Loading...
Permit Set (Revised) (19) (1)1.1.1PROJECT NOTES:1.1.2THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICCODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATIONINSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITYHAVING JURISDICTION’S (AHJ) APPLICABLE CODES.1.1.3THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEMINSPECTED PRIOR TO PARALLEL OPERATION1.1.4GROUND FAULT DETECTION ANDINTERRUPTION (GFDI) DEVICE IS INTEGRATED WITHTHE MICROINVERTER IN ACCORDANCE WITH NEC 690.41(B)1.1.5ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, ANDSOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE INPHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY1.1.6MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMPCOEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATEDACCORDING TO NEC 690.7.1.1.7ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCECIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILLBE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLEDACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3].1.1.8ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IFEXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGEWILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.1.2.1 SCOPE OF WORK:1.2.2PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OFTHE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BERESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN,SPECIFY, AND INSTALLTHE EXTERIOR ROOF-MOUNTED PORTION OF THEPHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT.1.3.1 WORK INCLUDES:1.3.2PV ROOF ATTACHMENTS - IRONRIDGE FLASHFOOT21.3.3PV RACKING SYSTEM INSTALLATION - IRONRIDGE XR-100 1.3.4PV MODULE AND INVERTER INSTALLATION - HANWHA Q CELLS Q.PEAK DUO BLKML-G10+ 400 / ENPHASE IQ7PLUS-72-2-US 1.3.5PV EQUIPMENT GROUNDING1.3.6PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX1.3.7PV LOAD CENTERS (IF INCLUDED)1.3.8PV METERING/MONITORING (IF INCLUDED)1.3.9PV DISCONNECTS1.3.10PV GROUNDING ELECTRODE & BONDING TO (E) GEC1.3.11PV FINAL COMMISSIONING1.3.12(E) ELECTRICAL EQUIPMENT RETROFIT FOR PV1.3.13SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODEGENERAL NOTESN2017MSCOPE OF WORKSYSTEM SIZE:STC: 17 x 400W = 6.800kWPTC: 17 x 376.55W = 6.401kW DC(17) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 400(17) ENPHASE IQ7PLUS-72-2-USATTACHMENT TYPE: IRONRIDGE FLASHFOOT2MSP UPGRADE: NOOWNERNAME:BARBARA BRICKERPROJECT MANAGERNAME:PHONE: CONTRACTORNAME:C & L POWER SOLUTIONS LLCPHONE: AUTHORITIES HAVING JURISDICTIONBUILDING: NORTHAMPTON COUNTYZONING: NORTHAMPTON COUNTYUTILITY: NATIONAL GRID - MASSACHUSETTS -RESIDENTIALDESIGN SPECIFICATIONSOCCUPANCY: IICONSTRUCTION: SINGLE-FAMILYZONING:RESIDENTIALGROUND SNOW LOAD: 40 PSFWIND EXPOSURE: BWIND SPEED: 117 MPHAPPLICABLE CODES & STANDARDSBUILDING: MASSACHUSETTS BUILDING CODE, 9THEDITION, AS AMENDED (780 CMR)MASSACHUSETTS RESIDENTIONALBUILDING CODE, 9TH EDITION, ASAMENDED (780 CMR)ELECTRICAL: NEC 2020FIRE:MASSACHUSETTS COMPREHENSIVEFIRE SAFETY CODE (527 CMR 1.00)PROJECT INFORMATIONNEW PV SYSTEM: 6.800 kWpBRICKER RESIDENCE64 MEADOW STNORTHAMPTON, MA 01062ASSESSOR'S #: M:022B B:0016 L:0001BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1T-001.00COVER PAGE(SHEET 1)01AERIAL PHOTONOT TO SCALENEWS02PLAT MAPNOT TO SCALESHEET LIST TABLESHEET NUMBERSHEET TITLET-001COVER PAGEG-001NOTESA-101SITE PLANA-102ELECTRICAL PLANA-103SOLAR ATTACHMENT PLANS-501ASSEMBLY