Loading...
35-038 (10) BP-2022-0561 190 WEST FARMS RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 35-038-001 CITY(W NCiRTHAMPTON Permit: Solid Fuel Appliance PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2022-0561 PERMISSIONIS HEREBY GRANTED TO: Project# WOOD STOVE Contractor: License: Est. Cost: DOUGLAS L'ABBEE 99401 Const.Class: Exp.Date:01/06/2024 Use Group: Owner: MATH IESEN MARISA Lot Size (sq.ft.) Zoning: WSP Applicant: THE FIRE PLACE Applicant Address Phone: Insurance: PO BOX 606 (413)397-3463 014005033011 16 WHATLEY, MA 01093 ISSUED ON:05/19/2022 TO PERFORM THE FOLLOWING WORK: WOOD STOVE INSERT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House # Foundation: Final: Final: Final: Rough Frame: Gas: Fire Department Driveway Final: Fireplace/Chimney: Rough: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: X►___ Fees Paid: $40.00 212 Main Street. Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner City of Northampton � � rECI` Massachusetts 4- e ;c ��a DEPARTMENT OF BUILDING INSPECTIO S t ° 212 Main Street • Municipal Buildinhq MAY 1 8 �' Northampton, MA 01060 20 s�. ;ejr�` (/ - • DSPT.OF BUILDING INSPECTIONS j _ NORTHAMPTON,MA 01060 APPLICATION FOR SOLID FUEL APPLIANCE INSTALLATION Property Information Owners Name: 127.rri5(.._ /Y) Address: /90 //5'7 �rrAs / � F/orestcc 0/4 (No.) (Street Address) Phone: .5.717 t/V '-3 S'Y Cell: Email: Owners Signature: /L/ Date: ;" Contractor's Information (If Applicable) Name:(-7D ooy/q., A2h2ct - T c .ecc Phone: V/3 3 77 3 Construction Supervisor's License #: y9V0/ Expiration: /-C- 2 9 Home Impr. Contractor License #: / '77 Expiration: //-/tea Stove Information Type of Fuel (check all that apply): Wood X Pellet Coal Location: F/s f! ac C Freestanding Insert Manufacturer: Lcp/ Model: L vcrgrccr 1%lserF o--A. (Al -,ez 5:5 4r r- /11/6 Zu -----------FOR BUILDING DEPARTMENT USE ONLY---------------_---------- Permit# 64- 6/iJ Date Applied: Total all Fees: $ Building Official: f uia Date Issued: 5-t -202 2 Signature of Building Official: (P�p��i • 6 Fire • lace Insert Installation (for qualified installers only) Installation Options Features • Masonry Fireplace Insert • Single Operating Control • Zero-Clearance (Metal) Fireplace Insert • Steel Plate Construction (1/4" & 3/16") • Heavy Duty Refractory Firebrick • Optional High-Tech Blower Heating Specifications Approximate Maximum Heating Capacity (in square feet)* up to 2,000 (185 square meters) EPA Tested Cord Wood BTUs per Hour** 12,772 to 70,720 Maximum Burn Time Up to 10 Hours * Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected by the quality and moisture level of the fuel. ** EPA tests to determine BTU output are achieved with a single load of wood at each burn rate. At home, you are likely to add more wood to your stove to maintain your desired comfort level. By the simple process of loading your stove with additional wood, you could achieve up to a 20% higher heat output than established during EPA testing. This model was tested for efficiency using method B415.1-10 and was determined to have a weighted average Higher Heating Value (HHV) Overall Heating Efficiency (OHE)of 77.1%. Overall efficiency of the heater may be lower if the heater is operated without a heat exchange blower or with the installed heat exchange blower turned off. Dimensions 6" (153mm) Dia. I \ ; 26„ Small - 30-1/2" - P " " (661mm) (775mm) . \23-1/2" 1 - , :, _� (597mm)� Large 34" 9-3/8" (�, �\� \ (239mm)� 5-7/8" (864mm) � �"" 1 (153mm) ;\ I 23„ 4 s (585mm) a , „--- ', ',,,T.\„k.<<..--:,. . .---„, itii ,/ ._....., Small - 42" r (1067mm) O----, 15-1/8' (385mm) Large -44" / (1118mm) \f 19-3/8" (493mm) Emissions This heater meets the 2020 U.S. EPA's cord wood emission limits for wood heaters. Tested to EPA Alt-125, ASTM E3053-17, ASTM 2515-11, CSA B415.1-10 this heater has been shown to deliver heat at rates FM ranging from 12,772 to 70,720 BTU/hr and an emission value of 1.52g/h. Report No. 0028WS119E a,) ©Travis Industries 5/11/2022 - 1560 Evergreen Insert Fire • lace Insert Installation (for qualified installers only) 7 SAFETY NOTICE: Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage,bodily injury,or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Planning the Installation OWe suggest that you have an authorized Travis Industries dealer install your fireplace insert. If you install the fireplace insert yourself, your authorized dealer should review your installation plans. OCheck with local building officials for any permits required for installation of this fireplace insert and notify your insurance company before proceeding with installation. Preparation for Installation • Check for damage to the exterior of the fireplace insert(dents should be reported, scratches can be fixed by applying touch up paint). • Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place). 