Loading...
Bunk-PlansetGOVERNING CODESPARCELMAP PROJECT LOCATION SHEET INDEX ENGINEERED BY: CONTRACTOR: CONTRACTOR LIC #: PHONE: CONTACT NAME: PHONE: EMAIL: DESIGN BY: PHONE: HOME OWNER PROJECT LOCATION: PROJECT DRAFTER: LICENSE #: PHONE: ELECTRICAL UTILITY: AUTHORITY HAVINGJURISDICTION: BUILDING: CONTACT NAME:PHONE: LICENSE TYPE: PHONE: EMAIL: EMAIL: PHONE: SHEET SHEET TITLE EMAIL:AdvancedSolarSolutions2372MorseAve#912 Irvine, CA 92614 PHONE:559-321-7000EMAIL:info@advpermits.com PROJECT APN: GENERAL PROJECT & JURISDICTIONAL NOTES 1. UNAUTHORIZED USE OF THIS DRAWING SET WITHOUT EXPRESSEDWRITTEN PERMISSION FROM THE CONTRACTOR AND ADVANCED SOLAR SOLUTIONS IS A VIOLATION OF U.S. COPYRIGHT LAWS AND WILL BE SUBJECT TO CIVIL DAMAGES AND PROSECUTION. APPLICABLE BUILDING CODES: INTERNATIONAL BUILDING CODE INTERNATIONAL RESIDENTIAL CODE INTERNATIONAL FIRE CODE NATIONAL ELECTRIC CODE DESIGN CRITERIA BUILDING OCCUPANCY: RISK CATEGORY: EXPOSURE CATEGORY: SNOW LOAD: SNOW EXPOSURE: CONSTRUCTION TYPE: SCOPE OF WORK NUMBER PROPOSED SOLAR EQUIPMENT SITE / PROJECT DETAILS QTY. EQUIPMENT DESCRIPTION/MFG/MODEL MODULES INVERTER(S) RACKING STANCHIONS RSD DEVICE BATTERIES SYSTEM SIZE DC SYSTEM SIZE AC QTY. STRING/CKT. ELECT. SERVICE PROJECT TEAM LIST COPYRIGHT NOTICE 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH ALL OSHA REGULATIONS. 2. PENDING LOCAL JURISDICTIONAL REQUIREMENTS AND WHEN APPLICABLEALL ELECTRICAL ENCLOSURE DEAD FRONTS, COVERS, DOORS, ETC. SHALE BE OPEN AND ACCESSIBLE FOR INSPECTIONS. WHEN TRENCH AND ROOF INSPECTIONSARE REQUIRED WORK SHALL BE OPEN AND ACCESSIBLE FOR INSPECTOR. INSPECTION REQUIREMENTS 1. WHEN APPLICABLE A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL OR ANSI/UL 217 CERTIFIED TO NATIONAL FIRE ALARM AND SIGNALING CODE, NFPA 72 SHALL BE VERIFIED FUNCTIONAL OR INSTALLED IN ALL APPLICABLE CODE REQUIRED LOCATIONS. 2. ALL APPLICABLE EQUIPMENT TO BE UL LISTED OR LISTED BY OTHERJURISDICTIONAL AND UTILITY APPROVED ASSOCIATION OR NATIONALLY RECOGNIZED ORGANIZATION. 3. FULL SCOPE OF WORK SHALL COMPLY WITH ALL APPLICABLE CODES LISTED IN GOVERNING CODES SECTION, ALL MANUFACTURES' LISTINGS, INSTALLATION INSTRUCTIONS AND SPECIFICATIONS AND JURISDICTIONAL REQIREMENTS. JURISDICTIONAL & LISTING REQUIREMENTS 4. REVISED PLANS WILL BE REQUIRED TO BE RESUBMITTED TO THE LOCALJURISDICTION IF THE INSTALLED ARRAY AND ASSOCIATED EQUIPMENT DOES NOT MATCH THE APPROVED BUILDING PLANS. ADDITIONAL FEES MAY ALSOAPPLY. 5. THE PLACEMENT OF A UTILITY PV PRODUCTION METER SHALL BE PROVIDEDAND PLACED BY THE CONTRACTOR AS PER APPLICABLE UTILITY OR AHJREQUIREMENTS. MSP RATINGS COMBINER(S) AZIMUTH TILT ROOF COVERING RELEASEREVDATENAMECOVERSHEETAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH ℄ ⅊ ⅊⅊ ⅊DRIVEWAYMEADOW ST N/A VB 8.800 KW PV-001 COVER SHEET Bunk, Brian Jake Stocker 2015 National Grid 2015 05044630 2015 21134A(413) 584-8844 2020 Lilian Wanjiku(413) 584-8844 City of Northampton jstocker@valleysolar.solar 50507Civil(202) 874-3483swyssling@wysslingconsulting.com R-3 II Exposure C 40 Scott E. Wyssling 76 North Meadowbrook Dr (413) 584-8844 Alpine, UT 84004 jstocker@valleysolar.solar Bunk, Brian53 Meadow St, Northampton, MA 01062 ROOF MOUNTED PV (SOLAR) PROJECT GRID-TIED W/O BATTERY STORAGE 340 Riverside Dr Valley Solar Florence, MA 01062 Q-Cells Q.PEAK DUO BLK ML-G10+ 400Enphase IQ7PLUS-72-2-US (240V) SnapNrack Ultra Rail UR-40 Snapnrack 242-01220 L Foot INTEGRATED IN INV & OPT 2222 N/A 47N/A 0 1 (E) GPS COORDINATES (42.334724,-72.67616) 6.490 KW 2 120/240V - 1 30° 156° 117 Comp Shingle N-001 GENERAL NOTES PV-100R PV ARRAY LAYOUT S-100 RACKING LAYOUT S-200 SECTION ELEVATION S-201 ATTACHMENT DETAILS E-001 EQUIP. CALCULATIONMETER NUMBER:E-002 WIRE AND COND. CALCS E-003 THREE LINE DIAGRAM E-100 ELECTRICAL LAYOUT P-001 STANDARD PLACARDS P-002 DYNAMIC PLACARDS R-1xx EQUIP.CUT SHEETS Enphase X-IQ-AM1-240-3-ES 200A BUS/200A MAIN BREAKER BACK-FED BREAKER PV-001ASCE 7-10 WIND SPEED:Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMITSigned 12-7-21 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSGENERALNOTESGENERALNOTES:* PROPERACCESSANDWORKINGCLEARANCEAROUND EXISTINGANDPROPOSEDELECTRICALEQUIPMENTWILLBE PROVIDEDASPERSECTIONNEC110.26. PVSYSTEMCOMPONENTS;INCLUDINGBUTNOTLIMITED TO,MODULES,INVERTERSANDSOURCECIRCUIT COMBINERSAREIDENTIFIEDANDLISTEDFORUSEINPV SYSTEMSINCOMPLIANCEWITHNEC690.4AND690.6 ANDALLUL,IEC,IEEECLASSIFICATIONSAS REQUIREMENTS. RAPIDSHUTDOWNNOTES:* PVSYSTEMCIRCUITSINSTALLEDONORINBUILDIDNG SHALLINCLUDEARAPIDSHUTDOWNFUNCTIONTHAT CONTROLSSPECIFICPVCONDUCTORSINACCORDANCE WITH2020NEC690.12(A)-(D) EQUIPMENTLOCATIONS&ELECTRICAL NOTES:* JUNCTIONANDPULLBOXESAREPERMITTEDTOBE INSTALLEDUNDERPVMODULESINCOMPLIANCEWITH NEC690.34. ADDITIONALACDISCONNECT(S)SHALLBEPROVIDED WHERETHEINVERTERISNOTWITHINSIGHTOFTHEAC SERVICINGDISCONNECT.2020NEC690.15(A) ALLEQUIPMENTSHALLBEINSTALLEDACCESSIBLETO QUALIFIEDPERSONNELINCOMPLIANCEWITHNEC APPLICABLECODES. ALLCOMPONENTSARELISTEDFORTHEIRINTENDED PURPOSEANDRATEDFOROUTDOORUSAGEWHEN APPLICABLE. STRUCTURALANDINSTALLATION NOTES:* RACKINGSYSTEM&PVPANELSMOUNTEDONA ROOFTOPSHALLBELISTEDANDLABELEDINACCORDANCE WITHUL1703ANDSHALLBEINSTALLEDINACCORDANCE WITHTHEMANUFACTURERINSTALLATIONINSTRUCTIONS. ALLPVRACKINGATTACHMENTPOINTSSHALLNOTEXCEED THEPRE-ENGINEEREDMAXSPANSOUTLINEDBYTHE RACKINGMANUFACTURESENGINEEROFRECORD. GROUNDINGNOTES:* INUNGROUNDEDSYSTEMSONLYTHEDCCONDUCTORS AREUNGROUNDEDANDREQUIREANEQUIPMENT GROUNDINGCONDUCTOR.ALLMETALELECTRICAL EQUIPMENTANDSTRUCTURALCOMPONENTSBONDEDTO GROUND,INCOMPLIANCEWITHNEC250.134ANDNEC 250.136(A). PVEQUIPMENTINCLUDINGMODULEFRAMESANDOTHER METALPARTSSHALLBEGROUNDEDINCOMPLIANCE WITHNEC690.43ANDMINIMUMGROUND CONDUCTORSSIZEDINACCORDANCEWITHNECTABLE 250.122. CONDUCTIVEPARTSOFMODULEFRAMES,MODULE RACKING,ANDENCLOSURESSHALLBEGROUNDEDIN COMPLIANCEWITHNEC250.134ANDNEC250.136(A). UL2703APPROVEDMODULEANDRACKGROUNDING SHALLBEUSEDANDINSTALLEDPERMANUFACTURER'S INSTALLATIONMANUAL.IFUL2703APPROVED GROUNDINGISNOTUSED,MODULEGROUNDINGLUGS MUSTBEINSTALLEDATTHESPECIFIEDGROUNDINGLUG HOLESPERTHEMANUFACTURER'SINSTALLATION REQUIREMENTS. THEGROUNDINGCONNECTIONTOAMODULESHALLBE ARRANGEDSUCHTHATTHEREMOVALOFAMODULEDOES NOTINTERRUPTAGROUNDINGCONDUCTORTOANOTHER MODULE. THEGROUNDINGELECTRODESYSTEMCOMPLIESWITH NEC690.47ANDNEC250.50THROUGHNEC250.106. IFEXISTINGSYSTEMISINACCESSIBLEORINADEQUATE,A GROUNDINGELECTRODESYSTEMWILLBEPROVIDEDIN COMPLIANCEWITHNEC250,NEC690.47ANDAHJ. PVSYSTEMSSHALLBEPROVIDEDWITHDCGROUND- FAULTPROTECTION2020NEC690.41(B) INTERCONNECTION/POCNOTES:* ALLLOAD-SIDEINTERCONNECTIONSAREINCOMPLIANCE WITH2020NEC705.12(B) THETOTALRATINGOFALLOCPDINSOLARLOADCENTERS SHALLNOTEXCEEDTHERATEDAMPACITYOFTHEBUSBAR EXCLUDINGTHEOCPDPROTECTINGTHEBUSBARIN COMPLIANCEWITHNEC705.12(B)(2)(3)(c) ALLFEEDERTAP(LOADSIDE)INTERCONNECTIONSAREIN COMPLIANCEWITH2020NEC705.12(B)(2)(1) THEPVSYSTEMBACK-FEEDBREAKERSHALLBEINSTALLED ONTHEOPPOSITEENDOFTHEBUSBARANDITSHALL ALSOBESIZEDAPPROPRIATELYASPER2020NEC 705.12(B)(2)(3)(b) SUPPLYSIDETAPINTERCONNECTIONSAREIN COMPLIANCEWITHNEC705.12(A)WITHSERVICE ENTRANCECONDUCTORSINCOMPLIANCEWITHNEC 230.42 