24A-116 BP-2022-0180 12 CALVIN TERR COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 24A-1 16-00I CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-0180 PERMISSIONIS HEREBY GRANTED TO: Project# 2022 SOLAR Contractor: License: ' Est. Cost: 84422 VALLEY SOLAR LLC CSL 115680 Const.Class: Exp.Date:04/09/2025 Use Group: Owner: CURTIS,JENNIFER R& ARRON M STEINFELD Lot Size (sq.ft.) Zoning: URA Applicant: VALLEY SOLAR LLC Applicant Address Phone: Insurance: PO BOX 60627 (413)584-8844 376140840101 FLORENCE, MA 01062 ISSUED ON:02/24/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 28 PANEL 11.2 KW ROOF MOUNT SOLAR SYSTEM WITH 2 BATTERIES (19.4 KW) POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Gas: Final: Final: Rough Frame: Rough: Fire Department Driveway Final: Fireplace/Chimney: Final: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: (s • yg . cg''a • Fees Paid: $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner Department use only �_ City of Northampton Status of Permit: Building Department Curb Cut/Driveway Permit I.- y 212 Main Street Sewer/Septic Availability �� i Room 100 f t Water/Well Availability Northampton, MA 01060 c 4 Two Sets of Structural Plans phone 413-587-1240 Fax 187-1272 «4tiot/S0 Plans ?T Fr14n --.. Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, pliSLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1.1 Property Address: /,, 12 Calvin Terrace Northampton MA 01060 Map Lot �fl Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Aaron Steinfield 12 Calvin Terrace Northampton MA 01060 Name(Print) Current Mailing Address: rigor Stetyea Telephone (860)808-8206 Signature 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address: P c,k, h. . ,cract.ea-u- 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from (6) 3. Plumbing Building Permit Fee �7 4. Mechanical (HVAC) l /S 5. Fire Protection 6. Total= (1 +2 + 3+4+5) 84,422.00 Check Number 06 9 This Section For Official Use Only Building Permit Number: ✓r- -34 r1$v DateIssued: T J Ili Signature: � 4•V, �/ Il ? Building Commissioner/Inspector of Buildings 111 Date Ihasbrouck @ northamptonma.gov info�a vallevsolar.solar EMAIL ADDRESS (REQUIRED; CON ACTO ) SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) n Roofing ❑ Or Doors 0 Accessory Bldg. ❑ Demolition ❑ New Signs [O] Decks [Q Siding[0] Other[X solar Brief Description of Proposed Installation of a 28 panel,roof mounted solar system,size 11.200dc kwh and 2 batteries totaling 19.4 Work: Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building :One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Aaron Steinfeld ,as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf, in all matters relative to work authorized by this building permit application. AaroeStei eh' Feb 8,2022 Signature of Owner Date 1, Valley Solar LLC ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Patrick D. Rondeau Print Name Pa d L Rand o_a.u. Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder Patrick D. Rondeau License Number CS-115680 Address Expiration Date l�at �k b- ko-ndLectu, 4/9/2025 Signature Telephone 413-584-8844 9. Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 10/27/22 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No ❑ WYSSLING CONSULTING 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.cor February 2, 2022 Ken Trappen Advanced Solar Solutions 39650 Mallard Bass Lake, CA 93604 Re: Engineering Services Steinfeld Residence 12 Calvin Terrace, Northampton, MA 11.200 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x5 dimensional lumber at 22"on center. Roof Material: Composite Asphalt Shingles Roof Slope: 25, 30 and 32 degrees Attic Access: Accessible Lumber type: Assumed Douglas Fir Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL= 10 PSF • Live Load =20 psf(reducible)—0 psf at locations of solar panels • Ground Snow Load =40 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 117 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 IRC, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent SnapNrack installation manual. If during solar panel installation,the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16" lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 21/2", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16" diameter lag screw with a minimum of 2%"embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 44"on centers. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. V truly yours, ,� Scott E.Wyssli' ., PE MA License No. 505r 4 • E V / N -4,p i imam5 4 y�FF€G s7EP Signed 02-02-22 CON SUNG PARCEL MAP GOVERNING CODES _ DESIGN CRITERIA PROJECT LOCATION GPS COORDINATES(42.333305,72.64923) APPUCABLE BUILDING CODES: BUILDING OCCUPANCY:R-3 I•_ 2015 INTERNATIONAL BUILDING CODE 11J 2015 INTERNATIONAL RESIDENTIAL CODE RISK CATEGORY:II LLJ 2015 INTERNATIONAL FIRE CODE ASCE 7-10 WIND SPEED:117 = J 2020 NATIONAL ELECTRIC CODE EXPOSURE CATEGORY:Exposure C ~ N , SNOW LOAD:40 ¢ (r SNOW EXPOSURE:N/A D. CONSTRUCTION TYPE:VB NORTHAMPTON BIKEWAY O I 4 I f P R. -----1 L� SCOPE OF WORK N ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/ A-�a L. r+ IDRIVEWAY BATTERY STORAGE 0 c a it `� 1 I PROPOSED SOLAR EQUIPMENT SITE/PROJECT DETAILS L.,..o a G I QTY. EQUIPMENT DESCRIPTION/MFG/MODEL CONNECTION UNE-SIDE TAP cc o. I�L1"IT 28 MODULES REC Group REC400AA BLX SYSTEM SIZE DC 11.200 KW - O 1%°''�;;I1 1 R 1 INVERTER(5) SolarEdge SE10000H-US EnergyHub SYSTEM SIZE AC 10.000KW a I I I N/A MOUNTING SnapNrack Ultra Rail UR-40 QTY.STRING/CKT. 3SHEET SHEET INDEX _I I I 80 STANCHIONS Snapnrack 242-01220 L Foot ELECT.SERVICE 120/240V-10 NUMBER SHEET TITLE N -- R 1 N/A RSD DEVICE INTEGRATED IN INV&OPT ROOF COVERING Comp Shingle ��1 COVER SHEET z 2 BATTERIES SolarEdge BAT-1OK1P ...5 O -- - - -- --—CALVIN TERRACE —(•- -- __ _ N/A COMBINER(S) N/A TILT 30',32',25' N-001 GENERAL NOTES a LO / I (E) MSP RATINGS 200A BUS/200A MAIN BREAKER AZIMUTH 200',201' PV-100R PV ARRAY LAYOUT U ,-IPROJECT TEAM LIST s 100 RACKING LAYOUT J c 1 I 5-200 SECTION ELEVATION 2 A I CONTRACTOR: ELECTRICAL UTILITY: Oc S-201 ATTACHMENT DETAILS > < El o I Valley Solar National Grid O Ic I 340 Riverside Dr METER NUMBER:66304290 E-001 EQUIP.CALCULATION 0 m > Florence,MA 01062 PHONE: E-002 WIRE AND COND.CALLS = c LI C a NW\ CONTRACTOR UC It21134A AUTHORITY HAVING E-003 THREE LINE DIAGRAM d m Z ud '.- PHONE:(413)584-8844 JURISDICTION: E-100 ELECTRICAL LAYOUT 3 CONTACT NAME:Lilian Wanjiku P-001 STANDARD PLACARDS Y v+ NORTH PHONE:(413)584-8844 BUILDING:City of Northampton 8 ' Ln 1 I EMAIL•jstocker@valleysolar.solar PHONE: P-002 DYNAMIC PLACARDS a Cs O a PROJECT APN: ENGINEERED BY: R-1.xx EQUIP.CUT SHEETS .-I z a a GENERAL PROJECT&JURISDICTIONAL NOTESScott E.Wyssling Jake DESIGNtocker 76 North Meadowbrook Dr o` g INSPECTION REQUIREMENTS JURISDICTIONAL&USTING REQUIREMENTS Alpine,UT 84004 a - 1.WHEN APPLICABLE A SMOKE DETECTOR,APPROVED AND LISTED BY THE PHONE:(413)584-8844 p p O .4 1.A LADDER SHALL BE INPLACEFORINSPECDONINCOMPLIANCE WITH ALL STATE FIRE MARSHAL ORANSINL 217 CERTIFIED TO NATIONAL FIRE ALARM EMAIL:jstocker@valleysolar.solar LICENSE#:50507 N w a N OSHA REGULATIONS. AND SIGNAUNG CODE,NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED LICENSE TYPE:Civil IN ALL APPLICABLE CODE REQUIRED LOCATIONS. YV y.m-I Z.PENDING LOCALJURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLE PROJECT DRAFTER: PHONE:(202)874-3483 g y a ALL ELECTRICAL ENCLOSURE DEAD FRONTS,COVERS,DOORS,ETC.SHALE BE 2.ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHER EMAIL:swyssling@wysslingconsulting.com m `_" OPEN AND ACCESSIBLE FOR INSPECTIONS.WHEN TRENCH AND ROOF INSPECTIONS JURISDICTIONAL AND UTIUTY APPROVED ASSOCIATION OR NATIONALLY Advanced Solar Solutions ARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOB INSPECTOR. RECOGNIZED ORGANIZATION. 2372 Morse Ave#912 u 3.FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPUCABLE CODES LISTED Irvine,CA 92614 IN GOVERNING CODES SECTION,ALL MANUFACTURES'LISTINGS,INSTALLATION J�// INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. Or. ` 4.REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCAL SOLAR /1 AR 50LUTJONS W NOTMATCHJURISDICTIONIF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES µ yTH OF MATCH THE APPROVED BUILDING PLANS.ADDITIONAL FEES MAY ALSO APPLY. PHONE:559-321-7000 y: Sc L .'4, �, 1 5.THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDED EMAIL•info@advpermits.com J AND PLACED BY THE CONTRACTOR AS PER APPLICABLE LJTIUTY OR AIU REQUIREMENTS. HOME OWNER PROJECT LOCATION: I W--f 'N re Steinfeld,Aaron -` E Q,�• D 12 Calvin Terrace,Northampton,MA 01060 /' FHA4- COPYRIGHT NOTICE 1.UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSED CONTACT NAME:Steinfeld,Aaron 1A WRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR PHONE: SOLUTIONS IS A VIOLATION OF U.S.COPYRIGHT LAWS AND WILL BE SUBJECT EMAIL: Signed 02-02-22 TO CIVIL DAMAGES AND PROSECUTION. GENERAL NOTES:* GROUND,IN COMPUANCE WITH NEC'250.134 AND AEC MICROINVERTER BRANCH CIRCUITS SHALL BE CONNECTED SUNLIGHT IN ACCORDANCE WITH 2020 NEC N 250.136(4). TO A SINGLE OCPD IN ACCORDANCE WITH THEIR 3/ll./5(H)(i)(4)(c) LLJ VS PROPER ACCESS AND WORKING CLEARANCE AROUND INSTALLATION INSTRUCTIONS AND NEC 690.9 H EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PV EQUIPMENT INCLUDING MODULE FRAMES AND OTHER EXPOSED UNGROUNDED DC PV SOURCE AND OUTPUT 0 PROVIDED AS PER SECTION NEC 110.26. METAL PARTS SHALL BE GROUNDED IN COMPLIANCE DISCONNECTS AND OCPD NOTES:* CIRCUITS SHALL USE CONDUCTORS LISTED AND IDENTIFIED I Z WITH NEC'690.4.7 AND MINIMUM GROUND —I AS PHOTOVOLTAIC(PV)WIRE IN COMPUANCE 2020.\'EC a PV SYSTEM COMPONENTS;INCLUDING BUT NOT LIMITED CONDUCTORS SIZED IN ACCORDANCE WITH.YEC'TABLE ALL DISCONNECTING SWITCHES WILL BE CONFIGURED SO Q 250.122. 690.31(C)(1). PV MODULES WIRE LEADS SHALL BE LISTED a CC TO,MODULES,INVERTERS AND SOURCE CIRCUITTHAT ALL ENERGIZED CONDUCTORS WHEN DISCONNECT IS FOR USE WITH UNGROUNDED SYSTEMS IN COMPLIANCE "' L uZ COMBINERS ARE IDENTIFIED AND LISTED FOR USE IN PV OPEN SHALL BE ON THE TERMINALS MARKED,"LINE SIDE" w L.. CONDUCTIVE PARTS OF MODULE FRAMES,MODULEWITH 2020 NEC 690.4(11) t LU SYSTEMS IN COMPLIANCE WITH NEC'690.4 A.\"D 690.6 (TYPICALLY THE UPPER TERMINALS) AND ALL El,(EC,IEEE CLASSIFICATIONS AS RACKING,AND ENCLOSURES SHALL BE GROUNDED IN (.9 COMPLIANCE WITH NEC 250.134 AND NEC 250.1.i6(A). REQUIREMENTS. ALL AC DISCONNECTS SHALL BE LABELED,LOCKABLE,OF PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE IN z vi UL2703 APPROVED MODULE AND RACK GROUNDING VISIBLE BREAK TYPE SWITCH WITH EXTERNAL HANDLE AND COMPLIANCE WITH NEC'200.6(.4)(6). n RAPID SHUTDOWN NOTES:* ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL rw-N SHALL BE USED AND INSTALLED PER MANUFACTURER'S PV MODULE CONDUCTORS LOCATED UNDER ARRAYS WILL G.`S a--I INSTALLATION MANUAL.IF C"I,2703 APPROVED AC DISCONNECTS SHALL BE A C "KNIFE BLADE"TYPE BE SECURED IN A WORKMANLIKE MANNER IN 0 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDIDNG GROUNDING IS NOT USED,MODULE GROUNDING LUGS 0 9 SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT DISCONNECT.IF EXTERIOR,RATED TO NEMA 3R OR BETTER COMPLIANCE WITH .\'F('l//1.11. MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG > Z CONTROLS SPECIFIC PV CONDUCTORS IN ACCORDANCE HOLES PER THE MANUFACTURER'S INSTALLATION PER NEC 110.28 WATERPROOFING: > WITH 2020,VEC 690120)-(D) REQUIREMENTS. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED EQUIPMENT LOCATIONS&ELECTRICAL THE GROUNDING CONNECTION TO A MODULE SHALL BE WHERE THE INVERTER IS NOT ADJACENT TO THE UTILITY ALL NEW ROOFTOP PENETRATIONS SHALL BE SEALED AND * ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES AC DISCONNECT,OR NOT WIHTIN SIGHT OF THE UTILITY AC MADE WEATHER TIGHT WITH APPROVED CHEMICAL NOTES: NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER DISCONNECT.2020 NEC 690.15(4) SEALANT AND FLASHINGS WHERE REQUIRED PER CODE AND GENERAL BUILDING AND ROOFING WORKMANSHIP LA JUNCTION AND PULL BOXES ARE PERMITTED TO BE MODULE. BOTH POSITIVE AND NEGATIVE PV CONDUCTORS REMAIN STANDARDS BY A LICENSED CONTRACTOR. z INSTALLED UNDER PV MODULES IN COMPLIANCE WITH UNGROUNDED.THEREFORE,BOTH SHALL REMAIN OPEN 0- to THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH o NEC 690.34. WHERE A DISCONNECT IS REQUIRED IN COMPLIANCE WITH ALL EXTERIOR ELECTRICAL EQUIPMENT,SHALL BE NEMA U .+ NEC 690.47 AND.\EC 250.50 THROUGH SEC•150.106' 3R OR BETTER RATED.ALL EXTERIOR CONDUIT AND Q O IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE,A 2020 NEC 690.15(D) Q ADDITIONAL AC ISNE SHALL BE PROVIDED CONNECTORS SHALL BE RATED FOR WET LOCATIONS. c A WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC GROUNDING ELECTRODE SYSTEM WILL BE PROVIDED IN 0 o COMPLIANCE WITH NEC 250,NEC 691147 AND.4HJ. ALL OCPD RATINGS AND TYPES SPECIFIED SHALL BE IN SERVICING DISCONNECT.2020 NEC 690.15,4 ?.12 AND 240. `ALL NOTES ARE AS APPLICABLE TO THIS PROJECT. >O 4 '- n O COMPLIANCE WITH NEC\'EC 69ll.N,69/1.9, ll- DISREGARD ANY NOTES THAT DO NOT APPLY TO THIS I- ' c E ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO PV SYSTEMS SHALL BE PROVIDED WITH DC S PROTECTION1110 NEC69l1.4!(H)GROUND- POSITIVE0 BOTH AND NEGATIVE DC PV CONDUCTORS ARE PROJECT. `' m 2QUQUALIFIED PERSONNEL IN COMPLIANCE WITH NECC FAULTUNGROUNDED;BOTH REQUIRE OVERCURRENT a 'a: N 0 APPLICABLE CODES. INTERCONNECTION/POC NOTES:* PROTECTION IN COMPLIANCE WITH NEC 690.9 3 v' - z ALL COMPONENTS ARE LISTED FOR THEIR INTENDED ARC FAULT(AFCI)DC CIRCUIT PROTECTION IS REQUIRED 0 o 0 w `lal" z PURPOSE AND RATED FOR OUTDOOR USAGE WHEN ALL LOAD-SIDE INTERCONNECTIONS ARE IN COMPLIANCE FOR ALL PV SYSTEMS ON OR PENETRATING A BUILDING N i o o APPLICABLE. WITH 20211.\•E('705.12(IJ) WITH A MAXIMUM SYSTEM VOLTAGE OF 80 VOLTS OR ¢ a GREATER.ALL DC PV CIRCUITS INSTALLED IN OR ON STRUCTURAL AND INSTALLATION THE TOTAL RATING OF ALL OCPD IN SOLAR LOAD CENTERS BUILDINGS WILL BE ARC-FAULT CIRCUIT PROTECTED IN o g 4 NOTES:* SHALL NOT EXCEED THE RATED AMPACITY OF THE BUSBAR COMPLIANCE WITH NEC 6911./I,C'1.1699H AND SHALL BE c 72 0 EXCLUDING THE OCPD PROTECTING THE BUSBAR IN LISTED AND LABELED IN ACCORDANCE WITH CL 1699(B). - - , w COMPLIANCE WITH SEC 705./1(H)(2)(-4)(c') /_�'' 8 RACKING SYSTEM&PV PANELS MOUNTED ON A P `" a .`". ROOFTOP SHALL BE LISTED AND LABELED IN ACCORDANCE ALL FEEDER TAP(LOAD SIDE)INTERCONNECTIONS ARE IN WIRING&CONDUIT NOTES:* f F. ;s WITH CT 1703 AND SHALL BE INSTALLED IN ACCORDANCE o'' WITH THE MANUFACTURER INSTALLATION INSTRUCTIONS. COMPUANCE WITH 2020 NEC 705.J2(H)(1)(I) ALL CONDUIT AND CONDUCTORS SHALL BE APPROVED THE PV SYSTEM BACK-FEED BREAKER SHALL BE INSTALLED FOR THEIR INTENDED PURPOSE INCLUDING WET ALL PV RACKING ATTACHMENT POINTS SHALL NOT EXCEED ON THE OPPOSITE END OF THE BUS BAR AND IT SHALL LOCATIONS AND EXPOSED TO SUNLIGHT.CONDUIT AND ,' -- THE PRE-ENGINEERED MAX SPANS OUTLINED BY THE CONDUCTOR SIZE SPECIFICATIONS ARE BASED ON THE •0 ALSO BE SIZED APPROPRIATELY AS PER 2020NEC RACKING MANUFACTURES ENGINEER OF RECORD. ,11;71(H)(2)(?)(b) MINIMUM CODE REQUIREMENTS AND ARE NOT LIMITED _ _3 TO UP SIZING. Signed 02-02-22 ,R GROUNDING NOTES:* SUPPLY SIDE TAP INTERCONNECTIONSAREIN L J COMPLIANCE WITH SEC•705.12(4)WITH SERVICE ALL CONDUCTORS SHALL BE SIZED IN COMPLIANCE WITH "ni Q IN UNGROUNDED SYSTEMS ONLY THE DC CONDUCTORS ENTRANCE CONDUCTORS IN COMPLIANCE WITH NEC NEC 690.8,NEC 690.7. ARE UNGROUNDED AND REQUIRE AN EQUIPMENT 231642 GROUNDING CONDUCTOR.ALL METAL ELECTRICAL ALL CONDUCTORS SHALL BE 0ERATED AS APPLICABLE TO ;I,. EQUIPMENT AND STRUCTURAL COMPONENTS BONDED TO BACKFEEDING BREAKER FOR INVERTER OUTPUT IS EXEMPT THEIR RESPECTIVE ENVIRONMENT INCLUDING DIRECT / FROM ADDITIONAL FASTENING 2020 NEC 705./2(H)(5) PVAC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL NOTE:ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 2015IFC ROOF ACCESS REQUIREMENTS I— WITH EXTERNAL HANDLE VISIBLE,LOCKABLE&LABELED A.THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. D WITHIN DO FEET OF THE METER SHADED DASHED UNE NEAR PERIMETER OF STRUCTURE EXTERIOR IS 0 _ MI APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION B.PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOT J ---- - BE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE _ AND GEOMETRY OF THE PHOTOVOLTAIC MODULE.ACTUAL PHOTO VOLTAIC MODULE DIMENSIONS ME ON SHEET RODS Ec W Q 1 CC C.FOR THE PURPOSE OF CLARITY,ALL ELECTRICAL LAYOUT DETAILS ME K LOCATED ON SHEET E-1CO. O CC . NEW < QN F > CI- CCEU, UI DE 1--? 0 0 0 DE 0 o I-4 Q. x ,I SECTION /-- H 4 g I I 0. $o 0 g RA ® I PV SITE LAYOUT LEGEND c u f O 2 2 c SEC1 PVMMx TAG ® ROOF ACCESS POINTI RE SECTION 0 ® SITE ACCESS 0 Q I- d 1 MODULE GROUP I- Mk E E GATE ACCESS 0q = E V 1 I I \��\\\\� AZIMUTH AND TILT TABLE °J ^L �, z smnxa ALMVM coos PFFDX/nT Y • SECTION-1 200 32' g w en 4 4■ ySH OF / • SECTION-2 200 30' r`I Q LEE a 0 0 o A'''' SECTION-3 200 32° z c c a I • SC. ,i,\ SECTION-4 201 25'I a 1 • IL. 0 Fop rn y o SECTION \ / ��s 3S' Y��e x E. 3 `..\,.... I I / ONAL E N a .a 02-02-22 SQUARE FOOTAGE CALCULATIONS P o v Signed LL ROOF RFFEaEN[E MAIM IOOFAGE EXISTING ROOF 1531 SECTION /� SECTION-1 95 2 \` ` \\\\\\ 1 SECTION-2 325 w SECTION-3 57 `n SECTION-4 57 °n J SECTION ......./.**,./..-1 TOTAL PERCENTAGE 3a.88% > Q 1 I / L •EXISTING DIMENSIONS ARE APPROX. L NORTH CONFIRM ALL DIMENSIONS SHOWN L Aggir QTY28 REC Group REC400AA BIX MODULES QTY 1 SolarEdge SE10000H-US EnergyHub INVERTER SCALE:1/8"=1'0"@ SHEET SIZE A3 SHEET NOTES A.FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF 0 RAT TO 7:12,THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 3'.E'ANO ANCHORS IN ADJACENT ROWS SHALL BE ›.- STAGGERED UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS. I- C (7 0. Z B. ANCHORS ARE ALSO KNOWN AS'STAHOR SP,"MOUNTS, L)E — OR"STANCHIONS."HORIZONTAL ANCHOR SPACING IS ALSO o KNOWN AS'CROSS-SLOPE'OR"EAST-WEST"ANCHOR WI- U SPACING.MAXIMUM HORIZONTAL ANCHOR SPACING SHOWN Q IN DETAIL.UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND K D LOCAL REQUIREMENTS.SEE -TABLE OF DIMENSIONS"EACH SECTION DETAILED FOR N HORIZONTAL ANCHOR SPACING. W G N C. SEE SHEET S-200 FOR SPECIFIC RACKING COMPONENT Q N ID MANUFACTURERS. 0 N 0 O S"I 4.11 �11!��1 PV RACKING LEGEND a F 11'-11W I I ROOF RACKING RAIL ' • I-1 ROOF RACKING RAIL SPLICE I---I I I ROOF RACKING SECTION PR ARRAY TAG I❑° I STANCHION W/ SECTION R N I I RETRO FIT FLASHING 1 MODULE GROUP Z L-J •DETNIS IN TOP VIEW CO EXISTING ROOF CONSTRUCTION U o gr° COMPONENT TYPE Q OC ROOT INFO r y, Q CONSTRUCTION Rafter-Simple Attic 22'O.C. J C FRAM WGINFO 2"XS"�22'OC MAX OC 0 � ` C ` O ROOFING COVERING Comp Shingle 0 Q ~ d RACKING MAX PSF 293 PSF ~ L, w N RACKING BILL OF MATERIALS(BOM) I u COMPONENT OTT MODEL LENGTH a N Z PV RAILS PV RAIL SPLICE 1 oC NI KA iim . PV RAIL2 F-i W W Z 7'.r !plan!!plan! PV RAIL SPLICE 2 . Q 0Q 0 < RAIL TO ROOF N Z Q O # `uu,SH OF ATTACHMENTQ Sr y\ Lal i T `, vn. L '', a N o 16 $IIJIII _ 7A,w7wurEmm7meAnr Signed 02-02-22 J iFiW �._29 10}4 a —I A > AM/\ •EXISTING ROOF DIMENSIONS ARE APPROX. NAV CONFIRM AU.DIMENSIONS SHOWN NORTH QTY 29 NEC Group REC400AA BUS MODULES QTY 1 SolarEdge SE10000H-US EnergyHub INVERTER SCALE:1/8"=1'O"@ SHEET SIZE A3 1 SIMPLE ATTIC/RAFTER-PORTRAIT SCALE:NTS 2 SIMPLE ATTIC/RAFTER-LANDSCAPE SCALE:NTS SHEET NOTES an Z A. THESE NOTES APPLY TO RARER ROOF CONSTRUCTION. 0 © •IF BLOCKING REQUIRED © I; •IF BLOCKING REQUIRED B. THE ROOF STRUCTURE CONFORMED TO BUILDING CODE H 5-201 5-201 REQUIREMENTS AT THE TIME IT WAS BUILT. Q C. THE ROOF SHEATHING IS AT LEAST 7/16'THICK ORIENTED I-- L> ® STRAND BOARD OR PLYWOOD.IK SKIP SHEATHING IS J RISE 12v . •.F 00 PV j E. RISELv . .., �© PV j ACCEPTABLE. AL w - _ 5-201 D. THE SOLAR ARMY DISPLACES ROOF WE LOADS(TEMPORARY O. Z _ 5-201 `IL _ — CONSTRUCTION -- I�I_ '� r �\ 0 © �- i,`�_ r `\ 0 © ESIGNED TO CAR�DE)THAT THE ROOF WAS ORIGINALLY 0 [] A \ I ,,\ E2 CC N is,,,,..... .O � .BRRE -- \- .10 E. IF THE ROOF COVERING IS SHINGLES:ITSHALL BE NO MORE VI- IV D2 ? `-`— 02 ���— THAN TWO LAYERS.(SHOWN) ALI w . 3 FRAMING D3 _ ,`� FRAMING AM m In mho F. IF ROOF COVERING IS TILE;ITS A SINGLE LAYER.ALL TILES ON CC„�, CIL RIDGE SEMI DZtai I RIDGE BEAM 02 t PLANE OF PV COMPONENTS ARE SECURE. N (NOT SHOWN IN DETAIL) r4 ----- -_-_--_-_ ' --------------- --------- G. THE ROOF STRUCTURE IS STRUCTURALLY SOUND,WITHOUT V- HS3 OH1 HS1 OH1 SIGNS OF ALTERATIONS OR SIGNIFICANT STRUCTURAL o n CD HORIZONTAL SPAN HORQONTM SPAN DETERIORATION OR SAGGING. 0 H. THE PV MODULES ARE PARALLEL WITH THE ROOF SURFACE. O N I. THERE LS A Y TO SO'GAP BETWEEN UNDERSIDE OF MODULE > W ••COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENT FOR STANDING SEAM METAL ROOF APPLIES. ••COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENT FOR STANDINGAND THE ROOF SURFACE.(SEE TABLE OF DIMENSIONS'Er) SEAM METAL ROOF APPLES. C TABLE OF DIMENSIONS TABLE OF DIMENSIONS 1. UPSLOPE ANCHOR SPACING MAY VARY FROM USTED TABLES. STANCHIONS CAN BE PLACED NO CLOSER THAN 24.O.C. DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS K. DETAILS SHOWN ME A REPRESENTATION OF EXISTING ROOF Oil OVERHANG IN THIS AREA R1 RIDGE BEAM DEPTH OH1 OVERHANG IN THIS AREA RI RIDGE BEAM DEPTH ARE SHONS.ARDAL FIELD USE O YNSFER TO TABLES FOR CO SHOWN FOR DIAGRAM CO ONLY.REFER V RY.ES FOR RISE ROOF PITCH 30",32",25" R2 RAFTER DEPTH THIS AREA 55" RISE ROOF PITCH 3O",32",25" R2 RAFTER DEPTH THIS AREA 5" DESIGN CRITERIA. In HI PV MODULE HAT.ABOVE ROOF 3"-6"TYP ASS HORIZONTAL SPAN Ill PV MODULE HGT.ABOVE ROOF 3"-6"TYP HS1 HORIZONTAL SPAN L ALL PLUMBING AND ROOF VENTS SHALL NOT BE OBSTRUCTED Z MAX RAFTER SPAN HST HORIZONTAL SPAN MAX RAFTER SPAN NS2 HORIZONTAL SPAN BY PV MODULES AND EQUIPMENT. QJ M. UPSLOPE ANCHOR SPACING UPSIOPE ANCHOR SPACING 0_ 8.H DL RAIL OVERHANG 17.92" D3 STANCHIONO.0 36.1" DI RAIL OVERHANG 9.6" 03 STANCHIONO.C. 19.45" 02 STANCHION D.C. 35.85" D4 MIN./MAX.STANCHION O.0 D2 STANCHION O.C. 19.2" D4 MIN./MAX.STANCHION O.0 J C U 2 _ 0 O A c 3 STANCHION DETAIL SCALE:NTS 4 SCALE:NTS PV RACKING LEGEND oO Q F n 1•-10" 3,B" I I ROOF RACKING RAIL 0 c I- w T m [� ROOF RACKING RAIL SPACE = C t. T. O TYP. MAX ROOF RACKING SECTION AO 3� N 2 Or T H OF REMOFIT FLASHING W/ 1 MODULE GROUP Y e`~,�1. P RIN FIT SECTIONORSIDE R N SC„.'a •DERAILS IN DR NEW N 6 Ir,.-� r-� -� /.' WY. L EXISTING ROOF CONSTRUCTION Z a 0 '' �1 1�1 LL� _ , L_.1 L_.1 L_J , •NO SOL y _ COMPONENT TYPE(� MEAN ROOF XGT MAX 25' O N 01�\ /\£ AST-- ,..0' ROOFING, ROOFING COVERING Comp Shingle Q E _, I © "IOIYAL E7� v TABLE OF COMPONENTS - a V 3 Hf �k .'\OQO n i©� 1-1 ®i i®� Signed 02-02-22 �1 mTYPE 1 MODEL PH V u F. L-J L _J L_J 1 WRMITYPEI Ultra Rail UR-IO RR V \ N:s.......0:0° L 2 PV RAIL SPLICE TYPE PER MIL MANUFACTURER 1.4! 