Loading...
18D-040 APPLICATION ON HOLD Commonwealth of Massachusetts City Of Northampton Date: 11-21-2019 See It permit# `gym o +i ED Estimated Job Cost: $ 6,000 NOV Per ►it Fee: $ /(� Plans Submitted: YES X NO 2 O 201�1an• Rev,ewed: YES NO pp.,. NO Business License# T"q 4 74i a•. .. s ice se# 13107 °1p6.0 S Business Information: Property • • r/Job Location Information: Name: CLAYTON BERUBE JR Name: PRIDE Street: 68 AMES AVE 3RD LEFT Street: 375 KING ST City/Town: CHICOPEE, MA City/Town: NORTHAMPTON Telephone: 860-394-9946 Telephone: 413-737-6992 Photo I.D. required/Copy of Photo I.D. attached: YES X NO Staff Initial J-1 M-1-unrestricted license J-2/M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail X Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. X over 10,000 sq. ft. Number of Stories: 1 Sheet metal work to be completed: New Work: X Renovation: HVAC Metal Watershed Roofing Kitchen Exhaust System X Metal Chimney/ Vents Air Balancing Provide detailed description of work to be done: INSTALL PREFACRICATED KITCHEN EXHAUST HOOD INCLUDING PREFABRICATED DUCTWORK AND FAN. (FIRE SUPPRESSION SYTEM TO BE DESIGN AND INSTALLED BY,ALLSTATE FIRE EQUIPMENT) Fees with Building Permit: $25.00 Residential, $50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential, $100.00 Commercial INSURANCE COVERAGE: I have a current Jiahility insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes❑ No If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy ❑ Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee dnpc not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waivPsthis requirement. Check One Only Owner ❑ Agent Signature of Owner or Owner's Agent By checking this box®,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progress incp ctions Date Comments Final incpPrtinn Date Cnmmerlts. Type of License: By ® Master Title ❑ Master-Restricted City/Town ❑Journeyperson Signature of Licensee Permit# ❑Journeyperson-Restricted 13107 License Number: Fee$ ❑ Check at www macc gnv/rfpl Inspector Signature of Permit Approval 1 , 1 - .....< cy, , Fold,Then Detach Along All Perforations . , • ,-. - ' . --- = ...''7S e"' 'it-r1-7.-.- ''. ,,:,...... ...4, .;,..;1 i.:;......1,!,:,:01,;,„1. ' ':::: ......,F PROFESSIONAL LICENSURE . .. , iLt-4:14.4. &:-I, -',.fr;.:74-4-":-'1':".'''.--:• 1151ifi41.Y1-';. . .,...... .,...,"."' '.. ' '-: ', :.:',,,..,;1':4:-.; ."-•..:4 4:Z.1. 1),tt(' J.4......-'4).-..:',..‘0...':.'jt.,-.42.i.si-41-''.' .---"'S,-4.,:. *-1-44t6r7,'11 - :. .-- ' 1 '''"r•T'3.'''-'977f`;W'''''";.-‘•3:-1Z7-":A...":--'1,,.7.'-',::;.':."34.,-!,,*,..t.t.'431:-.'iY-7b'' !'` ''...Y'. ,;,—. -4'" ;,.. l'.,,.... ,,- '..,--s-Yi.::%-:F,f34;:lryce,:-.--:-.f.:00T---;7'.' '-'- •=744',:li4." .*". '.".\'''' 1-= '-'..' ( ' ANIESAitp ;.-,:i-,-.--va,, i,,,.....R7...,4741,-. ,..., . ,. . . ' -.. , -2.