DETAILSE-601LINE DIAGRAME-602DESIGN TABLESE-603PLACARDSR-001RESOURCE DOCUMENTR-002RESOURCE DOCUMENTR-003RESOURCE DOCUMENTR-004RESOURCE DOCUMENTR-005RESOURCE DOCUMENTR-006RESOURCE DOCUMENTMEADOW ST 2.1.1SITE NOTES:2.1.2A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHAREGULATIONS.2.1.3THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEMISA UTILITY INTERACTIVE SYSTEM WITH STORAGE BATTERIES.2.1.4THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANYPLUMBING,MECHANICAL, OR BUILDING ROOF VENTS.2.1.5PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING ANDPROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTIONNEC 110.26.2.1.6ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED INACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'SINSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THEBUILDING OR STRUCTURE.2.2.1EQUIPMENT LOCATIONS:2.2.2ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BYNEC 110.26.2.2.3WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOREXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C)AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.4JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULESACCORDING TO NEC 690.34.2.2.5ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTERIS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNELACCORDING TO NEC APPLICABLE CODES.2.2.7ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOROUTDOOR USAGE WHEN APPROPRIATE.2.3.1STRUCTURAL NOTES:2.3.2RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TOCODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE ADESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND AMINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS.2.3.3JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS.IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCALREQUIREMENTS.2.3.4ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED ANDSEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSEDCONTRACTOR.2.3.5ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THESPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER.2.3.6WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BESTAGGERED AMONGST THE ROOF FRAMING MEMBERS.2.4.1WIRING & CONDUIT NOTES:2.4.2ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODEREQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING.2.4.3CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7.2.4.4VOLTAGE DROP LIMITED TO 1.5%.2.4.5DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRINGSYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLEWIRING CLIPS.2.4.6AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GRAYIN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGETO BE MARKED ORANGE [NEC 110.15].4.5.1GROUNDING NOTES:2.5.2GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL BE RATED FORSUCH USE.2.5.3PVEQUIPMENTSHALLBEGROUNDEDACCORDINGTONEC690.43ANDMINIMUM NEC TABLE 250.122.2.5.4METAL PARTS OF MODULE FRAMES,MODULE RACKING, AND ENCLOSURESCONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A).2.5.5EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC690.45 AND MICROINVERTER MANUFACTURERS' INSTRUCTIONS.2.5.6EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS ASSHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IFWEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED ATTHE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS.2.5.7THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCHTHAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDINGCONDUCTOR TO ANOTHER MODULE.2.5.8GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOREDGREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119]2.5.9THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, ORINADEQUATE, AGROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TONEC 250, NEC 690.47 AND AHJ.2.5.10GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TOREDUCE FIRE HAZARDS2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES:2.6.2DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCHIS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TOTHE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.3DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BELOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.4PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE ARAPID SHUTDOWN FUNCTION TO REDUCESHOCK HAZARD FOR EMERGENCYRESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D).2.6.5ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9,AND 240.2.6.6MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER ORGROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B).2.6.7IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTIONACCORDING TO NEC 690.11 AND UL1699B.2.7.1INTERCONNECTION NOTES:2.7.2LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC705.12 (B)]2.7.3THE SUM OFTHE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAYNOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)].2.7.4THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUITCURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITEEND OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(2)(3)].2.7.5AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTALRATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BEEXCLUDED ACCORDING TO NEC 705.12 (B)(2)(3)(C).2.7.6FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12(B)(2)(1)2.7.7SUPPLY SIDE TAP INTERCONNECTION ACCORDING TONEC 705.12 (A) WITHSERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.422.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPTFROM ADDITIONAL FASTENING [NEC 705.12 (B)(5)].N2017M N2017M BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1G-001.00NOTES(SHEET 2) GENERAL NOTES1.FIELD VERIFY ALL MEASUREMENTS2.ITEMS BELOW MAY NOT BE ON THIS PAGEPROPERTY LINENEWS01/24'=1'-0''SITE PLAN0112'24'BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1A-101.00(SHEET 3)AREA OF WORKENTRANCESITE PLANUTILITY METERAC DISCONNECTMA SMART UTILITY METERAC COMBINER BOXMEADOW ST19'-0"73'-5"8'-11"32'-9" MODULE:HANWHA Q CELLSQ.PEAK DUO BLK ML-G10+ 400400 WATTS41.1"74"GENERAL NOTES1.FIELD VERIFY ALL MEASUREMENTS2.ITEMS BELOW MAY NOT BE ON THIS PAGEMODULE STRINGINGMODULE STRINGINGBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1NEWSA-102.00(SHEET 4)A(N) (1) JUNCTION BOX01/8" = 1'-0"ELECTRICAL PLAN014'8'ELECTRICAL PLANEXTERIOR PV EQUIPMENT(N) (1) AC DISCONNECT(N) (1) MA SMART UTILITY METERINTERIOR PV EQUIPMENTBARRAY 1 - 3.600 kW[x9] (N) MODULESTILT: 9 DEGREESROOF PITCH: 2:12AZIMUTH: 159 DEGREES(E) (1) UTILITY METER(E) (1) MAIN ELECTRICAL PANELA(N) (1) AC COMBINER BOXARRAY 2 - 3.200 kW[x8] (N) MODULESTILT: 18 DEGREESROOF PITCH: 4:12AZIMUTH: 160 DEGREESAAAAAAAABBBBBBBB GENERAL NOTES1.FIELD VERIFY ALL MEASUREMENTS2.ITEMS BELOW MAY NOT BE ON THIS PAGEROOF TRUSSESMODULE:HANWHA Q CELLSQ.PEAK DUO BLK ML-G10+ 400400 