3 PV RAIL 2 NOT USED f—1 I--1I r-1 l 4 PV RAIL SPLICE TYPE 2 PER RAIL MANUFACTURER 423 Q i ®1 ®� • i i--1i I S STANCH/ONION CH/ON z12i11Z20 L Foot L_J L_J L_J L_J 6 FLASHING L-FOOL Flashing 7 MID CLAMP PER RAIL MANUFACTURER W I \ `— B EMI CIAMP PER RAIL MANUFACTURER A J (E)FRAMING @ a ASSUMED 22'O.0 J r-� r-� r_ii TYPICAL PARTS UST I L L L I r ITEM Or/ PART NUMBER DESCRIPTION L_J i_®J L_ -_J Ti 1 1 242 92266 SNAPNRACK,UMBRELLA LAG,TYPE 3,4IN,SS _ 2 1 242-01219,242-01220 SNAPNRACK,ULTRA FOOT FOR U FLASHING,SILVER/BLACK / / 1l 3 1 232-01375.232-01376 SNAPNRACK,COMP FLASHING,9IN X 12IN,SILVER/BLACK ALUM 1 STANCHION ATTACHMENT DETAIL WITH FLASHING SCALE:NTS 2 RAIL SPLICE DETAIL-HORIZONTAL RAIL SCALE:NTS SHEET NOTES Ln J 1.A MINIMUM OF(1)5/26'DIAMETER LAG SCREWS WITH 2.5• Q EMBEDMENT INTO THE RAFTER USED,CA THE ANCHOR FASTENER MUST MEET THE MANUFACTURER'S ENGINEERING. W 2.ADHERE TO RACKING MANUFACTURERS INSTALLATION C) INSTRUCTIONS PERTAINING TO CANTILEVER. F, F _ f Z OC W a L MODULE END PV MODULE, W IA M o Q CLAMP BY OTHERS E--- , (_ Y ---- ul } , ---- - 111. '� SNAPNRACK L_. _.._� '3 < ULTRA RAIL L-FOOT STAGGER STANCHIONS WHERE POSSIBLE. N N 5/76'-18 X 2-1/4' L-FOOT FLASHING SEE SHEET"S-100"FOR: tWp. SS HCS BOLT HORIZONTAL ANCHOR SPAN SPACING. a l0 ‘-(E)FRAMING 0 O TYPICAL o lV N r , SPACING VARIES - y i W ec (E)ROOF SHEATHING -�� its - --_---— - L"") I Y - l�--- /DECKING � _J L L 1 ALL ANCHOR LAGS TO BE MINIMUM 2-1/2" (E)FRAMING MEMBER PV RACKING LEGEND I'-. O O / / v' EMBEDMENT INTO FRAMING MEMBERS ROOFRAIXINGML Z 2/3"OF TOTAL SPAN MAX/ C I ROOF RACKING RAIL SPLICE a IL MANUFACTURER a. RAIL SPLICE KIT ROOF RACKING SECTION PV ARRAY TAG 1/3"OF TOTAL SPAN MAX ❑R STMla1ON W/ SECTION lJ p SEE"S-100/TABLE OF COMPONENTS' RETRO FIT FLASHING 2 MODULE GROUP Q 6H < •MLOUIFS SHOWN PORTRAIT IN EXAMPLE J C m •DETAILS IN SECTION OR SIDE VIEW Q G G 3 RAIL EXTENSION DETAIL SCALE:NTS 4 RAFTER HOLE AND CONSTRUCTION DETAIL SCALE:NTS p a a I- a.S E I- i .. 1 NOTE:W HERE FRAMING IS VISIBLE FROM ATTIC&/OR UNDERSIDE OF ROOF, _ u C D 1 I E I VISUALLY REVIEW FRAMING TO VERIFY THAT NO SIGNIFICANT STRUCTURAL a dry o I __I, I I DECAY OR UN-REPAIRED FIRE DAMAGE EXISTS. I^ .-' Z L--J Y Vy1H W N VH N Q C y EXTENSION OF RAIL RIDGE SAG IN INCHES NOT TO EXCEED RIDGE ` _„_-. .H z Q G 1/3 LENGTH IN FEET DIVIDED BY 20 L`■ "_u' OF RAIL OR STRUT CANT. E • N CONNECTIONS TO MEET MAX i 1 r---, RIDGE BEA NOTCHES DEEPER THAN 1/4" ; 1 0 8 WEIGHT REQ Of EQUIPMENT �,�, I I I NOT ALLOWED ALONG TOP OR �� - I ' a o I,I' 1/4 H BOTTOM EDGE OF FRAMING H t a 0 CONDUIT ® ) Lj ROOF TOP _� �/ tl'_-` M/DpHALFOwfD0/v /' ���n R el ; v �AND/OR If 1 K '•��' >fi.='_ FROM/ryG Pq m LL" ® t ! N -- 1 1 -1 i ,\ 1/4 Signed 02-02-22 COMPONENT+ I I I® I ? _ IIII l 2"FROM SIDE J yL -- i t 2• — — — — y's W OF MODULE ;, ; FRAMING SAG IN INCHES NOT J VERIFY THAT NO .r• TO EXCEED FRAMING LENGTH "~ J DIAGONAL AND/OR VERTICAL IN FEET DIVIDED BY 20 ATTIC/FRAMING STRUT MEMBERS HOLES ALLOWED ONLY IN MIDDLE THIRD r--� r--� ARE CUT OR NOTCHED OF FRAMING DEPTH,•R2,AND NO LARGER El I THAN•R2/4 IN DIAMETER.MINIMUM IA M P AI •MODULES SHOWN PORTRAIT IN EXAMPLE I F I I I I F SPACING BETWEEN HOLES AT•R2 ••RUNG SHOWING IN VERTICAL.IN EXAMPLE 4--J I---J •SEE DETAILS'1-2/S2DLP TABLE OF DIMENSIONS PV MODULE#1 SPECIFICATIONS DC COMBINER/DISCONNECT#1 STRING INVERTER#1 SPECIFICATIONS AC DISCONNECT#1(IF APPL) 1!) MANUFACTURER REC Group MANUFACTURER MANUFACTURER SolarEdge MANUFACTURER Eaton Z MODEL NUMBER REC400AA BLK MODEL NUMBER MODEL NUMBER SE10000H-US EnergyHub MOTEL NUMBER DG222URB O WEIGHT 45 A. OCPD(DISCONNECT TYPE) QUANTITY 1 INVERTER(S) QUANTITY 1 IACDISCO.(S) Q DIMENSIONS 71.7 x 38.4 x 1.2 L'xWxD'/MIX WEIGHT Ibs NOMINAL POWER RATING 10000 WATT AC DISCONNECT DEVICE TYPE NON-FUSIBLE DISCONNECT --I PEAK POWER•STC(Pma) 400 WATTS NEMA RATING WEIGHT 30.2 Ihs. RATED OPERATIONAL VOLTAGE 120/240 VOLTS f U Vac(OPEN-CIRCUIT 48.8 VOLTS DC LOCATION TION OF COMPONENT DC INPUT RATED CURRENT 60 A - XL Q VmPIMAX-POWER VOLTAGE) 39.7 VOLTS OC DC INPUT Max INPUT DC VOLTAGE 264 VOLTS DC NUMBER OF POLES 2 P O.O L..) be(SHORT-CIRCUIT CURRENT) 10.1 AMPS SERIES FUSE RATING FOR PV MODULES AMPS(OCPD) Min.MPPT VOLTAGE RANGE 380 VOLTS DC NEMA RATING 3R *PP(OPERATING CURRENT) 9.51 AMPS QUANTITY OF PV SOURCE CIRCUITS CITY Max.MPPT VOLTAGE RANGE 480 VOLTS DC FUSE RATING N/A AMPS ul IA — MFR.Vac TEMP COEFFICIENT -0.24 TF/K MAX PV MODULE Voc VOLTS DC Max INPUT CURRENT 27 AMPS TOTAL INPUT CURRENT 42 AMPS w- d MAX SERIES FUSE RATING 20.0 AMPS MAX*OF MODULES IN CIRCUIT OTT MPPTQTY N/A K AG w TEMP.CORRECTED YOU 54.17 VOLTS DC MAX ALLOWED INPUT VOLTAGE VOLTS DC INTEGRATED DC DISCONNECT Yes COMPLY W/NEC 690.17 AC DISCONNECT#2(IF APPL) N MAX INPUT FUSE/BREAKER RATING AMPS INTEGRATED AC DISCONNECT NO MANUFACTURER N DC/DC OPTIMIZER (IF APPL) DC OUTPUT AC OUTPUT MODEL NUMBER QN MAX CIRCUIT OUTPUT CURRENT AMPS NOMINAL VOLTAGE OUTPUT 240 VOLTS AC QUANTITY (AC DISCO.%) p N MANUFACTURER SolarEdge Technologies MAX CONT.OUTPUT CURRENT AMPS MAX.AC APPARENT POWER 10000 WATTS0 DISCONNECT DEVICE TYPE G Q MODEL NUMBER 54405ingle-HD(240V) MAX OVERCURRENT PROTECTION(OCPD) 60 AMPS RATED OPERATIONAL VOLTAGE VOLTS LI 1.1 WEIGHT 1.5 A. DC COMBINER/DISCONNECT#2(IF APPL.) MAX.OUTPUT CURRENT 42 AMPS-MAX RATED OUTPUT be 15 AMPS RATED CURRENT AMPS TM MA%OUTPUT VOLTAGE 60 VOLTS MANUFACTURER NUMBER OF POLES P CZ MODEL NUMBER STRING INVERTER#2 SPECIFICATIONS(IF APPL) NEMA RATING MAX INPUT VOLTAGEVa 60 VOLTS OCPD(DISCOFNECr TYPE) MANUFACTURER FUSE RATING AMPS WEIGHT Ibs MODEL NUMBER TOTAL INPUT CURRENT AMPS BATTERY SPECIFICATIONS(IF APPL.) NEMA RATING QUANTITY INVERTERIS) LOCATION OF COMPONENT NOMINAL POWER RATING WATT AC IFAPPL. in MANUFACTURER/MAKE SolarEdge DC INPUT WRIGHTIbs. AC SUB-PANEL#1( ) Z $ MODEL NUMBER RAT-10K1P NEW OR EXISTING SERIES FUSE RATING FOR PV MODULES AMPS(OCPDI DC INPUT QUANTITY 2 MAKE/MODEL d QUANTITY OF PV SOURCE CIRCUITS QTY Max INPUT DC VOLTAGE VOLTS DC N WEIGHT 267 RN TYPEOFPANEL V MAX PV MODULE Voc VOLTS DC Min.MPPT VOLTAGE RANGE VOLTS OC O DIMENSION 31.1s 46.4X 9.84ExW.QISA NUMBER OF POLES P F Q MAX*OF MODULES IN CIRCUIT COY Max MPPT VOLTAGE RANGE VOLTS DC TOTAL ENERGY 9.7 KV/M@2S'C MAX ALLOWED INPUT VOLTAGE VOLTS DC Max INPUT CURRENT AMPS NEMA RATING J C y MAX VOLTAGE 450 VOLTS a 2e 0 MAX INPUT FUSE/BREAKER RATING AMPS MPPT OW BUSS BAR RATING AMPS COMINUOG OUTPUT POWER 5.00 KW DC OUTPUT INTEGRATED DC DISCONNECT SUB-PANEL MAIN BREAKER _ AMPS Q Q ` r I p- NRA CONTINUOUS OUTPUT CURRENT 14.3 AMPS @ COMPLY W/NEC 690.17 H 5 350V MAIN SERVICE PANEL P.O.C.BREAKER AMPS V E MAX CMCUTOUTPUT CURRENT AMPS INTEGRATED AC DISCONNECT MAX CONT.OUTPUT CURRENT AMPS AC OUTPUT SUM OF EXISTING CIRCUIT BREAKERS AMPS 0 C q t NOMINAL VOLTAGE OUTPUT VOLTS AC MAX ALLOWABLE SOLAR CURRENT AMPS 0- T.,. lNJ 0 DC COMBINER/DISCONNECT#3(IF APPL.) MAX AC APPARENT POWER WATTS PV BACKFEED BREAKER*1 AMPSWm%) Lo .H Z MANUFACTURER MAX OVERCURRENT PROTECTION(OM) AMPS PVRACKFEED BREAKER*2 AMPS(ImM) - 0*1 Vf MODEL NUMBER MAX.OUTPUT CURRENT AMPS-MAX PVBACKFEEO BREAKERI3 AMPS(Inwx) O w N z OCPD(DISCONNECT TYPE) PVBACBFEED BREAKER** AMPS(Imax) rN.I Q CC 0 0- WEIGHT AC COMBINER#1(SOLAR LOAD CENTER) Z a a NEMA RATING 1� MANUFACTURER MAIN SERVICE PANEL(IF APPL) LOCATION OF COMPONENT MODEL NUMBER NEW OR EXISTING'' EXISTING G LND DC INPUT RATED OPERATIONAL VOLTAGE VOLTS ELECTRICAL SERVICE 120/240V Single Phase < . .. SERIES FUSE RATING FOR PV MODULES AMPS(OCPD) RATED CURRENT AMPS BUSS BAR RATED CURRENT 200 AMPS xl IRS � Q CO QUANTITY OF PV SOURCE CIRCUITS CITY NUMBER OF POLES P MAIN BREAKER RATED CURRENT 200 AMPS > 2 N OTT MAIN BREAKER SIZE AMPS MAX ALLOWABLE SOLAR CURRENT 100% 0 AMPS m y MAX ALLOWED INPUT VOLTAGE VOLTS DC TOTAL INPUT CURRENT AMPS MAX ALLOWABLE SOLAR CURRENT 120% 40 AMPS(low) O MAX INPUT FUSE/BREAKER RATING AMPS NUMBER OF BRANCH CIRCUITS CIRCUITS PV BACKFEED BREAKER RI AMPS(Imaa) DC OUTPUT PV BACKFEED BREAKER*2 AMPS(NnaR) MAX CIRCLE'OUTPUT CURRENT AMPS AC COMBINER#2(SOLAR LOAD CENTER) PV RAGWEED BREAKER 0 AMPSWmax) '. MAX CONT.OUTPUT CURRENT AMPS MANUFACTURER PV BACKFEED BREAKER 44 AMPS(MOO 111 MODEL NUMBER ALT.ENERGY BACKFEED BREAKER(IF APIL) AMPS ax) �j On tax)RATED OPERATIONAL VOLTAGE VOLTS N RATED CURRENT AMPS W J PV SYSTEM MAXIMUM VOLTAGE(MODULE Voq,,,,E,J NUMBER OF POLES P Q DATA SOURCE I SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/EXPEDITED-PERMIT/MAP/ NEMA RATING > > TEMPERATURE MAIN BREAKER S AMPS EXTREME MIN. STC CORRECTED MFR.P�IEMP CORRECTEDSWMODULE Voc CORRECTED TOTAL INPUT CURRENT AMPS TEMPERATURE COEFFICIENT FORMULA TEMP. s TEMP.['CI rC) TEMPERATURE (41%/CI•100 COEFFICIENT NUMBER OPE TO�E VOL T NUMBER OF BRANCH CIRCUITS CIRCUITS -20 - 25 = -45 * -0.24% = 0.11 + 1 1.11 * 48.8 = 54.17 WIRE AND CONDUCTOR NOTES WIRE COLOR CODING(2020)NEC SECTIONS 250.119&200.6 v) I ANY CONDUCTOR LENGTH UNDER 50'DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS PV DC WIRING AC WIRING Q 2. BECAUSE WE ARE UNABLE TO DETERMINE THEEXAE PATH THE INSTALLER WILL RUN IMPRTORS;WORST CASE SESCENAAIOS,ROUNDING UP SIZES OF CONDUCTORS THAT ARE EQUIPMENT GROUND GREEN 00.BANE OR GREEN/YELLOW EQUIPMENT ROUND GREEN OR BARE,OR GREFN/1'EII.OW U DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING ONOUCTORS THAT ARE IMPROPERLY STIED. GROUNDED CONDUCTOR 3. WIRING METHODS IN THESE CALCULATIONS DON'T EXCEED IOOO VOLTS ANY COLOR OTHER THAN GREEN OR WHITE/GRAY (NEUTRAL) WHITE OR GRAY 0 4. CEC/NEC310.15(AX2)(AS APPLICABLE)WHERE TWO DIFFERENT AMPACITES APPLY TO ADJACENT PORTIONS OF AORCUIT,THE HIGHER AMPACITY SHALL BE PERMITTED TO BE CONDUCTOR(S). ANY COLOR OTHER THAN GREEN OR WHITE/GRAYf' Z USED BEYOND THE POINT OF TRANSITION,A DISTANCE EQUAL TO WO'(3 METERS)OR 10%OF THE CIRCUIT LENGTH FIGURED AT THE HIGHER AMPACITY,WHICHEVER IS LESS. UNGROUNDED C [ONVENTONGRED FOR GROUNDED SYSTEMS UNGROUNDED ALLOWED. O WHEN LESS THAN 30'-0"OR 10%OF THE CIRCUIT LENGTH;THE LESSER AMPACITY MAY BE USED. CONDUCTOR(5)HOT: CONVENTION G Ll BLACK CC U RED(H)AND BLAOL I-)FOR UNGROUNDED SYSTEMS LI AND L2 CONVENfIDN IS LT RED CL CI ES Z W Q DC WIRE AND CONDUIT SIZING CHART[SEE SHEET E-O03 FOR THREE LINE DIAGRAM] ~ w J CC CONDUCTOR CONDUIT FILL 111 m 3 REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK 1'4 CIRCUIT CIRCUIT SPECIFICATIONS DERATING TEMP. AMPACTTY /MIAOW N TAG ORIGIN DESTINATION QTY IN TEMP TRADE gMPAC17Y %c(AMPS) COMBINED MM ERATI REQUIRED CIRCUIT AMBIENT HGT. ADDER PER OPERAT. CORRECTION BOF CORRECTION COND. TEMP. CONDUIT CORRECTED REQUIRED CORRECTED W N PAMBLLEL RATING S'"'" !30'C COMPONENT 0. % PARALLEL % CURRENT X OPEMTON AMPACITY ENVIRONMENT TEMP. ABOVE 330.15 TEMP' 310.15 UNGRNO. l30.15 AMPACITY X DERATING X FILL AMPACITY AMPAQTY S AMPAOI'/ ~ MAT'F0.1AL 1C) PER 310.16 WMIsI STRINGS 690d IANl) �D.B(eNll (Q ROOF(In) (BN2NX1 CC) (sow CON-. mom DEBATNG oN N DCI PV MODULE OC/DC CONVERTER (1)CU 90 AWG 30 10.1 X 1 X 125 X 1.25 • 15.7E ROOFTOP 35 >7/8' 0 35 0.96 2 N/A 30 X 0.96 X LO • 299 15.72 5 289 0 C] - W DC2 DC/OC CONVERTER RINCYON BOX (1)CU 90 AqG 40 15 X 1 X 1 X 1.25 • 18.75 ROOFTOP 35 >7/8' 0 35 0.96 6 N/A 40 X 036 X 10 334 18.75 5 32.4 W _ - - -- CC DC3 RJNCTON BOX INVERTER (1(CU 90 A G 40 15 X 1 X 1 x 1.25 18.75 AMC 35 >7/B' 0 35 096 6 0.80 40 X 0.96 X 020 • 30.72 1275 S 30.72 DC4 BATTERY INVERTER (1)CU 90 AWCi 55 143 X 2 X 1 x 125 . 35.75 EXT WALL 35 N/A 0 95 096 2 1.055 X 0.96 X 1A • 522 35.75 5 522 DES X X X • X X S X, X X - x % - 1 11 oc6 Z DCY X X X • X X- • S 5 0 DB X X X - x x - s U G Q a c 5 2 O o c Q OO vcE O w ? N I T., N 0 61 .4 Z Y yy11 W 1n21 A r1 N Q O z a colt' O. AC WIRE AND CONDUIT FILL DERATE CHART[SEE SHEET E-003 FOR THREE LINE DIAGRAM] Z a a- Q CONDUCTOR REQUIRED CONDUCTOR CONDUIT FILL S r CONDUCTOR TEMPERATURE DERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK SPECIFICATIONS AMPACITY DERAT1NG M g TAG CIRCUIT ORIGIN CIRCUIT MAX WA.Donor TEMP. AMPACITY AMPACITY ,�A „ •o 4 DESTINATION QTYX3 TEMP TRADE AMPACITY CONE, QMRDITIAMR) REQUIRED CIRCUIT AMBENT ADDER PER OPERAT. CORRECTION B OF CORRECTION COND. TEMP. CONDUIT CORRECTED REQUIRED CORRECTED .. PARALLEL RATING N30'C OPEM110N z aR TEMP. ABOVE UNGRND. % % FILL k Y N B (.C) SET PER310.16 690b IBNl) co4�0xExr = AMIACDY ENVIRONMENT 310.15 TEMP.