- 3RD LEFT-t-=-Zi-i- .:4...; ...... Tf,;tCHICOPEE-': - ..,--„,:rvx-'-T..,, ,..,,,.... . ---,--..:.•--, 1j, )7 .- -1-- ''' '-' 03/29t4W.,,f1,--NA7/' 204815 . ., - .. .,•:,,. . . :r!,',:.----.' --' ',...,:nor,nTinkrr,'...•rc - cc cti A t SSACTiusErrs DRIVER'S . . tICENSE . .,. _ .... . , , ., . 7881 0127120.22 03427i1S76 D 13 Mtn ii„: -,,t-:. -4.7---'5,,•5:......--,,f,:- 'p rRI.,2,6E Arc*JOHN JR .,. ,.., ,RD Ft.LEFT -- - z,7„,,,,,,,,,„,";--?.' ,4:'-'3... °f'EE.*4 13-243;4 4t1"-- wx hi -A‘T V,41.F Ix oarsuant km!value* 4. .,0:444. . 1'-6" 4'-0" R.O. 1'-6" I I 'in In a N. �, " RUBO 4 'it' �i �"I BKRYoTa,�.� co 5 zm EXISTING ,.,,,..__I___ ,,,._ CUPS WALK-IN 3 �s�� CAFE BAKERY BREWER FREEZER — Y-.� 1p„3•_b„ ESPRESSO I- -I 3,_O„ CREAMER CKN 1 SALES COUNTER SUGAR •: 70'506" r - HOOD INFORMATION - ✓ob#4078331 HOOD MAX. EXHAUST PLENUM HOOD CONFIG. TAG MODEL LENGTH COOKING APPLIANCE DESIGN TOTAL RISER(S) HOOD END TO NO. TEMP. DUTY CFM/ft EXH. CFM WIDTH LENG.HEIGHT DIA. CFM VEL. S.P. CONSTRUCTION END ROW 1 3650 5' 3' 450 Medium 160 840 4' 10' 840 1540 -0.588' 430 SS ALONE ALONE BD-2 Deg. Where Exposed HOOD INFORMATION FILTER(S) LIGHT<S) UTILITY CABINET(S) FIRE HOOD HOOD EFFICIENCY Q 7 WIRE FIRE SYSTEM ELECTRICAL SWITCHES SYSTEM HANGING NO. TAG TYPE QTY.HEIGHT LENGTH MICRONS QTY. TYPE GUARD LOCATION SIZE TYPE SIZE MODEL # QUANTITY PIPING WGHT See 1 CaptrAte Solo Filter 3 16' 16' 85/ Spec.Falter 2 L55 Series E26 NO NO 239 LBS FLOOD OPTIONS HOOD TAG OPTION SPECIFICATION: CAPTRATE GREASE-STOP.SOLO FILTER NO. WRAPPER CHANNEL - Front, Right THE CAPTRATE GREASE-STOP SOLO FILTER IS A SINGLE-STAGE FILTER FEATURING LEFT END STANDOFF<FIN/SLP) 1' Wide 36' Long Insulated A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. I RIGHT QUARTER END PANEL 26' Top Width, 0' Bottom Width, 26' High 430 SS FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD LEFT QUARTER END PANEL 26' Top Width, 0' Bottom Width, 26' High 430 SS 2-INCH DEEP HOOD CHANNEL(S). INSULATION FOR TOP OF HOOD UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TVO INSULATION FOR BACK OF HOOD COMPONENTS WHEN ASSEMBLED. GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. THE CAPTRATE GREASE-STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. 1' LAYER OF INSULATION FACTORY EFFICIENCY VS.PARTICLE DIAMETER PRESSURE DROP VS FLOW PLATE INSTALLED IN BACK STANDOFF. '''' MEETS 0 INCH REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES. a m 1' LAYER OF INSULATION r "° FACTORY INSTALLED IN 6 m ri r 1.00' END STANDOFF MEETS ` =a 0' REQUIREMENTS CLEARANCE o w TO COMBUSTIBLE SURFACES. .�i� i //////////Zi/////.- 6 1 .