Loading...
38B-163 BP-2022-0161 20 FORT ST COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 38B-163-001 CITY OF NORTHAMPTON Permit: Solar Build PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit# BP-2022-0161 PERMISSIONIS HEREBY GRANTED TO: Project# 2022 SOLAR Contractor: License: NORTHEAST SOLAR DESIGN Est. Cost: 23028 ASSOCIATES LLC 106113 Const.Class: Exp.Date:06/07/2023 SCHLUENZ, JONATHAN, K&JONATHAN D Use Group: Owner: RICHMOND Lot Size (sq.ft.) Zoning: URB Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC Applicant Address Phone: Insurance: 136 Elm St 4132476045 WC201900019843 HATFIELD, MA 01038 ISSUED ON:02/22/2022 TO PERFORM THE FOLLOWING WORK: INSTALL 16 PANEL 6.96 KW ROOF MOUNTED SOLAR SYTEM POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Gas: Final: Final: Rough Frame: Rough: Fire Department Driveway Final: Fireplace/Chimney: Final: Oil: Insulation: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: f . • r • Ste► ' • Fees Paid: $75.00 212 Maui Street, Phone(413)587-1240,Fax:(413)587-1272 Office of the Buildinu Commissioner 3 ,V\tt..&€vl—a r . : Department use only City of Norhampton _ tl' cop/omit Building DeparrnentFEB tvs e,Curti Pen 212 Main Street 1 8 2022 sawscSapSc Avadabltty Room 100 . waitrrw tl Avedabdtty Northampton. MAb T smut Structural Fans phone 413.587.1240 f-ax_413 5 g oEcT PgyS Nina APPUCATION TO CONSTRUCT,ALTER.REPAIR.RENOVATE OR DEMOLISH AONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION This section to be completed by office 1 I ProoettY Addtlii 20 Fort St Map Lot Unit Northampton MA 01060 s, Overlay District eat IL Oiliest Cs Novick_- SECTION 2 -PROPERTY OWNERSHIPAUTHORIZED AGENT 2.1 Owner of Record. 20 Fort St Jon Schluenz Northampton MA 01060 %arra( r tt---- Carom Mallon Addnus• / SIGNf (413)561-6311 .., tevnpMrq s.311. No • :st • -r 136 Elm St. Hatfield. MA 01038 %arr€t Oar'rtl 0 r C,.r•nr tliai nG ACdrn s- '�.. 47 r 413-247-6045 ' -44,4 1 Item Estimated Cost(Dcears)to be Of• ca ..,se Or iv cornoeted by perm,apcccant • Building ?a)Building Permit Gee 2. Electrical (b)Estumated Toter Cost of — Construction from 16) 3. Plumbing Burtdtng Permit Fee 4. Mechanical(HVACI # 5.Firs Protection 6. Total=(1 +2'P 3'4.51 i $23,028 Check Number e2/C/ / This Section for Official. Use Only Building Permit Number: 61-gil A- I Ci I Date Issued: --�__ �-- as ate, Sionan,re: / , 7 1 6 H,„,,t;^, :;.1^r.�s.n^.-•..„ape Huteltvt :4te 5CTION S-DESCRIPTION OF PROPOSED WORK(check all aophcable) New House Addition El Replacement Windows Aiteretionlsl E Roofing 1 Or Doors 0 Accessory Bldg. —1 Demolition ❑ New Signs ;t IJ Decks I Siding IL;j Other;X? One'Descriptor M i'-ceased Install 16 solar panels on Roof Wes: Ateraton cf existing erpprn Yes— No Adc,r•g new bedroom Yes No Attached Narrative Renavatng un`.n shed basement Yes No Pans Attached Roll -Sheet a.If Mira house and or addition to existing housino.corntoiete the following: a. Use of building: One Fern _ Two=army Ctner O. Nurrcet of rooms In each famey unit: Number of 9athroorrs_ -. Is trere a garage attached? .. Prooased Sauare'ootage of new construction Omens.ons e. Nurrcer of stones' f. Metttoc of heating? Fireplaces or Woocstoves Number of each g. Energy Conservation Corroiarce —Masscreck Energy Compliance form attadners?_ r. Type of oor•structior Is construction•apt^n 100 ft.of wetlands?__Yes No. Is cansWc6er wthm 100 yr. floodplain Yes No Depth of basement or oe ler floor oe ow Tinisnee grade t. W n building cceforrn to the Budding and Zoning regulations? Yes No. . Sectrc Tani( City Sewer prolate well Cly water Sucoly SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT l Jon Schluenz ,as Owner of the sect property hereby autronze Northeast Solar to act on my ben all m feed work aulhonzeo by this building perrnt abolcation. Si azure of. ddlre I. Gregory Garrison/Northeast Solar ,as ornerA.tnonzec Agent hereby dec,are that the statements and ,nformat n on the foregong applicabon are true anc a_a.rate to the cest o'my (ncrwlecge and be of Signed 4noer the aa.