Loading...
38A-121 BP-2022-0362 57 OLANDER DR COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 38A-121-001 CITY OF NORTHAMPTON Permit: Alts Renovations Repair PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # BP-2022-0362 PERMISSIONIS HEREBY GRANTED TO: Project# heat pump Contractor: License: Est. Cost: 11250 WYATT ROBERTS 106523 Const.Class: Exp.Date: 12/03/2024 Use Group: Owner: GREEN FEIDEN WAYNE & DENISE Lot Size (sq.ft.) Zoning: PV/SG_a/SG b Applicant: DANDELION ENERGY Applicant Address Phone: Insurance: 333 NORTH BEDFORD RD SUITE 220 (845)649-6073 WC038394824 MOUNT KISCO, NY 10549 ISSUED ON:04/11/2022 TO PERFORM THE FOLLOWING WORK: GEO THERMAL HEAT PUMP POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Gas: Final: Final: Rough Frame: Rough: Fire Department Driveway Final: Fireplace/Chimney: Final: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: I .; . Fees Paid: $73.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner f ECEIVE -) -- r t f iY APR - 82022 4, The Commonwealth of Massachusetts Board of Building Regulations and Standards FOR OF f3U1LI�tn)[;{NSPFC t 1 meµ_ c.._._ri__a�:__n_ _ non nw m MUNICIPALITY •1 / 1(�r�Tl'"{AMP¶ON.'.�n n1 LW)V�W t.., V LLL11LLlllb�V\LV, �VV USE Building Permit Application To Construct,Repair,Renovate Or Demolish a Revised Mar 2011 One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: i✓g- ,- 3(/L Date Applied: KEklIL.? r 1Z53 /7/2 LH/-zvzz Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers 57 Olander Dr,Northampton,MA 01060,USA z Q�Q , 12 i I.is iS wia ail awcpicxi DUcci.yw Number�nO — Map (, ' Parcel*,...ber 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard I Side Yards I Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public 0 Private El Municipal_ Outside Flood Zone? Municipal B On site disposal system ❑ Check if yes0 evr.rtriv. 1. PDl1Pvonry nl1/NFDeuwi 2.1 Owner'of Record: Wayne Feiden Northampton,MA 01060,USA Name(Print) City,State,ZIP 57 Olander Dr (408)691-8289 wayne®feiden.org No.and Street Telephone Email Address SEc TiioN 5:u13CRi TON CA.:iRG & Er,1IGRK'(ciivs:w au iuui apply) New Construction 0 Existing Building 0 Owner-Occupied 0 Repairs(s) 0 Alteration(s) la Addition 0 Demolition 0 Accessory Bldg. ❑ Number of Units Other 0 Specify:Geothermal Brief Description of Proposed Work2:Install one 3-ton geothermal heat pump,closed loop system. SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building $ 1. Building Permit Fee:$ Indicate how fee is determined: 2 Electrical 0 Standard Cityrrnwn Application Fee 0 Total Project Cost3(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $11,250 List: 5. Mechanical (Fire $ Suppression) Total All Fees: :"::;.;,::..... I Check P..-:zu. I C.::.:~.,�..... 6.Total Project Cost: I $11,250 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) I CSFA-106523 12/3/2024 Wyatt Roberts License Number Expiration Date Name of CSL Holder 333 North Bedford Road,Suite 220 List CSL Type(see below) R No.and Street Type Description Mount Kisco U Unrestricted(Buildings up to 35,000 cu.ft.) R Restricted I&2 Family Dwelling l.1ty/1 te,G M Masonry ik RCRoofing Covering WS Window and Siding SF Solid Fuel Burning Appliances 845-649-6073 JDeVore©DandelionEnergy.com I Insulation Telephone Email address D Demolition n..,.:..a,,.....a a ... T....._ ., .„ »s n....s......4....RITE I � _. __ _-- . ..._ ». »_. . �---„� 201508 2023/04/11 Dandelion Energy HIC Registration Number Expiration Date HIC Company Name or HIC Registrant Name 333 North Bedford Road,Suite 220 hkowaiski@dandelionenergy.com No.and Street Email address Mount lesco,NY 10549 860-301-7100 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes 0 No .❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize Dandelion Energy to act on my behalf,in all matters relative to work authorized by this building permit application. Wayne Felden See Attached Authorization Clllll VWI1G1 J 1'4111G tB1GLh1V111G Ji 114LWG/ 1Jg4G SECTION 7b:OWNER1 OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to e my knowledge and understanding. Hannah Kowaista of Dandelion Energy .5/29/2022 Print Owner's or Authorized Agent's N ) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Irif j :.t _n__... ,.=i__ ":}c. '..,c._...., ,_r_.._a c'www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for`Total Project Cost" CITY OF NORTHAMPTON SETBACK PLAN MAP: LOT: LOT SIZE: REAR LOT DIMENSION: REAR YARD See Attached SIDE YARD SIDE YARD FRONT SETBACK FRONTAGE The Commonwealth of Massachusetts '*l41�1=`rx Department of Industrial Accidents •.:r1= ' 1 Congress Street,Suite 100 }:r= Boston,MA 02114-2017 www.mass.goir/dia 11 e.kers'('ompensation Insurance Affdas it:Builders/('ontractors/Ekctriclans:Plumber.. ro HE FILED 11 Ff0 Ililt PERMITTING AI'TNOWTI. Annlicant Information Please Print Legibly Name 1 Husiness Orgi nication Intin tdu.tl i Dandelion Energy Address: 333 North Bedford Road,Suite 220 City/StateiZ►p:_Mount Kisco,NY 10549 P}tone _c 880-301-7100 Are yes so eseplayer?(trek the appruprlatr hot: Type of project(required): 1.0 I sits a encluyu xlib 140 enyeloyesa(full and or part-tinsel• 7. 0 New construction =D I am a wine proprietor us partnership and hate nu employees working for ne in S. O Remodeling am capacity INu x oilers•comp.Inauraner required] 9. EI Demolition tCI I Am a homy,.nee doing all*oil myself.Igo workers.comp.uauranci nqutr►tl.I' 4.0 lam a'summoner and vs ill be hums contracture to cundust all work un my prupeity. I will !0 O Budding addition eruore that all c.rntrawtun either hate Noreen'compensation insurance or are sole i i.a Electrical repairs or additions prupnetor'with no ctnpluycca 12.0 Plumbing repairs or additions 50 I am a Inrrrai contractor and I hat c hued the sub-contractors limed un the attached sheet. The sub-eunirxtun hate employees and hats workers'comp.tissue-since., i 30 Roof repairs Thew 14.®Other Geothermal 6.a We are a corporation and it.officer,hat e exercised then ntht of exemption pet Mt�L c. - 152..1141.and we hate no employees.iNo workers'comp.insurance required.] *Any applicant that chocla but III must atw till out the section below showing then workers'compensation pulley infunnauon Homeowner,xho aubnut this acrid as a mdxat:nu they are doing all work and then hue outside contractors mint auhnut a new aftidas it indicating suit. :Contractors that check this hot must arta:heti an additional sheet thou.any the name of the subcontractors and gate a helher or nut drum: hate emplu,:.. It r•I.-.ecs.ths inu,lpr. .odethen ., •tl.c , :.•r.ip it,is,-,Li:J,a I am an employer that is providing wurAera'compensation insurance for my employees. Below is the polity and job site Information. Insurance Company Name: NOW Hampshire Iris Co . Policy it or Self-ins.Lie.#: WC038394824 NY Expiration Date: 7/1/2022 Job Site Address: 57 Olander Dr,Northampton,MA 01060,USA Ci "State Zi Northampton,MA 01060,USA Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152.