-j ,.. i t ono' AV,„ I PARTICLE DIAMETER„ (pm)TI FLOW'RATE(cfm) 36' � 11 CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH.. U.L. Listed L55 Series E26 •nopy NFPA #96 - I Light Fixture - High Temp A-senbly NSF 2 <® 0 INT. MECH. CODE (IMC) ® ® ULC-5649 34 7/8' - 28 1/8' FOR QUESTIONS, CALL THE: NORTHEAST SALES DIVISION 450 COTTAGE STREET SPRINGFIELD, WA 01104 5' 3'Nom./5' 3.00'0D PHONE: (888) 594-8390 FAX: (919) 227-5956 5'-4.00' Overall Length CAPTIVE-AIRE HOODS ARE BUILIT IN C❑MPLIANCE WITH PLAN VIEW — Hood #1 WI' 5' 3.00" LONG 3650BD-20 I , NFPA #96 - 2014 EDITION ETL LISTED TO UL-710 REQUIREMENTS IMC 2015 CUSTOMER APPROVAL TO MANUFACTURE, Approved as Noted ❑ Approved with NO Exception Taken ✓OBPride King Street Northampton � � q tel.). Ct, �� all rAN� _ __ LOCATION N❑RTHAMPT❑N, MA, 01060 Revise and Resubn G.6 B� 0 ���__ DATE 11/20/2019 ✓OB # 4078331 SIGNATUREi;NerteX ,. .— lJ�tii' /( 1 BRA/3'N BYTSH-37 Your Title Senior project mgr Date11-21 2019 — -- !/ ti v• - L55 SERIES E26 CANOPY LIGHT FIXTURE - HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL AND SHOCK RESISTANT GLOBE (L55 FIXTURE) 1' LAYER OF INSULATION FACTORY INSTALLED HOOD CORNER / ON TOP OF HOOD. MEETS 0 INCH yr-13 rnl I-ANGING_ANfil F REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE SURFACES STEEL D NUTS (HARDWARE BY INSTALLER) 36' SSTEELHEXD NUTS yr R 5 / aw wDxO STEEL UV IllEXHAUST RISER FLAT VASIER DID M■ _ U. .■■- lit-13 TM HUUD ABLE GRADE S MINIMUM LALL-THREAD - Vr-13 TP1 16' CAPTRATE SOLO I 1 STEEL 5 1' LAYER OF INFS�ILT ONIniCMgPlf MUT MIT STEEL NED „r GRADE 5 HOOD CORNER INSTALLED IN 3' INTERNAL STANDOFF. 14' NOM. a1wDTM)STEEL ANGLEv FLAT VAER Ax`c arnTFaw° ST MEETS 0 INCH REQUIREMENTS FOR u� °" m°' ■■ CLEARANCE TO COMBUSTIBLE SURFACES. O 11... IT IS THE RESPONSIBILITY ii V2.OADE ■■(TtE M)s*m / �I OF THE THEHITECT/OWARR TO S ENSURE THAT THE HOOD CLEARANCE y50' yr-I3 TP1 FROM LIMITED-COMBUSTIBLES`STTEEL HE%NUTSAND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH47,0' MAX ASSEMBLY INSTRUCTIONS LOCAL CODE REQUIREMENTS. HANGING ANGLE MUST BE SUPPORTED WITH 1/2' - 13 TPI GREASE DRAIN GRADE 5 (MINIMUM) ALL-THREAD. SANDWICH HANGING ANGLES AND CEILING ANCHOR POINTS WITH 1/2' GRADE 5 WITH REMOVABLE CUP (MINIMUM) STEEL FLAT WASHERS AND 1/2' - 13 TPI FIELD INSTALLED 71' GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE / DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING QUARTER END PANELS / ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4' OF EXPOSED THREADS BENEATH BOTTOM HEX NUT. TORQUE EQUIPMENT ALL HEX NUTS TO 57 FT-LBS. BY OTHERS 35' SECTION VIEW - MODEL 3650BD-2 HOOD - #1 CUSTOMER APPROVAL TO MANUFACTURE: Approved as Noted 0 Approved with NO Exception Taken JOBPride King Street Northampton Revise and Resubmit ..,--, C� (J� .s. ♦ 1 _ -I= _� LOCATION NORTHAMPTON, MA, 01060 SIGNATURE au�u� D E11/a I C InV I I�=_c DATE 11/20/2019 JOB , 4078331 Your TM. Dote �= Dg'C # 2 DRAWN BYTSH-37 EXHAUST FAN. EXH UST AN INFORMATION - Job#4078331 FAN DISCHARGE WEIGHT UNIT TAG FAN UNIT MODEL X CFM ESP. RPM H.P. B.H.P. 0 VOLT FLA VELOCITY (LBS.) SONES NCI. HIGH TO SEAL THE FAN TO THE TEMPGASKET IS USED I DU5OHFA 840 0.750 1259 0.500 0.2240 1 115 6.3 319 FPM 77 11.4 TRANSITION N PLATE. al" FAN OPTIONS FAN UNIT TAG OPTION (Qty. - Descr.) NO. TO DINER _HE TIDU PLATE, DED 1 - Grease Box WELDS ARE DYE TESTED. 