WATTS41.1"74"BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1NEWS01/8" = 1'-0''SOLAR ATTACHMENT PLAN014'8'A-103.00(SHEET 5)SOLAR ATTACHMENT PLANROOF MATERIAL IS ASPHALT SHINGLEFLUSH MOUNT SOLARMODULES ATTACHED TOROOF SURFACE (SEE SHEETS-501 FOR MOUNTINGDETAILS)ROOF MATERIAL ISASPHALT SHINGLEFLUSH MOUNT SOLARMODULES ATTACHED TOROOF SURFACE (SEE SHEETS-501 FOR MOUNTINGDETAILS)30'-11"24'-9"By Yuri at 6:44:24 PM, 12/28/2021 SHEET KEYNOTES1. ROOF MATERIAL: ASPHALT SHINGLE2. ROOF STRUCTURE: TRUSS3. ATTACHMENT TYPE: IRONRIDGE FLASHFOOT 24. MODULE MANUFACTURER: HANWHA Q CELLS5. MODULE MODEL: Q.PEAK DUO BLK ML-G10+ 4006. MODULE LENGTH: 74 IN.7. MODULE WIDTH: 41.1 IN.8. MODULE WEIGHT: 48.5 LBS.9. SEE SHEET A-103 FOR DIMENSION(S)10. MIN. FIRE OFFSET: NO FIRE CODE ENFORCED11. TRUSS SPACING: 24 IN.12. TRUSS SIZE: 2"X4" NOMINAL13. LAG BOLT DIAMETER: 3/8" IN.14. LAG BOLT EMBEDMENT: 2-1/2" IN.15. TOTAL # OF ATTACHMENTS: 6516. TOTAL AREA: 359.05 SQ. FT.17. TOTAL WEIGHT: 1007.53 LBS.18. WEIGHT PER ATTACHMENT: 15.5 LBS.19. DISTRIBUTED LOAD: 2.81 PSF.20. MAX. HORIZONTAL STANDOFF: 48 IN.21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITHMODULE MANUFACTURER'S INSTRUCTIONS.22. STANDOFF STAGGERING: YES23. RAIL MANUFACTURER (OR EQUIV.): IRONRIDGE24. RAIL MODEL (OR EQUIVALENT): XR-10025. RAIL WEIGHT: 0.68 PLF.26. MAX. TRUSS SPAN: N/A FT.27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.S-501D52011121413151822ROOF SLOPE 910106217S-501D4315425242382721. FIELD VERIFY ALL MEASUREMENTSGENERAL NOTESBFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1S-501.00(SHEET 6)ASSEMBLY DETAILSD4DETAIL (TRANSVERSE)NOT TO SCALED5DETAIL (LONGITUDINAL)NOT TO SCALED1RACKING DETAIL (TRANSVERSE)NOT TO SCALED3RACKING DETAIL (TOP)NOT TO SCALED2RACKING DETAIL (LONGITUDINAL)NOT TO SCALENOTE :1)ARRAY 1 : 2 x 4 RAFTERS @ 24" O.C. (VIF), MAXIMUM HORIZONTAL SPAN OF THE RAFTERS BETWEEN BEARING SUPPORTS SHALL NOT EXCEED 6.4 FT.By Yuri at 6:44:26 PM, 12/28/2021 34AC DISCONNECT, 60AFUSE, 30AEQUIPMENT LEFTOF LINE IS (N) NEWEQUIPMENT RIGHT OFLINE IS (E) EXISTINGUNLESS OTHERWISENOTED.(E) GROUNDINGELECTRODEGROUNDRODTAPNNL2L1NGTO (E)LOADSPV SYSTEM EQUIPPED WITH RAPIDSHUTDOWS DISCONNECT PER NEC 690.12SYSTEM COMPLIANT WITH NEC 690.13IN BRANCHBLACKIN BRANCHBLACKREDRED1BA98(17) HANWHA Q CELLSQ.PEAK DUO BLK ML-G10+ 400(17) ENPHASEIQ7PLUS-72-2-USJUNCTIONBOXG(E) MAIN ELECTRICAL PANEL240/120 V 1Ø, 3WMAIN BUSS:A200GL1NL2ENPHASE ENVOYCOMMUNICATIONSGATEWAYAC COMBINER BOX 125A120/240V, 1Ø, 3WMAX. CONTINUOUS CURRENT: 65AMAX. OCPD: 90ACB1-220A20A15ACB3ABMODULE STRINGINGMODULE STRINGING(E)MAIN200AGF1-2SW130A(E)UTILITYMETERTO UTILITYGRID (OH)L2NL1V TOP LUGSBOTTOM LUGSMA SMART UTILITY METERLOADLINE2CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONSIDTYPICALCONDUCTORCONDUITCURRENT-CARRYINGCONDUCTORS IN CONDUITOCPDEGCTEMP. CORR.FACTORCONDUIT FILLFACTORCONT.CURRENTMAX. CURRENT(125%)BASE AMP.DERATEDAMP.TERM. TEMP. RATINGAMP. @ TERMINAL1110 AWG THWN-2, COPPER0.75'' DIA EMT420A10 AWG THWN-2, COPPER0.96 (32.7 °C)0.810.89A13.61A40A30.72A75°C35A2110 AWG THWN-2, COPPER0.75'' DIA EMT2N/A10 AWG THWN-2, COPPER0.96 (32.7 °C)120.57A25.71A40A38.4A75°C35A3110 AWG THWN-2, COPPER0.75'' DIA EMT230A10 AWG THWN-2, COPPER0.96 (32.7 °C)120.57A25.71A40A38.4A75°C35A416 AWG THWN-2, COPPER0.75'' DIA EMT2N/A6 AWG THWN-2, COPPER0.96 (32.7 °C)120.57A25.71A75A72A75°C65AE-601.00(SHEET 7)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1LINE DIAGRAM