*25A is a criminal violation punishable by a fine up to S 1.500.00 and;or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to S250.00 a day against the s iolator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coy era_e verification. I do herehy cer ' •un er tit• eein.a un ties of perjury that the information provided above is true and correct. Si mature: Iltt: 3/29/2022 Phone v: 0-301-7100 Official use only. Du nut write in This area.to he completed by cite or town official ( its or I uw n: Per mili License ss Issuing.tuthority (circle one): I. Board of Health 2. Building Department 3.City Town Clerk 4. Electrical Inspector 5. Plumbing Inspector ti.Other Contact Person: Phone#: DocuSIgn Envelope ID:BC335BE4-61FF-40EA-A795-BDC161B4C99E DANDELION Date: 2/13/2022 ATTN:Building Department Subject Property:57 Olander Dr,Northampton,MA 01060,USA 1, Wayne Feiden ,as Owner of the subject property hereby authorize Dandelion Energy,and its representatives,to act on my behalf in all matters relative to work authorized by the enclosed building permit application. X_ f�►�11h f_,�,l In -1-,U-1:IA ;I::; (Signature of Property Owner(s)) DANDENE-01 EPRZEBIEGLEC ACORO CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 9/10/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the poiicy(Ies)must have ADDITIONAL INSURED provisions or be endorsed. if SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). CONTACT -- --: NAM: York international Agency,LLC ,_(914)376-2200 I W#c,1144914)376-2891 500 Mamaroneck Avenue Suite 220 vase certMcate@yorkinacoln Harrison,NY 10528 INSURER($)AFFORDING COVERAGE NOG INSURER A:Hamilton Insurance Designated Activity Company MSURED INSURER a:Merchants Mutual Ins.Co. 23329 Dandelion Eneray.Inc. INSURER C: 333 North Bedford Road,Suite 220 NSURERD: Mount Kisco,NY 10549 SOURER E INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. t TR TYPE OF INSURANCED AOOLIWWMLUR POLICY NUMBER �ODI Y n POUCY�) UNITS A X COMMERCIAL GENERAL UABIUTY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE OCCUR ENVPKGH1803226 9/8/2021 9/8/22022 NET GesEsTUENTED ) _ .50,000 MED EXP(Any one person) $ 5,000 .__ PERSONAL&WV INJURY $ 1,000,000 GEN.; AcuaRFRATF ILIIMIIT APPI IFS PER. GENERAL AGGREGATE f 2,000,000 X I POLICY I JECT I i LOC PRODUCTS-COMP/OP AGO $ 2,000,000 OTHER: j B AUTOMOBILE LIABILITY GOMBI SNGLE UNIT $ 1,000,000 X ANY AUTO CAP1079447 7/5/2021 7/5/2022 BODILY INJURY(Par Oerwn) _ OWNED SCHEDULED AUTOS ONLY AUTOS yy pBOOpDIILY IINJJUpMRAY(APeer occident) $ X AUTOS ONLY X AAUTdOS ONLY (Per eeMdenE @ E $ I I UMBRELLA UAB OCCUR EACH OCCURRENCE EXCESS LIAR CLAIMS-MADE AGGREGATE _ DEO RETENTIONS $ WORKERS COMPENSATION PER RTllTE AND EMPLOYERS'LIABILITY YIN ANYpp PROPRIETOR/PARTNER/EXECUTIVEE EL EACH ACCIDENT OFFICEER/M In BER EXCLUDED? N IA - (Me NN EL.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remark.Schedule,may ba etta hed N mom was le required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Dandelion Energy,inc. THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 333 North Bedford Road,Suite 220 Mount Kisco,NY 10549 AUTHORIZED REPRESENTATIVE 90•Aaro... ACORD 25(2016/03) ®1988-2015 ACORD CORPORATION. All lights reserved. The ACORD name and logo are registered marks of ACORD ACCPRE, CERTIFICATE OF LIABILITY INSURANCE I °"'�""i2021 1,/23I2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATiun.unity iuvu a.uNFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.T iiia CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Services, CACT Inc -� NAME: Aon Risk Services.Inc of Florida 1001 i,FL 33 Bay Orinie,Suite#1100 PHON(NC,No,Ems:800-743-8130 FAX No):800-522-7514 Miami,FL 33131.49:t7 EMAIL ADDRESS: ADP.COI.CenteretAon.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: New Hampshire he Co 23841 INSURED INSURER B: ADP TotalSource CO XXIIL Inc 10200 Sunset Ddwe INSURER C: u,..,..I n ra 1 vo ,L/C/F INSURER D: I Dandelan Energy Inc DBA INSURER E: I 333 N Bedford Rd, 1 Mt Kisco,NY 10549 INSURER F: COVERAGES CERTIFICATE NUMBER:3770023 REVISION NUMBER: THIS IS TO CERTFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD NDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAD CLAIMS. lNSR' TYPE OF INSURANCE ADDL SUeR POIJCY NUMBER POLICY EFF POLICY EXP LWITS LTR INSR WVD (I1111/13D/YYYY) (MWDD/YYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGE TO RENTED CLAIMS-MADE OCCUR PREMISES(Ea accvrence) $ MED EXP(Any one person) S PERSONAL 8 ADV INJURY $ GENT_AGGREGATE Limn'APPLIES PER: GENERAL AGGREGATE S ..—Ir—r r1 POLICY LJ PROJECT) I LOC PRODUCTS-COMP/OP AGG S OTHER LIM i &�LIABILITY COMBINED SINGLE IT (Ea accident) f ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED _AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ HRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY _AUTOS ONLY (Per accident) $ _UMBRELLA LIAR OCCUR - EACH OCCURRENCE $ EXCESS LAB CLAIMS-MADE AGGREGATE $ DEC I I RETENTION$ WORKERS COMPENSATION X A PER OTH- AND EMPLOYERS'LABILITY YIN STATUTE ER A ANY PROPRIETOR/PARTNER/EXECUTIVE ri WC 038394824 NY 01/01/2022 07/01/2022 EL EACH ACCIDENT $ Unlimited OFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) E.L DISEASE-EA EMPLOYEE $ Unlimited DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT I $ Unlimited I I DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) All worksite empbyees working for DANDELION ENERGY INC DBA,paid under ADP TOTALSOURCE,INC's payrol,we cowed under the shows slated poky. I I CERTIFICATE HOLDER CANCELLATION Danaeton Energy Inc SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 333 N Bedford Rd THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Mt Reco,NY 10549 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE °lion(kisk 8etviee6, 2nc of�flotilla 01988-2015 ACORD CORPORATION.Ali rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD - Nx "T.....,-,z.,Ws''' ''1.1)-kk`.*, '., , , -.s44,N,?3411Nx%Iss.' s.N.x.s‘vkl.s.v44..x.vt,Nivaks.‘"\k•NW. \\\\,\%: - - . ' NN ,,,,,,, .i. \\1/4„ \\\ \ \\\\ Commonwealth of Massachusetts - - ' ‘ ,.,.. - ',. Division of Professional Licensure k \ ,iv: Division Board of Building Regulations and Standards % 1,%,,,,., ‘‘ \ . Construction Supervisor --.- . \ „„,\,‘‘,•...,4 ,. ,,..,,,,,,.,N..z.:„. .„.,-• CSFA-106523 4twol Expires: 12/03/2024 , -""-:::"':-*C11•4,-,-, ‘\"•,,,„ , ,.. . 11/1".11144* •-:%:14,kk .4% .,.'k ' '' '..„ -. VVYATT ROBERTS i ' - ' \ : 333 NORTH BEDFORD RD STE 220 , ,, \'`\ , ,, ,,N.s4N.:^‘N:.., MOUNT KISCO N`f 10 . • , .1011/// -N,NiNN.,k , ''''',. s'''. ... , . ..,., • , ..• ,...„.„. ,, „„.. Jczi,2k , .. . . Commissioner ic [ I . ! , . ..4.•,, s, ,,,,,•.4:‘,.z.,w.:•. . .'t ' , \ N 1 .. .. * it Zilly 1 $ .„.# • T{ a i41 �!!, .�:" T] a �, .tom r .- '3 ,. , .•% `` i ♦. 111 ' { t 1\\ '... ft.. 1111 lifit‘M.6118‘1111111131.- *2 _ , \\ 0 k. of NDER 001 R - 1 •ft woo. .1 a 4'6. 1-t* lit:1114: , ,te. • j' 4111111 .....___._._.___..._.--- ) . • N........0...........Z....._....... .....••••••••••ww*II". ( : . At/4 ss ‘. r i r7 ._. ,..:.,.. . .... A ..,cb RYAN G= �; 1. �, 4 _. i,,,,,,,, ., • . , ... . s.6, . M ',,9o�FJE6KiERE�`��`�,. _...>.. � .. j j/OMALENb�. CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: DESCRIPTION: PAGE: DANDELION Feiden,Wayne 57 Olander Dr,Northampton,MA 01060,USA SITE�"" s w4 VERSION V2021.11 DRAWN BY: AA PROJECT ID: 21-010-0556 DATE: ZOZZ�O3.27 """ '��"�°' �A�' �"�""'" 1AlM/GlpuoslMotngx6Aursnm SCALE:SEE COTS SIZE:ISO B_].SX17 OMNI HIM'mIg11Af0lIYM1CMI.IOAI.101T! p1MMI,M/IMWN. ID LOOP 1 Z TYPE VERTICAL BORE •• .......