1 1 - ECM Wiring Package - Manual or 0-10VDC Reference Speed Control (TELCO Motor), CCV Rotation IllAFAN ACCESSORIES - EXHAUST SUPPLY � '� FAN VENTED CURB UNIT TAG ROOF TERMINATION. `��� NO. GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL CUP DAMPER MOUNT DISCHARGE DAMPER DAMPER MOUNT 1 YES CU B A SEMBLIES \� ''�\ SECURED TO THE CURB BY OTHER. NO. FAN WEIGHT ITEM SIZE , 1 # 1 31 LBS Curb 19.500'4 x 19.500'L x 20.000'H Vented Hinged -- ': LISTED GREASE DUCT. 1 i9 1/2' 19 1/2' \ FAN #1 DU5OHFA - EXHAUST FAN FEATURES VENTED CURB /13 -DIRECT DRIVE CONSTRUCTION (NO BELTS/PULLEYS) \\`0 28 7/8 -ROOF MOUNTED FANS 20' -RESTAURANT MODEL , 1. - ANDUL705 UL762 AND LL-5615 - VARIABLE SPEED CONTROL A 20EGAUGE -INTERNAL WIRING CONSTRUCTION - WEATHERPROOF DISCONNECT MTh -THERMAL OVERLOADOAD PR PROTECTION(SINGLE PHASE) -HIGH HEAT OPERATION 300'F(149'C) 11i111 - GREASE CLASSIFICATION TESTING 3' FLANGE 2] V4 / �_ i� N➢I9IAL TFMPFRATURE TEST EXHI" "I 21 1/2 LESE FAN TUSTING OPERATE T(14CONTINUOUSLY' ROOF OPENING WHILE EXHAUSTING AIR AT 300'F(149'q / DIMENSIONS UNTILRALL FAN PARTS HAVE REACHED 194.:ll . 19 _ THERMAL EQUILIBRIUM,AND WITHOUT ANY �/ 'I�I' DETERIORATING EFFECTS EO THE FAN WHICH GREASE DRAIN DWOULDETER CAUSE UNSAFE OPERATION. ARNORVIL FLARE-UP TEST PITCHED CURBS ARE AVAILABLE 0' 2IMMI =EllEXHAUST FAN MUST OPERATE CONTINUOUSLY FOR PITCHED ROOFS. WHILE EXHAUSTING BURNING GREASE VAPORS I l3 I/4 I AT 600'F<316'0 FOR A PER=OF 0' 15 MINUTES WITHOUT THE FAN BECOMING SPECIFY PITCHY 12' DAMAGED TO ANY EXTENT THAT COULD CAUSE EXAMPLE. 7/12 PITCH = 30' SLOPE— AN UNSAFE CONDITION. 19 _OPTIONS 2 GREASE BOX. 2\R ECM WIRING PACKAGE - MANUAL OR 0-10VDC REFERENCE SPEED CONTROL (TELCO MOTOR), CCW ROTATION. CUSTOMER APPROVAL TO MANUFACTURE: Approved as Noted ❑ Approved with NO Exception Taken X JOBPride King Street Northampton �[ 0 ♦7 rw �� = LOCATION NORTHAMPTON, MA, 01060 Revise and Resubmit ❑ - -- _ice ==� E1� SIGNATURE � �4• �Ct.(79L!/<.Llfi c E1�L.Intent* „ -=_- __ DATE 11/20/2019 JOB # 4078331 Your Title Dote --- '- D1frC 3 BR91f'N BYTSH-37 s'LECTRICAL PACKAGE - Job#4078331 NO. TAG PACKAGE k LOCATION SWITCHES OPTION FANS CONTROLLED LOCATION QUANTITY TYPE 1 H.P. VOLT FLA 05 - SS Wall 1 Light 1 SC-110110FP Wall Mount In SS Box Mount Box Smart Controls Thermostatic Control Exhaust 1 0.500 115 6,3 1 Fan TEMPERATURE SENSOR DETAIL OF REeiOTE E/S BOX 14' r I .L HOOD LIGHTS i I I I I I I I I I E TO CONTROLS 1:1 - I WITH R4 SCREWS L FACEPLATE ® 