('CI 310.11 310.15 AMPACITY DEBATING - AMPACITY AMPACRY AMPACITY •'I > MATERIALWMPN ('CI ROOF(In) (BN2NX1 (B)12(14) COND. (0)(3NB) DEMTNW 29 AG 4) ACT INVERTER AC DISCONNECT (1)CU 75 AWG 65 125 X 42.0 52.5 INT/EXT WALL 35 N/A 0 35 0.94 3 10 65 X 0.94 X L0 . 61.1 525 S 61.1 Larn 61 .. - 0 AC2 AC DISCONNECT PRODUCTION METER (1)CU 75 AWG 65 1.25 X 42,0 = 523 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 65 X 0.94 X 10 • 61.1 52.5 S 611 -AC3 PRODUCTION METER BACKUP SYSTEM INTERFACE (I)CU 29 AWG 65 125 X 42.0 • 523 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 65 X 0.94 X 10 - 61.1 523 S IL1 AC4 BACKUP SYSTEM INTERFACE EXWTING SERVICE PANEL (1)CU 90 3/0 225 N/A x 203 200 INT/EDT WALL 35 N/A 0 35 094 3 1D 225 X 0.94 X 1.0 2115 200 5 2113 W A[5 BACKUP SYSTEM INTERFACE METER SOCKET (1)CO 90 fl/HH 225 N/A k 200 720 INT/E](T WALL 35 N/A 0 35 Q94 9 3A 225 X 094 % IA • 211.5 203 5 2113 RI-.. J AC6 - -X X X - 6 AWN ' J AR - -% -•- - - % % •- S % `Q A® - _ _X _• X X • S /J AO - _ "X •_ - X X • S �A ACID X • X X = S EC�C EQUIPMENT TABLE STENO MODULEQTY INVENT** LEGEND A TAN Qr COMPONENT 1 8 INV 1 /� 2 A 1 28 PV MODULES REC Group REMORA BLK 2 8 INVS DC CONDUCTOR TAG /1\ EQUIPMENT TAG < • 2 28 DC/DC OPTIMIZER 5440 Single-HD(240V1 3 12 INV 1 Q 4; al - -. ®I 3 1 DC DISCONNECT INTEGRATED IN INV AC CONDUCTOR TAG ND GROUND CONDUCTOR TAG 14.i " " I UNDERGROUNO CABLE FOR 3 MODULES 4 0 DC COMBINER BOX Uj I- 0 I A Iffli j 5 2 JUNCTION BOX SOlwe&k RSTC0799-5B ELECTRICAL NOTES s --Z-- - I I 6 N/A RAPID SHUTDOWN INTEGRATED IN INV&OPT• UNGROUNDED PVSYSTEMS: 2 •NVERTERS,MODULES,AND DC COMPONENTS MUST BE USTED J _ _ - i 7 1 DCC/OC INVERTER SOWEdge SEI00(IOH-US EnergyHUB FOR USE IN UNGROUNDED SYSTEMS,TYPICALLY BACK-FEED SOLAR BREAKER: N/A LI.I I MODULE NAMEPLATE B 0 DISCONNECT TRANSFORMER-LESS GI) VWyFI LA W ( A� 1 1 9 1 AC DISCONNECT(INDEPENDENT) Eaton W222URB CONDUCTOR TABLE CONDUIT TABLE •OCPE'S WHERE NECESSARY MUST HAVE DISCONNECTING MEANS. •_i cc RATING 400W _ I 10 0 50CM LOAD CENTER - •PV SOURCE ORCUITS MUST BE EITHER PV WIRE AND LISTED FOR m j- _ _ I I TAG CIT. S� 1VPB GEOYNO SCE WPM WET LOCATIONS OR IAOEETED MULTI-CONDUCTOR CABLES AU 1) 11 ' ' : 11 1 GENERATION METER MA SMART GENERATION METER DC1 2 B12 AWG PV Wire N6AWG N/A Open AA INSTALLED IN RACEWAY. cc a I I I 12 0 SUB PANEL .THE AC SIDE IS STILL GROUNDED ON THE NEUTRAL CONDUCTOR. N 1 . . DCZ 7 *10AWG PV Wire PS AWG N/A OpenNr I A o • 13 0 AC DISCONNECT(FUSIBLE) REQUIRE EQUIPMENT GROUNDING BUT DOES NOT NAVE SYSTEM W O • I 1 I I DC3 7 M30 AWG THWN-2 BB MEGAWG 3/l Inch EMT GROUNDING;NO DC CURRENT-CARRYING CONDUCTOR IS I-Q I ' . ' 14 1 AUTO TRANSFER SWITCH SolarEtlge BEEUSGN-01 - DU 3 NB AWG THWN-2 NB AWG 1/2Ind, EMT CONNECTED TO GROUND.THESE CONDUCTORS ARE COLOR Q{D En fL gl i. 1 1 1 15 1 EXISTING MAIN SERVICE PANEL 200A BUS/200A MB 06 CODED DIFFERENTLY THAN GROUNDED PV SYSTEMS. 0 Q 1 I I 1 16 1 EXISTING UD W Lf1Y METER 120/2! -lm OC6 AC/DC ELECTRICAL NOTES( O ALL OVERCURRENT PROTECTION DEVICES WPM)MUST BE LlI _ n� ' ' ' 17 2 BATTERY SolarEMge BAT-10K1P UCT RATED FOR 600 VOLTS ON THE DC/PV POWER SIDE i • I I I - 18 O THE INVERTER. W F 'I 1 1 1 1 I NOTE:EQUIP TAGS MAY NOT BE IN SEQUENTIAL ORDER,N/AIRED DCB CL •EXTEPoOR ENQQSURESTO BE NEMATYPE 3R OR BETTER. SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS Aci 4 BAAWG T1IWN-2 El AWG finch EMT •AUL CONDUIT AND CONDUIT CONNECTIONS SHALL BE RATED A . 1 I I I I AC2 4 N6AWG THWN-2 NBAWG 110h EMT INTERCONNECTION NOTES:FOR WET AND DAMP L OTONS WHEN APPLICABLE. , I AC9 4 IN AWG THWN-2 BB AWG 1kRh EMT •TERCONNETION ESAXERS MUST BE SUITABLE FOR ' 1 1 1 I I ACI 4 N3/O AWG THWN-2 NBAWG 21ndR EMT BACKFEEDING.NEC INFORMATIONAL NOTE: • 'Ti �1 `• FUSED DISCONNECTS,UNLESS OTHERWISE MARKED, 1 1 1 I I ACS 9 MVO AWG THWN-2 MAWG 1-1/21nch EMT ARE SUITABLE FOR BACKFEEDING. N _FP.__Tl__ - ACE •690.13(F)(2)DEVICE MARKED WITH'LINE"AND ROAD-SHALL Z AC7 5 El- 1 1 1 1 I I NOT BE PERMITTED FOR BACKFEED OR REVERSE CURRENT O I ! mil ACE •705.12(BXS)ORCUIT BREAKERS BACK FEED FROM UTILITY O. G 'A� INTERACTIVE INVERTERS)ANTI-ISLANDI NG.UL 1741 CERTIFIED) L.l 0 I • AC10 •NO CENTER-FED MAIN BREAKER.PANEL F Q NOTE:CONDUCTORS ACTAC2,AC3,AC4,AC5 G ACB ( 1 - -EIHIIHIIH- /� CONFIGURED PER NEC 705.12 A J C u * /5\ MAY BE TMNN-2 OR SECT CABLE0li! C /r GI 2 I/1^T6� 'INCLUDES GROUND&CURRENT CARRYING CONDUCTORS O 1 1 1 1 1 1 ©,V I To a 2 1 1 1 1 1 1_® I 4,_.....THE BATTERY WILL ONLY BE CHARGED BY PV. 1 1 Y W111111 THE BATTERY WILL DISCHARGE TO ON SITE LOADS. READILY ACCESSIBLE OPEN BLADE AC 1 . 7 5W1(CH 1 8 2 t2 re Z THE BATTERY DISCHARGES TO THE GRID ONLY IF SYSTEM DISCONNECT(UTILITY ONLY) i• jil E�_� r eV Q C d I I 1 I I 1 REQUESTED BY THE GRID VIA CONNECTED SOLUTIONS. VISIBLE FROM APPROACH TO .I L SL --Cv- Z 8 Q RESIDENCE 60A 240V LOCATED MA SMART GENERATION METER I L _ _ - 1 I I I I I EXTERIOR ON WALL NEAR BOTTOM LUGS TO UTILITY(UNE) p0A I //�\ METERNEMA3R TOP LUGS TO L--.L1 llr'-'-'-•---'-' I I I I A 1 1 1 1 1 1 SOLAR • GENERATION(LOAD) _—' I O` 1 1 1 1 1 1 INVERTER NAMEPLATE LOCATED EXTERIOR , (-MAIN C/B T BUS a 0 .1. I I I I I I RATING 10000W/240V ® - - - I RATING I 200AG •H A f IO H I � al I ' ll ' ' A AA W I�� :, ' -A I I I I I I A L g 14.r,( e1 1< U W ACl AC2 re" AC3 _---_© I+ 11 .d a iG 1..::::::::::::::::::::::::::: �_._._.�._. (O IRA ._._ -'- (�-._. 60A © IA 6 1--0- " I�� /- _.._.._.._.._ ._ � '- -'-'-'--- - W ._._._._._ I-+ 1 '•(+ MCA ©- - -'*'-' © © ._._._._._© ©--'---'--'-'-'-.-'-.-.--'-•-._® © O J Y�Nrclwf .11- -I._,._.._..-' I , E4 I- -- E CC] G----T---0 0 (< i RI vs I:II .7' 1. EMERGENCY- • 1 I 1 I I A AL..�DlsconNER•-' I 1 I I > + + I 1 I I > BATTERY BATTERY I I I I I 4 • toyam® *� EQUIPMENT GROUNDING _ F- L METAL PV MODULE FRAMES MUST BE CONNECTED TO THE EGC 0 (EQUIPMENT GROUNDING CONDUCTOR). LI.WEERS MAY BE USED IN LIEU OF MODULE GROUND CLAMPS Q OR LUGS,WITH APPROVAL OF AIR AND RACING MFG.WEEKS J ARE ONE TIME USE ONLY.SEE'we-Ilc.com'FOR RACKING SPECIFIC WEEB,INSTALL INSTRUCTIONS,AND UI 2703 CERT. I_ J L2.FOR"LAY-IN"LUG MODULE GROUNDING;CORRECT CC HARDWARE OF PROPER METAL MATERIAL TO AVOID U 0. CORROSION MUST BE USED.TYPICALLY DIRECT BURIAL RATED, TINNED,OR STAINLESS STEEL GROUNDING LUGS MUST BE 6 CC ATTACHED AT MARKED LOCATION ON EACH MODULE. W IAH 2.THE EGC(EQUIPMENT GROUNDING CONDUCTOR)IS USED TO H U BOND ALL NON-CURRENT CARRYING CONDUCTORS AND EXPOSED 5 LL2 METAL PARTS THAT MIGHT COME INTO CONTACT WITH U U _I CURRENT-CARRYING CONDUCTORS,INCLUDING THE FOLLOWING: 0C 0 LIJ 2.1.PV MODULES FRAMES,ARRAY MOUNTING RACKING;THE N METAL CHASSIS OF EQUIPMENT SUCH AS INVERTERS, ly O DISCONNECTS,METERS, ON BOXES MD COMBINER BOXES;AND METALCONDUIT HOLDINGCIHCUIIS>250 VOLTSQ L�Q 0 TO GROUND PER NEC 250.97 O K 0 X 3.THEGEC(GROUNDINGELECTRODECONDUCTOR)ISTHE OCONDUCTOR USED TO CONNECT THE GE OR GE SYSTEM TO THEL/SYSTEM GC,TO THE EGC,ORTO BOTH. 1.OFT NARO,RING, RPLATE ESTA ASHING A DIREO&ECT, a OFTEN E(GROUNDING ELECTRODE)IS A ESTABLISHING CONNECTION TO EARTH.THE AC SYSTEM GROUND IS EXISTING, JB USUALLY AT THE EXISTING MAIN PANEL AND/OR UTILITY METER. THE GROUND CAN ONLY OCCUR IN ONE PUCE AND MUST NOT BE PROPOSED UNDERGROUND I DUPUUTED IN SUB-PANELS OR ANYWHERE ELSE ON AC SIDE. CONDUIT TRENCH LENGTH:18 FEET ELECTRICAL SYMBOL LEGEND Z ® DC COMBINER BOX ® AUTO TRANSFORMER an STOREGED BACKUP S SOLAR LOAD CENTER INTERFACE ® AC COMBINER CL MO DC DISCONNECT ® BATTERY U 0 ® DCJAC STRING INVERTER OEMAC DISCONNECT AC I ®ME CRITICAL LOADS PANEL ® SERVICE PANEL J C S RAPID SHUTDOWN © PERFORMANCE METER 0 2 N C ® SUB-PANEL ® UTILITY METER > Fe y o ® EMERGENCY BATTERY ®TRANSFORMER 0 < 1.-.- E ��\\\\\\\\ / DISCONNECT I— 0`W////// ® EMERGENCY RSD SWITCH ® (UNCTION BOA 0 01 ® CIRCUIT BREAKER ®AUTO TRANSFER SWITCH = C ryry .0 DISCONNECT ®SMART TRANSFER SWITCH a W V G SECTION RR ARRAY TAG UM TESLA GATEWAY H . Z SECTION II MilTEMA POWERWALL 1 MODULE GROUP ® GENERATOR N O O EXISTING EQUIPMENT 0 W O 18 _ W o. a 0 0 Q , .-4 Z0o O N i \ fE)GRADE a v Q v ./.\ \ j fk i B ry K Y + \./.....__>,----/X\r__________ ��BACKFILLWRH c \ ;�;� �.� NATIVE SOIL ^' \\\\.\\\ --�� PVC SCHEDULEDD� �•-12. J TRENCH DETAIL t -I SCALE:N.T.S. > Q /V\ NORTH 4!' QTY 28 REC Group REC400AA BLK MODULES QTY 1 SolarEdge SE10000H-US EnergyHub INVERTER SCALE:1/8"=1'O'@ SHEET SIZE A3 Ir 1 CONDUIT,RACEWAY,1-BOX,AND PULL BOXES y l'D" 2 DC DISCONNECTS yrSCALE: 3 INVERTER(S) y SHEET NOTES N AWARNINGo WARNING CODE ABBREVIATIONS: ELEARI AL CC WARNING: PHOTOVOLTAICCODE AB BONA IONS:NG CODEE( o INTERNATIONAL BUILDING RESIDENTIAL CODE E(I POWER SOURCE ELECTRICAL SHOCK HAZARD THE DISCONNECTION THE INTERNATIONAL BUI DIN (IBC) ) g TERMINALS ON THE LINE AND LOAD GROUNDED CONDUCTOR(S)MAY UNDERWRITERSINTERNATIONAL LABORATORYFIRE DE(AFC) Il UNDERWRITERS (UL) F- SIDES MAY BE ENGERGIZED IN THE RESULT IN OVERVOLTAGE ON THE 1.COMBINATION PLACARDS MAY BE USED IN PLACE OF MULTIPLE E -. a i. PLACE ON CONDUIT AND/OR RACE WAYS EVERY 30'(601,12' OPEN POSITION EQUIPMENT PLACARDS FOR THE SAME DEVICE.AU.INFORMATION FROM THE w 0C MULTIPLE PLACARDS MUST BE PRESENT. O. [ Q FROM BENDS,3Y ABOVE AND BELOW PENETRATIONS. 1. PLACED ON DC DISCONNECT(S)AND ON ANY 1. MINIMUMl7 OF 31/2"a 101/2" 2.BLACK LETTERS WITH YELLOW BACKGROUND MAY BE USED IN CI 2. CODE REFERENCE:NEC 690.31(03) EQUIPMENT THAT STAYS ENERGIZED IN THE OFF PLACE Of THE STANDARD WHITE LETTERS WITH RED W LL Z 3. MINIMUM OF 11/8'a53/4` POSITION FROM THE WSUPPLY. 2. FONT'.3/8" BACKGROUND WITH MU APPROVAL. LVVNIQQ��1 f a 4. FONT:3/r AND.8 WIDTH FACTOR. 2. CODE REFERENCE:NEC690.13(B) 3. WARNING LABEL IS WHITE AND ORANGE 3.ALL INTERIOR AND EXTERIOR DC CONDUIT,ENCLOSURES, j� I- 5. REFLECTIVE WHITE LETTERS ON A RED BACKGROUND. 3. MINIMUM OF31/2"410' RACEWAYS,CABLE ASSEMBLIES,JUNCTION BOXES.COMBINER W In E BOXES AND DISCONNECTS ME MARKED.(NEC 690.31(G),NEC CC a 4. FONT:3/8` 690.13&690.53) N 5. WARNING LABEL WHITE AND ORANGE 4.THE MARKINGS ON THE CONDUITS.RACEWAYS AND CABLE N SCALE: SCALE: SCALE: ASSEMBLIES ARE EVERY 10 FEET,WITHIN ONE FOOT OF ALL EM\ 4 NON-LOAD BREAK DC COMBINER/1-BOX ]/2^a 1'-0 5 DC COMBINER BOX 1/r•1'-0 6 SWITCHBOARDS y,.,,•, TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW <Ro a1 ALL PENETRATIONS OF ROOF/CEIUNG ASSEMBUES,WALLS AND ORV 0 AWARNING BARRIERS(PC 605.11.1.A,NEC 690.31(GI(3I) O 0 DO NOT OPEN UNDER LOAD DC COMBINER BOX ARC FLASH HAZARD 5.OR MEMBRANE ROOFING MATERIALS IN REEIASLA NOT ; tL COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT.THE w APPROPRIATE PPE REQUIRED LOCUTION OFERCUITS SHALL BE CLEARLY MARKED. IC 1. CODE REFERENCE:NEC 690.13(C) FAILURE TO COMPLY CAN RESULT IN 6.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR 2. USE ONION-LOAD BREAK RATED DISCONNECTION. COMBINER#1 DEATH OR INJURY THE ENVIRONMENT MATERIALS USED FOR MARKING MUST BE WEATHER RESISTANT.UL STANDARD IS RECOMMENDED TO 3. MINIMUM OF I"a 6" DETERMINE WEATHER RATING.UL CASTING OF MARKINGS IS NOT REFER TO NFPA 70E REQUIRED.SEE UL LABELING SYSTEM 969(UL 969) 4. FONT:3/8"AND.8 WIDTH FACTOR 7.MARKING CONTENT AND FORMAT: 5. WHITE LETTERS ON A RED BACKGROUND. 1 USE PLACARD"COMBINER N I"WHEN MORE THAN DC COMBINER IS USED.NUMBER ACCORDING TO W.I. VERIFY WHICH PLACARD IS REQUIRED WITH A 7.1. MIAL OR SIMILAR FONT,NON-BOLD. 11) THREE LINE DIAGRAM AND CALCULATIONS. 