•..... —_ NO.OF BORES 1 BORE DEPTH 359 BORE SPACING 18 FT EST.DEPTH TO BEDROCK 61.02 FT �u U-BEND DIAMETER 1-1l4IN I — U-BEND MATERIAL HOPE 4710 DR-11 I �. GROUT CONDUCTIVITY 1.2 BTU/HR-FT-F f HEADER DIAMETER 1-1)2 IN *j HEADER MATERIAL HOPE 4710 DR-11 Enclosed Porch: EST.TRENCH LENGTH 56 FT $ 167 rt' TIE-IN TYPE BELOW GROUND HOMEOWNER OBLIGATIONS&EXCLUSIONS •Remove fence •Remove walkway Attached Garage: •Remove pavers 539 It' DESIGN NOTES FOR DRILLING: •None DESIGN NOTES FOR TRENCHING: •None HEADIER it \ 1st Floor: 1074 R' 2nd Floor: 1074 x 0.5=537 ft 2 \00111.nnpgrry I Open Porch: ,�4E,'`tN OF MA"!/."‘.',r 84 R: Oif.: yG z WASTE i v 73t -$. RYAN J. Iascracaw el CAIBM 4_ II WATER St IPPLY =" No.55865 f"' I r GAIIFUC PPE 1'A,'`*EBISTE0.4./.."$ I I %,"eSSIONAl1E*� `'s e ue. CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: DESCRI'PTION: PAGE: DANDELION Feiden,Wayne 57 Olander Dr,Northampton,MA 01060,USA DETAILED SITE PLAN 2 of 4 .,r omens wnwernaa la.. v4w�uo VERSION V2021.11 DRAWN BY: AA PROJECT ID: 21-010-0556 DATE: 2022-03-27 "r"xiw....":4° c=""'" SCALE:SEE NTS SIZE:ISO B_ 11X17 w1esow11a.Ma•r"rew.MroR m,r nb OIMwMMMNYM 1 EXISTING EQUIPMENT TO BE REMOVED: N F1-FURNACE FUEL TYPE: INATURL GAS A AC3-AC CONDENSER Ga REFRIG.TYPE: IR-410a g WH1-WATER HEATER SIZE 50 GAL FUEL TYPE NATURL GAS UNFMfSHEO PIPING 1-COPPER e95;a G > 1P WH1 -EMOV F1 w -REMOVE AINIIIIIIIIIIIIIIII • EXISTING EOUIPMENT TO BE REMAIN IN PLACE: STRO I MSP1-MAIN SERVICE PANEL • SERVICE RATING 200A BRAND MURRAY IIV 111p%11111 /1 PROPOSED BREAKERS TO REMOVE: AC1 ,E'AN OF y,Fs',,,,,! •MSP:11,13 and 15 EMOV °off ``go HOMEOWNER OBLIGATIONS&EXCLUSIONS: =A RYAN1 1�= •None ="\ No.551S5 "- DESIGN NOTES FOR INSTALLERS: 4 •None "r.0 lif.fISTie �Wl,�`�� BASEMENT °```4/ _.._M6�+, 41, OMAL1E11111. CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: DESCRIPTION: PAGE: DANDELION Feiden,Wayne 57 Olender Dr,Northampton,MA 01060,USA EQUIPMENT REMOVAL PLAN 3of4 21/CCORIAfl MIIIMIG21f.PfC�IK • VERSION V2021.11 DRAWN BY: AA PROJECT ID: 21-010-0556 DATE: 2022-03-27 "1pv/°•w+nu°'2'm"s•nawo au2rwmK 21•sllClfeUmin.2LAIMURA I,m® SCALE:SEE NTS SIZE:ISO_B 11X17 YINI MaMAWmI41lNi�211114i AKll1TI� YMM••MIIMM. �� NEW EQUIPMENT TO BE INSTALLED: LOOP 1 GROUND LOOP TIE-IN 25 FT FROM NW CORNER ID HP1 EQUIPMENT PACKAGE HEAT PUMP 1-1/2 IN HDPE UMW BRAND ENERTECH YT 20 GAL OF GLYCOL SIZE 3 TON DISTRIBUTION FORCED AIR a , AIRFLOW:HTG/CLG 1,380 CFM 11,420 CFM 1 uu SUPPLY VERTICAL RETURN MULTIPOSITION UF"'SHED ari•:ayr ELECTRICAL 40A-240VAC 696•ab I. AUX HEAT YES,60A-240VAC ELECT DISCO REQD YES j° DESUPERHEATER NO WH1 THERMOSTAT ECOBEE NEW HP1 TSTAT WIRES EXISTING 4,6 WIRE • NEW CONDITIONED AREA WHOLE HOUSE srnD I 1 DUCT ZONING YES,2 ZONES AEROSEAL YIN NO • GROUND LOOP LOOP 1 ID WH1 EQUIPMENT HEAT PUMP WATER HEATER BRAND AO SMITH SIZE 80 GAL ELECTRICAL 30A-240VAC ELECT DISCO REQD YES PIPING 1 IN PEX klii limmk `"01p,piu Ulry0p o"40,`�N DF y..!"G/ DUCTWORK MODIFICATION DETAILED INSTRUCTIONS: ,;1 �" y •None = o CAADA - HOMEOWNER OBLIGATIONS&EXCLUSIONS: =" No.55865 1" •Remove and repair drywall DESIGN NOTES FOR INSTALLERS: BASEMENT ''�•-.REcrsrEaE° *''off'�SIONiii0,ks \ •None �°mullNA a" CONTRACTOR NAME: PROJECT NAME: PROJECT ADDRESS: DESCRIPTION: PAGE DANDELION Feiden,Wayne 57 Olander Dr,Northampton,MA 01060,USA NEW EQUIPMENT PLAN r•aacr•z wm m,iaa .nMwseMawowr 4 of 4 rww cnrs"IorwItt Asir re•wnnra: VERSION V2021.11 DRAWN BY: AA PROJECT ID: 21-010-0556 DATE: 2022-03-27 w..a.n.ru,aneebwe�e,a�m.m RrAI E:SEE NTS SIZE:I50_B ]iX17 wuaewwwMINEP1a1wrwn+ew,m•ueInw owDrwrnww, 4/, Dandelion Heat Pump Packaged Unit Performance Ease of Maintenance • Two-stage Copeland®UltraTech* • Real-time performance monitoring and compressor with efficiency values up to advanced diagnostic capabilities with home wifi • OM 4.5/20.9(COP/EER) connection.Comes standard with every unit. • Unique compressor isolation technology • Removable cabinet panels and removable and high-density foam cabinet insulation control box providing easy access to internal for ultra-quiet operation components. • EnergyStar certified and made in the USA • Aluminum microchannel air coil which eliminates • Qualifies for the federal tax credit and the potential for failure due to corrosion, • E' other state/local incentives enhancing reliability and efficiency ,, -_—— — - • Corrosion-proof plastic drain pan and conden- r sate overflow sensor to protect against potential overflows due to clogged condensate drains • 3-year workmanship warranty and 10-year Simple Installation limited parts warranty \•:` i --- ai • Vertical air supply with multi-position, • Digital controls which provide a variety of field field-selectable left or right side return selectable settings for each installation,and ENERGY STAR • Universal connection sizes for ground loop, advanced safety controls to protect the desuperheater and condensate connections equipment • Variable speed,constant cfm ECM blower • Factory-installed soft start which reduces the designed to adapt to connected ductwork start-up power of the heat pump by 70%. and operate at a fraction of the cost of a • Optional field-installed internal auxiliary heating conventional blower motor Performance Ratings Heating Cooling MODEL LOAD SIZE CAPACITY(BTU/HR) COP CAPACITY(BTU/HR) EER BREAKER SIZE(AMPS) YT-024 Full 2 Ton 19,000 4.3 27,100 19.9 30 Part 15,200 4.8 21,400 28.2 YT 036 Full 3 Ton 29,100 4.5 41,200 20.9 40 Part 23,300 5.1 31,500 31.3 YT-048 Full 4 Ton 39,900 4.3 53,300 20.2 40 Part 32,000 4.9 42,600 29.6 Full 49,200 4.1 64,300 19.3 T 0 Y60 5 Ton 50 Part 37,700 4.6 50,000 28.0 YT072 Full Ton 56,200 3.8 71,900 18.0 60 Part 45,800 4.4 58,500 24.8 Rated in accordance with AHRI/ISO standard 13256-1,which includes pump penalties www.dandelionenergy.com 41 Dimensions - 1.00-7, r-----®-- 1s--.. 4.70 O - - -- _5 --- "--16.0 -7.25-' n•P 16.0 TW Ili O0III I■rr1 O I_ _I6.56. . • i - y I- -I* - t� - ♦ E"w.each R.comm.nds a Minimum of to 2.5 feet of S.rvla&nwhdon Accra et Front end N.Coil Sid.. 1.- t 16.0 TOP VIEW TOP VIEW • Showing Optional Filter Rack l 1. I- E 1.00 ' El --1.: IL L a ,, ..., I SO4!! WATER SOURCE 1 I I! HWG WATER-- WATER 0 ® IN =':lf OUT CONFIGURED AS CONFIGURED AS SIDE DISCHARGE BACK DISCHARGE R CP Note:Side and Back Discharge configurations are only available in 036 through 072 models. LEFT VIEW FRONT VIEW Unit Dimensional Data MODEL WITHOUT WITH RETURN SUPPLY OPTIONAL CONTROL BOX CONTROL BOX AIR FLANGE AIR FLANGE FILTER RACK Al *B C A2 D E F G H J K L M N P R 024 46.0 23.0 26.5 53.25 25.0 20.0 19.1 1.92 3.63 11.62 12.5 7.44 1.05 2.34 3.00 3.63 036-048 54.0 25.4 30.5 61.2 28.0 26.0 23.7 2.34 2.25 16.0 16.0 7.26 1.60 2.34 3.29 2.25 060-072 58.4 25.4 30.5 65.6 32.0 26.0 24.0 2.34 2.25 16.0 16.0 7.26 1.60 2.34 3.29 2.25 Notes: All measurements are in inches. Electrical connect.are 1"for high voltage,1/2"for low voltage. *B(Unit Width)excludes field installed factory supplied flanges. w.arloop Wow Cal forWrw Performance Monitoring 38.19 n= Heat pump comes standard with real-time monitoring to provide the installer .,34b!,. S /, and homeowner with remote insight into system performance.This includes 9.66 real-time efficiency,energy usage,and status of the refrigerant,air,and ----- ground loop circuits. y 2.42 ' x *y 94.25 ts.aalrane ..