-s arc penalties of penury. Gregory Garrison I , I i ______ Prnt rsa,',e � P 1 . . I_ IQ`�' -- Slgna:wr oferA3rrd glr , . SEC ri O N j -CONS TRUCTION SERVICES f}.1 L sensed Construction Supervisor: Not Applicable 0 Phill:p Baunsgard dzns..of..Licerse Holder. CS106113 License Nurrber - = - 1ia� Ma 0 40 6/7/23 !W,L. Expire oast] 413-247-6045 9. Registered Home Improvement Contractor: Not Applicable 0 `,ioi . least Solar 1E 3641 Comps^y Name. Regislratror Number 13 6 Elm S . Hat - ld Ma 01038 7/13/23 .Actress Expiration Date Telephone 413-247-6045 } a i SECTION 10- • ; • • PENSATION INSURANCE AFFIDAVIT(M G.h.c.152, 25C(6)) Workers Compensation Insurance affidavit must be completed and subntittad with this applicator. Failure to provide this affidavit will result in the denial of the issuance of the building perms. Signed Affidavit Attached Yes.....-.X] No 0 • 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(I) or two(2)families and to allow such homemvncr to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor. CN1R 750. Sixth Edition Section 105.1.5,1, Definition of Homeowner: Person(s) who own a parcel of land on which hc;she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and!or farm structures. A person who constructs more than one home In a two-year period shall not be considered a homeowner. Such"homeowner";hall submit to the Building Official,on a form acceptable to the Building Official,that hershe shall be resnonslble for all such work performed under the building permit. As acting Copstrec ion Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for persons) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature_-_ --- City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111 , S 150A. Address of the work: f010+- por-t&lametaii The debris will be transported by: X.)Q 12ti� � '( °vim (4?gt&) The debris will be received by: l-50- 14e0 Building permit number: Name of Permit Applicant : �X,� � 6,12- /22 Date ature of Per Applicant The Commonwealth of Massachusetts Department of Industrial Accidents S7 .-t Office of investigations i. = 11_ 1 Congress Suet, Suite 100 Boston,MA 02114-2017 ,,.-av''i www.mass.gov/dia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print L egibly Business/Organization Name:Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield,Ma 01038 Phone#:413-247-6045 Are you an employer?Check the approp riate box: Business Type(required): 1. J❑ I am a employer with 17 employees(full and/ 5. 0 Retail or part-time).* 6. 0Restaurant3ar/EatingEstablishment 2.0 I am a sole proprietor or partnership and have no 7. ❑Office and/or Sales(incl.real estate, auto, etc.) employees working for me in any capacity. [N o workers' comp.insurance required] 8. ❑Non-profit 3.El We are a corporation and its officers have exercised 9. ❑Entertainment. their right of exemption per c. 152,§1(4), and we have 10.❑Manufacturing no employees.[N o workers'comp.insurance required]** 4.❑ We are a non-profitorganiaati on, staffed by volunteers, 11.1:1Health Care , I I with no employees.[No workers' camp. insurance req.] 120Other S-Q(O( [ltj}'(W(/( *Any applicant that clucks box#1 mist also fill cut the sectianbelow shaving their workers'compensation policy information **If the corporate ofcea have exempted themselves,but the corporation has other employees,aworkers'compensation policy is required and such an oiganization should check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance C ompany N ame:New York Marine and General Insurance Company Insurer's Address: 20 Fort St City/state/Zip: Northampton MA 01060 Policy#or S elf-ins.Lic. #WC201900019843 Expiration Date: 7/8/2022 . Attach a copy of the workers' comp ensationp olicy declaration page(showing the policy number and exp iration date). Failure to secure coverage as required under