Loading...
Schumacher& AB ABV A/C AD ADD'L ADJ AFF AHU ALUM AP ARCH BD BLDG BLKG BLW B.O. CAB CJ CL CLG CLO CLR CMU CU CO COL CONC CONSTR CONT CONTR CTR D DBL DIA DIM DN DR DS DTL DW DWG DWR EA EF EL ELEC ELEV EP EQ EW EXP EXST/EX EXT F.F. FIN FLR FND F.O. FT FTG FURR G GA GALV GND GPM GR GWB H HB HD HDW HDWD HT HWH IRC IN ID INCL INSUL INT J JT L LBS MAS MATL MAX MDF MECH MFR MIN M.O. MTL N N/A NIC NO NOM NTS O.C. OD OVHD PNT/PTD PL PLUM PLYWD PR PSD PSI P.T. R RAD REF REINF REQ'D REV RM R.O. S SCHED SD SECT SF SHT SIM SLVG SPEC SQ STD STL STRUC T TBD TEL THK THRESH T.O. TYP UNF UNO UL VAN V.B. VTR W W. WC WD W/D WDW W/O WP AND ANCHOR BOLT ABOVE AIR CONDITIONING AREA DRAIN ADDITIONAL ADJUSTABLE ABOVE FINISED FLOOR AIR HANDLING UNIT ALUMINUM ACCESS PANEL ARCHITECTURAL BOARD BUILDING BLOCKING BELOW BOTTOM OF CABINET CONTROL JOINT CENTER LINE CEILING CLOSET CLEAR CONCRETE MASONRY UNIT CONDENSING UNIT CARBON MONOXIDE DETECTOR COLUMN CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CENTER DEEP DOUBLE DIAMETER DIMENSION DOWN DOOR DOWN SPOUT DETAIL DISHWASHER DRAWING DRAWER EACH EXHAUST FAN ELEVATION ELECTRIC/ELECTRICAL ELEVATOR ELECTRIC PANEL EQUAL EACH WAY EXPANSION EXISTING EXTERIOR FINISHED FLOOR FINISH FLOOR FOUNDATION FACE OF FEET FOOTING FURRING GAS GAUGE GALVANIZED GROUND GALLONS PER MINUTE GRADE GYPSUM WALL BOARD HIGH HOSE BIBB HEAD HARDWARE HARDWOOD HEIGHT HOT WATER HEATER INTERNATIONAL RESIDENTIAL CODE INCHES INSIDE DIAMETER INCLUDED/INCLUDING INSULATION INTERIOR JACK JOINT LENGTH POUNDS MASONRY MATERIAL MAXIMUM MEDIUM DENSITY FIBERBOARD MECHANICAL MANUFACTURER MINIMUM MASONRY OPENING METAL NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD PAINT / PAINTED PLATE PLUMBING PLYWOOD PAIR POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED RISER RADIUS REFRIGERATOR REINFORCED REQUIRED REVISION ROOM ROUGH OPENING SOUTH SCHEDULE SMOKE DETECTOR SECTION SQUARE FEET SHEET SIMILAR SALVAGE SPECIFICATION SQUARE STANDARD STEEL STRUCTURE TREAD TO BE DETERMINED TELEPHONE THICK THRESHOLD TOP OF TYPICAL UNFINISHED UNLESS NOTED OTHERWISE UNDERWRITERS LABORATORIES VANITY VAPOR BARRIER VENT THROUGH ROOF WIDE WITH WATER CLOSET WOOD WASHER / DRYER WINDOW WITHOUT WATERPROOF OVERALL DIMENSION - OUTSIDE FACE OF STUDS EXTERIOR WALL LOCATIONOUTSIDE FACE OF STUDS ..WINDOW/DOOR CENTERLINES. 