2. MINIMUM OF I"A 4' 7.2. MINIMUM 3/8"LETTER HEIGHT FOR HEADERS. 2. MINIMUM OF 1'v4' 3. FONT:3/B'AND.B WIDTH FACTOR 7.3. MINIMUM 1/16'LETTER HEIGHT FOR DATA g 0 LO DO NOT DISCONNECT UNDER LOAD 3. MINIMUM OF 75 T08WiDTH FACTOR 7.4. CONTRASTING BACKGROUND ANDLETTERING. Q. 0 AND4. WARNING LABEL IS WHITE AND ORANGE 7, ALL CAPITAL LETTERS. 0 .••I 4. WHITE LETTERS ON A RED BACKGROUND. 5. DATA COLLECTED FROM AS-BBUILT INFO, 7.6. CONTRASTING SPACE BETWEEN ROWS OF TEXT 0 PRIOR TO PTO,BY OTHERS. 7.7. DIMENSIONS OF PLACARDS ARE APPROXIMATE.MAY BE F y Q SCALE; SCALE: SCALE: REDUCED AND/OIL INCREASED TO UL APPROVED J C U • 2 7 MAIN SERVICE PANEL 2/r.1•a B AC AND DC DISCONNECTS y,.,,•a. 9 J$OX,DC COMBINER,AND DC DISCONNECT ix.1'-0' MANUFACTURED PRODUCT 0 m m .ce 1. LOCATE NO MORE THAN 1 m FROM THE SERVICE DISCONNT ENGINEERING STAMP(II appl.) p a E- a MEANS TO WHICH THE P/SYSTEMS ARE CONNECTED AND AC DISCONNECT 0I NOWARNINGF - C E SHALL RDICATE THE LOCATION OF ALL IDENTIFIED RAPID ELECTRICAL SHOCK HAZARD d 'q IN SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. = C V t SOLAR PV SYSTEM EQUIPPED DC DISCONNECT I TERMINALS ON THE LINE AND LOAD 3 23 , z WITH RAPID SHUTDOWN USE PLAEMDONNECTIDU USED. ER WHEN MORE SIDES MAY BE ENGERGIZED IN THE Y THAN ONE DISCONNECT IS USED.NUMBERACCORDING TO OPEN POSITION g W -. LIR THREE LINE DIAGRAM AND CALCULATIONS. TURN NAM)SHUTDOWN AILDC VOLTAGE IS ALWAYS PRESENT ZoCo Ti TO THE PHOTOVOLTAIC PHOTOVOLTAIC WHEN SOLAR MODULES ARE ¢ a o NSNTo EXPOSED TO SUNLIGHT �DOWN SYSTEM DC DISCONNECT AC DISCONNECT IS" 6"MIo PV DUCE 1. ONLY FOR UNGROUNDED SYSTEMS. Q SOAK HAZARD 1. PUCE ON ALL AC MID DC DISCONNECTS 2. PLACED ON ALL ENCLOSURES WITH UNGROUNDED CIRCUITS Y Q N PI THE ARRAY. OR DEVICES WHICH ARE ENERGIZED AND MAY BE EXPOSED to 2. CODE REFERENCE:NEC 690.13(B) DURING SERVICE r1 > 3. MINIMUM OF 1'a303/2' 3. MINIMUM OF 3'a 101/2" VI p C a" 2. CODE REFERENCE:NEC 690.SH(CKl)(A) O 3. TITLE:MIN.3/8'BLACK CHARACTERS ON YELLOW 4. FONT:3/8` 4. FONT:3/8" WI TO` BACKGROUND.REMAINING CHARACTERS MIN.3/16- 5. WHITE LETTERS ON A RED BACKGROUND.IN BLACK ON WHITE BACKGROUND. 5. WARNING LIBEL IS WHITE AND ORANGE G LL 10 INVERTER(S) in. 11 RAPID SHUTDOWN SWITCH yC.G' INVERTER# 1 1. A RAPID SHUTDOWN SWITCH SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN IRA(3 FT)FROM THE SWITCH THAT W INCLUDES THE FOLLOWING: N 1. USE PLACARD INVERTER I1"WHEN MORE THAN 1 RAPID SHUTDOWN SWITCH J INVERTER IS USED.NUMBER ACCORDING TO THREE FOR SOLAR PV SYSTEM - Q\ UNE DIAGRAM AND CALCULATIONS. N 2. THE LABEL SMALL BE REFLECTIVE WITH ALL LETTERS CAPITALIZED > / 2. MINIMUM OF I'v4" AND HAVING A MINIMUM HEIGHT OF 9.S MM(343 IN.). 3. FONT:3/8" IN WHITE ON RED BACKGROUND. A WHITE LETTERS ON A RED BACKGROUND. OlE 28 REC Group REC400AA BLK MODULES QV/1 SolarEdge SE10000H-US EDergyHub INVERTER - 1 DC DISCONNECTS&DISCO.COMBINER 1/SCALE: 2 AC DISCONNECT,AC SUB-PANEL vi.-SCALE: 3 UTILITY METER,SERVICE PANEL,SUB-PANEL 1/SCALE: SHEET NOTES LC) AC DISCONNECT 81-INDEPENDENT/SEPARATE CODE ABBREVIATIONS: 0 PHOTOVOLTAIC SYSTEM PV SYSTEM AC DISCONNECT PHOTOVOLTAIC SYSTEM WARNING NATIONAL ELECTRICAL CODE(NEC) CC PV SYSTEM DC DISCONNECT DC DISCONNECT RATED AC OUTPUT CURRENT 42.0 AMPS AC DISCONNECT INTERNATIONAL BUILDING ALCOOE CODEBC) Q MAXIMUM CIRCUIT CURRENT 45.0 AUG roxa.*Tcwert a O. AC NORMAL OPERATING VOLTAGE 240 VOLTS IA POPs DUALc POWER SOURCES H INTERNATIONAL RESIDFNTIN. (IRC) U RCNORWLORMRY WVOL w VOTs AMPS UNDERWRITERSRONALL FIRE LMORA CODE (IF) MAXIMUM VOLTAGE NO HOC ISVRSBL VOLTAGE m VW nc HoxNu oPeuiaO VOLTAGE AO NORMAL OPERATING\GLMAGE HR VOLTS (- STRINGINVERTER*I-INTEGRATED AC DISCONNECT 11 - PV SYSTEM AC DISCONNECT PHOTOVOLTAIC SYSTEM • S.PLACARDS FOR THCOMBINATION EE SAME DEVICE.ALL INFORMATION FROM ARDS MAY BE USED IN PLACE OF LE WC. U BUILDING CONTAINS TWO SOURCES O. C PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT 42.0 AMPS AC DISCONNECT OF POWER:UTILITY,SOLAR PV THE MULTIPLE PLACARDS MUST BE PRESENT. ,sY L PV SYSTEM DC DISCONNECT AC NORMAL OPERATING VOLTAGE 2N VOLTS UTILITY SERVICE DISCONNECT LOCATED 42 2.BUCK LETTERS WOE YELLOW BACKGROUND MAY BE USED IN Q DC DISCONNECT Mi® WN HES VM IC BELOW.SOLAR PV SYSTEM DISCONNECT PLACE OF THE STANDARD WHITE LETTERS WITH RED W . 2 MAXIMUM CIRCUIT CURRENT AOC#2,45XOIO4RAMNNr AC HORNFLOP,3MM*AFVITAGE w vlMs LOCATED[N/E/SAN]WALL OF BUILDING - STRING INVERTER 82-INTEGRATED AC DISCONNECT BACKGROUND WITH AVEAHI APPROVAL. MAXMUM VOLTAGE HOC SLOWLY VOLTAGE VOL 10 0 - PV SYSTEM AC DISCONNECT PHOTOVOLTAIC SYSTEM 9.ALL INTERIOR AND EXTERIOR DC CONDUIT,T,BOXES, , W m RACEWAYS,CAME ASSEMBLIES,JUNCTION BOXES,COMBINER &I RATED AC OUTPUT CURRENT AMPS MT®AC DISCONNECTOCO BUILDING CONTAINSBOXES AND DISCONNECTS ARE MARKED.(NEC 690.31[E][3], - AC NORMAL OPERATING VOLTAGE VOLTS SOURCES OF POWER:WER: NEC 690.31(E)[41 L 690.53) ON AGHORAAKOPERATING In VOLTAGE UTILITY.SOLAR PV PRPHOTOVOLTAIC SYSTEM PV SYSTEM DC DISCONNECT UTILITY SERViCE DISCONNECT 4.REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR MID DC DISCONNECT AC SUB-PANEL RI LOCATED BELOW.SOLAR PV THE ENVIRONMENT.MATERIALS El USED FOR MARKING MUSTTO E Q� N MAXIMUM CIRCUIT CURRENT ADC #3 wt.ancurr ARAOLTw®G SYSTEM DISCONNECT LOCATED WEATHER RESISTANT.UL STANDARD IS RECOMMENDED TO MAXIMUM VOLTAGE VI1C AMVAM VOLTAGE WC PV SYSTEM AC DISCONNECT PHOTOVOLTAIC SYSTEM [WE/SANI WALL OF BUILDING DETERMINE WEATHER RATNG.LACASTING OF MARKINGS IS �.N�- 0 RATED AC OUTPUT CURRENT MPS AC DISCONNECT NOT REQUIRED.SEE UL LABELING SYSTEM 969(UL 969) o 0 - AC NORMAL OPERATING VOLTAGE VOLTS AMPS RC n �T . 5.MARKING CONTENT AND FORMAT: 1.UPPYLBCARD REAKERLACPDAT MAIN ERGO NERTICE ON,(*2 DISCONNECT/BREAKER D PV SYSTEM CL SUPPLY BREAKER AT POINT OF INTERCONNECTION.(M2&83)PLACARD(S) 5.1. ARIAL OR SIMILAR FONT,NON-BOLD. IRA REQUIRED WITH 8I PLACARD WHEN UTILITY SERVICE AND PV SYSTEM DISCONNECT(5)ARE 5.2. MINIMUM 3/8"LETTER HEIGHT FOR HEADERS. CC NOT LOCATED NEXT TO EACH OTHER.MAP PLACARD REQUIRED AS SPECIFIED. 5.3. MINIMUM 1/16"LETTER HEIGHT FOR DATA 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 5.4. CONTRASTING BACKGROUND AND LETTERING. 1.PLACARD PLACED ON EACH DISCONNECT,IF MORE THAN ONE PRESENT. 2.1.VALUES WILL MATCH LOAD CENTER OR SUB-PANEL VALUES IF INSTALLED AFTER 5.5. ALL CAPITAL LETTERS. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. INVERTERS.IF AC CONNECTION TO SERVICE PANEL COMES FROM INVERTERS;SEE 5.6. CONTRASTING SPACE BETWEEN ROWS OF TEXT SHEET"E-001/STRING INVERTER[*)SPECIFICATIONS". 5.7. DIMENSIONS OF PLACARDS ARE APPROXIMATE.MAY BE SEE SHEET'E-0Ol/DC DISCONNECT[*)" 2.1.1.INVERTERS ARE PARALLEL CONNECTIONS. REDUCED AND/OR INCREASED TO UL APPROVED 3.CODE REFERENCE:NEC 690.53 1.PLACARD PLACED ON EACH SOLAR DISCONNECTINGCOMPONENT. 2.1.2."RATED AC OUTPUT CURRENT"WILL BE THE SUM OF THE INVERTERS MANUFACTURED PRODUCT VI 4.MINIMUM OF 21/2"x8"OR 5"x 2 1/2"RESPECTIVELY. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.3."AC NORMAL SPOUTING VOLTAGE"WILL RE THE NAME PLATE RATING OF THE 6.ANSI 2535.4 PRODUCT SAFETY SIGNS AND LABELS:THIS Z SEE SHEET"E-001/AC DISCONNECT(N1" INVERTER INFORMATIONAL NOTE AND ITS REQUIREMENTS FOR PLACARDS 5.FONT:3/8'HEADER,3/36'DATA MAY BE USED WITH PRIOR APPROVAL OF THE WEE MOSTLSO 3.CODE REFERENCE:NEC 690.54 3.CODE REERENCE:NEC 690.54,NEC 705.32(BN3) a. C 6.WHITE LETTERS ONA RED BAIXGRWND. NOTABLE WRITTENDIFFERENCES IS COL00.OF PLACARDS AND USE OF 4.MINIMUM OF II/2"x81/2"OR 13/4"x 61/2'RESPECTIVELY. 4.MINIMUM OF 2"x 61/1"(*1),VARIES(*2883) _U 7.IN SOME CASES TWO LABELS MAY BE REQUIRED.AN INVERTER WITH INTEGRATED HAND VALUES WITH INDUSTRIAL MARKERS ON 0 DC DISCONNECT UTILIZING TWO MPPT TRACKERS:IF CONFIGURATION USES 5.FONT:3/8"HEADER 3/16"DATA 5.FONT:3/8"HEADER.3/16"DATA(81),1/4"(82&*3) STANDARD PLACARDS WHERE THE VALUE MAY CHANGE AT A Q 4) Q I- DIFFERENT MODULES. 6.WHITE LETTERS ONA RED BACKGROUND. 6.WHITE LETTERS ONARED BACKGROUND. FUTURE DATE.I.E.ADDING MODULES AT A FUTURE DATE,OR C J 2 STANDARD PLACARD MANUFACTURER INSTALLED ON ELECTRICAL COMPONENT.AVE APPROVAL REQUIRED.(SEE O `O N C 4 MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER OF NOT SAME LOTAnoN) SCALE 1-0. 5 MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER(IF NOT SAME LOCATION) 1/2�a„ NOTE 81 FOR INDIVIDUAL PLACARDS) > ` iir ¢ . 04-, 0 0. (WITH COMBINED WARNING PLACARD IF REQUIRED.EXAMPLE:LAMP) 0 w i 1. PLACARD PLACED AT ELECTRICAL SERVICE AND AT THE PV 1. PLACARD PLACED AT ELECTRICAL SERVICE AND AT = C V tt CAUTION 2 MAP INVEPLACARDPROEAER AND PV N ANDINERF NOT AT ORYOFTNEF RViCEDCATI°N CAUTION THE SAMETHE PV VIOCATANDPVDISCONNECSIFNOTAT a 01 N O DISCONNECTING MEANS AND PHOTOVOLTAIC SYSTEM 2. MAP PLACARD PROVIDES A DIRECTORY OF THE """ Z DISCONNECTION MEANS. SERVICE DISCONNECTING MEANS AND POWER TO THIS BUILDING IS SUPPLIED 3. CODE REFERENCE:NEC69056(AXB),705.10 PHOTOVOLTAIC SYSTEM DISCONNECTION MEANS. p U2 n FROM THE FOLLOWING SOURCES WITH 4. WHITE LETTERS ONA RED BACKGROUND. POWER TO THIS BUILDING IS SUPPLIED 3. CODE REFERENCE:NEC 69L1.56(A)(B),705.10 CN ¢ d 1,1 DISCONNECTS LOCATED AS SHOWN: 5. MINIMUM OF 7 3/4"x 5" FROM THE FOLLOWING SOURCES WITH 4. WHITE LETTERS ON A RED BACKGROUND. ti Z 0 0 a 6. FONT:3/4""CAUTION",1/4"WARNING",3/16"HEADER, DISCONNECTS LOCATED AS SHOWN. 5. MINIMUM OF61/2"x63/2" Q 1/8"DATA AND NOTES 6. FONT:3/4""CAUTION",1/4"HEADER,1/8"DATA AND NOTES eMyy SOLAR ARRAY 7. PLACARD WILL BE PLACED ADJACENT TO THE MAIN SERVICEO,p DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE SOLAR ARRAY 7. PLACARD WILL BEPLACEp ADJACENT TO THE MAIN M C INVERTER ON ROOF TOP THE DISCONNECT IS OPERATED.(IFC 605.11.1.3) ON ROOF TOP SERVICE DISCONNECT IN A LOCATION CLEARLY p W/DC DISCO INVERTER VISIBLE FROM WHERE THE DISCONNECT IS W/DC DISCO STOREDGE BACKUP OPERATED.(IFC 605.111.3) r4 j INTERFACE STOREDGEPB P CC •rtl EMERGENCY BATTERY RAPIDISCD O EMERGENCY NM ECBATTERY T&RY M NAPIDSHUTOOWN -`/ C Q SWITCH RAPID SHUTDOW `/ AC DISCO [ SOLAR ARRAY SWITCH IYI M AC DISCO SOLAR ARRAY RESPONSIBILTTYNOTES LL PRODUCEION 11,= �,/" R0DUCTON •L:ay-A o ON ROOF TOP METER '\ ' I METER *� ' L PRIME COMRACTOA/PERMIT APPLICANT SIGNER lTiIUTT'METER 6 * IL 1� UTILITY METERS *.IL1 �L, I`� FS RESPONSIBLE FOR THE DESIGN AND `} SERVICE PANEL R,0*igitkk ``,,I\\,I SERVICE PANEL- ILT�LTLRO0,L\�' 1f� SPECIFICATIONS OF THE PHOTOVOLTAIC SYSTEM / INSTALLATION PRIME CONTRACTOR/PE BATTERY ‘4BATTERYN APPLICANT SIGNER WILL BE RESPONSIBLERMIT FOR W WARNING COLLECTION OF EXISTING IONS INFORMATION REQUIREMENTS TO DESIGN,SPECIFY,EOFT,AND INSTALL THE EXTERIOR MOUNTED PORTION OF THE . ELECTRIC SHOCK HAZARD-DO NOT TOUCH TERMINALSq DOCUMPHOTOVOLTAICSYSTEM DETAILED IN THIS L TERMINALS ON BOTH THE LINE AND LORD SIDES DOCUMENT. MAY BE ENERGIZED IN THE OPEN POSITION 2 ADVANCED SOLAR SOLUTIONS,INC IS RESPONSIBLE FOR APPLYING SUPPUED INFORMATION INTO A SET OF PERMIT DRAWINGS.ANY CHANGES TO DRAWINGS ARE SUBJECT TO CONTRACT LL CONDITIONS BETWEEN THE CLIENT AND ADVANCED SOLAR SOLUTIONS,INC.IN ACCORDANCE WITH THE REQUIREMENTS OF THE Pr AH PV MODULE CUT SHEET ci'1 I-- Lu Lu 2 V) • SOLAR'S MOST TRUSTED le REC -.-` REC PRO'I�UET SPE:1-If r- IO'NE 2 SOLARS MOST TRUSTED 0 U CC o - 2.5171.h4.11 .3 0 -k . .•• 0 I Lt6'215.2016.0-,61730.201%U'_41730(Pendurg) I LKJ 7ja: C14002004,1509J215,O159 120D].(C6I1 lt fu3l N a 0 d� O mi+.0m1 Q c-IWARRANT)) g g. .41 ® S Sta4.3 KC ProTnat Ce NstalNdbyenPECCut6ed W Yes ves 1144. & 5o191115ssbre z i144aw41; i- System Size Ad 4251de 25300kW (�-�� PI.WOIWanany(yrs) 20 25 25 zazaas( '` Powe-Warranty(yrs) 25 75 25 i4 - [ans44n2 I� ' 17oo tat.7. ,, Lam-Warranty(yrs) 0 25 10 4 �� \\\ _ _4 ;' Power N Yearl 90% 98% 98% Amwal Degradatbn 0.25% 025% 0.25% . ...._4 0% 2 5 .