BILL OF MATERIALSCATEGORYMAKEMODEL NUMBERREFQTYUNITQTY/UNITDESCRIPTIONMODULEHANWHA Q-CELLSQ.PEAK DUO BLK ML-G10+ 400PM1-1717PIECES1HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400 400W 0INVERTERENPHASEIQ7PLUS-72-2-USI1-1717PIECES1ENPHASE IQ7PLUS-72-2-US 290W INVERTERDISCONNECTSQUARE DD222NRBSW11PIECE1SQUARE D D222NRB, FUSED, 2-POLE, 60A, 240VAC OR EQUIVALENTPRODUCTION METERGENERIC MANUFACTURERGEN-METER-80AM11PIECE1ELECTRICAL METER, OWNER APPROVEDMISC ELECTRICAL EQUIPMENTGEN-CABLE-CLIPHDWR20-10585PIECES1GENERIC CABLE CLIPAC COMBINER PANELENPHASE-IQ3-PANELEP11PIECE1ENPHASE IQ COMBINER 3 (X-IQ-AM1-240-3)MONITORINGENPHASE-ENVOYENV11PIECE1ENPHASE ENVOYWIRINGENPHASEQ-12-20-200EN1-1717PIECES1ENPHASE ENGAGE (TM) TRUNK CABLEWIRINGENPHASEQ-TERM-10EN181BUNDLE10ENPHASE ENGAGE (TM) BRANCH TERMINATORWIRINGENPHASEQ-SEAL-10EN191BUNDLE10ENPHASE ENGAGE (TM) WATERTIGHT SEALING CAPWIRINGGEN-10-AWG-THWN-2-CU-RDWR1-3200FEET110 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-10-AWG-THWN-2-CU-BLKWR1-3200FEET110 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-10-AWG-THWN-2-CU-WHWR2-320FEET110 AWG THWN-2, COPPER, WHITE (NEUTRAL)WIRINGGEN-10-AWG-THWN-2-CU-GRWR1-3110FEET110 AWG THWN-2, COPPER, GREEN (GROUND)WIRINGGEN-6-AWG-THWN-2-CU-RDWR410FEET16 AWG THWN-2, COPPER, RED (LINE 1)WIRINGGEN-6-AWG-THWN-2-CU-BLKWR410FEET16 AWG THWN-2, COPPER, BLACK (LINE 2)WIRINGGEN-6-AWG-THWN-2-CU-WHWR410FEET16 AWG THWN-2, COPPER, WHITE (NEUTRAL)WIRINGGEN-6-AWG-THWN-2-CU-GRWR410FEET16 AWG THWN-2, COPPER, GREEN (GROUND)WIREWAYENPHASEET-SPLK-05EN51BUNDLE5ENPHASE ENGAGE (TM) ENGAGE COUPLERWIREWAYGEN-EMT-0.75'' DIAWW1-4120FEET1EMT CONDUIT, 0.75'' DIAOCPDGENERIC MANUFACTURERGEN-CB-20A-240VACCB1-22PIECES1CIRCUIT BREAKER, 20A, 240VACOCPDGENERIC MANUFACTURERGEN-CB-15A-240VACCB31PIECE1CIRCUIT BREAKER, 15A, 240VACOCPDGENERIC MANUFACTURERGEN-FU-30A-240VACF1-22PIECES1FUSE, 30A, 240VACTRANSITION BOXGENERIC MANUFACTURERGEN-AWB-TB-4-4XJB11PIECE1TRANSITION/PASS-THROUGH BOX, WITH 4 TERMINAL BLOCKSSYSTEM SUMMARYBRANCH #1BRANCH #2INVERTERS PER BRANCH98MAX AC CURRENT10.89A9.68AMAX AC OUTPUT POWER2,655W2,360WARRAY STC POWER6,800WARRAY PTC POWER6,401WMAX AC CURRENT20.57AMAX AC POWER5,015WDERATED (CEC) AC POWER5,015WDISCONNECTSINVERTERSOCPDSMODULESASHRAE EXTREME LOW-25.9°C (-14.6°F), SOURCE: BARNES MUNI (42.16°; -72.72°)ASHRAE 2% HIGH32.7°C (90.9°F), SOURCE: BARNES MUNI (42.16°; -72.72°)REF.QTY.RATED CURRENTMAX VOLTAGECB1-2220A240VACCB3115A240VACF1-2230A240VACREF.QTY.MAKE AND MODELRATED CURRENTMAX RATED VOLTAGESW11SQUARE D D222NRB OR EQUIV.60A240VACREF.QTY.MAKE AND MODELPMAXPTCISCIMPVOCVMPTEMP. COEFF. OF VOCFUSE RATINGPM1-1717HANWHA Q-CELLS Q.PEAK DUO BLK ML-G10+ 400400W376.55W11.14A10.77A45.3V37.13V-0.122V/°C (-0.27%/°C)20AREF.QTY.MAKE AND MODELACVOLTAGEGROUNDOCPDRATINGRATEDPOWERMAX OUTPUTCURRENTMAX INPUTCURRENTMAX INPUTVOLTAGECEC WEIGHTEDEFFICIENCYI1-1717ENPHASE IQ7PLUS-72-2-US240VFLOATING20A290W1.21A15A60V97.0%E-602.00(SHEET 8)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1DESIGN TABLES MAIN DISTRIBUTIONUTILITY DISCONNECTFRONTBACK!CAUTION!POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM ROOF MOUNTED SOLAR ARRAYS WITHSAFETY DISCONNECTS AS SHOWN:E-603.00(SHEET 9)BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1N E W S PLACARDSPV ARRAYLABELING NOTES1.1 LABELING REQUIREMENTS BASED ON THE 2020 NATIONAL ELECTRICAL CODE,INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z5351.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVINGJURISDICTION.1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENTINVOLVED.1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED.1.5 ALERTING WORDS TO BE COLOR CODED. “DANGER” WILL HAVE REDBACKGROUND; “WARNING” WILL HAVE ORANGE BACKGROUND; “CAUTION” WILL HAVEYELLOW BACKGROUND. [ANSI Z535]ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL 1AT EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT (2" X 4").[NEC 690.13].POWER SOURCEOUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNINGLABEL 2AT POINT OF INTERCONNECTIONOVERCURRENT DEVICE (2" X 4").[NEC 705.12(B)(2)(3)(B)].LABEL 3AT POINT OF INTERCONNECTION, MARKEDAT DISCONNECTING MEANS (4" X 3").[NEC 690.54]LABEL 4AT EACH AC DISCONNECTING MEANS(4" X 1").[NEC 690.13(B)].INTERACTIVE PHOTOVOLTAIC SYSTEM CONNECTEDPHOTOVOLTAIC SYSTEM DISCONNECT LOCATEDWEST SIDE OF THE HOUSEDIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICEDISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTINGMEANS IF NOT IN THE SAME LOCATION (5 3/4" X 1 1/8").[NEC 690.56(B)]WHERE THE PV SYSTEMS ARE REMOTELY LOCATED FROM EACH OTHER, ADIRECTORY IN ACCORDANCE WITH 705.10 SHALL BE PROVIDED AT EACH PVSYSTEM DISCONNECTING MEANS.PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BE INSTALLED INBATHROOMS[NEC 690.4(D),(E)]PHOTOVOLTAIC POWER SOURCELABEL 9AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRINGMETHODS; SPACED AT MAXIMUM 10 FT SECTION OR WHERESEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS,OR FLOORS (5 3/4" X 1 1/8").[NEC 690.31(G)]LETTERS AT LEAST 3/8 INCH; WHITE ON RED BACKGROUND;REFLECTIVE[IFC 605.11.1.1]SOLAR PV SYSTEMEQUIPPED WITHRAPID SHUTDOWNTURN RAPID SHUTDOWN SWITCH TOTHE "OFF" POSITION TO SHUT DOWNPV SYSTEM AND REDUCE SHOCKHAZARD IN ARRAYSOLAR ELECTRICPV PANELSLABEL 6AT RAPID SHUTDOWN SYSTEM(3 3/4" X 5 1/4"). [NEC 690.56(C)(1)(A)].WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLARELECTRIC SYSTEMLABEL 7AT POINT OF INTERCONNECTION(2 3/4" X 1 5/8").[NEC 705.12(B)(3)]WARNINGSOLAR ELECTRICCIRCUIT BREAKERIS BACKFEDLABEL 8AT POINT OF INTERCONNECTION(2" X 1").[NEC 705.12(B)(3)]CAUTIONMULTIPLE SOURCES OF POWERLABEL 10AT UTILITY METER (5 3/4" X 1 1/8")[NEC 690.56(B)]RAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL 5AT RAPID SHUTDOWN DISCONNECT SWITCH (5 1/4" X 2").[NEC 690.56(C)(3)].AC DISCONNECTPHOTOVOLTAIC SYSTEMPOWER SOURCERATED ACOUTPUT CURRENTNOMINAL OPERATINGAC VOLTAGEAMPSVOLTSPHOTOVOLTAIC SYSTEMDISCONNECT20.57240 BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1R-001.00(SHEET 10)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1R-002.00(SHEET 11)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1R-003.00(SHEET 12)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1R-004.00(SHEET 13)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1R-005.00(SHEET 14)RESOURCE DOCUMENT BFADE23UNAUTHORIZED USE OF THISDRAWING SET WITHOUT WRITTENPERMISSION FROM CONTRACTOR IS INVIOLATION OF U.S. COPYRIGHT LAWSAND WILL BE SUBJECT TO CIVILDAMAGES AND PROSECUTIONS.NEW PV SYSTEM: 6.800 kWpENGINEER OF RECORD12.22.2021DESIGN BY:I.C.M.M.BRICKERRESIDENCE64 MEADOW STNORTHAMPTON, MA 01062APN: M:022B B:0016 L:0001ACDEGHBCFGH1456CONTRACTORC & L POWER SOLUTIONS LLCPHONE:LIC. NO.:DATE:CHECKED BY:REVISIONSHIC. NO.:ELE. NO.:ADDRESS:205 WEST ST,AUBURN, MA 01501, USAwww.greenlancer.comPAPER SIZE: 11" x 17" (ANSI B)8180-EL-A1R-006.00(SHEET 15)RESOURCE DOCUMENT