BACKFEEDINGBREAKERFORINVERTEROUTPUTISEXEMPT FROMADDITIONALFASTENING2020NEC705.12(B)(5) MICROINVERTERBRANCHCIRCUITSSHALLBECONNECTED TOASINGLEOCPDINACCORDANCEWITHTHEIR INSTALLATIONINSTRUCTIONSANDNEC690.9 DISCONNECTSANDOCPDNOTES:* ALLDISCONNECTINGSWITCHESWILLBECONFIGUREDSO THATALLENERGIZEDCONDUCTORSWHENDISCONNECTIS OPENSHALLBEONTHETERMINALSMARKED,“LINESIDE” (TYPICALLYTHEUPPERTERMINALS) ALLACDISCONNECTSSHALLBELABELED,LOCKABLE,OF VISIBLEBREAKTYPESWITCHWITHEXTERNALHANDLEAND ACCESSIBLETOQUALIFIEDUTILITYPERSONNEL. ACDISCONNECTSSHALLBEA“KNIFEBLADE”TYPE DISCONNECT.IFEXTERIOR,RATEDTONEMA3RORBETTER PERNEC110.28 ADDITIONALACDISCONNECTSSHALLBEPROVIDED WHERETHEINVERTERISNOTADJACENTTOTHEUTILITY ACDISCONNECT,ORNOTWIHTINSIGHTOFTHEUTILITYAC DISCONNECT.2020NEC690.15(A) BOTHPOSITIVEANDNEGATIVEPVCONDUCTORSREMAIN UNGROUNDED.THEREFORE,BOTHSHALLREMAINOPEN WHEREADISCONNECTISREQUIREDINCOMPLIANCEWITH 2020NEC690.15(D) ALLOCPDRATINGSANDTYPESSPECIFIEDSHALLBEIN COMPLIANCEWITHNEC690.8,690.9,705.12AND240. BOTHPOSITIVEANDNEGATIVEDCPVCONDUCTORSARE UNGROUNDED;BOTHREQUIREOVERCURRENT PROTECTIONINCOMPLIANCEWITHNEC690.9 ARCFAULT(AFCI)DCCIRCUITPROTECTIONISREQUIRED FORALLPVSYSTEMSONORPENETRATINGABUILDING WITHAMAXIMUMSYSTEMVOLTAGEOF80VOLTSOR GREATER.ALLDCPVCIRCUITSINSTALLEDINORON BUILDINGSWILLBEARC-FAULTCIRCUITPROTECTEDIN COMPLIANCEWITHNEC690.11,UL1699BANDSHALLBE LISTEDANDLABELEDINACCORDANCEWITHUL1699(B). WIRING&CONDUITNOTES:* ALLCONDUITANDCONDUCTORSSHALLBEAPPROVED FORTHEIRINTENDEDPURPOSEINCLUDINGWET LOCATIONSANDEXPOSEDTOSUNLIGHT.CONDUITAND CONDUCTORSIZESPECIFICATIONSAREBASEDONTHE MINIMUMCODEREQUIREMENTSANDARENOTLIMITED TOUPSIZING. ALLCONDUCTORSSHALLBESIZEDINCOMPLIANCEWITH NEC690.8,NEC690.7. ALLCONDUCTORSSHALLBEDERATEDASAPPLICABLETO THEIRRESPECTIVEENVIRONMENTINCLUDINGDIRECT SUNLIGHTINACCORDANCEWITH2020NEC 310.15(B)(3)(4)(c) EXPOSEDUNGROUNDEDDCPVSOURCEANDOUTPUT CIRCUITSSHALLUSECONDUCTORSLISTEDANDIDENTIFIED ASPHOTOVOLTAIC(PV)WIREINCOMPLIANCE2020NEC 690.31(C)(1).PVMODULESWIRELEADSSHALLBELISTED FORUSEWITHUNGROUNDEDSYSTEMSINCOMPLIANCE WITH2020NEC690.4(B) PVWIREBLACKWIREMAYBEFIELD-MARKEDWHITEIN COMPLIANCEWITHNEC200.6(A)(6). PVMODULECONDUCTORSLOCATEDUNDERARRAYSWILL BESECUREDINAWORKMANLIKEMANNERIN COMPLIANCEWITHNEC110.12. WATERPROOFING:* ALLNEWROOFTOPPENETRATIONSSHALLBESEALEDAND MADEWEATHERTIGHTWITHAPPROVEDCHEMICAL SEALANTANDFLASHINGSWHEREREQUIREDPERCODE ANDGENERALBUILDINGANDROOFINGWORKMANSHIP STANDARDSBYALICENSEDCONTRACTOR. ALLEXTERIORELECTRICALEQUIPMENT,SHALLBENEMA 3RORBETTERRATED.ALLEXTERIORCONDUITAND CONNECTORSSHALLBERATEDFORWETLOCATIONS. *ALLNOTESAREASAPPLICABLETOTHISPROJECT. DISREGARDANYNOTESTHATDONOTAPPLYTOTHIS PROJECT.N-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMITSigned 12-7-21 SECTION 1 SECTION 2 RA RA PV SITE LAYOUT LEGEND *EXISTING DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PVARRAYLAYOUTSQUARE FOOTAGE CALCULATIONS ROOFREFERENCE SQUARE FOOTAGE TOTAL PERCENTAGE AZIMUTH ANDTILTTABLE SECTION #AZIMUTH ROOFPITCH/TILT EXISTINGROOF SECTION 1 ROOF ACCESS POINT SITEACCESS GATE ACCESS SECTION 1 PVARRAY TAGSECTION#MODULE GROUP RA SA GA NOTE: ALL ELECTRICAL LAYOUT DETAILS ON SHEET E-100 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANS2015 IFC ROOF ACCESS REQUIREMENTS THIS SHEET REPRESENTS THE SOLAR MODULE LAYOUT ON ROOFTOP. SHADED DASHED LINE NEAR PERIMETER OF STRUCTURE EXTERIOR IS PHOTOVOLTAIC MODULES ARE SCALED IN PLAN VIEW AND MAY NOTBE AN ACCURATELY SCALED REPRESENTATION OF THE ACTUAL SCALE AND GEOMETRY OF THE PHOTOVOLTAIC MODULE. ACTUAL PHOTO- VOLTAIC MODULE DIMENSIONS ARE ON SHEET E-001 FOR THE PURPOSE OF CLARITY, ALL ELECTRICAL LAYOUT DETAILS ARE LOCATED ON SHEET E-100. A. B. C. AN APPROXIMATE REPRESENTATION OF THE EXTERIOR WALL LOCATION NORTH PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER SCALE: 1/8” = 1’0” @ SHEET SIZE A3 1717 SECTION-1 253 27.02% 156 30°SECTION-1 156 30°SECTION-2 211SECTION-2 QTY 22 Q-Cells Q.PEAK DUO BLK ML-G10+ 400 MODULES, QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV-100RValley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMITSigned 12-7-21 12'-4''12'-4''20'-7" 24'-0" SHEET NOTES *EXISTING ROOF DIMENSIONS ARE APPROX.CONFIRM ALL DIMENSIONS SHOWN PV RACKING LEGEND RACKINGLAYOUTRACKING BILL OF MATERIALS (BOM) COMPONENT QTY MODEL LENGTH PV RAIL 1 PVRAILSPLICE 1 PV RAIL 2 PVRAILSPLICE 2 RAILTOROOFATTACHMENT EXISTING ROOF CONSTRUCTION COMPONENT TYPE ROOF STRUCTURALCONSTRUCTION ROOFINGCOVERING RACKING MAXPSF ROOF RACKING RAIL SPLICE ROOF RACKINGSTANCHION W/RETRO FIT FLASHING *DETAILSINTOP VIEW SECTION 1 PV ARRAY TAGSECTION#MODULEGROUP B.￿￿￿￿￿ANCHOR SPACING SHOWNINDETAIL.UNLESSNOTEDOTHERWISE PERRACKINGMANUFACTURERCERTIFIEDENGINEEREDPRODUCTANDLOCALREQUIREMENTS.SEE"TABLE OF DIMENSIONS"EACHSECTION DETAILEDFORHORIZONTALANCHORSPACING. C.SEESHEET S-200FOR SPECIFIC RACKING COMPONENTMANUFACTURERS. FRAMINGINFO ROOFRACKINGRAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH SCALE: 1/8” = 1’0” @ SHEET SIZE A3 Pre-Eng Roof Trusses 24" O.C. 2"x6" @ 24" MAX OC Comp Shingle 2.91 PSF QTY 22 Q-Cells Q.PEAK DUO BLK ML-G10+ 400 MODULES, QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER S-100A. FOR MANUFACTURED PLATED WOOD TRUSSES AT SLOPES OF FLAT TO 6:12, THE HORIZONTAL ANCHOR SPACING SHALL NOT EXCEED 4’-0” AND ANCHORS IN ADJACENT ROWS SHALL BE STAGGERED. UNLESS NOTED OTHERWISE PER RACKING MANUFACTURER CERTIFIED ENGINEERED PRODUCT AND LOCAL REQUIREMENTS.Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMITSigned 12-7-21 SHEET NOTES PV RACKING LEGEND TABLE OF COMPONENTS COMPONENT MODEL 1 PV RAILTYPE 1 2 PV RAILSPLICE TYPE 1 3 PV RAILTYPE 2 4 PV RAILSPLICE TYPE2 5 STANCHION 6 FLASHING 7 MIDCLAMP 8 END CLAMP 21SCALE:NTS 3 4 A.THESENOTES APPLYTO PRE-ENGINEERED PLATED TRUSSES. B.THEROOFSTRUCTURE CONFORMED TO BUILDING CODEREQUIREMENTSATTHETIMEITWASBUILT. C.STRANDBOARD OR PLYWOOD.1X SKIP SHEATHINGISACCEPTABLE. D.THESOLAR ARRAY DISPLACES ROOF LIVELOADS(TEMPORARYCONSTRUCTIONLOADS)THAT THE ROOF WAS ORIGINALLY DESIGNEDTO CARRY. E.IF THE ROOF COVERING ISSHINGLES;IT SHALLHAVE NOMORETHANTWOLAYERS.(SHOWN) F.IF ROOF COVERING IS TILE;ITS ASINGLELAYER.ALLTILES ONPLANEOFPVCOMPONENTSARESECURE. (NOT SHOWNINDETAIL) G.THEROOFSTRUCTURE IS STRUCTURALLYSOUND,WITHOUTSIGNSOFALTERATIONSORSIGNIFICANTSTRUCTURALDETERIORATION OR SAGGING. H.THEPV MODULESAREPARALLEL WITHTHEROOFSURFACE. I.AND THE ROOF SURFACE.