5 1/2" INTERIOR PARTITION LOCATIONS 5 1/2" AND WALL THICKNESSES 3 1/2" TO EACH FACE OF STUD 5 1/2" APPROXIMATE DIMENSION ± 7' - 11" FIXED DIMENSION 8' - 8" DOOR NUMBER PER SCHEDULE DOOR WIDTH DOOR TAGWINDOW TAG WINDOW TYPE PER SCHEDULE ROOM NUMBER PER SCHEDULE ROOM TAG ROOM AREA 1t101 36" Room name 101150 SF CONCRETEEARTHGRAVELRIGID INSULATION BOARD BATT INSULATION LOOSE FILL INSULATION LOOSE FILL INSULATION PLYWOODWOODMETAL ROOFASPHALT SHINGLES WOOD FLOORING KEYNOTE KEYNOTE NUMBER, REFER TO SCHEDULE ALIGN FINISHED SURFACES SECTION MARK DRAWING NUMBER SHEET NUMBER STORY ELEVATION 1ALIGN 1 A101 NameElevation Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS As indicated 5/2/2022 10:26:41 AMCOVER SHEET 012 EAP G001Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILDA B B R E V I A T I O N S S C O P E O F W O R KD R A W I N G S T A N D A R D S D R A W I N G I N D E X Sheet No.Sheet Name CONTRACTOR REVIEW (xx/xx/xxxx)G001 COVER SHEET Z001 SITE AND ZONING A000 EXISTING / DEMO PLAN A001 EXISTING / DEMO PLANS A100 FLOOR PLAN A101 SECOND FLOOR PLAN A200 BUILDING ELEVATION A201 BUILDING ELEVATION A300 BUILDING SECTIONS A301 BUILDING SECTIONS A400 ENLARGED PLANS A500 DETAILS A600 SCHEDULES A601 SCHEDULES S100 STRUCTURAL NOTES S101 ROOF FRAMING PLAN S102 STRUCTURAL DRAWINGS S103 STRUCTURAL DRAWINGS E100 ELECTRICAL PLAN E101 ELECTRICAL PLAN C O D E S 5B (EXISTING) 5B (PROPOSED) CONSTRUCTION TYPE: C O D E A N A L Y S I S P R O J E C T T E A M OWNER NAMES Jim Schumacher & Lorraine Mangione 21 West Parsons Lane Northampton Ma, 01060 Construct Associates Designer 36 Service Center Rd. Northampton Ma 01060 (E): ericparham.a@gmail.com (P): 413-461-8490 CONTACT: Eric Parham BUILDER Construct Associates 36 Service Center Rd. Northampton Ma 01060 (E): walker@constructassociates.com (P): 413-584-1224 CONTACT: Robert Walker STRUCTURAL ENGINEER STRUCTURAL ENGINEER ENGINEER ADDRESS P R O J E C T L O C A T I O N SITE ADDRESS: LOT: BLOCK: TAX ID: ZONE: 21 West Parson Lane LOT GOES HERE BLOCK GOES HERE ID GOES HERE ZONE GOES HERE 2018 INTERNATIONAL RESIDENTIAL CODE2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL PLUMBING CODE 2011 NATIONAL ELECTRICAL CODE 2018 ENERGY CONSERVATION CODE D I M E N S I O N M E T H O D C O M M O N M A T E R I A L S D R A W I N G S Y M B O L S Re-build of existing sunroom. Repair of storm damage to existing structure 1COVER 1 Date 1 Revision 1 1. 2. ALL DIMENSIONS ARE FROM FACE OF STUD OF NEW WALLS AND FINISHED SURFACE OF EXISTING WALLS UNLESS OTHERWISE NOTED. TYPICAL INTERIOR PARTITION IS 2x4 STUD @ 16" O.C. WITH ONE LAYER OF 1/2" GYP BOARD ON EACH SIDE, EXCEPT WHERE NOTED ON PLANS. USE 2x6 STUDS AT PLUMBING WALLS. NEW CONSTRUCTION EXISTING TO REMAIN A2012 A200 2 A2011 1 1 A300 2 A300 2' - 4"2' - 4" AVAILABLE SPACE FOR BOOK SHELVES 3 1/2"3 1/2"11 3/4"5' - 0"2' - 11 1/8"2' - 6"3 5/8"11 3/4"5' - 0"6"5' - 0"12' - 0"3 1/2" 2' - 5 1/8"5' - 0"6"5' - 0"2' - 5 1/8" 3 1/2"15' - 11 1/4" 6' - 0" EXISTING SLIDING DOOR 2 