plaque or directory installed at either: SWITCH LABELS THAT INCLUDE THE FOLLOWING: • Sum of ampere ratings, excluding source OCPD Each service equipment location MINIMUM 3/8"CAPS,WHITE ON RED,REFLECTIVE • Label applied adjacent to distribution equipment Approved readily visible location REQUIRED FOR ALL SYSTEM TYPES • The following or equivalent wording: Marked with the following wording: RAPID SHUTDOWN Denote location of each power source disconnect Grouped with other plaques or directories SWITCH FOR WARNINGCorrectly oriented with respect to diagram's location SOLAR PV SYSTEM ACAUTIO N NEC 690.35(F) THE EQUIPMENT FED BY MULTIPLE SOURCES. PLACE THIS LABEL AT EACH JUNCTION BOX, COMBINER BOX, TOTAL RATING OF ALL OVERCURRENT DEVICE, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE,' DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED SHALL NOT EXCEED AMPACITY OF BUSBAR me' M CIRCUITS MAY BE EXPOSED DURING SERVICE: JDISCAIIIIIAT LOCUMS Iw war IRMO Ut0.3TT KM WV*_ T `AI ' t -rerr n- ^'' NEC 690.56 (Informational Note) '.i..'''-' �°" WARNING • MA Fire Code (527 CMR 1) requires signage: .,BEM R- •Adjacent to building or service disconnect - ELECTRICAL SHOCK HAZARD • Identifies responsible party for operation NEC 705.12(C) OF THIS PHOTO OETDC AIC SYSTRS EMTAARE UNGROUNDED of system Equipment containing overcurrent devices AND MAY BE ENERGIZED • Provides contact informatio supplying power to busbar or conductor Supplied from multiple sources NEC 690.5(C) "Marked to indicate the presence of all sources" PLACE THIS LABEL ON INVERTER(S)OR NEAR GROUND-FAULT INDICATOR(ON INVERTER(S) U.O.N.) PV SYSTEM INSTALLATION BY: ABC SOLAR WARNING CONTACT PHONE: 857-600-8995 WARNING IN CASE OF EMERGENCY DIAL 911 ELECTRICAL SHOCK HAZARD DUAL POWER SOURCE SECOND IF A GROUND FAULT IS INDICATED, SOURCE IS PHOTOVOLTAIC SYSTEM NORMALLY GROUNDED CONDUCTORS MAY NERGIZED ,y� BE UNGROUNDED AND JOB NUMBER:1243 UTLflY:NG OKI N DESCRIPTION DES C�E0 BY IPPOE PV7 KING,BRAD KING RESIDENCE MS Epv4 EWE RACKING:IRONRIDGEXR-100 UTILITY ACCT 8:13326-61016 17 MURPHY TERRACE 13.60 kW DC ROOF SOLAR SYSTEM 1"E'IE"`�• HA MODULES:(34)HANVHA WEAK DUO BU<ML-G10400 NORTHAMPTON,MA,01060 10.00kWAC REv DATE, INVERTER(1)SOLAREDGE INVERTER SE10000H-US(10.00 Kwy-1-607-229-0610 B.�ma PbENAME: LABEL SETS pcwsmd by Q.ANTUM /Duol' Q.PEAK DUO B L K M L—G 10+ EUPa ` EUPD RESEARCH SEARCH ; TOP BRAND w rr EurD�E'TOP Y: ND PV;suncx 3 8 41O MODULES 'wpm TOP i MOM AO� 'JDUIES akakit 2017 2018 .2021. 2020 ENDURING HIGH " PERFORMANCE reimyR. GI Warranty 0 CELLS Pr dit&Palms Yield Security BREAKING THE 20%EFFICIENCY SAPPIER Fill t'I.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.1%. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY 77 Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry The new"Quality Controlled PV"of the independent certification institute TUV Rheinland. w nxjlll,;f"cr, r 4'1 \"r-r r 4rt frr.HNOLOGY Optimal yields,whatever the weather with excellent ': low-light and temperature behaviour. o,=y ENDURING HIGH PERFORMANCE: Long-term yield security with Anti LID Technology, Hot-Spot Protect and Traceable Quality Tra.QT*". High-tech aluminium alloy frame,certified for high snow(5400 Pa)and wind loads(4000 Pa). 