8 The fireplace insert can be lightened by removing the firebricks (pg 31)- replace before operation. Installation Considerations Installation Type Considerations Insert with Positive Flue(Full Reline) • Utilizes existing masonry or zero clearance fireplace (Page 14) • Provides best draft •Easiest to clean Insert with Direct Connect Flue •Masonry fireplace only •Provides good draft (Page 15) • Requires fireplace block-off plate Packing List • Wood Moisture Meter • Bypass tool • Gloves Additional Accessories Needed for Installation • Surround Panels (see page 16) ©Travis Industries 5/13/2022 - 1560 Evergreen Insert 8 Fire • lace Insert Installation (for qualified installers only) Fireplace Requirements Minimum fireplace size requirements are shown below. \ Minimum Fireplace Size (a) Height(front) 23-1/4" (591mm) (b) Height(rear) 23-1/4" Co. (591mm) ,_ 0St'b/e,l� (c)Width (front) 26-1/4 1� � auto/ - (667mm) 23-3/4 (603mm) �o�,co�b SGb�e / 15-1/4 (388mm) O FaQ�9 (d)Width (rear) (f) Hearth Depth 20-1/4" 8 (e) Depth* (Includes insert depth on (515mm)US \ hearth plus required hearth 22-1/4" 0 ! extension) (566mm)CA 35-5/8" 0 (905mm)US N (g) Hearth Width °�.0 39-5/8" o�bosf/b/°y (100 42m)CA O each (h) Facing Width (1067mm) © (i) Facing Height 36-3/4" �/ (above base of insert) (934mm) (j) Mantel Height 43" (above base of insert) (1093mm) Fireplace Altered Tag Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other suitable method). You may wish to place it in a location \ where it will be covered by the surround panels. \ ©Travis Industries 5/11/2022- 1560 Evergreen Insert Fire • lace Insert Installation (for qualified installers only) 9 Insert Placement Requirements • The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the insert. • Insert and hearth must be installed on a level, secure floor • The minimum clearances, facing, and hearth requirements listed below must be met. Follow the clearances for the type of fireplace being used—(masonry or zero-clearance-metal). Minimum Clearances (k)Sidewall 18" (458mm) Co (I)Side Facing 8" -645. (204mm) °67bo,,,t. Ma�,e� (m)Top Facing (934mm) Side Tdo Wall R sac;°9 (n)Mantel 43" `e•09 Max. Depth 12"(305mm) (1093mm) /--1 (o)Mantel Leg 8" 0 \ / Max. Depth 9-1/2"(242mm) (204mm) n (p)Front Hearth(does not include 16" insert extension"x" (407mm)(US) / 18„ i0 _ (458mm)(Canada) 0 (q)Side Hearth 6" O / � (153mm)(US) 8" (204mm)(Canada) o,,'c% •' (r)Front of Insert 36" 0 tieejr6°Stab/e 'f© (915mm) Q (x)Extension onto Hearth* 4-1/4"* (108mm*) *This dimension is for a panel with no trim. If using the optional trim the insert will extend 5-1/2"(134mm)onto the hearth. Masonry Fireplace - Hearth Extension Requirements • Must extend 16" (USA)or 18" (Canada) in front of the insert and 6" (USA)or 8" (Canada) on both sides From chart above USA- min. 20-1/4" (515mm)deep by 35-5/8" (905mm)wide (x) + (p) = Min. hearth required from Canada- min. 22-1/4" (566mm)deep by 39-5/8" (1007mm) front of fireplace opening wide • Masonry hearth extensions must be non-combustible and at least .018"thick (26 gauge). ©Travis Industries 5/11/2022- 1560 Evergreen Insert 10 Fire • lace Insert Installation (for qualified installers only) Masonry Fireplace Requirements CANADA ONLY: The fireplace insert must be installed with a continuous chimney liner of 6"diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirement of Can/ULC S635, Standard Lining Systems for Existing Masonry or Factory- Built Chimney &Vents, or CAN/ULC S640, Standard for Lining Systems for New Masonry Chimneys. • Chimney must have a clay tile liner or a stainless steel liner(positive connection). • Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired prior to the installation of the insert. • Chimney