- I www.dandelionenergy.com DANDELION April 23,2021 RE: Insulation requirements for shallow header trench installations To whom it may concern: Dandelion requires excavation and header pipe installation to a minimum depth of 4 ft.below grade,and that depth be maintained from the ground loop location to the building entry point.This requirement is consistent with industry-accepted best practices. However,there are cases where the minimum trench depth cannot be achieved without excessive complication,labor or cost.Dandelion has developed an alternative procedure for such cases,which is outlined in our Design&Installation Standards: When the site conditions prevent the header trench from being excavated to the minimum 4 ft.depth,the exterior header piping shall be insulated with closed-cell pipe insulation.Additionally,foam board insulation(min.R10)shall be installed directly above and along the outer edges of the piping in the bottom of the trench for additional freeze protection.The width of the foam board insulation shall be sufficient to completely cover the header piping so that it cannot be seen from above prior to backfill. The thermal conductivity of subsoil is typically on the order of 0.50-1.00 Btu/hr-ft-°F,depending on composition,density and moisture content.The thermal resistance of foam board insulation is R=5 hr-ft -'F/Btu(per inch of thickness).Using the steady-state conduction equation to calculate thermal equivalence(R=L/kA),it can be shown that adding 2 inch (R10)foam board insulation is comparable to adding 60 inches of soil depth,at minimum. Although it is not ideal to install header piping at depths less than 4 ft.from the surface,the installation of foam board insulation in accordance with our Design&Installation Standards will compensate for the deficiency from a thermal performance and more importantly,from a freeze protection standpoint. If you have any questions,feel free to contact me ar rrardanrlanrlelinnanar rnm. Sincerely, Ryan Carda,P.E. ��‘.0�.1%OF M.46/.„��� Principal Engineer .�, : "" .. Sir os Dandelion Energy,Inc. 1/ RYAN 1. o► URDA -. No.55865 `‘\‘ 4fSJON4 ,EN6�` April 23,2021 \!� - 33S Madison Ave,4th Floor O New York,NV 10017 DANDELION September 15,2020 RE:Compliance with applicable codes and regulations To whom it may concern: Dandelion requires that all design and installation methods and materials comply with all applicable codes and standards, including ANSI/CSA/IGSHPA C448 Series-16(Design and installation of ground source hear pump systems for commercial and residential buildings) and Massachusetts State Building Code and State Energy Code. We provide a set of internal Design & Installation Standards, Permit Drawings,and Master Service Agreements to enforce this requirement with third party contractors and internal installation crews alike. Therefore,to the best of my knowledge, belief and personal judgment,our permit drawings,design and installation requirements and scope of work comply with Massachusetts State Building Code and State Energy Code. If you have any questions,feel free to contact me at rcarda@dandelionenergy.com. Sincerely, Ryan Carda, P.E Principal Engineer Dandelion Energy, Inc `\ �.0 OF NA;�f'`y / R . J. o CARDA No.55865 90 �FCISTEItE��'E�Q;. '''�fsStONAI O335 Madison Ave,4th Floor New York,NY 10017 DANDELION Re:Sediment control practices for permit application to install a ground loop as part of a geothermal heating and cooling system installation To whom it may concern: This letter summarizes Dandelion Energy's sediment control practices as part of our permit application for geothermal heating and cooling system installation. Dandelion implements industry accepted sediment control methods during drilling and trenching activities in general accordance with New York State Department of Conservation Standard Specifications for Erosion and Sediment Control. The sediment control method(s) implemented on each project vary depending on site-specific conditions,but include one or more of the following measures: • Mud Processor - Equipment used to manage and process drilling spoils by separating solid and fluid materials removed from the borehole. • Containers - Drilling spoils are typically discharged directly into containers such as heavy-duty woven polypropylene sacks, impermeable 3-ply plastic pools, geotextile filter bags or lined roll-off containers during drilling. • Stockpile Methods - In some instances,drilling spoils or excavated materials from trenching may be temporarily stockpiled and contained using silt fences and/or straw bale dikes to prevent runoff. Excavated material is typically returned to the trench on the same day. • Dust Control - Water is sprayed to wet drilling spoils or excavated materials for dust control as needed. These practices have been developed and are employed to ensure that the highest level of environmental protection is achieved as a normal part of system installation. Thanks in advance for your consideration. Sincerely, O AN F �Sa ................. ..y ; RYAN J. am.r, o CARDA No.55865 qp� �FG/STEQE..`�� //, Ss/ONAE E76\ ////unnni Ryan Carda, P.E Principal Engineer Dandelion Energy, Inc \I/ O335 Madison Ave,4th Floor New York,NY 10017 PERFORMANCE RATINGS(AHRNSO 13256-1) MODEL CAPACITY COOLING HEATING PRESSURIZED RETURN AIR DUCT FLOW CENTER CAPACITY(BTUIHR) EER CAPACITY(BTUMR) COP CONNECTION (W/ FULL LOAD 27 100 19 9 19.000 4.3 r VIBRATION BREAK YT-02d PART LOAD 21.400 28.2 15 200 4.8 _ I AND RACK)FILTER tt-0 FULL LOAD 4136 .200 20 9 29 100 4 5 { u i,,,,,,,, PART LOAD 31 500 31.3 23 300 5.1 -. a `.`,` 1N OF y VT-0� trZ FULL LOAD 53 300 20.2 39 900 4.3 EXPANSION TANK i �� fS,'.� PART LOAD 42.600 29.6 32.000 4.9 a a a j' IVAN A i z TT-080 FULL LOAD 64 300 19 3 49 200 4.1 _ of uum(I }S PART LOAD 60 000 28.0 37 700 46 ? ; ? NO• S N= FULL LOAD 71.900 16.0 56 200 3.8 rau .�y YT-072 PART LOAD 58.500 218 d5 600 1.1 %7,\ .f.m W, , nn�llaa ROUGH GRADE ' r 0, SEAL BUILDING ENTRYI x/ I .uniaN ACCESS PANEL J7/ 4 r . 0u S' 'iI'iEIiDEi ACCESS �� CHECK VALVE PANEL EH-- _ (WHEN REQUIRED, SEE NOTES) iiii I p ISOLATION BALL VALVE (REQUIREC) F o LEGEND -- E MR SEPI RATOR sus PRESSURIZATION DUALS CONDENSATE-O BALL VALVI-NMJAL RANGE MN. MAX. APPROVED PlI IP OR DRAIN STM1-UP P-FSSURE 90 P9 60 PSI PER AHJ(TRAP REQUIRED) DRAIN VAL':44AMNAL 1""•"'•"11 FLEXIBLE PIPING NOTES: CONNE:T LAIRSON OANOEUONNR OPEMTION IS Eill SP ELBC NINTH PAIIAAM TER COOLING _ MATING LEFT SIDE RETURN f HOWN.UNIT CAN BE CONFIGL iED FOR EITHER LEFT-OR RR HT-HAND RETURN.CONNECTI]NS PREENS(R PORT MIN EAT WI 46S MIRRORED FOR RX31 R HAM)CONFIGMATERIALS, HOP • APPROVED NTERIOI PIPING MATERIALS:HOPE,Pf X AND/OR RUBBER HEATER HI)SE.REFER TO DANDELIONS I ESON A TE= MAX EAT 100•F BON INSTALLATION STAN LARDS FOR SIZING REQUIRE-M:3nS. CONNECTIOI I-0ENERAL PIPI NO MN EAT jp•F 2p•F SUPPLY-RETURN LIN_SIZES SELECTED PER DAND•-IONS DESIGN AND INSTAUI noN STANDARDS. PIPING.