1.PE1.IacFP1 P iNIVESTMEN.1 41 Inclusive 25-year product warranty and 25-year u linear performance warranty'. 'See date sheet on rear for further Information. THE IDEAL SOLUTION FOR: 60 lli� Rooftop arrays on residential buildings CELLSEngineered in Germany i MECHANICAL SPECIFICATION Format 1879mm x 1045mm x 32mm(tncludt0 frame) to J Weight 22.0kg u mm IOWm,. { MS_ • Front Cover 3.2mm themelly pre-sbeeaed glees with anti reflectiontechnology zeomm 4- Back Cover Compositefllm Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q,ANTUM solar heft cells C3 ,a,d,,,, Junction box 53-101 mm x 32-60 mm x 15-18 mm Protection class IP67,with bypass diodes l.en- 1 -. Cable 4met2 Solar cab*(+)a1250 mm,()k1250mm -6 `.Esismpisk• Connector StSubli MC4;IP68 4......e.torese r .„„n DETAL• 4.8_:y �ed'' 2.dmmT--. ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 410 MINIMUM PERFORMANCE AT S ANDARDTESTCONDITiL ' '';00V::: Power et MPP' P,414, (WI 385 390 395 400 405 410 E Short Circuit Current' Ise [A] 11.04 11.07 11.10 1114 11.17 11.20 £ Open Circuit Voltage' V, [V] 45.19 45.23 45,27 45.30 45.34 45.37 c Current at MPP I„W [A] 10.59 10.65 10.71 10.77 10.83 10.89 Voltage at MPP V,p, [V] 36.36 36.62 36.88 37.13 3739 37.64 Efficiency' q [%) x19.6 219.9 >20.1 x20.4 >20.6 20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONU , 1;MOT' Power at MPP Pk., [W] 288.8 292.6 296.3 300.1 303.8 307.6 E Short Circuit Current lx [A] 8.90 8.92 8.95 8.97 9.00 9.03 E Open Circuit Voltage V0 [V] 42.62 42.65 4269 42.72 42.76 4279 Current at MPP l,r. [A] 8.35 8.41 8.46 8.51 8.57 8.62 MPP Vu„ 5.._..__- [V. 34.59 34.81 35.03 3525 35.46 3 .68 'Measurement tolerances P,,,,±3%;Imo;Va t 5%at STC:1000 WAn',26±2'C,AM 1.5 according to I E C 60904-3•'800 W/rn2,NMOT,spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE 's r I '! °+.n�,.rr4....._rr At least 98%of nominal power doer- l-'ss T I i Ing first year.Thereafter max.0.5% a degradation per yea.At least 93.5% 1 ' >A L I,- L _-1._e- I of nominal power up to 10 years.At Z I least 86%of nominal power up to ' ; '° r t 1 85 25 years. ; M___r r r p t i FR t t I a - .......... _ _..... -_._ All data within measurement toler- i i t es BnCed.FW warranties in accordance M ' i ' with the warranty temts of the NS ..a ant NO sea s Q CELLS sales organisation of your MRAD1ANCE row, e a is s s as respective country. e ra..+w.s..Iowan.r. yeast 7yplcel module pert mews under low Irradiance conditions In +a...rwaa...a.0ur.w.r'a corn lso to STC conditions(25•C.1000WAn') TEMPERATURE COEFFICIENTS __. ' `__ ___-._,.....-_....._........,_.._°..._. /1(1_ +0.04 Temperature Coefficient of V,, II [%/K] -0,27 e Temperature Coefficient of P,,,,, y -,[%/K) -034,-�Nom'net Module Operating Ternperalure, NMOT ('C) 43+3 PROPERTIES FOR SYSTEM DESIGN R Maximum System Voltage V,,,; [V) 1000 PV modulo classlfIcation Mass II Maximum Reverse Currant I. tA) 20 Fire Rating based on ANSI/UL 61730 C/TYPE 2 8 2 Max.Design Load,Push/Pull [Pe) 3600/2660 Permitted Module Temperature -40"C-+85.0 Y Max.Test Load,Push/Pull [Pe] 5400/4000 an Continuous Duty 0 QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION : %hality C6t2L5:201:I PV-Tl10801Wend; `I/ y/ ® f ti' [� IEC 81215:2018;IEC 617301016, UM 0 I^I This dote sheet complies ♦ _.... 