Section25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of aSTOP WORK ORDER and afine of up to$250.00 a day against the violator. B e advised that a copy of this statement maybe forwarded to the Office of Investigations of the DIA for i ance coverage verification. I do hereby certify,under the ,, .,.d , ., of,r wy that the information provided above is true and correct. Signature: I, D ate: 1/12/2022 Phone#:413-247-6045 /I4, !,r N Official use only. Do not write in ;. area, to be completed by city or town official City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Budding Department 3. City/Town Clerk 4.Licensing Board 5. Selectmen's Office 6.Other Contact Person: Phone#: www.nmas s gov/dia -�—.4N NORTSOL-01 JHOGAN A�--- CERTIFICATE OF LIABILITY INSURANCE DATE 7/9/2021 ) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: EPIC Insurance Brokers&Consultants PHONE FAX 144 Gould Street Suite 100 (NC,No,Exq:(781)455-0700 (Afc,No):(781)449-8976 Needham,MA 02494 n pjIEgg:certificates@roblininsurance.com INSURERS)AFFORDING COVERAGE NAIC# INSURER A:Gotham Insurance Company _ INSURED INSURER B:Safety Insurance Company -39454 Northeast Solar Design Associates,LLC INSURER C:Capitol Indemnity Corporation 136 Elm Street INSURER 0:Nevi York Marine and General Insurance Company 16608 Hatfield,MA 01038 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER W POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSD VO (MM W/DD/YYYYI (MM/DDIYYI A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE X OCCUR PK201900018166 7/8/2021 7/8/2022 DAMAGE TO RENTED 300,000 PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 5,000 PERSONAL 8 ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY X JPCT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ B AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ ANY AUTO 5909629 7/8/2021 7/8/2022 BODILY INJURY(Per person) $ _ OWNED SCHEDULED AUTOSRE� ONLY X AUTOS i BODILY INJURY(Per accident) $ X AUTOS ONLY X AUOTOS ONLY PROPERTY ardent DAMAGE $ C X UMBRELLA UAB X OCCUR EACH OCCURRENCE $ 1,000,000 EXCESS LIAB CLAIMS-MADE 7/8/2021 7/8/2022 AGGREGATE $ 1,000,000 DED X RETENTION$ 10,000 $ D WORKERS COMPENSATION X PER ATUTE OOTH _ AND EMPLOYERS'LIABILITY I WC201900019843 7/8/2021 7/8/2022 1,000,000 ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N N/A ---- (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE. $ 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Property PK201900018166 7/8/2021 7/8/2022 BPP i 225,000 A Property PK201900018166 7/8/2021 7/8/2022 BI I 350,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is requklM) Issued as evidence of Insurance. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Cityof Northampton THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN p ACCORDANCE WITH THE POLICY PROVISIONS. 210 Main Street Northampton,MA 01060 AUTHORIZED REPRESENTATIVE ACORD 25(2016/03) ©1988-2015 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Office of Consumer Affairs and Business Regulation 1000 Washington Street - Suite 710 Boston, Massachusetts 02118 Home Improvement Contractor Registration Type: LLC Registration: 169641 NORTHEAST SOLAR DESIGN ASSOCIATES, LLC Expiration: 07/13/2023 136 ELM ST HATFIELD,MA 01038 Update Address and Return Card. Office of Consumer Affairs&Business Regulation HOME IMPROVEMENT CONTRACTOR Registration valid for individual use only TYPE:LLC before the exp ation date. If found return to: Registration Expiration Office of Co mer Affai and Business Regulation 169641 07/13/2023 1000 Washin n Street Suite 710 NORTHEAST SOLAR DESIGN ASSOCIATES,LLC Boston,MA 8 GREGORY GARRISON 136 ELM ST HATFIELD,MA 01038 Undersecretary Not II Without signature IPSCommonwealth of Massachusetts Division of Professional Licensure Board of Building Regulations and Standards C onstruCttin1Supervisor CS-106113 Tres:06/07/2023 PHILLIP BAUNSGARD:,J . 41 HEATH ROAD140 COLRAIN MA411340 • -- • r/16Is-,:,1«01\. Commissioner eta / pc'nx.uoL +E" r AVENUE °_ iolkrAIMSOS Roof mounted solar arraywith i _ ,• .t 16x LG modules and ,,e A_ 16x Enphase IQ7PIus-72-2-US yik, microinverters . *Ay ., ,,,„ . { 4L r_, ir,, .., ,F 411101141411, . -1 . • 'N. ' ''St A.: . '- - P' Oh: .. sit4i. ,ing-4):,,t: ilicsost -„, .rt„ )4yy� a . 4 . Y -4 _ boa ' , ^7 Utility meter and .h,� . ; ,� __ ; _,.; . . _ : _.. - ,_ } ,, . utility accessible ,s solar AC disconnect t on exterior wall 0. a ',M*** - Main electric = panel in �.� basement ` -t. ik; - --s- .. ‘N.N., .:1 N,\siiitil(ittattibi. aiiiiiii ilk Jon K Schluenz 20 Fort St 4 Northampton, Ma 01060 Northeast Solar Vreeland Design Associates An integrative approach to design engineering and site planning Date: February 8,2022 To: Justin Annis NorthEast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Jon Schluenz, 20 Fort Street,Northampton, MA: Structural assessment of existing house roof to support proposed solar array. I have investigated the existing house roof framing for the proposed PV solar panel installation. According to the Assessor's property card,the 2-story, 24'x 28' house was constructed in 1925. 16 PV solar panels are to be installed on the southeast facing roof. The original rafters are full dimension 2x6 installed approximately 24"on-center, spanning 11'-8"with a roof pitch of 8/12. The rafters are supported on 2x4 exterior walls with 2x6 attic floor joists installed 16"on-center secured to the walls to prevent the roof from spreading. During a recent renovation the attic joists were sistered with new 2x6 and a 2x4 kneewall install approximately 5' in from the exterior walls. The roofing is composite asphalt shingles. I have reviewed the mounting details for the proposed array. Based on my calculations and a PV solar panel unit weight of 45±lbs, with the attachment points of the array placed at a maximum of 4' on center and staggered to minimize the load to any one rafter,the existing roof framing is adequate to support the proposed PV solar array and the snow and wind load requirements of the current MA State Building Code for the City of Northampton. Please contact me if you have any questions or need additional information. P �OF MgSS Sincerely, c'DAVID A. y VREELAND 4 , f CD ot"C�l v No 46317 "' David Vreeland, PE lbAcisTER0\.4 Vreeland Design Associates FSS/ONALE��' 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 . . :_...., LGNON®R . . LG435QAC-A6 Preliminary 435W • LG NeON®R is powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on - — __ the front maximizes the utilization of light and enhances reliability. - - - - �� LG NeON®R is a result of LG's efforts to increase customer's _ values beyond efficiency.LG NeON®R features enhanced durability, _ performance under real-world conditions,an enhanced warranty r and aesthetic design suitable for roofs. ____ ,. . , . IDE ( C ® uS CE w, .. �,� ,. .. , .7,..______ . •. . . 251 YEAR PRODUCT•PERFORMANCE•LABOR WviPPINTY Features Roof Aesthetics in 25-YearLimited Product Warranty LG NeON®R has been designed with "" The NeON®R is covered by a 25-year limited aesthetics in mind:the lack of any product warranty.In addition,up to$450 of electrodes on the front creates an labor costs will be covered in the rare case that improved,modern aesthetic. a module needs to be repaired or replaced. Enhanced Performance Warranty More generation per square meter 5 The LG NeON®R has an enhanced 6 The LG NeON®R has been designed to performance warranty.After 25 years, significantly enhance its output,making LG NeON®R is guaranteed at least it efficient even in limited space. 92.5%of initial performance. When you go solar, ask for the brand you can trust: LG Solar About LG a in Electronics p USA, Inc. 0 LG LG Electronics is a global leader electronic products in the clean energy markets by offering solar PV panels and energy storage systems.The company first embarked on a solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoX•series to the market,which is now available in 32 countries.The NeON'(previous MonoX'NeON),Ne0Ne2,NeONa2 BiFacial won the"Intersolar Life 5 Good AWARD'in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. LG NeON'R Preliminary LG435QAC-A6 General Data Electrical Properties(STC*) CeU Properties(Material/Type) Monocrystalline/N-type Model LG435QAC-A6 Cell Maher LG Maximus Power(Pmax) [W] 435 Cell Configuration 66 Cells(6 x 11) _ MPP Voltage(Vmpp) M 41.1 Module Dimensions(L x W x H) 1,910mm x 1,042mm x 40mm MPP Curtest(Impp) [A] 10.59 Weight 20.5 kg Open Circuit Voltage(Voc,±5%) M 48.0 Glass(Material) Tempered Glass with AR Coating Short Circuit Current(Isc,t5%) [A] 11 20 Backsheet(Color) White Module Efficiency [%] 21.9 Frame(Material) Anodized Aluminium Power Tolerance [%] 0-+3 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes •STC(Standard Test Condition),Irradiance 1000 W/m',Cell temperature 25'C,AM 1.5 Measure Tolerance:t 3% Cables(Length) 1,250mm x 2EA Connector(Type/Maker) MC 4/MC Operating Conditions Operating Temperature' [°C] -40-+85 Certifications and Warranty Maximum System Voltage [V] 1,000 1EC61215-1/-1-1/2:2016,IEC 61730-1/2:2016, - - UL 61730-1:2017,UL 61730-2:2017 Max mum Series Fuse Rating [A] 20 Certifications- iso 9001,15014W1,Aso s0001 Mechanical Test Load-(Front) [Pa/psf] 5,400 OHSAS 18001 Mechanical Test Load-(Rear) [Pa/psf] 4,000 Salt Mist Corrosion Test IEC 61701:2011 Severity 6 'The operating ambient temperature of these devices may exceed 40'C at full load for all wire saes if is determined - - suitable in the field use application. Ammonia Corrosion Test IEC 62716:2013 "Based on IEC 61215-2:2016(Test Load-Design Load a Safety Factor(1.5)) Hail Test 25mm(1')diameter at 23m/s(52mph) Module Fire Performance Type 1(UL 61730) Packaging Configuration Fire Rating Class C(UL 790,ULC/ORD C 1703) Number of Modules per Pallet [EA] , 25 Solar Module Product Warranty 25 Years Number of Modules per 40'Container _.. -J 600 Solar Module Output Warranty Linear Warranty' Number of Modules per 53'Container [EA] TOD 'Improved:1"year 98 5%,from 2-24th year-0.2596/year down,92.5%at year 25 Packaging Box Dimensions(L x W x H) [mm] 1,960 x 1,120 x 1,221 •In Progress Packaging Box Dimensions(L x W x H) [in1 77,2 x 44.1 x 48.1 Temperature Characteristics Packaging Box Gross Weight [kg] 549 NMOT ['C] 44±3 Packaging Box Gross Weight [lb] 1,210 Pmax [%PC] -0.29 Voc [%/°C] -0.24 Dimensions(mm/inch) lsc [%/°C] 0.04 'NMOT(Nominal Module Operating Temperature):Irradiance 800 W/m',Ambient temperature 20'C, Wind speed 1 m/s,Spectrum AM 1.5 1042_0/41,0(51e of 51nrt side) _ Electrical Properties(NMOT) 17so/fig Model LG435Q/6C-A6 .11.-...11.10020/39.4(oimu n(Mcrae holes) 600 -5) Maximum Power(Pmax) ['N] 330 ' / •• 16-81:1x 3A/0.3x0.1 MPP Voltage(Vmpp) [V] 38.8 loai,Holes MPP Current(Impp) [A] 8,49 8-043/02 (-) (+) Grounding Open Circuit Voltage(Vac) [V] 45.8 0.5 Short Circuit Current(1st) [A] 9,02 Mounting Ho4-asxl2o/oles • 1250.0/49.2 I l-V Curves Came Length g 12.0- • 1 2 1000W . atl 10.0- d 800W . 8.0- 600W t 6,0- a i 400W u 4.0- -.....\\N‘\\\\. 200w 2.0 0.0 Qo . 0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 i t: ., r Voltage[V] ® LG Electronics USA,Inc. Product specifications are subject to change without notice. LG Solar Business Division LG435QAC-A6 pdf 2000 Mhire,IL Drive 121020 Lincolnshire,L 60069 Life's Good www.lg-solarcom 0 2020 LG Electronics USA,Inc.All rights reserved. Tech Brief . ..e4wit,, IRONRIDGE XR Rail Family Solar Is Not Always Sunny 17:)."'L ..2, Over their lifetime, solar panels experience countless ,. 71: '' extreme weather events. Not just the worst storms in years, t,` {� but the worst storms in 40 years. High winds capable of # ripping panels from a roof, and snowfalls weighing ��, t enough to buckle a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect ` _, against buckling and safely and efficiently it-•„„:„ .,„,„.,_ transfer loads into the building structure. ,. , Their superior spanning capability requires fewer roof attachments, -., reducing the number of roof ` penetrations and the amount of installation time. • 9 ' #10**,,,,,, 1 „. „0,,.....................„„„4„,„ ,, ,,,, . , \'''3 ,, Y: ' y Force-Stabilizing Curve J' s' k, Sloped roofs generate both vertical and lateral forces on mounting rails which can cause them to bend and twist.The curved shape of XR Rails :.�tx is specially designed to increase strength in both "� ° directions while resisting the twisting.This unique a , ° feature ensures greater security during extreme it-l';- - .V weather and a longer system lifetime. '4.CJ mfi: l Compatible with Flat&Pitched Roofs I Corrosion-Resistant Materials XR Rails are IronRidge offers All XR Rails are made of 6000-series k rcompatible with a range of tilt leg aluminum alloy,then protected with an FlashFoot and 1--1options for flat anodized finish.Anodizing prevents surfaceIl 1 other pitched roof 1 I roof mounting and structural corrosion,while also providing attachments. applications. a more attractive appearance. Tech Brief XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. '1.1 " "1i -----ftmmemmum""mft!!1_, XR10 XR100 XR1000 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails.It's built to handle no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. • 6'spanning capability • 10'spanning capability • 12'spanning capability • Moderate load capability • Heavy load capability • Extreme load capability • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish • Internal splices available • Internal splices available • Internal splices available Rail Selection The table below was prepared in compliance with applicable engineering codes and standards.* Values are based on the following criteria:ASCE 7-16, Gable Roof Flush Mount, Roof Zones 1 & 2e, Exposure B, Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed certification letters. Load Rail Span Snow (PSF) Wind (MPH) 5'4" 6' 8' 10' 12' 90 120 %. None 140 XR10 XR10 -1000 160 - 90 120 20 140 160 90 30 160 90 40 160 120 160 `Table is meant to be a simplified span chart for conveying general rail capabilities.Use approved certification letters for actual design guidance. ©2020 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.20 ,��_ - .... a.. S UNM � - INSTALLATION MADE EZ & EZRI EZ EZR SunModo's best-selling EZ Roof Mount is the industry standard for PV system The EZ & EZR Advantage mounting on any composite ✓ Leak-proof design protects shingle roof. sealing points from elements. ✓ ICC Certified for both rafter and Now, SunModo introduces a decking solution. smaller footprint, EZR Roof ✓ Exceptional resistance to corrosion Mount flashing, where truss and wear. anchoring can be assured, embossed design minimizes ✓ A wide variety of L-feet and standoffs available. bending, and only one tool is needed. ✓ Surprisingly easy to install! Key Features of EZ and EZR simmeAMI • 1 1 1 1 I MODEL EZ Mount EZR Mount o Cit1 L J 1 1 1 1 Raised teardrop design diverts water from the roof penetration. 1 I 1 360-degree L foot positioning, serrated L foot on both sides for rail mounting. A wide variety of L-feet and standoffs available. '41( 1 1 1 1 1 1 I 1 I 1 1 Versatile mounting option includes direct-to- decking for easy installation. 1 1 Stamped emboss features stiffen the flashing to minimize bending. 1 1 I 1 1 1 1 1 1 Only one tool is needed. l 1 1 1 1 I Technical Data Application Composite shingle Material High grade aluminum, 304 stainless steel hardware Finish Clear anodized, silver or black powder coated Flashing Size EZ Roof Mount: 10.00 x 12.48 x 0.04 inches EZR Roof Mount: 8.00 x 11 .38 x 0.03 inches Roof Attachment EZ Roof Mount: Rafter and decking EZR Roof Mount: Rafter only Structural Integrity IBC and IRC compliant Warranty 20 years SunModo, Corp. Vancouver, WA., USA • www.sunmodo.com • 360.844.0048 • info@sunmodo.com