(SEE TABLEOF DIMENSIONS "H1") J.UPSLOPE ANCHOR SPACING MAYVARYFROMLISTEDTABLES.STANCHIONS CAN BE PLACEDNOCLOSER THAN 24"O.C. K. # SCALE:NTS SCALE:NTSSCALE:NTS SECTIONELEVATIONSTABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PVMODULE HGT.ABOVE ROOF RISE ROOFPITCH OH1 OVERHANGINTHIS AREA UPSLOPEANCHOR SPACING D1 RAILOVERHANG D3 STANCHION O.C. D2 STANCHIONO.C.D4 MIN./MAX.STANCHION O.C. TABLE OF DIMENSIONS DIM COMPONENT DIMENSIONS DIM COMPONENT DIMENSIONS H1 PVMODULE HGT.ABOVEROOF RISE ROOF PITCH OH1 OVERHANG IN THISAREA UPSLOPE ANCHOR SPACING D1 RAILOVERHANG D3 STANCHION O.C. D2 STANCHION O.C.D4 MIN./MAX.STANCHION O.C. EXISTING ROOF CONSTRUCTION COMPONENT TYPE MEANROOFHGTMAX ROOFINGCOVERING *DETAILS IN SECTIONORSIDE VIEW ROOFRACKING RAILSPLICE ROOFRACKINGSTANCHIONW/RETRO FIT FLASHING SECTION 1 PVARRAYTAGSECTION#MODULE GROUP PERRAIL MANUFACTURER MAX RAFTERSPAN MAXRAFTER SPAN L. DETAILS SHOWN AREA REPRESENTATION OFEXISTINGROOFCONDITIONS.ACTUALFIELD CONDITIONS MAYVARY.DETAILSARE SHOWN FOR DIAGRAMUSE ONLY.REFERTO TABLES FORDESIGNCRITERIA. ALL PLUMBING ANDROOFVENTS SHALL NOTBEOBSTRUCTEDBYPVMODULESANDEQUIPMENT. M. ROOF RACKING RAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANS1 5 6 7 RISE 12 PRE-ENGINEEREDFRAMING@APPROX.24"O.C. 2 OH1 PV1 D1H1 D3 D2 D2 *IF BLOCKINGREQUIRED32 S-201 1 S-201 **COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENTFOR STANDING SEAMMETAL ROOFAPPLIES. D3 12RISE 5 6 8 1 7 3 PV1 D1H1 OH1 D2 D1 D3 D2 *IF BLOCKINGREQUIRED32 S-201 1 S-201 D224"MINWHENNOTSTAGGERED.TYP PRE-ENGINEEREDFRAMING@APPROX.24"O.C. **COMP SHINGLE ROOF IN EXAMPLE.SAME ATTACHMENTFOR STANDING SEAMMETAL ROOFAPPLIES. PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 2'-0"TYP.4'-0"MAX (E)PRE-ENG.TRUSS @ ASSUMED24"O.C.TYPICAL 25' Comp Shingle MANUF TRUSS / TRUSS - PORTRAIT MANUF TRUSS / TRUSS - LANDSCAPE STANCHION DETAIL STANCHION SPACING DETAIL 30°3" - 6" TYP 18.5" 37" 37.25" Ultra Rail UR-40 242-01220 L Foot L-Foot Flashing 30°3" - 6" TYP 10.27" 20.55" 20.8" NOT USED ENGINEERED TRUSS ENGINEERED TRUSS S-200PER RAIL MANUFACTURER PER RAIL MANUFACTURER PER RAIL MANUFACTURER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMITSigned 12-7-21 SHEET NOTES PV RACKING LEGEND *DETAILS INSECTION OR SIDEVIEW 1.(1) ENGINEERING. 2.ADHERETO RACKING MANUFACTURERS INSTALLATIONINSTRUCTIONS PERTAINING TOCANTILEVER. 21SCALE:NTS 3 4 SCALE:NTS SCALE:NTSSCALE:NTS ATTACHMENTDETAILSROOFRACKING RAILSPLICE ROOFRACKINGSTANCHION W/RETROFITFLASHING SECTION 1 PV ARRAYTAGSECTION#MODULE GROUP ROOFRACKINGRAIL RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSALLANCHORLAGSTOBEMINIMUM2-1/2"EMBEDMENTINTOFRAMINGMEMBERS (E)ROOFSHEATHING /DECKING (E)FRAMINGMEMBER L-FOOT PVMODULE, BYOTHERS MODULEEND CLAMP SNAPNRACK ULTRARAIL L-FOOTFLASHING5/16”-18X2-1/4” SSHCSBOLT 1/3"OF TOTAL SPAN MAX 2/3"OF TOTAL SPAN MAX RAIL MANUFACTURERRAILSPLICEKITSEE"S-100 /TABLE OF COMPONENTS" SPACING VARIES STAGGER STANCHIONS WHERE POSSIBLE.SEE SHEET "S-100"FOR:HORIZONTAL ANCHOR SPAN SPACING. (E)FRAMINGTYPICAL *MODULES SHOWNPORTRAIT IN EXAMPLE DCAND/OR 1/3CANT.MAX COMPONENT +2"FROM SIDEOFMODULE 2" ROOF TOPCONDUIT EXTENSION OF RAIL RAIL OR STRUTCONNECTIONSTOMEETWEIGHTREQ.OF EQUIPMENT DCB *MODULES SHOWNPORTRAIT IN EXAMPLE**RAILING SHOWINGINVERTICALINEXAMPLE STANCHION ATTACHMENT DETAIL WITH FLASHING RAIL SPLICE DETAIL - HORIZONTAL RAIL RAIL EXTENSION DETAIL NOT USED S-201Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMITSigned 12-7-21 PV SYSTEM MAXIMUM VOLTAGE (MODULE VocMAX) DATA SOURCE SOLARABCS.ORG/ABOUT/PUBLICATIONS/REPORTS/EXPEDITED-PERMIT/MAP/ EXTREME MIN. STCTEMPERATURE CORRECTEDTEMPERATURE MFR.PMAX TEMPCOEFFICIENT[-0.#%/C]*100 FORMULA CORRECTEDTEMP.COEFFICIENT MODULE Voc[VDC] TEMPERATURECORRECTEDOPENCIRCUITVOLTAGE-=*+=*= PV MODULE #1 SPECIFICATIONS MANUFACTURER MODEL NUMBER WEIGHT Ibs DIMENSIONS L"xW"xD"/THICK PEAKPOWER @ STC (Pmax)WATTS Voc(OPEN-CIRCUIT VOLTAGE)VOLTSDC Vmp (MAX-POWER VOLTAGE)VOLTS DC isc (SHORT-CIRCUITCURRENT)AMPS imp(SHORT-CIRCUIT POWER)AMPS MFR.VocTEMPCOEFFICIENT %/K MAXSERIES FUSE RATING AMPS TEMP.CORRECTEDVoc VOLTS DC AC COMBINER (SOLAR LOAD CENTER) MANUFACTURER MODEL NUMBER RATED OPERATIONAL VOLTAGE VOLTS RATEDCURRENT AMPS NUMBER OFPOLES P NEMA RATING MAINBREAKERSIZE TOTALINPUTCURRENT AMPS NUMBER OF BRANCHCIRCUITS AMPS CIRCUITS AC SUB-PANEL #1 (IF APPL.) NEW OR EXISTING MAKE/MODEL TYPE OFPANEL NUMBEROF POLES P NEMARATING BUSS BARRATING AMPS SUB-PANEL MAIN BREAKER AMPS MAINSERVICE PANEL P.O.C.BREAKER AMPS SUM OFEXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLARCURRENT AMPS PVBACKFEED BREAKER #1 AMPS (Imax) AMPS (Imax) MAIN SERVICE PANEL (IF APPL.) NEW OR EXISTING ELECTRICAL SERVICE BUSSBAR RATED CURRENT AMPS MAIN BREAKER RATED CURRENT AMPS AMPS AMPS AMPS (Imax) AMPS(Imax) AC SUB-PANEL #2 (IF APPL.) NEW OR EXISTING MAKE/MODEL TYPE OFPANEL NUMBEROF POLES P NEMARATING BUSS BARRATING AMPS SUB-PANEL MAIN BREAKER AMPS MAINSERVICE PANEL P.O.C.BREAKER AMPS SUM OFEXISTING CIRCUIT BREAKERS AMPS MAX ALLOWABLE SOLARCURRENT AMPS AMPS (Imax) AMPS (Imax) MICRO INVERTER #1 SPECIFICATIONS MANUFACTURER MODELNUMBER NOMINAL POWER RATING WATT AC WEIGHT Ibs.DC INPUT Max PV POWER @MODULE STC WATTS MaxINPUT DC VOLTAGE VOLTS DC MaxINPUT CURRENT AMPS MODULES PER MICROINVERTER QTYACOUTPUT NOMINALVOLTAGE OUTPUT VOLTS AC MAX OVERCURRENTPROTECTION(OCPD)AMPS MAX.OUTPUT CURRENT AMPS -MAX AC DISCONNECT #1 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECTDEVICE TYPE RATEDOPERATIONALVOLTAGE VOLTS RATED CURRENT AMPS NUMBER OF POLES P NEMA RATING FUSERATING AMPS TOTALINPUT CURRENT QUANTITY AC DISCO.(S) AC DISCONNECT #2 MANUFACTURER (IF APPL.) AMPS MODEL NUMBER DISCONNECTDEVICE TYPE RATEDOPERATIONALVOLTAGE VOLTS RATED CURRENT AMPS NUMBER OFPOLES P NEMARATING FUSERATING AMPS TOTALINPUT CURRENT QUANTITY AC DISCO.(S) PVBACKFEED BREAKER#2 PV BACKFEEDBREAKER #1 PV BACKFEEDBREAKER#2 AMPS (Imax) SUMOF EXISTING CIRCUITBREAKERS MAX ALLOWABLE SOLARCURRENT100% MAX ALLOWABLE SOLAR CURRENT120% PVBACKFEED BREAKER #1 PV BACKFEEDBREAKER #2 ALT.ENERGY BACKFEEDBREAKER (IF APPL.)AMPS(Imax)RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CALCULATIONSQ-CellsQ.PEAK DUO BLK ML-G10+ 40048.574.0 x 41.1 x 1.2640045.3037.1311.1410.77-0.2720.0 EnphaseIQ7PLUS-72-2-US (240V)2902.38 2906015.01 240201.21 EnphaseX-IQ-AM1-240-3-ES24012523RN/A26.622 EatonDG222URB NON-FUSIBLE DISCONNECT120/2406023RN/A 26.62 EXISTING120/240V Single Phase200200 04040 -20 25 -45 -0.27%0.12 1 1.12 45.30 50.74 50.74 1 E-001Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT ≤ ≤ DC WIRE AND CONDUIT SIZING CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUITORIGIN CIRCUIT CONDUCTORSPECIFICATIONS REQUIRED CONDUCTOR AMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER310.16 MAXCURRENT690.8 (A)(1) CONT.OPERATION690.8(B)(1) REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF(in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT.TEMP. AMPACITYCORRECTION310.15(B)(2)(a) #OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY TEMP.DERATING CONDUITFILLDERATINGXXX=XX=CORRECTEDAMPACITY REQUIREDAMPACITY CORRECTEDAMPACITY DC1 XXX=XX= 1.ANYCONDUCTOR LENGTHUNDER 50'DOESN'T REQUIRE VOLTAGE DROP CALCULATIONS DEEMED QUESTIONABLE TO PREVENT ISSUES RELATED TO USING CONDUCTORSTHAT ARE IMPROPERLY SIZED.3. PV DC WIRING AC WIRING 2.BECAUSEWE ARE UNABLETODETERMINE THE EXACT PATHTHE INSTALLER WILLRUN CONDUCTORS;WORSTCASESCENARIOS,ROUNDING UPSIZES OFCONDUCTORS THAT AREEQUIPMENT GROUNDGREENOR BARE,OR GREEN/YELLOWEQUIPMENT GROUND GREEN OR BARE,OR GREEN/YELLOW TYPICALLYNEGATIVEWHITEOR GRAY(NEUTRAL)WIRING METHODS IN THESECALCULATIONS DON'T EXCEED 1000 VOLTSGROUNDED CONDUCTOR.GROUNDED CONDUCTORWHITEOR GRAY UNGROUNDEDCONDUCTOR(S).TYPICALLYPOSITIVE ANYCOLOR OTHER THAN GREENORWHITE/GRAY UNGROUNDED L1AND L2 ANYCOLOR OTHERTHANGREEN OR WHITE/GRAYALLOWED. CONVENTION