height: 15' (4.5M) minimum; 33' (10M) maximum. • The fireplace insert must be placed on a masonry hearth built to UBC standards. • Do not remove bricks or mortar from the existing fireplace. EXCEPTION: Masonry or steel, including the damper plate, may be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner, provided that the removal will not weaken the structure of the fireplace and chimney, and will not reduce protection for combustible materials to less than that required by the National Building Code. • Remove or lock the fireplace damper in the open position. • Permanently seal any opening between the masonry of the fireplace and the facing masonry. Zero-Clearance (Metal) Fireplace - Hearth Requirements FLUSH INSTALLATIONS (insert raised less than 5" (127mm) above a combustible floor): The hearth must provide an R-value (thermal resistance)of 1.19 or greater. In the USA the hearth must extend a minimum of 16" (407mm) in front of the fireplace insert. In CANADA the hearth must extend a minimum of 18" (458mm) in front of the fireplace insert. The hearth must extend 6" (153mm) (US)or 8" (204mm) (Can)from both sides of the insert. RAISED INSTALLATIONS (insert raised a minimum 5" (127mm) above the floor): If the base of the insert is a minimum of 5" (127mm) above the combustible floor(carpet, wood, etc.)the hearth must extend 16"407mm (USA)/ 18"458mm (CANADA) in front of the insert. The hearth must extend 6" (153mm) (US) or 8" (204mm) (Can)from both sides of the insert. The hearth must be non-combustible (cement board, tile, etc.) but does not need to meet an R-value (thermal resistance). FLUSH INSTALLATIONS RAISED INSTALLATIONS (See details above) (See details above) Hearth R value R=1.19 or greater Non-Combustible Hearth (Tile,Cement Board,etc.) No R value required USA Min.2"(51 mm) Ember protection only CANADA Min.1"(26mm) 6" o .o 5. ! Min.5" Combustible (127mm) • Flooring USA Min.16"(407mm) S , CANADA Min. 18"(458mm) Combustible USA Min. 16"(407mm) Flooring CANADA Min. 18"(458mm) ©Travis Industries 5/11/2022 - 1560 Evergreen Insert Fire • lace Insert Installation (for qualified installers only) 11 Mantel Requirements • See minimum mantel clearances below. Max. 12"(305mm) Maximum Mantel Depth ct,F F �ry ���� e eV N r N ti n,e O N �0 �� n0 ^0 --Max. 1"(26mm) ` ` ` ��L ti c 4> co ti 44" ������������ Min.43" (1093mm) 43"(1093mm) Mantel Height 42" ,\'••■■■■■■■ Min. 39" 1111111111116'41111111111111ME (990mm) Ataove Base 41" of Insert 40" ■•■■■•',••■■ 39"(990mm) 111111111 •111111E'E,NI Base of Insert , ©Travis Industries 5/11/2022- 1560 Evergreen Insert 14 Fire Glace Insert Installation (for qualified installers only) Insert with Positive Connection REQUIRED IN CANADA. Sealing the Flue to the Insert MEI —EMI The flue connection is vitally important. To ensure proper draft, and to prevent smoke spillage - during re-loading, it is crucial for the flue to be no — 1 sealed with fireplace cement. If an adapter is n i ; 1 EN 0 used, both joints to the liner and the insert should r ia I 0 be sealed. Use a generous amount of fireplace IN-� 0 cement at every connection (where the flue (—"l■ I. - connects to the insert and at every joint). is mu I 0 In addition, we recommend using non- r—i mime 10 combustible fiberglass insulation to seal the 0 fireplace enclosure. By sealing the top and N EN 10 bottom of the chimney, and the surround panels, C I - No you will be ensuring outside air is not pulled into ■ iimi 10 the chimney. 0II - - ■ ow 10 I-1i MIMI ■ IIM IO r1I Nei iii isum 10 nr NI IN ■I-1/ , 10 II NI IO M NI I IN 0OON. ifi *oo _0- �o. �O irm ._ . O Flue Installation The flue(or INTEGRITYTM Super Stove Starter adapter)may Flue(flexible or rigid) be notched to �\� � INTEGRITY Venting Systems allow room for manufactures starter sections in 3 brackets and 6 self straight or angled configurations to - :101A the bypass rod. drilling screws are g g g included with the insert. suit your application. They arek � Use these components secured from inside the firebox, Th - to secure the flue making installation much easier. 1111' (and/or appliance Contact INTEGRITY Venting 4_ Systems for additional details: Top of Insert nadapter)to the insert. 4 a i integrityventingsystems.com eip '"TV ©Travis Industries 5/11/2022- 1560 Evergreen Insert