- MAXENf 110•F 90•F ALL INTERIOR PPN INSULATED .L X INSATED WITH CLOSEDCE NSULATION @ MIN.THICKNI.SS). —IFHOSE-OF • TARGET DEPTH FOR BUILDING ENTRY POINT IS 4 F-BELOW GRADE.REFER TO DI AOELIONS DESIGN AND INSTI LIATON 4— MN WATE4 ROW 25 GP4/TON STANDARDS FOR PR)VISIONS WHEN EXCEPTIONS OCCUR. F1 )-1 COXFIN[-MALE. • THE USE OF 04E0E IALVES IS REQUIRED WHEN M LT)PLE HEAT PUMPS ARE CO NECTED TO A COMMON(SHE ED)GROUND REM,LE MAX WATER ROW 33 GP`II/TON LOOP. • SEE SHEETS 2,3,A O 4(OF 4)FOR ADD MONAL Di NDELION SYSTEM REQUREML NTS. ` MN AIR LOW 300 CF'4/TON NEXPANSI(N TANG CONTF ACTOR NAME: PROJECT NAME: PROJECT ADDRESS:57 Olander Dr,Northamr ton,MA DESCRIPTION: I'AGE: Wayne FeidenUSA INTERIOR PIPING(DAND ELION VT) 01)60 DANDELION MUL TI-POSITION VERTIC AL PACKAGED 1 OF 4 VERSI 3N V2021.08 PROJECT I): 21-010-0556 DATE: 3/29/2022 SCALE:NTS SIZE: SO_B_11 X 17 ,Vf HEADER PIPE SIZE PER-\ I — RYI{n�. ��? DESIGN DOCUMENTS M STEF DOWN,STEP-UP No.55865 ,� REVERSE RETURN HEADER SEEP-DOWN,STEP-UP A //REVERSE-RETURN HEAL ER f°A.,- IINAL EMb�+t./` VERTICAL BOREHOLE(QTY AN) / (PER D&I STANDARDS) S'ACING PER DESIGN DOCUMENT) 111 11E111111111E_ J4j , -OUGH GF ADE 'III \\ \\ \ \ �11. .=��/� \ 'I.,�' NDI!TUBBED SOIL 11 _ A _ =11. � ii =u. :I1 a��\\��\\��\y�\\ Ic-1 CALCUL/ TED 4 FT. , If-� \\ \\/\\/\ 1'Il I = ILL DEFT I ....111��������� ,,4Li — \ \ \ \ 11-1 APPR)X. 6 IN. GRANULAR BACK 1LL 1 �1t , -w•r„f.• i./1I (NO LOCKS OR LARGE CHUNKS) II ]INIli -C,4-•r`~.`r;.••.E air ISENIHEADER PIE INL DETAIL HEADER PIPE SIZE i v PER DESIGN DOCUMENTS \ TRENCHING N LIES: LIX P SUPPLY LOOP RETI RN `U-BEND QTY AND PIE-SIZE BWHEN SITE I ONDEoNS DO NOT ALLOW EXCAVATION TO THE REM RED 4 FT. DEPTH (FRO A BUILDING) (TO BUILDI IG) C-C SPACING P:R PER DESIGN DOCUM'NTS INSULATE TH_ HEADER PIPING WMTH R11 r INSULATION (MUST BE RI TED FOR DIRECT BURIAL). DESIGN DOCUMEE TS INSTALL THE NSULATON DIRECTLY ABO`E AND ALONG THE CUTER =DGES OF THE PIPING AT GROUND LOOP I aYOIfT gFTAN THE BOTTOM OF THE TRENCH FOR FRE 2E PROTECTION. HEADER PIPING DETAIL ,;ENERAL NOTES- SYSTEM ANTIFRE 2E MUST MEET OR EXCEED At I BUILDING CODES • ALL UNDERGROUND PPE FITTINGS/CONNECTION:; MADE VIA HEAT FUSION PER ANSI/CSA/IGSHPA C 148.0-16, SECTION 5.4.2 CORRESPOND WITH FREEZE POINT 12-13°Fa_.0W MIN EWT • ALL GROUND LOOP P PING HDPE, MIN. 160 PSG RATING (PE 3608 OR 4'10, DR11) PER ANSI/CS I/IGSHPA C448.0-16, SE:DON 5.4.2 ANTIFREEZE CONCENTRATION%BY%OLUME • MINIMUM BORE SPACIIIG AND CALCULATED BORE DEPTH PER LOOPUNK f LC - • MIN. SEPARATION DIM ONCE FROM ALL STRUCTURES AND UTILITIES (FOUN)ATION, GAS, SEWER, SEE TIC, PROPERTY LINES, ETI:.) IS 10 FT., MIN EWT°F) UNLESS OTHERWISE S'ECIF'IED BY THE AHJ. ANTIFREEZE TYPE 25°F 30°F 3i°F-45°F >45°F . INSTALL R2 (MIN.) PIPE INSULATION ON HEADEI' PIPING WHEN CROSSING A WATER/SEWER UNE • FULL LENGTH GROUT!!IG REQUIRED, 1.20 BTU/I IR-FT-F GROUT THERMAL CONDUCTIVITY VALUE PROPYLENE GLYCOL 28% 22% 20% 0% • HEADER PIPING MUST BE LAID OUT IN REVERSE-RETURN FASHION AS IN NCATED IN THE HEADER IETANL DRAWING. ETHANOL 25% 20% 15% 0% • ALTERNATIVE PIPING L.WOUT/DESIGN MUST BE 'RE-APPROVED BY DANDF UON. • SEE SHEETS 1, 3, M D 4 (OF 4) FOR ADDTTIO SAL DANDELION SYSTEM F EQUIREMENTS. METHANOL IX/NOT USE SS% 10% OK • PRIOR TO STARTUP, i-1E GROUND LOOP SHALL BE FLUSHED AT 2 FPS-0 REMOVE AIR/DEBRIS U LNG A 1.5 HP PURGE PUMP HEAT TRANSFER FLU D MUST COMPLY WITH ANSI/r SA/IGSHPA C4480-16, SECTION 5.7 CONTF ACTOR NAME: PROJECT F AME: PROJECT ADDRESS: 57 O18ndeT Or,Northam ton,MA DESCRIPTION: P E: DANDELION Wayne Feiden 01)60,USA GRCUND LOOP AND HEADER PIPING 2 OF 4 VERSI A V2021.08 PROJECT II l: 21-010-0556 DATE: 9/2022 SCALE:NTS SIZE:180_13_11 X 17 COL)WATER S JPPLY O 1111,111111, _`tNOfaM,„,'"' HEAT PUMP WATER HEATER SPECIFICATIONS `a+• ,� 56� VOLTAGE/PHASEhR UPPER/LOWER ELEMENT WATTAGE MAX WATTAGE REQUIRED BREAKER SIZESUPPLY(TO HOT WATER ELECTRICAL 23011/60 4600 4500 30AMP HOUSE) 'It GAM PERFORMANCE NOMINAL CAPACITY(GAL) RATED STORAGE VOLUME(82) UEF FIRST HOUR RATING(GAL) z"% No.SA5 i'"- RATINGS 80 82 3.46 86 HOT WATT R (OUTLET) • . • 7—COLD WATER (INL • MWATEW)HEAT PLW P I ER IEATEf ,. 0 TEMPO ATURE AND PRESSURE J 0 RELIEF VALVE (TPV) • DRAW CONDENSATE T,I APPROVED DRA N PER AFU LEGEND FML.VALVENMNUAL L -S {] DRA V VALVE-MANUAL NOTE:- — ��YY H IT WATER LINE • DOMESTIC HOT WATER CON EC nONS SHALL MEET OR EXCEE 7 ALL APPLICABLE BUILDING C DOES. CC LD WATER LNE • TI MPERATURE AND PRESSURE 7HEF VALVE(TPV)SHALL BE FACTORY INSTALLED AND TI FA1WAT D ACCORDING TO A PUCABLE BUILDING CODES -♦ P PING,TUBING, • Al L NEW PLUMBING 61 IN.(MN.)PEX OR COPPER 4— I-XE{)EIERAL • TIE NEW WATER HEATER SHALT TIE-INTO THE EXISTING DOMF STIC WATER PLUMBING. • SIE SHEETS 1,2.AND 4(OF 4)P IR ADDITIONAL DANDELION SI STEM REQUIREMENTS. CONTI ACTOR NAME: PROJECT 1 AME: PROJECT ADDRESS: DESCRIPTION: PAGE: Wayne Feiden 57 Olander Dr,NorthamF ton,MA HEA r PUMP WATER HEA[ER SILL MODELS) 3 OF 4 DANDELION 01)60,USA INSI ALLATION DETAILS( VERS ON V2021.08 PROJECT 1): 21-010-0556 DATE.3/29/2022 SCALE:NTS SIZE: SO_B_11 X 17 k (NEW)I EAT PUMP ELECTRICAL PANE. Mll REFER TO TABLE FOR BREAKER RED KREMENTS • aECTRICAL WORK MUST NEE,OR EXCEED ALL APPLICABLE (EV TNO)MAIN ELE:TRICAL PAAEL BODING 8 ELECTRICAL.CODES • WREN THE INSTANCE FROM THE BERME PANEL TO THE HE,T PUMP L ,rr, ,r,rrrrr�� IS GREATER THAN 100 FT,CONSULT WrTH THE ENGINEERING TEAM "�1N Of Y4_ FOR FURTHER REVIEW. -EAT PUMP \tT: ^'_.,, '% • 9EE SHEETS 1,2,AND 3(OF 4),DR ADDITIONAL DANDELION I YSTEM L �O \G� REQUIREMENTS. 47 RYAN J. 40 — ___ - - - -0 of CARDS ;_'_ =u No.55865 / c L AUX REALER 'i JtroSAI F.'66`�,,` L (0) \ R MI■ \ o Mil MIN�■ Y HEAT PUMP ■fr7 ■fib ma■ ‘('', (0) 0 / — Do oll W1 ECOBEE HERMOSTAT(NEN) ::OM)8/ISATE PuMP 3REAK(C)WIRE IF CONDENSA(E SACKS UP OR MALFUNCTIONS HEAT PUMP ELECTRICAL SPECIFICATIONS AUX HEAT ELECTRICAL SPECIFICATIONS(WHEN APPLICABLE) VOLTAGE/ LRA WI SOFT VOLTAGE! AUX HEAT KW AUX HEAT AUX HEAT 4100EL PHASEHZ FLA(AMP) LRA AI START(A) MCA(A) MOP(Ai MODEL PHASEMZ (240V) AMPS 240V( AUX HEAT MCA(A) MOP V1-024 230/1,60 209 58.3 175 23.8 35 V1-024 230/1/60 5 20.8 260 30 YU036 230/1/60 248 83.0 249 28.7 40 YT-036 230/1/60 10 41.7 521 60 Y1-048 230/1/60 319 1040 312 372 50 YT-048 230/1/60 10 41.7 52.1 60 51-060 2301/60 395 152.9 45.9 46.3 70 VT•060 23011/60 10 41.7 521 60 Y1-072 230/1/60 421 1729 536 49.5 70 VT-072 230/1/60 10 41.7 521 50 CONTF ACTOR NAME: PROJECT t LAME PROJECT ADDRESS: DESCRIPTION: 1 SAGE: Wayne Fefden 57 Olander Dr,Northam'ton,MA ELECTRICAL/THERMOST/.T/CONDENSATE DANDELION 01360,USA PUMP WIRING(DANDELIC N VT) 4 OF 4 MUL-I-POSITION VERTIC/.L PACKAGED VERS ON V2021.08 PROJECT I): 21-010-0556 DATE: 3/29/2022 SCALE:NTS SIZE: SO_B_11 X 17 GSHP Design Report Project: Wayne Feiden 21-010-0556 (Project ID:28547) Prepared: 29-Mar-2022 Prepared By: Ameed Azar by ceocojl xis Inc Equipment Schedule Based on the provided loads, the recommended heat pump schedule for this system is as follows: High Cap. Low Can. 1 kBtu/hr= 1,000 Btu/hr I I I Cool ' I Water 21 Air 3 I Cap. Cap. Flow Flow QTY (kBtu/hr) (kBtu/hr) (GPM) (CFM Dandelion Energy- Enertech 30.90 39.40 9.0 1,420 Whole house Multi-Position Vertical YT-036 1 24.50 31.53 High Capacity Totals 30.90 39.40 9.0 Low Capacity Tot. ' 24.50 31.53 - 1. All capacities shown are total. 2. When applicable,hydronic source and load water flows are assumed equal. 3. Air flow rates are reported on a per heat pump basis. For total air flow In a zone,multiply the reported air flow by quantity. 