IS RED FORGROUNDED SYSTEMSCONDUCTOR(S)HOT:CONVENTIONISL1BLACK RED (+)AND BLACK(-)FOR UNGROUNDED SYSTEMSCONVENTIONIS L2 RED WIRE AND CONDUCTOR NOTES WHEN LESSTHAN10'-0"OR 10%OF THE CIRCUIT LENGTH;THE LESSERAMPACITY MAYBEUSED.USEDBEYONDTHE POINT OFTRANSITION,ADISTANCE EQUAL TO 10'-0"(3 METERS)OR 10%OFTHECIRCUIT LENGTHFIGURED AT THE HIGHER AMPACITY,WHICHEVER IS LESS.4.CEC/NEC310.15(A)(2)(AS APPLICABLE)WHERE TWO DIFFERENTAMPACITIESAPPLY TOADJACENT PORTIONSOF A CIRCUIT,THE HIGHERAMPACITYSHALL BEPERMITTEDTO BE AC WIRE AND CONDUIT FILL DERATE CHART [SEE SHEET E-003 FOR THREE LINE DIAGRAM] TAG CIRCUIT ORIGIN CIRCUITDESTINATION CONDUCTORSPECIFICATIONS REQUIRED CONDUCTORAMPACITY CONDUCTOR TEMPERATURE DERATING CONDUIT FILLDERATING CORRECTED AMPACITY CALCULATION AMPACITY CHECK TEMPRATING TRADESIZE AMPACITYPER 310.16 CONT.OPERATION690.8 (B)(1)X =REQUIREDAMPACITY CIRCUITENVIRONMENT AMBIENTTEMP. HGT.ABOVEROOF(in) TEMP.ADDER PER310.15(B)(2)(c) OPERAT. AMPACITYCORRECTION310.15(B)(2)(a) #OFUNGRND.COND. AMPACITYCORRECTION310.15(B)(3)(a) COND.AMPACITY X TEMP.DERATING X CONDUITFILLDERATING =CORRECTEDAMPACITY REQUIREDAMPACITY CORRECTEDAMPACITY AC1 X =X X = AC2 X =X X = AC3 X =X X = AC4 X =X X = AC5 X =X X = AC6 X =X X = AC7 X =X X = AC8 X =X X = AC9 X =X X = AC10 X =X X = #OFCOMBINEDPARALLELCIRCUITS QTY INPARALLEL&MATERIAL QTYINPARALLEL&MATERIAL DESTINATION MAX INV.OUTPUTCURRENT(AMPS)ORCOMPONENT(AMPS) lsc(AMPS)ORCOMPONENT(AMPS) ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤ ≤RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSWIREANDCOND.CALCS.PV MODULE INVERTER (1) CU 90 #12 AWG 30 11.14 1 1.25 1.25 17.4 ROOFTOP 35 >7/8"0 35 0.96 2 N/A 30 0.96 1.0 28.8 17.4 28.8 INVERTER JUNCTION BOX (1) CU 75 #12 AWG 25 1.25 13.31 16.6 ROOFTOP 35 >7/8"0 35 0.94 4 N/A 25 0.94 1.0 23.5 16.6 23.5 AC COMBINER/LOAD CENTER (1) CU 75 #10 AWG 35 1.25 13.31 16.6 ATTIC 35 >7/8"0 35 4 .80 350.94 0.94 .80 26.3 16.6 26.3 AC DISCONNECT (1) CU 75 #8 AWG 50 1.25 26.62 33.3 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 33.3 47.0 PRODUCTION METER (1) CU 75 #8 AWG 50 1.25 26.62 33.3 INT/EXT WALL 35 N/A 0 35 0.94 3 1.0 50 0.94 1.0 47.0 33.3 47.0 EXISTING SERVICE PANEL (1) CU #8 AWG 50 1.25 26.62 33.3 INT/EXT WALL 35 N/A 0 JUNCTION BOX AC COMBINER/LOAD CENTER AC DISCONNECT PRODUCTION METER 75 35 0.94 3 1.0 50 0.94 1.0 47.0 33.3 47.0 E-002WIRE COLOR CODING (2020) NEC SECTIONS 250.119 & 200.6 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT LEGEND THREELINEDIAGRAMEQUIPMENT TABLE QTY COMPONENT 1 PVMODULES 2 MICRO INVERTER 3 AC COMBINERBOX 4 JUNCTIONBOX 5 NEW SOLAR LOAD CENTER 9 AC DISCONNECT (FUSIBLE) 7 PROD/GENERATION METER 8 SUB PANEL 10 11 12 EXISTING UTILITY METER TAG BRANCH MODULE QTY OCPD BACK-FEEDSOLARBREAKER: TAG QTY*SIZE TYPE DC1 AC1 AC2 AC3 AC4 AC5 GROUND SIZE TYPE AC6 AC7 AC9 AC10 AC8 6 AC DISCONNECT AT GROUND LEVEL *INCLUDESGROUND&CURRENT CARRYING CONDUCTORS • 13 BATTERY 14 NOTE:EQUIP TAGS MAY NOT BEINSEQUENTIAL ORDER,N/AUSED DC CONDUCTOR TAG AC CONDUCTOR TAG EQUIPMENT TAG AC# DC# GROUND CONDUCTOR TAGGND ELECTRICAL NOTES SEE SHEET E-001 FOR ADDITIONAL ELECTRICAL SPECIFICATIONS CONDUCTOR TABLE CONDUIT TABLE •INTEGRATEDMICRO INVERTERS(AC MODULES)MUSTBE CERTIFIEDUL1742ANDUL1703COMPLIANT.ASEITHERINDIVIDUALCOMPONENTSOR AC MODULEASSEMBLY.THEYMUSTALSO BELABELED "UTILITYINTERACTIVE"CONFORMINGTO IEEE1547TESTING. •PV MODULESTHATHAVE INVERTERS ATTACHEDWITHOUT AN ACMODULEEVALUATIONBYANRTLMAYVIOLATETHEORIGINALLISTING OFTHE PVMODULE ANDVOID THE WARRANTY OFTHE MODULE. •VERIFY MODULEIS COMPATIBLEWITH MICROINVERTERMANUFACTURERANDMODEL. •ARTICLE CEC/NEC 690 STILL APPLIES.THE INSTALLERWILLNEEDTOCONSIDERREQUIREMENTSSUCHAS:DCGROUNDFAULTDETECTIONANDINTERRUPT,DCCABLE MANAGEMENT,DCDISCONNECTING MEANSAND DC GROUNDING ASWELL AS THE ACEQUIPMENTGROUNDING CONDUCTOR TO THEINVERTER. BACKFEEDING.NECINFORMATIONAL NOTE:FUSED DISCONNECTS,UNLESSOTHERWISEMARKED,ARE SUITABLEFORBACKFEEDING. •690.13(F)(2)DEVICES MARKED WITH "LINE” AND “LOAD” SHALL NOTBE PERMITTED FOR BACKFEED OR REVERSE CURRENT •705.12(B)(5)CIRCUITBREAKERSBACKFEEDFROM UTILITYINTERACTIVEINVERTERS(ANTI-ISLANDING,UL1741CERTIFIED) •ALL OVERCURRENT PROTECTIONDEVICES (OCPDs)MUST BE RATEDFOR600VOLTSONTHEDC/PVPOWERSIDE OFTHEINVERTER. •ALL CONDUIT ANDCONDUIT CONNECTIONS SHALLBE RATED FORWETANDDAMPLOCATIONSWHENAPPLICABLE. INTERCONNECTIONNOTES: •705.12(B)(4)CIRCUITBREAKERSMUST BE SUITABLE FOR RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSINVERTER NAMEPLATE RATING 295W/240V MODULE NAMEPLATE RATING 400W (-)(+) (-)(+) ACDC ACDC 2 2 11MODULES 1 1 11MODULES (+) (+) 2 2 AC DC(-) (-)DC AC 1 1 DC1 EGC AC1 G G L1 L1 L1 L1 L2 L2 L2 L2 AC2 4 L2 L1 G BUSRATING 3 L2L1 G N ENVOY-IQFORMONITORING GEC N 125A 10A 20A 20A (2)STRINGS (L1/L2 SHOWN)OF (11)MODULES N G L2 L1PV N G L2 L1 7 AC4AC3 READILY ACCESSIBLE OPEN BLADE AC SYSTEM DISCONNECT(UTILITY ONLY)VISIBLE FROM APPROACH TORESIDENCE60A240VLOCATEDEXTERIORONWALLNEARMETERNEMA3R L2 L1 L2 L1 GG NN 6 AC5 M 12 G N BUSRATING 11 MAIN C/BRATING GEC 200A 200A LOCATED EXTERIORSOLARGENERATION(LOAD) BOTTOMLUGS TO TOP LUGSTO UTILITY (LINE) CUSTOMER OWNED GENERATION METER EGC NOTE: CONDUCTORS AC3, AC4 & AC5 MAY BE THWN-2 OR SER CABLE 40A 22 Q-Cells Q.PEAK DUO BLK ML-G10+ 400 Enphase IQ7PLUS-72-2-US (240V) Soladeck RSTC 0799-5B Eaton DG222URB CUSTOMER OWNED GENERATION METER 1 11 20A 2 11 20A 120/240V - 1 #12 AWG PV Wire Open Air 40A NO CENTER-FED MAIN BREAKER. PANEL CONFIGURED PER NEC 705.12(B)(2)(3)(b) 22 1 2 0 1 1 0 0 1 1 2 #6 AWG N/A 5 #12 AWG TRUNK CBL #6 AWG N/A Open Air 5 #10 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT 4 #8 AWG THWN-2 #8 AWG 3/4 inch EMT Enphase X-IQ-AM1-240-3-ES E-003EXISTING MAIN SERVICE PANEL 200A BUS/200A MB 0 Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT SPMACPACCJB JB ELECTRICAL SYMBOL LEGEND SECTION 1 PV ARRAY TAGSECTION#MODULEGROUP ACDISCONNECT PERFORMANCEMETER UTILITY METER JUNCTION BOX AC P M ELECTRICALLAYOUTEQUIPMENT GROUNDING 1.METAL PVMODULE FRAMES NEED TO BE CONNECTEDTOTHEEGC(EQUIPMENTGROUNDINGCONDUCTOR). 1.1.WEEBS MAY BE USED IN LIEUOF MODULE GROUND CLAMPSORLUGS,WITH APPROVAL OFAHJ AND RACKINGMFG.WEEBSAREONETIMEUSEONLY.SEE "we-llc.com"FORRACKINGSPECIFICWEEB,INSTALLINSTRUCTIONS,AND UL 2703 CERT. 1.2.FOR "LAY-IN"LUG MODULE GROUNDING;CORRECTHARDWAREOFPROPERMETALMATERIALTOAVOIDCORROSIONMUSTBEUSED.TYPICALLYDIRECT BURIALRATED,TINNED,OR STAINLESS STEEL.GROUNDINGLUGSMUSTBEATTACHEDATMARKEDLOCATIONONEACHMODULE. 