18 WALL MOUNTED CONTROL CENTER ROOM TEMPERATURE SENSOR CASHMI NOTE: IF MULTIPLE HOODS OR INTERFACE MULTIPLE SENSORS ALL MUST BE FIELD WIRED TO REMOTE MOUNTED CONTROL PANEL ROOM THERMISTOR FAD INSTALLED T-STAT WIRE TO CONTROL PANEL \ I ROOM TEMP SENSOR - USED TO AUTOMATICALLY TURN FANS ON WHEN DUCT TEMP REACHES TEN DEGREES ABOVE ROOM TEMPERATURE. The Electrical natures typically FP,Is designed to ystm.This opt activate the exhaust fans for an exhaust hood whenever elevated temperatures are sensed 0:the exhaust system.This optbn.Al meet the reQuhenents of 1MC 5072.1.1 12 provblhg a j/ /////// ETLthe(U 508AL mounted con In the duct or hood riser t 1 sense increased exhaust temperatures.Controls shall be listed iby t ETL(UL SOBA).The Control enclosure shall be NEMA 1 rated and listed for hstallatlon Inside of the exhaust hood utility cabinet. The control enclosure may be constructed of stainless steel or painted steel. Temperature probes(s)located In the duct riser shall be constructed of Stainless Steel. A room temperature sensor Is also provided for Field installation In the kitchen space In order to start the fan(s)based on the temperature differential between the room and the exhaust air h the duct,rather than fixed set-points.The system Is factory pre-set to activate the fans at 10 deg F.above the room temperature. Once the duct temperature reaches the activation point,the exhaust fans.Ill be activated.The controls also provide hysteresis to prevent cycUng of the fans after the cooking appliances have been turned off and the heat In the exhaust system Is reduced. The hysteresis is factory set 2 degrees and will keep the exhaust running until the temperature falls 2 degrees below the activation set point.A hysteresis timer also exists to keep the fans running for at least 30 Nn after being activated by the Room Temperature Sensor temperature rise. -Install on wall somewhere The octivation and hysteresis settings may be field adjusted on the board LCD Interface located Inside the control enclosure to in the space but not directly meet application needs. The panel Is factory configured to shut down supply fans,turn on the exhaust fans and turn off the under the hood or close to hood lights h a fine contlrcinn. an appliance so that the / \ reading is not affected by it. f Ideal location is under an HVAC return or next to the HVAC thermostat. HOOD PANEL 1 TEAS - , TO KITCHEN TEMPI 1113 WIRE TO CONTROL BOARD. ROOM TEMP SENSOR SENSOR MOUNTED IN Rml AWAY FROM HEAT SOURCES.SEE MANUAL CUSTOMER APPROVAL TO MANUFACTURE, Approved as Noted ❑ Approved with NO Exception Taken X JOBPride King Street Northampton Revise and Resubmit %/ 1 ♦' _ �_wm -s - ___ LOCATION NORTHAMPTON, MA, 01060 �a'�G`L�i 4. �LIiLLJL I EnteI V �•• „ -- O�� SIGNATURE r"==1 DATE 11/20/2019 JOB # 4078331 Your