<oase�s,,,s.re,,,, 2is[o.o1 ~- :3¢A4.ao.1SL._._ pu vusuYnrnuee %foro-92% 92% Z mnhi a4N21 c u en+C.ra,bmequy GE/ERALDATA d O 1321,10.-us RFC heter•Taic-M[91 StklAskeC4PV.3T4/K5T4.12AWG _ O h-en>t Operubna;tempe.atNe <0-.•IBS•F(•40...-BSY) U 0 O Cell type. vetnkad4rae,gapkss athncbgy Connectors «cra+.awu+iE<6265: Max mum system voltage. 1000V Q Q 6.trtgs or 22MS In swim ,e 115seNy..henrrm.trd W Max,mun test bac(fro-t): •7000Pa(1466s/sgk J C U 2 013.13.2mm)solar glass with 12AWG(4.mrna)PV,W443.47N0I.12m1 O Glass: Cablo anrv-46ecmn surface traasmenz aeo.a..ewtnk%Sm�le Max mumtes[bac(read. -400uPa�3S bs/sg Rl' Y Max series fuse rat'.s/ 25A o Q !e Backsheet. Highly resistant polymer(bWd) ONlembm'. /1./x{04I41(1821aIU16A30mnd g I- E Max reverse current 25A E I- -O C E Frame: Anodleedehunkwm 1pWck) Weight 456s120.5 kg) ,ere urn:anm.weire� ,neib.c Q [0 REC ALPHOC® PURE m4 4.. euomavePp�e�PiC4.�b;�/ ��facwl _ L v[n^_n Mx apart ibypess N4dez,IP6)rated Or;gi-. Made in Smppme V �.accna«ee+.e•IE.62Ad • 1 N .H O w4,w 3 Z BLACK SERIES 8=�lassSo 41-(WPI 385 390 395 IOOI 105 Nu tM:d kOpe aceg mgaasue H'C(aYCI O tad w N Z Watt Class Sorting- G/•5 0/•5 0/•5 0/•5 0/•5 Temperatue wefi<Nn;of P;,,a: -0.Z6%w R N Q C CC 0. Nominal Power Voltage-Vw.iV) 4L2 11.5 II.B 42.1 12.4 Temperature coefficient ,: .024%/'C ay 2 0 as NomNal Power Cwr,t-1,r,.(A) Y35 9.00 9.45 9.51 956 Temperature menden)of 1,� 004%/•C �g Q Q PRODUCT SPECIFICATIONS -Open CbwdVoltage- (V) 48.5 48.6 48.7 48.8 48.9 1""eeperatw..,.fikknr,.taeea.ekM«eaue. ShortOrcuI1Curent-I.,IA) 9.99 1003 1007 10.10 l0M p W Rwe-Censtty(W/sq R) 19.3 19.6 19.8 20.1 20.3 urm..tr-u*....fruwm < '71 0 p .. _ ParulEfficienry)16) 208 211 213 21.6 219 Typical owlrra4bncepMm'manceolm:domatSTC: - •'-I > 2 u40t Pewe-Qitpu:•P,wa(WPI 293 297 30I 305 309 i O +ma Nom6alPower Voltage-V,„,(VI 3E8 391 39.4 39.7 400 V C < gf iNom8alPower C m (.0urrent-I,a„(A) 7.55 7.59 7.63 7.68 772 F .� O EXPERIENCE Open ClrcudVoltage-V... 45.7 45.8 45.9 46.0 45.1 . . LL $hortacW¢urrent-(i(A1 8.01 8IV 813 e16 8.19 bNnwryl/n'�- VAasneoar:eacmdue.RTcr+.aANIS.Nwa.on75 WyseflIMCVAI,wm..ue72F25q hwdmpmn'r ..n. rarcoS13 v,41.:3..M.w ,ww cna�l fan A.1.11-at+.lek-4eaaa0M'ma-e.: w445.wa / w/m tenruee.•rae12sc1++dPwdi3M11.04. n+eu a ilemn.. ame ff',. na Ja. cae. JEou-ded N139fi,AEC Groupn an nternatbna pb,NeNma Soler energy REC O 11 :ompany dedicated tom e-powerne consumers with clean,aeorcabk LEAD-FREE 41[r p4 AS So ari Most b n m n Trusted,REscom mtteegnq,ay. then and a law catboat footprint'A the s4'.ar materials and solar wmvrecg-uup[um panels It manufactures Headquartered 1n Vo-way with ope'a.onal 6 E11GE9LE ROHS COMPLIANT PERFORMANCE eadquarters N Singapore,AEC also has regbnal hubs inNo•th America. > > Europe,and Asia-Pumc. INVERTER CUT SHEET V) I— w Single Phase Energy Hub Inverter N with Prism Technology 2 I For North America .... a Single Phase Energy Hub O SE3000H-US/SE3800H-US/SE6000H-US/SE7600H US/SE10000H-US/SE11400H US(') a LL ~ a I n ve rte r with Prism Technology SE3000H-US 15E3800H-US SE6000H-US SE7b0oe-us SE10000H-US SE11400H-US UNITS L.N W OUTPUT-AC ON GRID For North America RateeACPcxe UJ eW @24Y W J�.4V �, »4 �2<°° w o 3300®20BV SW00208V 100000259V SE3000H-US/SE3800H US/SE6000H US/SE7600H US/ T Mvm:mACPaw_0rtP4 roo 3012V 50024W 3300®209V 5,100208V 7600 10CM 1d0502M'V 100.100209V w Qo� C) SE10000H-US -US('I ACFepueryRan3e0n-non-ma-0 593-60-605 4 CT7 Murouns Ccixncus Output Current Q 240V -5 6 5 -' 4 <75 A Maximum Ccnenuas lAtpu CurCurers•20BV M :4 185 A W CC GEN Threshold 1 ACC 12-25` Tow HenmwD•000.1(ORA <3 66 I A •,- he, 1.adjustable-OM• VEM 1 I:Ijnniny%<atior5eou0.ry ea-�fguraderrc.�hobs Yes \WARRANTY./ r -� T - -. r„e,c AC rak+wedl Y. OUTPUT-AC BACKUP. N • • _J Nee AC Pew.,8alwp Ope,4,n• 3600 6 7600 C0 17600 10SI0 'J:-0C W .] G e# ACI-0gp,2Acl Voltage gAarge in Ba,F�p 2n-26a Vac () I . ACI-N Prtpt Vchage Rage n 9aciuw 135 211-264 Vac Q O • ...MT .JD • AC 1e:sleny Ra,yein Bs_kp(fmn-nun-mad -0-6. e5 Ha J C E 2 - co M..x:'nuin Cv O 40eassaput Current in8s:tup Operation 12.5 - » 25 32 42 43 A 0 O` F-f C 32' 43' e GO 1 A 0 . n • Tlln 45 k I— -0 C OUTPUT-SMART EV CHARGER AC 0 .0 2 • • 70-264 Vx: Vs .IN -s Z WO - ..(r. .,/12..-- _--_ 83-61-62.5 IIz Y VVff 51' o O V1 N INPUT-DC(PV AND BATTERY) N CC CC Z Q a Yes .~-I Z , Q Optimized battery storage with HD-Wave technology MalnputVokage 4so Yd, a Ncm DC Input Voltage 380 Vdc / Record-breaking99%weighted efficiency with /Multi-inverter,scalable storage solution Reearsx-PJatyProt � Yes o a GrrouMiarkbc♦a Deter g 200%DC oversizing / With enhanced battery power up to 10kW INPUT- 6wEose'er ta" << v o .m. ,- ¢ m /Small,lightweight and easy to install Maa,m,m DCPca.erO 24:V 6000 7503 12�000 'sxo 22000 226Cc W /Integrated arc fault protection and rapid shutdown 152C5' 22e07' ''4 z ui En- for NEC 2014,NEC 2017 and NEC 2020,per article Maalmnm lac P.>wer 0 203V - 66:., 1^000 - - :POW W 'C' a Modular design,future ready with optional 690.11 and 690.12 :0.11 20 ro Maximum Input Current,0241V 85 16.5 27 31 Adc upgrades to: 20' 31' LL / DC-coupled storage for full or partial home backup /Embedded revenue grade production data,ANSI Maainau"mPu°^ ®208V - - 13.5• - - 27 AO: / Built-in consumption monitoring C12.20 Class 0.5 Max Input Shut crwCurrent 45 Aa< Maximum YAertg Mercy 99 I 99.2 96 / Direct connection to the SolarEdge smart EV se 0240V charger ctc waglacd Efficiency 9593.5 ezaav 2b"le Di>tmre2m Yes O :ecoz.md with PSSrnscH.048 ..orSEoa0,5eNelosso M _£ J lit nwee,pec&au na apt1/1u^wrenm HP pr pen.um .FmOH-USsIOn or 1FuuN4.Snpm r a ar, N nrati c un Ns model nun.'IXn1P1u_n-HM-Le Al nc,40, ragas!uWgs Pkos:<mua Sraafbpe suFycrt 01 Rol desk,. Ar sbnze aepk m a9.cne era novo.AC formrna01Hno.B6.0,6 ArcarrAn n see,. *see 2auoc'A N• 14)Read As.mar in Bei,P Opera.are rein 1Pr m;oNerms rm rook*owe.e.For aunplab-Nzp Imatr omen°n nod ACpemr m B&3 o is IOn d CRMue row , solar_ A6 r<u current smq be aoi inverter km io np ecum..MN es staled solaredge.com I 9 z > 1 INVERTER CUT SHEET V1 I— Single Phase Energy Hub Inverter UJ with Prism Technology v) For North America a U SE3000H-US/SE3800H-US/SE6000H-US/SE7600H-US/SE10000H-US/SE11400H-USI1 g a CC Da N u-i sI:F.{g.E..c.)y Bark IC Pm Prr-.,,.v rg N UP to 35olarEdge Energy Bank up to 2 LG REAL Prow taa 0 Cmti+aws P•tY.... 6000 7600 1000.0 W o N N Peak Ppwer ._ 7600 100P9 w 0 Mdw ant C x . _ 20 26.5 Ado 0 e61 Ye; CC SMART ENERGY CAPABILITIES W rF Butt-in" CC F:...iP -r Wn8.tka,p Inte4a:e(purctav_M separately)for semce up to 3338:Up to 3 inserters Drect:pone...onto Smart EV charger ADDITIONAL FEATURES Supported Communee8orr,(raffia:es RSa55,Etter net.CeMard,WoFi(optioruD$darEdge Energy Net(opt1.n<0 Revenue Grade Metering.ANSI C12.25 BUR-in. Mtegratai AC.DC and Comrtune32.C0nn:to:o Urnt Yes N loerter Commas/ming Wah the SetApo math appE'atunusig bulo-in WwFi Amass Port for B.106re166 DCVc i.rgo Rood A'utl-x.•r(PVOMB0tery• . Ws.xoordlrg to NEC20l4.NEC 2017 and NEC 2.20690.2 STANDARD COMPLIANCE Ruleo Sr d analUi74i5A ULt]at xSDL1699d UL1:gB,ULir1J,CSA 222 Q O EEE1547,R 2t RuB 14H a E n s_i.r. FCC part 15 dossB J C N INSTALLATION SPECIFICATIONS Q 2e AC Output and EV AC Output Conduit Sire/AWG Range 16manrnum/1a4 AWG O Q ' .2 DC Input(PV and Battery)Conduit Sag/AWG Range 16 maximum,14-6AWG F— c E mx1l6x62: Q N 450r370 r17a = C A L Denensons wth Conn.-ton Unt(Ha W/D1 17.7/16.6x 6.8/45n x 370 x174 t77r1a.6r68/ 17.7r14.6e5.6/a5^x370x174 irk/min d -Y N O 450e370 r174' 3 H - Z 26/11.8 Weight sat Coeoe a otlni 25/11.8 302/13.7a 302/13.7 E/kg - tn rn Noise <25 <25 <50 dBA 0 2 z 5 Zn Caring Natural Coowotim ti Z O a a CI Operating TemperaturcRarge -SO b.1e2/-PO te.60. T/'C a a Protection Baling NEMA a BP,Fat rumbas SE.olleArMem spin ww.the SalaldPe ilerg Bat Re Fen rumbas SFmeoUSdMus.support both S4&EEge Ervq'lb.ad W PM Prime batteries p rq w RequIty nportiq uaevtn fnnwarc LWyF !1)dsiseme..r.kn senn lc.30O rated AC pees 0*1 0ad ba'up seek.. a B,To r,, -enme..:naxvrQrnrers9nel.:me.sops-antesu,SPL-L'SIFi-20 a SFARJ7vL0.0.ib unas per nce Fmue on.nelei9 is aY b erne:�m mom. 00 'rrr V p'.m..,rvym,M pap twos lame Arrrdt.re'na,dtM in are Mewl,in t a to day FA rawer up to re Senn S7C/'T<-F:ear orner.S..,recension rub o Min...mired.snvxeVbLlAkYs+e^Maure4a+ens......1 N E. tp 7n o c a e m u" 0 W J J awselplea:r i.a1e �s.ew.ennui..sousocr.sVtlen.er,,,.swad am a w.ea.n.nerer.. ROHS E� �..nweeaa.m.,na e.m Data 105.060311FwraSww.e,a-w....wemem DC/DC CONVERTERS CUT SHEET N H W Power Optimizer N S44O S5OO ~ H 2 Power Optimizer a U O INPUT p d Rased Power' me sin w LLI Aeal.ne Ma eom lnw[Vdlave Nor) 60 VticLi- D 544O,550O MWi.^.pnaa•gRay B.6 , �mCC Ma+rum ShortCicF1 C�+bni ale cl C;mec ax R Mxile to 5 Ak Lst CCN W Mmx•Mm Dicer, 9S S Wxrltetl Etficertj 9a6 N MOven AD erx xy s o OUTPUT DURING OPERATION re Q.p en nw.-„mom c,..[.n Vr 0 p Maxim,CL:a:VOhage VV x O r{ OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) 25 VYetsO.Nu[:dag w Fcm-Oars., ) I ) w z YEAR O STANDARD COMPLIANCE Cr WARRANTY KC KC Ran 1'CUss B IFC61000.6-.',IFC61Oplfi-3.CISOR11,FI.-r50, WO teeny EC62109-1 loss II:eferyl.utt]at Me[eVt Ut9e V-O,UV reave,n Roe Ves Fire SafetyVCF-A6-F]1WA-nl-..?O'1.3-05 PI _. INSTALLATION SPECIFICATIONS Mmnum Fla.N Srsem Vct9e %100 Rm Ln wegnt lrxxd, [zuksi 6S5"1> p.q O InM Connector MCa+ d O - Input wire ret000 C I t..) N a�t Q aw„wire[eyR e mBmterF�,eRa . o Ro[xevl Rang IC68 NFNA6F > Q W O adaare SUE.) S arJ[M bw.L-F-w..M.,eac... ..x...r',arm cc V. O e.,aaea sr, a, e4',eIn,O ce. ene.ras"ci:ra.�s.+='viceoF.+..e Pee .r..a...<o,-caea1.�w.a„b.aeeaes I— 'a+ .> E I c u f a. W NI PV System Design Using a SolarEdge Single Phase Three Phase for in "I Z Inverter ND-Wave Single Phase I Three Phase 277/480V grid 3 (NWT .1) swa sir• 0 vs, vs Mu Saxg terom(Fa e,OWmlzn:, - _.— rN W CC C S RMa Nominal Faso P 56,98 U. l SbC I..t G Jr ti Z PV power optimization at the module level x,aaei5.1,<UtteatttengRn0,0.11 n, e a a ,,s IbeaN.p lea,u,n;:�.,Mtm,.ell„m,/,r; / Specifically designed to work with SolarEdge I Detects abnonnal PV connector behavior, ei p alb...., ;MI.., tP.aw eat K%w n w residential inverters preventing potential safety issues -•j'+-mesy, >.uU..,w +-•.,«.xneu h 4 9 0 mi y ¢ / Superior efficiency(99.5%) / Module-level voltage shutdown for installer and ire > f '^ firefighter safety .5-, u o.-i / Mitigates all types of module mismatch loss, c from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization \ °: Wi -=-n t'--- - - --CF: m Q LL / Faster installations with simplified cable I Compatible with bifaoal PV modules IMAM - " - managementa nd easy assembly using a single bolt Y , EE.r• J N �,` d JJ solaredge.com solar S r "_" o" ""IK",""11 i'nc-.