2.THE EGC(EQUIPMENT GROUNDING CONDUCTOR)IS USED TOBONDALLNON-CURRENTCARRYING CONDUCTORS AND EXPOSEDMETALPARTSTHATMIGHTCOMEINTOCONTACTWITHCURRENT-CARRYING CONDUCTORS,INCLUDING THE FOLLOWING: 2.1.PV MODULES FRAMES,ARRAY MOUNTING RACKING;THEMETALCHASSISOFEQUIPMENTSUCHASINVERTERS,DISCONNECTS,METERS,JUNCTION BOXESANDCOMBINERBOXES;AND METALCONDUIT HOLDING CIRCUITS >250VOLTSTOGROUNDPERNEC250.97 3.THE GEC (GROUNDINGELECTRODECONDUCTOR)ISTHECONDUCTORUSEDTOCONNECTTHEGEORGESYSTEMTOTHESYSTEMGC,TO THE EGC,OR TO BOTH. 4.THE GE(GROUNDINGELECTRODE)ISA CONDUCTING OBJECT,OFTEN A ROD,RING,OR PLATEESTABLISHINGA DIRECTCONNECTIONTOEARTH.THE ACSYSTEM GROUND IS EXISTING,USUALLY AT THE EXISTING MAIN PANELAND/ORUTILITY METER.THE GROUNDCANONLYOCCUR IN ONE PLACE ANDMUSTNOTBEDUPLICATEDINSUB-PANELS ORANYWHEREELSE ON ACSIDE. SERVICEPANELSP AUTO TRANSFORMERATF SOLARLOAD CENTER BATTERY SLC AC COMBINERACC BATT CLP CRITICAL LOADS PANEL JB XFMR TRANSFORMER SUB-PANELSUB ATS AUTO TRANSFERSWITCH CB CIRCUITBREAKER DISCONNECT RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNORTH SCALE: 1/8” = 1’0” @ SHEET SIZE A3QTY 22 Q-Cells Q.PEAK DUO BLK ML-G10+ 400 MODULES, QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER PV AC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITH EXTERNAL HANDLE VISIBLE, LOCKABLE & LABELED WITHIN 10 FEET OF THE METER E-100Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT SHEET NOTES1SCALE:1/2"=1'-0"CONDUIT,RACEWAY,J-BOX,AND PULL BOXES 2 3 5 6 7 SCALE:1/4"=1'-0"8 9 4 1.PLACE ON CONDUITAND/OR RACE WAYSEVERY10'(60"),12"FROMBENDS,12"ABOVEAND BELOW PENETRATIONS. 2.CODE REFERENCE:NEC 690.31(G)(3)3.MINIMUMOF 11/8"x 53/4" 4.FONT:3/8"AND .8WIDTHFACTOR. 5.REFLECTIVEWHITELETTERSONA RED BACKGROUND. J-BOX,DC COMBINER,AND DC DISCONNECT SCALE:1/4"=1'-0" NON-LOAD BREAK DC COMBINER /J-BOX 1.PLACEDONDC DISCONNECT(S)ANDON ANYEQUIPMENT THAT STAYS ENERGIZED IN THE OFFPOSITION FROMTHEPVSUPPLY. 2.CODEREFERENCE:NEC 690.13(B) 3.MINIMUM OF 3 1/2"x 10" 4.FONT:3/8" INVERTER(S) SCALE:1/2"=1'-0" 1.A RAPIDSHUTDOWN SWITCH SHALL HAVEA LABEL LOCATEDONORNOMORETHAN1M(3 FT)FROM THE SWITCH THATINCLUDESTHEFOLLOWING: 1. 2. MINIMUM OF 31/2"x10 1/2" FONT:3/8" AC AND DC DISCONNECTS 1.PLACE ONALL ACAND DC DISCONNECTS 2.CODE REFERENCE:NEC 690.13(B) 3.MINIMUMOF 1"x 101/2" 4.FONT:3/8" 5.WHITELETTERSONA REDBACKGROUND. SCALE:1/4"=1'-0"SCALE:1/4"=1'-0" 1.CODEREFERENCE:NEC690.13(C) 2.USEONNON-LOAD BREAKRATED DISCONNECTION. 3.MINIMUMOF 1"x6" 4.FONT:3/8"AND .8 WIDTH FACTOR 5.WHITELETTERS ON AREDBACKGROUND. DC DISCONNECTS 1. 2. VERIFYWHICH PLACARD IS REQUIRED WITH AHJ. 3. MINIMUMOF 1"x 4" FONT:3/8"AND .8WIDTHFACTOR SWITCHBOARDS SCALE:1/2"=1'-0" INVERTER # 1 1.USE PLACARD"INVERTER #1"WHENMORE THAN 1INVERTER IS USED.NUMBERACCORDING TO THREELINE DIAGRAM ANDCALCULATIONS. 2.MINIMUMOF 1"x 4" 3.FONT:3/8" 4.WHITE LETTERSONA RED BACKGROUND. USE PLACARD "[AC][DC]DISCONNECT #1"WHENMORETHAN ONE DISCONNECT IS USED.NUMBERACCORDINGTOTHREELINEDIAGRAM ANDCALCULATIONS. SCALE:1/4"=1'-0"MAIN SERVICE PANEL 1.COMBINATION PLACARDSMAYBEUSEDINPLACE OFMULTIPLEPLACARDSFOR THE SAME DEVICE.ALLINFORMATIONFROMTHEMULTIPLEPLACARDSMUSTBEPRESENT. 2.BLACK LETTERSWITH YELLOW BACKGROUNDMAY BEUSEDINPLACEOF THE STANDARDWHITE LETTERSWITH REDBACKGROUND WITH AHJ APPROVAL. 3.ALL INTERIOR AND EXTERIORDC CONDUIT,ENCLOSURES,RACEWAYS,CABLE ASSEMBLIES,JUNCTION BOXES,COMBINERBOXESAND DISCONNECTSAREMARKED.(NEC690.31[G],NEC690.13 &690.53) 4.THEMARKINGS ONTHECONDUITS,RACEWAYS ANDCABLEASSEMBLIES AREEVERY10 FEET,WITHIN ONE FOOT OF ALLTURNS OR BENDS AND WITHINONE FOOTABOVE ANDBELOWALLPENETRATIONS OFROOF/CEILING ASSEMBLIES,WALLS ANDBARRIERS.(IFC 605.11.1.4,NEC 690.31[G][3]) 5.WHERE PV CIRCUITS ARE EMBEDDEDINBUILT-UP,LAMINATEOR MEMBRANE ROOFINGMATERIALS IN ROOF AREAS NOTCOVERED BYPV MODULES ANDASSOCIATED EQUIPMENT,THELOCATION OFCIRCUITS SHALLBE CLEARLY MARKED. 6.REQUIREDLABELSSHALLBEPERMANENT ANDSUITABLEFORTHEENVIRONMENT.MATERIALSUSEDFOR MARKING MUST BEWEATHERRESISTANT.UL STANDARDIS RECOMMENDEDTODETERMINE WEATHER RATING.ULLISTING OFMARKINGS ISNOTREQUIRED.SEEUL LABELINGSYSTEM 969 (UL969) 7.MARKING CONTENT AND FORMAT: 7.1.ARIALORSIMILAR FONT,NON-BOLD. 7.2.MINIMUM 3/8"LETTERHEIGHT FOR HEADERS. 7.3.MINIMUM 1/16"LETTER HEIGHTFOR DATA7.4.CONTRASTING BACKGROUNDAND LETTERING. 7.5.ALL CAPITALLETTERS. 7.6.CONTRASTING SPACE BETWEEN ROWSOF TEXT 7.7.DIMENSIONSOF PLACARDSAREAPPROXIMATE.MAYBE REDUCED AND/OR INCREASED TOUL APPROVEDMANUFACTURED PRODUCT CODE ABBREVIATIONS:NATIONALELECTRICALCODE(NEC)INTERNATIONALBUILDING CODE(IBC)INTERNATIONALRESIDENTIAL CODE (IRC)INTERNATIONALFIRECODE(IFC)UNDERWRITERS LABORATORY(UL) DO NOT DISCONNECT UNDER LOAD RAPID SHUTDOWN SWITCH RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM THELABEL SHALLBE REFLECTIVEWITHALL LETTERSCAPITALIZEDANDHAVINGAMINIMUMHEIGHTOF9.5MM (3⁄8 IN.),IN WHITE ON RED BACKGROUND. 2. 1/4"=1'-0"SCALE: 2CODE REFERENCE:NEC 690.56(C)(1)(a) 3TITLE:MIN.3/8"BLACKCHARACTERSONYELLOWBACKGROUND,REMAININGCHARACTERSMIN.3/16"INBLACKONWHITEBACKGROUND. 1LOCATE NO MORETHAN 1mFROMTHESERVICEDISCONNTMEANSTOWHICHTHEPVSYSTEMSARECONNECTEDANDSHALLINDICATETHELOCATIONOFALLIDENTIFIEDRAPIDSHUTDOWNSWITCHESIFNOTATTHESAMELOCATION. SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE “OFF” POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. SOLAR ELECTRIC PV PANELS ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE AND LOADSIDES MAY BE ENGERGIZED IN THEOPEN POSITION ! THE DISCONNECTION OF THEGROUNDED CONDUCTOR(S) MAYRESULT IN OVERVOLTAGE ON THEEQUIPMENT ! PHOTOVOLTAIC DC DISCONNECT PHOTOVOLTAIC AC DISCONNECT WARNINGARC FLASH HAZARDAPPROPRIATE PPE REQUIREDFAILURE TO COMPLY CAN RESULT INDEATH OR INJURYREFER TO NFPA 70E ! WARNINGWARNING 2017NEC11132021KN 5.WARNING LABEL ISWHITEAND ORANGE 3.WARNINGLABEL IS WHITE ANDORANGE 4.WARNINGLABEL IS WHITE ANDORANGE 5.DATA COLLECTED FROMAS-BUILT INFO,PRIORTOPTO,BY OTHERS.RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSSTANDARDPLACARDS1.ONLYFORUNGROUNDEDSYSTEMS. 2.PLACED ONALL ENCLOSURESWITH UNGROUNDEDCIRCUITS ORDEVICES WHICH ARE ENERGIZEDAND MAY BE EXPOSED DURINGSERVICE. 3.MINIMUM OF3"x10 1/2" 4.FONT:3/8" ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOADSIDES MAY BE ENGERGIZED IN THEOPEN POSITION !WARNING DC VOLTAGE IS ALWAYS PRESENTWHEN SOLAR MODULES AREEXPOSED TO SUNLIGHT 5.WARNING LABEL ISWHITEAND ORANGE 10 11SCALE:1/2"=1'-0"INVERTER(S) 1. 2. USE PLACARD "COMBINER#1"WHEN MORETHAN1DCCOMBINER ISUSED.NUMBERACCORDING TOTHREE LINEDIAGRAMAND CALCULATIONS. 3. MINIMUMOF 1"x 4" 4. FONT:3/8"AND.75 TO .8WIDTHFACTOR WHITE LETTERSON A RED BACKGROUND. DC COMBINER BOX SCALE:1/2"=1'-0" ENGINEERING STAMP (if appl.)P-001QTY 22 Q-Cells Q.PEAK DUO BLK ML-G10+ 400 MODULES, QTY 22 Enphase IQ7PLUS-72-2-US (240V) MICRO INVERTER Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT UTILITY METER &SERVICE PANEL CUSTOMER OWNEDGENERATION METER AC DISCO AC COMBINER SOLAR ARRAYON ROOF TOP UTILITY METER &SERVICE PANEL CUSTOMER OWNED GENERATION METER AC DISCO AC COMBINER SOLAR ARRAYON ROOF TOP SHEET NOTES 1.COMBINATIONPLACARDS MAY BE USED IN PLACEOF MULTIPLEPLACARDSFORTHESAMEDEVICE.ALL INFORMATION FROMTHEMULTIPLE PLACARDSMUSTBE PRESENT. 2. 3. 4. BLACKLETTERS WITHYELLOW BACKGROUND MAYBE USEDINPLACE OFTHESTANDARD WHITE LETTERSWITH REDBACKGROUND WITHAHJ APPROVAL. ALL INTERIOR AND EXTERIORDC CONDUIT,ENCLOSURES,RACEWAYS,CABLEASSEMBLIES,JUNCTIONBOXES,COMBINERBOXES ANDDISCONNECTS ARE MARKED.(NEC 690.31[G],NEC 690.53) REQUIRED LABELS SHALLBEPERMANENT ANDSUITABLEFORTHEENVIRONMENT.MATERIALSUSED FOR MARKING MUST BEWEATHER RESISTANT.ULSTANDARD ISRECOMMENDED TODETERMINE WEATHER RATING.ULLISTING OFMARKINGS ISNOTREQUIRED.SEEULLABELINGSYSTEM 969 (UL 969) 5.MARKING CONTENT ANDFORMAT: 5.1.ARIAL OR SIMILAR FONT,NON-BOLD.5.2.MINIMUM3/8"LETTER HEIGHTFORHEADERS. 