0 with DIN EN 50380, 1 01 rr. C E Horizontal 1940mm 1100mm 1220mm 751kg 28 pellets 24 pellets 32 modules o< OCPV Codification ongoing. , packaging 6 Certaceacn Adder, 0,.r�tfrr Henwha O CELLS OmbH y Nob:Installation Instructions must be followed.See the instalation and operating manual or contact our technical service department for further Information on approved Installation and .0 use of this product. is Mad•In Korea Hanwh.0 CELLS Australis Pty Ltd Suite 1,Level 1,15 Blue Street North Sydney,NSW 2060,Australia I +61(0)2 9016 3033 1.,h:. +61(0)2 9016 3032 I q-cells-australla@q-rraccorn I www.q-cells.com/au Engineered in Germany CELLS _ Single Phase Inverter Single Phase Inverter With HD-Wave Technology for North America SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ with HD-Wave Technology C SE7600H-US/SE10000H-US/SE11400H-US mMODEL NUMBER SE3000H US SE3800H US SES000H US SE6000H-US SE7600H US SE10000H-US 5E11400H US for North America T APPLICABLE N INVERTERS VR TO WITH PART SEXXXXH-XXXXXBXX4 N SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ _! ouTPUT _ _ _ —1 Rated AC Pourer Output 3300 m ZOBV 5000 0 20EN 7600 woo 0 V VA SE7600H-US/SE10000H-US/SE11400H-US _ , f n400 z4ev a" r. 'sq, m Maxenum AC Parer Output 3000 3300 0 208V 5000 5000 6 2 7600 11000 ' t000r®208V. VA <,,. T AC Outten Voltage Min.-Nom.-Max. 1 -' <. N AC Output z6y ✓ ✓ ✓ ✓ ✓ ✓ ✓ we O '�, .,. AC Output Vokage Mtn:Nom.-Max. ✓ - ✓ - ✓ ""a VI 083-208-2295 I 1 Vac AC Frequency(Nomiv¢ 59.3-60.60-N Hz • O Maximum Continuous Output Current 0210V 12.5 16 21 25 1 32 42 47.5 A Maximum Continuous Output I - Current 0218V • 16 - 24 I 48.5 A O e Pourer lector L Adjustable-0)35 to 025 O O GFD Threshold 1 A Peaty Monitodng,!:landing Protection, ,e Country Con6gurabe Thresholds l INPUT ,1ir2.'r'" ;.'� aolx.-_:" .a- • Maximum DC Paver 0240V 4650 5900 7750 i 9300 I 11800 15500 17650 W e • • .- • Maximum DC Power®21BV - 5100 - i 7750 I - - 1 15500 j W a a . a Transformer-less,Ungrounded let n • Maximum Input Voltage 480 I Vdc o a iiio Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 0240V4 8.5 10.5 13.5 16.5 20 I 27 30.5 Adc Maximum Input Current 0208V. 9 13.5 I 27 Adc Max.Input Short CAcrdt Current 45 Adc o e o 9 Reverse-Polarity Protection Yes - - • - Ground-fault Isolation Detection 6001m5er tivdy Maximum Inverter Efficiency 99 992 % 9 CEC Weighted Efiderrcy 99 I 989.5®®2e0840V V % Nighttime Power Consumption -,2.5 W Optimized installation with HD-Wave technology ..dope,reagNl saltines Ouse contact SaurEdge sown A A higher earnsi source my ore uset the inveier ail lime As Input owmt to the vela Vaud i Specifically designed to work with power optimizers # UL1741 SA certified,for CPUC Rule 21 grid compliance I Record-breaking 99%weighted efficiency I Small,lightweight,and easy to install both outdoors or indoors I Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp I Built-in module-level monitoring I Fixed voltage inverter for longer strings I Optional:Faster installations with built-in consumption metering(1%accuracy)and production revenue grade / Integrated arc fault protection and rapid metering(0.5%accuracy,ANSI C12.20) shutdown for NEC 2014 and 2017,per article 690.11 and 690.12 ' solaredge.com solar w r $ : Single Phase Inverter With HD-Wave Technology for North America SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ SE7600H-US/SE10000H-US/SE11400H-US MODEL NUMBER SE3000H US SE3800H US SES000H US SF600011 US SE7600H US SEI0000H US SE11400H US ADDITIONAL FEATURES Supported Communication Interfaces R5435.Ethernet ZgBee(optional),Cellular(optioraI Revenue Grade Metering ANSI — .. .T.. C1220 Optional* Itr Consumption metering --- Inverter Commissioning With the SetApp mobile application using Bulb-in Wr-Fi Access Point for Local Connsdion Rapid Shutdown NEC- 2014 and Automatic Rapid Shutdown upon AC Grid Disconnect 2017 690.12 STANDARD COMPLIANCE Safety UL1741,UL1141 SA,1.1116998:CSA C222.'Canadian ACCI according to Di.M-07 Grid Connection Standards IEEE1547,Rule 21 Rue 14(III) -- _ Emissions FCC Pan 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG T'Maxmum/14-6 AWG • 1^Maximum/14-4 AWG Range DC Input Conduit Size/a d Strings/ T.Maximum/1-2 t AWG Range Aga/M3 AWG 1"INdmum/1-3 strings/14-6 AWG Dimensions with Safety Switch in (hhMMD) 11Jx14.6x6B//50x370x174 21304.6x73/540x370x185 con Weight with Safety Switch 22a0 I 25.1/11A I 262/11.9 I 388/176 lei kg Nose a 25 I e50 I d3A Coding Natural Comectbn Operating Temperature Range -40 to.140/-a0 to.60A 'P/'C Protection Rating NEMA 4%(Inverter with Safety Switch) *wane,:.tin Peverrx Grade peter P/N:SEaao-t60D08NC4 inverter Corn stow Grade Pm0Xtgn and Ceeumpt on Mee P;ot SEnoo0l-U50005NM ter cex,mpton metenr4 current tuwemns 0xxrd be wiped eaparar*SEACTC'50-200N4-20 or SE ACT0!50.40014P-20 20 brats per Cox •dull po.n up to at oast 50C,122'P for pone(de-ruing Memnon reran M;copeptmmuobredoecom'Navdehun.eMLvotemperaesre-dnanrq-nob•nob& How to Enable Consumption Monitoring By simply wiring current transformers through the invertNC existing AC conduits and connecting them to the service panel,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills Single phase inverter vend . HD-wave technology and built-in RGM and Service Panelconsumption monitoring Grid Cr Lt N ShietdtlG050 oble A Le esimmorammue 10. l - L J AC Canduit O�Ieip..nobpa.Fc ma niguu n..e.fl,Ne E the Stlesde.inne,wmos20° SONREDGF are.sseveawnbaved nsees rantsdatdpaiadnetnntrc M1 Rolle lY7V o treeimerlts rr.ray.d herein.er.d.r..sa olr reg rrerhea.rwap.e.01rs122d+01,e000NMa 4Ljar to clung...roaz -10 Power Optimizer o For North America P370 / P400 / P401 / P485 / P505 m 70 i YEAR 1 0 WARRANTY E ' ill ,1 , , t , . , .; N m 70 PV power optimization at the module-level / Specifically designed to work with SolarEdge I Fast installation with a single bolt inverters / Next generation maintenance with module- / Up to 25% more energy level monitoring I Superior efficiency(99.5%) I Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid / Mitigates all types of module mismatch losses, Shutdown System (PVRSS) from manufacturing tolerance to partial shading I Module-level voltage shutdown for installer and firefighter safety I Flexible system design for maximum space utilization solaredge.com solar - se :' Power Optimizer For North America P370 / P400 / P401 / P485 / P505 Optimizer model . P370 P400 P401 P485 P505 (typical module compatibility) (for higher-power 60 (for 72&96- (for high power 60 (for high-voltage (for higher i and 72-cell modules) cell modules) and 72 cell modules) modules) current