2 of 7 , New York Equipment Efficiencies The following efficiencies are for air systems, hot water generation efficiencies can be found on the hot water generation page. NOTE: GSHP efficiencies shown below are system wide averages which include pumping and applicable resistance energy. Efficiencies for individual GSHP zones can be found on the zone pages. Heating Cooling GSHP (COPAVG) 4.02 GSHP (EERAVG) 17.65 Electric Resistance (COPH) 1.00 A/C (SEER) 15.00 ASHP (HSPF) 6.00 ASHP (SEER) 15.00 Natural Gas (AFUE) 88.00% Old GSHP (EER) 10.00 Propane (AFUE) 90.00% Fuel Oil (AFUE) 80.00% Old GSHP (COP) 2.80 3 of 7 , New York Whole house Zone Details The peak loads for each Individual zone are used to calculate the total amount of heating & cooling capacity required for a space based on the set points and the climate data for your area. Peak Heating Load 30,086 Btu/hr Peak Cooling Load 16,820 Btu/hr Heating Set Point 72°F Cooling Set Point 72°F Heating Offset 0 Btu/hr Space SHF 0.823 GSHP Selection The ground source heat pump below has been selected to maintain comfortable heat- ing & cooling for this zone. Manufacturer Dandelion Energy Model Enertech Multi-Position Vertical YT-036 Heat Pump Type Water to Air Capacity Dual Capacity # Heat Pumps 1 lnctailart (:anarity (:hark The installed capacity check describes the efficiency and total heating/cooling capacity of the selected ground source heat pump system. This information is used to ensure proper sizing of equipment based on the load represented by this zone. Heating (High Capacity) Cooling (High Capacity) Heating Capacity 30,900 Btu/hr Total Cooling Capacity 39,400 Btu/hr % Sizing 102.7% Sensible Cooling Capacity 29,550 Btu/hr % Energy From Geo 99.9% % Oversizing 113.5% Installed COP 4.12 Installed EER 15.33 Balance Point Temp. -1.2°F Heating (Low Capacity) Cooling (Low Capacity) Heating Capacity 24,500 Btu/hr Total Cooling Capacity 31,530 Btu/hr % Sizing 81.4% Sensible Cooling Capacity 23,647 Btu/hr Installed COP 4.43 % Oversizing 70.8% Installed EER 23.50 4 of 7 , New York Whole house Zone Operating Summary The Zone Operating Summary describes equipment runtime and the total annual power consumption for the GSHP operating in this zone. Heating Cooling High Capacity Runtime 256 hrs High Capacity Runtime 0 hrs Low Capacity Runtime 2,124 hrs Low Capacity Runtime 537 hrs Supplemental Bin Hours 32 hrs Dual Fuel Bin Hours 0 hrs Heat Pump Energy Use 4,015 kWh Heat Pump Energy Use 794 kWh Pumping Energy Use 312 kWh Pumping Energy Use 70 kWh Supplemental Energy Use 21 kWh Dual Fuel Energy Use 0 kWh GSHP Operating Cost Breakdown for Zone Name Based on the annual power consumption of the system and the price per kilowatt hour in your area the estimated cost to maintain the set points for this zone are as follows: Heating Cooling HP Cos $963.65 r it :.ust $190.59 Supplemental Cos $5.07 Pumping Cost $16.92 Dual Fuel Cos $0.00 Total Cost $207.51 Pumping Cos, $74.97 Total Cos` $1,043.69 411111k I u 77.0% HP Heating Ccat I 16.0% Pumping Cost-Heating r MIN 0.4% Supplemental Heating Cost INN 15.2% HP Cooling Cost I I 1.4% Pumping Cost-Cooling 5 of 7 , New York Back-Up System Details Supplemental System Details Supplemental systems operate at the same time as the geothermal heat pump and provide additional heat when the space load is greater than the system capacity. Supplemental System Type Electric Resistance C 1.0 Zone Load and Operating Profile 900 54 800 48 700 42 i r 600 36- 500 30Q 00 24 a = 300 1C-o Q 'G 200 12 ' 100milftnI , Not6 fl 0 0 n 2 r1 c ' ° N ry n m n a a 2 2 m n a> 2 2 a $ 1 1 I � Temperature(°F) - Heating Load - Low Capacity Heating Operation • High Capacity Heating Operatioh - Cooling Load - Low Capacity Cooling Operation •• High Capacity Cooling Operation I Supplemental Heating I GSHP Heating I GSHP Cooling Heating Cooling Heating Start OAT 57.0 °F —Ailing Start OA 65.0 °F High Capacity Runtime 256 hr High Capacity Runtim 0 hr Low Capacity Runtime 2,124 hr Low Capacity Runtime 537 hr Supplemental Bin Hours 32 hr 6 of 7 i , New York Vertical Bore 15 ft cc Earth Temperature Data Location Deep earth (below 20ft) temperature is a function of the average annual air tempera- ture in your region and remains relatively constant regardless of season. Deep Earth Temp (Tc) R1 n °F Formation Details The thermal properties of your formation are based on the formation's composition and have a direct impact on the scale of your loopfield. i hermai L.onauctivity 1.41 Btu/hr ft °F GHEX Summary Heating is dominant. Grout is used inside of all bores in order to protect the deep earth environment from surface contaminants and to provide a more effective contact surface with GHEX piping that optimizes heat transfer between the fluid pumped through your GSHP and the earth. Grade _ Grout T.C. 1.20 Btu/hr ft°F I i sage 1 -- .;`; EWTMIN 30.0 °F LI Formation _ _ • EWTM, 90.0 °F Q Granular Badcfdl :-:-.1 ::-:::: ) ..* C Grout ______-_ _-`=_ _=� J '' I Bore Diameter(DO 5.00 in ==_= _ GHEX Pipe 1.25"DRII.OHDPE4710 nr (4 max.) _-_- 1 2 ... I Bores in Series (NBIS) 1 0 =_'= __- _= Le Layout Rows (n,°,$) 1 a SB�re S __- Bores per Row 1 m 2 Q 0 ri-r�- __ __= Number of Bores 1 ii m SB ===: _ Bore Spacing (SB) 15.0 ft ° 3 .. TOP VIEW DETAIL Design Depth (LB) 359 ft (GENERIC) (GENERIC) Header Pipe 1.50'na+1.o HDPE 4710 7of7 I , New York Vertical Bore 18 ft cc Earth Temperature Data Location Deep earth (below 20ft) temperature is a function of the average annual air tempera- ture in your region and remains relatively constant regardless of season. Deep Earth Temp (Tc) 53 n °F Formation Details The thermal properties of your formation are based on the formation's composition and have a direct impact on the scale of your loopfield. Thermal Conductivity 1.41 Btu/hr ft °F GHEX Summary Heating is dominant. Grout is used inside of all bores in order to protect the deep earth environment from surface contaminants and to provide a more effective contact surface with GHEX piping that optimizes heat transfer between the fluid pumped through your GSHP and the earth. Grade Grout T.C. 1.20 Btu/hr ft°F - °EWTMIN 30.0 F F] Barkfill '0 Formation = EWTMAX 90.0 °F Granular Badcfill = - f Grout ___- - -__-_ Bore Diameter(DB) 5.00 in GHEX Pipe 1.25•DR11 OHDPE471O n (4 max.) 7-:- ..":::: 7:: --_-1---_ .1.! iI 1 21 ... - .-_. __ ____ I Bores in Series(NBIs) 1 1 ® ® __ _ Ls Layout Rows(n, ) 1 o 1—Si--.1 ___ = Bores per Row 1 m 2 ® 0 T :._ -- Number of Bores 1 m0. Ss _ __ V__,= Bore Spacing (Se) 18.0 ft m° 3.-0 0i TOP VIEW DETAIL Design Depth (LB) 359 ft (GENERIC) (GENERIC) Header Pipe 1 so-na 11.0 HOPE 4710 8of7 I ,New York wrightsoftDate: Building Analysis Job: 21-0104556 Entire House By Dandelion Energy 333 N h Bedford Road,Suite 220,Mart Kisco,NY 10549 P1ore:833-GE0-4ALL Email:desgnada deliorerergymm Web:emwdardeliorerergycom Pro-act Information For Wayne Feiden 57 Olender Dr.Northampton.MA 01060 Design Conditions Location: Indoor. Heating Cooling Westover Metro,MA,US Indoor temperature(°F) 72 72 Elevation: 241 ft Design TD(°F) 66 16 L.autuae: 42 AN Kelm ve numioity(%) SU aU Outdoor. Heating Cooling Moisture difference(grAb) 29.3 312 Dry bulb(°F) 6 88 Infiltration: Daily ra (°F)ge( - 72 ( M ) Method Construction quality Semi-tight ified Wet bulb - Wind speed(mph) 15.0 7.5 Fireplaces 1 (Semi-tight) Heatin• Component BtuM Btuh %of load Walls 5.4 9630 32.0 ventilation Glazing 21.1 4760 15.8 1 ' Doors 25.9 1088 3.6 walls Ceilings 2.1 2363 7.9 Floors 1.1 1257 42 Infiltration 3.7 6990 232 nilltration Ducts 1826 6.1 Piping 0 0 Humidification 0 0 ill' . . Ventilation 2172 7.2 Adjustments 0 Glazing Floors ivtai I I JUUO0 I i1lU.IJ I ��w° caa„o.Q Coolin• Component BtuhAt2 Btuh %of load Walls 1.3 2407 17A ventilation (ria,inr, 19.7 A441 32.1 walls\ Doors 102 427 3.1 memai wins Ceilings 1.6 1764 12.7 IF Floors 02 278 2.0 Infiltration OA 757 5.5 Ducts 567 4.1 Ventilation 514 3.7 infiltration Internal gains 2690 19.4 Glazing Floors Blower 0 0 I Adojustments I tal 13844I 100.0 Doors Ceilings Latent Cooling Load=2976 Btuh Overall U-value=0.072 Bluhl112-°F Data entries checked. - wrightsoft- 2022-Mar-29 13:56:47 ^- .