Title Date 0 DIVC # 4 DRAWN BY TSH-37 iuctWork #1 Parts — Job#4078331 Tag Part N CFM S.P. Weight Velocity QTY Description PI DW1247LT 1160 -0.0177 18.70 1476.96 1 Single Wall Duct 12' dianeter, 47' long, Flange at both ends. Stainless Steel. P2 DW1235LT 1160 -0.0132 14.03 1476.96 1 Single Wall Duct 12' diameter, 35' long, Flange at both ends. Stainless Steel. P3 DW1248AJDKIT 1160 -0009I 2274 147696 1 Single Wall Duct Adjustable, 12' diameter, 47.5' long, flange at one end With a 12' . . . Assembled w/P4 Adjustable Collar - Stainless Steel. P4 DW1912TP 1160 0 6.27 1476.96 1 Duct -to Curb Transition, 19-1/2' Curb to 12' Duct, 16 GA Aluminized Steel. Used on Assembled w/P3 BDU11, DU25, 30 8. 33. System at P4 1160 -0.692 3M-2000PLUS 0.80 1 Duct - 3M Flre Barrier 2000 Plus Silicone - Used as sealant to Seal Duct Joints, DW12CLASY 1.23 3 Duct 'V' Clamp With new design 14 Ga Brackets, 12' Duct, Assembly. Total Weight 66.23 INGLE WALL FACTORY BUILT DUCTWORK ALL DUCTWORK IS REQUIRED TO BE INSTALLED WITH THE MAXIMUM SUPPORT SPACING LISTED BELOW. FOR A COMPLETE LIST OF APPROVED SUPPORT METHODS, SEE THE INSTALLATION AND OPERATION MANUAL. DUCTWORK SHALL SLOPE NOT LESS THAN 1/16' PER LINEAR FOOT TOWARDS THE HOOD OR AN APPROVED GREASE COLLECTION RESERVOIR. WHERE HORIZONTAL DUCTS EXCEED 75 FEET IN LENGTH, THE SLOPE SHALL NOT BE LESS THAN 3/16' PER LINEAR FOOT. DUCT DIAMETER HORIZONTAL VERTICAL VERTICAL SUPPORT (ft) WALL SUPPORT (ft) CURB SUPPORT (ft) 8' 10' 10' 24' 10' 10' 10' 24' 12' 10' 10' 24' 14' 10' 10' 24' 16' 10' 10' 24' 18' 10' 10' 24' 20' 10' 10' 24' 22' 10' 10' 24' 24' 10' 10' 24' ® GREASE DUCT & CHIMNEY SPECIFICATI❑NS: PR❑VIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP L❑CKING C❑NNECTI❑NS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" DOES NOT REQUIRE WELDING PR❑VIDING IT HAS BEEN INSTALLED PER THE MANUFACTURES INSTALLATI❑N GUIDE. PR❑VIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTI❑N AND EVERY 12' ON CENTER, PER MANUFACTURES LISTING MODEL "DW" HORIZ❑NTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12", H❑RIZ❑NTAL RUNS MORE THAN 75 FT, CAN BE SLOPED 3/16" PER 12", DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATI❑N IN H❑RIZ❑NTAL RUNS, IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF C❑MBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS OUTER SHELL. CUSTOMER APPROVAL TO MANUFACTURE Approved as Noted ❑ Approved with NO Exception Taken JOBPride King Street Northampton Revise and Resubmit ❑ maimmanom LOCATION NORTHAMPTON, MA, 01060 4. s�a6 ,Ei� �= SIGNATURE DATE 11/20/2019 JOB fE 4078331 Your Title Date �= DIYC # 5 DR4WIV BYTSH-37 DuctWork #1 Top View DuctWork #1 Front View DuctWork #1 Side View DuctWork #1 SE View SYSTEM -.--- t SYSTEM SYSTEMi — P4 I SYSTEM P4 11 t P4 - P3 P3 P4 P3 Y - -21.50 / P2 P2 P2 125.50 MAX 1 12 X 86'MMI 106'N 106 / 1 86'MIN / / _/ P1 P1 �__ - / i Pl El / E1 a 1 C1 CUSTOMER APPROVAL TO MANUFACTURE: Approved as Noted Approved with NO Exception Taken X JOBPride King Street Northampton Revise and Resubmit — __ LOCATION N❑RTHAMPT❑N, MA, 01060 Z7 ` . 'C,6eu�' '`I"' ♦k --� --� DATE 11/20/2019 JOB # 4078331 SIGNATURE �/ � ��� Your Title Dote a ��" a'intertek ® `/� �� W =;� B1'G # 6 DRAIYN BYTSH-37 Exhaust Ian Wiring .,L1„ wuio331 - rriue nrng 3 aree l• rsun l.rrunJ aun DRAWING NUMBER EXH4078331-1 SHIP DATE 11/20/2019 MODEL DU5OHFA Installed Options RD BK •0-10y OPTIONAL 0-10VDC •GND MOTOR • SPEED REFERENCE .24 VAC CONTROL• • INPUT P3 RD BK SC-01 1 TR-01 BK WH WH --- 16 AVG BK 2 o—————] ' r 16 AVG V MT-01 I I VH L_--J x22 AWG WHITE MOTOR R SW-01 ROTATION WIRE. CONNECT TO 16 AWG Component Identification 3 aGR----1 BLACK WIRE TO REVERSE ROTATION Label Description Location 4 MT Ol Fan Motor [2] MT-02 Damper Motor (2] 5 SC-01 RTC-FSC-1 [1] SW-01 Main disconnect switch (2] TR-01 24VAC 20VA Transformer[1] 6 7 8 9 10 11 12 13 14 15 MOTOR INFO 16 EXHAUST O,SHP 115V 1P 6.3FLA 17 18 ELECTRICAL INFORMATION MOTOR/CTRL MCA: 7.9A MOTOR/CTRL MOP: 15A 19 20 NOTES -——- DENOTES FIELD WIRING 21 DENOTES INTERNAL WIRING 22 WIRE COLOR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN BR - BROWN GY - GRAY l RD - RED ORANGE PR -PK PINK PURPLE ` WH - WHITE JOB NO MODEL NUMBER SC-110110FP DRAWN BY SO1EIAPC TYPE DESCRIPTI❑N OF ❑PERATI❑Ni 4078331 INSTALL 120V I Phase s/control forI Exhaust Fan,Exhaust on In Fire,Lights out In Fire,Fan(s)On/Off Thermostatically Controlled. Room terperatre sensor JOB NAME DAIS DWG No sapped loose far fkld Installation. Pride King Street Northampton 11/20/2019 ECP #1-1 BREAKER PANEL TO PRIMARY CONTROL PANEL CONTROL PANE mu. ---AZ-, TO allao WIRE TO CONTROL BOARD. INSTALL Responsibility, Electrician TEMP SENSOR SENSOR ROOM FROM ROOM TEMP BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED SOURCES. DO NOT INSTALL SENSOR _ BREAKER PANEL PRIMARY CONTROL PANEL ON THE CEILING GRID, SEE MANUAL. BREAKER IPH--- --- - _ Ilyt CONTROL PANE RIP:14V {Z}-1 Neutral 10 Ni Ca TO ." VIRE TO CONTROL BOARD. 1•1000 1 - 120 V Ground laim DUCT SENSOR 15 A CONTROL POWER. DO NOT WIRE SENSOR MOUNTED IN EXHAUST DUCT RISER t TO GFCI OR SHUNT TRIP BREAKER. THE FOLLOWING CONNECTIONS HOOD LIGHT BREAKER CONTROL POWER. SWITCH ,HARED V/ MAY OR MAY NOT BE REQUIRED BASED ON JOBSITE Hot SPECIFICATIONS BREAKER 1PH Neutral n-srSHUN COIL 115 V _ Ground imm� CONTROL PANE ma: HOT TO SHUNT COIL , MCA, 7.9 A EXH-1 SIGNAL FOR a- NEUTRAL FROM SHUNT COIL MOCP' 15 A EXTERNAL ST TERMINAL IS ENERGIZED SHUNT TRIP IN FIRE CONDITION. CONTROL PANEAlai COMMON• __ SPARE FIRE ��. NORMALLY OPEN _ D CONTROL PANEL TO FANS SYSTEM DRY SPARE WHEN SYSTEM ISLARMED.MAKE TH THEY CONTACT ARE USED TO DISABLE EQUIPMENT