5.3.MINIMUM1/16"LETTERHEIGHT FOR DATA 5.4.CONTRASTINGBACKGROUND ANDLETTERING. 5.5.ALL CAPITALLETTERS.5.6.CONTRASTINGSPACE BETWEENROWS OFTEXT 5.7.DIMENSIONS OFPLACARDS ARE APPROXIMATE.MAY BEREDUCEDAND/ORINCREASEDTO UL APPROVEDMANUFACTUREDPRODUCT 6.ANSIZ535.4PRODUCT SAFETYSIGNSAND LABELS:THISINFORMATIONALNOTEANDITSREQUIREMENTSFORPLACARDSMAYBEUSEDWITHPRIORAPPROVALOFTHEAHJ.MOSTNOTABLEDIFFERENCESISCOLOROFPLACARDSANDUSEOFHANDWRITTENVALUESWITHINDUSTRIALMARKERSONSTANDARD PLACARDS WHERE THEVALUE MAY CHANGEAT AFUTUREDATE.I.E.ADDINGMODULES ATA FUTURE DATE,ORSTANDARD PLACARDMANUFACTURERINSTALLED ONELECTRICAL COMPONENT.AHJAPPROVALREQUIRED.(SEENOTE #1 FOR INDIVIDUAL PLACARDS) 1 2 3 4 SCALE:1/4"=1'-0" MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAMELOCATION) SCALE:1/4"=1'-0"UTILITY METER,SERVICE PANEL,SUB-PANELACDISCONNECT,AC SUB-PANEL 1.PLACARD PLACED ONEACH SOLAR SYSTEMDISCONNECTINGCOMPONENT. 2.VALUESMUST MATCHEQUIPMENTCALCULATIONS.SEESHEET "E-001/ACDISCONNECT[#]" 3.CODEREFERENCE:NEC 690.54 4.MINIMUM OF11/2"x81/2"(TOP),13/4"x61/2"(BOT) 5.FONT:3/8"HEADER,3/16"DATA 6.WHITELETTERS ONA REDBACKGROUND. AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS WARNING DUAL POWER SOURCES RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS 1.(#1)PLACARDPLACED ATMAINUTILITYSERVICEDISCONNECT/BREAKERAND PV SYSTEMSUPPLYBREAKERATPOINTOFINTERCONNECTION.(#2&#3)PLACARD(S)REQUIREDWITH #1PLACARD WHEN UTILITY SERVICE ANDPV SYSTEMDISCONNECTARENOT LOCATED NEXT TOEACH OTHER.MAPPLACARDREQUIRED AS SPECIFIED. 2.VALUES MUST MATCH EQUIPMENT CALCULATIONS. 2.1.VALUESWILL MATCH LOAD CENTEROR SUB-PANEL VALUES IFINSTALLED AFTERINVERTERS.IFAC CONNECTION TOSERVICEPANEL COMESFROM INVERTERS;SEESHEET"E-001 /STRING INVERTER[#]SPECIFICATIONS".2.1.1.INVERTERS ARE PARALLELCONNECTIONS.2.1.2."RATEDAC OUTPUT CURRENT"WILL BE THE SUM OF THEINVERTERS 2.1.3."AC NORMAL OPERATINGVOLTAGE"WILLBE THE NAME PLATE RATINGOF THEINVERTER 3.CODE REFERENCE:NEC 690.54,NEC 705.12(B)(3) 4.MINIMUMOF 2"x 6 1/2"(#1),VARIES (#2 &#3) 5.FONT:3/8"HEADER,3/16"DATA(#1),1/4"(#2 &#3) 6.WHITE LETTERSONA RED BACKGROUND. SCALE:1/2"=1'-0"5 CAUTION WARNING ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 1.PLACARD PLACED AT ELECTRICAL SERVICE ANDATTHEPVINVERTER ANDPV DISCONNECTS IF NOT AT THE SAME LOCATION. 2.MAP PLACARD PROVIDES ADIRECTORYOF THE SERVICEDISCONNECTING MEANS ANDPHOTOVOLTAICSYSTEMDISCONNECTION MEANS. 3.CODE REFERENCE:NEC 690.56(A)(B),705.10 4.WHITELETTERSONA REDBACKGROUND. 5.MINIMUM OF73/4"x5" 6.FONT:3/4""CAUTION",1/4""WARNING",3/16"HEADER,1/8"DATA ANDNOTES 7.PLACARD WILLBEPLACED ADJACENTTOTHE MAIN SERVICEDISCONNECTINALOCATIONCLEARLYVISIBLEFROMWHERETHE DISCONNECT IS OPERATED.(CFC605.11.1.3&CRCR331.2.3) MAP PLACARD:MAIN SERVICE PANEL AND PV INVERTER (IF NOT SAMELOCATION)SCALE:1/2"=1'-0" CAUTION 1.PLACARD PLACED AT ELECTRICAL SERVICE ANDATTHEPVINVERTERANDPVDISCONNECTSIFNOTATTHESAMELOCATION. 2.MAP PLACARD PROVIDESA DIRECTORYOF THESERVICEDISCONNECTINGMEANSANDPHOTOVOLTAICSYSTEM DISCONNECTION MEANS. 3.CODE REFERENCE:NEC 690.56(A)(B),705.10 4.WHITELETTERSONA REDBACKGROUND. 5.MINIMUMOF 61/2"x 61/2" 6.FONT:3/4""CAUTION",1/4"HEADER,1/8"DATAANDNOTES 7.PLACARD WILL BE PLACED ADJACENTTO THEMAINSERVICEDISCONNECTINA LOCATIONCLEARLYVISIBLE FROMWHERE THE DISCONNECT ISOPERATED.(CFC 605.11.1.3 &CRCR331.2.3) AC COMBINER DYNAMICPLACARDSAC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING BUILDING CONTAINS TWO SOURCES OF POWER: UTILITY, SOLAR PV UTILITY SERVICE DISCONNECT LOCATED BELOW. SOLAR PV SYSTEM DISCONNECT LOCATED [N/E/S/W] WALL OF BUILDING SCALE:1/2"=1'-0" 1. 2. USEPLACARD"COMBINER #1"WHENMORE THAN 1 ACCOMBINER ISUSED.NUMBERACCORDINGTO THREE LINEDIAGRAM AND CALCULATIONS. 3. MINIMUM OF 1"x 4" 4. FONT:3/8"AND .75TO .8 WIDTH FACTORMINIMUM. 5. WHITELETTERS ONAREDBACKGROUND. PLACARDSMAYBE COMBINED TOGETHER.I.E."ACCOMBINER BOX#1".MINIMUMREQUIREMENTSLISTEDABOVE. AC COMBINER / DISCONNECT #1 AC SUB-PANEL #1 AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE PV SYSTEM AC DISCONNECT AMPS VOLTS PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT AC NORMAL OPERATING VOLTAGE AMPS VOLTS AC COMBINER / DISCONNECT #2 AC SUB-PANEL #2 AC COMBINER / DISCONNECT #3 #1 #2 #3 CODEABBREVIATIONS:NATIONAL ELECTRICAL CODE (NEC)INTERNATIONAL BUILDING CODE(IBC)INTERNATIONAL RESIDENTIALCODE(IRC)INTERNATIONAL FIRE CODE (IFC)UNDERWRITERS LABORATORY(UL) 1.PRIMECONTRACTOR /PERMITAPPLICANT SIGNERIS RESPONSIBLE FORTHE DESIGNANDSPECIFICATIONSOF THE PHOTOVOLTAIC SYSTEMINSTALLATION.PRIME CONTRACTOR/PERMITAPPLICANT SIGNER WILLBERESPONSIBLEFORCOLLECTIONOF EXISTING ONSITE INFORMATIONREQUIREMENTS TO DESIGN,SPECIFY,ANDINSTALLTHEEXTERIORMOUNTEDPORTIONOFTHEPHOTOVOLTAICSYSTEM DETAILED IN THISDOCUMENT. 2.ADVANCEDSOLAR SOLUTIONS,INC ISRESPONSIBLEFORAPPLYINGSUPPLIEDINFORMATION INTO ASETOFPERMITDRAWINGS.ANY CHANGESTODRAWINGSARESUBJECTTOCONTRACTCONDITIONSBETWEENTHECLIENTANDADVANCEDSOLARSOLUTIONS,INC.INACCORDANCEWITHTHEREQUIREMENTSOF THEAHJ. RESPONSIBILITY NOTES RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSNN 26.62 240 26.62 240 26.62 240 26.62 240 26.62240 P-002Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT IMTSIIQEMIE EIMEREIM EQEMEPPMQTPMIMREPPEMSRTSIMPI achievingthehighestsystemefciency. ESIRTEI-7IQI-ER -MSMRIIMRIEIMIRTEI -RSRTEI-EIERIRTEI Enlighten™monitoringandanalysissoftware. -7IMIMSMRIIIIRIIPMEMPM EREISTIMSIRIEMSRER RISSIEQMPPMSRSSTSISRIMR IREPMRRTEISTSMIERMRPIEMR warrantyofupto25years. EI E MMII 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ EE7IIEIMMIIIMSR-7 )EWXS-RWXEPP 0MLXIMLXERHWMQTPI *EWXIVMRWXEPPEXMSRMXLMQTVSIHPMLXIVXSMVIGEFPMR &YMPXMRVETMHWLYXHSRGSQTPMERX2) 4VSHYGXMIERH6IPMEFPI 3TXMQMIHSVLMLTSIVIHGIPPLEPGIPPERHGIPPLEPGIPPQSHYPIW 1SVIXLEREQMPPMSRLSYVWSXIWXMR PEWW--HSYFPIMRWYPEXIHIRGPSWYVI 90PMWXIH 7QEVX+VMH6IEH SQTPMIWMXLEHERGIHVMHWYTTSVXSPXEIERHVIUYIRGVMHIXLVSYLVIUYMVIQIRXW 6IQSXIPYTHEXIWXSVIWTSRHXSGLERMR VMHVIUYMVIQIRXW • Congurableforvaryinggridproles 1IIXW%6YPI907% 8LI-51MGVSMWVIUYMVIHXSWYTTSVXGIPPLEPGIPPQSHYPIW 2SIRSVGIH(%VEXMS7IIXLIGSQTEXMFMPMXGEPGYPEXSVEXLXXTWIRTLEWIGSQIRYWWYTTSVXQSHYPIGSQTEXMFMPMX2SQMREPSPXEIVERIGERFIIXIRHIHFISRHRSQMREPMVIUYMVIHFXLIYXMPMX0MQMXWQEEV6IIVXSPSGEPVIUYMVIQIRXWXSHIMRIXLIRYQFIVSQMGVSMRIVXIVWTIVFVERGLMRSYVEVIE 8SPIEVRQSVIEFSYX)RTLEWISIVMRWMWMXIISQ ©2020EnphaseEnergy.Allrightsreserved.Enphase,theEnphaselogo,EnphaseIQ7,EnphaseIQ7+,EnphaseIQBattery, EnphaseEnlighten,EnphaseIQEnvoy,andothertrademarksorservicenamesarethetrademarksofEnphaseEnergy,Inc.Datasubjecttochange.2020-08-12 -2((-7 -77 SQQSRPYWIHQSHYPITEMVMRWz ;;;; 1SHYPIGSQTEXMFMPMXGIPPLEPGIPP4:QSHYPIWSRPGIPPLEPGIPPERHGIPPLEPGIPP4:QSHYPIW 1EMQYQMRTYX(SPXEI :: 4IEOTSIVXVEGOMRSPXEI :::: 3TIVEXMRVERI :::: 1MR1EWXEVXSPXEI :::: 1E(WLSVXGMVGYMXGYVVIRXQSHYPI-WG%% 3IVSPXEIGPEWW(TSVX ---- (TSVXFEGOIIHGYVVIRX %% PVarrayconguration YRVSYRHIHEVVE2SEHHMXMSREP(WMHITVSXIGXMSRVIUYMVIH%WMHITVSXIGXMSRVIUYMVIWQE%TIVFVERGLGMVGYMX (-MVSMIVIV -MVSMIVIV 4IEOSYXTYXTSIV :%:% 1EMQYQGSRXMRYSYWSYXTYXTSIV :%:% 2SQMREP00SPXEIVERIs :::::::: 1EMQYQGSRXMRYSYWSYXTYXGYVVIRX %:%:%:%: 2SQMREPVIUYIRG,, )XIRHIHVIUYIRGVERI ,, %WLSVXGMVGYMXEYPXGYVVIRXSIVGGPIW %VQW %VQW 1EMQYQYRMXWTIV%00FVERGLGMVGYMXt :%:%:%:% 3IVSPXEIGPEWW%TSVX ------ %TSVXFEGOIIHGYVVIRX Q%Q% 4SIVEGXSVWIXXMR 4SIVEGXSVEHNYWXEFPIPIEHMRPEMRPIEHMRPEMR )--)2 Peakefciency CECweightedefciency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kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSINVERTER CUT SHEET R-101Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT snapnrack.com Ultra Rail Industry leading Wire Management Solutions Single Tool Installation Mounts available for all roof types All SnapNrack Module Clamps & Accessories are compatible with both raiil profi les Start Installing Ultra Rail Today UR-40 UR-60 The Ultimate Value in Rooftop Solar Solar Mounting Solutions © 2016 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack_Ultra Rail Sales Brochure_v.1.4 SnapNrack Solar Mounting Solutions are engineered to optimize material use and labor resources and improve overall installation quality and safety. Quality. Innovative. Superior. Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install • Industry best wire management o ering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 Standard © 2019 by SnapNrack Solar Mounting Solutions. All rights reserved 877-732-2860 www.snapnrack.com contact@snapnrack.com SnapNrack Ultra Rail System A sleek, straightforward rail solution for mounting solar modules on all roof types. Ultra Rail features two rail profi les; UR-40 is a lightweight rail profi le that is suitable for most geographic regions and maintains all the great features of SnapNrack rail, while UR-60 is a heavier duty rail profi le that provides a larger rail channel and increased span capabilities. Both are compatible with all existing mounts, module clamps, and accessories for ease of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Heavy Duty UR-60 Rail • UR-60 rail profi le provides increased span capabilities for high wind speeds and snow loads • Taller, stronger rail profi le includes profi le- specifi c rail splice and end cap • All existing mounts, module clamps, and accessories are retained for the same great install experience RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-102Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-40RAIL 232-02449,232-02450,232-02451 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 5.85 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 144 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-40 RAIL PROPERTIES SKU FINISH232-02449 MILL 232-02450 CLEAR 232-02451 BLACK 1.624 1.500 CENTROID .750 .832 .792 SECTION PROPERTIES A 0.357 in² Ixx 0.125 in⁴ Iyy 0.132 in⁴ Sx (TOP)0.150 in³ Sx (BOT)0.158 in³ Sy (LEFT)0.175 in³ Sy (RIGHT)0.175 in³ DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-40 SPLICE 242-01213, 242-01214 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL N/A N/A 12 LB-FT UL 2703, FILE E359313 0.52 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM SNAPNRACK, UR-40 SPLICE TAPPED PRC, CLEAR11 SNAPNRACK, UR-40 SPLICE THRU PRC, CLEAR12 SNAPNRACK, SNAPLINK BONDING CLIP, TYPE 2, STEEL23 BOLT, FLANGE, SERRATED, 5/16IN-18 X 1-3/4IN, SS14 1 2 4 3 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-103Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT DESCRIPTION: PARTNUMBER(S): DRAWNBY: SNAPNRACK,UR-60RAIL 232-02481,232-02482,232-02483 mwatkins Solar Mounting Solutions THEINFORMATIONINTHISDRAWINGISCONFIDENTIALANDPROPRIETARY.ANYREPRODUCTION,DISCLOSURE,ORUSETHEREOFISPROHIBITEDWITHOUTTHEWRITTENCONSENTOFSUNRUNSOUTHLLC. 595MARKETSTREET,29THFLOOR●SANFRANCISCO,CA94105USAPHONE(415)580-6900●FAX(415)580-6902A REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM N/A N/A N/A LB-FT UL 2703, FILE E359313 8.46 OPTIONS: CLEAR / BLACK ANODIZED MILL FINISH BUNDLES OF 120 BOXES OF 8 ALL DIMENSIONS IN INCHES UR-60 RAIL PROPERTIES SKU FINISH232-02481 MILL232-02482 CLEAR 232-02483 BLACK CENTROID .750 1.211 1.039 SECTION PROPERTIES A 0.515 in² Ixx 0.327 in⁴ Iyy 0.181 in⁴ Sx (TOP)0.270 in³ Sx (BOT)0.315 in³ Sy (LEFT)0.242 in³ Sy (RIGHT)0.242 in³ 2.250 1.500 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, UR-60 SPLICE 242-01270, 242-01271 mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL FULL UR-60 RAIL CAPACITY N/A 12 LB-FT UL 2703, FILE E359313 0.71 OPTIONS: CLEAR / BLACK ANODIZED PARTS LIST DESCRIPTIONQTYITEM BOLT, FLANGE, 5/16IN-18 X 3/4IN, CLEAR, SS11 SNAPNRACK, UR-60 SPLICE, SLEEVE, CLEAR / BLACK12 SNAPNRACK, O-RING13 SNAPNRACK, UR-60 SPLICE, BONDING BRIDGE14 1 4 3 2 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-104Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT snapnrack.com 51 System Bonding Methods Grounding Specifications RAIL CHANNEL NUT MODULEFRAME MID CLAMP ASSEMBLY SS BONDING PIN NOTE: SnapNrack Mid Clamp SnapNrack Adjustable End Clamp SnapNrack UR-40 Rail Splice SnapNrack UR-60 Rail Splice q   SnapNrack module clamps contain a SnapNrack Channel Nut with integral bonding clips or pins in assembly to properly bond the system (except Universal End Clamps). Note: SnapNrack Ground Lug Assembly SNAPNRACKULTRA SERIES RAIL 5/16"-18 X 1" BOLT S.S.WITH SPLIT LOCK WASHER S.S. SNAPNRACK GROUNDLUG, 6-12 AWG SNAPNRACK BONDING CHANNEL NUT COPPER WIRE, TYP. SS BONDING CLIP(2 TOTAL)RAIL SPLICEASSEMBLY SnapNrack Ultra Rail Splices contain integral bonding clips in assembly to properly bond the system. Note:  RAIL SPLICEASSEMBLY SS BONDING PIN(2 TOTAL) snapnrack.com 52 Grounding Specifications Ground Path Details Ilsco Lay-in Lug Assembly SNAPNRACKULTRA SERIES RAIL #10 BOLT SS ILSCO GBL-4DBT GROUND LUG #10 NUT SSWITH STAR WASHER COPPER WIRE, TYP. GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMP M = MIDCLAMP X = X-END CLAMPU = UNIVERSAL END CLAMP TO EGC RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-105Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT snapnrack.com 53 Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U TO EGC MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMP U = UNIVERSAL END CLAMP ENPHASEMICRO-INVERTER GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDINGCONDUCTOR M M M M M M M M X X U U U U U U X X U U MOUNT M MODULE CLAMPM = MIDCLAMPX = X-END CLAMPU = UNIVERSAL END CLAMP SOLAREDGEOPTIMIZER TO EGC TO EGC Ground Path Details - Enphase Ground Path Details - SolarEdge snapnrack.com 54 INSTALLATION INSTRUCTIONS - SNAPNRACK GROUND LUG 1) Snap the SnapNrack Ground Lug into the rail channel on one rail per module row. 2) Place grounding conductor into slot underneath split ring washer. SnapNrack Ground Lug may be used in side or top channel, and may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. Install Note: SnapNrack Ground Lug only Listed for use with 6-12 AWG solid copper conductor. Install Note: 3) Tighten hardware to 16 ft-lbs. Grounding Specifications INSTALLATION INSTRUCTIONS - ILSCO LAY-IN LUG 1) Drill and deburr a 1/4” hole in the back side of the rail for the Ilsco lug to attach to, place the bolt through the hole, and attach the lug assembly on one rail per module row. 2) Place grounding conductor into slot. Torque rail connection to 35 in-lbs. Install Note: Torque set screw to 20 in-lbs for #10- #14 solid and stranded copper, 25 in-lbs for #8 stranded copper, and 35 in-lbs for #4-#6 stranded copper. Install Note: 3) Tighten set screw per Ilsco’s recommendation (see below). • System has been evaluated to a maximum overcurrent device (OCD) protection level of 20 Amps. • Universal End Clamp (UEC) does not bond module to rail. Be sure to separately ground any modules that are only secured by UECs, especially during servicing. • SnapNrack recommends that bare copper never come into contact with aluminum. • SnapNrack Ground Lug: torque bolt to 16 ft-lbs. The Ground Lug may be used in side or top channel. It may be rotated 90 degrees relative to slot to facilitate running copper across top of rails. • Grounding with a standard Ilsco GBL-4DBT Lug is a listed alternate and requires drilling of a hole in the rail.