Loading...
36-381 (2) SM-2022-0001 238 EMERSON WAY COMMONWEALTH OF MASSACHUSETTS Map:Block:Lot: 36-381-001 CITY OF NORTHAMPTON Permit: Sheet Metal PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) BUILDING PERMIT Permit # SM-2022-0001 PERMISSION IS HEREBY GRANTED TO: Project# SHEET METAL Contractor: License: Est. Cost: 25000 ROCK VALLEY HVAC Const.Class: Exp.Date: Use Group: Owner: STARCK, ANN-MARIE &CRAIG F SMITH Lot Size (sq.ft.) Zoning: SR Applicant: ROCK VALLEY HVAC Applicant Address Phone: Insurance: 296C NONOTUCK STREET 4135357804 FLORENCE, MA 01062 ISSUED ON:01/03/2022 TO PERFORM THE FOLLOWING WORK: HVAC POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: fAjovi5, anti, • Fees Paid: $50.00 212 Main Street, Phone(413)587-1240,Fax:(413)587-1272 Office of the Building Commissioner Commonwealth of Massachusetts Sheet Metal Permit Date: 11/19/2021 ,/ �` 1 Permit# Estimated Job Cost: $25,000.00 ,J4 a �. e�rmit ee: $ ° -°� iC'��7 N , Plans Submitted: YES : Na 3 2047 Ian Reviewed: YES NO y44n;NG Business License# 824 lA 0,,,a;s'Ocr Applicant License# Business Information: rojerty Owner/Job Location Information: Name: Jesse Fortier(Rock Valley HVAC) Name: Wright Builders Street: 296C Nonotuck Street Street: 238 Emerson Way City/Town: Florence City/Town: Northampton Telephone: (413) 535-7804 Telephone: (413) 586-8287 Photo I.D. required/Copy of Photo I.D. attached: YES NO Stall Initial J-1 /M-1-unrestricted license J-2 /M-2-restricted to dwellings 3-stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other Square Footage: under 10,000 sq. ft. Y- over 10,000 sq. ft. Number of Stories: 1 Sheet metal work to be completed: New Work: K' Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide and install (3) ducted Mitsubishi air handlers, (1)for main house, (1)for master wing, & (1)for basement zone. Fabricate and install custom sheet metal duct system, ductwork to be sized according to Manual J 8rh edition heat load calculation. Ductwork to be sealed in accordance with local code. Ductwork to be wrapped with R6 insulation. INSURANCE COVERAGE: I have a current liability insurance policy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes •No ❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy • Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws, and that my signature on this permit application waives this requirement. Check One Only ~� —�---- Owner • Agent El Signature of Owner or Owner's Agent By checking this boxy,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Progress Inspections Date Comments Final Inspection Date Comments Type of License: By Master Title ❑ Master-Restricted City/Town ❑ Journeyperson Signature of Licensee Permit# ❑ Journeyperson-Restricted License Number: 5 6 a- Fee$ Check at www.mass.qov/dpl if op I %is .4-SLi 3 2a In- .ector Signature of Permit A oval Load Multizone SummaryReport �°�Re wrightsoft p Date: August 10,2021 By: Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HIM ft3 cfm Btuh/ft2 ft3 cfm Btuh/ft' Basement 6345 0.19 20 1.9 6345 0.10 11 0.2 Main House 11718 0.14 27 1.9 11718 0.07 15 0.2 Master Zone 5139 0.12 10 1.9 5139 0.06 5 0.2 (Unconditioned) 0 0 0 0 0 0 0 0 Entire House 23202 0.15 58 1.9 23202 0.08 31 0.2 Load and AVF Summary ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2 Btuh Btuh cfm cfm Bonus Room 325 2828 1390 129 222 Guest Bed 340 2545 690 117 110 STR 40 1181 322 54 51 Basement 705 6553 2402 300 383 Great Room 811 6752 12731 228 315 Bath 1 54 365 121 12 3 Hall 88 147 96 5 2 STR3 33 55 36 2 1 Clos 28 47 31 2 1 Bedroom 2 192 2799 6182 95 153 Entry 96 1660 2026 56 50 Main House 1302 11825 21223 400 525 Master 288 1384 960 114 113 Mudroom 112 926 907 77 107 Main Closet 75 126 79 10 9 M Bath 96 1194 1219 99 144 Master Zone 571 3629 3166 300 373 Unfinished 1208 0 0 0 0 (Unconditioned) 1208 0 0 0 0 Entire House 3786 22008 19598 1000 1281 W19 SO f " 2021-Nov-19 06:45:52:52 t . , . ,, ,.. Right-Suite®UriversaI202121.0.07RSU24598 Page 1 ACCAobs\Wrig tStarkSmithWrightBuldersLoadrp CaIc=MJ8 Frort Door faces: E Project SummaryJob: - - wrightsoftDate: August 10,2021 Entire House By: Pro'ect