Responsibility, Electrician OR PROVIDE SIGNALS. (NOT FOR BUILDING FIRE ALARM WHICH MUST 7 PRIMARY PANEL FANS BE EARME WIRID DIRICTLY TOCT THE LOANSUL A_ Load Wiring -_MCI !9T FAN, 01 _—— �1 RIM63 IN ANSUL AUTOMAN) BMS SWITCH 2 WIRE DIRECT DIRECT �A/_ a --�a HPI MI VOLT.IlZ V CONTROL PANE OOP --gij/iP� --HI' TO MOM J - TO STARTER WIRE TO EXTERNAL SIGNAL SWITCH THROUGH BMS 3 DISCONNECT SWITCH WILL ACTIVATE ZONE! FANS AND LIGHTS 4 s- C❑NTR❑L PANEL TO ACCESSORY ITEMS Responsibility, Electrician - CONTROL PANEL COMPONENT 6 MICROSVITCH 1 CONTROL PANEL 4440 fic 7 TO FIRE SYSTEMp Cl Cl-E -----I ,NC, - FIRE SWITCH VIRE Cl TO COMMON (I). J B VIRE ARI TO NORMALLY CLOSED<2). Cl TO ARI SHOULD HAVE MS-1 4,NO ClFtf CONTINUITY WHEN ARMED. I ,NC, B IF MORE THAN ONE FIRE SYSTEM, WIRE 1 MS-2 44,40 Fief - IN SERIES AS SHOWN L- LC ,NC 0 , K)ARK1-- J 1 CONTROL PANELALL SWITCHES FACTORY WIRED LA"'CAT-5 CONNECTION —�TO 2 SWITCHES - H000 LIGHTS 1 3 CONTROL PANEL Blcl— BWHITE LACK _j},-1TO b W1� GREEN �-( 1 J- HOOD LIGHTS F T�IY 1- 4 1400 W MAX VIRE TO J-BOX ON TOP OF HOOD A I B I C I D i E I F I G I H I I /FACTORY VIRINI UNLESS SPECIFIED OTHERWISE, ALL FACTORY AC WIRING 16 AWG. ALL FACTORY DC WIRING 18 AWG. MOTOR POWER CIRCUIT SCHEMATIC CI tl zARDS cl I J9 120V PI DCV CUIRev.T 2.11 •'�' HMI Rev, 2.11.0 I►i\0 WH 2MUDD —— CONTROL INPUT 0 S2 14 AWG C-1 MTR EXH-1 Ll i1 YJ BK :1;iC! —— 120V HI=LINE, t PH n CONT 100-K09➢IO � .�KI BK �efc1 Ri __ N1=NEUTRAL, 15A 24V 1 115 V H L T FHP.6.3 R20 AC 24�V [MIA® BREAKER. DO i �� ©® NOT CONNECT 4V J6 QQ 2 3®OO©C RELAY 3 NO R4 LA BK I 1(.oi 47) AT o, -- TO SHUNT TRIP 00 DC 1--, NC 2I T NC i COIL 8 7 COIL a Ce - Ill 1.(6 BK ALycA -- BREAKER, SEE 1:1101 m INSTALLATION O©O C • - COM 6 5 COA+�5 BK SCHEMATIC FOR WI.f'i A1'fN -- ADDITIONAL REQ. a c (COMPONENT LISI AIM0 -- 1 11 LABEL PANEL LID•I GI CI —— i z= s T DESCRIPTION 0varies OL-X Overload varies C-X Contactor varies PS-1 Poeer Supp.24VDI 111P18-21A-IC RA-x IRON4.11D01 Rela84.0yy SPOT 3 RD-x 24VDC Ligght Rela 34.110.0188.0 1 J7 120V L ..L n_ �u ® BK I4AVG RYI 1 BK <H1 F 66 � ) ® BK ®HOOO iHTS UMPER"Nl ®=® rs-r BK fRx1 nv1 i NI DC+►BL OLQ FI PR-4 ROI AR1►BK 61 110 WH-.N1 • LEGEND ---FILLD W121PG —FACTORY VBBN EK-BLACK YV-YELLEN B--9..1.E GY-OREY 92-WINN PR-PURPLE ER-ORFACE RD-RED DRY CONTACTS (SHOWN DE-ENERGIZED) wi+-ATE GR GREEN - 14 AWG RA-1-1 (R/BL-CR/IL STRIPE -— • ON/OFF BL/RD-BL/RD STRIPE MAKE UP AIR INTERLOCK. -— .E�';� , WITH FIRERD/GJ-RD/OJ STRIPE JUMPER WrVBL-VH/BL STRIPE L.S1 • JB NNE Pride . Stree,,. JIO v- MG I ECP403 SC-110110FP DESCRIPDGN OF OPERATION I20V 1 Phase d control For I Exhaust Fan, Exhaust on In Fire, Lights out In Fire,Fens On/OFF Thermostatically 1 Controlled. Roan temperature sensor shipped loose for field Installation. ) JOB NO DRAM BY 417: MISDATE I {I 14 x 18 x 6 Box DMC NOECP k1-2