°"'°"".,awed°°` °."NM'........1. CC RoHS ' / 1v RACKING&RAIL CUT SHEET t) I— W w Snap rack UR-a° SnapNrack Ultra Rail System N Solar Mounting Solutions UR-60 A sleek,straightforward rail solution for mounting solar modules on all roof types.Ultra Rail j Ultra Rail features two rail profiles;UR-40 is a lightweight rail profile that is suitable for most geographic w V regions and maintains all the great features of SnapNrack rail,while UR-60 is a heavier duty rail w profile that provides a larger rail channel and increased span capabilities.Both are compatible W° d with all existing mounts,module clamps,and accessories for ease of install. w m CC, W The Entire System is a Snap to Install0. o •New Ultra Rail Mounts include snap-in brackets ,n for attaching rail �" a o •Compatible with all the SnapNrack Mid Clamps and End Clamps customers love W 11 •Universal End Clamps and snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management Z •Open rail channel provides room for running in wires resulting in a long-lasting quality install U o CC •Industry best wire management offering Q , Clamps,cludes JunctMLPE n Boxes,Universal Wire 0 0 Clamps,MLPE Attachment Kits,and Conduit O Clamps 0 P- n •System is fully bonded and listed to UL 2703 ~ v_ 5 E Standard I c 3 r The Ultimate Value in Rooftop Solar an , Z O an an Lai N W Z Industry10 leadingWire Mounts available for all Heavy Duty UR-60 Rail < o o `< I//^ •UR-60 rail profile provides increased span Z , Q —T Management Solutions roof types capabilities for high wind speeds and snow loads S g •Taller,stronger rail profile includes profile- a e Single Tool Installation �., All SnapNrack Module specific rail splice and end cap ( Clamps & Accessories •All existing mounts,module clamps,and � v m with accessories are retained for the same great o v are compatible install experience g both raiil profiles LL Quality. Innovative. Superior. o SnapNrack Solar Mounting Solutions are engineered to optimize material use and d RESOURCES snapnrack.com/resources labor resources and improve overall installation quality and safety. > Q DESIGN snapnrack.com/configurator 877-732-2860 www.snapnrack.com contact asnapnrack.com , WHERE TO BUY snapnrack.com/where-to-buy RACKING&RAIL CUT SHEET 1/1 t W DESCRIPTION: I DRAWN BY: DESCRIPTION: DRAWN BY: n �I I SNAPNRACK.UR-40 RAIL mwatkins SnapNrac�3' SNAPNRACK.UR-40 SPLICE mwaticins �u u© , ��Qn ~ H M _-_-. REVISION: _ _..- --- ---._ — ; REVISION: ---- - a U PART NUMBER(S). PART NUMBER(S): 0. rm+.in '�— A ' wcn1410NM .ruus1Mo '�"" W LL d 232-02449,232-02450,232-02451 I 242-01213,242-01214 Wp_ V,. .w� Cf W cc� W N IN W N UR-40 RAIL / a w 1/1 PROPERTIES o 5 0 4-4 SKU I FINISH / - 0 232-02449 MILL 232-02450 CLEAR -�/ / //�/ > 232-02451 BLACK / ' % y i% a_ o / / d ma / a /ado+' t c 1 2 / 1.500 .,',--2------ el / �� O 2 d C ' .750 �/ 0 i l31 O E ;^-(�1f�al o . C k \' • / ///� yr N 2 .832 i% i '� Zoo SECTION PROPERTIES 1 �/ / "') S a 1.624 ` O ,p�i m Ixx 0.125 n4 CENTROID ,T 2 lyy 0.1321rrr // > ¢M Sx(TOP) 0.150 Ina n 792 , /! Sx(8OT) 0.158 In9 PARTS LIST c e Sy(LEFT) 0.175 Ins ITEM QTY DESCRIPTION r° ' Sy(RIGHT) 0.175 In' I 1_ 1 SNAPNRACK,UR-40 SPLICE TAPPED PRC,CLEAR 2 1 SNAPNRACK,UR-40 SPLICE THRU PRC,CLEAR 3 2 ISNAPNRACK,SNAPLINK BONDING CUP,TYPE 2,STEEL W ALL DIMENSIONS IN INCHES I I 4 1 BOLT,FLANGE,SERRATED 5/16IN-18 X 1-3/4IN,SS `m MATERIALS: 6000 SERIES ALUMINUM OPTIONS: ,MATERIALS: j 6000 SERIES ALUMINUM,STAINLESS STEEL OPTIONS: , --1 DESIGN LOAD(LBS): N/A CLEAR/BLACK ANODIZED DESIGN LOAD(LBS): I N/A CLEAR/BLACK ANODIZED a ULTIMATE LOAD(LBS): N/A MILL FINISH ULTIMATE LOAD(LBS): IN/A j TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 144 ! TORQUE SPECIFICATION: 412 LB-FT ICERTIFICATION: UL 2703,FILE E359313 BOXES OF 8 CERTIFICATION: I UL 2703,FILE E359313 I I ill WEIGHT(LBS): 5.85 - _ - WEIGHT(LBS): 10.52 --__-- -_ / RACKING&RAIL CUT SHEET H Lu DESCRIPTION: DRAWN BY: DESCRIPTION: DRAW wN BY: I _ SNAPNRACK,UR-60 RAIL mwatkm 1rs np J 77s SNAPNRACK,UR-60 SPLICE mwatkins �nap�rac A N j REVISION: ` _. REVISION: 'PART NUMBER(S): I PART NUMBER(S): y U 232-02481,232-02482,232-02483 ~ NI w,.aco '! 242-01270,242-01271 • rr.. �.�.,r..., w a .. 10U a ,dSE> ..a. _gym.....aE02 = UR-60 RAIL „+ PROPERTIES //' �� W N SKU FINISH /� ¢ t0 232-02481 MILL O 232-02482 CLEAR G. -- �� . 232-02483 BLACK / -/ �� t--0 -1.500 / / y 750 // % �7ry /r�� 5 o to i43, „....„...„2...„,-",-,,,,.., tL` o o i i y o o 82 �� 1.231 ( '-1 i 0 1 A I / ;, , z I / s Y 2.250 1 SECTION PROPERTIES 1 CENTROID O T. S A 0.515Ina 1 (/' (11 < v � M box 0.3271n4 I , `� lyy 0.181 In4 1 Q m Sx(TOP) 0.2701n3 1.039 ("I R 8 ; li I � PARTS UST g v? Sx(BOT) 0.315 in; ITEM QTY DESCRIPTION 11 Sy(LEFT) 0.242 in3 1 1 BOLT,FLANGE,5/16IN-18 X 3/4IN,CLEAR,SS Sy(RIGHT) 0.242 Ins 2 1 SNAPNRACK,UR-60 SPLICE,SLEEVE,CLEAR/BLACK I 3 1 ISNAPNRACK,0-RING >- ALL DIMENSIONS IN INCHES - _ 4 1 ISNAPNRACK,UR-60 SPLICE,BONDING BRIDGE W MATERIALS: 6000 SERIES AWMINUM I OP IONS: MATERIALS: 6000 SERIES ALUMINUM,STAINLESS STEEL I OPTIONS: 1 -A J DESIGN LOAD(LBS): N/A CLEAR/BLACK ANODIZED DESIGN LOAD(LBS): FULL UR-60 RAIL CAPACITY j CLEAR/BLACK ANODIZED J ULTIMATE LOAD N/A MILL FINISH i CERTIFICATION: UL 2703,FILE E359313 I BOXES OF 8 CER TION(LBS): MATE :(LBS):-T- rUL 2703,FILE E359313 I I -1 ; TORQUE SPECIFICATION: N/A LB-FT BUNDLES OF 120 TORQUE SPECIFICATION: 12 LB-FT CERTIFI WEIGHT(LBS): 8.46 WEIGHT(LBS): 10.71 II, RACKING&RAIL CUT SHEET to I- w w Grounding Specifications Grounding Specifications i MID CLAMP ASSEMBLY a U System Bonding Methods _ Ilsco Lay-in Lug Assembly o d e SnapNrack Mid Clamp \ I ✓_ ___ W co Cr ®SnapNrack Adjustable End Clamp SS BONDING PIN - ®SnapNrack UR-40 Rail Splice --- _ —MODULE ry ' FRAME Q o I� SnapNrack UR-60 Rail Splice 1 \ - - NN O N 0 1 / - RAIL , O e-I \-CHANNEL NUT �� W NO MR SS \ \1 C RNL 11.0 CdLA0Bt GROAN UG ' `. SS BON gNOCUP RAIL SnapNrack module ..- �� (3 TOTAU SPLICE clamps contain a r ASSEMBLY SnapNrack Channel Nut NO KAT s� \ N / \ - � With integral bonding Z / l 1 /� \�,, clips or pins in assembly LO 1 I \ / ( \ to properly bond the \ / 1 / system(except Universal COPRA WISE, Q a0 End Clamps). Ground Path Details t c A 2 0 SPLICE aTCM-1 -- - O Q I.-' 5- ASSEMBLY .tY -.NAY --A.,- 1- c E 0 NOIe. a T., N O SnapNrack Ultra Red Splices contain integral bonding clips TO EGC 3 to .-IZ In assembly to properly bond the system. , O 2 w O Z ® Z a SnapNrack Ground Lug Assembly a a o g a 55/M 6 ISRR II BOLT S.S.WAS ER 55. o El o 0 0 0 1.:41__I m 7 o 4 � � . m sNMtFAIX GROuro TO EGC d O LIG,6l1 AM m O 0 0 El o 0 00 p LL` 7-COPPER WIRE,TIP. it,oi N RAIL RAIL SPLICE MOUNT 0 GROUND LUG Q MODULE CLAMP I ` M=MEND A y J �:�^GROUND PATH EQUIPMENT GROUNDING CONDUCTOR X=X{ND CLAMP SNAFNRACK �` 4 U=UNIVERSAL END j ULTRA SERIES RAIL \,' CLAMP /J grAMAcK BO L 14 E NUT t/ 51 RACKING&RAIL CUT SHEET cn w w Grounding Specifications Grounding Specifications N � ' D 11:"" U Ground Path Details-SolarEdge INSTALLATION INSTRUCTIONS-SNAPNRACK GROUND LUG apa, Oa L_pB�pacO Ci 11.3 TOEGCT.—ss�\�— W Q oO ESE WI 20 :3 ® 80o ate" 0 W 1)Snap the SnapNrack Ground Lug 2)Place grounding conductor into 3)Tighten hardware to 16 ft-lbs. Into the rail channel on one rail per slot underneath split ring washer. TO EGC module row. 0 Install Note: 0 Install Note:`n' z SnapNrack Ground Lug may be used SnapNrack Ground Lug only Listed po�p In side or top channel,and may be for use wit,6-12 AWG solid copper O d rotated 90 degrees relative to slot to conductor facilitate running copper across top Q Q RAIL o RAIL SPLICE MOUNT 0 GROUND LUG QM MODULE CLAMP nl(ids. a, M•MDCWaP J C A sue-'GROUND PATH EOUIPMENTGROUNDING SOLAREDGE x•x{ND CLAMP [) O C coxoucTOn o1=nMI2ER A ULAMP50L END INSTALLATION INSTRUCTIONS-ILSCO LAY-IN LUC. > ¢ y R. f n � v 5 E > w Ground Path Details Enphase `\ 2 c u C an . : g <,, a 1 \ i/_ g a o` o -� —la � -� r= - 1)Drill and deburr a 1/4"hole In 2)Place grounding conductor Into 3)Tighten set screw per Ilsco's m v o the back side of the rail for the slot recommendation(see below). a N u x �uro p u7 Ilsco lug to attach to,place the bolt �} ry 2 _ CI ❑ � through the hole,and attach the lug Y "I' a c a assembly on one rail per module Torque set screw to 20 in-Ibs for#10- row. #14 solid and stranded copper,25 m In-lbs for#8 stranded copper,and 35 u. {} Install Note' in-lbs for#4-#6stranded copper. g fg ID B 2 CI 0 02 Torque rail connection to 35 In-lbs. } 0 Note m J •System has been evaluated to a maximum overcurrent device(OCD)protection level of 20 Amps. H RAIL ®RAIL SPLICE 0 MOUNT 0 GROUND LUG QM MODULE CLAMP •Universal End Clamp(UEC)does not bond module to rail.Be sure to separately ground any modules that are only secured by UECs. N J M•MIOCtAMP especially during servicing. GROUND PATH ,i,EQUIPMENT GROUNDING a ENPHASE X•X{ND CLAMP •SnapNrack recommends that bare copper never come Into contact with aluminum. Ie CONDUCTOR V U•UNIVERSAL nap ERSAL END •SnapNrack Ground Lug:torque bolt to 16 ft-Ibs.The Ground Lug may be used In side or top channel.It may be rotated 90 degrees relative INVERTER CLAMP • /7 to Slot to facilitate running copper across top of rails. •Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling of a hole in the rail. 1 53 •Ilsco hardware connection to rail:5 ft-lbs.Torque for lug sat screw.#10-#14 solid and stranded copper-20 in-Ibs,#8 stranded copper-25 hp. In-Ibs.#4-#6 stranded copper-35 In-lbs. RACKING&RAIL CUT SHEET N I— w u1 Grounding Specifications NI ._ -i- ce au in Ground Path Details-DynoBond �trugtft a. U W fir. 0- August 6,2019 Li 0'E 0 O 0 I] SnapNrack W j CC . © 775 Fiero Lane,Ste.200 e 11J San Luis Obispo,CA 93401 ea TEL(877)732-2860 W 0 ON a)Attn.:SnapNrack-Engineering Department- Q O �-y Subject:Report 4 2017-03227.11-Engineering Certification and Span Tables for the SnapNrack Ultra Rail Solar E❑ {0 E) 0^E —- 0 [) Photovoltaic Racking System PZSE, CC Inc.-Structural Engineers has reviewed and analyzed the SnapNrack Ultra Rail Racking System,a proprietary mounting system constructed from modular parts,which is intended for rooftop installation of solar photovoltaic(PV) Le Ei 0 0 0 El cr I] 0 QQQ���EEE panels;and has provided the attached span tables.This review included the complete system including the"UR-40" aluminum rail(6005-T56 alloy),attachment devices,splice elements,and PV Panels.All Information,data,and analysis TO EGC contained within are based on,and comply with,the following building codes and typical specifications: N Building Codes: 1. ASCE/SEI 7-16,Minimum Design Loads for Buildings and Other Structures,by American Society of Z Civil Engineers _,y 2. 2018 International Building Code,by International Code Council,Inc. 11 El 0 I7 0 0 m 0 Ei [D 3. 2018 International Residential Code,by International Code Council,Inc. U e4 ..-cto-- "me,- 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV) C Panels,November 1,2012 by ICC-ES J e w 2 5. Aluminum Design Manual 2015,by The Aluminum Association,Inc. O ` ` c 6. ANSI/AWC NDS-2015,National Design Specification for Wood Construction,by the American > y 2 RAIL RAIL SPLICE 0 MOUNT 0 GROUND LUG Q MODULE CLAMP Wood Council 0 .... - O. M=MIDCLAMP O -6C DVNORAXX DYNOBOND 1.EQUIPMENT GROUNDING CONDUCTOR E=END CLAMP Design Criteria: Risk Category 11;Seismic Design Category=A-E w �2p t = GROUND PATH a N V O wind Loads: Basic Wind Speed(ultimate)per ASCE 7-16=95 mph to 190 mph.Includes roof pitches from 0'to 90', in .r-I Z R/C(0IMS2),DynoRaxx(E357716)photovoltaic bondin up to 60 feet mean roof height,and exposure categories B,C,&D.Parapets,roof overhangs,and g jumper Cd[.n0.DynOBOnd topographic wind speed adjustment have not been considered. Y h is an optional component that may be used with this system.The DynoBond jumper 8 us W Z has been evaluated to provide module to module bonding.The DynoBond device Snow Loads: Ground Snow Load=0 to 120(psi).Spans are based on the sloped roof snow load(Ps)corresponding isI < C G Q attaches to the frame flange of adjacent modules. to each ground snow load.See Appendix Ato adjust span tables for non-reducible snow loads. vti Z p 00 PV Modules: All solar PV modules with metal frames."60-Cell"tables are applicable for modules up to 5'-6"(66") long;"72-Celt tables are applicable for modules up to 6'-6"1781 long;and"Landscape"tables are L g i applicable for modules up to 3'4-1/2"(40.1/2")long in the narrow direction.Module length is C - defined to be perpendicular to the rail,regardless of panel orientation. 