3/4"Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS As indicated 5/2/2022 10:26:43 AMFLOOR PLAN 012 EAP A100Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILDFLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES 1 LANDING TO REMAIN NEW STAIR/RAILING 1/2" = 1'-0"1PROPOSED FIRST FLOOR PLAN 1 Date 1 Revision 1 TOFW1' - 6" (E) 1ST FL TOP9' - 6" FOOTING-4' - 0" 1 A300 1 GRADE 0' - 0" 6" / 1 ' - 0 " 6" / 1'- 0" BC AA VIF ROOF PITCH TO MATCH WINDOWS B & C Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"5/2/2022 10:26:46 AMBUILDING ELEVATION 012 EAP A200Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILDELEVATION GENERAL NOTES ELEVATION KEYNOTES 1 EXISTING FLOOR SYSTEM TO REMAIN 1/4" = 1'-0"2South Elevation 1 Date 1 Revision 1 TOFW 1' - 6" (E) 1ST FL TOP9' - 6" 2 FOOTING-4' - 0" 2 A300 GRADE0' - 0" AA TOFW 1' - 6" (E) 1ST FL TOP9' - 6" 2 FOOTING -4' - 0" 2 A300 GRADE0' - 0" A Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"5/2/2022 10:26:48 AMBUILDING ELEVATION 012 EAP A201Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILDELEVATION GENERAL NOTES ELEVATION KEYNOTES 1 EXISTING FLOOR SYSTEM TO REMAIN 1/4" = 1'-0"1West Elevation 1/4" = 1'-0"2East Elevation 1 Date 1 Revision 1 TOFW 1' - 6" (E) 1ST FL TOP9' - 6" 2 A300 3' - 4"6"4' - 0"2' - 8"TOFW 1' - 6" (E) 1ST FL TOP9' - 6" 1 A300 GRADE0' - 0"4' - 0"2' - 8"1' - 1 3/8"32" SILL HEIGHT AFF. DBL. 2X10 HEADER TYP. EXISTING FLOOR SYSTEM TO REMAIN NEW 3/4" T&G SUBFLOOR Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/4" = 1'-0"5/2/2022 10:26:50 AMBUILDING SECTIONS 012 Author A300Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILD 1/4" = 1'-0"1 SECTION A 1/4" = 1'-0"2SECTION B 1 Date 1 Revision 1 FINISH FLOOR WINDOW A 2' - 8"4' - 0"6"WINDOW B 10"2' - 6"Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/2" = 1'-0"5/2/2022 10:26:53 AMSCHEDULES 012 Author A601Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILDMARKQTYTYPEMANUFACTURERMODELWIDTHHEIGHTSHGC U-FACTOR TEM PER ED COMMEN TS Rough Height Rough Width A5Marvin Windows and DoorsELGL606060"48"0.32 0.28 4' - 0 1/2"5' - 1" B1Marvin Windows and DoorsMDGTRAP60"40"LEFT 3' - 4 3/4"5' - 1 1/2" C1Marvin Windows and DoorsMDGTRAP60"40"Right 3' - 4 3/4"5' - 1 1/2" W I N D O W S C H E D U L E 1. 2. 3. 4. 5. 6. 7. PERFORM WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NEC) AND CODES AND REGULATIONS OF JURISDICTIONAL AUTHORITIES. DO NOT CONSTRUE ANYTHING ON THESE PLANS AS CONFLICTING WITH ANY LOCAL OR STATE LAW, REGULATION OR ORDINANCE GOVERNING THE WORK. WHERE ANY PORTION OF THE WORK IS NOT INSTALLED IN ACCORDANCE WITH APPLICABLE LAWS, ORDINANCES, REGULATIONS AND CODES, MAKE CHANGES REQUIRED BY THE ENFORCING AUTHORITIES IN A MANNER APPROVED BY THE OWNER WITHOUT ADDITIONAL COST TO THE OWNER. EQUIPMENT IS NOT TO BE INSTALLED IN CONFLICT WITH THE NEC. RESOLVE ANY CONFLICTS BEFORE INSTALLATION AT NO ADDITIONAL COST TO THE OWNER. ELECTRICAL EQUIPMENT TO BE NEW, UNDAMAGED, LISTED BY UNDERWRITERS LABORATORY, INC. AND BEAR THE 'UL' LABEL. INSTALL EQUIPMENT IN STRICT ACCORD WITH MANUFACTURERS' RECOMMENDATIONS UNLESS THE CONTRACT DOCUMENTS REQUIRE A HIGHER QUALITY INSTALLATION THAN THAT RECOMMENDED BY THE MANUFACTURER. TEST ALL SYSTEMS, DEVICES AND RELATED EQUIPMENT ON-SITE WITH EQUIPMENT IN PLACE AS WORK IS COMPLETED. REPLACE ANYTHING FOUND TO BE DEFECTIVE AND RETEST UNTIL SATISFACTORY AT NO ADDITIONAL COST TO THE OWNER. SUPPORT AND SECURE ALL LIGHTS IN ACCORDANCE WITH NEC. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND ARE FOR CIRCUIT ALLOCATION ONLY. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS OF FIXTURES. THE ELECTRICAL INSTALLATION SHALL CONFORM TO APPLICABLE BUILDING CODES. A PERMIT SHALL BE SECURED PRIOR TO COMMENCEMENT OF ANY WORK. ALL CEILING AND WALL MOUNTED LIGHTS, MINIMUM OF 75% OF ALL LAMPS IN ELECTRICAL FIXTURES, ARE REQUIRED TO BE HIGH EFFICIENCY. BUILDER SHALL USE 60-WATT EQUIVALENT CFL WITH THE FOLLOWING SPECIFICATIONS: 14 WATTS 800 LUMENS 240 V RECEPTACLE DUPLEX RECEPTACLE GFI RECEPTACLE GFI RECEPTACLE MOUNT AT 36" A.F.F. WATERPROOF RECEPTACLE RECESSED CAN LIGHTS PENDANT LIGHT GFI RECEPTACLE MOUNT AT 42" A.F.F. RECESSED STRIP LIGHT SURFACE MOUNTED STRIP LIGHT UNDER CABINET LIGHT SURFACE MOUNTED LIGHT WALL LIGHT CARBON MONOXIDE DETECTOR SMOKE DETECTOREQEQEQEXTERIOR SPOT 4' LED WAFER TPY. Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS As indicated 5/2/2022 10:26:56 AMELECTRICAL PLAN 012 Author E100Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILDELECTRICAL NOTES ELECTRICAL SYMBOLS 1/2" = 1'-0"1FIRST FLOOR ELECTRICAL LAYOUT 1 Date 1 Revision 1 1 A300 2 A300 STRUCTURAL RIDGE 2X 1.9E LVL 11 7/8 X 1 3/4 2X8 KD @ 16" OC TYP.2X8 KD @ 16" OC TYP. 3 1/2" X 3 1/2" KD POST BELOW 3 1/2" X 3 1/2" KD POST BELOW2X4 EAVE OVERHANG TPY.Scale No. 6 Project number:PLOT DATE:Construct Associates 36 Service Center Rd. Northampton, Ma 01060 413-584-1224 constructassociates.com STATUS: REVISION LOG REV #DATE DESCRIPTION DRAWN BY: SHEET NO. SHEET NAME CLIENT NAMEPROJECT ADDRESSBUILDER NAMEBUILDER CONTACTDPS PERMIT NUMBER: ORIGINAL DRAWING SIZE IS 24" X 18" DO NOT SCALE DRAWINGS FOR MEASUREMENTS 1/2" = 1'-0"5/2/2022 10:26:58 AMROOF FRAMING PLAN 012 EAP S101Schumacher21 West Parsons LaneNorthampton Ma, 01060SDSUNROOM RE-BUILD 1/2" = 1'-0"1Roof Framing 1 Date 1 Revision 1