-° ^''—, RIgH-Stfls®Urf ersal202121.0.08 RSU28723 Page 1 _.peg 1-010-0556 W ayre Feideni Heat Loadnp Caic=MJ8 Frort Door tsces W wrightsoftte Building Analysis JQab. 21410,0556 1st Floor By. Dandelion Energy 333 Nat Bedford Road,Stile 220,Mart Kisco,NY 10549 Phone:833-GEO-4ALL Email:deagrC@dardeliorerergyoom Web:wwwcdardeiorerergy corn Pro'ect Information For. Wayne Feiden 57 Olander Dr,Northampton.MA 01060 Desi•n Conditions Location: Indoor. Heating Cooling Westover Metro,MA,US Indoor temperature(°F) 72 72 Elevation: 241 ft Design TD(°F) 66 16 L.atkuoe: 4L"N Negative numIaily t%) su 5u Outdoor. Heating Cooling Moisture difference(grllb) 29.3 312 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 1 (Semi-tight) Heatin• Component Btuh/Tt Btuh %of load Walls 62 5594 32.8 I cis Glazing 23.3 3340 19.6 Doors 25.9 1088 6.4 W°lle Ceilings 2.1 725 4.3jp. Floors 1.0 1049 6.2 filtration Infiltration 3.7 3418 20.1 Duds 1826 10.7 Piping 0 04\ Humidification 0 0 Floors Ventilation 0 0 Adjustments 0 Gladly rIneWS Cabs IOIsit I I i i iri r I 100J0 I Coolin• Component Btuhlft2 Btuh %of load Walls 1.5 1377 14.6 (:laiinn 9C el17Qn An 1 Walls\ Internal Gains Doors V 10.2 427 4.5 Ceilings 1.6 541 5.8 Floors 0.2 248 2.6 Infiltration 0.4 370 3.9 uds Duds 652 6.9 Ventilation 0 0 Infiltration Internal gains 2000 21.3 Floors Blower 0 0 Glazing Adjustments I I Total 94050 I 100.0 I Doors Latent Cooling Load=1271 Btuh Overall U-value=0.079 Btuh/f12--°F Data entries checked. -+ - wrightsoft 2022-Mar-29 13:56:47 .4C I gNSUts®Urioersal202121.0.08RSU28723 Page 2 _.DeeigrN21-010-0556 Wayne Feidenl Heat Load r p Caic=MJS Frorl Door Laces W Building Analysis Job:. 21-010-0556 wrightsoft 2nd Floor By. uanaeiion Energy 333 North Bedford Road,Sr11e 220,Mout K1sa,NY 10549 Phors:833-(;EO-4/LLL En iI:derigredeniefiorenergycom Web:wonsdendeiwenergymm Pro-act Information For. Wayne Feiden 57 Olander Dr.Northampton.MA 01060 Design Conditions Location: Indoor. Heating Cooling Westover Metro,MA,US Indoor temperature(°F) 72 72 Elevation: 241 ft Design TD(°F) 66 16 Lamle: 4L'I4 Keiauve numlany(%) ,so au Outdoor. Heating Cooling Moisture difference(gnlb) 29.3 312 Dry bulb(°F) 6 88 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 1 (Semi-tight) Heati n• Component Btuhlft2 Btuh %of load Walls 4.5 4035 37.1 Glazing 17.3 1420 13.1 Doors 0 0 0 ,,,, Ceilings 2.1 1638 15.1 W� Floors 52 208 1.9 Infiltration 3.7 3572 32.8 Duds 0 0 Piping 0 0 Humidification 0 0Ven oapr Adjustments on 00 0 Glavin/ Celfirrga wuti I I iuoiq i iuu.6 1 Coolin• Component Bluh/f 2 Btuh %of load Walls 12 1030 18.1 Internal Gains rtla7inre 28.3 7197 do CI Walls, Doors 0 0 0 Inflltraflon Ceilings 1.6 1222 21.5 Other Floors 0.7 30 0.5 Infiltration 0A 387 6.8 Duds 0 0 Ventilation 0 0 Ceilings Internal gains 690 12.1 Blower 0 0 Adjustments 0 "i "'y Total I 5686 I 100.0 I Latent Cooling Load=1075 Btuh Overall U-value=0.062 Btuh/ftz-°F Data entries checked. wrightsoft. 2022-Mar-29 13:56:47 "" •r ". _ -.-.„" "• ,�,., RigIt-Stfle®UritiersaI202121.0.08RSU28723 Page 3 AC .Desigril21-010-0556 Wayne Feider4 Heat Loadnq C:aic=MJ8 Fmrt Door faces W -4+ wrightsoft Right-J8® Form J1 Job: 21.010-0556 Entire House Date: By IJalnuaiiuti Eti43iluy 333 Nor i Bedford Road,SUM 220,Mout Kfew,NV 10549 More:833-GE0-4ALL Email:desgr@dardelbrerergyc n Web:wwrrdardeiorenergy com 1 Name c4Room Erin)House 1st Roor 2 Running Feeto4Exposed Wall 258D ft 136A R 3 Ceiling Ht(R)and Gross Wall Area(SgR) 8.0 R 2197D ft' 8.0 ft 1221A fr 4 Room Dimensions(R)and Roor Ran Area(SqR) 18429 tr 10720 ft 5 Ceding Slcpe(Deg.)and GmssCeding Area(SgFt) 0 ° 1842.8 If 0 ° 1072-0 ft' Type of Cons., Panel HTM Area or Ruh Area or BUh Exposure Number Faces Length Lengfl Htg. Clg. Healing S-Clg L-Clg Healing S-Clg L-Clg 6 el., 12E-0av n 452 1.15 564 2214 565 268 967 247 F—Glaz 1D-2avd n 37.85 19.65 42 1590 825 42 1590 625 az 2 glazing,dr outr, n 1726 8.86 32 548 281 32 548 281 V e l 12E-0a v e 452 1.15 314 1299 332 102 461 118 11 ez 2 glazing,dr out, a 1726 27.55 26 453 723 0 0 0 vySI 1'Lt4/ew S 4.5L 1.M 5tf4 LL4L 5/L Lan 114tl a Li t—aez 2 glazing,dr out, s 1726 14.96 68 1166 1011 34 584 506 all 12E-0sw w 452 1.15 468 1756 448 256 899 230 az 2 glazing dr outr, w 1726 27.55 58 1003 1601 36 619 988 Door 11D0 w 25.90 10.16 21 544 213 21 544 213 ttli_Door 12A-0sw - 15.94 3.68 154 2119 490 154 2119 490 11D0 n 2590 10.16 21 544 213 21 544 213 Cell 16B-30ad - 2.12 159 1112 2363 1764 341 725 541 Ror 19C-30besp - 0.98 023 1072 1049 248 1072 1049 248 Ror 20P-11w - 5.18 0.74 40 208 30 0 0 0 htiitrabn Heeling Load(Ruh) 0.33 6990 3418 Elect WAR WAR 12 Sensible Load(Btuh) ACH 1A0 757 1.00 370 0.18 LO ItL�rLs..�1) I I .x. 't t hternal a Omrpants at 230 and 200 BUh 3 690 800 0 0 0 b Scenario number 2000 2000 13 c Default Adjustments d Custom Appliances 0 0 0 0 e Rants 0 0 14 Subbhls Sum Iines6through 12 26088 12764 1529 15215 8754 454 F'-MF&ESl3F I nrrnl nn7R 1a'K: r.07 1R'If: PR') 15 Loads r r ELG 816 816 16 Vertlation Loads Vent Cfm 60 E Urn 60 2172 514 830 0 0 0 17 Wirier HumIckl®6onLoad GalADay 0 0 0 18 Piping Load 0 0 19 Stover Heat 0 0 20 AED Bunion&Lsia 1 Mxstjre f 4gratlon Load 0 1190 21 Total Load Sum lines 13 through 19 30066 13844 2976 17041 9405 1271 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Ala- wragptitsoft- 2022-Mar-29 13:56:47 AC-� ----- Rght-S4.1106LkiversaI202121.0.06RSU28723 Pagel _.Daelgrk21-010-0556 Wayne Feideni Heat Loadno Caic=MJ8 Frort Door toes:W +{+ wrightsoft Right-J8® Form J1 Job: 21-010-0558 Entire House Date: BY ComivaiiuII C11Kf9y 333 Nortr Bedford Road,Stile 220,Mout Kisco,NY 10549 Phone:833-GE0.4ALL Erreil:desigr@dadeliorerer9lr om Web:wmwdarcieforerergy.00m 1 Name of Room 2nd Floor 2 Runring Feet of Exposed Wail 122D It 3 Ceding It(R)end Gross Wall Area(SgFt) 8.0 It 976.0 1F 4 Room Dimensions(Ft)and Floor Plan Area(SqR) 770E IF 5 Ceding Slope(Deg.)and Gross Ceiling Area(SqR) 0 ° 710E IF r Type of Const, Panel HTM Area or Bbih Area or Btrh Exposure Number Faces Length Lengl1 Hti. Clg. Healing S-Clg L-CIg Hewing S-Cig L-Clg 8 V�all 12E-09w n 4.52 1.15 276 1246 318 �{yaz 1D-2ood n 37.85 19.65 0 0 0 az 2 glazing,dr outr, n 1726 8.86 0 0 0 all 12E-0aw e 4.52 1.15 212 839 214 11 az 2 glazing,dr outr, e 1726 2755 26 453 723 Wall 1Z -UaN 8 4.bZ 1.1b L/b 1094 ZR I Gaz 2glazing droutr, s 1726 14.96 34 583 505 V�all 12E-Oaw w 4.52 1.15 212 857 219 I4--c_�az 2 pplIating.,dret, w 1726 27.55 22 384 613 Door 11b0 w 25.90 10.16 0 0 0 aIW I 12A-0sw - 15.94 3.68 0 0 0 �-�oor 1100 n 2520 10.16 0 0 0 Cell 16B-30ad - 2.12 1.59 771 1638 1222 Ror 19C-30be p - 098 023 0 0 0 Ror 20P-11w - 5.18 0.74 40 208 30 titltraton Heating Load(Ruh) 0.39 3572 Efed WAR 12 Sensible Load(Btuh) ACH 1.00 387 0.18 . ,ual I:C.111 I ••,,, Hears] a