modules) INPUT Rated Input DC Powere 370 400 485 505 W Absolute Maximum Input Voltage 60 80 (Slot at lowest temperature) 60 1250 830 Vdc MPPT Operating Range 8-60 8-80 8-60 125-105 125-83 Vdc Maximum Short Circuit Current(Ix) 11 10.1 11.75 11 14 Adc Maximum Efficiency 995 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per power Optimizer 1 a 0: Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014,2017&2020 NEC 2014,2017&2020 NEC 2014,2017&2020 EMC FCC Part 15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(dass II safety),U.1741 Material UL94 V-0,UV Resistant RoHS lbs INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(W x L x H) 129x153 x 27.5/5.1x6 129x153x33.5/ 129x153x295/5.1x6 129x153x335/5.1 129x162x59/ mm x 1.1 5.1x6x1.3 x 1.16 x6x1.3 5.1x6.4a2.3 /in Weight(including cables) 655/1.4 750/1.7 655/1.4 845/1.9 1064/2.3 gr/lb Input Connector MC40 Single or dual MC4014 MC4a Input Wire Length 0.16/052,0.9/2.95H7 0.16/052 I 0.16/0.52,0.9/2.994 0.16/052 0.16/0.52 m/ft Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 12/3.9 m/ft Operating Temperature Range, -40to+85/-40to+185 'C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % (1)Rated power of the module at STC wit not exceed the optirmizer'Raed Input DC Power'.Modules with up to+5%power tolerance are allowed (2)NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SdaEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM.In the case of an odd number of PV modules in one siring,instating one P485 dual version power optimizer corrected to one PV module When connecting a single module seal the unused input connectors with the supplied pair of seals (5)For ambient temperature above+85'C/+185'F power de-rating is applied Beier to flower Optimizers Terrprxature De-Rating Yachted Note for more details PV System Design Using a SolarEdge Single Phase Three Phase for Three Phase for Inverter' HD-Wave Single phase 208V grid 277/480V grid Minimum String Length P370,P400,P401 c 10 18 (Power Optimizers) P485,P505 6 8 14 Maximum String Length(Fbwer Optimizers) 25 25 50 Maximum Nominal Power per String 57004(6000 with 52500 6000,1 127500'1 W SE7600-US-SEt1400-US) Parallel Strings of Different Lengths or Orientations Yes ' (6) For detailed string sizing information refer to httplAwow.solaedge.com/sites/default/lites/string_sizingita.pdf (7)It is not allowed to mix P485/P505 with P370/P400/P401 in one string (8) If the inverters rated AC power s maximum nominal power per string,then the maximum power per string will be able to reach up to the inserters maximum input DC power.Refer to:https://www solaredge. corn/sites/default/files/se-power-optimizer-single-strirg-design-application-notapdf (9) For 208V grid:it is allowed to instal up to 7200W per string when the maximum power difference between each string is 1,000W (10)For 277/480V grid:it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,0305V c SoarEdge Technologies Ltd All rights reserved SOLAREDGE,the SolrEdge logo,OPTIMIZED BY Sow uerro(ate trademarks or registered trademarks of SolarEdge Technologies, C UB Ro H$► Inc,All other trademarks mentioned herein are trademarks of their respective owners Date:04/2021 DS-000044-2.0-NA.Subject to charge w,thout notice. Intertek IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes.Each size supports specific design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match ,oLar Is Not Aisr=ys Surtrer; Over their lifetime,solar panels experience countless - extreme weather events,Not just the worst storms In years, . - .'