Information For: Starck&Smith,Wright Builders 238 Emerson Way,Northampton,Ma 01062 Notes: Desi•n Information Weather: Greenfield(Worcester Dd),MA,US Winter Design Conditions Summer Design Conditions Outside db -2 °F Outside db 85 °F Inside db 72 °F Inside db 68 °F Design TD 74 °F Design TD 17 °F Daily range M Relative humidity 50 % Moisture difference 42 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22008 Btuh Structure 19598 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfrn) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22008 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 17638 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 0 Structure 866 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft') 2578 2578 Equipment latent load 866 Btuh Volume(ft3) 23202 23202 Airchangs/hour 0.15 0.08 Equipment Total Load(Sen+Lat) 18504 Btuh Equiv.AVF(cfm) 58 31 Req.total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual airflow 0 cfrn Actual airflow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .,v,...i., „,soft' 2021-Nov-19 06:46:33 w ,- --,, Right-Siite®Urrversal2021 21.0.07 RSU24598 Page 1 ACCK ...obs\Wri ht Stark Smith\Wright Bulders Load.np Calc=MJ8 Front Door faces: E N /1 . Level 2 t t Room rSTR3 M Bath Master I Lea , x ' l�• .in• Closet Bath 1 Hall Clo Garage Entry Mud • Bedre m 2 C7 Job#: Scale:1 :114 Performed for: Page 1 Starck&Smith Righ0 ®Universal 2021 21. 238 Emerson Way 0721.0. RSU24598 Northampton,Ma 01062 2021-Nov-19 49 k Smith\Wright Builders Load.rup N Level 1 Bonus Room 71 1 STR /4Nd o/ uest Bed Unfinished -e"NV °1 Job#: Scale:1 :114 Performed for: Page 2 Starck&Smith Right-Suite®Universal 2021 238 Emerson Way 21.0.07 RSU24598 Northampton,Ma 01062 2021-Nov-19 49 ...k Smith\Wright Builders Load.rup Eligible for Federal Tax Credit. CERTIFIED" www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:204627055 Date: 10-07-2021 Model Status:Active AHRI Type: HRCU-A-CB(Mini-Split System:Heat Pump with Outdoor Unit-Air-Source,Ducted) Outdoor Unit Brand Name:Mitsubishi Electric Outdoor Unit Model Number:SUZ-KAl2NAHZ Indoor Type: Mini-Splits(Ducted) Indoor Model Number(s):SVZ-KP12NA Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(95F): 12000 EER(95F): 13.90 SEER: 19.00 High Heat(47F): 15000 Low Heat(17F):8900 HSPF: 10.20 Sold in?:USA,Canada (\(\ k0 4-(1/ t"Active"Model Status are those that an AHRI Certification Program Participant is currently p producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown alona with the previous(i.e.WASI rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part.be reproduced;copied;disseminated; entered into a computer database:or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on`Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, we make life better which is listed above,and the Certificate No.,which is listed at bottom right. I ©2021 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 132781082290583409 Eligible for Federal Tax Credit. ...I CERTIFIED° www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:204627019 Date: 10-07-2021 Model Status:Active AHRI Type: HRCU-A-CB(Mini-Split System: Heat Pump with Outdoor Unit-Air-Source,Ducted) Outdoor Unit Brand Name:Mitsubishi Electric Outdoor Unit Model Number:SUZ-KAO9NAHZ Indoor Type:Mini-Splits(Ducted) Indoor Model Number(s):SEZ-KDO9NA4 Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(95F):9000 EER(95F): 13.00 • SEER: 17.30 High Heat(47F): 12500 Low Heat(17F):8700 HSPF:9.80 Sold in?:USA,Canada in S ...4- ..- t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced."Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratinas that are accomoanied by WAS indicate an involuntary re-rate. The new published ratina is shown alona with the previous(i.e.WAS)ratino. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part.be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on`Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, we make life hewer which is listed above,and the Certificate No.,which is listed at bottom right. ©2021 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132781084868734584