Loading...
Lesko Electrical PermitApplication (2)_compressed (1)Commonwealth of Massachusetts Department of Fire Services BOARD OF FIRE PREVENTION REGULATIONS Official Use Only Permit No. Occupancy and Fee Checked [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC), 527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: City or Town of: To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location (Street & Number) Owner or Tenant Telephone No. Owner’s Address Is this permit in conjunction with a building permit? Yes No (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps / Volts Overhead Undgrd No. of Meters New Service Amps / Volts Overhead Undgrd No. of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Completion of the following table may be waived by the Inspector of Wires. No. of Recessed Luminaires No. of Ceil.-Susp. (Paddle) Fans No. of Transformers Total KVA No. of Luminaire Outlets No. of Hot Tubs Generators KVA No. of Luminaires Swimming Pool Abovegrnd. In- grnd. No. of Emergency Lighting Battery Units No. of Receptacle Outlets No. of Oil Burners FIRE ALARMS No. of Zones No. of Switches No. of Gas Burners No. of Detection and Initiating Devices No. of Ranges No. of Air Cond. Total Tons No. of Alerting Devices No. of Waste Disposers Heat Pump Totals:Number Tons KW No. of Self-Contained Detection/Alerting Devices No. of Dishwashers Space/Area Heating KW Local Municipal Connection Other No. of Dryers Heating Appliances KW Security Systems:* No. of Devices or Equivalent No. of Water Heaters KW No. of Signs No. of Ballasts Data Wiring: No. of Devices or Equivalent No. Hydromassage Bathtubs No. of Motors Total HP Telecommunications Wiring: No. of Devices or Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10, and upon completion. INSURANCE COVERAGE: Unless waived by the owner, no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including “completed operation” coverage or its substantial equivalent. The undersigned certifies that such coverage is in force, and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE BOND OTHER (Specify:) I certify, under the pains and penalties of perjury, that the information on this application is true and complete. FIRM NAME: LIC. NO.: Licensee: Signature LIC. NO.: Bus. Tel. No.: (If applicable, enter “exempt” in the license number line.) Address: Alt. Tel. No.: *Per M.G.L. c. 147, s. 57-61, security work requires Department of Public Safety “S” License: Lic. No. OWNER’S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the (check one) owner owner’s agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ Northampton January 14, 2022 20 Prospect Street Jill Lesko 205 Prospect Street Northampton, MA 01060 413-584-5195 x Installation of a safe and code-compliant, grid-tied PV Solar System on a residential rooftop 19,000 Empower Energy Solutions Inc Lando Bates 51 Assabet Dr Northborough MA 01532-2600 8209 A1 20559 A 413-584-5195 DRIVEWAY FOHPROSPECT STM INVAC MSP B μ AC LEGEND M INV AC MSP B D LC μ UTILITY METER INVERTER AC DISCONNECT MAIN SERVICE PANEL DC JUNCTION BOX MONITORING UNIT DISTRIBUTION PANEL LOAD CENTER CONDUIT FENCE SCALE: 1" = 15' N S E W ATS AUTOMATIC TRANSFER SWITCH LESKO, JILL LESKO RESIDENCE 205 PROSPECT ST HOME NORTHAMPTON, MA,01060 413-584-5195 RACKING: IRONRIDGE XR-100 JOB NUMBER: 1037 UTILITY: NG OWNER:DESCRIPTION:DESIGNED BY: REV:DATE: 18/11/2021 PAGE NAME: PAGE: HA INVERTER: (1) SOLAREDGE INVERTER SE6000H-US (6.00 KW) 6.00 kW AC SITE PLAN PV2REVIEW BY: MS6.65 kW DC ROOF SOLAR SYSTEM MODULES: (19) LONGI LR4 - 60HPB 350M UTILITY ACCT #:88152-60021 Signed 11-19-21 INVERTERSsolaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEARWARRANTY MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V3300 @ 208V 5000 6000 @ 240V5000 @ 208V 7600 10000 11400 @ 240V10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)HzMaximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 WMaximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 VdcNominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 AdcMaximum Input Current @208V(2)-9 -13.5 --27 AdcMax. Input Short Circuit Current 45 Adc Reverse-Polarity Protection YesGround-Fault Isolation Detection 600k SensitivityMaximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Inverterwith HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mmWeight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box(4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverterwith HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2020/V01/ENG NAM. Subject to change without notice. How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills POWER OPTIMIZERsolaredge.com PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Power Optimizer For North America P370 / P400 / P401 / P485 / P505 25 YEARWARRANTY © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 04/2021 DS-000044-2.0-NA. Subject to change without notice. (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf(7) It is not allowed to mix P485/P505 with P370/P400/P401 in one string(8) If the inverters rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf (9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W(10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W Power OptimizerFor North America P370 / P400 / P401 / P485 / P505 Optimizer model(typical module compatibility) P370(for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P401(for high power 60 and 72 cell modules) P485 (for high-voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1)370 400 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 60 80 60 125(2)83(2)Vdc MPPT Operating Range 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE Photovoltaic Rapid Shutdown System NEC 2014, 2017 & 2020 NEC 2014, 2017 & 2020 NEC 2014, 2017 & 2020 EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 /5.1 x 6 x 1.16 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)655 / 1.4 750 / 1.7 655 / 1.4 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52, 0.9 / 2.95(4)0.16 / 0.52 0.16 / 0.52, 0.9 / 2.95 (4)0.16 / 0.52 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 1.2 / 3.9 m / ft Operating Temperature Range(5) -40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed(2) NEC 2017 requires max input voltage be not more than 80V(3) For other connector types please contact SolarEdge(4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals(5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter(6)(7)Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P370, P400, P401 8 10 18P485, P505 6 8 14Maximum String Length (Power Optimizers)25 25 50 Maximum Nominal Power per String 5700(8) (6000 with SE7600-US - SE11400-US)5250(8)6000(9)12750(10)W Parallel Strings of Different Lengths or Orientations Yes