` , s. iii_ but the worst storms In 40 years.High winds capable of _ _ —-----.- --li ripping panels from a roof,and snowfalls weighing - enough to buckle a panel frame. ,` _'--.ti - - s � ,.................k ,..............., .................___,. XR Rails are the structural backbone preventing r - - •---_, these results.They resist uplift,protect - - XRIO XR100 XR1000 against buckling and safely and efficiently ` sets a steaa.mw-prosy mounting XR100 a the ytmate residential XR1000 to a lxavmeemetn among transfer loads into the budding structure -:„,4- "--—o red designed lot repone wen light o mounting rail.It supports a range of solar mounting rails Its boa to bands Their superior spanning capability _ < nout no s .II chie achieves spans tip*s lees ndno vend a snow condemns.while an e also extreme debates and ions up to 12 ,+; whet,wh remonnIng!plot and economical un makzeng spans up to 10 WM feet for nAmtMlG al apphcat tins requires fewer roof attachments, } reducklg the number of roof _ t Y • s'spanning capability t • 10 spanning cepeawry • 12 epennngrapabkty penetrations and the amount /_ ♦ '` • Clear A black anodized lintsh •clear Heavy black oad caaanodt rid crash Cvtreme leae annfload >ddcar/at i sn h of installation time. , ., - • Internal apices avallesle • Internal splices available • Internal spares available p Rail Selection -r - The table below was prepared in compliance with applicable engineering codes end standards.•Values are I v. based on the following criteria:ASCE 7.16,Gable Roof Flush Mount,Root Zones 1&2e.Exposure B.Roof �,�`' Slope of 8 to 20 degrees and Mean Building Height of 30 ft Visit IronRldge com for detailed certification letters. „i " g s wya iPSq fii.o lGlf+H1` .44: I a ` Force-Stabilizing Curve 41 ? , Stowe roofs generate tooth van cal and dean 120 3'„ `„•e, Iorce.on mounting rails which can cause them I -, , to bend and Iwat.The curved shape of XR Rails None is specially designed to increase strength m both ��~140 %RYO XRt00 XflY000 directions while resisting the twists-Q.This unique i T 1, ` lealu,e enautee greatex security during estrange if� . weather end a btryar system tiletvrw. i____.. - _._.�.._. .._ .. , i 120 [ H:. r j ifX 1 00 Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 1 90 --- _ _ __.... _._....__....,..__ I 3- XR Rags are IronRrdgo el1M All XR Rails are made of 6000-sofas 40 t""' copatib Roth le a range of tilt lay in alumum with an then protected w an I i leo l m i f a FlasnF.a and - ..,. .. ..._...___..vz oP[gns br Ilan ere0rietl finrsn.Arad z rig prevenb surface i--- p... yr other pitched roof mot mount rq anti cnpctuml corms on pin Ic also provairg i S0 I 160 i,: i' . '. - attachments. applications. j 1 a more attractive appearance. " - C_ 120 180 "iNfwmlNxtti +.r..,,t!!.. � c rev:n?hale/axm'eaan§ties.Vila ntlanwd iJiinte>:nt,«n ern ra xnw.ral rKyr,yrHsrxxe. ` ~- U a:l0 ,-.xtputee,IM-M;:,€>ta'w.urrd'v tr'a--twit..u.cr.•m:r n` 0. cl -f Li ti,•rn+r�rtW-a:tro-n Ycrs„�,t.2t: /