't '' f rio If you have any questions,do not hesitate to call. r'+ ec ei es itPrepared by: m w P25E,Ito.-Structural Engineers a Roseville,CA LL 1478 Slone Polnl Drive Suite 190.Roseville CA 95661 916.9613960 916.961.7965 www.p0sa.com 1/953 ` 111 ei LLZ. J,J J To j 55 �A RACKING&RAIL CUT SHEET /) I- w w 2 N ® .n Lu Li- O d structural tNGINEERS w f -,m Cr August 6,2019 K h 1,2.1 r9 N SnapNrack cai N 775 Fiero Lane,Ste.200 San Luis Obispo,CA 93401 0 Q TEL:(877)732-2860 0O a--I I CC Attn.:SnapNrack-Engineering Deparbnent W CC Re:Report 4 2017-03227.11-SnapNrack Ultra Rail Solar Photovoltaic Racking System with UR-40 Rail _ Subject:Engineering Certification for the State of Massachusetts PZ5E,Inc.-Structural Engineers has provided engineering and span tables for the SnapNrack Ultra Rail Racking System with UR- 40 Rail,as presented In POSE Report a 2017-03227.11,"Engineering Certification and Span Tables for the SnapNrack Ultra Rall Solar Photovoltaic Racking System...All information,data,and analysis therein are based on,and comply with,the following N budding codes and typical specifications: Z 5 o Building Codes: 1. ASCE/SE17-10,Minimum Design Loads for Buildings and Other Structures,by American 1 lit, O Sodety of CNil Engineers U .4 0 2. 2015 International Building Code,by International Code Council,Inc. Q Q 3. 2015 International Residential Code,by International Code Coundl,Inc. J . u 2 4. AC928,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic)PV) Q Q A c) Panels,November 1,2012 by ICC-ES 7 Q F`W- y 5. Aluminum Design Manual 2015,by The Aluminum Association,Inc. 0 C E 6. ANSV W CL >AWCNDS-2015,National Design Specification for Wood Construction,by the American 0 ce I u Wood CouncilL 1 N N O Design Criteria: Risk Category II en .--1 Z Seismic Design Category=A-E Y Basic Wind Speed(ultimate)per ASCE 7-10:up to190 mph Q in N Z Ground Snow Load a-0 to 120 IranMr K CC p '-I Z O O Q This letter certifies that the loading criteria and design basis for the DIGITALLY SIGNED SnapNrack Ultra Rail Racking System with UR-40 Rail Span Tables are tH OF p 8 a. in compliance with M co F e above des. ; p0 v I AUL R O a cRER a m UCTURAL N "-I ? 2 tit If you have any questions on the above,do not hesitate to call. , .50100 mi- K V.mi Y• i v e mr Er Prepared by: u PZSE,Inc.-Structural Engineers Roseville,CA `} iii 8150 Sierra College Boulevard.Suite 150.Rosevgle.CA 95661 p J 1/1 916-961.7960 916.961.1965 www.pue.carD W J To 1Pr STANCHION-ROOF ATTACHMENT CUT SHEET LVI Y DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: W SnapN - S�p�lrradc SNAPNRACK ULTRA RAIL COMP KIT mwatkins SNAPNRACK ULTRA RAIL COMP KIT mwatkins 1- _ REVISION: __ ___ _ _ __ REVISION: a D PART NUMBER(S): PART NUMBER(S): n V B PkIMENIA g d SEE BELOW �w. � "T OM MA SEE BELOW � He w . 5 -,m a UMBRELLA L FOOT PROPERTIES a'^ LU SKU DESCRIPTION N 242-01219 ULTRA RAIL UMBRELLA L FOOT,SILVER <e 00 4/ 242-01220 ULTRA RAIL UMBRELLA L FOOT,BLACK 0 r-I �O 1.4 `, :i..-7 G r-I 1.37 \ �1.00 tY i� .. �- i .38 �—� .30 . Thir) 1.00 jam' SLOT . t 0 . �O 1.50 i O�Q J 1 N 2.78 Z '� 1.78 1.62 g 0 CO a U 0 Q G 1.ao� I- 1.so� z < 0 17. COMP FLASHING PROPERTIES ,O a d y ` ti, © SKU DESCRIPTION I- 'c C %ill, 232-01375_ COMP FLASHING,9"X 12",BLACK ALUM 0 w 2 L 232-01376 COMP FLASHING,9"X 12",SILVER ALUM d -a-, N o N rl Z , � T z< W .5 Z ! ,..,•-i Zgaa . 01.00 SnapH p - G`N 6.75 _.m.rruosdrsSahara_ a g 4 o e I >f; N Y N c a 11.75 _ _ m u PARTS UST t G — LL ITEM QTY PART NUMBER DESCRIPTION 4.20 j 1 1 242-92266 SNAPNRACK,UMBRELLA LAG,TYPE 3,4IN,SS I �- 2 1 242-01219,242-01220 SNAPNRACK,ULTRA FOOT FOR U FLASHING,SILVER/BLACK c y W 3 1 232-01375,232-01376 SNAPNRACK,COMP FLASHING,9IN X 12IN,SILVER/BLACK AWM MATERIALS: 6000 SERIES ALUMINUM,STAINLESS STEEL,RUBBER 95.35 I N DESIGN LOAD(LBS): 405 UP,788 DOWN,236 SIDE 3.25 (\ J To �' ......1 ULTIMATE LOAD(LBS): 2006 UP,4000 DOWN,1070 SIDE \ I - I / > , TORQUE SPECIFICATION: 12 LB-FT 1 CERTIFICATION: UL 2703,FILE E359313 I . 8.75 .45—.. �- II WEIGHT(LBS): 0.80 ALL DIMENSIONS IN INCHES I/ AC DISCONNECT CUT SHEET FN- Switching Devices w Er T•N 1.1 Safety Switches „) 1 Powering Business Worldwideti.• Standards sad cerlificatio.s ° U General Duty Non-Fusible alganaraldugswitches • ULlistedFdeNo E5239 cc o p f0 bate 100A end all heavy- duty • enclosedSafetyI. Switch switches incorporate switches and NEMA Std. w these IC-Series switch KS-1 DG222URB design features. r `" "' 0. Two Doints of contact _-■ O provide a positive UPC:782113144238 " t` opn coon• close,easier y w a '6-" q pe non.and also he p q prevent contact burning _r'ti'A'„a'�ei•A• SMMIC�%RCadte. p r Dimensions: for l°"°"`°°ntactII IV o t-I •The position ION or OFF) • General-duty swrtchea can be clearly seen from •Door cannot be opened exceed the requirements r •Height:7.5 IN ' when the handle e in the > a distance and the lengthof Uniform Building provies d for easy operation ON position.Front and Code 1UBCI and CalifoCaliforniaw o •Length:6.41 IN ;;;44� side operable defeater Code Title 2a OSP-0011-10, CE mechanism provides OSP-0012.10 •Width:8.41N �i ; access when ■ ".' 4 necessary ce single- t, switches Wei ht:9 LBO `` . fipe.eaton,com Notes:WARNING!Switch is not approved for MAY• "" Z service entrance unless a neutral kit is installed. Protects against accidental �I e contact with energized fiWv .etleq.wry /. ,'.,; l- d to Warranties: parts.Probe holes enable n _v the user to test d the line • Personnel safety feature O side is energized without because the Large hasp can Q Q • Eaton Selling Policy 25-000,one(1)year from accommodate m e removing the shield. co e u the date of installation of the Product or Not provided on general- three 3/8-inch TeipaWOWN. 0 2 2 c duty switches,but shank locks > rq r o eighteen(18)months from the date of shipment avelaaeaea field kit •Mampla"umbe are G F0. or factory installed Provided on the top, 0 — . E of the Product,whichever occurs first. NENIATypes s'1 and both O w .5 t 1 and 3R Specifications: enclosures mrough 200A d V •Type:General Duty/Non-Fusible 3 N ~ Z •Amperage Rating:60Atn an 0 au a •Enclosure:NEMA 3R Vir "'e°""0aeeA"t�"*� , z o o •Enclosure Material:Paintedgalvanized steel ,,,,,,•,w, • wdlockenet at°etopaan be tnet _ a a bottom Fred at the top and •Fuse Configuration:Non-fusible m"°m as applicable INFO.MINib 6. g '< •Number Of Poles:Two-pole v w For switdres�n a NEMA y a 0 Type 3R,30-200A.Use ,mi - Q 00 •Number Of Wires:Two-wire a Myers type hub for i 2 i° all others e; •Product Category:General Duty Safety Switch < •Voltage Rating:240V m o Supporting documents: •Eatons Volume 2-Commercial Distribution >- •Eaton Specification Sheet-DG222URB to. W Certifications: "J J • UL Listed " p/ I e Product compliance:No Data V2.Tt-25 Volume 2—Commercial Distribution CA08100003E-May 2010 siorreton.wn ©2016 Eaton.All rights reserved. BACKUP INTERFACE CUT SHEET N 1I— w w SolarEdge Energy Bank N 10kWh Battery Q SolarEdge Energy Bank I For North America auoCl- O BAT-10N1Pv. an F 5 10 kWh Battery BATTERY SPECIFICATION 9A3 cn W Cf w For North America } r.I. w 0 Pet ROWmp niav<y SOW - -- W o vaAag R g 3V4a Cl rr a1 -- 10 rtcn E.,Ax, Wades, o .-1 �" r 'FARCla ur rc,3w - CC WARRANTY STANDARD COMPLIANCE _ > ruu Cat IS WSSB _ --- _MECHANICAL SPECIFICATIONS _ tul 5013 Neural 31.1a466.967/121 IIt962S0 m/inn n 26)/III b/ks Piq te raa,.n:y* A r,a.ImanN r laabr3-ernpcatre, .dto.l<2/-aGk<6e Saw,Saw, ryaAae(mne p,n 9 e,ve,6 .[rib<86/-IOW<30 t) Cctaage Temµ./re Qe+a pun 3 mste 22:a• 0!-3 n.fi I- Z *Wale 6ie2/A[G ft o,tnae Pueatan WS,/NEW 3R-i.Y.ravjamov(teevrtlda r O L.)Co"Cidingnanual/v,n/tm _ _ O Nd eta im6uarce) <2/ Lv Q ._ •ire SirE00 Eh,Bank aa,.gee I.ufe..afarefmoner t.*ma m.v.ercn ire.nna.ma..m*.nencosaMrayrnnn rwasn(one xoew., J c u 2 rrtk0 a m 2 t t.,a.a<n in n<ymae. -,eegr0.rs.aerye0.am,aaee.ww..n agk+anm..o,ac.eu n.`vn. O O C 0-0ns h+wa.$el,bpn,.765«97,-t0a770-nl > 'n G1 0 3,,,,,,,re/en.6 Om*feru en S.YEage Energy ur., 0 I— a it A...ip„uNia Nam.,,fneq a •f fn.,. dbafic,ae,a]an 0.":•eJ a.-;pa tv¢ery.dlgae l� -o C B a ,<e �' 2 m LM ,vaas .. he. A. neq. lMme u the 0 Q a c -IMO a Please see mA 9e. .en O, .esvwdeaM�•s mre^er v/e.[vvi e..ner.an E. N an .-t Z SalarEd9e Energy Bank Battery-Accessories(purchased separately) 00 W Z Accessory PN t-i Q G p Q Optimized for SolarEdge Energy Hub Inverters(') - lAC-a6A)-kRtTG-01 z,g o r,r,rx.,m,r-- na, oa a '..,L-„ xgy BaA Bapeie,.+M asrxJe 9aemn P.C.8:-1.,,,, / Maximized system performance,gaining / Solar,storage,EV charging,and smart devices NC-PER-,r. - _ p` " i more energy to store and use for on-grid and all monitored and managed by a single app to - a �u g backup power applications optimize solar production,consumption and < �^ + n rr, s>„n<al urn; vs 6 1 v-.• -- N Q OS . backup'power i < / Integrates with the complete SolarEdge n a y.ma residential offering,providing a single point /Wireless communication to the inverter, L.' O of contact for warranty,support,training,and reducing wiring,labor and installation faults en t12 simplified logistics&operations a / Simple plug and play installation,with automatic / DC coupled battery featuring superior overall SetApp-based configuration system efficiency,from PV to battery to grid /Includes multiple safety features for battery I Scalable solution for increased power and protection L. W capacity with multiple SolarEdge inverters m 1 and batteries vCIi J d 11 edge.com ,n.... solar.-I a r.- l e - W*,.s :. rn,,a,�..�...�....P . :.>a.ag,..�.,a CE RoH$ solaredge.com _ 1. .a 1 ,, r City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: 12 Calvin Terrace Northampton MA 01060 The debris will be transported by: Valley Solar LLC The debris will be received by: Valley Recyling, Northampton Building permit number: Name of Permit Applicant Valley Solar LLC 2/23/2022 ��aii:c Date Signature of Permit Applicant The Commonwealth of Massachusetts Department of Industrial Accidents _;z ►_ Office of Investigations =e.1_ Lafayette City Center "•- 2 Avenue de Lafayette,Boston,MA 02111-1750 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Valley Solar LLC Address: 340 Riverside Dr City/State/Zip:_ Florence, MA 01062 Phone#:413-584-8844 Are you an employer?Check the appropriate box: Type of project(required): l.® I am a employer with 27 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition workingfor me in anycapacity. employees and have workers' P h' 9. ❑Building addition [No workers' comp.insurance comp.insurance.: required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no employees. [No workers' 13.0Other Solar comp.insurance required.] 'Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Applied Underwriters Policy#or Self-ins.Lic.#: 376140840101 Expiration Date: 9/1/2022 Job Site Address: 12 Calvin Terrace city/state/zip: Northampton MA 01060 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under,{he pains an('penalties of perjury that the information provided above is true and correct. Signature: R O- - Date: 1/14/2022 Phone#: 413-584-8844 Official use only. Do not write in this area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(check one): 11:Board of Health 21:Building Department laity/Town Clerk 4.0 Electrical Inspector 5EFlumbing Inspector 6.EJOther Contact Person: Phone#: