Loading...
28-080 SM-2022-0004 306 SYLVESTER RD COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 28-080-001 CITY OF NORTHAMPTON Permit: Sheet Metal PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # SM-2022-0004 PERMISSIONISHEREBYGRANTED TO: Project# NEW SINGLE FAMILY HOUSE Contractor: License: Est.Cost: 35000 JESSE FORTIER Const.Class: Exp.Date: Use Group: Owner: BURQUE, ANDREW R &MEGHAN K Lot Size (sq.ft.) Zoning: Applicant: Applicant Address Phone: Insurance: ISSUED ON:02/22/2022 TO PERFORM THE FOLLOWING WORK: HVAC NEW HOUSE POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Gas: Final: Final: Rough Frame: Rough: Fire Department Driveway Final: Fireplace/Chimney: Final: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: 5997 Fees Paid: $50.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner Commonwealth of Massachusetts Sheet Metal Permit FEB 1 8 2022 Date: 02/02/2022 Permit `23 D OF BUILDING INSPECTIONS Estimated Job Cost: $35,000.00 Permit Fee: $ RTHAMPTON,MA01060 Plans Submitted: YES NO Plans Reviewed: YES NO Business License# 824 Applicant License # Business Information: Property Owner/Job Location Information: Name: Jesse Fortier (Rock Valley HVAC) Name: Olde Colonial Building Corp. Street: 1 Main Road Street: 306 Sylvester Rd. City/Town: Westhampton City/Town: Northampton Telephone: (413) 535-7804 Telephone: (413) 977-3290 Photo I.D. required/Copy of Photo I.D. attached: YES NO Staff Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family/ Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft.X over 10,000 sq. ft. Number of Stories:2 Sheet metal work to be completed: New Work: X Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide and install (1)American Standard ducted HVAC system for main house & (1) ducted Mitsubishi heat pump for bonus room above garage. Fabricate and install custom sheet metal duct system, ductwork to be sealed and insulated in accordance with state and local code. All ductwork to be run within conditioned space. AHRI's& heat load attached. ) net ft ILA-d- lti a` c(t'l S i t p ; K (',_ /- w a.((S i / v u `ti ( � 2tii FL . INSURANCE COVERAGE: I have a current liability,insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes •No ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy • Other type of indemnity El Bond El OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner I Agent ❑ Signature of Owner or Owner's Agent By checking this box.,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progress Inspections Date Comments Final Inspection Date Comments Type of License: By Master Title ❑ Master-Restricted City/Town ❑ Journeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number: 564 // 2 t, k Fee$ ❑ Check at www.mass.govldpl W212/ In:pector Signature of Permit A val Load Multizone Summary Report Job: wrightsoft Date: January 11,2022 By: Rock Valley HVAC Inc. 296C Nonotuck Street.Florence,Ma 01062 Phone:(413)535-7804 Email:rodwalleyhvac@yahoo corn Web:wVwvrockvalleyhvac com License:SM2626 Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft' cfm Btuh/ft2 ft3 cfm Btuh/ft' Bonus 7308 0.15 18 1.4 7308 0.08 10 0.2 First Floor 17151 0.12 35 1.4 17151 0.07 19 0.2 Second Floor 10215 0.13 22 1.4 10215 0.07 12 0.2 Entire House 34674 0.13 75 1.4 34674 0.07 40 0.2 Load and AVF Summary ROOM NAME 1 Area Htg load , Clg load Htg AVF Clg AVF ft2 Btuh Btuh cfm cfm Bonus Room 382 3505 2669 171 214 Closet 64 1025 282 50 I 23 Bathroom 72 107 75 5 6 Storage 124 1364 972 66 78 STR3 70 1208 329 59 26 HVAC 100 1002 662 49 53 Bonus 812 8209 4988 400 400 Gathering Room 341 7104 6336 351 447 CL 18 228 54 11 4 WIC 36 455 107 23 8 Mudroom 162 3388 2297 168 162 PWD 30 736 348 36 25 Dining 182 2910 3215 144 227 Foyer 112 1202 300 59 21 Pantry 36 53 0 3 0 STR2 42 62 0 3 0 Living Room 240 4317 3274 214 231 Study 210 3067 2621 152 185 Kitchen 348 2807 3430 139 242 First Floor 1757 26329 21983 1302 1551. Master Bath 90 1595 792 79 56 Bed 3 130 2600 2685 129 189 Hall 128 1186 1001 59 71 Bath 70 867 1205 43 85 Bed 2 179 2606 1748 129 123 Bed 1 145 1681 968 83 68 Laundry 48 71 46 4 3 STR4 45 67 43 3 3 M WIC 48 71 46 4 3 Master 252 3835 4060 190 286 Second Floor 1135 14580 12594 721 889 Entire House 3704 49119 33533 2424 2840 wrightsoft• 2022-Feb-02 06.37:04 �A�Cje ,.,,.. ,...,,..,,......,.., ,.,,,,,,., , Right-S�Uriversal2021 21.0.07 RSU24598 Page 1 A ...tOC Sylvester RdtL.oad)310 Sylvester Rd load.rup Calc=MJ8 Front Door faces:N Project SummaryJob: wrightsoftDate: January 11,2022 Entire House By: Rock Valley HVAC Inc. 296C Nonotuck Street,Florence,Ma 01062 Phone:(413)535-7804 Email:rockvalleyhvac@yahoo.com Web:wmn.rockvalleyhvac.com License:SM2626 Pro-ect Information For: Olde Colonial Building Corp. 306 Sylvester Road,Northampton,Ma 01062 Phone:(413)977-3290 Notes: Desi•n Information Weather: Greenfield(Worcester Dd),MA, US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 °F Daily range M Relative humidity 50 Moisture difference 42 grub Heating Summary Sensible Cooling Equipment Load Sizing Structure 49119 Btuh Structure 33533 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 49119 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 30179 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 5733 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Coolin Area(ft2) 3704 3704 Equipment latent load 5733 Btuh Volume(ft') 34674 34674 Airchanges/hour 0.13 0.07 Equipment Total Load(Sen+Lat) 35912 Btuh Equiv.AVF(cfm) 75 40 Req.total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 cfm Actual airflow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfrn/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t ele- w h o rigtsft" Rig ht-Site®Uriversa1202121.0.07RSU24598 2022-Feb-020Page1 ACCA ...\OC Sylvester Rd\Load1310 Sylvester Rd load.np Calc=MJ8 Front Door faces:N N Level 1 I r 5 QS Garage as S It."6 �S ae1”..lyrl„unt C. R a PVOD WIC - I MudraDm Y • STR rj____ CD 5 f .A'. I Living Room as Kitchen �* S„pp'y wsmadatf �ar a R R<4-,,,,1 MINIM STR2 Study DNng Foyer ii S t'-1' +� v Job#: Rock Valley HVAC Inc. Scale: 1 : 147 Performed for: Page 2 Olde Colonial Building Corp. 296C Nonotuck Street Right-Suite®Universal 2021 306 Sylvester Road Florence,Ma 01062 21.0.07 RSU24598 Northampton,Ma 01062 Phone:(413)535-7804 2022-Feb-02 06:37:52 Phone:(413)977-3290 www.rockvalleyhvac.com rockvalleyhvac@yahoo.com d\Load\3lo Sylvester Rd load.rup 4 . , Level 2 St 1 F Bonus Room Storage It 51i mil 5. I ._-__ 1� ■I Bathroom 1 1 � ki a., 11 STR3 5 tZ7 J C7 Dw3{6,_ , �S _h,S (A. Mastl-Bath lied 1 �/n' Bed 2 `�"��5 �• OP 40 M WlC Laundry ' - m - - Batt, s„pp'Y f. ST24 Hall at 4 v r n iliim Master Oper Bed 3 c� Job#: Rock Valley HVAC Inc. Scale: 1 : 147 Performed for: Page 1 Olde Colonial Building Corp. 296C Nonotuck Street Right-Suite®Universal 2021 306 Sylvester Road Florence,Ma 01062 21.0.07 RSU24598 Northampton,Ma 01062 Phone:(413)535-7804 2022-Feb-02 06:37:52 Phone:(413)977-3290 www.rockvalleyhvac.com rockvalleyhvac@yahoo.com ...d\Load\310 Sylvester Rd load.rup Eligible for Federal Tax Credit ..n/ CERTIFIED° www.ahridirectory.org Certificate of Product Rat I n s g AHRI Certified Reference Number:204744689 Date:02-02-2022 Model Status:Active AHRI Type: RCU-A-CB(Split System:Air-Cooled Condensing Unit,Coil with Blower) Series:SILVER 16 Outdoor Unit Brand Name:AMERICAN STANDARD Outdoor Unit Model Number (Condenser or Single Package):4A7A6036J1 Indoor Unit Model Number(Evaporator and/or Air Handler):4TXCB006DS3 Furnace Model Number:S9V2B080U4VSA Region: All(AK,AL,AR,AZ,CA,CO,CT, DC, DE, FL,GA, HI, ID, IL, IA, IN,KS,KY, LA, MA,MD, ME,MI, MN,MO,MS, MT, NC, ND,NE,NH,NJ, NM, NV, NY,OH,OK,OR, PA, RI,SC,SD,TN,TX,UT,VA,VT,WA,WV,WI,WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1,2015 are eligible to be installed in all regions until June 30,2016.Beginning July 1,2016 central air conditioners can only be installed in region(s)for which they meet the regional efficiency requirement. The manufacturer of this AMERICAN STANDARD product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240-2017 with Addendum 1, Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh:36200 SEER: 16.50 EER(A2)-Single or High Stage(95F): 14.00 1-"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better'' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2022Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 132882757650736837 Eligible for Federal Tax Credit. ti..I CERTI FIE D`t www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:204627055 Date:02-02-2022 Model Status:Active AHRI Type:HRCU-A-CB(Mini-Split System:Heat Pump with Outdoor Unit-Air-Source,Ducted) Outdoor Unit Brand Name: Mitsubishi Electric Outdoor Unit Model Number:SUZ-KAl2NAHZ Indoor Type: Mini-Splits(Ducted) Indoor Model Number(s):SVZ-KP12NA Rated as follows in accordance with the latest edition of AHRI 210/240-2017 with Addendum 1, Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh : 12000 SEER: 19.00 EER(A2)-Single or High Stage(95F): 13.90 Heating Capacity(H12)-Single or High Stage(47F): 15000 HSPF(Region IV): 10.20 Sold in?:USA,Canada RTIFIE [ 111* �■ E, www. ahridirectory. o ; t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life hewer" and enter the AHRI Certified Reference Number and the date on which the certificate was issued. which is listed above,and the Certificate No.,which is listed at bottom right. ©2022Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 132882757886767070