• Ilsco hardware connection to rail: 5 ft-lbs. Torque for lug set screw: #10-#14 solid and stranded copper- 20 in-lbs, #8 stranded copper- 25 in-lbs, #4-#6 stranded copper- 35 in-lbs. Note:RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-106Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT snapnrack.com 55 Ground Path Details - DynoBond Grounding Specifications GROUND PATH RAIL RAIL SPLICE GROUND LUG EQUIPMENT GROUNDING CONDUCTOR(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)(+)(-)M M M M M M M M E E TO EGC MOUNT M MODULE CLAMPM = MIDCLAMP E = END CLAMP(+)(-)E E M M M M E E E E DYNORAXX DYNOBOND R/C (QIMS2), DynoRaxx (E357716) photovoltaic bonding jumper cat. no. DynoBond is an optional component that may be used with this system. The DynoBond jumper has been evaluated to provide module to module bonding. The DynoBond device attaches to the frame flange of adjacent modules. 1/953 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-107Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT SnapNrack 775 Fiero Lane,Ste.200 SanLuis Obispo,CA93401 TEL:(877)732-2860 Attn.:SnapNrack-EngineeringDepartment Subject:Engineering Certification for the State of Massachusetts BuildingCodes:1.ASCE/SEI 7-10,Minimum Design Loads for Buildings and OtherStructures,byAmerican SocietyofCivilEngineers 2.2015InternationalBuildingCode,by International Code Council,Inc. 3.2015InternationalResidentialCode,by International Code Council,Inc. 4.AC428,AcceptanceCriteriafor ModularFramingSystemsUsedtoSupport Photovoltaic (PV) Panels,November1,2012by ICC-ES 5.Aluminum Design Manual 2015,by The Aluminum Association,Inc. 6.ANSI/AWC NDS-2015,NationalDesignSpecification for Wood Construction,by theAmerican Wood Council Design Criteria:Risk CategoryII SeismicDesign Category =A -E Basic Wind Speed (ultimate)perASCE7-10:up to 190 mph Ground Snow Load =0 to 120(psf) Thisletter certifiesthat theloading criteria and designbasis forthe SnapNrack UltraRailRacking SystemwithUR-40Rail Span Tables are in compliancewiththe above codes. If you have anyquestions on theabove,do not hesitate to call. Preparedby: PZSE, Inc. – Structural Engineers Roseville,CA August 6,2019 PZSE, Inc. – Structural Engineers has provided engineering and span tables for the SnapNrack Ultra Rail Racking System with UR- 40 Rail,as presented inPZSE Report #2017-03227.11,"EngineeringCertification and SpanTablesfor the SnapNrackUltra Rail Solar PhotovoltaicRackingSystem".Allinformation,data,and analysis thereinare basedon,and complywith,the following building codes and typicalspecifications: Re: Report # 2017-03227.11 – SnapNrack Ultra Rail Solar Photovoltaic Racking System with UR-40 Rail RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSRACKING & RAIL CUT SHEET R-108Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: MATERIALS: DESIGN LOAD (LBS): ULTIMATE LOAD (LBS): TORQUE SPECIFICATION: CERTIFICATION: WEIGHT (LBS): 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 405 UP, 788 DOWN, 236 SIDE 2006 UP, 4000 DOWN, 1070 SIDE 12 LB-FT UL 2703, FILE E359313 0.80 PARTS LIST DESCRIPTIONPART NUMBERQTYITEM SNAPNRACK, UMBRELLA LAG, TYPE 3, 4IN, SS242-9226611 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER / BLACK242-01219, 242-0122012 SNAPNRACK, COMP FLASHING, 9IN X 12IN, SILVER / BLACK ALUM232-01375, 232-0137613 3 1 2 2 DESCRIPTION: PART NUMBER(S): DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT SEE BELOW mwatkins Solar Mounting Solutions THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANYREPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THEWRITTEN CONSENT OF SUNRUN SOUTH LLC. 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USAPHONE (415) 580-6900 ● FAX (415) 580-6902B REVISION: ALL DIMENSIONS IN INCHES 11.75 3.25 8.75 .45 6.75 n1.00 4.20 .30 3.25 n1.00 1.00 SLOT 1.50 2.78 1.78 1.50 .38 .30 1.37 1.62 UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK COMP FLASHING PROPERTIES SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM n.35 1.80 105°RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSSTANCHION - ROOF ATTACHMENT CUT SHEET R-109Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT pe.eaton.com General Duty Non-Fusible Safety Switch DG222URB UPC:782113144238 Dimensions: Height: 7.5 IN Length: 6.41 IN Width: 8.4 IN Weight:9 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: Type: General Duty/Non-Fusible Amperage Rating: 60A Enclosure: NEMA 3R Enclosure Material: Painted galvanized steel Fuse Configuration: Non-fusible Number Of Poles: Two-pole Number Of Wires: Two-wire Product Category: General Duty Safety Switch Voltage Rating: 240V Supporting documents: Eatons Volume 2-Commercial Distribution Eaton Specification Sheet - DG222URB Certifications: UL Listed Product compliance: No Data______________________________________________________________________ © 2016 Eaton. All rights reserved. V2-T1-26 Volume 2—Commercial Distribution CA08100003E—May 2018 www.eaton.com 1 1.1 Switching Devices Safety Switches All general-duty switches above 100A and all heavy-duty switches incorporate these K-Series switch design features. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not provided on general-duty switches, but available as a field kit or factory installed Clear Line Shield Clearly Visible Handle ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Triple Padlocking Capability ●Personnel safety feature because the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Additional Locking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Interlocking Mechanism ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Tangential Knockouts ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Bolt-On Hub Kits ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Seismic Qualifications ●General-duty switches exceed the requirements of Uniform Building Code (UBC) and California Code Title 24 OSP-0011-10, OSP-0012-10 RELEASEREVDATENAMEAPNADDRESSADDRESS kW PHOTOVOLTAIC PLANSEQUIP.CUTSHEETSAC DISCONNECT CUT SHEET R-110Valley Solar21134A340 Riverside DrFlorence, MA 01062(413) 584-88448.800Bunk, Brian53 Meadow StNorthampton, MA 0106212/03/2021SUBMIT FOR PERMIT