Occupants et230 and 200Ruh 3 690 600 b Scenario cumber 0 13 c Default Adjt iients d Cusbm Appliances 0 0 e Plants 0 14 Subtotals Sum lines trough 12 10674 5686 1075 m„+ Fir.FSFSGF I ni n n n 15 Loads II IELG 0 16 Verddation Loads Vent Cfm 60 E Cfm 60 0 0 0 17 Writer Humidification Load GaWay 0 0 18 Piping Load 0 19 Blowar Heat 0 20 AED Emission&Latent Moisture Migration Load 486 21 Todal Load Sum lines 13 thnxlgh 19 10874 5688 1075 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -4 1- wrfutsttsoft- 2022-Mar-29 13:56:47 Riga-Stile®Lkiversel 2021 21.0.08 RSU28723 Page 2 _.Deeigrr(21-010-0556 Wane Feideni Fleet Load no Calc=MJB Fort Door faces:W +`+ wrightsoft Right-J8® Form J1 Job: 21-0104556 1st Floor Date: By. DJd114JtliWlt CIIUI9y 333 Norte Bedford Road,Slice 220,Mout Kieoo,NY 10549 Ptore:frt't-CEO-4ALL Entail:deegr@dardeliorenergycom Web:Mwwdardeforsrergy.com 1 Name of Room 1atRoar Room2 2 Running Feet of Exposed Wall 136D ft 136D t 3 Ceiling Ht(R)and Gross Wall Area(SqR) 8D t 1221.0 ft: 8D ft 1221.0 fF 4 Room Dimensions(R)and Roor Plan Area(SqR) 1072D fF 1 D x 10720 t 1072.0 t= 5 Ceding Slope(Deg.)and Gross Ceiling Area(SqR) 0 ° 1072D IF 0 • 10720 fg Type of Const, Panel HIM Area or Ruh Area or Bluh Exposure Number Faces H� CIg. Length Hating S-Clg L-Clg Heeling SCIg L-GIg 6 1. all 12EOew n 452 1.15 288 967 247 288 967 247 . az 1D 2ovd n 37.85 19.85 42 1590 825 42 1590 825 ll daz 2 glazing,dr out, n 1726 8.86 32 548 281 32 548 281 Wall 12E-0av a 4.52 1.15 102 461 118 102 461 118 11 az 2 glazing,dr out, e 0.00 0.00 0 0 0 0 0 0 tri lLt4law S 4JL 1.1, Lt115 1141 L�JJ AZ 114t1 L`J3 t aaz 2 glazing,dr out, s 1726 14.96 34 584 506 34 584 506 all 12E-0aw w 452 1.15 256 899 230 256 899 230 az 2 glazing,d r out, w 1726 2755 36 619 988 36 619 988 1100 w 25.90 10.16 21 544 213 21 544 213 Wall 12A-0ga - 1594 3.68 154 2119 490 154 2119 490 Door 11D0 n 25.90 10.16 21 544 213 21 544 213 Cet 1613-30ad - 212 1.59 341 725 541 341 725 541 Ror 19C-30bavp - 098 023 1072 1049 248 1072 1049 248 Ror 20P-11w - 0.00 0.00 0 0 0 0 0 0 htllre/on Heating Load(Binh) 0.33 3418 3418 Elect WAR WAR 12 Send*LDed(Btuh) ACH 1.00 370 1.00 370 0.15 Leiait Load(Bil) I l :+- Internal a Occupants at 230 and 200 Bluh 0 0 0 0 0 0 b Scenario number 2000 2000 13 c DefaultAdjuslrnetis d Cusbrn Appliances 0 0 0 0 e Plants 0 0 14 Subtotals Sum lines through 12 15215 8754 454 15215 8754 ^,•a EHLF&F'Se I n.ml nmx 1r>a SC' IQ, RA') 15 Loads r r ELG 816 816 16 Ventilation Loads Vent Cfm 35 E Cfm 35 0 0 0 17 WIAerHumidttaion Load Gainey 0 0 18 Piping Load 0 19 Bower Heat 0 20 AED Exwsbn&Lalsrt Moitlire Mgraion Load 1190 1190 21 Trial Load Sum lines 13 Trough 19 17041 9405 1271 17041 9405 Calwlations approved byACCA to meet all requirements of Manual J 8th Ed. wrfpFst tt- 2022 r-2913:56:47 ---- RigitSJte®Uriverse12021 21.0.08 RSU28723 Page 3 _.Dee;grNl21-010-0556 Wayne Feider4 Heel Load sw Calc=M,18 Fiord Door laor W +`+ wrightsoft Right-J8® Form J1 Jab: 21-01043556 2nd Floor Date. By: 1JatititUiiWtt Etetetgy 333 North Bedford Road,Spite 220,Mart Kisco,NY 10549 Phxe:833-GEO-4ALL Erreil:desgredardeliorerergycom Web:wwwdandeiorerergy mm 1 Name of Room 2nd Roor Room4 2 Running Feet of Exposed Wall 122D ft 1220 t 3 Ceiling Ht(R)and GrosWail Area(SgR) 8.0 It 976D 1F 8D ft 976.0 tf 4 Room Dimensions(R)and Roar Plan Area(SqR) 770.8 fr 1.0 x770.8 ft 770.8 ff 5 Ceiling Slope(Deg.)and Gross Cal ing Area(SqR) 0 ° 770.8 IF 0 ° 770.8 R Type of Cont., Panel HIM Area or Ruh Area or BVh Exposure Number Facss Length Length Htg. Clg. Fleatng S-Clg L-Clg Healing S-Cig L-Clg 6 all 12E-Osv n 4.52 1.15 276 1246 318 276 1246 318 az 1D-c2ood n 0.00 0.00 0 0 0 0 0 0 az 2 glazing,dr outr, n 0.00 0.00 0 0 0 0 0 0 Wall 12E-0aw a 4.52 1.15 212 839 214 212 839 214 11 Glaz 2 glazing,dr out, a 1726 27.55 26 453 723 26 453 723 Waif 12t-U,9+Y s 4.5Z1.1� L/b 11Ri4 LI' 2/li 1t L/y f paz 2glazing droutr, s 1726 1496 34 583 505 34 583 505 a 0000r 12E-0sw w 4.52 1.15 212 857 219 212 857 219 az 2 glazing,dr outr, w 1726 27.55 22 384 613 22 384 613 11D0 w 01)0 0.00 0 0 0 0 0 0 Wall 12A-0sw - 0D0 0.00 0 0 0 0 0 0 Door 11 D0 n 0D0 0.00 0 0 0 0 0 0 Ceil 1613-30ed - 2.12 1.59 771 1638 1222 771 1638 1222 Ror 19C-30t p - 0D0 0.00 0 0 0 0 0 0 Flor 20P-11w - 5.18 0.74 40 208 30 40 208 30 Infiltration Healing Load(Ruh) 0.48 3572 3572 Effect WAR WAR 12 Seneble Load(Bdlh) ACH 1.00 387 1.00 387 022 Laaht Load(Tiiu I "� Internal a Occupants at 230 and 200 B►rh 3 690 600 3 690 600 b Scenario number 0 0 13 c Default Adjustments d Cusbm Appliances 0 0 0 0 e Plants 0 0 14 Subtdals Sum lines 6through 12 10674 5686 1075 10874 5686 cur F&ES(F I nI n n n n n 15 Loads r ELG 0 0 16 Ventilation Loads Vent Cfn 25 E Cfm 25 0 0 0 17 Winter Hunidit®ton Load GaliDay 0 0 18 Piping Load 0 19 Bloaer Heat 0 20 AED Eiarsbn&Latent Moiskire Mgration Load 486 486 21 Total L ced Sun lines 13 through 19 10874 5686 1075 10874 5686 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wr/-tit .. .... 2022 Mar-2913:56:47 " "_ ^"' Rigl-Srite®LMversa1202121.0.08RSU28723 Dadprt(21-010-0556 Wawa Folded Load Celc=MJB Fort Door faces W Page 4 _. N • III II N III II �w Garage d Room2 II e o Job#: 21-010-0556 Performed fo Scale:l :101 r. Dandelion Energy Page 1 Wayne Feiden 333 North Bedford Read Suite 220 RightSuite®Universal 2021 RSU28723 57 Otander Dr ��n 2 iVliiuiili�iyluii,iYAuiVWCO, �1lJ`17 cvcc�rn-ca .i..w.w Phone:833-GEL)-U-4ALl I wwwdandeikx nergycan dasig @danthlionenagycom I ...0556 Wayne Feiden]Heat Load.rup N IP Second Floor Job#: 21-010-0556 Scale:l :101 Performed for Dandelion Energy Page 2 Ware Feiden 333 North Bedford Road,Sine 22p RghtSuite®Universal 2021 57 Olander Dr t Kisco NY 10549 21.0.08 RSU28723 Nuriiwrri�wi,YvwGiG6ii Rhone:833-GE0-4ALL 262c4vm-3 i5.5u.:xi I wwkdandeionenergy.corn dasig. darxblionenergycom I ...0556 Wayne Feiden]Heat Load.nip DANDELION To whom it may concern, Enclosed is the check for the geothermal permit at 57 Olander Dr, Northampton, MA 01060. Please email me a pdf of the permits when it is ready(hkowalski@Dandelioneneray.core). If you cannot email the permits, can you please mail a copy to our office at the address below. Dandelion Permitting Team 333 North Bedford Rd Suite 220 Mount Kisco, NY 10549 Thank you for your help! Hannah Kowalski Permit and it ,Ion Coordinator (860)301-7100 DANDELION 333 North Bedford Road, Suite 220 Mount Kisco, NY 10549 Dandelion Energy Inc. Mail - 57 OLANDER APPLICATION https://mail.google.com/mail/u/0/?ik=9863f38cbf&view=pt&search=a... Hannah Kowalski <hkowalski@dandelionenergy.com> DANDELION 57 OLANDER APPLICATION 2 messages Kim Carson <kcarson©northamptonma.gov> Wed, Apr 6, 2022 at 2:10 PM To: hkowalski@dandelionenergy.com Hi, In order to process your application I will need a check payable to the city of Northampton for $73. Thanks, Kim Carson Northampton Building Department 212 Main St Northampton, MA 01060 413-587-1240 Hannah Kowalski <hkowalski@dandelionenergy.com> Wed, Apr 6, 2022 at 2:15 PM To: Kim Carson <kcarson@northamptonma.gov> Thank you Kim, I will mail that out today [Quoted text hidden] Hannah Kowalski Permit and Inspection Coordinator She/They (860)301-7100 DANDELION 333 North Bedford Road, Suite 220 Mount Kisco, NY 10549 The New York Times I CNN I VOX This Old House I TechCrunch I WSJ 1 of 1 4/6/